41644_model44360_web.pmd
1
®
Programmable Thermostat
M
AM
4
TEMP
Owner’s Manual
Model 44360
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
4
Table of Contents (continued)
4
OPERATIONS (continued)
Permanent Manual Override
Vacation Override (Programmable Hold)
Home Today
26
27
28
30
31
32
34
35
Energy Monitor
Filter Monitor
Auto Recovery
SPAN Setting Mode
Backlighting
SAFETY FEATURES
Low Battery Warning
Error Mode
36
37
37
Auto Cut-Off
TROUBLESHOOTING
WIRING DIAGRAMS
Problems & Solutions
Technical Support
38
39
Heat / Cool Systems
40
41
Single-Stage Heat Pump Systems
Heat Only / Cool Only Systems
41-42
5
Read This Before Installing Thermostat
5
IMPORTANT
air conditioning, or space heating units in use in the
United States.
Read the entire installation section of this
1Owner’s Manual thoroughly before you begin
to install or operate your Hunter Thermostat.
This Hunter Thermostat will NOT control multi-
stage heat pumps or 110/220 Volt systems.
REMOVE THE MYLAR LABEL FROM THE LCD DISPLAY
WINDOW.
COMPRESSOR PROTECTION
The thermostat provides a 3.5 minute delay after
5shutting off the heating or cooling system before
it can be restarted. This feature will prevent damage
to your compressor caused by rapid cycling. Note
that this delay also applies to the heating system
control. It does not prevent a rapid compressor re-
start due to short power outages.
INSTALLATION
All installation is normally performed at your
2thermostat.
ARMCHAIR PROGRAMMING
You can program your thermostat before
3installation by inserting the batteries and following
the instructions starting on page 16. This can be done
while you relax in your favorite chair and is a very
good way to familiarize yourself with all the functions
of your Hunter Thermostat.
TEMPERATURE RANGE
Your thermostat can be programmed between
645°F and 95°F (4°C and 35°C). However, it will
display room temperatures from 32°F to 99°F (0°C
and 37°C). “HI” will be displayed if the temperature
is higher than 99°F (37°C), and “LO” will be dis-
played if the temperature is lower than 32°F (0°C).
OPERATION
Your Thermostat is designed to operate with
4most gas, oil, electric or 2-wire hot water heating
and air conditioning systems. It will also operate
single-stage heat pumps that do not have auxiliary
or emergency heat. These have 24-volt or millivolt
control systems and represent most central heating,
This thermostat will automatically cut off in Heat
mode if the temperature rises above 95°F (35°C),
and automatically cut off in cool mode if the tem-
perature drops below 45°F (7°C).
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
6
Read This Before Installing Thermostat (continued)
6
POWER FAILURE
change the batteries and keep thermostat’s clock and
program settings. Once the batteries have become too
low to ensure proper operation, your system will be
turned Off, and the display will be cleared except for
the Low Battery indicator flashing on the LCD display.
Whenever the main power is interrupted or fails,
7the battery power retains the programs and cur-
rent time.
AUTO RECOVERY
Your thermostat is set from the factory to gradually
8recover the room temperature from an energy sav-
ing program to your comfort program. Therefore, the
thermostat may turn your system on several minutes
prior to your programmed time. This operation is nor-
mal, but can be turned off. Refer to the Selector
Switches information on page 24.
CAUTION: Once the Low Battery only display oc-
curs, the thermostat is shut down, and your sys-
tem will no longer operate. In this condition,
there is no temperature control of your dwelling.
NOTE: The INDIGLO® night-light will not function
when the thermostat is in low battery condition.
BATTERY WARNING
Fresh alkaline batteries should provide over one
9year of service. However, when the batteries be-
come drained, the Low Battery indicator will flash on
the display. When this message occurs, install 2 new
AA batteries. You have approximately 1 minute to
NOTE: If you plan to be away from the premises
over 30 days, we recommend that you replace
the old batteries with new alkaline batteries
prior to leaving.
ENERGY STAR® Partner
As an ENERGY STAR® Partner, Hunter Fan Co. has
determined that this programmable thermostat meets
the ENERGY STAR® guidelines for energy efficiency.
