DELUXE 13 SEER
550A
AIR CONDITIONER
WITH PURON® REFRIGERANT
Sizes 024 thru 060
on production of most other refrigerants which has scheduled
reductions beginning in 2004. The resulting cap in production
ultimately results in a complete ban on many other refrigerants
in new equipment by the year 2010. These changes required by
federal law, mean the supply of other refrigerants may be limited
in the near future making Puron refrigerant the correct choice
when considering long term serviceability.
Highly Reliable Performance—Is delivered through the supe-
rior design of the system and componentry. The reliability of
the 550A models has been proven to provide the lowest inci-
dence of warranty service of any product in the Bryant family
in the past three years of service. Long term reliability is
assured through the use of both high and low pressure
switches which will not allow the system to operate in the
event of a significant change in operating pressure. In doing
this, the system is protected from damage if an unusual condi-
tion arises. Finally, Bryant includes a special liquid line filter
drier designed to trap moisture and contaminants which could
otherwise shorten the life of the system.
TM
Bryant’s AeroQuiet System—Is one of the most sought after
features of the 550A family. Extremely low operating sound is the
result of special attention to the air moving through the outdoor
unit, a specially designed sound enclosure surrounding the com-
pressor, and an exclusive laminated plate beneath the compres-
sor to eliminate sound transmission to the rest of the system.
Bryant’s Air Conditioners with Puron® refrigerant provide a col-
lection of features unmatched by any other family of equipment.
The 550A family has been designed utilizing Bryant’s Puron
refrigerant. The environmentally sound refrigerant allows you to
make a responsible decision in the protection of the earth’s
ozone layer. Bryant’s 550A system meets the Energy Star®
guidelines for energy efficiency.
Application Versatility—Bryant’s systems utilizing Puron
refrigerant have the same application guidelines as other sys-
tems. Applications which include long line sets (50 to 175 ft) or
applications which require the system to operate at low outdoor
temperatures (below 55°F) are approved under Bryant’s stan-
dard guidelines.
FEATURES
Puron Environmentally Sound Refrigerant—Is Bryant’s
refrigerant designed to help protect the environment. Puron is
an HFC refrigerant which does not contain chlorine that can
harm the ozone layer. The most important advantage of Puron
refrigerant is that it has not been banned in future air condition-
ing systems as the traditional refrigerant R-22 has been. Puron
refrigerant is in service in thousands of systems proving highly
reliable, environmentally sound performance.
Bryant’s Evolution™ Controls—These industry-leading con-
trols, when installed with Bryant’s Perfect Humidity™ variable-
speed furnaces or fan coils, provide the homeowner with:
–unparalleled control of temperature, humidity, indoor air quality,
and zoning
Bryant Coils and Fan Coils to Complete the System—Bryant
specially designs both the outdoor product and indoor coil prod-
ucts to operate with assured reliability and performance. A wide
range of indoor coil options are listed in the ratings sections of
this publication.
Special Protective Devices—High and low pressure switches
and internal protection in the compressor including temperature
and current sensing overloads prevent operation under poten-
tially damaging circumstances. A special liquid line filter drier
designed to trap nearly 4 times the volume of contaminants of
standard driers provides superior protection from moisture
trapped in the system.
–unprecedented ease of use
–simple operation through on-screen, text-based service
reminders
Optional remote access through telephone or Internet is also
available when combined with a remote connectivity kit.
Electrical Range—208/230v, single phase.
Wide Range of Sizes—Available in six sizes; 2, 2-1/2, 3, 3-1/2,
4, and 5 ton.
Cabinet—Galvanized steel is coated with powder paint to pro-
vide superior long-lasting protection and appearance.
Heavy Duty Inlet Grille—The DuraGuard™ coil protector,
made of a coated steel wire grid with vertical 3/8 in. spacing, is
designed to help protect the coil from inclement weather, van-
dalism, and incidental damage. It provides protection while not
restricting airflow and maintaining ease of coil inspection and
cleaning.
Totally Enclosed Fan Motor—Protected from adverse weather
conditions.
Unit Design—Enhanced copper and aluminum heat transfer
surfaces with vertical air discharge to direct air up and away
from the area.
High Efficiency Performance—Is delivered through a combi-
nation of features including Bryant’s Puron refrigerant, unique
scroll compressor, and advanced heat transfer surfaces. Effi-
ciency ratings are 13 SEER (Seasonal Energy Efficiency
Ratio) with enhanced ratings of up to 14.5 SEER. Sophisti-
cated heat transfer surfaces utilized in Bryant’s 550A design
allow heat to easily be transferred to the outdoor air and
require less energy. The unique scroll compressor found in the
550A design performs quietly and adds to the overall efficiency
of the system. For improved serviceability, all models are
equipped with a compressor terminal plug. Finally, Bryant’s
Puron refrigerant operates more efficiently than ordinary R-22
refrigerant found in other systems. The efficiency levels pro-
vided by the 550A provide end users with lower costs of opera-
tion than traditional air conditioning systems.
External Service Valves—Both service valves are back seating
type valves which are externally located. These unique valves
allow service technicians to evacuate or charge the system in
less time than standard service valves.
Easy Serviceability—Removal of one panel provides access to
both electrical and refrigerant carrying components simplifying
installation and service.
Agency Approvals—550A models are listed with UL (U.S. and
Canada), ARI, and CEC. Special endorsements have also been
awarded these products by Energy Star® which recognizes
energy efficient products.
Limited Warranty—A standard five year warranty on parts
with extended warranty coverage on the compressor for a
total of 10 years. A five year warranty is offered on the out-
door coil. Optional warranties are available through your
Bryant distributor.
Assured Future Service—By utilizing the environmentally
sound refrigerant, Puron, 550A models will remain serviceable
well into the future. The Clean Air Act of 1990 has placed a cap
Form No. PDS 550A.24.10
RECOMMENDED TUBE DIAMETERS
Liquid Tube Diameter (In.)
Vapor Tube Diameter (In.)
UNIT
SIZE
0 to 50 Ft
Tube Length
0 to 50 Ft
Tube Length
Long-Line Applications*
(Maximum Diameter)
Long-Line Applications*
024
5/8
3/4
7/8
7/8
030, 036
042, 048
060
3/8
3/8
7/8
1-1/8
1-1/8
1-1/8
* For tube sets greater than 50 ft horizontal and/or 20 ft vertical differential, consult Residential Split System Application Guideline and Service Manual.
CHECK-FLO-RATER® PISTON
CHARGING SUBCOOLING (TXV-TYPE EXPANSION DEVICE*)
PISTON*
UNIT SIZE–SERIES
024-G
REQUIRED SUBCOOLING (°F)
UNIT SIZE–SERIES
024-G
IDENTIFICATION NO.
10
12
11
12
11
12
55
63
030-F
030-F
036-F, G
042-F
036-F, G
042-F
70
73
048-F
048-F
78
060-H
060-H
TXV
* Must be a Puron® approved hard shutoff TXV.
*Piston listed is for any approved non-capillary tube coil com-
bination. Piston is shipped with outdoor unit and must be
installed in an approved indoor coil.
MODEL NUMBER NOMENCLATURE
550A
N
X
024
000
A
A
AA
Model Number
13 SEER Split-System
Air Conditioner
N/A
Standard Unit
Series A – Original Series
Series B – Second Series, etc.
Electrical Supply
N – 208/230-1-60
Nominal Cooling Capacity
024 – 2 ton 042 – 3.5 ton
Common Unit – U.S.A. Only
030 – 2.5 ton 048 – 4 ton
036 – 3 ton
060 – 5 ton
Heating Size
ISO 9001:2000
As an ENERGY STAR®
partner, Bryant Heating &
Cooling Systems has
determined that this prod-
uct meets the ENERGY
STAR® guidelines for
energy efficiency.
REGISTERED
*
CERTIFICATION APPLIES ONLY
WHEN THE COMPLETE SYSTEM
IS LISTED WITH ARI.
REGISTERED QUALITY SYSTEM
*Refer to the combination ratings in the Product Data Sheet for system combinations meeting ENERGY STAR® efficiency standards.
—3—
SPECIFICATIONS
UNIT SIZE-SERIES
024-G
030-F
036-F/G
Operating Weight (Lb)
214
202
237
ELECTRICAL
Unit Volts—Hertz—Phase
208/230—60—1
Operating Voltage Range*
187—253
14.7
72.5
0.80
19.2
14
Compressor— Rated Load Amps
Locked Rotor Amps
12.8
60.0
0.80
16.8
14
15.4/16.7
83.0/79.0
1.1
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (60°C Copper) AWG†
Min Wire Size (75°C Copper) AWG†
Max Wire Length (Ft) (60°C Copper)‡
Max Wire Length (Ft) (75°C Copper)‡
20.2/22.0
12
14
14
12
46
41
62/57
59/54
44
39
Max Branch Circuit Fuse or
Circuit Breaker Size (Amps)
25
30
30
COMPRESSOR & REFRIGERANT
Compressor— Type
Scroll
Internal Line Break
Puron® (R-410A)
6.00
Temperature & Current Protection
Refrigerant— Type
Amount (Lb)
5.50
6.88
CONDENSER COIL & FAN
Coil Face Area (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP (PSC) & RPM
Volts—Hertz—Phase
12.2
12.2
25—1—2
1/8 & 825
208/230—60—1
2400
15.2
25—1—2
1/8 & 825
25—1—2
1/5 & 825
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Support Feet
2400
2800
KSASF0101AAA
Coastal Filter
KAACF0801MED
KAATD0101TDR
Time Delay Relay
Cycle Protector
KSACY0101AAA
KAACH1201AAA
KSAHS1501AAA
Crankcase Heater
Start Assist—Capacitor/Relay Type
Start Assist—PTC Type
TXV (Hard Shutoff)
Standard
KAACS0201PTC
KSATX0201PUR
KSATX0301PUR
Piston Body
KSAPX0101PIS
KH45LG140 (RCD)
KAAFT0101AAA
KAALS0201LLS
KAAWS0101AAA
KSALA0301410
KSALA0401AAA
HC38GE231 (RCD)
Filter Drier (Suction Line)
Evaporator Freeze Thermostat**
Liquid-Line Solenoid Valve
Winter Start Control**
Low-Ambient Pressure Switch
MotorMaster® Low-Ambient Controller ††
Ball Bearing Fan Motor
Thermidistat™ Control—
Programmable Thermostat with Humidity Control
TSTATBBPRH01-B
TSTATBBPAC01-B
TSTATBBNAC01-C
TSTATBBSAC01
Thermostat—Auto Changeover,
7-Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat—Auto Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Thermostat—Manual Changeover
5-2 Day Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
Builder’s Thermostat—Manual Changeover,
Non-Programmable, °F/°C,
1-Stage Heat, 1-Stage Cool
TSTATBBBAC01-B
TSTATXXSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXBBP01
TSTATXXSBP01
TSTATXXCNV10
See chart.
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat
Backplate for Builder’s Thermostat
Backplate for Standard Thermostat
Thermostat Conversion Kit (4 to 5 wire)—10 Pack
Evolution Controls
See notes on page 5.
.
—4—
SPECIFICATIONS Continued
UNIT SIZE-SERIES
042-F
048-F
060-H
Operating Weight (Lb)
247
295
331
ELECTRICAL
Unit Volts—Hertz—Phase
208/230—60—1
Operating Voltage Range*
187—253
20.5
109.0
1.4
Compressor— Rated Load Amps
Locked Rotor Amps
18.6
105.0
1.1
27.6
158.0
1.4
35.9
8
Condenser Fan Motor—Full Load Amps
Min Unit Ampacity for Wire Sizing
Min Wire Size (60°C Copper) AWG†
Min Wire Size (75°C Copper) AWG†
Max Wire Length (Ft) (60°C Copper)‡
Max Wire Length (Ft) (75°C Copper)‡
24.4
10
27.0
10
10
10
8
80
73
85
76
70
80
Max Branch Circuit Fuse or
Circuit Breaker Size (Amps)
40
40
60
COMPRESSOR & REFRIGERANT
Compressor— Type
Scroll
Temperature & Current Protection
Refrigerant— Type
Internal Line Break
Puron® (R-410A)
10.13
Amount (Lb)
8.75
11.50
CONDENSER COIL & FAN
Coil Face Area (Sq Ft)
Fins per In.—Rows—Circuits
Fan Motor—HP (PSC) & RPM
Volts—Hertz—Phase
18.2
18.2
20—2—5
18.2
25—1—3
1/5 & 825
20—2—5
1/4 & 1125
1/4 & 1125
208/230—60—1
3400
3400
Condenser Airflow (CFM)
OPTIONAL EQUIPMENT
Support Feet
2800
KSASF0101AAA
Coastal Filter
KAACF0801MED
KAATD0101TDR
Time Delay Relay
Cycle Protector
KSACY0101AAA
KAACH1201AAA
Crankcase Heater
Start Assist—Capacitor/Relay Type
Start Assist—PTC Type
TXV (Hard Shutoff)
KSAHS1501AAA
KSAHS1601AAA
KSATX0501PUR
KAACS0201PTC
KSATX0401PUR
KSAPX0101PIS
KH45LG141 (RCD)
KAAFT0101AAA
KAALS0201LLS
KAAWS0101AAA
KSALA0301410
KSALA0401AAA
KSATX0301PUR
Piston Body
Filter Drier (Suction Line)
Evaporator Freeze Thermostat**
Liquid-Line Solenoid Valve
Winter Start Control**
Low-Ambient Pressure Switch
MotorMaster® Low-Ambient Controller ††
Ball Bearing Fan Motor
HC38GE231 (RCD)
HC40GE232 (RCD)
Thermidistat™ Control—
Programmable Thermostat with Humidity Control
TSTATBBPRH01-B
TSTATBBPAC01-B
TSTATBBNAC01-C
TSTATBBSAC01
Thermostat—Auto Changeover, 7-Day Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
Thermostat—Auto Changeover, Non-Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
Thermostat—Manual Changeover, 5-2 Day Programmable,
°F/°C, 1-Stage Heat, 1-Stage Cool
Builder’s Thermostat—Manual Changeover,
Non-Programmable, °F/°C, 1-Stage Heat, 1-Stage Cool
TSTATBBBAC01-B
TSTATXXSEN01-B
TSTATXXNBP01
TSTATXXPBP01
TSTATXXBBP01
TSTATXXSBP01
TSTATXXCNV10
See chart.
Outdoor Air Temperature Sensor
Backplate for Non-Programmable Thermostat
Backplate for Programmable Thermostat
Backplate for Builder’s Thermostat
Backplate for Standard Thermostat
Thermostat Conversion Kit (4 to 5 wire)—10 Pack
Evolution Controls
* Permissible limits of the voltage range at which the unit will operate satisfactorily. Operation outside these limits may result in unit failure.
† If wire is applied at ambient greater than 30°C (86°F), consult Table 310-16 of the NEC (ANSI/NFPA 70).
The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60°C (140°F) conductors, per the NEC (ANSI/NFPA 70) Article
336-26. If other than uncoated (non-plated), 60 or 75°C (140 or 167°F) insulation, copper wire (solid wire for 10 AWG and smaller, stranded wire for larger
than 10 AWG) is used, consult applicable tables of the NEC (ANSI/NFPA 70).
‡ Length shown is as measured 1 way along wire path between unit and service panel for a voltage drop not to exceed 2%.
** See low-ambient controller Installation Instructions for application.
†† Fan motor with ball bearings required.
N/A — Not Applicable.
NOTE: Copper wire must be used from service disconnect to unit. All motors/compressors contain internal overload protection.
—5—
EVOLUTION™* CONTROLS
DESCRIPTION
ACCESSORY
Evolution Control Deluxe 7-Day Programmable (Wall-mounted system control.)
SYSTXBBUID01
Evolution Zone Control Deluxe Zoning 7-Day Programmable (Wall-mounted control for a
Z
SYSTXBBUIZ01
SYSTXBB4ZC01
SYSTXBBSMS01
SYSTXBBRRS01
SYSTXBBSAM01
multi-zone system.)
O
N
I
Evolution 4-Zone Damper Control Module (Wall-mounted control for a four-zone system.)
Evolution Smart Sensor (Optional wall control used to monitor temperature and/or fan control
in an individual zone.)
N
G
Evolution Remote Room Sensor (Monitors temperature in an individual zone.)
Evolution System Access Module (Hardware for wireless access and control via phone or
internet.)
Evolution Network Interface Module (Connects Heat Recovery or Energy Recovery Ventilators
or older two-speed outdoor models to system.)
SYSTXBBNIM01†
SYSTXXXBPU01
Back Plate for Evolution Control (Decorative wall plate.)
* When applied with Bryant’s Perfect Humidity™ series 355, 315 and FE Indoor Models.
† Must be installed in Dual-Fuel Evolution system applications.
ACCESSORY USAGE GUIDELINE
REQUIRED FOR
LOW-AMBIENT
APPLICATIONS
(Below 55°F)
REQUIRED FOR
REQUIRED FOR
LONG-LINE
APPLICATIONS*
(Over 50 Ft)
SEA COAST
APPLICATIONS
(Within 2 Miles)
ACCESSORY
Crankcase Heater
Yes
Yes
Yes†
No
Yes
No
No
No
No
No
No
No
Evaporator Freeze Thermostat
Winter Start Control
Accumulator
Compressor Start Assist
Capacitor and Relay
Yes
Yes
No
MotorMaster® Low-Ambient Controller
or
Yes
No
No
Low-Ambient Pressure Switch
Wind Baffle
Coastal Filter
Support Feet
See Low-Ambient Instructions
No
No
No
No
Yes
No
Recommended
Recommended
Liquid-Line Solenoid Valve
See Long-Line
Application
Guideline
or
No
No
No
Hard Shutoff TXV
Ball Bearing Fan Motor
Yes‡
No
* For tubing line sets greater than 50 ft horizontal and/or 20 ft vertical differential, refer to Residential Split-System Long-Line Application Guideline
and Service Manual.
† Only when low-pressure switch is used.
‡ Required for MotorMaster® Control only.
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
1. Ball-Bearing Fan Motor
A fan motor with ball bearings which permits speed reduction while maintaining bearing lubrication.
Usage Guideline:
Required on all units when low-ambient controller (full modulation feature) or MotorMaster®—Low-Ambient Controller is installed.
2. Coastal Filter
A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow.
3. Compressor Start Assist – Capacitor and Relay
Start capacitor and relay gives a "hard" boost to compressor motor at each start up.
Usage Guideline:
Required for reciprocating compressors in the following applications:
Long line
Low ambient
Hard shut off expansion valve on indoor coil
Liquid line solenoid on indoor coil
Required for scroll compressors in the following applications:
Long line
Low ambient
Suggested for all compressors in areas with a history of low voltage problems.
4. Compressor Start Assist — PTC Type
Solid state electrical device which gives a "soft" boost to the reciprocating compressor at each start-up.
Usage Guideline:
Suggested in installations with marginal power supply.
—6—
ACCESSORY DESCRIPTION AND USAGE (Listed Alphabetically)
5. Crankcase Heater
An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication
on restart and minimizes the chance of liquid slugging.
Usage Guideline:
Required in low ambient applications.
Required in long line applications.
Suggested in all commercial applications.
6. Evaporator Freeze Thermostat
An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions.
Usage Guideline:
Required when low ambient kit has been added.
7. Liquid-Line Solenoid Valve (LLS)
This device serves two purposes. It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor oper-
ation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle
refrigerant migration.
Note: When LLS is used with reciprocating compressors, Compressor Start Assist — Capacitor and Relay is required.
Usage Guideline:
Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration. A hard shut
off TXV can be used instead of an LLS in single flow air conditioner applications. See Long Line Application Guideline.
8. MotorMaster®—Low-Ambient Controller
A fan-speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing
temperature during operation in cooling mode only. For outdoor temperatures down to –20°F (–28.9°C), it maintains condensing temperature at 100°F
10°F (37.8°C –12°C).
Usage Guideline:
A MotorMaster®—Low Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor tem-
peratures below 55°F (12.8°C).
Suggested for all commercial applications.
9. Outdoor Air Temperature Sensor
Designed for use with Bryant Thermostats listed in this publication. This device enables the thermostat to display the outdoor temperature. This device also
is required to enable special thermostat features such as auxiliary heat lock out.
Usage Guideline:
Suggested for all Bryant thermostats listed in this publication.
10. Sound Hood
Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dBA.
Usage Guideline:
Suggested when unit is installed closer than 15 ft to quiet areas—bedrooms, etc.
Suggested when unit is installed between two houses less than 10 ft apart.
