Portable Air Conditioner
Instruction Manual
YPL3-10C
Please read the instructions completely before using this product
This product is designed for household use only.
2011.02.21
受控
FOR SERVICE : CALL TRANS GLOBAL SERVICE 1-800-360-2742
INTRODUCTION
Thank you for choosing Our Portable Air Conditioner. Please read this manual carefully before using this
product.
The following tips may help to maximize the efficiency of your air conditioner:
•
•
•
When the air conditioner is on, keep doors and windows closed.
Turn off kitchen or bathroom exhaust fans when your air conditioner is on.
Operate the unit in recommended room size.
300 sq.ft.(28sq.m) for 10,000 BTU
•
•
•
Turn off the air conditioner when you leave home.
Check the filter monthly and keep it clearn.
Do not place anything that may generate heat near the thermostat or the air conditioner may run
longer then necessary.
•
•
Keep blinds and curtains closed during hot weather.
Avoid blocking the air vents.
SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE
3
IMPORTANT SAFEGUARDS
When using electrical appliances, basic safety precautions should always be followed:
1. Read all instructions
2. To protect against fire, electric shock and personal injury, do not immerse cord, plugs, or the unit in
water or other liquid.
3. Close supervision is necessary when the product is used around the chirldren. This product is not
intended for use by chirdren.
4. Do not operate the product with a damaged cord/plug. If the plug is damged in any manner, please
return the product for repair.
5. Always keep the product in an upright position.
6. During the transit, the product could be placed up side down, which may cause the oil in the
compressor drain into the refrigerant tubes reducing the cooling efficiency. Thus, before using the
product, keep the product in a upright position for 1~2 hours.
7. Connect the product to a properly grounded power supply. Do not use an adapter plug or extension
cord.
8. Do not cover or insert any object into the air inlet and/or outlet.
9. Turn off the power when no one is in the room.
10. Do not place anything in the direct path of the airflow.
11. Do not place the product near any heat source or where gas leakage may occur.
12. Do not use the product near a bath, shower, or swimming pool, or in any wet enviorment.
13. Do not turn off/on the product by plugging or unplugging the power cord directly.
14. Do not modify the power cord or share the outlet with other appliances.
15. Unplug the product from the outlet when not in use and before cleaning.
16. Do not use attachments not recommended by the manufacturer as they may cause injuries.
17. Do not expose skin, face and eyes directly to cool air for a long period of time.
18. If an abnormal odor or smoke comes from the product, disconnect the unit immediately and bring to
a qualified service technician.
19. Unplug the power from wall outlet before cleaning the filter and do not touch the metal parts inside.
20. Do not apply any kind of insecticide or flammable spray onto or into the unit.
21. Do not step on the product or place objects on the unit.
22. Place the product on a steady and flat surface, or the water may leak out of the water tank.
23. Before storing the product, always drain the water from the unit and clean the filter.
24. Do not use the product for other than it’s intended use.
The manufacturer disclaims any responsibility if the above instructions are not followed.
The manufacturer reserves the right to make technical changes without notice.
SAVE THESE INSTRUCTIONS
This product is designed for household use only
4
LCDI POWER CORD AND PLUG
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord and
plug. The LCDI power cord and plug will shut off the supply source via electrical disconnect (circuit trip) if the
nominal current leakage between the cord shield and either load conductor exceeds a predetermined value.
The cord will not be able to conduct power until the devise has been manually reset. This device provides
protection to reduce the risk of fire due to arcing faults in the power cord. The cord shields are not grounded
and they must be considered as shock hazards if exposed. The cord shield must not be connected to
ground or to any exposed metal.
To ensure if the plug is working properly, please follow the following instructions to test it:
1. Plug power cord into wall outlet.
2. Press TEST button. The circuit should trip, cutting power to the air conditioner.
3. Press RESET button for use.
DO NOT USE IF ABOVE TEST FAILS.
In the event the LCDI Plug of the power cord trips by itself, then first examine the
cord for any damage. If there is no damage to the cord, then press the RESET
Button. If the LCDI Plug trips again, then immediately unplug the power supply
cord and contact a professional technician or service center.
WARNING:
1. Do not use the TEST and RESET buttons as “ON” and “OFF” switches.
2. Do not press the TEST button while the air conditioner is operating
3. The cord and plug are designed for indoor use only.
4. Periodically examine the cord for any damage. If the shield gets exposed, immediately unplug the
power cord and do not use the unit.
