3
INTRODUCTION  
Read This Before Installing Thermostat  
Features  
5
7
INSTALLATION  
What You Need  
8
8
Remove Old Thermostat  
Wire Labeling  
9
Mount Wallplate and Thermostat  
Connect Wires and Mount Thermostat Cover to Wall Plate  
Selector Switches  
11  
12  
13  
PROGRAMMING  
Setting Time and Day  
14  
16  
17  
18  
19  
21  
22  
23  
Default Programs  
Personal Program Schedule  
Manual Programming  
Weekday / Weekend Programming  
7-Day Programming  
Reviewing Programs  
Reviewing the Current Temperature Setting  
OPERATIONS  
System Selector Switch  
Fan Switch  
24  
24  
25  
Temporary Manual Override  
(continued)  
41665-01.pmd Download from Www.Som3 anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
Table of Contents (continued)  
4
OPERATIONS (continued)  
Permanent Manual Override  
26  
27  
28  
30  
31  
32  
34  
Vacation Override (Programmable Hold)  
Home Today  
Energy Monitor  
Filter Monitor  
Auto Recovery  
SPAN Setting Mode  
SAFETY FEATURES  
Low Battery Warning  
Error Mode  
36  
37  
37  
Auto Cut-Off  
TROUBLESHOOTING  
WIRING DIAGRAMS  
Problems & Solutions  
Technical Support  
38  
39  
Heat / Cool Systems  
40  
41  
Single-Stage Heat Pump Systems  
Heat Only / Cool Only Systems  
41-42  
41665-01.pmd Download from Www.Som4 anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
Read This Before Installing Thermostat  
5
IMPORTANT  
air conditioning, or space heating units in use in the  
United States.  
Read the entire installation section of this  
1Owner’s Manual thoroughly before you begin  
to install or operate your Hunter Thermostat.  
This Hunter Thermostat will NOT control multi-  
stage heat pumps or 110/220 Volt systems.  
REMOVE THE MYLAR LABEL FROM THE LCD DISPLAY  
WINDOW.  
COMPRESSOR PROTECTION  
The thermostat provides a 3.5 minute delay after  
5shutting off the heating or cooling system before  
it can be restarted. This feature will prevent damage  
to your compressor caused by rapid cycling. Note  
that this delay also applies to the heating system  
control. It does not prevent a rapid compressor re-  
start due to short power outages.  
INSTALLATION  
All installation is normally performed at your  
2thermostat.  
ARMCHAIR PROGRAMMING  
You can program your thermostat before  
3installation by inserting the batteries and following  
the instructions starting on page 16. This can be done  
while you relax in your favorite chair and is a very  
good way to familiarize yourself with all the functions  
of your Hunter Thermostat.  
TEMPERATURE RANGE  
Your thermostat can be programmed between  
64°C and 35°C (45°F and 95°F). However, it will  
display room temperatures from 0°C and 37°C (32°F  
to 99°F). “HI” will be displayed if the temperature is  
higher than 37°C (99°F), and “LO” will be displayed  
if the temperature is lower than 0°C (32°F).  
OPERATION  
Your Thermostat is designed to operate with  
4most gas, oil, electric or 2-wire hot water heating  
and air conditioning systems. It will also operate  
single-stage heat pumps that do not have auxiliary  
or emergency heat. These have 24-volt or millivolt  
control systems and represent most central heating,  
This thermostat will automatically cut off in Heat  
mode if the temperature rises above 35°C (95°F),  
and automatically cut off in cool mode if the tem-  
perature drops below 7°C (45°F).  
41665-01.pmd Download from Www.Som5 anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
Read This Before Installing Thermostat (continued)  
6
POWER FAILURE  
change the batteries and keep thermostat’s clock and  
program settings. Once the batteries have become too  
low to ensure proper operation, your system will be  
turned Off, and the display will be cleared except for  
the Low Battery indicator flashing on the LCD display.  
Whenever the main power is interrupted or fails,  
7the battery power retains the programs and cur-  
rent time.  
AUTO RECOVERY  
Your thermostat is set from the factory to gradually  
8recover the room temperature from an energy sav-  
ing program to your comfort program. Therefore, the  
thermostat may turn your system on several minutes  
prior to your programmed time. This operation is nor-  
mal, but can be turned off. Refer to the Selector  
Switches information on page 24.  
CAUTION: Once the Low Battery only display oc-  
curs, the thermostat is shut down, and your sys-  
tem will no longer operate. In this condition,  
there is no temperature control of your dwelling.  
NOTE: If you plan to be away from the premises  
over 30 days, we recommend that you replace  
the old batteries with new alkaline batteries  
prior to leaving.  
BATTERY WARNING  
Fresh alkaline batteries should provide over one  
9year of service. However, when the batteries be-  
come drained, the Low Battery indicator will flash on  
the display. When this message occurs, install 2 new  
AA batteries. You have approximately 1 minute to  
ENERGY STAR® Partner  
As an ENERGY STAR® Partner, Hunter Fan Co. has  
determined that this programmable thermostat meets  
the ENERGY STAR® guidelines for energy efficiency.  
41665-01.pmd Download from Www.Som6 anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
Features  
7
Home Today: Overrides  
energy-saving program  
temperatures while you are  
home for the day.  