7
Features
7
Home Today: Overrides
Up and Down Keys: Keys for changing
the Temperature setting. Also used for
increasing and decreasing selections in
the Time, Program, and Span functions.
LCD Display: Shows time, day, temperature, program
number, and other feature information as required.
energy-saving program
temperatures while you are
home for the day.
Energy: Measures and
displays heating and
cooling system
Program Key: Used for entering
and modifying Programs. Use
with the Up and Down keys to
set times and temperatures.
Press when in Clock setting
mode to select between 12 and
24 hour clock modes.
operating time for
Today, Yesterday, This
Week, Last Week, or
Total. By monitoring
your energy usage, you
SA
home
AM
2
energy
HEAT
TEMP
y
a
d
can program the
thermostat to optimize
energy savings.
to
system
Filter Key: Resets Filter Change
counter to zero.
heat
cool
program
filter
off
System Switch:
Selector switch for
Heat, Cool, and Off
day/time
prog day
reset
Day / Time Key: Used for
entering the Clock setting mode.
Use with the Up and Down keys
to set the time and day.
fan
auto
on
hold
/return
Fan Switch: Fan
switch for Automatic
or Continuous fan
operation.
Hold / Return Key: Used for
setting a permanent or vacation
hold, and for returning to the
normal display from Day & Time
setting, Programming, or Span
setting modes.
Program Day Key: Selects the day
or days to review or change in the
Program mode.
Battery Release Lever:
Push to pop batteries loose.
Reset: Press with a paper clip to reset the
thermostat and return to power-up settings.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
8
INSTALLATION
8
What You Need
■ Phillips and Slotted Screwdrivers
■ Hammer
■ Electric drill and 3/16" bit
■ Two 1.5 V (AA) size alkaline batteries
This thermostat includes two #8 screws and two wall
anchors for mounting. To install your thermostat, you
should have the following tools and materials.
Remove Old Thermostat
TYPICAL HOME THERMOSTATS
Figure 1
CAUTION: Do not remove any wiring from exist-
ing thermostat before reading the instructions
carefully. WIRES MUST BE LABELED PRIOR TO
REMOVAL.
■ IMPORTANT! Turn off the power to the furnace at
the main power panel or at the furnace.
■ Remove existing thermostat cover. See Figure 1.
Some thermostats will have screws or other lock-
ing devices that must first be removed. Once wall
mounting plate is exposed, look for wires.
Wall Mounting Plate
Wall Mounting Plate
Thermostat
Thermostat
Cover
If wires are not visible, they may be connected to the
back of the wallplate. Again, look for screws, tabs,
etc. Some models have doors that open to expose
wires and mounting screws. (See Figure 1).
Cover
9
Wire Labeling
9
■
Each wire coming from the wall to the existing
thermostat is connected to a terminal point on
that thermostat. Each of these terminal points is
usually marked with a code letter as shown in
Table A on the next page.
■ IMPORTANT! BEFORE DISCONNECTING ANY
WIRES, APPLY THE SELF-ADHESIVE LABELS PRO-
VIDED TO THE WIRE AS SHOWN IN TABLE A ON
THE NEXT PAGE. (For example, attach the label
marked W to the wire that goes to the W or H
terminal on your existing thermostat.) IGNORE
THE COLOR OF THE WIRES since these do not
always comply with the standard.
■ Note that this thermostat has multiple function
terminals that allow Single-Stage Heat Pump ca-
pability. Standard systems use: Rh, Rc, G, W.
[Single-Stage Heat Pumps use: Rh, Y1, G, and O or
B.] Table A below shows the multiple functions of
the terminals. Use the terminals that match your
system.
■ After labeling wires, disconnect them from the
existing thermostat terminals.
■ Remove existing wallplate. To make sure wires do
not fall back into wall opening, you may want to
tape them to the wall.
■ The number of wires in your system can be as few
as two (for heat only systems), as many as eight,
or any number in between. If you follow the label-
ing procedures correctly, you do not have to be
concerned about how many wires there are.
■ If hole in wall is larger than necessary for wires,
seal this hole with insulating material so that no
hot or cold air can enter the back of the thermo-
stat from the wall. This air could cause a false
thermostat reading.
