Hunter Fan Ventilation Hood 43042 01 User Manual

i
n
s t a l l a t i o  
n
G u i d e  
82048 Turino Bath Ventilator with Light  
READ and SAVE THESE INSTRUCTIONS  
1
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
x4  
x2  
A
B
C
I
* *  
Check all the parts.  
If damaged, call  
1-888-830-1326  
Extra screws  
for replacements.  
3/8” Cable Connector  
*
noTE: strain relief cable connector must be installed. not included.  
95044-01-000  
D
95029-01-000  
75191-01-000  
E
F
03242-07-133  
G
98037-01-000  
74508-03-133  
H
I
x2  
77521-01-000  
65219-01-000  
97959-01-000  
J
K
L
75729-01-000  
75184-01-133  
M
N
97960-01-000  
77535-01-000  
O
P
included.  
Tools needed.  
Estimated assembly time: 30 to 60 minutes  
3
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Before installation  
noTE: remove all packing materials before installation.  
2
1
I
H
Turn off the power source.  
Loosen screws.  
3
4
H
E
remove the motor/blower from the housing.  
remove packing material.  
5
6
remove the pre-loaded screw tip covers.  
Back out the pre-loaded screw tips until flush  
with the side of the housing.  
4
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
8
F
G
remove the wiring cover screw.  
remove the wiring cover.  
9
10  
E
C
B
pop out the first wiring access slug. Use second if needed.  
insert the strain relief into the housing and  
secure with the washer.  
Choose Installation Option  
For new Construction - attaching to joist fo to step a11, page 6  
For new Construction - suspended between joists go to step B11, page 8  
For Existing Construction - accessible from above go to step C11, page 11  
For Existing Construction - accessible only from below go to step D11, page 15  
5
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
new Construction attaching to joist  
A12  
A11  
E
5/8  
1/2  
position the correct depth mark at the bottom edge of the joist  
based on the thickness of your sheetrock.  
screw pre-loaded screws into joist or framing.  
A13  
pull wires through the strain relief.  
A14  
Ground  
Black  
2 pin  
Green  
Bare Copper  
White  
A
Black Main switch 1 (aC in)  
White  
Fan Motor  
White  
F
3 pin  
Black Light  
*option  
Light  
Black switch 2 (aC in)  
*option Fan & Main Light Together  
Connect wires as shown.  
6
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A16  
A15  
E
F
G
install the wiring cover plate. Make sure all  
wiring connections are inside the box or under  
the wiring cover plate.  
Connect 4” duct and vent to the outside. Tape joints.  
if ducting does not fit securely, an adapter may need  
to be purchased.  
0
A17  
A18  
H
Connect wiring from the motor to the wiring cover plate.  
reinstall the motor by inserting the tabs and pushing up into  
position. Make sure the wires are not pinched  
between the motor and the housing.  
A19  
A20  
I
secure the motor by tightening the 2 screws.  
Turn on the power source.  
7
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
A21  
A22  
Go to step  
o
n
E1  
o
on page 18  
FF  
to attach grille.  
Test the motor. if the motor does not run, check the plug  
connection.  
new Construction suspended between joists  
B11  
B12  
E
D
5/8  
1/2  
5/8  
1/2  
slide the mounting rails into brackets.  
position the correct depth mark at the bottom edge of  
the joist based on the thickness of your sheetrock.  
B14  
B13  
1/8" Bit  
E
Mark position of screws by using holes as a template.  
Drill a hole in the center of each outline.  
8
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B16  
B15  
insert screws, leaving space between the screw  
head and the joist. screws are not provided.  
attach the rails onto the screws.  
B18  
B17  
Tighten screws.  
pull wires through the strain relief.  
B19  
Ground  
Black  
White  
Green  
2 pin  
Bare Copper  
A
Black Main switch 1 (aC in)  
White  
Fan Motor  
White  
F
3 pin  
Black Light  
*option  
Light  
Black switch 2 (aC in)  
*option Fan & Main Light Together  
Connect wires as shown.  
9
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B20  
B21  
F
G
install the wiring cover plate. Make sure all wiring  
connections are inside the box or under the  
wiring cover plate.  
Connect 4” duct and vent to the outside. Tape joints.  
if ducting does not fit securely, an adapter may need  
to be purchased.  
B22  
B22  
H
H
Connect wiring from the motor to the wiring cover plate.  
reinstall the motor by inserting the tabs and pushing up into  
position. Make sure the wires are not pinched  
between the motor and the housing.  
B25  
B24  
I
secure the motor by tightening the 2 screws.  
Turn on the power source.  
10  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
B26  
B27  
Go to step  
o
n
E1  
on page 18  
o
FF  
to attach grille.  
Test the motor. if the motor does not run,  
check the plug connection.  
Existing Construction accessible from above  
EXisTinG Fan  
C11  
no EXisTinG Fan  
OR  
remove an existing fan and check to make sure the  
opening is large enough to accommodate the new  
motor housing (8”x 8.5”).  