Up and Down Keys: Keys for changing  
LCD Display: Shows time, day, temperature, program  
number, and other feature information as required.  
the Temperature setting. Also used for  
increasing and decreasing selections in  
the Time, Program, and Span functions.  
Energy: Measures and  
displays heating and  
cooling system  
Program Key: Used for entering  
and modifying Programs. Use  
with the Up and Down keys to  
set times and temperatures.  
Press when in Clock setting  
mode to select between 12 and  
24 hour clock modes.  
operating time for  
Today, Yesterday, This  
Week, Last Week, or  
Total. By monitoring  
your energy usage, you  
SA  
home  
AM  
2
energy  
HEAT  
TEMP  
can program the  
thermostat to optimize  
energy savings.  
today  
system  
Filter Key: Resets Filter Change  
counter to zero.  
heat  
cool  
program  
off  
System Switch:  
Selector switch for  
Heat, Cool, and Off  
day/time  
prog day  
reset  
filter  
Day / Time Key: Used for  
entering the Clock setting mode.  
Use with the Up and Down keys  
to set the time and day.  
fan  
auto  
on  
hold  
/return  
Fan Switch: Fan  
switch for Automatic  
or Continuous fan  
operation.  
Hold / Return Key: Used for  
setting a permanent or vacation  
hold, and for returning to the  
normal display from Day & Time  
setting, Programming, or Span  
setting modes.  
Program Day Key: Selects the day  
or days to review or change in the  
Program mode.  
Battery Release Lever:  
Push to pop batteries loose.  
Reset: Press with a paper clip to reset the  
thermostat and return to power-up settings.  
41665-01.pmd Download from Www.Som7 anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
INSTALLATION  
8
What You Need  
This thermostat includes two #8 screws and two wall  
anchors for mounting. To install your thermostat, you  
should have the following tools and materials.  
Phillips and Slotted Screwdrivers  
Hammer  
Electric drill and 3/16" bit  
Two 1.5 V (AA) size alkaline batteries  
Remove Old Thermostat  
CAUTION: Do not remove any wiring from exist-  
ing thermostat before reading the instructions  
carefully. WIRES MUST BE LABELED PRIOR TO  
REMOVAL.  
TYPICAL HOME THERMOSTATS  
Figure 1  
IMPORTANT! Turn off the power to the furnace at  
the main power panel or at the furnace.  
Remove existing thermostat cover. See Figure 1.  
Some thermostats will have screws or other lock-  
ing devices that must first be removed. Once wall  
mounting plate is exposed, look for wires.  
Wall Mounting Plate  
Wall Mounting Plate  
Thermostat  
Thermostat  
Cover  
If wires are not visible, they may be connected to the  
back of the wallplate. Again, look for screws, tabs,  
etc. Some models have doors that open to expose  
wires and mounting screws. (See Figure 1).  
Cover  
41665-01.pmd Download from Www.Som8 anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
Wire Labeling  
9
Each wire coming from the wall to the existing  
thermostat is connected to a terminal point on  
that thermostat. Each of these terminal points is  
usually marked with a code letter as shown in  
Table A on the next page.  
IMPORTANT! BEFORE DISCONNECTING ANY  
WIRES, APPLY THE SELF-ADHESIVE LABELS PRO-  
VIDED TO THE WIRE AS SHOWN IN TABLE A ON  
THE NEXT PAGE. (For example, attach the label  
marked W to the wire that goes to the W or H  
terminal on your existing thermostat.) IGNORE  
THE COLOR OF THE WIRES since these do not  
always comply with the standard.  
Note that this thermostat has multiple function  
terminals that allow Single-Stage Heat Pump ca-  
pability. Standard systems use: Rh, Rc, G, W.  
[Single-Stage Heat Pumps use: Rh, Y1, G, and O or  
B.] Table A below shows the multiple functions of  
the terminals. Use the terminals that match your  
system.  
After labeling wires, disconnect them from the  
existing thermostat terminals.  
Remove existing wallplate. To make sure wires do  
not fall back into wall opening, you may want to  
tape them to the wall.  
If hole in wall is larger than necessary for wires,  
seal this hole with insulating material so that no  
hot or cold air can enter the back of the thermo-  
stat from the wall. This air could cause a false  
thermostat reading.  
The number of wires in your system can be as few  
as two (for heat only systems), as many as eight,  
or any number in between. If you follow the label-  
ing procedures correctly, you do not have to be  
concerned about how many wires there are.  
There is often no ter-  
minal marking on the  
G
Y
existing thermostat of  
two wire, heat only  
systems. Just connect  
either of the wires to  
the RH terminal, then  
connect the other wire  
to the W terminal to  
complete the circuit.  
W
RH  
RC  
(continued)  
41665-01.pmd Download from Www.Som9 anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
INSTALLATION  
10  
If the code letter on your  
existing thermostat is  
then mark the wire  
with label shown  
and connect to thermostat  
terminal shown  
RH  
RH, R, VR or 4  
24 Volt  
x
RC  
RC, VC  
x
24 Volt Cool  
G
G or F  
Fan  
x
Y, C or M  
Air Conditioning Compressor  
Y/O  
- or -  
x
O
Reversing Valve operating in Cool mode.  
(Single Stage Heat Pumps ONLY.)  