■ There is often no ter-
minal marking on the
G
Y
existing thermostat of
two wire, heat only
systems. Just connect
either of the wires to
the RH terminal, then
connect the other wire
to the W terminal to
complete the circuit.
W
RH
RC
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
10
INSTALLATION
10
If the code letter on your
existing thermostat is
then mark the wire
with label shown
and connect to thermostat
terminal shown
RH
RH, R, VR or 4
24 Volt
x
RC
RC, VC
x
24 Volt Cool
G
G or F
Fan
x
Y, C or M
Air Conditioning Compressor
Y/O
- or -
x
O
Reversing Valve operating in Cool mode.
(Single Stage Heat Pumps ONLY.)
/O
Y
W or H
Heating
W/B
- or -
x
B
Reversing Valve operating in Heat mode.
(Single Stage Heat Pumps ONLY.)
Y1
Y1
x
Heat Pump compressor
(Single Stage Heat Pumps ONLY.)
Table A
NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on this thermostat.
Tape up the wire and do not use. This wire provides electricity to non-battery powered thermostats.
11
Mount Wallplate and Thermostat
11
■ Remove the wallplate from your thermostat by
pressing the release tab on the bottom of the
thermostat. (See Figure 2.)
■ Position wallplate on wall and pull existing wires
through large opening. Then level for appearance.
Mark holes for plastic anchors provided if your
existing holes do not line up with those on the
Hunter wallplate.
■ Drill holes with 3/16” bit and gently tap anchors
into the holes until flush with wall.
■ Reposition wallplate to wall, pulling wires through
large opening. Insert mounting screws provided
into wall anchor and tighten. (See Figure 3.)
G
Figure 2
Figure 3
NOTE: 5-wire Systems
If your thermostat has one wire marked R or RH (4-wire system), then leave the jumper wire between the RH and
RC terminals on the wallplate.
Otherwise, if you have separate RH and RC wires (5-wire system), then remove the jumper wire between the RH
and RC terminals.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
12
INSTALLATION
12
Connect Wires and Mount Thermostat Cover to Wall Plate
■ Match and connect the labeled wires to the appro-
priate coded terminal screws on the wallplate. (See
Figure 4, 5.) Ignore any wires which may be present,
but which were not connected to the old thermostat.
the thermostat onto the wallplate, as the ter-
minal pins may be damaged. If it does not
snap properly, the thermostat may not work.)
■ Insert the two AA size alkaline batteries, observing
■ Refer to the Wiring Diagrams below to be sure your
the polarity marked inside the battery compartment.
system is wired correctly.
■ Switch on the main power at the panel or furnace.
■ If your system is a single-stage heat pump and
uses an O or B wire, you must move the System
Selector switch inside the thermostat to the Heat
Pump position. If you have a normal furnace or
electric system, leave the switch in the Standard
position. Refer to the System Selector section on
the back for more information on this switch.
■ Be sure to tighten the terminal screws securely,
otherwise a loose wire could cause operational
problems with your system or thermostat.
RH
x
G
Rc Rh Y/O W/B Y1
Figure 4
Figure 5
■ Push excess wire back into the hole to prevent interfer-
ence when installing the thermostat to the wallplate.
■ Make sure the System Switch is set to OFF, and the
Fan Switch is set to AUTO.
■ Insert the bottom tab on the thermostat body into
the slot at the bottom of the wallplate. Press the
top of the thermostat body to snap it into the
wallplate. Refer to Figure 6. (NOTE: Do not force
Figure 6
13
Selector Switches
13
In order for this Hunter thermostat to control your
system, the system type must be specified by se-
lector switches on the printed circuit board inside
the thermostat.
■
Furnace or Heat Pump selector (STD - HP switch)
The factory position for this switch is in the STD
position. Leave it in this position if you have ANY
system that uses gas, oil, electric, or hot water heating.
NOTE: When changing these features after instal-
lation, move the HEAT / COOL selector switch
to OFF before removing the thermostat from
the wall.
If you have a single-stage Heat Pump (no auxiliary
or emergency heat source), then slide the switch to
the HP position.
