Husky Battery Charger HSK1084HD User Manual

HSK1084HD_Manual_062805.qxd 10/21/05 7:22 PM Page 8  
HSK1084HD  
Fu lly Au t o m a t ic Ele ct r o n ic  
Sm a r t Ba t t e r y Ch a r g e r  
1 0 / 6 / 2 Am p Ch a rg e Ra te s  
USER’ S M ANUAL  
& WARRANTY INFO RM ATIO N  
TO REDUCE THE RISK OF INJURY, USER MUST READ AND UNDERSTAND  
THIS INSTRUCTIO NAL MANUAL. THIS MANUAL CO NTAINS IMPO RTANT  
INFORMATION REGARDING THE OPERATION AND WARRANTY OF THIS  
PRODUCT. PLEASE RETAIN FOR FUTURE REFERENCE.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
HSK1084HD_Manual_062805.qxd 10/21/05 7:22 PM Page iv  
5. Carefully connect the NEGATIVE (BLACK) charger clamp to the free end of the battery cable  
connected to the NEGATIVE terminal.  
6. Set the charge rate to appropriate setting according to battery size.  
TABLE O F CO NTENTS  
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Features . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Controls and Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Operating Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Charge Rate Selection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Charging the Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Automatic Float Charging . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Alternator Check . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Approximate Charging Times . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Care and Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
Display Indications/ Common Problems/ Possible Solutions . . . . . . . . . . . . . . . .  
Charging a Very Cold Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  
1
2
2
3
3
4
4
4
5
5
6
6
6
7. When disconnecting charger, always do so in reverse sequence of connecting procedure and  
break first connection while as far away from battery as practical.  
N o te : A m a rin e (b o a t) b a tte ry m u st b e re m o ve d a n d ch a rg e d o n sh o re . To ch a rg e it  
o n b o a rd re q u ire s e q u ip m e n t sp e cia lly d e sig n e d fo r m a rin e u se . Th is u n it is  
N O T d e sig n e d fo r su ch u se .  
SAVE THESE IN STRUCTIO N S  
IN TRO DUCTIO N  
Thank you for selecting the Husk y Pro 1 0 / 6 / 2 Am p Sm a rt Ba tte ry Ch a rg e r.  
With proper care and use, it will give you years of dependable service. This battery  
charger has a high charge rate of up to 10 amps, and low charge rate of up to  
2 amps.  
Smart Battery Chargers feature 3-stage, high-efficiency charging technology, built-in  
microprocessor control that ensures fast, safe and complete charging of serviceable  
batteries.  
Ch a rg e Curve  
STAGE O N E  
BEEP  
BEEP  
STAGE TW O  
This device complies with part 15 of the FCC rules. Operation is subject to the following two  
conditions: (1) this device may not cause harmful interference, and (2) this device must accept  
any interference received, including interference that may cause undesired operation.  
STAGE THREE  
O FF BEEP  
CHARGIN G  
This equipment has been tested and found to comply with the limits for a Class B digital device,  
pursuant to part 15 of the FCC Rules. This limits are designed to provide reasonable protection  
against harmful interference in a residential installation. This equipment generates, uses and can  
radiate radio frequency energy and, if not installed and used in accordance with the  
instructions, may cause harmful interference to radio communications. However, there is no  
guarantee that interference will not occur in a particular installation. If equipment does cause  
harmful interference to radio or television reception, which can be determined by turning the  
equipment off and on, the user is encouraged to try to correct the interference by one or more  
of the following measures:  
CO MPLETE  
Sta g e O n e Rapid Start Charge at 10 amps delivers maximum charging  
amperage to “wake up” any serviceable 12 volt battery and allows for quick engine  
starting in just 5 minutes (based on a midsize vehicle battery at 50% charge level).  
When battery reaches a maximum safe predetermined voltage, the charger will  
automatically signal a "beep" and move into Stage 2 of the charging process.  