Y/O  
W or H  
Heating  
W/B  
- or -  
x
B
Reversing Valve operating in Heat mode.  
(Single Stage Heat Pumps ONLY.)  
Y1  
Y1  
x
Heat Pump compressor  
(Single Stage Heat Pumps ONLY.)  
Table A  
NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat.  
Tape up the wire and do not use. This wire provides electricity to non-battery powered thermostats.  
41665-01.pmd Download from Www.Som10anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
Mount Wallplate and Thermostat  
11  
Remove the wallplate from your thermostat by  
pressing the release tab on the bottom of the  
thermostat. (See Figure 2.)  
Position wallplate on wall and pull existing wires  
through large opening. Then level for appearance.  
Mark holes for plastic anchors provided if your  
existing holes do not line up with those on the  
Hunter wallplate.  
Drill holes with 3/16” bit and gently tap anchors  
into the holes until flush with wall.  
Reposition wallplate to wall, pulling wires through  
large opening. Insert mounting screws provided  
into wall anchor and tighten. (See Figure 3.)  
G
Figure 2  
Figure 3  
NOTE: 5-wire Systems  
If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and  
RC terminals on the wallplate.  
Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH  
and RC terminals.  
41665-01.pmd Download from Www.Som11anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
INSTALLATION  
12  
Connect Wires and Mount Thermostat Cover to Wall Plate  
Match and connect the labeled wires to the appro-  
priate coded terminal screws on the wallplate. (See  
Figure 4, 5.) Ignore any wires which may be present,  
but which were not connected to the old thermostat.  
the thermostat onto the wallplate, as the ter-  
minal pins may be damaged. If it does not  
snap properly, the thermostat may not work.)  
Insert the two AA size alkaline batteries, observing  
Refer to the Wiring Diagrams below to be sure your  
the polarity marked inside the battery compartment.  
system is wired correctly.  
Switch on the main power at the panel or furnace.  
If your system is a single-stage heat pump and  
uses an O or B wire, you must move the System  
Selector switch inside the thermostat to the Heat  
Pump position. If you have a normal furnace or  
electric system, leave the switch in the Standard  
position. Refer to the System Selector section on  
the back for more information on this switch.  
RH  
x
G
Rc Rh Y/O W/B Y1  
Figure 4  
Figure 5  
Be sure to tighten the terminal screws securely,  
otherwise a loose wire could cause operational  
problems with your system or thermostat.  
Push excess wire back into the hole to prevent interfer-  
ence when installing the thermostat to the wallplate.  
Make sure the System Switch is set to OFF, and the  
Fan Switch is set to AUTO.  
Insert the bottom tab on the thermostat body into  
the slot at the bottom of the wallplate. Press the  
top of the thermostat body to snap it into the  
wallplate. Refer to Figure 6. (NOTE: Do not force  
Figure 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
41665-011pmd  
Selector Switches  
13  
In order for this Hunter thermostat to control your  
system, the system type must be specified by se-  
lector switches on the printed circuit board inside  
the thermostat.  
Furnace or Heat Pump selector (STD - HP switch)  
The factory position for this switch is in the STD  
position. Leave it in this position if you have ANY  
system that uses gas, oil, electric, or hot water heating.  
NOTE: When changing these features after instal-  
lation, move the HEAT / COOL selector switch  
to OFF before removing the thermostat from  
the wall.  
If you have a single-stage Heat Pump (no auxiliary  
or emergency heat source), then slide the switch to  
the HP position.  
Auto Recovery selector (DISABLE / ENABLE)  
System Selector Switches:  
Your thermostat is set from the factory with the Auto  
Recovery Feature enabled, which complies with the  
EPA ENERGY STAR® Program. If you prefer to use  
normal recovery, slide the switch to the ALT position.  
Refer to page 32 for a complete discussion of the  
Auto Recovery feature.  
Heating system selector (HG – HE switch)  
The factory position for this switch is in the “HG”  
position. Leave it in this position if you have a gas  
furnace or an oil burner.  
If you have an electric furnace, test to see  
whether the Heat and Fan come on as expected.  
If Fan operation is normal, leave the switch in the  
“HG” position.  
Auto Recovery  
(SW2)  
ENABLE  
DISABLE  
If the Fan does not come on within a minute of  
the thermostat calling for Heat, change the switch  
position to “HE.”  
System Selector  
(SW5)  
STD  
HG  
HP  
Fan Option  
(SW6)  
The system selector has no effect in the cool-  
ing mode.  
HE  
NOTE: “HG” position is for gas and most  
other systems. “HE” position is for certain  
electric systems having a fan relay.  
Figure 7  
41665-01.pmd Download from Www.Som13anuals.com. All Manuals Search9A/3n0/d03D, 4o:w52nPloMad.  
PROGRAMMING  
14  
Setting Time and Day  
The LCD will show this information when batteries  
are first installed, or after the Reset button is  
pressed. The temperature will update after a few  
seconds.  
During time and day setting mode, the temperature  
and program displays will go blank.  
Example: Set the Thermostat to the current time of  
2:16 pm on Saturday. Refer to the Steps below.  
STEP 1:  
Press to enter time and day setting mode. The cur-  
rent hour and the AM / PM indicator will be flashing.  
Press to change the Hour up or down to the  
current hour.  