11. Support Feet
Four stick-on plastic feet that raise the unit 4 in. above the mounting pad. This allows sand, dirt, and other debris to be flushed from the unit base, minimizing
corrosion.
Usage Guideline:
Suggested in the following applications:
Coastal installations.
Windy areas or where debris is normally circulating.
Rooftop installations.
For improved sound ratings.
12. Thermostatic Expansion Valve (TXV)
A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the
evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Hard shut off types are available.
Note: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist — Capacitor and Relay is required.
Usage Guideline:
Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings.
Hard shut off TXV or LLS required in air conditioner long line applications
Required for use on all zoning systems.
13. Time-Delay Relay
An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off.
Note: Most indoor unit controls include this feature. For those that do not, use the guideline below.
Usage Guideline:
For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI Unitary Directory..
A-WTD. SOUND POWER (dBA)
TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment)
UNIT SIZE-
SERIES
STANDARD
RATING
125
61.0
57.5
58.5
55.5
62.0
66.0
250
60.5
60.0
60.5
62.5
67.5
68.0
500
63.5
64.0
65.0
66
1000
66.5
66.0
65.0
65.5
69.5
72.5
2000
63.0
62.0
62.0
63.5
67.5
70.5
4000
57.0
58.5
59.0
62.0
66.0
65.0
8000
49.5
53.5
52.5
55.5
60.5
59.5
024-G
030-F
72
70
72
72
76
78
036-F, G
042-F
048-F
70.0
71.5
060-H
NOTE: Tested in accordance with ARI standard 270.95. (Not listed with ARI.)
—7—
COMBINATION RATINGS
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
*CC5A/CD5AA030
CC5A/CD5AA024
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
23,000
22,800
22,800
23,000
22,800
23,000
22,800
22,800
23,000
22,800
23,000
22,800
23,000
22,800
23,000
22,800
23,000
23,000
23,400
23,000
23,400
23,600
23,600
23,000
23,400
23,000
23,400
22,000
23,400
23,600
23,600
23,600
23,600
23,400
NONE
NONE
—
—
13.00
12.50
12.50
13.00
12.50
13.00
12.50
12.50
13.00
12.50
13.00
12.50
13.00
12.50
13.00
12.50
13.00
—
13.00
12.50
12.50
13.00
12.50
13.00
12.50
12.50
13.00
12.50
13.00
12.50
13.00
—
11.25
11.15
11.15
11.25
11.25
11.35
11.15
11.30
11.35
11.30
11.35
11.30
11.35
11.30
11.35
11.30
11.35
11.40
11.50
11.40
11.55
12.85
13.00
11.20
11.35
11.20
11.35
11.00
12.65
12.85
13.00
12.85
13.00
11.70
NONE
—
NONE
—
NONE
—
CE3AA030
NONE
—
CF5AA024
NONE
—
CK3BA024
NONE
—
CK3BA030
NONE
—
CK5A/CK5BA024
CK5A/CK5BA030
CK5A/CK5BW024
CK5A/CK5BW030
CK5PA024
NONE
—
NONE
—
NONE
—
NONE
—
TXV
—
CK5PA030
TXV
—
—
CK5PW024
TXV
—
—
—
CK5PW030
TXV
—
F(A,B)4BN(F,C)024
F(A,B)4BN(F,C)030
FC4CNF024
TDR
13.00
13.00
13.00
13.00
14.50
14.50
12.50
13.00
12.50
13.00
—
13.00
13.00
—
TDR
—
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR
—
FC4CNF030
—
—
FE4ANF002
—
—
FE4ANF003
—
—
FF1DNA024
—
12.50
13.00
—
FF1DNA030
TDR
—
FF1DNE024
TDR&TXV
TDR&TXV
NONE
—
FF1DNE030
—
—
FG3AAA024
FK4DNF001
12.50
—
12.50
—
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
14.00
14.50
14.50
14.50
14.50
13.00
FK4DNF002
—
—
FK4DNF003
—
—
FV4BNF002
—
—
FV4BNF003
—
—
FX4BNF030
—
—
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
CC5A/CD5AA024
CC5A/CD5AA030
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.15
12.35
12.20
12.35
12.25
12.45
12.50
12.55
12.35
12.45
12.35
12.50
12.25
12.35
12.25
12.40
TDR
TDR
TDR
CE3AA030
TDR
CK3BA024
CK3BA030
TDR
024-G
TDR
CK5A/CK5BA024
CK5A/CK5BA030
CK5A/CK5BW024
CK5A/CK5BW030
CK5PA024
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA030
—
CK5PW024
—
—
CK5PW030
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AA024
CC5A/CD5AA030
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.25
12.50
12.35
12.50
12.35
12.55
12.60
12.65
12.45
12.55
12.45
12.60
12.35
12.50
12.40
12.55
TDR
TDR
TDR
CE3AA030
TDR
CK3BA024
CK3BA030
TDR
TDR
CK5A/CK5BA024
CK5A/CK5BA030
CK5A/CK5BW024
CK5A/CK5BW030
CK5PA024
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA030
—
CK5PW024
—
—
CK5PW030
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.25
12.40
12.20
12.50
12.55
12.60
12.35
12.55
12.30
12.45
TDR
CE3AA030
TDR
CK3BA024
CK3BA030
TDR
TDR
CK5A/CK5BW024
CK5A/CK5BW030
CK5PW024
TDR
TDR
TDR&TXV
TDR&TXV
CK5PW030
—
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CE3AA024
CE3AA030
22,400
22,800
TDR
TDR
14.00
14.00
—
—
14.00
14.00
12.25
12.50
See notes on page 22.
—8—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CE3AA024
CE3AA030
22,400
22,800
TDR
TDR
14.00
14.00
—
—
14.00
14.00
12.30
12.55
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CE3AA024
CE3AA030
22,400
22,800
TDR
TDR
14.00
14.00
—
—
14.00
14.00
12.20
12.45
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AA024
CC5A/CD5AA030
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.15
12.40
12.25
12.40
12.25
12.45
12.55
12.60
12.35
12.45
12.40
12.55
12.30
12.40
12.30
12.45
TDR
TDR
TDR
CE3AA030
TDR
CK3BA024
CK3BA030
TDR
TDR
CK5A/CK5BA024
CK5A/CK5BA030
CK5A/CK5BW024
CK5A/CK5BW030
CK5PA024
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA030
—
CK5PW024
—
—
CK5PW030
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.20
12.35
12.20
12.45
12.50
12.55
12.35
12.50
12.30
12.40
TDR
CE3AA030
TDR
CK3BA024
CK3BA030
TDR
024-G
TDR
CK5A/CK5BW024
CK5A/CK5BW030
CK5PW024
TDR
TDR
TDR&TXV
TDR&TXV
CK5PW030
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.25
12.40
12.25
12.45
12.50
12.55
12.40
12.50
12.30
12.45
TDR
CE3AA030
TDR
CK3BA024
CK3BA030
TDR
TDR
CK5A/CK5BW024
CK5A/CK5BW030
CK5PW024
TDR
TDR
TDR&TXV
TDR&TXV
CK5PW030
—
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AW024
CC5A/CD5AW030
CE3AA024
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
22,400
22,800
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.25
12.40
12.25
12.50
12.55
12.60
12.40
12.50
12.30
12.45
TDR
CE3AA030
TDR
CK3BA024
CK3BA030
TDR
TDR
CK5A/CK5BW024
CK5A/CK5BW030
CK5PW024
TDR
TDR
TDR&TXV
TDR&TXV
CK5PW030
—
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CE3AA024
CE3AA030
22,400
22,800
TDR
TDR
14.00
14.00
—
—
14.00
14.00
12.20
12.45
*CC5A/CD5AA036
CC5A/CD5AA030
CC5A/CD5AW030
CC5A/CD5AW036
CE3AA030
29,000
28,000
28,000
29,000
28,000
28,400
28,400
28,000
29,000
28,000
29,000
29,000
28,000
29,000
28,000
29,000
29,000
28,000
29,000
28,600
29,000
29,000
29,600
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
TXV
—
—
13.00
12.50
12.50
13.00
12.50
12.50
12.50
12.50
13.00
12.50
13.00
13.00
12.50
13.00
12.50
13.00
13.00
12.50
13.00
—
13.00
12.50
12.50
13.00
12.50
12.50
12.50
12.50
13.00
12.50
13.00
13.00
12.50
13.00
—
11.20
10.85
10.85
11.20
11.00
11.10
11.15
10.95
11.25
10.95
11.25
11.25
10.95
11.25
10.95
11.25
11.25
10.95
11.25
11.10
10.95
12.05
12.55
—
—
—
CE3AA036
—
CF5AA036
—
CK3BA030
—
CK3BA036
—
CK5A/CK5BA030
CK5A/CK5BA036
CK5A/CK5BT036
CK5A/CK5BW030
CK5A/CK5BW036
CK5PA030
—
—
030-F
—
—
—
—
CK5PA036
TXV
—
—
CK5PT036
TXV
—
—
CK5PW030
TXV
—
—
CK5PW036
TXV
—
—
F(A,B)4(A,B)N(F,C)030
F(A,B)4(A,B)N(F,C)036
FE4ANF002
TDR
12.50
12.50
13.50
14.00
12.50
12.50
—
TDR
—
TDR&TXV
TDR&TXV
—
—
FE4ANF003
—
See notes on page 22.
—9—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
FF1DNA030
FG3AAA036
28,600
28,400
29,000
29,000
29,600
29,000
29,600
28,600
29,000
TDR
12.50
—
—
12.50
—
12.50
12.50
—
11.05
11.00
11.95
12.05
12.40
12.05
12.55
11.00
10.95
NONE
FK4(C,D)NF001
FK4(C,D)NF002
FK4(C,D)NF003
FV4(A,B)NF002
FV4(A,B)NF003
FX4(A,B)NF030
FX4(A,B)NF036
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
13.00
13.50
14.00
13.50
14.00
12.50
12.50
—
—
—
—
—
—
—
—
—
—
—
—
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
CC5A/CD5AA030
CC5A/CD5AA036
CC5A/CD5AW030
CE3AA030
28,000
29,000
28,000
28,400
28,600
28,000
29,000
28,000
29,000
29,000
28,000
28,600
29,000
29,000
28,600
TDR
TDR
13.50
14.00
13.50
13.50
13.50
13.50
14.00
13.50
14.00
14.00
13.50
13.50
14.00
14.00
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
14.00
13.50
13.50
13.50
13.50
14.00
13.50
14.00
14.00
13.50
—
11.65
12.00
11.65
11.75
11.85
11.70
12.05
11.70
12.05
12.05
11.70
11.70
12.05
12.05
11.70
TDR
TDR
CE3AA036
TDR
CK3BA030
CK3BA036
TDR
TDR
CK5A/CK5BA030
CK5A/CK5BA036
CK5A/CK5BT036
CK5A/CK5BW030
CK5PA030
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA036
—
CK5PT036
—
—
CK5PW030
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AA030
CC5A/CD5AA036
CC5A/CD5AW030
CC5A/CD5AW036
CE3AA030
28,000
29,000
28,000
29,000
28,600
28,800
28,000
29,000
28,000
29,000
28,600
29,000
28,600
29,000
29,000
28,600
29,000
TDR
TDR
13.50
14.00
13.50
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
13.50
14.00
14.00
13.50
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
14.00
13.50
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
—
11.80
12.15
11.80
12.15
11.90
12.05
11.85
12.20
11.85
12.20
11.85
12.20
11.80
12.20
12.20
11.80
12.20
TDR
TDR
TDR
CE3AA036
TDR
CK3BA030
CK3BA036
TDR
TDR
CK5A/CK5BA030
CK5A/CK5BA036
CK5A/CK5BW030
CK5A/CK5BW036
CK5PA030
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA036
—
CK5PT036
—
CK5PW030
—
030-F
CK5PW036
—
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AW030
CC5A/CD5AW036
CE3AA030
29,000
28,000
29,000
28,600
29,000
28,600
29,000
29,000
29,000
28,600
29,000
29,000
29,000
28,600
29,000
TDR
TDR
14.00
13.50
14.00
13.50
14.00
13.50
14.00
14.00
14.00
13.50
14.00
14.00
14.00
13.50
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14.00
13.50
14.00
13.50
14.00
13.50
14.00
14.00
14.00
13.50
14.00
—
12.40
12.05
12.45
12.15
12.30
12.20
12.45
12.45
12.45
12.15
12.50
12.45
12.45
12.15
12.50
TDR
TDR
CE3AA036
TDR
CK3BA030
CK3BA036
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BT036
CK5A/CK5BW030
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT036
—
CK5PW030
—
—
CK5PW036
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AW036
CE3AA030
29,000
28,600
29,000
29,000
29,000
TDR
TDR
14.00
13.50
14.00
14.00
14.00
—
—
—
—
—
14.00
13.50
14.00
14.00
—
12.55
12.25
12.40
12.60
12.60
CE3AA036
TDR
CK5A/CK5BW036
CK5PW036
TDR
TDR&TXV
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AW036
CE3AA030
29,000
28,600
29,000
29,000
29,000
TDR
TDR
14.00
13.50
14.00
14.00
14.00
—
—
—
—
—
14.00
13.50
14.00
14.00
—
12.60
12.30
12.45
12.65
12.65
CE3AA036
TDR
CK5A/CK5BW036
CK5PW036
TDR
TDR&TXV
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AW030
CC5A/CD5AW036
CE3AA030
28,400
29,600
29,000
29,200
28,400
29,600
28,400
29,600
28,400
29,600
TDR
TDR
13.20
13.50
13.50
13.50
13.00
13.50
13.00
13.50
13.00
13.50
—
—
—
—
—
—
—
—
—
—
13.20
13.50
13.50
13.50
13.00
13.50
13.00
13.50
—
11.55
11.90
11.70
11.75
11.45
11.95
11.45
11.95
11.45
11.95
TDR
CE3AA036
TDR
CK3BA030
CK3BA036
TDR
TDR
CK5A/CK5BW030
CK5A/CK5BW036
CK5PW030
TDR
TDR
TDR&TXV
TDR&TXV
CK5PW036
—
See notes on page 22.
—10—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AW030
CE3AA030
29,600
28,400
29,000
29,200
28,400
29,600
29,600
29,600
28,400
29,600
29,600
28,400
TDR
TDR
13.50
13.20
13.20
13.50
13.20
13.50
13.50
13.50
13.20
13.50
13.50
13.20
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.20
13.20
13.50
13.20
13.50
13.50
13.50
13.20
—
11.90
11.50
11.65
11.75
11.45
11.95
11.95
11.95
11.45
11.95
11.95
11.45
TDR
CE3AA036
TDR
CK3BA030
CK3BA036
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BT036
CK5A/CK5BW030
CK5PA036
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT036
CK5PW030
—
030-F
—
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AW030
CC5A/CD5AW036
CE3AA030
28,600
29,600
29,000
29,200
28,600
29,600
28,600
29,600
28,600
29,600
TDR
TDR
13.50
14.00
13.50
13.50
13.20
14.00
13.20
14.00
13.20
14.00
—
—
—
—
—
—
—
—
—
—
13.50
14.00
13.50
13.50
13.20
14.00
13.20
14.00
—
11.65
12.10
11.80
11.90
11.55
12.10
11.55
12.10
11.55
12.10
TDR
CE3AA036
TDR
CK3BA030
CK3BA036
TDR
TDR
CK5A/CK5BW030
CK5A/CK5BW036
CK5PW030
TDR
TDR
TDR&TXV
TDR&TXV
CK5PW036
—
*CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
36,000
35,000
35,000
35,000
36,000
35,000
35,000
36,000
34,000
35,000
NONE
NONE
—
—
13.00
13.00
13.00
12.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
13.00
13.00
13.00
12.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
11.20
11.20
11.20
11.05
11.30
11.15
11.20
11.20
11.20
11.20
11.20
11.20
11.20
11.20
11.20
11.20
11.20
11.20
11.25
11.15
11.75
12.05
12.20
10.95
11.75
12.05
12.20
11.75
12.05
12.20
10.95
11.20
NONE
—
NONE
—
CE3AA042
NONE
—
CF5AA036
NONE
—
CK3BA036
NONE
—
CK3BA042
NONE
—
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
NONE
—
NONE
—
NONE
—
NONE
—
NONE
—
TXV
—
CK5PA042
TXV
—
—
CK5PT036
TXV
—
—
CK5PT042
TXV
—
—
CK5PW036
TXV
—
—
F(A,B)4(A,B)N(F,B,C)042
F(A,B)4(A,B)N(F,C)036
FE4ANF002
TDR
13.00
12.50
13.00
13.50
14.00
—
13.00
12.50
—
TDR
—
TDR&TXV
TDR&TXV
TDR&TXV
NONE
—
FE4ANF003
—
—
—
FE4ANF005
—
FG3AAA036
12.20
—
12.20
—
FK4(C,D)NF002
FK4(C,D)NF003
FK4(C,D)NF005
FV4(A,B)NF002
FV4(A,B)NF003
FV4(A,BNF005
FX4(A,B)NF036
FX4(A,B)NF042
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
13.00
13.50
14.00
13.00
13.50
14.00
12.25
13.00
—
—
—
—
—
—
—
—
—
—
036-F
—
—
—
—
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.50
13.20
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
13.50
13.20
13.50
13.50
13.50
13.50
13.50
—
11.80
11.70
11.95
11.90
11.90
12.00
11.90
11.90
12.00
11.90
CE3AA042
TDR
CK3BA036
TDR
CK5A/CK5BA036
CK5A/CK5BE042
CK5A/CK5BT036
CK5PA036
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PE042
CK5PT036
—
—
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.50
14.00
13.50
13.20
14.00
13.50
14.00
13.50
14.00
14.00
13.50
14.00
13.50
13.50
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
14.00
13.50
13.20
14.00
13.50
14.00
13.50
14.00
14.00
13.50
14.00
13.50
—
12.00
12.15
12.00
11.90
12.15
12.10
12.15
12.10
12.15
12.20
12.10
12.15
12.10
12.05
12.15
TDR
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
CK5PA042
—
See notes on page 22.
—11—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
CK5PE042
CK5PT036
CK5PT042
CK5PW036
35,000
35,000
35,000
35,000
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
14.00
13.50
14.00
13.50
—
—
—
—
—
—
—
—
12.20
12.05
12.15
12.05
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
14.00
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.00
12.05
12.00
11.95
11.85
12.10
12.00
12.10
12.00
12.10
12.15
12.00
12.10
12.10
12.00
12.05
12.15
12.00
12.05
12.05
TDR
TDR
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA042
—
CK5PE042
—
CK5PT036
—
CK5PT042
—
CK5PW036
—
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
—
12.20
12.05
12.15
11.95
12.20
12.20
12.20
12.20
12.10
12.20
12.20
12.10
TDR
TDR
CE3AA042
TDR
CK3BA042
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
—
12.30
12.10
12.25
12.00
12.30
12.30
12.30
12.30
12.15
12.25
12.25
12.15
036-F
TDR
TDR
CE3AA042
TDR
CK3BA042
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.20
13.00
13.20
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
—
—
—
—
—
—
—
—
—
—
13.20
13.00
13.20
13.00
13.00
13.00
13.00
13.00
—
11.60
11.35
11.60
11.45
11.45
11.45
11.45
11.45
11.45
11.45
11.45
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.20
13.00
13.20
13.00
13.20
13.00
13.00
13.00
13.00
13.00
13.00
—
—
—
—
—
—
—
—
—
—
—
13.20
13.00
13.20
13.00
13.20
13.00
13.00
13.00
—
11.45
11.35
11.60
11.50
11.60
11.50
11.50
11.50
11.50
11.50
11.50
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BT036
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT036
CK5PW036
—
—
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
35,000
35,000
35,000
35,000
35,000
TDR
TDR
TDR
TDR
TDR
13.50
13.20
13.00
13.50
13.20
—
—
—
—
—
13.50
13.20
13.00
13.50
13.20
11.85
11.65
11.55
11.85
11.60
CE3AA042
CK3BA036
See notes on page 22.