Use the motor housing as a template to mark position.  
C12  
E
D
8
Cut out an opening for the housing.  
slide the mounting rails into brackets.  
11  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C13  
C14  
5/8  
1/2  
5/8  
1/2  
position the correct depth mark at the bottom edge of the joist  
based on the thickness of your sheetrock.  
Mark position of screws by using holes as a template.  
C16  
C15  
1/8" Bit  
Drill a hole in the center of each outline.  
insert screws, leaving space between the screw head  
and the joist. screws are not provided.  
C18  
C17  
attach the rails onto the screws.  
Tighten screws.  
12  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C19  
C20  
Connect 4” duct and vent to the outside. Tape joints.  
pull wires through the strain relief.  
if ducting does not fit securely, an adapter may  
need to be purchased.  
C21  
Tighten the strain relief screws.  
C22  
Ground  
Black  
White  
Green  
2 pin  
3 pin  
Bare Copper  
A
Black Main switch 1 (aC in)  
White  
Fan Motor  
Light  
White  
F
Black Light  
*option  
Black switch 2 (aC in)  
*option Fan & Main Light Together  
Connect wires as shown.  
13  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C24  
C23  
H
F
G
install the wiring cover plate. Make sure all wiring  
connections are inside the box or under the  
wiring cover plate.  
Connect wiring from motor the motor  
to the wiring cover plate.  
C25  
C26  
H
I
reinstall the motor by inserting the tabs and pushing up into  
position. Make sure the wires are not pinched  
between the motor and the housing.  
secure the motor by tightening the 2 screws.  
C28  
C27  
o
n
o
FF  
Turn on the power source.  
Test the motor. if the motor does not run,  
check the plug connection.  
14  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
C29  
Go to step  
E1  
on page 18  
to attach grille.  
Existing Construction accessible only from below  
EXisTinG Fan  
D11  
D12  
E
remove an existing fan and check to make sure the opening  
is large enough to accommodate the new motor housing (8”x  
8.5”).  
Move the housing into position above the ceiling.  
D13  
D14  
2
1
attach existing ducting to duct connector. Tape joints.  
if ducting does not fit securely,  
pull wires through strain relief.  
an adapter may need to be purchased.  
15  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D15  
E
install the housing flush with the sheetrock and secure by tight-  
ening the pre-loaded screws into the joist.  
D16  
Ground  
Green  
Black  
2 pin  
Bare Copper  
White  
A
Black Main switch 1 (aC in)  
White  
Fan Motor  
White  
F
3 pin  
Black Light  
*option  
Light  
Black switch 2 (aC in)  
*option Fan & Main Light Together  
Connect wires as shown.  
D18  
D17  
F
H
G
install the wiring cover plate.  
Connect wiring from the motor to the wiring cover plate.  
16  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
D19  
D20  
H
I
reinstall the motor by inserting the tabs and pushing up into  
position. Make sure the wires are not pinched between the mo-  
tor and the housing.  
secure the motor by tightening the 2 screws.  
D22  
D21  
o
n
o
FF  
Turn on the power source.  
Test the motor. if the motor does not run, check the plug con-  
nection.  
D23  
Go to step  
E1  
on page 18  
to attach grille.  
17  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E1  
E2  
L
K
remove the thumbscrews.  
Connect wiring harness.  
E4  
E3  
J
K
remove the strain relief bracket screw.  
position the strain relief bracket under the motor as shown.  
E6  
E5  
insert the strain relief bracket’s dog-leg tab so that it hooks  
over the lip of the motor. reinstall the strain relief bracket  
screw.  
align posts a, B, C and D (stamped into motor housing) with  
posts a, B, C and D (stamped into light fixture). slide light  
fixture over posts.  
18  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
E8  
E7  
N
attach thumbscrews.  
install 2 Max 60 Watt a15 bulbs (not included).  
WarninG: To reduce the risk of electrical shock,  
all 4 thumbscrews MUsT be properly installed.  
E9  
E10  
O
M
screw glass stop into position.  
align glass dome and push up.  
E11  
E12  
P
Complete.  
screw Finial into position  
19  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Trouble shooting  
problem: Fan does not come on.  
solution:  
• Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand  
near the vents to feel the air movement.  
• Turn power on, replace fuse, or reset breaker.  
• Check all plug connections to be sure they are secure.  
• Check the wiring to make sure it matches the wiring diagram.  
problem: Light does not come on.  
solution:  
• Replace the light bulb with a new bulb.  
• Turn power on, replace fuse, or reset breaker.  
• Check all plug connections to be sure they are secure.  
• Check the wiring to make sure it matches the wiring diagram.  
problem: Fan is noisy.  
solution:  
• Check and tighten all fasteners.  
• Check the glass to make sure it is secure.  
• Check the flapper to make sure it moves freely.  
if you need parts or service assistance, please call 888-830-1326 or visit us at our web site at http://www.  
hunterfan.com.  