■ Auto Recovery selector (DISABLE / ENABLE)
System Selector Switches:
Your thermostat is set from the factory with the Auto
Recovery Feature enabled, which complies with the
EPA ENERGY STAR® Program. If you prefer to use
normal recovery, slide the switch to the ALT position.
■ Heating system selector (HG – HE switch)
The factory position for this switch is in the “HG”
position. Leave it in this position if you have a gas
furnace or an oil burner.
Refer to page 32 for a complete discussion of the
Auto Recovery feature.
If you have an electric furnace, test to see
whether the Heat and Fan come on as expected.
If Fan operation is normal, leave the switch in the
“HG” position.
Auto Recovery
(SW2)
ENABLE
DISABLE
If the Fan does not come on within a minute of
the thermostat calling for Heat, change the switch
position to “HE.”
System Selector
(SW5)
STD
HG
HP
Fan Option
(SW6)
The system selector has no effect in the cool-
ing mode.
HE
NOTE: “HG” position is for gas and most
other systems. “HE” position is for certain
electric systems having a fan relay.
Figure 7
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
14
PROGRAMMING
14
Setting Time and Day
■ The LCD will show this information when batteries
M
are first installed, or after the Reset button is
pressed. The temperature will update after a few
seconds.
AM
4
TEMP
■ During time and day setting mode, the temperature
and program displays will go blank.
■ Example: Set the Thermostat to the current time of
2:16 pm on Saturday. Refer to the Steps below.
STEP 1:
STEP 2:
■ Press to enter time and day setting mode. The cur-
rent hour and the AM / PM indicator will be flashing.
M
day/time
day/time
AM
■ Press to change the Hour up or down to the
current hour.
Note the AM / PM indicator, as the display will
change at 12 AM and 12 PM.
■ Press again to change from hour setting to minute
setting. The current minute will be flashing.
M
PM
■ Press to change the Minute up or down to the
current minute.
15
STEP 3:
STEP 4:
■ Press again to change from minute setting to day
setting. The current day will be flashing.
M
day/time
PM
■ Press to change the Day up or down to the
current day.
SA
■ Press again to change back to the
normal display.
day/time
PM
or
2
hold
TEMP
/return
NOTE: You may press
normal display.
at any time during Day and Time setting to return to the
hold
/return
DAYLIGHT SAVING TIME
SA
SET TEMP
■ Press and hold.
day/time
AM
■ Press to enter Daylight Saving Time.
2
TEMP
or
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
16
PROGRAMMING
16
Setting Time and Day (continued)
12 HR. / 24 HR. TIME FORMAT
Minute, or Day is flashing to toggle between the 12
hour and 24 hour formats. The AM / PM indicator will
not be displayed in 24 hour mode. Both the current
time and all programs will automatically change to the
selected format.
Your thermostat is set from the factory in normal 12
(AM / PM) time format. To change to 24 hour (military)
program
time, press
at any time while the Hour,
Default Programs
Studies conducted by the Department of Energy esti-
mate that setting your thermostat back 10°F (6°C) for
two 8-hour periods during winter can reduce your fuel
bill by as much as 33%. By setting your thermostat up
5°F (3°C) for two 8-hour periods during summer you
can reduce your fuel bill up to 25%.
Your Hunter thermostat is pre-programmed to meet
the ENERGY STAR® guidelines for energy efficiency.
■ The thermostat is pre-programmed for all 7 days of the week as shown below.
Temperature in F° (C°)
Program Number
Time
6:00am
8:00am
4:00pm
10:00pm
Heat
Cool
1
2
3
4
68°F (20°C)
60°F (16°C)
68°F (20°C)
60°F (16°C)
78°F (26°C)
85°F (29°C)
78°F (26°C)
82°F (28°C)
■ Refer to Manual Programming on page 18 for instructions on entering or changing the programs.
17
Personal Program Schedule
17
Use a pencil so you can revise your records each time
you change your temperature settings.
Before programming or changing programs, use this
Personal Program Schedule to determine which times
and temperature settings will best satisfy both your
comfort and energy saving requirements.