—12—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
CK3BA042
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.50
13.50
13.50
13.20
13.50
13.50
13.20
—
—
—
—
—
—
—
13.50
13.50
13.50
13.20
—
11.75
11.75
11.75
11.60
11.75
11.75
11.60
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
—
CK5PW036
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.50
13.50
13.00
13.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.00
13.50
13.00
13.00
13.00
13.00
13.00
—
11.90
11.75
11.60
11.90
11.45
11.60
11.60
11.60
11.45
11.60
11.60
11.45
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.50
13.50
13.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.00
13.50
13.50
13.50
13.50
13.50
13.50
—
11.90
11.75
11.60
11.90
11.80
12.00
12.00
12.00
11.80
12.00
12.00
11.80
036-F
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
TDR
TDR
13.50
13.50
13.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.00
13.50
13.50
13.50
13.50
13.50
13.50
—
11.90
11.75
11.60
11.90
11.85
12.00
12.00
12.00
11.85
12.00
12.00
11.85
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
CC5A/CD5AA036*
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
35,000
35,000
35,000
34,600
34,600
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
35,000
34,600
35,000
34,600
36,000
35,000
35,000
36,000
34,000
35,000
36,000
34,600
35,000
35,000
36,000
36,000
35,000
NONE
NONE
—
—
13.00
13.00
13.00
12.50
12.50
13.00
12.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
13.00
13.00
13.00
12.50
12.50
13.00
12.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
11.25
11.25
11.25
11.10
11.15
11.30
11.20
11.30
11.30
11.30
11.30
11.35
11.30
11.30
11.30
11.30
11.30
11.35
11.30
11.30
11.30
11.20
10.90
11.20
10.90
13.05
12.00
12.40
12.85
10.95
11.20
13.05
11.75
12.00
12.40
12.85
13.05
12.00
NONE
—
NONE
—
NONE
—
CE3AA042
NONE
—
CF5AA036
NONE
—
CK3BA036
NONE
—
CK3BA042
NONE
—
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
NONE
—
NONE
—
NONE
—
NONE
—
NONE
—
NONE
—
TXV
—
CK5PA042
TXV
—
—
CK5PE042
TXV
—
—
CK5PT036
TXV
—
—
036-G
CK5PT042
TXV
—
—
CK5PW036
TXV
—
—
F(A,B)4BN(F,B,C)042
F(A,B)4BN(F,C)036
FC4CN(F,B)042
FC4CNF036
TDR
12.50
12.50
12.50
12.50
14.50
13.50
14.00
14.50
—
12.50
12.50
—
TDR
—
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
NONE
—
—
—
FE4ANB006
—
—
FE4ANF002
—
—
FE4ANF003
—
—
FE4ANF005
—
—
FG3AAA036
12.50
12.50
—
12.50
12.50
—
FG3AAA048
NONE
—
FK4DNB006
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
14.50
13.00
13.50
14.00
14.50
14.50
13.50
FK4DNF001
—
—
FK4DNF002
—
—
FK4DNF003
—
—
FK4DNF005
—
—
FV4BNB006
—
—
FV4BNF002
—
—
See notes on page 22.
—13—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
FV4BNF003
FV4BNF005
FX4BNF036
FX4BNF042
35,000
36,000
35,000
35,600
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
14.00
14.50
12.50
13.00
—
—
—
—
—
—
—
—
12.40
12.85
11.20
11.40
COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CE3AA036
34,400
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
13.50
13.50
13.50
13.50
14.00
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
14.00
13.50
—
11.85
11.70
11.95
11.90
11.90
12.00
11.90
11.90
12.00
11.90
CE3AA042
TDR
CK3BA036
TDR
CK5A/CK5BA036
CK5A/CK5BE042
CK5A/CK5BT036
CK5PA036
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PE042
CK5PT036
—
—
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
34,400
34,400
34,400
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.05
12.10
12.10
11.90
12.15
12.10
12.15
12.10
12.15
12.20
12.10
12.15
12.15
12.05
12.15
12.20
12.05
12.15
12.10
TDR
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA042
—
CK5PE042
—
CK5PT036
—
CK5PT042
—
CK5PW036
—
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
34,400
34,200
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.05
12.10
12.10
12.00
11.90
12.15
12.10
12.15
12.10
12.15
12.20
12.10
12.15
12.15
12.05
12.15
12.20
12.05
12.15
12.10
TDR
TDR
036-G
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA042
—
CK5PE042
—
CK5PT036
—
CK5PT042
—
CK5PW036
—
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
34,200
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
13.50
14.00
14.00
14.00
14.00
14.00
—
12.20
12.15
12.10
11.95
12.25
12.20
12.20
12.20
12.20
12.20
12.20
12.20
TDR
TDR
CE3AA042
TDR
CK3BA042
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
34,200
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
14.00
—
12.30
12.25
12.20
12.05
12.35
12.30
12.30
12.30
12.30
12.30
12.30
12.30
TDR
TDR
CE3AA042
TDR
CK3BA042
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
See notes on page 22.
—14—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
33,800
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
11.85
11.85
11.75
11.65
11.90
11.90
11.90
11.90
11.90
11.85
11.85
11.85
TDR
TDR
CE3AA042
TDR
CK3BA042
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CE3AA036
34,400
34,400
34,400
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
11.95
12.05
12.00
11.80
12.10
12.00
12.05
12.00
12.05
12.15
12.00
12.05
12.05
12.00
12.05
12.10
12.00
12.05
12.05
TDR
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA042
—
CK5PE042
—
CK5PT036
—
CK5PT042
—
CK5PW036
—
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
34,400
33,800
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
11.75
11.85
11.80
11.75
11.60
11.90
11.80
11.85
11.80
11.85
11.90
11.80
11.85
11.85
11.75
11.85
11.90
11.75
11.85
11.85
TDR
TDR
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
036-G
TDR
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA042
—
CK5PE042
—
CK5PT036
—
CK5PT042
—
CK5PW036
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
34,400
33,800
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
11.90
12.00
11.95
11.85
11.80
12.05
12.00
12.00
11.95
12.00
12.10
11.95
12.00
12.00
11.95
12.00
12.05
11.95
12.00
12.00
TDR
TDR
TDR
CE3AA042
TDR
CK3BA036
CK3BA042
TDR
TDR
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA042
—
CK5PE042
—
CK5PT036
—
CK5PT042
—
CK5PW036
—
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA036
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
34,400
33,800
34,000
34,600
TDR
TDR
TDR
TDR
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
11.95
12.05
12.00
11.90
11.85
12.10
CE3AA042
See notes on page 22.
—15—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
CK3BA036
CK3BA042
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
12.00
12.05
12.00
12.05
12.15
12.00
12.05
12.05
12.00
12.05
12.10
12.00
12.05
12.05
CK5A/CK5BA036
CK5A/CK5BA042
CK5A/CK5BE042
CK5A/CK5BT036
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA036
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA042
—
CK5PE042
—
CK5PT036
—
CK5PT042
—
CK5PW036
—
036-G
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW036
CC5A/CD5AW042
CE3AA036
34,400
34,400
33,800
34,000
34,600
34,600
34,600
34,600
34,600
34,600
34,600
34,600
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
12.05
12.05
12.00
11.85
12.10
12.10
12.10
12.10
12.10
12.10
12.10
12.10
TDR
TDR
CE3AA042
TDR
CK3BA042
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW036
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW036
—
—
*CD5AA048
CC5A/CD5AA042
CC5A/CD5AC048
CC5A/CD5AW048
CE3AA042
40,500
40,500
40,000
40,500
41,000
41,000
40,500
40,500
40,500
40,500
40,500
39,500
40,500
40,500
40,500
40,500
40,500
39,500
40,500
40,500
40,500
40,500
41,000
41,500
39,500
41,000
40,000
41,500
39,500
41,000
41,500
39,500
41,000
40,000
40,500
NONE
NONE
—
—
13.00
13.00
12.50
13.00
13.00
13.00
12.50
13.00
13.00
13.00
13.00
12.50
13.00
13.00
13.00
13.00
13.00
12.50
13.00
13.00
13.00
—
13.00
13.00
12.50
13.00
13.00
13.00
12.50
13.00
13.00
13.00
13.00
12.50
13.00
13.00
13.00
—
11.25
11.15
11.00
11.20
11.30
11.35
11.20
11.20
11.30
11.20
11.30
11.30
11.20
11.30
11.30
11.20
11.30
11.30
11.20
11.30
11.30
11.25
11.45
12.90
11.95
12.50
11.25
12.90
12.00
12.55
12.90
11.95
12.50
11.10
11.20
NONE
—
NONE
—
NONE
—
CE3AA048
NONE
—
CF5AA048
NONE
—
CK3BA042
NONE
—
CK3BA048
NONE
—
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BE042
CK5A/CK5BT042
CK5A/CK5BT048
CK5A/CK5BW048
CK5PA042
NONE
—
NONE
—
NONE
—
NONE
—
NONE
—
NONE
—
TXV
—
CK5PA048
TXV
—
—
CK5PE042
TXV
—
—
CK5PT042
TXV
—
—
CK5PT048
TXV
—
—
CK5PW048
TXV
—
—
F(A,B)4(A,B)N(F,B,C)042
F(A,B)4(A,B)N(F,B,C)048
FE4ANB006
TDR
12.50
13.00
14.00
13.00
13.50
—
12.50
13.00
—
TDR
—
TDR&TXV
TDR&TXV
TDR&TXV
NONE
—
FE4ANF003
—
—
—
FE4ANF005
—
FG3AAA048
12.50
—
12.50
—
FK4(C,D)NB006
FK4(C,D)NF003
FK4(C,D)NF005
FV4(A,B)NB006
FV4(A,B)NF003
FV4(A,B)NF005
FX4(A,B)NF042
FX4(A,B)NF048
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
14.00
13.00
13.50
14.00
13.00
13.50
12.50
12.50
—
—
042-F
—
—
—
—
—
—
—
—
—
—
—
—
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AC048
CD5AA048
40,000
40,000
40,500
40,500
41,000
40,500
40,500
40,000
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
TDR
TDR
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
11.85
11.85
12.00
11.90
11.95
11.90
12.00
11.90
12.00
11.95
11.90
12.00
11.90
12.00
11.95
11.90
12.00
TDR
CE3AA042
TDR
CE3AA048
TDR
CK3BA042
TDR
CK3BA048
TDR
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BE042
CK5A/CK5BT042
CK5A/CK5BT048
CK5PA042
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA048
—
CK5PE042
—
CK5PT042
—
CK5PT048
—
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AC048
CC5A/CD5AW042
40,000
40,000
39,500
TDR
TDR
TDR
13.50
13.50
13.50
—
—
—
13.50
13.50
13.50
11.80
11.70
11.75
See notes on page 22.
—16—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
CC5A/CD5AW048
CD5AA048
40,500
40,500
40,500
41,000
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
TDR
TDR
14.00
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
13.50
14.00
14.00
13.50
14.00
13.50
13.50
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
14.00
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
13.50
14.00
14.00
—
11.95
11.90
11.85
11.90
11.80
12.00
11.80
11.95
11.85
11.80
11.95
12.05
11.75
11.95
11.85
11.75
11.95
12.05
CE3AA042
TDR
CE3AA048
TDR
CK3BA042
TDR
CK3BA048
TDR
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BE042
CK5A/CK5BT042
CK5A/CK5BT048
CK5A/CK5BW048
CK5PA042
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA048
—
CK5PE042
—
CK5PT042
—
CK5PT048
—
CK5PW048
—
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AC048
CC5A/CD5AW042
CC5A/CD5AW048
CD5AA048
40,500
40,000
40,000
40,500
40,500
40,500
41,000
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
TDR
TDR
13.50
13.50
13.50
14.00
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
14.00
13.50
14.00
13.50
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
14.00
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
14.00
—
11.95
12.00
11.85
12.15
12.15
12.05
12.10
12.00
12.15
12.00
12.15
12.00
12.15
12.15
12.00
12.15
12.00
12.15
12.15
TDR
TDR
TDR
CE3AA042
TDR
CE3AA048
TDR
CK3BA042
TDR
CK3BA048
TDR
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BT042
CK5A/CK5BT048
CK5A/CK5BW048
CK5PA042
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA048
—
CK5PT042
—
CK5PT048
—
CK5PW048
—
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AC048
CC5A/CD5AW042
CC5A/CD5AW048
CD5AA048
40,500
40,000
40,000
40,500
40,500
40,500
41,000
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
TDR
TDR
13.50
13.50
13.50
14.00
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
14.00
13.50
14.00
13.50
14.00
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
14.00
14.00
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
14.00
—
12.00
12.05
11.90
12.20
12.20
12.05
12.10
12.05
12.20
12.05
12.20
12.05
12.20
12.20
12.05
12.20
12.05
12.20
12.20
042-F
TDR
TDR
TDR
CE3AA042
TDR
CE3AA048
TDR
CK3BA042
TDR
CK3BA048
TDR
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BT042
CK5A/CK5BT048
CK5A/CK5BW048
CK5PA042
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA048
—
CK5PT042
—
CK5PT048
—
CK5PW048
—
COILS + 355MAV042040 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW048
CE3AA042
40,500
40,500
40,000
40,000
TDR
TDR
TDR
TDR
12.80
13.00
13.00
13.00
—
—
—
—
12.80
13.00
13.00
13.00
11.05
11.30
11.15
11.20
CE3AA048
COILS + 355MAV042060 VARIABLE-SPEED FURNACE
CC5A/CD5AC048
CD5AA048
40,000
40,000
40,500
40,500
TDR
TDR
TDR
TDR
12.50
13.00
13.00
13.00
—
—
—
—
12.50
13.00
13.00
13.00
11.15
11.35
11.20
11.25
CE3AA042
CE3AA048
COILS + 355MAV042080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AC048
CD5AA048
40,500
40,000
40,500
41,000
41,000
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
TDR
TDR
13.00
13.00
13.50
13.00
13.20
13.00
13.20
13.00
13.20
13.00
13.20
13.00
13.20
—
—
—
—
—
—
—
—
—
—
—
—
—
13.00
13.00
13.50
13.00
13.20
13.00
13.20
13.00
13.20
13.00
13.20
—
11.40
11.45
11.60
11.50
11.55
11.30
11.55
11.30
11.55
11.30
11.55
11.30
11.55
TDR
CE3AA042
TDR
CE3AA048
TDR
CK3BA042
TDR
CK3BA048
TDR
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BT042
CK5A/CK5BT048
CK5PA042
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
CK5PA048
—
See notes on page 22.
—17—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
CK5PT042
CK5PT048
40,500
40,500
TDR&TXV
TDR&TXV
13.00
13.20
—
—
—
—
11.30
11.55
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AC048
CD5AA048
40,500
40,000
40,500
41,000
41,000
TDR
TDR
TDR
TDR
TDR
13.20
13.20
13.50
13.20
13.50
—
—
—
—
—
13.20
13.20
13.50
13.20
13.50
11.50
11.55
11.75
11.60
11.65
CE3AA042
CE3AA048
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AC048
CD5AA048
40,500
40,000
40,500
41,000
41,000
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
TDR
TDR
13.20
13.20
13.50
13.20
13.50
13.00
13.50
13.00
13.50
13.00
13.50
13.00
13.50
13.00
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.20
13.20
13.50
13.20
13.50
13.00
13.50
13.00
13.50
13.00
13.50
—
11.50
11.55
11.75
11.60
11.65
11.55
11.80
11.55
11.80
11.55
11.80
11.55
11.80
11.55
11.80
TDR
CE3AA042
TDR
CE3AA048
TDR
CK3BA042
TDR
CK3BA048
TDR
CK5A/CK5BA042
CK5A/CK5BA048
CK5A/CK5BT042
CK5A/CK5BT048
CK5PA042
TDR
TDR
042-F
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA048
—
CK5PT042
—
—
CK5PT048
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA042
CC5A/CD5AW048
CE3AA042
40,500
40,500
41,000
41,000
40,500
40,500
40,500
40,500
40,500
40,500
40,500
40,500
TDR
TDR
13.20
13.50
13.20
13.50
13.00
13.50
13.00
13.00
13.50
13.00
13.00
13.50
—
—
—
—
—
—
—
—
—
—
—
—
13.20
13.50
13.20
13.50
13.00
13.50
13.00
13.00
13.50
—
11.50
11.75
11.60
11.65
11.65
11.85
11.65
11.65
11.85
11.65
11.65
11.85
TDR
CE3AA048
TDR
CK3BA042
CK3BA048
TDR
TDR
CK5A/CK5BA042
CK5A/CK5BT042
CK5A/CK5BW048
CK5PA042
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT042
CK5PW048
—
—
*CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CC5A/CD5AW060
CD5AA048
46,500
45,000
46,000
47,000
46,000
47,500
46,500
47,000
46,000
46,000
46,500
46,000
46,500
46,000
46,500
46,000
47,000
46,000
46,500
46,000
46,500
46,000
47,000
46,000
47,000
47,500
47,500
47,000
46,000
46,500
47,500
47,000
47,500
47,000
47,000
46,000
NONE
NONE
NONE
NONE
NONE
TXV
—
—
13.00
12.50
13.00
13.00
13.00
13.50
13.00
13.00
12.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
13.00
12.50
13.00
13.00
13.00
—
11.50
11.35
11.50
11.80
11.50
11.90
11.65
11.85
11.55
11.55
11.65
11.55
11.65
11.55
11.65
11.55
11.90
11.55
11.65
11.55
11.65
11.55
11.90
11.50
11.55
12.00
13.15
12.40
11.50
11.65
13.15
12.40
13.15
12.40
11.50
11.50
—
—
—
CD5PX060
—
CE3AA048
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
NONE
TXV
—
13.00
13.00
12.50
13.00
13.00
13.00
13.00
13.00
13.00
13.00
13.00
—
CE3AA060
—
CF5AA048
—
CK3BA048
—
CK3BA060
—
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
CK5PA048
—
—
—
—
—
—
—
CK5PA060
TXV
—
—
CK5PT048
TXV
—
—
CK5PT060
TXV
—
—
CK5PW048
TXV
—
—
CK5PX060
TXV
—
—
048-F
F(A,B)4(A,B)N(F,B,C)048
F(A,B)4(A,B)N(F,B,C)060
FB4(A,B)NB070
FE4ANB006
TDR
12.20
12.50
13.00
14.00
13.80
—
12.20
12.50
13.00
—
TDR
—
TDR
—
TDR&TXV
TDR&TXV
NONE
NONE
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
—
FE4ANF005
—
—
FG3AAA048
12.20
12.50
—
12.20
12.50
—
FG3AAA060
—
FK4(C,D)NB006
FK4(C,D)NF005
FV4(A,B)NB006
FV4(A,B)NF005
FX4(A,B)NB060
FX4(A,B)NF048
14.00
13.80
14.00
13.80
12.50
12.20
—
—
—
—
—
—
—
—
—
—
COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE
CC5A/CD5AC048
CD5AA048
45,000
46,000
46,500
47,000
46,000
46,000
46,000
46,000
46,000
TDR
TDR
13.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
13.50
—
—
—
—
—
—
—
—
—
13.00
13.50
13.50
13.50
13.50
13.50
13.50
—
11.80
11.95
11.95
12.25
11.95
11.95
11.95
11.90
11.90
CE3AA048
TDR
CE3AA060
CK3BA048
TDR
TDR
CK5A/CK5BA048
CK5A/CK5BT048
CK5PA048
TDR
TDR
TDR&TXV
TDR&TXV
CK5PT048
—
See notes on page 22.