5
SAFETY
PLEASE READ ALL THESE INSTRUCTIONS CAREFULLY BEFORE USING THIS APPLIANCE
Only use this appliance for domestic purposes and in the way indicated in these
instructions. Never use for any other purposes.
Do not use the appliance outside and always place it in a dry environment.
From time to time, check the cord. Never use the cord, the plug or the appliance when
they show any sign of damage. The cord length of this product has been selected to
reduce the possibility of being injured. Do not use your appliance with an extension
cord unless it has been checked and tested by a qualified electrician or electrical
supplier.
Keep the appliance away from hot sources and direct sunlight.
Always switch off the appliance before unplugging it.
Unplug the appliance before cleaning or changing any parts of the appliance or when
it’s not in use.
Clean the appliance according to manual.
Make sure that the voltage rating on the type plate corresponds to your main voltage.
Any error in connecting the appliance invalidates the guarantee.
Never leave the appliance unsupervised when in use. Switch off the appliance if you
have to go away for even a short time.
Never pull the cord to unplug or move the appliance.
Never immerse the appliance in water or any other liquid for any reason.
Keep the appliance away from water or oil splashes.
Respect the instructions for cleaning.
Do not insert sharp metallic objects or fingers in the air swinging fins of the appliance.
Never repair the appliance yourself. All interventions made by a non-qualified person
can be dangerous. As well any changing of the cord must be done by a qualified
electrician.
Never use accessories non-delivered by the supplier. This could be dangerous and
could damage the appliance.
Special recommendations:
Install the portable air conditioner on a flat location with a large space, without obstacles.
Leave a 50cm minimum space between the unit and the wall.
The plug shall be always accessible after its installation.
Always place the appliance in a vertical position, in order to maintain the compressor in
good working condition.
Do not use the appliance near gas or other inflammable liquids.
Do not block the air outlet and inlet ventilation.
Do not use spray (insecticides, painting) or any other inflammable products near the
appliance as the plastic case may be deformed. The unit may sustain electrical damage.
Power sources
The plug has to be well fixed and should not be damaged.
Do not plug in the appliance with an adaptor.
6
Plug into the wall socket before switching on the appliance then press on the ON/OFF
button.
THE MANUFACTURER WILL NOT ASSUME ANY RESPONSIBILITY IN CASE OF NON
ADHERENCE TO THESE INSTRUCTIONS.
READ THIS USER MANUAL CAREFULLY.
INSTALLATION
Selection of installation location
Keep the unit on a flat surface and dry place.
Leave at least 50cm space all around the unit.
Installation
Fix the exhaust pipe into the adapter, and then fix the other side of the exhaust pipe into the air outlet
vent of the unit. (anti-clockwise)
Fix the adapter into the window slider kit, and then half open the window to meet the width of the
window slider kit. The length of the window slider kit is adjustable.
7
Incorrect mounting
The bend of the exhaust pipe is very important.
Incorrect mounting can prevent the machine from
working correctly.
Take care to prevent any sharp bows or bends of the
exhaust pipe.
The exhaust air must flow freely。
WARNING
The length of the exhaust pipe is specially designed according to the specification of this
product. Do not replace or prolong it with your own private hose as this could cause
mal-function.
BE CAREFUL: Maximum developed length of the exhaust pipe is 1500mm. Use the
shortest possible length. When mounting, we advise to keep the exhaust pipe in a
horizontal position.
PART NAME
3
2
1
Front
4
1. Control panel
2. Display
9
5
6
3. Button
4. Remote control receiver
5. Air outlet vent
6. Louver
8
7. Castor
8. Remote Control
7
8
9. Handle
10
Back
10. Exhaust air outlet vent
11. Power cord
12. Big filter
11
12
13. Small filter
14. Draining hole
13
14
Check all the accessories included in the package and please refer to the installation
instructions for their usage.
Accessories
Adapter
Exhaust pipe
Window slider kit B
Window slider kit A
9
CONTROL PANEL
1. POWER button: press this button to turn on/off the unit.
2. MODE button: press this button to select Cooling, Automatic adjusting mode or Fan
mode
3. SPEED button: press this button to select high, low fan speed
4. Timer: when stand-by time press this key to set automatic time on; when running time
press this key to set automatic time off.
5. UP button: press this button to set the temperature higher when cooling; press this
button to adjust time longer when timing; to exchange Fahrenheit and Celsius when
press both UP and Down button
6. DOWN button: press this button to set the temperature lower or higher when cooling;
press this button to adjust time shorter or longer when timing; to exchange Fahrenheit
and Celsius when press both UP and Down button.