STEP 3:  
STEP 4:  
Press again to change from minute setting to day  
setting. The current day will be flashing.  
M
day/time  
PM  
Press to change the Day up or down to the  
current day.  
SA  
Press again to change back to the  
normal display.  
day/time  
PM  
or  
2
hold  
TEMP  
/return  
NOTE: You may press  
normal display.  
at any time during Day and Time setting to return to the  
hold  
/return  
DAYLIGHT SAVING TIME  
SA  
SET TEMP  
Press and hold.  
day/time  
AM  
Press to enter Daylight Saving Time.  
2
TEMP  
or  
(continued)  
41665-01.pmd Download from Www.Som15anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
PROGRAMMING  
16  
Setting Time and Day (continued)  
12 HR. / 24 HR. TIME FORMAT  
Minute, or Day is flashing to toggle between the 12  
hour and 24 hour formats. The AM / PM indicator will  
not be displayed in 24 hour mode. Both the current  
time and all programs will automatically change to the  
selected format.  
Your thermostat is set from the factory in normal 12  
(AM / PM) time format. To change to 24 hour (military)  
program  
time, press  
at any time while the Hour,  
Default Programs  
Studies conducted by the Department of Energy esti-  
mate that setting your thermostat back 6°C (10°F) for  
two 8-hour periods during winter can reduce your fuel  
bill by as much as 33%. By setting your thermostat up  
3°C (5°F) for two 8-hour periods during summer you  
can reduce your fuel bill up to 25%.  
Your Hunter thermostat is pre-programmed to meet  
the ENERGY STAR® guidelines for energy efficiency.  
The thermostat is pre-programmed for all 7 days of the week as shown below.  
Temperature in C° (F°)  
Program Number  
Time  
6:00am  
8:00am  
4:00pm  
10:00pm  
Heat  
Cool  
1
2
3
4
20°C (68°F)  
16°C (60°F)  
20°C (68°F)  
16°C (60°F)  
26°C (78°F)  
29°C (85°F)  
26°C (78°F)  
28°C (82°F)  
Refer to Manual Programming on page 18 for instructions on entering or changing the programs.  
41665-01.pmd Download from Www.Som16anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Personal Program Schedule  
17  
Use a pencil so you can revise your records each time  
you change your temperature settings.  
Before programming or changing programs, use this  
Personal Program Schedule to determine which times  
and temperature settings will best satisfy both your  
comfort and energy saving requirements.  
Heating  
Cooling  
Day Prog. 1  
Prog. 2  
Time  
Prog. 3  
Prog. 4  
Day Prog. 1  
Prog. 2  
Time  
Prog. 3  
Prog. 4  
Mon. Time  
Temp  
Time  
Time  
Mon. Time  
Temp  
Time  
Time  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Tues.  
Time  
Time  
Time  
Time  
Tues.  
Time  
Time  
Time  
Time  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Wed. Time  
Temp  
Time  
Time  
Time  
Wed. Time  
Temp  
Time  
Time  
Time  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Thurs. Time  
Temp  
Time  
Time  
Time  
Thurs. Time  
Temp  
Time  
Time  
Time  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Fri.  
Time  
Time  
Time  
Time  
Fri.  
Time  
Time  
Time  
Time  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Sat.  
Sun.  
Time  
Time  
Time  
Time  
Sat.  
Sun.  
Time  
Time  
Time  
Time  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Time  
Time  
Time  
Time  
Time  
Time  
Time  
Time  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
Temp  
41665-01.pmd Download from Www.Som17anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
PROGRAMMING  
18  
Manual Programming  
Your thermostat can be programmed for week-  
days and weekends, or have unique programs for  
all 7 days. Use Weekday/Weekend Programming  
below or 7-day Programming on page 21 to enter  
or revise programs to match your Personal Pro-  
gram Schedule.  
Familiarize yourself with Manual Programming, so  
that you can easily modify your programs as your  
comfort needs change. The example below dem-  
onstrates how to program your thermostat.  
NOTE: 1) The program time can be set in 10  
minute increments, and remains the  
same for both Heat and Cool programs.  
2) The program temperature can be set  
in increments of 1°C (1°F).  
3) After 15 seconds without a key press,  
the thermostat will return to normal  
display mode.  
4) When setting the program time, note  
the AM / PM indicator.  
5) With the Auto Recovery feature en-  
abled, you do not need to set your  
comfort program times early. Auto  
Recovery will determine how early to  
turn your system on, so that the room  
is comfortable at the program time.  
41665-01.pmd Download from Www.Som18anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Weekday/Weekend Programming  
system  
heat  
Slide System Selector Switch to HEAT or COOL to  
program the corresponding system.  
off  
cool  
NOTE: If the system selector is in the OFF position, no programming is  
permitted. The LCD display will show only dashes when the program key is pressed.  
Press to enter program mode. HEAT or COOL will  
be displayed on the LCD.  
M
T
W
TH  
F
program  
AM  
1
HEAT  
The Program hour and AM or PM indicator are  
flashing. Press to change the hour.  
Press again to change to the minute position.  
The current minute will be flashing.  
M
T
W
TH  
F
program  
AM  
Press to change the minute.  