—18—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CD5AA048
46,000
45,000
45,500
45,500
46,000
47,000
46,000
46,500
46,000
46,500
46,000
46,500
46,000
47,500
46,000
46,500
46,000
46,500
46,000
47,500
TDR
TDR
13.00
13.00
13.50
13.50
13.00
14.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
14.00
13.50
13.50
13.50
13.50
13.50
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.00
13.00
13.50
13.50
13.00
14.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
14.00
—
12.00
11.70
11.95
11.95
11.95
12.35
12.00
12.35
11.95
12.35
11.95
12.40
12.05
12.50
11.90
12.35
11.90
12.35
12.00
12.50
TDR
TDR
CE3AA048
TDR
CE3AA060
TDR
CK3BA048
TDR
CK3BA060
TDR
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
CK5PA048
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA060
—
CK5PT048
—
CK5PT060
—
CK5PW048
—
CK5PX060
—
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CC5A/CD5AW060
CD5AA048
46,000
45,000
46,000
47,000
46,000
47,500
46,500
47,000
46,000
46,500
46,000
46,500
46,000
46,500
46,000
47,500
46,000
46,500
46,000
46,500
46,000
47,500
TDR
TDR
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
14.00
13.50
13.50
13.50
13.50
13.50
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
14.00
13.50
—
12.15
12.00
12.15
12.45
12.15
12.55
12.10
12.45
12.15
12.45
12.15
12.45
12.15
12.45
12.15
12.65
12.10
12.45
12.10
12.45
12.10
12.70
TDR
TDR
TDR
CD5PX060
TDR&TXV
TDR
CE3AA048
13.50
14.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
14.00
—
CE3AA060
TDR
CK3BA048
TDR
CK3BA060
TDR
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
CK5PA048
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA060
—
CK5PT048
—
CK5PT060
—
CK5PW048
—
048-F
CK5PX060
—
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW048
CC5A/CD5AW060
CD5AA048
46,000
45,000
46,000
47,000
46,000
47,500
46,500
47,000
46,000
46,500
46,000
46,500
46,000
46,500
46,000
47,500
46,000
46,500
46,000
46,500
46,000
47,500
TDR
TDR
13.50
13.50
13.50
14.00
13.50
14.00
13.50
14.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
14.00
13.50
13.50
13.50
13.50
13.50
14.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.50
13.50
13.50
14.00
13.50
—
12.25
12.10
12.25
12.55
12.25
12.65
12.20
12.55
12.25
12.55
12.25
12.55
12.25
12.55
12.25
12.75
12.15
12.55
12.15
12.55
12.15
12.75
TDR
TDR
TDR
CD5PX060
TDR&TXV
TDR
CE3AA048
13.50
14.00
13.50
13.50
13.50
13.50
13.50
13.50
13.50
14.00
—
CE3AA060
TDR
CK3BA048
TDR
CK3BA060
TDR
CK5A/CK5BA048
CK5A/CK5BA060
CK5A/CK5BT048
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
CK5PA048
TDR
TDR
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PA060
—
CK5PT048
—
CK5PT060
—
CK5PW048
—
CK5PX060
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW060
CD5AA048
46,500
45,000
47,000
46,000
46,500
47,000
TDR
TDR
TDR
TDR
TDR
TDR
13.00
12.50
13.50
13.00
13.00
13.20
—
—
—
—
—
—
13.00
12.50
13.50
13.00
13.00
13.20
11.55
11.20
12.00
11.50
11.55
11.95
CE3AA048
CE3AA060
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CC5A/CD5AC048
CC5A/CD5AW060
CD5AA048
46,500
45,000
47,000
46,000
46,500
47,000
46,500
46,500
46,500
47,500
TDR
TDR
TDR
TDR
TDR
TDR
TDR
TDR
TDR
TDR
13.00
12.50
13.50
13.00
13.00
13.20
13.00
13.00
13.00
13.50
—
—
—
—
—
—
—
—
—
—
13.00
12.50
13.50
13.00
13.00
13.20
13.00
13.00
13.00
13.50
11.55
11.20
12.00
11.50
11.55
11.95
11.70
11.70
11.70
12.05
CE3AA048
CE3AA060
CK3BA060
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
See notes on page 22.
—19—
COMBINATION RATINGS Continued
SEER
FACTORY-
TOT.
CAP.
BTUH
SUPPLIED
ENHANCE-
MENT
Bryant Gas
Furnace or
Accessory TDR† Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
CK5PA060
CK5PT060
CK5PX060
46,500
46,500
47,500
TDR&TXV
TDR&TXV
TDR&TXV
13.00
13.00
13.50
—
—
—
—
—
—
11.70
11.70
12.05
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CC5A/CD5AW048
CC5A/CD5AW060
CE3AA048
46,500
46,000
47,000
46,500
47,000
46,000
46,500
46,500
46,500
46,000
47,500
46,500
46,500
46,000
47,500
TDR
TDR
13.00
13.00
13.50
13.00
13.20
13.00
13.00
13.00
13.00
13.00
13.50
13.00
13.00
13.00
13.50
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.00
13.00
13.50
13.00
13.20
13.00
13.00
13.00
13.00
13.00
13.50
—
11.55
11.50
12.00
11.55
11.95
11.60
11.80
11.80
11.80
11.60
12.15
11.80
11.80
11.60
12.15
TDR
TDR
CE3AA060
TDR
048-F
CK3BA048
CK3BA060
TDR
TDR
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BW048
CK5A/CK5BX060
CK5PA060
TDR
TDR
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
TDR&TXV
CK5PT060
—
CK5PW048
—
—
CK5PX060
See notes on page 22.
—20—
COMBINATION RATINGS Continued
SEER
FACTORY-
SUPPLIED
ENHANCE-
MENT
Bryant Gas Bryant Gas
TOT.
CAP.
BTUH
Furnace or
Accessory
TDR†
Furnace or
Accessory
TDR + TXV‡ Puron TXV‡
UNIT
SIZE-SERIES
INDOOR
MODEL
Standard
Rating
Accessory
EER
*CD5PX060
CC5A/CD5AA060
CC5A/CD5AW060
CE3AA060
59,000
56,000
58,000
58,000
58,000
58,000
58,000
59,000
58,000
58,000
59,000
58,000
59,000
58,000
59,000
59,000
57,000
59,000
59,000
59,000
TXV
NONE
—
—
13.00
—
—
12.50
12.50
13.00
12.50
12.50
12.50
13.00
—
—
—
11.05
10.65
10.90
11.00
10.95
10.95
10.95
11.10
10.95
10.95
11.10
10.70
11.05
10.70
11.05
11.75
10.80
11.75
11.75
11.05
NONE
—
—
—
NONE
—
—
—
CK3BA060
NONE
—
—
—
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
CK5PA060
NONE
—
—
—
NONE
—
—
—
NONE
—
—
—
TXV
—
12.50
12.50
13.00
—
—
CK5PT060
CK5PX060
TXV
—
—
—
TXV
—
—
—
F(A,B)4BN(F,B,C)060
FB4BNB070
TDR
—
—
12.50
13.00
—
TDR
—
—
—
FC4CN(F,B)060
FC4CNB070
TDR&TXV
TDR&TXV
TDR&TXV
NONE
12.50
13.00
13.50
—
—
—
—
—
—
FE4ANB006
—
—
—
FG3AAA060
—
12.50
—
—
FK4DNB006
TDR&TXV
TDR&TXV
TDR&TXV
13.50
13.50
13.00
—
—
FV4BNB006
—
—
—
—
FX4BNB060
—
—
COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CD5PX060
56,000
58,000
58,000
57,500
57,500
57,500
58,500
57,500
57,500
58,500
TDR
TDR&TXV
TDR
—
13.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
12.50
—
10.75
11.10
11.10
11.10
11.10
11.10
11.25
11.10
11.10
11.25
CE3AA060
13.00
13.00
13.00
13.00
13.00
—
CK3BA060
TDR
—
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
CK5PA060
TDR
—
TDR
—
TDR
—
TDR&TXV
TDR&TXV
TDR&TXV
13.00
13.00
13.00
CK5PT060
CK5PX060
—
—
COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CD5PX060
56,000
58,000
58,000
57,500
57,500
57,500
58,500
57,500
57,500
58,500
TDR
TDR&TXV
TDR
—
13.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
12.50
—
10.90
11.30
11.30
11.25
11.25
11.25
11.40
11.25
11.25
11.40
CE3AA060
13.00
13.00
13.00
13.00
13.00
—
CK3BA060
TDR
—
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
CK5PA060
TDR
—
TDR
—
060-H
TDR
—
TDR&TXV
TDR&TXV
TDR&TXV
13.00
13.00
13.00
CK5PT060
CK5PX060
—
—
COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CD5PX060
56,000
58,000
58,000
57,500
57,500
57,500
58,500
57,500
57,500
58,500
TDR
TDR&TXV
TDR
—
13.00
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
13.00
—
11.00
11.40
11.40
11.35
11.35
11.35
11.50
11.35
11.35
11.50
CE3AA060
13.00
13.00
13.00
13.00
13.00
—
CK3BA060
TDR
—
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
CK5PA060
TDR
—
TDR
—
TDR
—
TDR&TXV
TDR&TXV
TDR&TXV
13.00
13.00
13.00
CK5PT060
CK5PX060
—
—
COILS + 355MAV060080 VARIABLE-SPEED FURNACE
CK3BA060
CK5A/CK5BA060
CK5A/CK5BT060
CK5PA060
57,500
57,500
57,500
57,500
57,500
TDR
TDR
—
—
—
—
—
—
—
—
—
—
—
—
12.50
12.50
12.50
—
10.70
10.70
10.70
10.70
10.70
TDR
—
TDR&TXV
TDR&TXV
12.50
12.50
CK5PT060
—
COILS + 355MAV060100 VARIABLE-SPEED FURNACE
CK3BA060
CK5A/CK5BA060
CK5A/CK5BT060
CK5PA060
57,500
57,500
57,500
57,500
57,500
TDR
TDR
—
—
—
—
—
—
—
—
—
—
—
—
12.50
12.50
12.50
—
10.80
10.85
10.85
10.85
10.85
TDR
—
TDR&TXV
TDR&TXV
12.50
12.50
CK5PT060
—
COILS + 355MAV060120 VARIABLE-SPEED FURNACE
CC5A/CD5AA060
CK3BA060
56,000
57,500
57,500
57,500
58,500
57,500
57,500
58,500
TDR
TDR
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
12.50
12.50
12.50
12.50
13.00
—
10.55
10.90
10.95
10.95
11.05
10.95
10.95
11.05
CK5A/CK5BA060
CK5A/CK5BT060
CK5A/CK5BX060
CK5PA060
TDR
—
TDR
TDR
TDR&TXV
TDR&TXV
TDR&TXV
—
—
12.50
12.50
13.00
CK5PT060
CK5PX060
—
—
See notes on page 22.
—21—
* Tested combination.
† In most cases, only one method should be used to achieve TDR function. Using more than one method in a system may cause degradation in performance.
Use either the accessory Time-Delay Relay KAATD0101TDR or a furnace equipped with TDR. Most Bryant furnaces are equipped with TDR.
‡ TXV must be Puron compatible and hard shutoff type.
EER — Energy Efficiency Ratio
LLS
— Liquid-Line Solenoid Valve
SEER — Seasonal Energy Efficiency Ratio
TDR — Time-Delay Relay
TXV
— Thermostatic Expansion Valve
NOTES: 1. Ratings are net values reflecting the effects of circulating fan motor heat. Supplemental electric heat is not included.
2. Tested outdoor/indoor combinations have been tested in accordance with DOE test procedures for electric air conditioners. Ratings for other com-
binations are determined under DOE computer simulation procedures.
3. Determine actual CFM values obtainable for your system by referring to fan performance data in fan coil or furnace coil literature.
4. Do not apply with capillary tube coils as performance and reliability are significantly affected.
—22—
DETAILED COOLING CAPACITIES*
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A024-G Outdoor Section With CC5A/CD5AA030 Indoor Section
57
62
67
72
21.18 21.18 1.55 20.24 20.24 1.75 19.29 19.29 1.98 18.25 18.25 2.22 17.12 17.12 2.47 15.93 15.93 2.75
22.64 20.05 1.55 21.22 19.43 1.77 19.94 18.79 1.99 18.56 18.06 2.22 17.12 17.12 2.47 15.93 15.93 2.75
24.77 16.75 1.56 23.85 16.60 1.78 22.47 16.09 2.02 21.00 15.48 2.28 19.45 14.85 2.53 17.78 14.18 2.81
25.81 13.18 1.58 25.61 13.23 1.79 24.84 13.05 2.03 23.58 12.61 2.29 22.06 12.07 2.57 20.37 11.46 2.87
700
800
900
57
62
67
72
57
62
67
72
22.22 22.22 1.58 21.17 21.17 1.80 20.15 20.15 2.03 19.06 19.06 2.27 17.91 17.91 2.53 16.64 16.64 2.81
23.20 21.31 1.59 21.76 20.74 1.81 20.42 20.01 2.03 19.06 19.06 2.27 17.91 17.91 2.53 16.64 16.64 2.81
25.02 17.33 1.60 24.32 17.46 1.81 23.00 17.09 2.05 21.46 16.52 2.32 19.85 15.87 2.58 18.15 15.19 2.86
25.88 13.37 1.62 25.75 13.52 1.83 25.15 13.50 2.07 23.95 13.15 2.33 22.44 12.65 2.61 20.72 12.06 2.91
23.03 23.03 1.62 22.01 22.01 1.84 20.90 20.90 2.07 19.81 19.81 2.32 18.59 18.59 2.59 17.27 17.27 2.87
23.64 22.41 1.63 22.28 21.90 1.84 20.89 20.89 2.07 19.80 19.80 2.32 18.58 18.58 2.59 17.27 17.27 2.87
25.15 17.80 1.64 24.64 18.20 1.85 23.38 18.01 2.09 21.84 17.50 2.35 20.17 16.86 2.63 18.42 16.15 2.91
25.90 13.52 1.65 25.81 13.75 1.87 25.31 13.85 2.11 24.19 13.62 2.37 22.71 13.17 2.64 20.99 12.62 2.95
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Indoor
Section
Size
024
030
024
030
024
030
024
024
030
024
030
024
030
024
030
024
030
024
030
024
030
002
003
024
030
024
030
024
001
002
003
002
003
030
Capacity
0.99
1.00
0.99
1.00
0.99
1.00
0.99
0.99
1.00
0.99
1.00
0.99
1.00
0.99
1.00
0.99
1.00
1.00
1.02
1.00
1.02
1.03
1.03
1.00
1.02
1.00
1.02
0.96
1.02
1.03
1.03
1.03
1.03
1.02
Power
1.00
1.00
1.00
1.00
0.99
0.99
1.00
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
1.00
0.99
0.99
0.90
0.89
1.00
1.01
1.00
1.01
0.98
0.90
0.90
0.89
0.90
0.89
0.98
Section
Size
024
030
024
030
024
030
024
030
024
030
Capacity
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
Power
0.88
0.89
0.89
0.90
0.89
0.89
0.89
0.90
0.89
0.90
CC5A/CD5AA
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BW
CK5PA
CF5AA
CK3BA
CK5PW
0.97
0.99
CK5A/CK5BA
CK5A/CK5BW
CK5PA
COILS + 315(A,J)AV048090 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
024
030
024
030
024
030
024
030
024
030
024
030
024
030
024
030
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.89
0.89
0.89
0.89
0.89
0.89
0.87
0.88
0.88
0.89
0.88
0.89
0.89
0.89
0.88
0.89
CK5PW
F(A,B)4BN(F,C)
FC4CNF
CK3BA
CK5A/CK5BA
CK5A/CK5BW
CK5PA
FE4ANF
FF1DNA
FF1DNE
CK5PW
FG3AAA
FK4DNF
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AW
024
030
024
030
024
030
024
030
024
030
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.89
0.90
0.90
0.89
0.87
0.89
0.89
0.89
0.89
0.90
CE3AA
FV4BNF
FX4BNF
CK3BA
CK5A/CK5BW
CK5PW
COILS + 315(A,J)AV036070 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
024
030
024
030
024
030
0.97
0.99
0.97
0.99
0.97
0.99
0.90
0.90
0.90
0.90
0.89
0.90
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CE3AA
024
030
0.97
0.99
0.89
0.89
See notes on page 38.
—23—
DETAILED COOLING CAPACITIES* continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A024-G Outdoor Section With CC5A/CD5AA030 Indoor Section continued
57
62
67
72
21.18 21.18 1.55 20.24 20.24 1.75 19.29 19.29 1.98 18.25 18.25 2.22 17.12 17.12 2.47 15.93 15.93 2.75
22.64 20.05 1.55 21.22 19.43 1.77 19.94 18.79 1.99 18.56 18.06 2.22 17.12 17.12 2.47 15.93 15.93 2.75
24.77 16.75 1.56 23.85 16.60 1.78 22.47 16.09 2.02 21.00 15.48 2.28 19.45 14.85 2.53 17.78 14.18 2.81
25.81 13.18 1.58 25.61 13.23 1.79 24.84 13.05 2.03 23.58 12.61 2.29 22.06 12.07 2.57 20.37 11.46 2.87
700
800
900
57
62
67
72
57
62
67
72
22.22 22.22 1.58 21.17 21.17 1.80 20.15 20.15 2.03 19.06 19.06 2.27 17.91 17.91 2.53 16.64 16.64 2.81
23.20 21.31 1.59 21.76 20.74 1.81 20.42 20.01 2.03 19.06 19.06 2.27 17.91 17.91 2.53 16.64 16.64 2.81
25.02 17.33 1.60 24.32 17.46 1.81 23.00 17.09 2.05 21.46 16.52 2.32 19.85 15.87 2.58 18.15 15.19 2.86
25.88 13.37 1.62 25.75 13.52 1.83 25.15 13.50 2.07 23.95 13.15 2.33 22.44 12.65 2.61 20.72 12.06 2.91
23.03 23.03 1.62 22.01 22.01 1.84 20.90 20.90 2.07 19.81 19.81 2.32 18.59 18.59 2.59 17.27 17.27 2.87
23.64 22.41 1.63 22.28 21.90 1.84 20.89 20.89 2.07 19.80 19.80 2.32 18.58 18.58 2.59 17.27 17.27 2.87
25.15 17.80 1.64 24.64 18.20 1.85 23.38 18.01 2.09 21.84 17.50 2.35 20.17 16.86 2.63 18.42 16.15 2.91
25.90 13.52 1.65 25.81 13.75 1.87 25.31 13.85 2.11 24.19 13.62 2.37 22.71 13.17 2.64 20.99 12.62 2.95
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Indoor
Section
Size
Capacity
Power
Section
Size
024
030
024
030
Capacity
0.97
0.99
0.97
0.99
Power
0.89
0.89
0.89
0.90
CK5A/CK5BW
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CE3AA
024
030
0.97
0.99
0.89
0.89
CK5PW
COILS + 355MAV042040 VARIABLE SPEED FURNACE
CE3AA
024
0.97
0.90
COILS + 355MAV060080 VARIABLE SPEED FURNACE
030
0.99
0.90
CC5A/CD5AW
024
030
024
030
024
030
024
030
024
030
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.89
0.90
0.89
0.90
0.88
0.89
0.88
0.89
0.89
0.90
COILS + 355MAV042060 VARIABLE SPEED FURNACE
CC5A/CD5AA
024
030
024
030
024
030
024
030
024
030
024
030
024
030
024
030
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.90
0.90
0.89
0.90
0.89
0.90
0.87
0.89
0.89
0.90
0.88
0.89
0.89
0.90
0.89
0.90
CE3AA
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BW
CK5PW
CK3BA
CK5A/CK5BA
CK5A/CK5BW
CK5PA
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CC5A/CD5AW
024
030
024
030
024
030
024
030
024
030
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.97
0.99
0.89
0.90
0.89
0.89
0.87
0.89
0.88
0.89
0.89
0.90
CE3AA
CK3BA
CK5PW
CK5A/CK5BW
CK5PW
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CC5A/CD5AW
024
030
024
030
024
030
0.97
0.99
0.97
0.99
0.97
0.99
0.90
0.90
0.90
0.90
0.88
0.89
CE3AA
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CE3AA
024
030
—
0.97
0.99
—
0.90
0.90
—
CK3BA
See notes on page 38.