20  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warranty  
Hunter Fan Company  
Bath Exhaust Fan  
LiMiTED WarranTY  
Hunter Fan Company makes the following limited warranty to the original user or consumer purchaser of this Hunter  
bath  
exhaust fan:  
If any part of your Hunter bath exhaust fan (except for glass fixtures and light bulbs) fails at any time within one year  
afterthe date of sale to you due to a defect in material or workmanship, we will repair or, at our option, replace the  
defective part free of charge for parts and labor performed at our nearest service center or at our service Depart-  
ment in Memphis, Tennessee. after this one-year period, you will be responsible for all parts and labor costs for  
repairs on the bath exhaust fan except for motor repairs as provided below.  
If your Hunter bath exhaust fan motor fails at any time within five years after the date of sale to you due to a defect  
in material or workmanship, labor and materials to repair the defect will be provided free of charge at our nearest  
service center or our service Department in Memphis, Tennessee. if no replacement part can be provided, we  
will, at our option, either refund the actual purchase price of your bath exhaust fan or provide a replacement free of  
charge. After this five-year period, you will be responsible for all parts and labor costs for repairs on all parts of the  
bath exhaust fan.  
iF THE oriGinaL UsEr or ConsUMEr pUrCHasEr CEasEs To oWn THE Fan, THis WarranTY anD  
anY iMpLiED WarranTY WHiCH THEn rEMains in EFFECT, inCLUDinG BUT noT LiMiTED To anY iM-  
pLiED WarranTY oF MErCHanTaBiLiTY or FiTnEss For a parTiCULar pUrposE, arE VoiDED. no  
WarranTY, EXprEss or iMpLiED, inCLUDinG anY WarranTY oF MErCHanTaBiLiTY or FiTnEss For  
a parTiCULar pUrposE, is MaDE in rEspECT oF GLass FiXTUrEs or LiGHT BULBs or THE FinisH  
on anY METaL porTion oF THE BaTH EXHaUsT Fan.  
THis WarranTY is in LiEU oF aLL oTHEr EXprEss WarranTiEs. THE DUraTion oF anY iMpLiED  
WarranTY, inCLUDinG, BUT noT LiMiTED To, anY iMpLiED WarranTY oF MErCHanTaBiLiTY or FiT-  
nEss For a parTiCULar pUrposE, in rEspECT To anY HUnTEr Fan BaTH EXHaUsT Fan MoTor or  
oTHEr Fan parT, is EXprEssLY LiMiTED To THE pErioD oF THE EXprEss WarranTY sET ForTH  
aBoVE For sUCH MoTors or oTHEr parTs.  
This warranty is voided if your Hunter bath exhaust fan is not purchased and installed in the U.s.a. This warranty  
excludes and does not cover defects, malfunctions or failures of any Hunter bath exhaust fan which were caused  
by repairs by persons not authorized by us, use of parts or accessories not authorized by us, mishandling, improper  
installation, modifications or damage to the Hunter bath exhaust fan while in your possession, or unreasonable use,  
including failure to provide reasonable and necessary maintenance.  
To obtain servicing, contact the nearest Hunter authorized service center of the Hunter Fan Company service De-  
partment, 2500 Frisco avenue, Memphis, Tennessee 38114. please contact us before shipping your bath exhaust  
fan to us. if we authorize you to ship it to us, you will be responsible for all insurance and freight or other transpor-  
tation charges to our factory or service center. We will return your Hunter bath exhaust fan freight prepaid. Your  
Hunter bath exhaust fan should be properly packed to avoid damage in transit since we will not be responsible for  
any such damage. proof of purchase is required when requesting warranty service. The purchaser must present the  
sales receipt or other document that establishes proof of purchase.  
in no EVEnT sHaLL HUnTEr Fan CoMpanY BE LiaBLE For ConsEQUEnTiaL or inCiDEnTaL DaM-  
aGEs.  
soME sTaTEs Do noT aLLoW LiMiTaTions on HoW LonG an iMpLiED WarranTY LasTs or THE EX-  
CLUsion or LiMiTaTion oF inCiDEnTaL or ConsEQUEnTiaL DaMaGEs so THE aBoVE LiMiTaTion or  
EXCLUsions MaY noT appLY To YoU.  
THE WarranTY GiVEs YoU spECiFiC LEGaL riGHTs anD YoU MaY aLso HaVE oTHEr riGHTs WHiCH  
VarY FroM sTaTE To sTaTE  
.
© 2008 Hunter Fan Company  
21  
43042-01 02/21/2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Swing PD123415B User Manual
Grizzly Switch H8242 User Manual
Havis Shields Automobile Accessories KK C VAK User Manual
Havis Shields Laptop Docking Station DS DELL 101 User Manual
Heath Zenith Work Light 52 4477 8 User Manual
HP Hewlett Packard Noise Reduction Machine 11 User Manual
HP Hewlett Packard Scanner 5400c Series 4400c Series User Manual
HTC Headphones P6500 User Manual
IBM Personal Computer 4190 User Manual
Impex Tent MS 93 User Manual