1
HEAT  
(continued)  
41665-01.pmd Download from Www.Som19anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
PROGRAMMING  
20  
Weekday/Weekend Programming (continued)  
Press again to change to the program temperature.  
program  
M
T
W
TH  
F
The current temperature will be flashing.  
AM  
Press to change the temperature.  
1
HEAT  
Press again to move to the next program number.  
program  
Repeat steps 3 - 5 to change the remaining  
weekday programs.  
Press to change to weekend programs.  
SA SU  
prog day  
AM  
Repeat steps 3 - 5 to change the weekend programs.  
Press to exit Program mode, or wait 15 seconds to  
1
hold  
HEAT  
exit automatically.  
/return  
41665-01.pmd Download from Www.Som20anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
7-Day Programming  
system  
Slide System Selector Switch to HEAT or COOL to  
program the corresponding system.  
heat  
off  
cool  
M
Press to enter program mode, display shows week-  
day programs.  
AM  
AM  
AM  
program  
prog day  
1
Press 2 times to reach the Monday program.  
HEAT  
M
program  
keys to set  
Use  
,
and  
the 4 programs for Monday.  
1
HEAT  
Press to change to the next day’s programs.  
T
prog day  
Repeat Step 2 to complete the selected day’s programs.  
Continue repeating Steps 2 and 3 to program all 7  
days of the week.  
1
HEAT  
When finished press to return to normal mode.  
After 15 seconds, the thermostat will return to  
normal mode automatically.  
hold  
/return  
Change the System Selector Switch to the other  
system, and repeat Steps 1 through 4 above.  
41665-01.pmd Download from Www.Som21anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
PROGRAMMING  
22  
Reviewing Programs  
You may want to review the programs to confirm that the settings are compatible with your lifestyle.  
Weekday  
Programs  
Press to display M – F programs.  
M
T
W
TH  
F
program  
AM  
Press repeatedly to cycle through the 4 programs.  
1
HEAT  
Weekend  
Programs  
Press to display the Sa – Su programs.  
SA SU  
prog day  
program  
PM  
3
Press repeatedly to cycle through the 4 programs.  
HEAT  
Daily  
Programs  
Press to display M – F programs.  
NOTE: Time and Temperature display will be  
blank when at least one weekday program  
is different.  
M
T
W
TH F  
program  
prog day  
Press to change to Sa – Su. Again, if the display is  
blank, one of the weekend programs is different.  
41665-01.pmd Download from Www.Som22anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Daily  
Programs  
(cont.)  
Press again to change to Monday’s program.  
Continue pressing to cycle through each day.  
Press repeatedly to cycle through the 4 programs.  
M
prog day  
program  
AM  
1
HEAT  
Press to return to normal mode.  
hold  
/return  
After 15 seconds, the thermostat will return to nor-  
mal mode automatically.  
NOTE: Programs take affect as soon as the thermostat returns to normal mode.  
If you are armchair programming the thermostat, slide the system selector to the OFF position before  
mounting the thermostat to the wallplate.  
Reviewing the Current Temperature Setting  
Current time and temperature.  
SA  
PM  
3
HEAT  
TEMP  
Press for 1 second or less.  
SET TEMP  
or  
Set Temperature is shown above current room  
temperature.  
3
HEAT  
TEMP  
If held for over 1 second, Temporary Manual Over-  
ride mode is entered. Refer to the next page.  
41665-01.pmd Download from Www.Som23anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
OPERATION  
24  
System Selector Switch  
The System Selector switch on the front of the thermostat determines the operating  
mode of the thermostat. You may select COOL, OFF, HEAT.  
system  
heat  
off  
NOTE: Anytime you install or remove the thermostat from the wallplate,  
slide the System Selector to the OFF position to prevent the possibility  
of a rapid system On-Off.  
cool  
Fan Switch  
fan  
The Fan switch should normally be located in the AUTO position. The Fan will be  
turned on along with normal operation of your system. In a normal gas or oil furnace,  
the Fan will be turned on by your furnace after its warm-up delay. For electric heat, air  
conditioning, and heat pump operation, the Fan will turn on with the system.  
auto  
on  
To run the Fan on continuously, slide the Fan switch to the ON position.  
41665-01.pmd Download from Www.Som24anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Temporary Manual Override  
25  
To temporarily change the current set temperature without affecting your program:  
Press and hold for about 1 second to enter Manual  
SET TEMP  
Override mode. When display flashes, you can  
release the key.  
or  
3
COOL  
TEMP  
Press again to change to your desired Set Tempera-  
ture. Hold the key for 2 seconds to fast-advance the  
Set Temperature.  
or  
Press to return to normal mode, or wait 5 seconds  
for it to return automatically.  
hold  
/return  
The current program number will flash to signify the  
SA  
Temporary Override.  
PM  
At the next program change time, the Temporary  
Override is cancelled, and the next program tem-  
perature becomes the setpoint temperature.  
3
COOL  
TEMP  
To end the Temporary Manual Override:  
Press and wait for HOLD to display on the LCD.  
Press again. This will return the set temperature to the current program set temperature.  
hold  
/return  
41665-01.pmd Download from Www.Som25anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
OPERATION  
26  
Permanent Manual Override  
To hold your Manual Override for vacation or just an extended period of time:  
Press to make the current program temperature the  
HOLD temperature. HOLD will be displayed on the  
LCD, and the Program number will disappear.  