—24—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A030-F Outdoor Section With CC5A/CD5AA036 Indoor Section
72
67
33.4
31.4
16.3
21.2
20.9
25.7
26.6
1.80
1.79
1.77
1.77
1.75
32.2
30.0
27.8
26.6
25.1
15.9
20.7
20.2
24.7
25.1
1.99
1.97
1.96
1.95
1.93
31.1
28.6
25.1
24.5
23.6
15.6
20.1
19.0
23.6
23.6
2.21
2.19
2.15
2.15
2.14
29.7
27.0
22.3
22.3
21.9
15.2
19.6
17.8
22.3
21.9
2.46
2.43
2.37
2.37
2.37
27.9
24.5
20.4
20.5
20.8
14.5
18.6
17.0
20.5
20.8
2.73
2.69
2.63
2.63
2.63
26.0
21.7
18.2
19.4
19.6
13.9
17.5
16.1
19.4
19.6
3.05
2.97
2.91
2.93
2.93
1875
1000
1125
63†† 29.4
62
57
28.6
26.6
72
67
33.9
31.9
16.9
22.3
22.1
27.5
27.9
17.4
23.3
23.1
29.0
29.5
1.85
1.83
1.82
1.81
1.80
1.89
1.87
1.86
1.86
1.85
32.7
30.5
28.5
27.2
26.4
33.0
30.8
29.0
28.1
28.2
16.5
21.8
21.5
26.4
26.4
17.1
22.9
22.7
27.9
28.2
2.04
2.02
2.00
1.99
1.99
2.08
2.06
2.05
2.04
2.04
31.6
29.0
25.8
25.1
24.7
31.7
29.3
26.3
26.6
26.6
16.3
21.3
20.3
25.1
24.7
16.7
22.4
21.6
26.6
26.6
2.26
2.23
2.20
2.19
2.19
2.30
2.27
2.25
2.25
2.25
30.0
27.4
23.1
23.3
23.7
30.1
27.7
24.1
25.1
25.3
15.8
20.8
19.2
23.3
23.7
16.3
22.0
20.6
25.1
25.3
2.50
2.47
2.42
2.43
2.43
2.54
2.51
2.47
2.49
2.49
28.2
25.2
21.1
22.3
22.6
28.5
25.7
21.8
23.8
23.5
15.2
20.0
18.3
22.3
22.6
15.9
21.3
19.6
23.8
23.5
2.78
2.74
2.68
2.69
2.70
2.82
2.78
2.73
2.75
2.75
26.3
22.3
18.9
20.3
20.4
26.5
22.7
19.6
21.2
21.1
14.7
18.9
17.4
20.3
20.4
15.4
20.2
18.7
21.2
21.1
3.10
3.02
2.96
2.99
2.99
3.15
3.07
3.01
3.04
3.04
63†† 30.0
62
57
72
67
29.4
27.9
34.2
32.2
63†† 30.3
62
57
29.9
29.5
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Indoor
Section
Size
Capacity
0.97
1.00
0.97
1.00
0.97
0.98
0.98
0.97
1.00
0.97
1.00
1.00
0.97
1.00
0.97
1.00
1.00
0.97
1.00
0.99
1.00
1.00
1.02
0.99
0.98
0.99
1.00
1.02
1.00
1.02
0.99
1.00
Power
1.00
1.00
1.00
1.00
0.98
0.99
0.98
0.99
1.00
0.99
1.00
1.00
0.99
1.00
0.99
1.00
1.00
0.99
1.00
1.00
1.02
0.93
0.91
1.00
1.00
0.91
0.93
0.92
0.93
0.91
1.00
1.02
Section
CK5A/CK5BT
CK5A/CK5BW
CK5PA
Size
036
030
030
036
036
030
Capacity
1.00
0.97
0.99
1.00
Power
0.93
0.92
0.94
0.93
0.93
0.94
CC5A/CD5AA
CC5A/CD5AW
CE3AA
030
036
030
036
030
036
036
030
036
030
036
036
030
036
030
036
036
030
036
030
036
002
003
030
036
001
002
003
002
003
030
036
CK5PT
CK5PW
1.00
0.99
CF5AA
CK3BA
COILS + 315(A,J)AV048090 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
030
036
030
036
030
036
030
036
030
036
030
036
030
036
36
0.97
1.00
0.97
1.00
0.99
0.99
0.97
1.00
0.97
1.00
0.99
1.00
0.99
1.00
1.00
0.99
1.00
0.92
0.92
0.92
0.92
0.93
0.92
0.91
0.92
0.91
0.92
0.93
0.92
0.94
0.92
0.92
0.94
0.92
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK3BA
CK5PA
CK5A/CK5BA
CK5A/CK5BW
CK5PA
CK5PT
CK5PW
F(A,B)4(A,B)N(F,C)
FE4ANF
CK5PT
CK5PW
030
036
FF1DNA
FG3AAA
FK4(C,D)NF
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
036
030
036
030
036
030
036
036
036
030
036
036
036
030
036
1.00
0.97
1.00
0.99
1.00
0.99
1.00
1.00
1.00
0.99
1.00
1.00
1.00
0.99
1.00
0.90
0.90
0.90
0.91
0.91
0.90
0.90
0.90
0.90
0.91
0.90
0.90
0.90
0.91
0.90
FV4(A,B)NF
FX4(A,B)NF
CE3AA
CK3BA
COILS + 315(A,J)AV036070 VARIABLE SPEED FURNACE
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CC5A/CD5AA
030
036
030
030
036
030
036
0.97
1.00
0.97
0.98
0.99
0.97
1.00
0.93
0.93
0.93
0.93
0.93
0.92
0.93
CC5A/CD5AW
CE3AA
CK5PA
CK5PT
CK5PW
CK3BA
See notes on page 38.
—25—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
,
550A030-F Outdoor Section With CC5A/CD5AA036 Indoor Section Continued
72
67
33.4
31.4
16.3
21.2
20.9
25.7
26.6
1.80
1.79
1.77
1.77
1.75
32.2
30.0
27.8
26.6
25.1
15.9
20.7
20.2
24.7
25.1
1.99
1.97
1.96
1.95
1.93
31.1
28.6
25.1
24.5
23.6
15.6
20.1
19.0
23.6
23.6
2.21
2.19
2.15
2.15
2.14
29.7
27.0
22.3
22.3
21.9
15.2
19.6
17.8
22.3
21.9
2.46
2.43
2.37
2.37
2.37
27.9
24.5
20.4
20.5
20.8
14.5
18.6
17.0
20.5
20.8
2.73
2.69
2.63
2.63
2.63
26.0
21.7
18.2
19.4
19.6
13.9
17.5
16.1
19.4
19.6
3.05
2.97
2.91
2.93
2.93
1875
1000
1125
63†† 29.4
62
57
28.6
26.6
72
67
33.9
31.9
16.9
22.3
22.1
27.5
27.9
17.4
23.3
23.1
29.0
29.5
1.85
1.83
1.82
1.81
1.80
1.89
1.87
1.86
1.86
1.85
32.7
30.5
28.5
27.2
26.4
33.0
30.8
29.0
28.1
28.2
16.5
21.8
21.5
26.4
26.4
17.1
22.9
22.7
27.9
28.2
2.04
2.02
2.00
1.99
1.99
2.08
2.06
2.05
2.04
2.04
31.6
29.0
25.8
25.1
24.7
31.7
29.3
26.3
26.6
26.6
16.3
21.3
20.3
25.1
24.7
16.7
22.4
21.6
26.6
26.6
2.26
2.23
2.20
2.19
2.19
2.30
2.27
2.25
2.25
2.25
30.0
27.4
23.1
23.3
23.7
30.1
27.7
24.1
25.1
25.3
15.8
20.8
19.2
23.3
23.7
16.3
22.0
20.6
25.1
25.3
2.50
2.47
2.42
2.43
2.43
2.54
2.51
2.47
2.49
2.49
28.2
25.2
21.1
22.3
22.6
28.5
25.7
21.8
23.8
23.5
15.2
20.0
18.3
22.3
22.6
15.9
21.3
19.6
23.8
23.5
2.78
2.74
2.68
2.69
2.70
2.82
2.78
2.73
2.75
2.75
26.3
22.3
18.9
20.3
20.4
26.5
22.7
19.6
21.2
21.1
14.7
18.9
17.4
20.3
20.4
15.4
20.2
18.7
21.2
21.1
3.10
3.02
2.96
2.99
2.99
3.15
3.07
3.01
3.04
3.04
63†† 30.0
62
57
72
67
29.4
27.9
34.2
32.2
63†† 30.3
62
57
29.9
29.5
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
COILS + 355MAV042060 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CK3BA
036
030
030
036
036
036
030
036
036
030
1.02
0.98
0.98
1.02
1.02
1.02
0.98
1.02
1.02
0.98
0.96
0.95
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
CC5A/CD5AW
036
030
036
036
036
1.00
0.99
1.00
1.00
1.00
0.89
0.90
0.90
0.89
0.89
CE3AA
CK5A/CK5BW
CK5PW
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AW
CE3AA
036
030
036
036
036
1.00
0.99
1.00
1.00
1.00
0.89
0.90
0.90
0.88
0.89
CK5PT
CK5PW
CK5A/CK5BW
CK5PW
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CC5A/CD5AW
030
036
030
036
030
036
030
036
030
036
—
0.99
1.02
1.00
1.01
0.99
1.02
0.99
1.02
0.99
1.02
—
0.95
0.94
0.95
0.95
0.96
0.94
0.96
0.94
0.96
0.94
—
COILS + 355MAV042040 VARIABLE SPEED FURNACE
CC5A/CD5AW
030
036
030
036
030
036
030
036
030
036
0.98
1.02
1.00
1.01
0.98
1.02
0.98
1.02
0.98
1.02
0.95
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
0.96
CE3AA
CE3AA
CK3BA
CK3BA
CK5A/CK5BW
CK5PW
CK5A/CK5BW
CK5PW
See notes on page 38.
—26—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A036-F Outdoor Section With CC5A/CD5AA042 Indoor Section
72
67
40.4
38.0
19.6
25.3
24.6
30.2
31.3
2.15
2.14
2.12
2.12
2.09
39.0
36.4
32.5
31.6
29.5
19.2
24.8
23.6
29.1
29.5
2.40
2.38
2.35
2.34
2.32
37.4
34.6
30.1
29.2
27.5
18.6
24.1
22.5
27.9
27.5
2.66
2.65
2.60
2.59
2.57
35.6
32.5
27.5
26.7
26.4
18.0
23.3
21.4
26.5
26.4
2.96
2.94
2.87
2.86
2.86
33.4
30.4
24.9
24.5
25.1
17.3
22.4
20.3
24.5
25.1
3.28
3.24
3.17
3.17
3.17
30.9
26.5
22.3
23.2
23.6
16.4
20.9
19.2
23.2
23.6
3.64
3.57
3.50
3.51
3.51
1050
1200
1350
63†† 34.9
62
57
33.9
31.3
72
67
41.0
38.5
20.3
26.5
26.3
32.4
32.7
20.9
27.8
27.8
34.5
34.8
2.20
2.19
2.18
2.17
2.15
2.25
2.24
2.23
2.22
2.22
39.7
37.0
33.6
32.4
31.0
40.2
37.4
34.5
33.2
33.3
19.9
26.1
25.2
31.2
31.0
20.6
27.3
26.8
32.9
33.3
2.45
2.43
2.41
2.39
2.38
2.50
2.48
2.46
2.45
2.45
38.1
35.0
31.1
30.0
29.9
38.2
35.5
31.9
31.1
32.0
19.4
25.3
24.1
29.7
29.9
19.9
26.7
25.7
31.1
32.0
2.72
2.69
2.66
2.65
2.64
2.76
2.74
2.71
2.70
2.72
36.2
33.1
28.3
27.9
28.7
36.4
33.5
29.4
30.0
30.7
18.9
24.7
23.0
27.9
28.7
19.4
26.1
24.6
30.0
30.7
3.02
2.99
2.93
2.93
2.94
3.06
3.03
2.99
3.00
3.01
33.9
30.9
26.0
26.8
27.3
34.2
31.2
26.9
28.6
28.3
18.1
23.9
22.0
26.8
27.3
18.8
25.4
23.6
28.6
28.3
3.34
3.30
3.24
3.25
3.25
3.38
3.35
3.30
3.32
3.32
31.4
26.9
23.3
24.6
24.8
31.7
27.2
24.2
25.8
25.9
17.3
22.4
20.9
24.6
24.8
18.2
23.8
22.4
25.8
25.9
3.70
3.62
3.56
3.58
3.58
3.75
3.68
3.62
3.65
3.65
63†† 36.1
62
57
72
67
34.8
32.7
41.4
39.0
63†† 36.9
62
57
35.8
34.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CC5A/CD5AA
036
042
036
036
042
036
036
042
036
042
036
042
036
036
042
036
042
036
042
036
002
003
005
036
002
003
005
002
003
005
036
042
1.00
1.00
CK5PT
036
1.00
0.94
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.03
1.00
1.00
1.00
1.03
1.00
1.00
1.03
0.97
1.00
1.00
1.00
1.01
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.93
0.94
1.02
0.95
0.93
0.94
0.95
0.93
0.94
0.99
1.00
COILS + 315(A,J)AV048090 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
036
042
036
036
042
036
042
036
042
042
036
042
036
036
042
042
036
042
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.93
0.92
0.93
0.94
0.92
0.93
0.92
0.93
0.92
0.92
0.93
0.92
0.93
0.93
0.92
0.92
0.93
0.92
0.93
CC5A/CD5AW
CE3AA
CF5AA
CK3BA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BA
CK5A/CK5BE
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5A/CK5BW
CK5PA
CK5PT
CK5PW
F(A,B)4(A,B)N(F,B,C)
F(A,B)4(A,B)N(F,C)
FE4ANF
CK5PE
CK5PT
CK5PW
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
036
042
036
042
036
042
036
042
036
042
042
036
042
036
036
042
036
042
036
042
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.93
0.93
0.93
0.94
0.94
0.92
0.93
0.93
0.93
0.93
0.92
0.93
0.93
0.93
0.93
0.93
0.93
0.93
0.93
0.92
FG3AAA
FK4(C,D)NF
FV4(A,B)NF
FX4(A,B)NF
CK3BA
CK5A/CK5BA
COILS + 315(A,J)AV036070 VARIABLE SPEED FURNACE
CC5A/CD5AA
CK5A/CK5BE
CK5A/CK5BT
036
036
042
036
036
042
036
036
042
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.96
0.94
0.94
0.94
0.93
0.94
0.94
0.93
CE3AA
CK5A/CK5BW
CK5PA
CK3BA
CK5A/CK5BA
CK5A/CK5BE
CK5A/CK5BT
CK5PA
CK5PT
CK5PW
CK5PE
CK5PE
See notes on page 38.
—27—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A036-F Outdoor Section With CC5A/CD5AA042 Indoor Section continued
72
67
40.4
38.0
19.6
25.3
24.6
30.2
31.3
2.15
2.14
2.12
2.12
2.09
39.0
36.4
32.5
31.6
29.5
19.2
24.8
23.6
29.1
29.5
2.40
2.38
2.35
2.34
2.32
37.4
34.6
30.1
29.2
27.5
18.6
24.1
22.5
27.9
27.5
2.66
2.65
2.60
2.59
2.57
35.6
32.5
27.5
26.7
26.4
18.0
23.3
21.4
26.5
26.4
2.96
2.94
2.87
2.86
2.86
33.4
30.4
24.9
24.5
25.1
17.3
22.4
20.3
24.5
25.1
3.28
3.24
3.17
3.17
3.17
30.9
26.5
22.3
23.2
23.6
16.4
20.9
19.2
23.2
23.6
3.64
3.57
3.50
3.51
3.51
1050
1200
1350
63†† 34.9
62
57
33.9
31.3
72
67
41.0
38.5
20.3
26.5
26.3
32.4
32.7
20.9
27.8
27.8
34.5
34.8
2.20
2.19
2.18
2.17
2.15
2.25
2.24
2.23
2.22
2.22
39.7
37.0
33.6
32.4
31.0
40.2
37.4
34.5
33.2
33.3
19.9
26.1
25.2
31.2
31.0
20.6
27.3
26.8
32.9
33.3
2.45
2.43
2.41
2.39
2.38
2.50
2.48
2.46
2.45
2.45
38.1
35.0
31.1
30.0
29.9
38.2
35.5
31.9
31.1
32.0
19.4
25.3
24.1
29.7
29.9
19.9
26.7
25.7
31.1
32.0
2.72
2.69
2.66
2.65
2.64
2.76
2.74
2.71
2.70
2.72
36.2
33.1
28.3
27.9
28.7
36.4
33.5
29.4
30.0
30.7
18.9
24.7
23.0
27.9
28.7
19.4
26.1
24.6
30.0
30.7
3.02
2.99
2.93
2.93
2.94
3.06
3.03
2.99
3.00
3.01
33.9
30.9
26.0
26.8
27.3
34.2
31.2
26.9
28.6
28.3
18.1
23.9
22.0
26.8
27.3
18.8
25.4
23.6
28.6
28.3
3.34
3.30
3.24
3.25
3.25
3.38
3.35
3.30
3.32
3.32
31.4
26.9
23.3
24.6
24.8
31.7
27.2
24.2
25.8
25.9
17.3
22.4
20.9
24.6
24.8
18.2
23.8
22.4
25.8
25.9
3.70
3.62
3.56
3.58
3.58
3.75
3.68
3.62
3.65
3.65
63†† 36.1
62
57
72
67
34.8
32.7
41.4
39.0
63†† 36.9
62
57
35.8
34.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CE3AA
036
1.00
0.99
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CC5A/CD5AA
042
036
042
036
042
042
042
042
036
042
042
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.92
0.93
0.92
0.94
0.92
0.92
0.92
0.92
0.93
0.92
0.92
0.93
042
036
042
036
036
036
036
036
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
0.97
CC5A/CD5AW
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5PT
CK5PW
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CK5PT
CK5PW
CC5A/CD5AA
CC5A/CD5AW
CE3AA
042
036
036
042
036
042
042
042
036
042
042
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.96
0.97
0.95
0.97
0.95
0.95
0.95
0.97
0.95
0.95
0.97
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
042
036
042
036
042
042
042
042
036
042
042
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.91
0.93
0.91
0.93
0.91
0.91
0.91
0.91
0.92
0.91
0.91
0.92
CK3BA
CE3AA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5PT
CK5PW
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CK5PT
CK5PW
CC5A/CD5AA
CC5A/CD5AW
CE3AA
042
036
036
042
036
042
042
042
036
042
042
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.94
0.95
0.97
0.94
0.98
0.97
0.97
0.97
0.98
0.97
0.97
0.98
COILS + 355MAV042040 VARIABLE SPEED FURNACE
CC5A/CD5AA
042
036
042
036
042
042
042
036
042
042
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.97
0.99
0.97
0.98
0.98
0.98
0.98
0.98
0.98
0.98
0.98
CE3AA
CK3BA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5PT
CK5PW
CK5PT
CK5PW
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
042
036
036
042
1.00
1.00
1.00
1.00
0.94
0.95
0.97
0.94
COILS + 355MAV042060 VARIABLE SPEED FURNACE
CC5A/CD5AA
036
—
1.00
—
0.98
—
See notes on page 38.
—28—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A036-F Outdoor Section With CC5A/CD5AA042 Indoor Section continued
72
67
40.4
38.0
19.6
25.3
24.6
30.2
31.3
2.15
2.14
2.12
2.12
2.09
39.0
36.4
32.5
31.6
29.5
19.2
24.8
23.6
29.1
29.5
2.40
2.38
2.35
2.34
2.32
37.4
34.6
30.1
29.2
27.5
18.6
24.1
22.5
27.9
27.5
2.66
2.65
2.60
2.59
2.57
35.6
32.5
27.5
26.7
26.4
18.0
23.3
21.4
26.5
26.4
2.96
2.94
2.87
2.86
2.86
33.4
30.4
24.9
24.5
25.1
17.3
22.4
20.3
24.5
25.1
3.28
3.24
3.17
3.17
3.17
30.9
26.5
22.3
23.2
23.6
16.4
20.9
19.2
23.2
23.6
3.64
3.57
3.50
3.51
3.51
1050
1200
1350
63†† 34.9
62
57
33.9
31.3
72
67
41.0
38.5
20.3
26.5
26.3
32.4
32.7
20.9
27.8
27.8
34.5
34.8
2.20
2.19
2.18
2.17
2.15
2.25
2.24
2.23
2.22
2.22
39.7
37.0
33.6
32.4
31.0
40.2
37.4
34.5
33.2
33.3
19.9
26.1
25.2
31.2
31.0
20.6
27.3
26.8
32.9
33.3
2.45
2.43
2.41
2.39
2.38
2.50
2.48
2.46
2.45
2.45
38.1
35.0
31.1
30.0
29.9
38.2
35.5
31.9
31.1
32.0
19.4
25.3
24.1
29.7
29.9
19.9
26.7
25.7
31.1
32.0
2.72
2.69
2.66
2.65
2.64
2.76
2.74
2.71
2.70
2.72
36.2
33.1
28.3
27.9
28.7
36.4
33.5
29.4
30.0
30.7
18.9
24.7
23.0
27.9
28.7
19.4
26.1
24.6
30.0
30.7
3.02
2.99
2.93
2.93
2.94
3.06
3.03
2.99
3.00
3.01
33.9
30.9
26.0
26.8
27.3
34.2
31.2
26.9
28.6
28.3
18.1
23.9
22.0
26.8
27.3
18.8
25.4
23.6
28.6
28.3
3.34
3.30
3.24
3.25
3.25
3.38
3.35
3.30
3.32
3.32
31.4
26.9
23.3
24.6
24.8
31.7
27.2
24.2
25.8
25.9
17.3
22.4
20.9
24.6
24.8
18.2
23.8
22.4
25.8
25.9
3.70
3.62
3.56
3.58
3.58
3.75
3.68
3.62
3.65
3.65
63†† 36.1
62
57
72
67
34.8
32.7
41.4
39.0
63†† 36.9
62
57
35.8
34.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CK3BA
036
042
042
042
036
042
042
036
1.00
0.95
CC5A/CD5AW
CE3AA
036
1.00
0.95
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.93
0.93
0.93
0.95
0.93
0.93
0.95
036
042
036
042
042
042
036
042
042
036
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.97
0.94
0.95
0.93
0.93
0.93
0.95
0.93
0.93
0.95
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5PT
CK5PW
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AA
042
—
1.00
—
0.94
—
CK5PT
CK5PW
See notes on page 38.