Heating
Cooling
Day Prog. 1
Prog. 2
Time
Prog. 3
Prog. 4
Day Prog. 1
Prog. 2
Time
Prog. 3
Prog. 4
Mon. Time
Temp
Time
Time
Mon. Time
Temp
Time
Time
Temp
Temp
Temp
Temp
Temp
Temp
Tues.
Time
Time
Time
Time
Tues.
Time
Time
Time
Time
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Wed. Time
Temp
Time
Time
Time
Wed. Time
Temp
Time
Time
Time
Temp
Temp
Temp
Temp
Temp
Temp
Thurs. Time
Temp
Time
Time
Time
Thurs. Time
Temp
Time
Time
Time
Temp
Temp
Temp
Temp
Temp
Temp
Fri.
Time
Time
Time
Time
Fri.
Time
Time
Time
Time
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Sat.
Sun.
Time
Time
Time
Time
Sat.
Sun.
Time
Time
Time
Time
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Time
Time
Time
Time
Time
Time
Time
Time
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Temp
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
18
PROGRAMMING
18
Manual Programming
■ Your thermostat can be programmed for week-
days and weekends, or have unique programs for
all 7 days. Use Weekday/Weekend Programming
below or 7-day Programming on page 21 to enter
or revise programs to match your Personal Pro-
gram Schedule.
NOTE: 1) The program time can be set in 10
minute increments, and remains the
same for both Heat and Cool programs.
2) The program temperature can be set
in increments of 1°F (1°C).
3) After 15 seconds without a key press,
the thermostat will return to normal
display mode.
4) When setting the program time, note
the AM / PM indicator.
■ Familiarize yourself with Manual Programming, so
that you can easily modify your programs as your
comfort needs change. The example below dem-
onstrates how to program your thermostat.
5) With the Auto Recovery feature en-
abled, you do not need to set your
comfort program times early. Auto
Recovery will determine how early to
turn your system on, so that the room
is comfortable at the program time.
19
Weekday/Weekend Programming
system
heat
■ Slide System Selector Switch to HEAT or COOL to
program the corresponding system.
off
cool
NOTE: If the system selector is in the OFF position, no programming is
permitted. The LCD display will show only dashes when the program key is pressed.
STEP 1:
STEP 2:
■ Press to enter program mode. HEAT or COOL will
be displayed on the LCD.
M
T
W
TH
F
program
AM
1
HEAT
■ The Program hour and AM or PM indicator are
flashing. Press to change the hour.
STEP 3:
■ Press again to change to the minute position.
The current minute will be flashing.
M
T
W
TH
F
program
AM
■ Press to change the minute.
1
HEAT
(continued)
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
20
PROGRAMMING
20
Weekday/Weekend Programming (continued)
STEP 4:
■ Press again to change to the program temperature.
The current temperature will be flashing.
M
T
W
TH
F
program
AM
■ Press to change the temperature.
1
HEAT
STEP 5:
STEP 6:
■ Press again to move to the next program number.
program
prog day
■ Repeat steps 3 - 5 to change the remaining
weekday programs.
■ Press to change to weekend programs.
SA SU
AM
■ Repeat steps 3 - 5 to change the weekend programs.
1
■ Press to exit Program mode, or wait 15 seconds to
exit automatically.
hold
HEAT
/return
21
7-Day Programming
system
■ Slide System Selector Switch to HEAT or COOL to
program the corresponding system.
heat
off
cool
M
STEP 1
■ Press to enter program mode, display shows week-
day programs.
AM
AM
AM
program
prog day
1
■ Press 2 times to reach the Monday program.
HEAT
M
program
keys to set
Step 2
Step 3
■ Use
,
and
the 4 programs for Monday.
1
HEAT
■ Press to change to the next day’s programs.
T
prog day
■ Repeat Step 2 to complete the selected day’s programs.
■ Continue repeating Steps 2 and 3 to program all 7
days of the week.
1
HEAT
Step 4
Step 5
■ When finished press to return to normal mode.
hold
■ After 15 seconds, the thermostat will return to
normal mode automatically.
/return
■ Change the System Selector Switch to the other
system, and repeat Steps 1 through 4 above.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
22
PROGRAMMING
22
Reviewing Programs
You may want to review the programs to confirm that the settings are compatible with your lifestyle.