10
REMOTE CONTROL
1. Power
2. Celsius and Fahrenheit exchange button
3. Fan button
7
4. Cool Mode Button
5. Auto mode button
6
5
8
6. Down button
4
9
7. Up button
3
8. High fan speed button
9. Low fan speed button
10. Max cool button
11. Sleep Mode
10
11
2
1
12
12. Timer button
11
OPERATION METHODS
Cooling mode
Default Cool mode after operating the machine or press Mode button to choose Cool mode,
the Cool mode indicator will flash.
·Press UP or DOWN button to set room temperature between 17℃ to 30℃.
·Press FAN SPEED button (or High/Low button) to select high, low fan speed.
Fan mode
·Press Fan button to choose Fan mode, the Fan mode indicator will flash.
·Select the fan speed by press SPEED button or press High / Low button directly.
·The temperature can not be set.
Automatic adjusting mode
·Press Mode button to choose the automatic mode. Automatic mode indicator will flash. After
choosing the automatic mode, the running state will depend on room temperature. When
room temperature is higher than 25℃, it will come into cool mode. On the contrary, it will be
fan mode. You can select the fan speed mode and timer mode when it is under automatic
adjusting mode.
Sleep Mode (Optional Function)
Press this button to activate or cancel sleep function in cooling mode
The unit will run at the low fan speed as default with lower noise. The setting temperature will
increase 1 degree per 2 hours running time, and it will not change after increasing 2 degrees
Max cool Mode (Optional Function)
Press this button to activate the Max cool mode.
The unit runs cool but is not restricted by the temperature under the Max cool mode
The unit is forced to be in high fan speed under the Max cool mode and the fan speed cant
be set。
Timer mode
.When the appliance is switch off, press Timer button to set timer-on.
·Press Up or Down button to adjust time from 0 to 24 hours. The Timer on indicator will flash.
When the appliance is running, press Timer button to set timer-off.
Press Up or Down button to adjust time from 0 to 24 hours. The Time off indicator
will flash.
12
WATER DRAINAGE
This product has a self-evaporative system. The condensing water will be recycled to cool
the condenser. This can not only improve cooling efficiency, but also save energy for you.
· If the inside water is full, the display panel will display “FL”, and the compressor will stop
running.
·Please turn the machine off and move the machine to the place where can drain water, and
then unplug the water-draining hole. After drainage, you can power it on and the machine will
run again.
MAINTENANCE
Note: Turn off the unit and unplug it before any maintenance or repair begins to
avoid electric shock.
Cleaning
·Unplug the unit before any cleaning.
·Clean the housing with a soft moisture cloth. Do not use chemical solvent (such as
benzene, alcohol, gasoline). The surface may be damaged or even the whole case may be
deformed.
·Do not sprinkle water on the unit.
Air filter
·Clean the air filter every 2 weeks. If the air filter is
blocked with dust, the efficiency will reduce.
·Open the air filter cover upwards, and then take out
the air filter.
·Wash the air filter by immersing it gently into warm
(about 40℃)waterwith a neutraldetergent,rinseitand
dry it thoroughly in a shaded place.
13
End of season
·Please drain the water.
·Keep the unit running in Fan mode for two hours until the inside of the unit is dry.
·Turn off the unit and unplug it.
·Clean the air filter and after dry it thoroughly, reinstall it.
·Remove the exhaust pipes and keep them carefully.
·Wrap the unit with the plastic bag and keep it in a dry place.
TROUBLE SHOOTING
Before contacting professional service, check it first yourself referring to the followings:
Problem
Cause
Solution
Connect to power supply outlet and
switch on.
No power supply.
The air
conditioner
does not
function.
“FL” flashes on the display
screen
Drain water.
You can turn on the unit three minutes
later.
Timer-off is running.
In direct sunlight.
Close curtains.
The air
conditioner
restart
Windows or doors open, many
people or a heat source in the
room.
Close doors and windows, remove the
heat source.
frequently
Dirty filter.
Air inlet or air outlet blocked.
Clean or replace the filter(s).
Remove the blockage.
The unit is too
noisy
Place on an even, solid surface (less
vibration).
Unit stands uneven.
No work of
compressor
Wait for 3 minute and restart again
after the descend of temperature
Self protect of compressor
Cautions: Switch off the unit and unplug it immediately if anything
abnormal happens. Then contact a qualified electrician.
Above data without advance notice for product improvement.
14
|