—29—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A036-G Outdoor Section With CC5A/CD5AA042 Indoor Section
72
67
40.4
38.0
19.6
25.3
24.6
30.2
31.3
2.15
2.14
2.12
2.12
2.09
39.0
36.4
32.5
31.6
29.5
19.2
24.8
23.6
29.1
29.5
2.40
2.38
2.35
2.34
2.32
37.4
34.6
30.1
29.2
27.5
18.6
24.1
22.5
27.9
27.5
2.66
2.65
2.60
2.59
2.57
35.6
32.5
27.5
26.7
26.4
18.0
23.3
21.4
26.5
26.4
2.96
2.94
2.87
2.86
2.86
33.4
30.4
24.9
24.5
25.1
17.3
22.4
20.3
24.5
25.1
3.28
3.24
3.17
3.17
3.17
30.9
26.5
22.3
23.2
23.6
16.4
20.9
19.2
23.2
23.6
3.64
3.57
3.50
3.51
3.51
1050
1200
1350
63†† 34.9
62
57
33.9
31.3
72
67
41.0
38.5
20.3
26.5
26.3
32.4
32.7
20.9
27.8
27.8
34.5
34.8
2.20
2.19
2.18
2.17
2.15
2.25
2.24
2.23
2.22
2.22
39.7
37.0
33.6
32.4
31.0
40.2
37.4
34.5
33.2
33.3
19.9
26.1
25.2
31.2
31.0
20.6
27.3
26.8
32.9
33.3
2.45
2.43
2.41
2.39
2.38
2.50
2.48
2.46
2.45
2.45
38.1
35.0
31.1
30.0
29.9
38.2
35.5
31.9
31.1
32.0
19.4
25.3
24.1
29.7
29.9
19.9
26.7
25.7
31.1
32.0
2.72
2.69
2.66
2.65
2.64
2.76
2.74
2.71
2.70
2.72
36.2
33.1
28.3
27.9
28.7
36.4
33.5
29.4
30.0
30.7
18.9
24.7
23.0
27.9
28.7
19.4
26.1
24.6
30.0
30.7
3.02
2.99
2.93
2.93
2.94
3.06
3.03
2.99
3.00
3.01
33.9
30.9
26.0
26.8
27.3
34.2
31.2
26.9
28.6
28.3
18.1
23.9
22.0
26.8
27.3
18.8
25.4
23.6
28.6
28.3
3.34
3.30
3.24
3.25
3.25
3.38
3.35
3.30
3.32
3.32
31.4
26.9
23.3
24.6
24.8
31.7
27.2
24.2
25.8
25.9
17.3
22.4
20.9
24.6
24.8
18.2
23.8
22.4
25.8
25.9
3.70
3.62
3.56
3.58
3.58
3.75
3.68
3.62
3.65
3.65
63†† 36.1
62
57
72
67
34.8
32.7
41.4
39.0
63†† 36.9
62
57
35.8
34.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CC5A/CD5AA
CC5A/CD5AW
CE3AA
036*
042
036
042
036
042
036
036
042
036
042
042
036
042
036
036
042
042
036
042
036
042
036
042
036
006
002
003
005
036
048
006
001
002
003
005
006
002
003
005
036
042
1.00
1.00
COILS + 315(A,J)AV036070 VARIABLE SPEED FURNACE
1.00
1.00
0.99
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.99
1.00
0.99
1.03
1.00
1.00
1.03
0.97
1.00
1.03
0.99
1.00
1.00
1.03
1.03
1.00
1.00
1.03
1.00
1.02
1.00
1.00
1.00
1.00
0.99
1.00
1.00
1.00
1.00
1.00
0.99
1.00
1.00
1.00
1.00
1.00
0.99
1.00
1.00
1.00
1.01
1.02
1.00
1.02
0.89
0.94
0.91
0.90
1.00
1.01
0.89
0.95
0.94
0.91
0.90
0.89
0.94
0.91
0.90
1.01
1.01
CC5A/CD5AA
036
036
042
036
036
042
036
036
042
036
0.98
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.93
0.93
0.93
0.93
0.93
0.93
0.93
0.94
0.93
0.94
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BE
CK5A/CK5BT
CK5PA
CF5AA
CK3BA
CK5A/CK5BA
CK5PE
CK5PT
CK5A/CK5BE
CK5A/CK5BT
COILS + 315(A,J)AV048090 VARIABLE SPEED FURNACE
CC5A/CD5AA
036
042
036
036
042
036
042
036
042
042
036
042
036
036
042
042
036
042
036
0.98
0.98
0.98
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.92
0.91
0.91
0.92
0.91
0.92
0.92
0.92
0.92
0.91
0.92
0.92
0.92
0.92
0.92
0.91
0.92
0.92
0.92
CK5A/CK5BW
CK5PA
CC5A/CD5AW
CE3AA
CK5PE
CK5PT
CK3BA
CK5A/CK5BA
CK5PW
F(A,B)4BN(F,B,C)
F(A,B)4BN(F,C)
FC4CN(F,B)
FC4CNF
CK5A/CK5BE
CK5A/CK5BT
CK5A/CK5BW
CK5PA
FE4ANB
FE4ANF
CK5PE
CK5PT
FG3AAA
CK5PW
FK4DNB
FK4DNF
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
036
042
036
042
036
042
036
042
036
042
0.98
0.98
0.98
0.98
0.97
0.99
0.99
0.99
0.99
0.99
0.92
0.91
0.91
0.91
0.92
0.91
0.92
0.92
0.92
0.92
FV4BNB
FV4BNF
CK3BA
FX4BNF
CK5A/CK5BA
See notes on page 38.
—30—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A036-G Outdoor Section With CC5A/CD5AA042 Indoor Section continued
72
67
40.4
38.0
19.6
25.3
24.6
30.2
31.3
2.15
2.14
2.12
2.12
2.09
39.0
36.4
32.5
31.6
29.5
19.2
24.8
23.6
29.1
29.5
2.40
2.38
2.35
2.34
2.32
37.4
34.6
30.1
29.2
27.5
18.6
24.1
22.5
27.9
27.5
2.66
2.65
2.60
2.59
2.57
35.6
32.5
27.5
26.7
26.4
18.0
23.3
21.4
26.5
26.4
2.96
2.94
2.87
2.86
2.86
33.4
30.4
24.9
24.5
25.1
17.3
22.4
20.3
24.5
25.1
3.28
3.24
3.17
3.17
3.17
30.9
26.5
22.3
23.2
23.6
16.4
20.9
19.2
23.2
23.6
3.64
3.57
3.50
3.51
3.51
1050
1200
1350
63†† 34.9
62
57
33.9
31.3
72
67
41.0
38.5
20.3
26.5
26.3
32.4
32.7
20.9
27.8
27.8
34.5
34.8
2.20
2.19
2.18
2.17
2.15
2.25
2.24
2.23
2.22
2.22
39.7
37.0
33.6
32.4
31.0
40.2
37.4
34.5
33.2
33.3
19.9
26.1
25.2
31.2
31.0
20.6
27.3
26.8
32.9
33.3
2.45
2.43
2.41
2.39
2.38
2.50
2.48
2.46
2.45
2.45
38.1
35.0
31.1
30.0
29.9
38.2
35.5
31.9
31.1
32.0
19.4
25.3
24.1
29.7
29.9
19.9
26.7
25.7
31.1
32.0
2.72
2.69
2.66
2.65
2.64
2.76
2.74
2.71
2.70
2.72
36.2
33.1
28.3
27.9
28.7
36.4
33.5
29.4
30.0
30.7
18.9
24.7
23.0
27.9
28.7
19.4
26.1
24.6
30.0
30.7
3.02
2.99
2.93
2.93
2.94
3.06
3.03
2.99
3.00
3.01
33.9
30.9
26.0
26.8
27.3
34.2
31.2
26.9
28.6
28.3
18.1
23.9
22.0
26.8
27.3
18.8
25.4
23.6
28.6
28.3
3.34
3.30
3.24
3.25
3.25
3.38
3.35
3.30
3.32
3.32
31.4
26.9
23.3
24.6
24.8
31.7
27.2
24.2
25.8
25.9
17.3
22.4
20.9
24.6
24.8
18.2
23.8
22.4
25.8
25.9
3.70
3.62
3.56
3.58
3.58
3.75
3.68
3.62
3.65
3.65
63†† 36.1
62
57
72
67
34.8
32.7
41.4
39.0
63†† 36.9
62
57
35.8
34.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CK5A/CK5BE
CK5A/CK5BT
042
036
042
036
036
042
042
036
042
036
0.99
0.91
CE3AA
036
0.97
0.94
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.92
0.92
0.92
0.92
0.92
0.91
0.92
0.92
0.92
042
042
042
042
036
042
042
036
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.93
0.94
0.94
0.94
0.94
0.94
0.94
0.94
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5A/CK5BW
CK5PA
CK5PE
CK5PT
CK5PT
CK5PW
CK5PW
COILS + 355MAV042060 VARIABLE SPEED FURNACE
CC5A/CD5AA
036
042
036
036
042
036
042
036
042
042
036
042
036
036
042
042
036
042
036
0.98
0.98
0.98
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.92
0.92
0.92
0.92
0.92
0.93
0.92
0.93
0.92
0.92
0.93
0.92
0.92
0.93
0.92
0.92
0.93
0.92
0.92
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
042
036
042
036
042
042
042
042
036
042
042
036
0.98
0.98
0.98
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
0.91
CC5A/CD5AW
CE3AA
CE3AA
CK3BA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5A/CK5BA
CK5A/CK5BE
CK5A/CK5BT
CK5PT
CK5PW
CK5A/CK5BW
CK5PA
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
042
036
042
036
042
042
042
042
036
042
042
036
0.98
0.98
0.98
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.90
0.90
0.90
0.91
0.90
0.90
0.90
0.90
0.90
0.91
0.91
0.91
CK5PE
CK5PT
CE3AA
CK5PW
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
036
042
036
042
036
042
036
042
036
042
0.98
0.98
0.98
0.97
0.97
0.99
0.99
0.99
0.99
0.99
0.94
0.93
0.94
0.93
0.94
0.94
0.94
0.94
0.94
0.94
CK5PT
CK5PW
CK3BA
COILS + 355MAV042040 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
042
036
042
0.98
0.98
0.97
0.93
0.93
0.92
CK5A/CK5BA
See notes on page 38.
—31—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A036-G Outdoor Section With CC5A/CD5AA042 Indoor Section continued
72
67
40.4
38.0
19.6
25.3
24.6
30.2
31.3
2.15
2.14
2.12
2.12
2.09
39.0
36.4
32.5
31.6
29.5
19.2
24.8
23.6
29.1
29.5
2.40
2.38
2.35
2.34
2.32
37.4
34.6
30.1
29.2
27.5
18.6
24.1
22.5
27.9
27.5
2.66
2.65
2.60
2.59
2.57
35.6
32.5
27.5
26.7
26.4
18.0
23.3
21.4
26.5
26.4
2.96
2.94
2.87
2.86
2.86
33.4
30.4
24.9
24.5
25.1
17.3
22.4
20.3
24.5
25.1
3.28
3.24
3.17
3.17
3.17
30.9
26.5
22.3
23.2
23.6
16.4
20.9
19.2
23.2
23.6
3.64
3.57
3.50
3.51
3.51
1050
1200
1350
63†† 34.9
62
57
33.9
31.3
72
67
41.0
38.5
20.3
26.5
26.3
32.4
32.7
20.9
27.8
27.8
34.5
34.8
2.20
2.19
2.18
2.17
2.15
2.25
2.24
2.23
2.22
2.22
39.7
37.0
33.6
32.4
31.0
40.2
37.4
34.5
33.2
33.3
19.9
26.1
25.2
31.2
31.0
20.6
27.3
26.8
32.9
33.3
2.45
2.43
2.41
2.39
2.38
2.50
2.48
2.46
2.45
2.45
38.1
35.0
31.1
30.0
29.9
38.2
35.5
31.9
31.1
32.0
19.4
25.3
24.1
29.7
29.9
19.9
26.7
25.7
31.1
32.0
2.72
2.69
2.66
2.65
2.64
2.76
2.74
2.71
2.70
2.72
36.2
33.1
28.3
27.9
28.7
36.4
33.5
29.4
30.0
30.7
18.9
24.7
23.0
27.9
28.7
19.4
26.1
24.6
30.0
30.7
3.02
2.99
2.93
2.93
2.94
3.06
3.03
2.99
3.00
3.01
33.9
30.9
26.0
26.8
27.3
34.2
31.2
26.9
28.6
28.3
18.1
23.9
22.0
26.8
27.3
18.8
25.4
23.6
28.6
28.3
3.34
3.30
3.24
3.25
3.25
3.38
3.35
3.30
3.32
3.32
31.4
26.9
23.3
24.6
24.8
31.7
27.2
24.2
25.8
25.9
17.3
22.4
20.9
24.6
24.8
18.2
23.8
22.4
25.8
25.9
3.70
3.62
3.56
3.58
3.58
3.75
3.68
3.62
3.65
3.65
63†† 36.1
62
57
72
67
34.8
32.7
41.4
39.0
63†† 36.9
62
57
35.8
34.8
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CK5A/CK5BE
CK5A/CK5BT
042
036
042
036
036
042
042
036
042
036
0.99
0.93
CC5A/CD5AW
036
0.98
0.92
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.94
0.94
0.94
0.94
0.94
0.93
0.94
0.94
0.94
042
036
042
036
042
036
042
042
036
042
036
036
042
042
036
042
036
0.97
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.91
0.92
0.92
0.93
0.92
0.93
0.92
0.92
0.93
0.92
0.92
0.93
0.92
0.92
0.93
0.92
0.92
CE3AA
CK5A/CK5BW
CK5PA
CK3BA
CK5PE
CK5PT
CK5A/CK5BA
CK5A/CK5BE
CK5A/CK5BT
CK5PW
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
036
042
036
042
036
042
036
042
036
042
042
036
042
036
036
042
042
036
042
036
0.98
0.98
0.98
0.97
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.93
0.92
0.92
0.92
0.93
0.92
0.93
0.93
0.93
0.93
0.92
0.93
0.93
0.93
0.93
0.93
0.92
0.93
0.93
0.93
CK5A/CK5BW
CK5PA
CK5PE
CK5PT
CK3BA
CK5PW
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CK5A/CK5BA
042
036
042
036
042
042
042
042
036
042
042
036
—
0.98
0.98
0.97
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
—
0.92
0.92
0.91
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
0.92
—
CK5A/CK5BE
CK5A/CK5BT
CE3AA
CK5A/CK5BW
CK5PA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5PE
CK5PT
CK5PT
CK5PW
CK5PW
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CC5A/CD5AA
036
0.98
0.92
042
0.98
0.92
See notes on page 38.
—32—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A042-F Outdoor Section With CD5AA048 Indoor Section
72
67
46.7
44.0
22.7
29.5
28.7
35.4
36.4
2.49
2.47
2.44
2.43
2.40
45.2
42.3
37.8
36.7
34.3
22.3
28.9
27.5
34.1
34.3
2.77
2.75
2.70
2.69
2.67
43.3
39.8
35.0
33.9
32.1
21.6
27.8
26.3
32.7
32.1
3.09
3.05
3.00
2.98
2.96
41.2
37.7
32.0
31.1
30.8
20.9
27.1
25.0
30.9
30.8
3.44
3.40
3.32
3.31
3.30
38.8
35.4
30.2
29.5
29.4
20.1
26.3
24.3
29.5
29.4
3.83
3.79
3.70
3.69
3.69
36.0
31.4
27.8
27.9
27.7
19.2
24.7
23.3
27.9
27.7
4.26
4.18
4.11
4.11
4.11
1225
1400
1575
63†† 40.5
62
57
39.3
36.4
72
67
47.1
44.3
23.3
30.5
30.7
37.9
38.1
23.9
31.9
32.0
40.2
40.7
2.55
2.52
2.51
2.50
2.48
2.61
2.58
2.57
2.57
2.56
45.8
42.7
39.3
37.8
36.2
46.2
43.0
40.5
38.9
39.0
23.0
30.2
29.5
36.5
36.2
23.7
31.5
31.4
38.5
39.0
2.83
2.81
2.78
2.76
2.74
2.90
2.86
2.85
2.83
2.83
43.9
40.5
36.4
35.0
35.0
44.4
41.1
37.6
36.5
37.6
22.5
29.4
28.3
34.8
35.0
23.2
31.1
30.1
36.5
37.6
3.15
3.12
3.07
3.06
3.05
3.22
3.18
3.15
3.13
3.15
41.8
38.4
33.6
32.7
33.6
41.8
38.8
35.0
35.4
35.8
21.8
28.8
27.1
32.7
33.6
22.4
30.3
29.1
35.4
35.8
3.51
3.47
3.40
3.39
3.40
3.56
3.53
3.48
3.49
3.49
39.3
35.9
31.8
31.2
32.2
39.5
36.3
33.1
32.7
33.5
21.1
27.9
26.3
31.2
32.2
21.8
29.6
28.3
32.7
33.5
3.90
3.85
3.79
3.78
3.79
3.95
3.92
3.87
3.86
3.87
36.5
31.7
27.9
29.5
29.3
36.8
32.0
27.9
30.7
30.7
20.2
26.4
24.7
29.5
29.3
21.1
28.0
26.0
30.7
30.7
4.33
4.25
4.18
4.21
4.20
4.40
4.32
4.24
4.29
4.29
63†† 42.1
62
57
72
67
40.5
38.1
47.5
44.9
63†† 42.5
62
57
41.6
40.7
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
CD5AA
042
048
048
048
042
048
048
042
048
042
048
042
042
048
048
042
048
042
042
048
048
042
048
006
003
005
048
006
003
005
006
003
005
042
048
1.00
1.01
CD5AA
048
1.00
0.94
0.99
1.00
1.00
1.01
1.01
1.00
1.00
1.00
1.00
1.00
0.98
1.00
1.00
1.00
1.00
1.00
0.98
1.00
1.00
1.00
1.00
1.01
1.02
0.98
1.01
0.99
1.02
0.98
1.01
1.02
0.98
1.01
0.99
1.00
1.01
1.00
1.00
1.01
1.00
1.00
1.00
1.00
1.00
1.00
0.97
1.00
1.00
1.00
1.00
1.00
0.97
1.00
1.00
1.00
1.00
0.99
0.89
0.92
0.91
0.99
0.89
0.91
0.91
0.89
0.92
0.91
1.00
1.00
CE3AA
CK3BA
042
048
042
048
042
048
042
042
048
042
048
042
042
048
1.00
1.01
1.00
1.00
0.99
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.95
0.95
0.95
0.94
0.93
0.94
0.94
0.95
0.94
0.95
0.94
0.94
0.95
0.94
CE3AA
CK5A/CK5BA
CF5AA
CK3BA
CK5A/CK5BE
CK5A/CK5BT
CK5A/CK5BA
CK5PA
CK5A/CK5BE
CK5A/CK5BT
CK5PE
CK5PT
CK5A/CK5BW
CK5PA
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
042
048
042
048
048
042
048
042
048
042
048
042
042
048
048
042
048
042
042
048
048
—
0.99
0.99
0.98
1.00
1.00
1.00
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
—
0.94
0.94
0.93
0.94
0.94
0.94
0.95
0.95
0.93
0.95
0.94
0.95
0.95
0.94
0.93
0.95
0.94
0.95
0.95
0.94
0.93
—
CK5PE
CK5PT
CK5PW
F(A,B)4(A,B)N(F,B,C)
CD5AA
CE3AA
FE4ANB
FE4ANF
CK3BA
CK5A/CK5BA
FG3AAA
FK4(C,D)NB
FK4(C,D)NF
CK5A/CK5BE
CK5A/CK5BT
FV4(A,B)NB
FV4(A,B)NF
CK5A/CK5BW
CK5PA
FX4(A,B)NF
CK5PE
CK5PT
COILS + 315(A,J)AV048090 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
042
048
0.99
0.99
0.94
0.94
CK5PW
See notes on page 38.