Weekday
Programs
■ Press to display M – F programs.
M
T
W
TH
F
program
AM
■ Press repeatedly to cycle through the 4 programs.
1
HEAT
Weekend
Programs
■ Press to display the Sa – Su programs.
SA SU
prog day
program
PM
3
■ Press repeatedly to cycle through the 4 programs.
HEAT
Daily
Programs
■ Press to display M – F programs.
NOTE: Time and Temperature display will be
blank when at least one weekday program
is different.
M
T
W
TH F
program
prog day
■ Press to change to Sa – Su. Again, if the display is
blank, one of the weekend programs is different.
23
Daily
Programs
(cont.)
■ Press again to change to Monday’s program.
■ Continue pressing to cycle through each day.
■ Press repeatedly to cycle through the 4 programs.
M
prog day
program
AM
1
HEAT
■ Press to return to normal mode.
hold
/return
■ After 15 seconds, the thermostat will return to nor-
mal mode automatically.
NOTE: Programs take affect as soon as the thermostat returns to normal mode.
If you are armchair programming the thermostat, slide the system selector to the OFF position before
mounting the thermostat to the wallplate.
Reviewing the Current Temperature Setting
■ Current time and temperature.
SA
PM
3
HEAT
TEMP
■ Press for 1 second or less.
SET TEMP
or
■ Set Temperature is shown above current room
temperature.
3
HEAT
TEMP
■ If held for over 1 second, Temporary Manual Over-
ride mode is entered. Refer to the next page.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
24
OPERATION
24
System Selector Switch
The System Selector switch on the front of the thermostat determines the operating
mode of the thermostat. You may select COOL, OFF, HEAT.
system
heat
off
NOTE: Anytime you install or remove the thermostat from the wallplate,
slide the System Selector to the OFF position to prevent the possibility
of a rapid system On-Off.
cool
Fan Switch
fan
The Fan switch should normally be located in the AUTO position. The Fan will be
turned on along with normal operation of your system. In a normal gas or oil furnace,
the Fan will be turned on by your furnace after its warm-up delay. For electric heat, air
conditioning, and heat pump operation, the Fan will turn on with the system.
auto
on
To run the Fan on continuously, slide the Fan switch to the ON position.
25
Temporary Manual Override
25
To temporarily change the current set temperature without affecting your program:
■ Press and hold for about 1 second to enter Manual
SET TEMP
Override mode. When display flashes, you can
release the key.
or
3
COOL
TEMP
■ Press again to change to your desired Set Tempera-
ture. Hold the key for 2 seconds to fast-advance the
Set Temperature.
or
■ Press to return to normal mode, or wait 5 seconds
for it to return automatically.
hold
/return
■ The current program number will flash to signify the
SA
Temporary Override.
PM
■ At the next program change time, the Temporary
Override is cancelled, and the next program tem-
perature becomes the setpoint temperature.
3
COOL
TEMP
To end the Temporary Manual Override:
■ Press and wait for HOLD to display on the LCD.
■ Press again. This will return the set temperature to the current program set temperature.
hold
/return
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
26
OPERATION
26
Permanent Manual Override
To hold your Manual Override for vacation or just an extended period of time:
■ Press to make the current program temperature the
hold
TH
HOLD temperature. HOLD will be displayed on the
/return
PM
LCD, and the Program number will disappear.
HOLD
■ Follow the Temporary Manual Override instructions
above to change the Permanent Manual Override
temperature.
TEMP
■ You can confirm the held set temperature by press-
ing for less than 1 second.
To end the Permanent Manual Override:
■ Press again. The thermostat will return to the current
program, and the HOLD display will be canceled.
hold
/return
27
Vacation Override (Programmable Hold)
This thermostat can hold a fixed temperature for a selected number of days (up to 30). After the selected number
of days, the thermostat will return to normal program operation. This feature allows you to return home to your
normal comfort setpoint temperatures.
■ Press and hold for 2 seconds. Display will change to
show a 1 day hold.
SET TEMP
hold
/return
HOLD
COOL
TEMP
■ Press to select the number of days to set the
vacation hold temperature. In this example,
14 is used.