TH  
PM  
Follow the Temporary Manual Override instructions  
above to change the Permanent Manual Override  
temperature.  
TEMP  
You can confirm the held set temperature by press-  
ing for less than 1 second.  
To end the Permanent Manual Override:  
Press again. The thermostat will return to the current  
program, and the HOLD display will be canceled.  
hold  
/return  
Vacation Override (Programmable Hold)  
This thermostat can hold a fixed temperature for a selected number of days (up to 30). After the selected number  
of days, the thermostat will return to normal program operation. This feature allows you to return home to your  
normal comfort setpoint temperatures.  
Press and hold for 2 seconds. Display will change to  
show a 1 day hold.  
SET TEMP  
hold  
/return  
HOLD  
COOL  
TEMP  
Press to select the number of days to set the  
vacation hold temperature. In this example,  
14 is used.  
SET TEMP  
day/time  
HOLD  
COOL  
TEMP  
Press to set the desired temperature.  
or  
Press to return to normal mode, or wait 5 seconds  
for it to return automatically.  
hold  
/return  
HOLD will be shown on the LCD, and “VACA” will  
alternate with the time.  
HOLD  
TEMP  
41665-01.pmd Download from Www.Som27anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
OPERATION  
28  
Home Today  
This Hunter patented feature allows you to quickly and temporarily override your energy saving program setting on  
days when you are normally away from home with one key press.  
home  
Press to enter the Home Today override. The highest  
program temperature for today will be selected from  
your programs in Heat mode and become the set  
temperature. (In Cool mode, Home Today will select  
the lowest program temperature for today to be the  
set temperature.)  
F
AM  
HOME TODAY  
TEMP  
HEAT  
today  
The display will flash “HOME TODAY” and the pro-  
gram number will disappear.  
When pressed during the first or second program of  
the day, Home Today will automatically return to  
program control at the start of the fourth program  
of the day. If Home Today is pressed after the start of  
the third program time of the day, the thermostat  
will remain in Home Today mode until the first pro-  
gram of the next day.  
home  
today  
If Home Today is already active, you may similarly  
extend it to the first program of the next day by  
pressing the key again after the start time of the  
third program.  
41665-01.pmd Download from Www.Som28anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
If the system is changed between Heat and Cool modes during the “Home Today”  
override period, the setpoint temperature will be automatically updated. It will auto-  
matically change from the highest heat program setpoint to the lowest cool program  
setpoint, or from the lowest cool program setpoint to the highest heat program setpoint.  
Press to exit Home Today mode before the schedule ending time. “HOME TODAY”  
is no longer displayed on the LCD screen, and the thermostat returns to the  
current program.  
hold  
/return  
You can manually change the setpoint temperature while in Home Today mode. Refer  
to the Temporary Manual Override instructions on page 24. Manually changing the set  
temperature while in Home Today mode will not affect the Home Today ending time.  
However, the set temperature will not change automatically with a manual or Auto-  
matic change between heating and cooling.  
home  
today  
You may also press the HOME TODAY key while in Temporary Manual Override. The  
operation is the same as the previous point above.  
41665-01.pmd Download from Www.Som29anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
OPERATION  
30  
Energy Monitor  
The Energy monitor feature measures and stores the  
amount of time the heating and air conditioning sys-  
tem operates. Usage can be displayed for Today (since  
12am), Yesterday, This Week (since Monday), Last  
Week (last Monday through Sunday), and Total (up to  
999 Hrs. 59 Min.). By monitoring your energy  
usage, you see how much the set-back periods  
are saving and you can test program adjustment  
to save even more. Use table on page 17.  
To review energy usage, press to cycle through To-  
day, Yesterday, This Week, Last Week, and Total.  
Press again to return to normal mode, or wait 15  
seconds for the display to return to normal mode.  
You can also return to normal mode at any time by  
pressing RETURN.  
Hr  
energy  
Min  
Usage Today  
For example: This LCD display shows Today’s usage  
to be 10 Hours, 26 minutes.  
Press and hold for 3 seconds to reset the Energy  
Monitor’s counters. The display will blink, and all  
counters will be cleared to zero.  
energy  
NOTE: Clearing the Energy Monitor counter will also clear the Filter Monitor counter, as Filter  
usage and Total Energy usage are the same. Also, clearing the Filter Monitor counter will  
clear ALL Energy Monitor counters as well.  
41665-01.pmd Download from Www.Som30anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Filter Monitor  
31  
Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system’s  
performance and energy efficiency, change or clean your filter regularly.  
When the total system run time for heat and cool  
W
reaches 400 hours, FILTER will flash on the LCD  
display to remind you to clean or change your  
PM  
FILTER  
system’s filter. FILTER will continue to flash until  
2
the counter is set back to zero.  
COOL  
TEMP  
Press to review total filter usage. The display will  
blink FILTER ,then show the Filter Monitor counter.  
After 15 seconds, the display will return to normal  
mode, or you can hit RETURN to exit immediately.  
The Filter Monitor will display up to 999 hours and  
59 minutes of usage.  
filter  
In this example, the counter is at 410 Hours,  
26 minutes.  
Hr  
FILTER  
To reset the Filter Monitor counter, depress FILTER  
for 3 seconds. The display will blink, and the counter  
will be reset to zero.  