—33—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A042-F Outdoor Section With CD5AA048 Indoor Section Continued
72
67
46.7
44.0
22.7
29.5
28.7
35.4
36.4
2.49
2.47
2.44
2.43
2.40
45.2
42.3
37.8
36.7
34.3
22.3
28.9
27.5
34.1
34.3
2.77
2.75
2.70
2.69
2.67
43.3
39.8
35.0
33.9
32.1
21.6
27.8
26.3
32.7
32.1
3.09
3.05
3.00
2.98
2.96
41.2
37.7
32.0
31.1
30.8
20.9
27.1
25.0
30.9
30.8
3.44
3.40
3.32
3.31
3.30
38.8
35.4
30.2
29.5
29.4
20.1
26.3
24.3
29.5
29.4
3.83
3.79
3.70
3.69
3.69
36.0
31.4
27.8
27.9
27.7
19.2
24.7
23.3
27.9
27.7
4.26
4.18
4.11
4.11
4.11
1225
1400
1575
63†† 40.5
62
57
39.3
36.4
72
67
47.1
44.3
23.3
30.5
30.7
37.9
38.1
23.9
31.9
32.0
40.2
40.7
2.55
2.52
2.51
2.50
2.48
2.61
2.58
2.57
2.57
2.56
45.8
42.7
39.3
37.8
36.2
46.2
43.0
40.5
38.9
39.0
23.0
30.2
29.5
36.5
36.2
23.7
31.5
31.4
38.5
39.0
2.83
2.81
2.78
2.76
2.74
2.90
2.86
2.85
2.83
2.83
43.9
40.5
36.4
35.0
35.0
44.4
41.1
37.6
36.5
37.6
22.5
29.4
28.3
34.8
35.0
23.2
31.1
30.1
36.5
37.6
3.15
3.12
3.07
3.06
3.05
3.22
3.18
3.15
3.13
3.15
41.8
38.4
33.6
32.7
33.6
41.8
38.8
35.0
35.4
35.8
21.8
28.8
27.1
32.7
33.6
22.4
30.3
29.1
35.4
35.8
3.51
3.47
3.40
3.39
3.40
3.56
3.53
3.48
3.49
3.49
39.3
35.9
31.8
31.2
32.2
39.5
36.3
33.1
32.7
33.5
21.1
27.9
26.3
31.2
32.2
21.8
29.6
28.3
32.7
33.5
3.90
3.85
3.79
3.78
3.79
3.95
3.92
3.87
3.86
3.87
36.5
31.7
27.9
29.5
29.3
36.8
32.0
27.9
30.7
30.7
20.2
26.4
24.7
29.5
29.3
21.1
28.0
26.0
30.7
30.7
4.33
4.25
4.18
4.21
4.20
4.40
4.32
4.24
4.29
4.29
63†† 42.1
62
57
72
67
40.5
38.1
47.5
44.9
63†† 42.5
62
57
41.6
40.7
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CK5PA
042
1.00
0.93
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CC5A/CD5AA
042
048
042
048
048
042
048
042
048
042
048
042
048
048
042
048
042
048
048
1.00
0.99
0.99
1.00
1.00
1.00
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.94
0.93
0.94
0.93
0.93
0.93
0.94
0.94
0.93
0.94
0.93
0.94
0.93
0.93
0.94
0.93
0.94
0.93
0.93
048
042
048
048
1.00
1.00
1.00
1.00
0.92
0.93
0.92
0.92
CC5A/CD5AC
CC5A/CD5AW
CK5PT
CK5PW
CD5AA
CE3AA
COILS + 355MAV042040 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
CE3AA
042
048
042
048
1.00
1.00
0.99
0.99
1.02
1.00
1.00
0.99
CK3BA
CK5A/CK5BA
CK5A/CK5BT
COILS + 355MAV042060 VARIABLE SPEED FURNACE
CC5A/CD5AC
048
048
042
048
0.99
0.99
1.00
1.00
1.00
0.98
1.00
1.00
CD5AA
CE3AA
CK5A/CK5BW
CK5PA
COILS + 355MAV042080 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CD5AA
042
048
048
042
048
042
048
042
048
042
048
042
048
042
048
1.00
0.99
1.00
1.01
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.99
0.97
0.97
0.99
0.99
1.00
0.97
1.00
0.97
1.00
0.97
1.00
0.97
1.00
0.97
CK5PT
CK5PW
CE3AA
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
042
048
042
048
048
042
048
042
048
042
048
042
048
048
1.00
0.99
0.99
1.00
1.00
1.00
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.94
0.92
0.93
0.92
0.92
0.93
0.94
0.93
0.92
0.93
0.92
0.93
0.92
0.92
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5PA
CD5AA
CE3AA
CK3BA
CK5PT
CK5A/CK5BA
CK5A/CK5BT
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CD5AA
042
048
048
1.00
0.99
1.00
0.98
0.96
0.96
CK5A/CK5BW
See notes on page 38.
—34—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A042-F Outdoor Section With CD5AA048 Indoor Section Continued
72
67
46.7
44.0
22.7
29.5
28.7
35.4
36.4
2.49
2.47
2.44
2.43
2.40
45.2
42.3
37.8
36.7
34.3
22.3
28.9
27.5
34.1
34.3
2.77
2.75
2.70
2.69
2.67
43.3
39.8
35.0
33.9
32.1
21.6
27.8
26.3
32.7
32.1
3.09
3.05
3.00
2.98
2.96
41.2
37.7
32.0
31.1
30.8
20.9
27.1
25.0
30.9
30.8
3.44
3.40
3.32
3.31
3.30
38.8
35.4
30.2
29.5
29.4
20.1
26.3
24.3
29.5
29.4
3.83
3.79
3.70
3.69
3.69
36.0
31.4
27.8
27.9
27.7
19.2
24.7
23.3
27.9
27.7
4.26
4.18
4.11
4.11
4.11
1225
1400
1575
63†† 40.5
62
57
39.3
36.4
72
67
47.1
44.3
23.3
30.5
30.7
37.9
38.1
23.9
31.9
32.0
40.2
40.7
2.55
2.52
2.51
2.50
2.48
2.61
2.58
2.57
2.57
2.56
45.8
42.7
39.3
37.8
36.2
46.2
43.0
40.5
38.9
39.0
23.0
30.2
29.5
36.5
36.2
23.7
31.5
31.4
38.5
39.0
2.83
2.81
2.78
2.76
2.74
2.90
2.86
2.85
2.83
2.83
43.9
40.5
36.4
35.0
35.0
44.4
41.1
37.6
36.5
37.6
22.5
29.4
28.3
34.8
35.0
23.2
31.1
30.1
36.5
37.6
3.15
3.12
3.07
3.06
3.05
3.22
3.18
3.15
3.13
3.15
41.8
38.4
33.6
32.7
33.6
41.8
38.8
35.0
35.4
35.8
21.8
28.8
27.1
32.7
33.6
22.4
30.3
29.1
35.4
35.8
3.51
3.47
3.40
3.39
3.40
3.56
3.53
3.48
3.49
3.49
39.3
35.9
31.8
31.2
32.2
39.5
36.3
33.1
32.7
33.5
21.1
27.9
26.3
31.2
32.2
21.8
29.6
28.3
32.7
33.5
3.90
3.85
3.79
3.78
3.79
3.95
3.92
3.87
3.86
3.87
36.5
31.7
27.9
29.5
29.3
36.8
32.0
27.9
30.7
30.7
20.2
26.4
24.7
29.5
29.3
21.1
28.0
26.0
30.7
30.7
4.33
4.25
4.18
4.21
4.20
4.40
4.32
4.24
4.29
4.29
63†† 42.1
62
57
72
67
40.5
38.1
47.5
44.9
63†† 42.5
62
57
41.6
40.7
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Section
Indoor
Section
Size
Capacity
Power
Size
Capacity
Power
CE3AA
042
048
1.01
1.01
0.98
0.98
CK5PT
042
048
1.00
1.00
0.97
0.95
COILS + 355MAV060100 VARIABLE SPEED FURNACE
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CD5AA
042
048
048
042
048
042
048
042
048
042
048
042
048
1.00
0.99
1.00
1.01
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
0.98
0.96
0.96
0.98
0.98
0.97
0.95
0.97
0.95
0.97
0.95
0.97
0.95
CC5A/CD5AA
CC5A/CD5AW
CE3AA
042
048
042
048
042
048
042
042
048
042
042
048
—
1.00
1.00
1.01
1.01
1.00
1.00
1.00
1.00
1.00
1.00
1.00
1.00
—
0.98
0.96
0.98
0.98
0.97
0.95
0.97
0.97
0.95
0.97
0.97
0.95
—
CE3AA
CK3BA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5PA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5PA
CK5PT
CK5PW
See notes on page 38.
—35—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A048-F Outdoor Section With CC5A/CD5AA060 Indoor Section
72
67
53.0
50.3
25.6
33.2
32.8
40.4
42.3
2.87
2.85
2.84
2.83
2.81
51.3
48.0
45.0
44.0
40.1
25.0
32.2
31.8
39.3
40.1
3.18
3.16
3.14
3.14
3.12
49.4
45.8
42.8
41.5
38.0
24.3
31.4
30.9
38.1
38.0
3.53
3.51
3.49
3.48
3.46
47.2
43.5
40.5
38.9
36.7
23.6
30.5
29.9
36.8
36.7
3.93
3.89
3.88
3.86
3.85
44.8
41.0
38.1
36.1
35.2
22.8
29.6
28.8
35.3
35.2
4.36
4.32
4.30
4.28
4.28
42.1
38.4
33.9
33.2
33.6
21.9
28.6
27.0
33.2
33.6
4.83
4.80
4.76
4.75
4.75
1400
1600
1800
63†† 47.2
62
57
46.2
42.3
72
67
53.9
51.1
26.4
34.7
34.5
43.0
45.0
26.7
35.9
35.9
45.0
46.6
2.94
2.92
2.91
2.91
2.89
3.00
2.99
2.97
2.97
2.97
52.2
48.7
45.8
45.1
42.6
52.9
49.5
46.5
45.7
44.8
25.9
33.7
33.5
42.0
42.6
26.7
35.3
35.1
44.1
44.8
3.26
3.23
3.22
3.22
3.20
3.33
3.30
3.29
3.29
3.28
50.2
46.5
43.7
42.4
40.4
50.9
47.2
44.4
43.1
42.5
25.2
32.9
32.8
40.6
40.4
26.1
34.6
34.5
42.6
42.5
3.61
3.58
3.57
3.56
3.55
3.68
3.65
3.64
3.63
3.63
48.0
44.1
41.3
39.7
39.0
47.9
44.8
41.9
40.5
41.1
24.5
32.2
31.7
39.0
39.0
25.0
33.9
33.4
40.5
41.1
4.00
3.96
3.95
3.94
3.93
4.06
4.04
4.02
4.02
4.02
45.5
41.6
38.7
37.0
37.5
45.6
42.0
39.2
39.0
39.0
23.8
31.3
30.6
37.0
37.5
24.3
32.8
32.3
39.0
39.0
4.44
4.39
4.37
4.36
4.36
4.50
4.46
4.45
4.45
4.45
42.4
38.8
34.4
34.5
35.4
42.3
39.1
35.2
36.7
36.7
22.6
30.4
28.8
34.5
35.4
23.1
31.9
30.6
36.7
36.7
4.90
4.86
4.83
4.83
4.83
4.96
4.93
4.91
4.92
4.92
63†† 48.1
62
57
72
67
47.2
45.0
53.7
51.5
63†† 48.6
62
57
47.8
46.6
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Indoor
Section
Size
Capacity
1.00
0.97
0.99
1.01
0.99
1.02
1.00
1.01
0.99
0.99
1.00
0.99
1.00
0.99
1.00
0.99
1.01
0.99
1.00
0.99
1.00
0.99
1.01
0.99
1.01
1.02
1.02
1.01
0.99
1.00
1.02
1.01
1.02
1.01
1.01
0.99
Power
1.00
0.98
0.99
0.99
0.99
0.99
0.99
0.98
0.98
0.98
0.99
0.98
0.99
0.98
0.99
0.98
0.98
0.98
0.99
0.98
0.99
0.98
0.98
0.99
1.01
0.98
0.89
0.94
0.99
0.99
0.89
0.94
0.89
0.94
1.01
0.99
Section
CK3BA
Size
048
048
048
048
048
Capacity
0.99
0.99
0.99
0.99
Power
0.95
0.95
0.95
0.96
0.96
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
060
048
048
060
048
060
048
060
048
048
060
048
060
048
060
048
060
048
060
048
060
048
060
048
060
070
006
005
048
060
006
005
006
005
060
048
CK5A/CK5BA
CK5A/CK5BT
CK5PA
CD5AA
CD5PX
CE3AA
CK5PT
0.99
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
CD5AA
060
048
048
048
048
060
048
060
048
060
048
060
048
060
048
060
048
060
048
060
0.99
0.97
0.98
0.98
0.99
1.01
0.99
1.00
0.99
1.00
0.99
1.00
0.99
1.02
0.99
1.00
0.99
1.00
0.99
1.02
0.95
0.95
0.94
0.94
0.95
0.94
0.95
0.93
0.95
0.93
0.95
0.93
0.94
0.94
0.96
0.93
0.96
0.93
0.95
0.94
CF5AA
CK3BA
CE3AA
CK5A/CK5BA
CK5A/CK5BT
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5A/CK5BX
CK5PA
CK5A/CK5BW
CK5A/CK5BX
CK5PA
CK5PT
CK5PW
CK5PX
F(A,B)4(A,B)N(F,B,C)
CK5PT
CK5PW
CK5PX
FB4(A,B)NB
FE4ANB
FE4ANF
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
060
048
048
060
048
060
048
060
048
060
048
060
—
0.99
0.97
0.99
1.01
0.99
1.02
1.00
1.01
0.99
1.00
0.99
1.00
—
0.94
0.93
0.94
0.93
0.94
0.94
0.95
0.93
0.94
0.92
0.94
0.92
—
FG3AAA
FK4(C,D)NB
FK4(C,D)NF
FV4(A,B)NB
FV4(A,B)NF
FX4(A,B)NB
FX4(A,B)NF
CD5AA
CD5PX
CE3AA
CK3BA
COILS + 315(A,J)AV048090 VARIABLE SPEED FURNACE
CC5A/CD5AC
048
048
048
060
0.97
0.99
1.00
1.01
0.94
0.95
0.96
0.95
CK5A/CK5BA
CD5AA
CE3AA
See notes on page 38.
—36—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A048-F Outdoor Section With CC5A/CD5AA060 Indoor Section Continued
72
67
53.0
50.3
25.6
33.2
32.8
40.4
42.3
2.87
2.85
2.84
2.83
2.81
51.3
48.0
45.0
44.0
40.1
25.0
32.2
31.8
39.3
40.1
3.18
3.16
3.14
3.14
3.12
49.4
45.8
42.8
41.5
38.0
24.3
31.4
30.9
38.1
38.0
3.53
3.51
3.49
3.48
3.46
47.2
43.5
40.5
38.9
36.7
23.6
30.5
29.9
36.8
36.7
3.93
3.89
3.88
3.86
3.85
44.8
41.0
38.1
36.1
35.2
22.8
29.6
28.8
35.3
35.2
4.36
4.32
4.30
4.28
4.28
42.1
38.4
33.9
33.2
33.6
21.9
28.6
27.0
33.2
33.6
4.83
4.80
4.76
4.75
4.75
1400
1600
1800
63†† 47.2
62
57
46.2
42.3
72
67
53.9
51.1
26.4
34.7
34.5
43.0
45.0
26.7
35.9
35.9
45.0
46.6
2.94
2.92
2.91
2.91
2.89
3.00
2.99
2.97
2.97
2.97
52.2
48.7
45.8
45.1
42.6
52.9
49.5
46.5
45.7
44.8
25.9
33.7
33.5
42.0
42.6
26.7
35.3
35.1
44.1
44.8
3.26
3.23
3.22
3.22
3.20
3.33
3.30
3.29
3.29
3.28
50.2
46.5
43.7
42.4
40.4
50.9
47.2
44.4
43.1
42.5
25.2
32.9
32.8
40.6
40.4
26.1
34.6
34.5
42.6
42.5
3.61
3.58
3.57
3.56
3.55
3.68
3.65
3.64
3.63
3.63
48.0
44.1
41.3
39.7
39.0
47.9
44.8
41.9
40.5
41.1
24.5
32.2
31.7
39.0
39.0
25.0
33.9
33.4
40.5
41.1
4.00
3.96
3.95
3.94
3.93
4.06
4.04
4.02
4.02
4.02
45.5
41.6
38.7
37.0
37.5
45.6
42.0
39.2
39.0
39.0
23.8
31.3
30.6
37.0
37.5
24.3
32.8
32.3
39.0
39.0
4.44
4.39
4.37
4.36
4.36
4.50
4.46
4.45
4.45
4.45
42.4
38.8
34.4
34.5
35.4
42.3
39.1
35.2
36.7
36.7
22.6
30.4
28.8
34.5
35.4
23.1
31.9
30.6
36.7
36.7
4.90
4.86
4.83
4.83
4.83
4.96
4.93
4.91
4.92
4.92
63†† 48.1
62
57
72
67
47.2
45.0
53.7
51.5
63†† 48.6
62
57
47.8
46.6
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Indoor
Section
Size
Capacity
0.99
1.00
0.99
1.02
0.99
1.00
0.99
1.00
Power
0.94
0.92
0.94
0.93
0.94
0.92
0.94
0.92
0.94
0.92
Section
CC5A/CD5AC
CC5A/CD5AW
CD5AA
Size
048
060
048
048
060
Capacity
0.97
1.01
0.99
1.00
Power
0.99
0.97
0.99
1.00
0.97
CK5A/CK5BT
048
060
048
060
048
060
048
060
048
060
CK5A/CK5BW
CK5A/CK5BX
CK5PA
CE3AA
1.01
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CK5PT
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
CD5AA
060
048
060
048
048
060
060
060
060
060
060
060
060
1.00
0.97
1.01
0.99
1.00
1.01
1.00
1.00
1.00
1.02
1.00
1.00
1.02
1.00
0.99
0.97
0.99
1.00
0.97
0.98
0.98
0.98
0.97
0.98
0.98
0.97
CK5PW
CK5PX
0.99
1.02
CE3AA
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AC
CC5A/CD5AW
060
048
048
060
048
060
048
060
048
060
048
060
048
060
048
060
048
060
048
060
048
060
0.99
0.97
0.99
1.01
0.99
1.02
1.00
1.01
0.99
1.00
0.99
1.00
0.99
1.00
0.99
1.02
0.99
1.00
0.99
1.00
0.99
1.02
0.93
0.92
0.93
0.93
0.93
0.93
0.94
0.93
0.93
0.92
0.93
0.92
0.93
0.92
0.93
0.92
0.94
0.92
0.94
0.92
0.94
0.92
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CD5AA
CD5PX
CE3AA
CK5PT
CK5PX
CK3BA
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CC5A/CD5AA
CC5A/CD5AW
060
048
060
048
060
048
060
060
060
048
060
060
060
048
060
1.00
0.99
1.01
1.00
1.01
0.99
1.00
1.00
1.00
0.99
1.02
1.00
1.00
0.99
1.02
1.00
0.99
0.97
1.00
0.97
0.98
0.97
0.97
0.97
0.98
0.97
0.97
0.97
0.98
0.97
CK5A/CK5BA
CK5A/CK5BT
CE3AA
CK3BA
CK5A/CK5BW
CK5A/CK5BX
CK5PA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BW
CK5A/CK5BX
CK5PA
CK5PT
CK5PW
CK5PX
CK5PT
CK5PW
CK5PX
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CC5A/CD5AA
060
1.00
1.00
See notes on page 38.