SET TEMP
day/time
HOLD
COOL
TEMP
■ Press to set the desired temperature.
or
■ Press to return to normal mode, or wait 5 seconds
for it to return automatically.
hold
/return
■ HOLD will be shown on the LCD, and “VACA” will
alternate with the time.
HOLD
TEMP
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
28
OPERATION
28
Home Today
This Hunter patented feature allows you to quickly and temporarily override your energy saving program setting on
days when you are normally away from home with one key press.
home
■ Press to enter the Home Today override. The highest
program temperature for today will be selected from
your programs in Heat mode and become the set
temperature. (In Cool mode, Home Today will select
the lowest program temperature for today to be the
set temperature.)
F
AM
HOME TODAY
TEMP
HEAT
today
■ The display will flash “HOME TODAY” and the pro-
gram number will disappear.
■ When pressed during the first or second program of
the day, Home Today will automatically return to
program control at the start of the fourth program
of the day. If Home Today is pressed after the start of
the third program time of the day, the thermostat
will remain in Home Today mode until the first pro-
gram of the next day.
home
today
■ If Home Today is already active, you may similarly
extend it to the first program of the next day by
pressing the key again after the start time of the
third program.
29
■ If the system is changed between Heat and Cool modes during the “Home Today”
override period, the setpoint temperature will be automatically updated. It will auto-
matically change from the highest heat program setpoint to the lowest cool program
setpoint, or from the lowest cool program setpoint to the highest heat program setpoint.
■ Press to exit Home Today mode before the schedule ending time. “HOME TODAY”
is no longer displayed on the LCD screen, and the thermostat returns to the
current program.
hold
/return
■ You can manually change the setpoint temperature while in Home Today mode. Refer
to the Temporary Manual Override instructions on page 24. Manually changing the set
temperature while in Home Today mode will not affect the Home Today ending time.
However, the set temperature will not change automatically with a manual or Auto-
matic change between heating and cooling.
home
today
■ You may also press the HOME TODAY key while in Temporary Manual Override. The
operation is the same as the previous point above.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
30
OPERATION
30
Energy Monitor
The Energy monitor feature measures and stores the
amount of time the heating and air conditioning sys-
tem operates. Usage can be displayed for Today (since
12am), Yesterday, This Week (since Monday), Last
Week (last Monday through Sunday), and Total (up to
999 Hrs. 59 Min.). By monitoring your energy
usage, you see how much the set-back periods
are saving and you can test program adjustment
to save even more. Use table on page 17.
■ To review energy usage, press to cycle through To-
day, Yesterday, This Week, Last Week, and Total.
Press again to return to normal mode, or wait 15
seconds for the display to return to normal mode.
You can also return to normal mode at any time by
pressing RETURN.
Hr
energy
Min
Usage Today
■ For example: This LCD display shows Today’s usage
to be 10 Hours, 26 minutes.
■ Press and hold for 3 seconds to reset the Energy
Monitor’s counters. The display will blink, and all
counters will be cleared to zero.
energy
NOTE: Clearing the Energy Monitor counter will also clear the Filter Monitor counter, as Filter
usage and Total Energy usage are the same. Also, clearing the Filter Monitor counter will
clear ALL Energy Monitor counters as well.
31
Filter Monitor
31
Your thermostat also keeps a record of the number of hours your filter has been in use. To maximize your system’s
performance and energy efficiency, change or clean your filter regularly.
■ When the total system run time for heat and cool
W
reaches 400 hours, FILTER will flash on the LCD
display to remind you to clean or change your
PM
FILTER
system’s filter. FILTER will continue to flash until
2
the counter is set back to zero.
COOL
TEMP
■ Press to review total filter usage. The display will
blink FILTER ,then show the Filter Monitor counter.
After 15 seconds, the display will return to normal
mode, or you can hit RETURN to exit immediately.
The Filter Monitor will display up to 999 hours and
59 minutes of usage.
filter
In this example, the counter is at 410 Hours,
26 minutes.
Hr
FILTER
■ To reset the Filter Monitor counter, depress FILTER
for 3 seconds. The display will blink, and the counter
will be reset to zero.