Min  
NOTE: Clearing the Filter Monitor counter will also clear ALL Energy Monitor counters, as Filter  
usage and Total Energy usage are the same. Also, clearing the Energy Monitor counters will  
clear the Filter Monitor counter as well.  
41665-01.pmd Download from Www.Som31anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
OPERATION  
32  
Auto Recovery  
Hunter’s Auto Recovery feature meets the ENERGY  
STAR® guidelines for energy efficiency by allowing the  
heating or cooling system to recover gradually from an  
energy-saving setpoint temperature to a comfort  
setpoint temperature.  
For example, in Heat mode, you could have the follow-  
ing programs:  
Program #4 (Overnight)  
Set Temp = 16°C  
Time = 10pm  
Program #1 (Morning)  
Set Temp = 20°C  
Time = 6am  
Auto Recovery calculates how early to turn your sys-  
tem back On, so that the room temperature is already  
comfortable by the start of the comfort temperature  
program period. Auto Recovery works in both Heat  
and Cool modes.  
The room temperature fell to 16°C overnight. Rather  
than having the thermostat turning on at 6am, Auto  
Recovery would note the temperature difference be-  
tween 16°C and 20°C and turn the Heat on approxi-  
mately 30 minutes early. Therefore, the room tempera-  
ture at 6am would be about 20°C instead of 16°C.  
When the thermostat is in Auto Recovery mode, the display will  
alternate RECO with time, and the program indicator will flash.  
4
HEAT  
TEMP  
41665-01.pmd Download from Www.Som32anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Details of Auto Recovery Operation:  
33  
Auto Recovery can be disabled by sliding the Re-  
covery switch on the circuit board to the DISABLE  
position. Refer to page 13.  
Auto Recovery will be canceled and change to  
Home Today mode if HOME TODAY is pressed  
during the recovery process.  
Auto Recovery will not operate if Permanent hold,  
Temporary hold or Home Today is in operation.  
Auto Recovery will be canceled and change to  
Temporary Manual Override mode if the setpoint  
is adjusted during the recovery process.  
Auto Recovery can be canceled manually if HOLD/  
RETURN is pressed during the recovery process. If a  
recovery process is canceled manually then the re-  
covery process will not start again until the next  
program period starts (an exception is that if time  
or program is changed then the thermostat will  
check Auto Recovery conditions immediately).  
If the system is changed between heat and cool  
then the thermostat will recalculate Auto Recov-  
ery again. Setpoint temperature will be changed  
to the opposite system’s comfort temperature if  
the recovery entry criteria are still met. Otherwise,  
the recovery process will be canceled and return  
to program control mode.  
41665-01.pmd Download from Www.Som33anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
OPERATION  
34  
SPAN Setting Mode  
Your thermostat is set at the factory to cycle at  
0.5˚C (1˚F) above and below the set temperature.  
(Span = 2) This setting has been designed to pro-  
vide a comfortable room temperature under most  
all conditions. However, if you find your system  
cycling too fast or too slow, then the Span can be  
adjusted to modify the cycle time.  
Press and hold BOTH for three seconds. The display  
will flash, and SPAN will be displayed on the LCD.  
Press to raise the Span to 3. This setting INCREASES  
the cycle time by allowing your system to run  
LONGER.  
Press to lower the Span to 1. This setting  
DECREASES the cycle time by causing your  
system to run SHORTER.  
41665-01.pmd Download from Www.Som34anuals.com. All Manuals Search9A/3n0/d03D, 5o:w40nPloMad.  
The Span settings remain the same for both HEAT  
and COOL.  
When batteries are installed in the thermostat, or  
the Reset key is pressed, the Span is reset back to  
setting 2.  
The Span can be changed at any time, and is inde-  
pendent of program times or temperatures.  
41665-01.pmd Download from Www.Som35anuals.com. All Manuals Search9A/3n0/d03D, 5o:w40nPloMad.  
SAFETY FEATURES  
36  
Error Mode  
37  
If the thermostat is unable to control your system due to an unex-  
pected battery problem, the thermostat will enter Error Mode. In  
this condition, the thermostat flashes “Err” on the LCD display, and  
shuts off your system. To correct this problem, replace the batteries  
with 2 new AA alkaline batteries, even if you have recently replaced  
them. Next, use a paper clip to press the RESET button next to the  
keypad. You will need to reprogram your thermostat and confirm  
normal operation.  
If Error Mode returns, please call Hunter Technical support at  
1-866-268-1936 for further information.  
Auto Cut Off  
Your thermostat will automatically cut-off in Heat  
mode if the room temperature rises above 35˚C (95˚F).  
It will cut-off in Cool mode if the room temperature  
drops below 4˚C (40˚F).  
NOTE: If your system has malfunctioned and no  
longer responds to thermostat controls, the Auto  
Cut-Off will have no effect.  
41665-01.pmd Download from Www.Som37anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
TROUBLESHOOTING  
38  
Problem  
Solution  
1. Remove clear mylar sticker.  
Scrambled or Double Display  
(numbers over numbers)  
No Display  
1. Check battery connections and batteries.  
2. Press RESET button with a small pin and hold in for two seconds.  
Entire Display Dims  
1. Replace Batteries.  
Program Does Not Change at  
your Desired Setting  
1. Check that the time is set properly to AM” or “PM”.  
2. Check that the thermostat is not in “HOLD” or “Home Today” modes.  
3. Check for the correct day setting.  
Auto / Fan Does Not turn On  
1. Move HG/HE selector to opposite position  
Heating or Cooling Does Not  
Go On or Off  
1. Check that the system selector switch is in the correct position  
(“HEAT,” “COOL).  