—37—
DETAILED COOLING CAPACITIES* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
EVAP
AIR
75
Capacity
MBtuh†
85
Capacity
MBtuh†
95
Capacity
MBtuh†
105
Capacity
MBtuh†
115
Capacity
MBtuh†
125
Capacity
MBtuh†
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
Total
Sys
CFM EWB Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW** Total Sens‡ kW**
550A060-H Outdoor Section With CD5PX060 Indoor Section
57
62
67
72
57.89 57.89 4.31 55.67 55.67 4.76 53.35 53.35 5.27 50.80 50.80 5.83 47.87 47.87 6.43 44.52 44.52 7.08
59.84 53.84 4.33 57.09 52.53 4.78 54.23 51.17 5.28 51.12 49.67 5.84 47.85 47.85 6.43 44.51 44.51 7.08
65.37 45.55 4.39 62.27 44.22 4.84 59.00 42.86 5.34 55.44 41.38 5.89 51.48 39.77 6.47 47.02 37.98 7.11
71.38 37.24 4.45 67.95 35.91 4.91 64.32 34.50 5.41 60.36 33.01 5.96 55.94 31.39 6.53 50.98 29.58 7.15
1750
2000
2250
57
62
67
72
57
62
67
72
60.22 60.22 4.42 57.88 57.88 4.89 55.28 55.28 5.39 52.49 52.49 5.95 49.40 49.40 6.55 45.73 45.73 7.19
61.19 57.67 4.44 58.34 56.29 4.89 55.34 54.77 5.39 52.48 52.48 5.95 49.40 49.40 6.55 45.71 45.71 7.19
66.60 48.31 4.49 63.37 46.97 4.96 59.86 45.53 5.45 56.10 44.02 5.99 52.03 42.39 6.58 47.43 40.59 7.21
72.67 38.92 4.56 69.11 37.58 5.02 65.22 36.14 5.52 61.05 34.63 6.06 56.50 32.98 6.63 51.36 31.14 7.25
62.16 62.16 4.54 59.57 59.57 5.00 56.86 56.86 5.50 53.93 53.93 6.06 50.56 50.56 6.65 46.69 46.69 7.29
62.34 61.20 4.54 59.51 59.51 5.00 56.85 56.85 5.50 53.92 53.92 6.06 50.55 50.55 6.65 46.69 46.69 7.29
67.52 50.93 4.60 64.07 49.53 5.06 60.43 48.08 5.55 56.59 46.55 6.09 52.42 44.91 6.67 47.72 43.08 7.31
73.65 40.55 4.67 69.86 39.16 5.13 65.83 37.69 5.62 61.56 36.15 6.16 56.87 34.48 6.73 51.61 32.64 7.35
Multipliers for Determining the Performance With Other Indoor Sections
Cooling
Cooling
Indoor
Indoor
Section
Size
060
060
060
060
060
060
060
060
060
060
060
060
070
060
070
006
060
006
006
060
Capacity
0.95
0.98
1.00
0.98
0.98
0.98
0.98
1.00
0.98
0.98
1.00
0.98
1.00
0.98
1.00
1.00
0.97
1.00
1.00
1.00
Power
0.98
1.00
1.00
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
1.01
1.00
1.01
1.00
0.94
0.99
0.94
0.94
1.00
Section
Size
060
060
060
060
060
Capacity
0.97
0.99
0.97
0.97
Power
0.96
0.96
0.96
0.96
0.96
CC5A/CD5AA
CC5A/CD5AW
CD5PX
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
F(A,B)4BN(F,B,C)
FB4BNB
FC4CN(F,B)
FC4CNB
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
0.99
COILS + 315(A,J)AV066155 VARIABLE SPEED FURNACE
CC5A/CD5AA
CD5PX
060
060
060
060
060
060
060
060
060
060
0.95
0.98
0.98
0.97
0.97
0.97
0.99
0.97
0.97
0.99
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
0.95
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK5PT
CK5PX
FE4ANB
FG3AAA
FK4DNB
FV4BNB
COILS + 355MAV060080 VARIABLE SPEED FURNACE
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5PA
060
060
060
060
060
0.97
0.97
0.97
0.97
0.97
1.01
1.01
1.01
1.01
1.01
FX4BNB
COILS + 315(A,J)AV060110 VARIABLE SPEED FURNACE
CC5A/CD5AA
CD5PX
060
060
060
060
060
060
060
060
060
060
0.95
0.98
0.98
0.97
0.97
0.97
0.99
0.97
0.97
0.99
0.98
0.98
0.98
0.97
0.97
0.97
0.97
0.97
0.97
0.97
CK5PT
COILS + 355MAV060100 VARIABLE SPEED FURNACE
CE3AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5PA
060
060
060
060
060
0.97
0.97
0.97
0.97
0.97
1.00
0.99
0.99
0.99
0.99
CK5PT
COILS + 355MAV060120 VARIABLE SPEED FURNACE
CK5PT
CK5PX
CC5A/CD5AA
CK3BA
CK5A/CK5BA
CK5A/CK5BT
CK5A/CK5BX
CK5PA
060
060
060
060
060
060
060
060
0.95
0.97
0.97
0.97
0.99
0.97
0.97
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
0.99
COILS + 315(A,J)AV066135 VARIABLE SPEED FURNACE
CC5A/CD5AA
CD5PX
CE3AA
CK3BA
CK5A/CK5BA
060
060
060
060
060
0.95
0.98
0.98
0.97
0.97
0.96
0.96
0.96
0.96
0.96
CK5PT
CK5PX
NOTE: When the required data falls between the published data, interpolation may be performed. Extrapolation is not an acceptable practice.
* Detailed cooling capacities are based on indoor and outdoor unit at the same elevation per ARI standard 210/240-94. If additional tubing length and/or
indoor unit is located above outdoor unit, a slight variation in capacity may occur.
† Total and sensible capacities are net capacities. Blower motor heat has been subtracted.
‡ Sensible capacities shown are based on 80°F (27°C) entering air at the indoor coil. For sensible capacities at other than 80°F (27°C), deduct 835 Btuh
(245 kW) per 1000 CFM (480 L/S) of indoor coil air for each degree below 80°F (27°C), or add 835 Btuh (245 kW) per 1000 CFM (480 L/S) of indoor coil air
per degree above 80°F (27°C). When the required data falls between the published data, interpolation may be performed.
** Total system kW is total of indoor and outdoor unit kilowatts.
†† At TVA rating indoor condition (75°F edb/63°F ewb). All other indoor air temperatures are at 80°F edb.
—38—
CONDENSER ONLY RATINGS*
CONDENSER ENTERING AIR TEMPERATURES °F
SST
°F
55
65
75
85
95
105
115
125
550A024-G
17.9
88.3
1.24
TCG
SDT
KW
20.9
69.8
0.92
19.4
79.1
1.07
16.2
97.6
1.41
14.4
106.7
1.60
12.4
115.7
1.78
10.2
124.7
1.97
7.8
133.6
2.16
30
35
40
45
50
55
TCG
SDT
KW
24.2
71.3
0.93
21.7
80.6
1.10
20.1
89.8
1.26
18.4
99.1
1.45
16.6
108.2
1.64
14.6
117.3
1.84
12.4
126.2
2.04
10.0
135.1
2.25
TCG
SDT
KW
28.7
72.6
0.94
25.0
82.0
1.11
22.5
91.4
1.30
20.8
100.6
1.48
19.0
109.8
1.68
16.9
118.9
1.89
14.7
127.9
2.11
12.3
136.7
2.33
TCG
SDT
KW
37.2
73.5
0.94
29.3
83.4
1.12
25.9
92.7
1.31
23.4
101.9
1.52
21.4
111.3
1.73
19.4
120.4
1.95
17.2
129.5
2.18
14.8
138.3
2.41
TCG
SDT
KW
44.0
74.4
0.94
35.9
84.6
1.13
30.2
94.0
1.32
27.0
103.2
1.53
24.3
112.4
1.76
22.1
121.6
2.00
19.9
130.6
2.24
17.5
139.5
2.48
TCG
SDT
KW
51.6
75.2
0.90
45.6
85.1
1.12
35.8
95.3
1.33
31.2
104.6
1.55
27.9
113.7
1.78
25.3
122.8
2.03
22.8
131.8
2.30
20.4
140.7
2.58
550A030-F
26.6
95.3
1.82
TCG
SDT
KW
29.9
75.3
1.42
28.2
85.3
1.61
25.0
105.0
2.07
23.4
115.0
2.34
21.8
125.0
2.64
20.2
135.0
2.98
18.4
145.0
3.36
30
35
40
45
50
55
TCG
SDT
KW
32.9
75.9
1.42
31.1
85.8
1.61
29.4
95.7
1.82
27.7
106.0
2.06
25.9
116.0
2.33
24.1
126.0
2.63
22.3
135.0
2.96
20.4
146.0
3.34
TCG
SDT
KW
36.1
76.7
1.42
34.2
86.5
1.61
32.3
96.3
1.82
30.5
106.0
2.06
28.6
116.0
2.32
26.6
126.0
2.62
24.6
136.0
2.96
22.5
146.0
3.33
TCG
SDT
KW
39.5
77.8
1.43
37.5
87.5
1.61
35.4
97.2
1.82
33.4
107.0
2.06
31.3
117.0
2.33
29.2
127.0
2.62
27.1
137.0
2.96
24.7
147.0
3.33
TCG
SDT
KW
43.1
79.2
1.44
40.9
88.8
1.63
38.7
98.4
1.83
36.5
108.0
2.07
34.3
118.0
2.33
32.0
128.0
2.63
29.6
138.0
2.96
27.1
147.0
3.33
TCG
SDT
KW
46.9
80.8
1.46
44.5
90.2
1.64
42.2
99.8
1.85
39.8
109.0
2.08
37.4
119.0
2.35
34.9
129.0
2.64
32.3
139.0
2.98
29.6
148.0
3.34
550A036-F, G
TCG
SDT
KW
36.3
72.2
1.67
34.4
81.8
1.90
32.4
91.3
2.16
30.4
28.2
110.0
2.74
26.0
120.0
3.06
23.7
129.0
3.39
21.1
139.0
3.73
30
35
40
45
50
101.0
2.44
TCG
SDT
KW
39.8
73.5
1.68
37.8
83.1
1.91
35.6
92.7
2.17
33.5
102.0
2.45
31.2
112.0
2.75
28.8
121.0
3.08
26.3
130.0
3.43
23.6
140.0
3.78
TCG
SDT
KW
43.5
75.0
1.68
41.3
84.5
1.91
39.0
94.0
2.17
36.7
104.0
2.46
34.3
113.0
2.77
31.8
122.0
3.10
29.1
132.0
3.46
26.2
141.0
3.83
TCG
SDT
KW
47.4
76.6
1.68
45.1
86.0
1.92
42.7
95.4
2.18
40.1
105.0
2.47
37.6
114.0
2.79
34.8
124.0
3.13
32.0
133.0
3.49
28.9
142.0
3.87
TCG
SDT
KW
51.5
78.3
1.69
49.1
87.6
1.93
46.5
97.0
2.19
43.8
106.0
2.48
41.0
116.0
2.80
38.1
125.0
3.15
35.0
134.0
3.52
31.7
143.0
3.91
TCG
SDT
KW
55.9
80.1
1.70
53.2
89.3
1.93
50.5
98.6
2.20
47.6
108.0
2.50
44.6
117.0
2.82
41.5
126.0
3.17
38.2
135.0
3.54
34.6
144.0
3.94
55
See notes on page 40.
—39—
CONDENSER ONLY RATINGS* Continued
CONDENSER ENTERING AIR TEMPERATURES °F
SST
°F
55
65
75
85
95
105
115
125
550A042-F
37.0
91.8
2.39
TCG
SDT
KW
41.4
72.3
1.85
39.2
82.0
2.10
34.8
102.0
2.72
32.5
111.0
3.07
30.2
121.0
3.46
27.8
130.0
3.89
25.3
140.0
4.36
30
35
40
45
50
55
TCG
SDT
KW
45.4
73.7
1.86
43.0
83.4
2.12
40.6
93.1
2.41
38.2
103.0
2.74
35.7
112.0
3.09
33.2
122.0
3.49
30.6
131.0
3.92
27.8
141.0
4.39
TCG
SDT
KW
49.6
75.2
1.88
47.0
84.8
2.14
44.5
94.4
2.43
41.8
104.0
2.76
39.1
114.0
3.12
36.4
123.0
3.51
33.5
133.0
3.94
30.5
142.0
4.41
TCG
SDT
KW
54.0
76.7
1.89
51.3
86.3
2.16
48.5
95.9
2.45
45.7
106.0
2.78
42.7
115.0
3.14
39.8
125.0
3.54
36.7
134.0
3.97
33.3
143.0
4.44
TCG
SDT
KW
58.8
78.4
1.92
55.8
87.9
2.18
52.8
97.4
2.47
49.7
107.0
2.80
46.6
117.0
3.17
43.3
126.0
3.57
39.9
135.0
4.00
36.3
144.0
4.47
TCG
SDT
KW
63.8
80.2
1.94
60.6
89.6
2.20
57.4
99.1
2.50
54.0
109.0
2.83
50.6
118.0
3.20
47.1
127.0
3.60
43.4
137.0
4.03
39.5
145.0
4.50
550A048-F
40.9
92.0
2.73
TCG
SDT
KW
45.8
72.0
2.11
43.3
82.0
2.40
38.5
102.0
3.09
36.0
112.0
3.52
33.6
122.0
3.98
31.0
132.0
4.51
28.4
142.0
5.09
30
35
40
45
50
55
TCG
SDT
KW
50.6
72.0
2.10
47.9
82.0
2.39
45.2
92.0
2.71
42.6
102.0
3.08
39.9
112.0
3.49
37.2
122.0
3.96
34.4
132.0
4.48
31.5
142.0
5.06
TCG
SDT
KW
55.7
72.3
2.10
52.8
82.1
2.38
49.9
92.0
2.70
47.0
102.0
3.06
44.1
112.0
3.47
41.1
122.0
3.93
38.1
132.0
4.45
34.9
142.0
5.02
TCG
SDT
KW
60.9
73.6
2.13
57.8
83.2
2.40
54.7
92.7
2.71
51.7
102.0
3.06
48.6
112.0
3.46
45.4
122.0
3.91
42.1
132.0
4.42
38.5
142.0
4.99
TCG
SDT
KW
66.3
75.1
2.17
63.0
84.6
2.44
59.7
94.1
2.75
56.4
104.0
3.09
53.1
113.0
3.48
49.8
123.0
3.92
46.2
132.0
4.41
42.5
142.0
4.96
TCG
SDT
KW
72.1
76.7
2.21
68.5
86.1
2.48
65.0
95.6
2.79
61.4
105.0
3.14
57.8
114.0
3.52
54.2
124.0
3.95
50.5
133.0
4.43
46.5
143.0
4.96
550A060-H
51.6
94.3
11.22
56.8
95.9
11.38
62.2
97.5
11.56
67.9
99.4
11.76
73.9
101.2
11.97
80.0
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
TCG
SDT
KW
57.7
75.9
8.82
63.5
77.7
8.98
69.6
79.6
9.16
76.1
81.6
9.36
82.8
83.7
9.57
89.8
85.9
9.80
54.6
85.1
9.97
60.1
86.8
10.12
65.9
88.5
10.29
72.0
90.5
10.48
78.4
92.5
10.68
85.0
94.5
10.9
48.5
103.4
12.59
53.3
104.9
12.76
58.4
106.5
12.94
63.8
108.2
13.13
69.3
45.4
112.5
14.12
49.9
114.0
14.28
54.6
115.4
14.44
59.5
117.0
14.63
64.5
42.1
121.6
15.83
46.3
122.9
15.98
50.6
124.3
16.15
55.0
125.7
16.32
59.6
38.6
130.6
17.63
42.4
131.8
17.79
46.3
133.0
17.95
50.3
134.3
18.11
54.3
34.6
139.4
19.46
38.1
140.5
19.72
41.6
141.6
19.9
45.10
142.7
20.05
48.6
30
35
40
45
50
55
110.0
13.36
75.0
111.8
13.58
118.6
14.84
69.7
120.3
15.07
127.2
16.5
64.3
128.7
16.71
135.6
18.28
58.5
136.9
18.45
143.8
20.19
52.3
144.9
20.34
103.2
12.19
* ARI listing applies only to systems shown in Combination Ratings table.
KW — Outdoor Unit Kilowatts Only
SDT — Saturated Temperature Leaving Compressor (°F)
SST — Saturated Temperature Entering Compressor (°F)
TCG — Gross Cooling Capacity (1000 Btuh).
—40—
SYSTEM DESIGN SUMMARY
1. Intended for outdoor installation with free air inlet and outlet. Outdoor fan external static pressure available is less than 0.01-in. wc.
2. Minimum outdoor operating air temperature without low-ambient operation accessory is 55°F (12.8°C).
3. Maximum outdoor operating air temperature is 125°F (51.7°C).
4. For reliable operation, unit should be level in all horizontal planes.
5. Maximum elevation of indoor coil above or below base of outdoor unit is: Indoor coil above = 50 ft, indoor coil below = 150 ft.
6. For interconnecting refrigerant tube lengths greater than 50 ft and/or 20 ft vertical differential, consult the Residential Split-System Application
Guideline and Service Manual for
Air Conditioners and Heat Pumps using Puron® (R-410A) Refrigerant available from equipment distributor.
7. If any refrigerant tubing is buried, provide a 6 in. vertical rise to the valve connections at the unit. Refrigerant tubing lengths up to 36 in. may be
buried without further consideration. Do not bury refrigerant lines longer than 3 ft.
8. Use only copper wire for electric connection at unit. Aluminum and clad aluminum are not acceptable for the type of connector provided.
9. Mismatches of indoor coil capacity more than one size larger than outdoor unit capacity may result in inadequate indoor comfort.
10. Do not apply capillary tube indoor coils to these units.
11. Factory-supplied filter drier must be installed.
—41—
—42—
—43—
Air-Cooled, Split-System
Air Conditioner
550A
GUIDE SPECIFICATIONS
2 to 5 Tons Nominal
Fan blades will be statically and dynamically balanced.
GENERAL
Condenser fan openings will be equipped with PVC-coated
steel wire safety guards.
System Description
Outdoor-mounted, air-cooled, split-system air conditioner unit
suitable for ground or rooftop installation. Unit consists of a her-
metic compressor, an air-cooled coil, propeller-type condenser
fan, and a control box. Unit will discharge supply air upward as
shown on contract drawings. Unit will be used in a refrigeration
circuit to match up to a packaged fan coil or coil unit.
Quality Assurance
Unit will be rated in accordance with the latest standard of ARI
Standard 210.
Unit will be certified for capacity and efficiency, and listed in the
lastest ARI directory.
Unit construction will comply with latest edition of ANSI/
ASHRAE and with NEC.
Unit will be constructed in accordance with UL standards and
will carry the UL label of approval. Unit will have c-UL approval.
Unit cabinet will be capable of withstanding Federal Test Method
Standard No. 141 (Method 6061) 500-hr salt spray test.
Compressor
Compressor will be hermetically sealed.
Compressor will be mounted on rubber vibration isolators.
Condenser Coil
Condenser coil will be air cooled.
Coil will be constructed of aluminum fins mechanically bonded
to copper tubes which are then cleaned, dehydrated, and
sealed.
Refrigeration Components
Refrigeration circuit components will include liquid-line shutoff
valve with sweat connections, vapor-line shutoff valve with
sweat connections, system charge of refrigerant Puron® (R-
410A), and compressor oil.
Unit will be equipped with a high-pressure switch, low-pressure
switch and filter drier for Puron refrigerant.
Operating Characteristics
Air-cooled condenser coils will be leak tested at 250 psig and
pressure tested at 450 psig.
Unit constructed in ISO9001 approved facility.
Delivery, Storage, and Handling
Unit will be shipped as single package only and is stored and
handled per unit manufacturer’s recommendations.
The capacity of the unit will meet or exceed _____ Btuh at a
suction temperature of _____ °F.The power consumption at full
load will not exceed _____ kW.
Combination of the unit and the evaporator or fan coil unit will
have a total net cooling capacity of _____ Btuh or greater at
conditions of _____ CFM entering air temperature at the
evapo-rator at _____ °F wet bulb and _____ °F dry bulb, and
air enter-ing the unit at _____ °F.
Warranty (for inclusion by specifying engineer)
U.S. and Canada only.
The system will have a SEER of _____ Btuh/watt or greater at
DOE conditions.
PRODUCTS
Equipment
Factory assembled, single piece, air-cooled air conditioner unit.
Contained within the unit enclosure is all factory wiring, piping,
controls, compressor, refrigerant charge Puron® (R-410A), and
special features required prior to field start-up.
Electrical Requirements
Nominal unit electrical characteristics will be _____ v, single
phase, 60 hz.The unit will be capable of satisfactory opera-tion
within voltage limits of _____ v to _____ v.
Unit electrical power will be single point connection.
Control circuit will be 24v.
Unit Cabinet
Unit cabinet will be constructed of galvanized steel, bonderized,
and coated with a powder coat paint.
Special Features
Fans
Refer to section of this literature identifying accessories and
descriptions for specific features and available enhancements.
Condenser fan will be direct-drive propeller type, discharging air
upward.
Condenser fan motors will be totally enclosed, 1-phase type
with class B insulation and permanently lubricated bearings.
Shafts will be corrosion resistant.
SPECIFICATIONS SUBJECT TO CHANGE WITHOUT NOTICE
UNIT MUST BE INSTALLED IN ACCORDANCE
WITH INSTALLATION INSTRUCTIONS
Cancels: PDS 550A.24.9
© 2004 Bryant Heating & Cooling Systems, 7310 W. Morris St. Indpls, IN 46231
—44—
PRINTED IN U.S.A.
Catalog No. 5255-007
12-04
|