Sta g e Tw o Absorption Charge maintains the maximum possible charge at a  
constant, safe, predetermined voltage. During this phase, the charging voltage remains  
constant, while the actual charging current is reduced to allow for the maximum proper  
internal chemical energy transfer. At the end of Stage 2, the charger will automatically  
move into Stage 3 charge mode.  
Reorient or relocate the receiving antenna.  
Increase the separation between equipment and receiver.  
• Connect the equipment into an outlet on a circuit different from that to which the receiver is  
connected.  
• Consult the dealer or an experienced radio/ TV technician for help.  
iv  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
HSK1084HD_Manual_062805.qxd 10/21/05 7:22 PM Page 2  
Sta g e Three — Top-Off Charge voltage is automatically maintained and reduced to  
a predetermined level while current is adjusted for a safe, effective battery charge. At  
the end of Stage 3, the unit will BEEP signaling the completion of the charging cycle.  
INDICATORS:  
La rg e (.3 7 5 ” ) 3 -Ch a ra cte r Dig ita l Disp la y in the upper left of the control panel  
indicates the various conditions and/ or status codes:  
The Automatic Float Charge feature is ideal for maintaining a battery. It automatically  
tops off battery as needed, keeping it fully charged all the time.  
Status Codes are described in the following chart and on back of the charger.  
AC POWER INDICATOR - When connected to an AC outlet, digital display shows circulating pattern to indicate power is on.  
FEATURES  
Disconnect charger after use.  
FAULT CODES  
INTERNAL SHORTED CELL BATTERY - Cannot be charged. Have battery  
checked by certified auto service center.  
OVERHEATED CONDITION - Disconnect charger and allow to cool for 30 min.,  
check for ample ventilation.  
F05  
F01  
This unit has three charge rate settings, accessed by the 2/ 6/ 10 AMP button:  
a) 2 amps: smaller batteries, as in lawn mowers, snowmobiles, motorcycles, etc.  
b) 6 amps: mid-sized batteries, as in small cars  
c) 10 amps: automobiles and light trucks  
• Automatic float charge monitoring  
• Microprocessor controlled for proper operation and fault detection.  
Large, lighted digital display shows charging current, codes that indicate faults,  
modes of operation and time-out of functions  
• High-frequency, switch-mode operation for pure DC output  
Rapid charging three stage output  
• Heavy-duty cables and clamps are corrosion-resistant  
• Connect to side or top-mount battery terminals  
EXCESSIVE LOAD ON BATTERY WHILE CHARGING - Check load.  
BAD BATTERY CONNECTION - Check battery connection.  
BATTERY VOLTAGE TOO LOW TO ACCEPT CHARGE -  
Have battery checked by certified auto service center.  
OPERATION CODES  
F02  
ALTERNATOR VOLTAGE CHECK  
CHARGER STANDBY  
INTERNAL OPEN CELL/  
SULFATED CONDITION -  
F03  
F04  
000  
Have battery checked by certified auto service center.  
OVERTIME CONDITION - Battery will not accept a charge after 18 hours of continuous charging.  
Battery may have internal damage. Have battery chacked by certified auto service center.  
BATTERY CHARGE RATE IS SET TOO LOW - Set charger to higher charge rate. See manual.  
BATTERY FULLY CHARGED  
BATTERY IN FLOAT MODE  
FUL  
FLO  
CONTROL PANEL LED INDICATORS/ BUTTON:  
FAULT — lights when any of several faults are detected — see F01 through F05  
Codes as described in the previous chart. (If the Fault LED lights, refer to  
Troubleshooting” for details.)  
Rugged case, plus sturdy carry handle  
• Self-storage of cables and clamps  
Ideal during winter season when vehicle's starting performance is reduced by cold  
or extreme weather conditions  
• Single beep tone indicates a button is pressed or a mode change occurs  
• Alternator check can determine if alternator output is within a typical voltage range  
Re v. Po la rity lights when clamps are incorrectly connected to battery terminals.  
Ba tte ry Vo lta g e lights when the Battery Voltage button is pressed.  