2. There may be as much as a 4 minute delay before the Heat or Cool  
system turns On - wait and check. (Compressor protection delay.)  
3. Check your circuit breakers and switches to ensure there is power to  
the system.  
4. Replace batteries.  
5. Make sure your furnace blower door is closed properly.  
6. If your system only uses 4-wires, be sure the jumper wire is installed  
between the RC and RH terminals.  
7. Check the position of the Furnace or Heat Pump selector switch: STD - HP.  
41665-01.pmd Download from Www.Som38anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Problem (cont.)  
Solution (cont.)  
39  
Erratic Display  
1. Press the RESET button once with a small pin and hold for two  
seconds. The thermostat will need to be re-programmed.  
If unit continues to operate in  
the Off position  
1. Replace unit.  
1. Replace unit.  
Thermostat permanently reads  
“HI,” “LO,” or “ERR-” after  
pressing reset button  
If you experience any other problems, call 1-866-268-1936 from 8 AM to 5 PM Central Time for technical assis-  
tance.  
41665-01.pmd Download from Www.Som39anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
WIRING DIAGRAM
40  
4-wire Heat/Cool System  
System  
Selector  
Wallplate  
Terminals  
Jumper  
STD HP  
Rh  
Y/O  
W/B  
G
Rc  
Y1  
X
X
Heat/Cool  
24V Supply  
Heat Relay  
or Valve  
Cool  
Fan  
Contactor  
Relay  
5-wire Heat/Cool System  
System  
Selector  
Wallplate  
Terminals  
No Jumper  
STD HP  
Rh  
Y/O  
W/B  
G
Rc  
Y1  
X
Fan  
Heat Relay  
or Valve  
Cool 24V  
Supply  
Heat 24V  
Supply  
Cool  
Relay  
Contactor  
X - No Connection  
41665-01.pmd Download from Www.Som40anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Single-stage Heat Pump  
41  
System  
Selector  
Wallplate  
Terminals  
Jumper  
STD HP  
Y1  
G
Rc  
Rh  
Y/O  
Cool  
Mode  
W/B  
Heat  
Mode  
OR  
X
Fan  
Heat Pump  
24V Supply  
Reversing  
Valve  
Compressor  
Contactor  
Relay  
Connect to Proper Reversing  
Valve Terminal. See Table A  
2-wire Heat Only  
System  
Selector  
Wallplate  
Terminals  
Jumper  
STD HP  
Rh  
Y/O  
W/B  
G
Rc  
Y1  
X
X
X
X
Heat 24V or  
Heat Relay  
or Valve  
Millivolt Supply  
X - No Connection  
41665-01.pmd Download from Www.Som41anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
WIRING DIAGRAM
42  
3-wire Heat Only  
System  
Selector  
Wallplate  
Terminals  
Jumper  
STD HP  
Rh  
Y/O  
W/B  
G
Rc  
Y1  
X
X
X
Heat 24V  
Supply  
Heat Relay  
or Valve  
Fan  
Relay  
3-wire Cool Only  
System  
Selector  
Wallplate  
Terminals  
Jumper  
STD HP  
Rh  
Y/O  
W/B  
G
Rc  
Y1  
X
X
X
Fan  
Cool 24V  
Supply  
Cool  
Contactor  
Relay  
X - No Connection  
41665-01.pmd Download from Www.Som42anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  
Humidifiers  
Fans  
AirPurifiers  
OtherQualityProductsfromHunter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
.hunterfan.com  
orvisitTheHunterFanCompanywebsite:www  
,call1-800-4HUNTER,  
estHunterDealer  
o
u
r
L
ATo41l6o  
o
6
c
5
a
s-  
t
0
e
1co  
0
u
p
r
kmned  
a
ar  
Y
l
R
e
t
a
i
l
e
r
f
o
r
43  
9/30/03,  
4:532PM  
9 / 0 3  
. 4 1 6 6 5 - 0 o 1 r m , N o  
a n C o m p a H n u y n t F e r F © 2 0 0 3 ,  
A R I O , O L 6 N T O T 2 N W 4 B R A M P T  
®
, S U I A T D E 2 0 7  
4 5 B R A M A L E A R O  
a n C o m p H a u n n y t C e a r n F a d a  
41665-01.pmd Download from Www.Som44anuals.com. All Manuals Search9A/3n0/d03D, 4o:w53nPloMad.  

Haier Flat Panel Television HL26R User Manual
Hamilton Beach Kitchen Utensil 840147200 User Manual
Heath Zenith Door 598 1172 04 User Manual
HP Hewlett Packard Network Card HP E5123A User Manual
HP Hewlett Packard Printer 2100 User Manual
Huffy Fitness Equipment 89224 User Manual
Humminbird Fish Finder 408710 1 User Manual
Husqvarna Trimmer 324L 324LD User Manual
Hypertec Carrying Case N14598KHY User Manual
IGo Direct Mouse PPC 6700 User Manual