Alte rn a to r Go o d Lights when load or no load checks show the alternator is  
keeping up with the electrical load.  
O PERATIN G IN STRUCTIO N S  
Co n tro ls a n d In d ica to rs  
CO N TRO L PAN EL  
En sure th a t a ll in sta lla tio n a n d o p e ra tin g in structio n s a n d sa fe ty  
p re ca u tio n s a re u n d e rsto o d a n d ca re fu lly fo llo w e d b y a n y o n e  
in sta llin g o r usin g th e ch a rg e r. Fo llo w th e ste p s o utlin e d in “ Im p o rta n t  
Sa fe ty In structio n s” a t th e fro n t o f th is m a n ua l.  
DIGITAL READO UT  
CIRCULATIN G PATTERN  
Ch a rg e Ra te Se le ctio n  
After charger clamps are correctly connected, plug in the charger to a 120 volt AC  
outlet and the charger will show a circulating pattern on the Digital Display, indicating  
power has been applied. Select the proper charge current rate based on battery size.  
WARN IN G  
If Dig ita l Disp la y sh o w s F0 2 ” a n d th e Fa ult in d ica to r lig h ts, th e  
co n n e ctio n to th e b a tte ry te rm in a ls is b a d . Fo llo w th e ste p s o utlin e d in  
“ Im p o rta n t Sa fe ty In structio n s” a t th e fro n t o f th is m a n ua l.  
FUNCTION BUTTONS (FROM RIGHT TO LEFT CLOCKWISE):  
2 / 6 / 1 0 AMP — allows the user to select the charge rate based on battery size. This  
selection and actual battery charge rate are monitored by the microprocessor and will  
stop charging if the selected rate is too fast or too slow for battery size or condition.  
If Re v. Po la rity in d ica to r a lso lig h ts, th e RED (PO SITIVE) a n d BLACK  
(NEGATIVE) cla m p s a re in co rre ctly co n n e cte d to b a tte ry te rm in a ls.  
Fo llo w th e ste p s o utlin e d in “ Im p o rta n t Sa fe ty In structio n s” a t th e  
fro n t o f th is m a n ua l.  
Ba tte ry Vo lta g e enables a check that measures the battery voltage.  
Alte rn a to r Ch e ck is a five-second check that measures the battery voltage. This  
check is repeated at various electrical load levels and the tests allow the user to  
determine if the alternator can keep up with the loads. It can indicate whether  
alternator service may be required.  
2
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
HSK1084HD_Manual_062805.qxd 10/21/05 7:22 PM Page 4  
1. Press Alternator Check to start the check.  
Ch a rg in g th e Ba tte ry  
2. Alternator Good LED will light to indicate the alternator is good, or  
the FAULT LED will light to indicate the alternator may need service.  
3. Press Alternator Check again to stop the test.  
1. Press 2/ 6/ 10 AMP button to begin charging at the 2 amp rate; the unit sounds  
a beep and displays charging current. The charger starts charging at 2 amp rate  
automatically if 2/ 6/ 10 AMP button is not pressed within 3 minutes after  
applying AC power.  
If the first alternator check indicates a good alternator and the second indicates the  
alternator may need service, the problem could stem from: loose fan belts, an  
intermittent diode failure or possibly bad connections between the battery and  
alternator and/ or ground.  
Charger occasionally sounds a beep and displays “0.0” during self-test or  
charging stage changes.  
2. Pressing the 2/ 6/ 10 AMP button again advances charging rate to 6 amps and  
pressing once more advances charging rate to 10 amps. (Pressing the button  
again will turn OFF the charger output and the Display will show “000.) This  
selection and actual battery charge rate are monitored by the microprocessor  
and the unit will stop charging if the selected rate is too fast or too slow for battery  
size or condition.  
N O TES BATTERY VO LTAGE b u tto n is d isa b le d in Alte rn a to r Ch e ck m o d e .  
Th e FAULT LED m a y lig h t b e ca u se so m e o n e h a s a d d e d a n u m b e r o f a cce sso ry  
lo a d s o n th e ch a rg in g sy ste m , th e re b y in cre a sin g cu rre n t d e m a n d fro m th e  
a lte rn a to r. MAKE SURE THAT THE ALTERN ATO R IS RATED TO SUPPO RT THE  
APPLICATIO N .  
Th is ch e ck m a y n o t b e a ccu ra te fo r e ve ry m a k e , m a n u fa ctu re r a n d m o d e l o f  
ve h icle .  
As the battery nears full charge capacity, the unit’s output will automatically drop  
to a lower charge rate.  
Ch e ck o n ly 1 2 vo lt sy ste m s.  
3. The battery charger displays the charge current. To view the battery voltage,  
press BATTERY VOLTAGE button. The charger will sound a beep and display the  
the battery voltage. Press BATTERY VOLTAGE again to return to displaying the  
charge current.  
APPRO XIMATE CHARGIN G TIMES  
The 2 / 6 / 1 0 Am p 1 2 Vo lt Sm a rt Ba tte ry Ch a rg e r will automatically adjust the  
charge rate as the battery becomes charged, and stop when the battery is fully  
charged. Deep cycle batteries may require longer charging time.  
4. The display shows “FULwhen the battery is fully charged.  
5. Disconnect the AC power cord first, then the NEGATIVE clamp, and finally the  
POSITIVE clamp.  
For estimates of the time it takes to charge a battery, refer to the following table.  
Pe rce n t o f ch a rg e  
Au to m a tic Flo a t Ch a rg in g  
Automatic Float Charging is ideal for maintaining a fully charged battery.  
1. Keep the AC power and battery connected after battery is fully charged.  
in b a tte ry  
7 5 %  
5 0 %  
2 5 %  
NR*  
0 %  
at 2 amp rate  
at 6 amp rate  
at 10 amp rate  
7 HRS  
14 HRS  
4.7 HRS  
2.8 HRS  
NR*  
2.5 HRS  
1.4 HRS  
7 HRS  
4.2 HRS  
9.2 HRS  
5.5 HRS  
2. The charger monitors the battery and tops it off as needed.  
3. The display shows “FLOwhen topping off the battery and returns to “FULwhen  
completed.  
*NR = Not recommended at 2 amps — use a higher charge rate.  
4. To view battery voltage, press the Battery Voltage button.  
N o te : Ch a rg in g ca n b e te rm in a te d b y p re ssin g th e 2 / 6 / 1 0 AMP b u tto n a t a n y tim e  
w h e n th e u n it is ch a rg in g .  
The times shown in the table above are approximate and refer to a 50 Ah automotive  
battery. For example, a 50 Ah (12 volt) battery is discharged (50%). How long  
should it be charged at the 10 amp rate? See the chart above under “50%” and “at  
10 amp rate.”  
Afte r AC p o w e r in te rru p tio n , ch a rg in g re sta rts a t 2 a m p ra te a u to m a tica lly.  
WARN IN G  
In most cases, battery charging times will vary depending on the size, age and  
condition of the battery. Smaller batteries should be charged at a lower rate (2 amps)  
and an extra hour added to charge time.  
If b a tte ry size is n o t k n o w n , ch a rg e a t th e  
o ve rch a rg e b a tte rie s.  
2
a m p ra te . DO NO T  
Alte rn a to r Ch e ck  
Pa rt 1  
CARE AN D MAIN TEN AN CE  
With proper care and minimal maintenance, the 2 / 6 / 1 0 Am p 1 2 Vo lt Sm a rt  
Ba tte ry Ch a rg e r will provide years of dependable service. For maximum  
performance, manufacturer recommends:  
No Load  
(Turn OFF all vehicles accessories): The battery must be fully charged  
before testing the alternator. Run the engine long enough to achieve  
normal idle speed and verify there is a no-load voltage.  
• After each use, clean the battery charger clamps — be sure to remove any battery  
fluid that will cause corrosion of the copper clamps.  
1. Press Alternator Check to start the check.  
2. Alternator Good LED will light to indicate the alternator is good, or  
the FAULT LED will light to indicate the alternator may need service.  
• Clean the outside case of the charger with a soft cloth and, if necessary, mild soap  
solution.  
3. Press Alternator Check again to stop the test.  
• Do not allow liquid to enter the charger. Do not operate when charger is wet.  
Pa rt 2  
Under Load (Accessories ON): Next, load the alternator by turning on as many  
Keep the charger cords loosely coiled during storage to prevent damage to the  
accessories as possible (except for A/ C and DEFROST)  
cords.  
4
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
HSK1084HD_Manual_062805.qxd 10/21/05 7:22 PM Page 6  
WARN IN GS  
• Do n o t use ch a rg e r if co rd s o r cla m p s h a ve b e e n d a m a g e d in a n y  
w a y — ca ll Te ch n ica l Sup p o rt to ll-fre e a t (8 6 6 ) 5 8 4 -5 5 0 4 .  
• Th e re a re n o use r-se rvice a b le p a rts in th is un it.  
• Do n o t o p e n th e un it. In th e e ve n t o f m a lfun ctio n , it m ust b e re turn e d  
to m a n ufa cture r fo r p ro fe ssio n a l te stin g a n d re p a ir. O PENING THE  
UNIT W ILL VO ID THE MANUFACTURER’S WARRANTY.  
TRO UBLESHO O TIN G  
Disp la y In d ica tio n s/ Co m m o n Pro b le m s/ Po ssib le So lu tio n s  
No Fun ctio n s  
• Check and make sure the charger is plugged into a live 110/ 120 volt AC outlet.  
• Follow the steps outlined in the Operating Instructions section.  
F0 1 — In te rn a l Sh o rte d Ce ll Ba tte ry  
If the battery being charged has an internal shorted cell, the F01 will show. We  
recommend taking your battery to a certified automotive service center for evaluation.  
F0 2 — Ba d Ba tte ry Co n n e ctio n o r Ba tte ry Vo lta g e To o Lo w to Acce p t  
Ch a rg e  
When F02 appears, the most common cause is poor connection to battery.  
• Follow the steps outlined in “Important Safety Instructions” at the front of this manual  
to disconnect AC cord and clamps, clean battery terminal and reconnect.  
If the situation persists, we recommend taking your battery to a certified automotive  
service center for evaluation.  
F0 3 — In te rn a l O p e n Ce ll  
Have battery checked by a certified automotive service center.  
F0 4 — O ve rtim e Co n d itio n  
F04 appears when charging time exceeds 18 hours.  
You may be using a charge current rate too low for a large battery. Select higher  
charge rate to charge the battery.  
F0 5 — O ve rh e a te d Co n d itio n  
The ventilation grill that prevents the air from flowing in and out of the charger may  
be blocked.  
• Follow the steps outlined in “Important Safety Instructions” at the front of this manual  
to disconnect AC cord and clamps, allow the unit to cool for 30 minutes and  
reconnect.  
• Make sure there is ample ventilation before resuming operation.  
Ch a rg in g a Ve ry Co ld Ba tte ry  
If the battery to be charged is very cold (in temperatures below freezing —  
0°C/ 32°F), it cannot accept a high rate of charge. The initial charge rate will be  
low. The charge rate will increase as the battery warms. Never attempt to charge a  
frozen battery.  
6
7
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Webcam 24K408 User Manual
Harbor Freight Tools Impact Driver 95666 User Manual
Heat Glo LifeStyle Boiler GRAND XTS User Manual
Hoshizaki Refrigerator PTR1SSB FGFG User Manual
Hotpoint Dishwasher Aquarius FDW20 User Manual
HP Hewlett Packard Digital Photo Frame df750 Series User Manual
HP Hewlett Packard Network Card HP GbE2c User Manual
HP Hewlett Packard Scanner 7400c User Manual
Hunter Fan Air Cleaner 30847 User Manual
Hunter Fan Fan 90397 User Manual