Min
NOTE: Clearing the Filter Monitor counter will also clear ALL Energy Monitor counters, as Filter
usage and Total Energy usage are the same. Also, clearing the Energy Monitor counters will
clear the Filter Monitor counter as well.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
32
OPERATION
32
Auto Recovery
Hunter’s Auto Recovery feature meets the ENERGY
STAR® guidelines for energy efficiency by allowing the
heating or cooling system to recover gradually from an
energy-saving setpoint temperature to a comfort
setpoint temperature.
For example, in Heat mode, you could have the follow-
ing programs:
Program #4 (Overnight)
Set Temp = 60°F
Time = 10pm
Program #1 (Morning)
Set Temp = 68°F
Time = 6am
Auto Recovery calculates how early to turn your sys-
tem back On, so that the room temperature is already
comfortable by the start of the comfort temperature
program period. Auto Recovery works in both Heat
and Cool modes.
The room temperature fell to 60°F overnight. Rather
than having the thermostat turning on at 6am, Auto
Recovery would note the temperature difference be-
tween 60°F and 68°F and turn the Heat on approxi-
mately 30 minutes early. Therefore, the room tempera-
ture at 6am would be about 68°F instead of 60°F.
■ When the thermostat is in Auto Recovery mode, the display will
alternate RECO with time, and the program indicator will flash.
4
HEAT
TEMP
33
Details of Auto Recovery Operation:
33
■ Auto Recovery can be disabled by sliding the Re-
covery switch on the circuit board to the DISABLE
position. Refer to page 13.
■ Auto Recovery will be canceled and change to
Home Today mode if HOME TODAY is pressed
during the recovery process.
■ Auto Recovery will not operate if Permanent hold,
Temporary hold or Home Today is in operation.
■ Auto Recovery will be canceled and change to
Temporary Manual Override mode if the setpoint
is adjusted during the recovery process.
■ Auto Recovery can be canceled manually if HOLD/
RETURN is pressed during the recovery process. If a
recovery process is canceled manually then the re-
covery process will not start again until the next
program period starts (an exception is that if time
or program is changed then the thermostat will
check Auto Recovery conditions immediately).
■ If the system is changed between heat and cool
then the thermostat will recalculate Auto Recov-
ery again. Setpoint temperature will be changed
to the opposite system’s comfort temperature if
the recovery entry criteria are still met. Otherwise,
the recovery process will be canceled and return
to program control mode.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
34
OPERATION
34
SPAN Setting Mode
Your thermostat is set at the factory to cycle at
1˚F (0.5˚C) above and below the set temperature.
(Span = 2) This setting has been designed to pro-
vide a comfortable room temperature under most
all conditions. However, if you find your system
cycling too fast or too slow, then the Span can be
adjusted to modify the cycle time.
■ Press and hold BOTH for three seconds. The display
will flash, and SPAN will be displayed on the LCD.
■ Press to raise the Span to 3. This setting INCREASES
the cycle time by allowing your system to run
LONGER.
■ Press to lower the Span to 1. This setting
DECREASES the cycle time by causing your
system to run SHORTER.
The Span settings remain the same for both HEAT
and COOL.
When batteries are installed in the thermostat, or
the Reset key is pressed, the Span is reset back to
setting 2.
The Span can be changed at any time, and is inde-
pendent of program times or temperatures.
35
Backlighting (INDIGLO® night-light)
35
Your thermostat has an electroluminescent lamp that
backlights the display for easy viewing in the dark.
NOTE: If the thermostat is in Low Battery warn-
ing condition, the backlight will not operate. Re-
place with 2 new alkaline batteries to restore the
Backlight function.
When any key is pressed or the System Switch is
changed, the display is illuminated.
The display will remain illuminated for 5 seconds after
the last key is pressed. This allows the light to stay on
if you need to operate several keys.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
36
SAFETY FEATURES
36
Low Battery Warning
■ Your thermostat has a two-stage low battery warning system.
T
When the batteries are first detected to be weak, the first stage
low battery warning is indicated by battery symbol flashing on
the LCD display. At your earliest convenience, you need to replace
the batteries with 2 new AA alkaline batteries.
PM
3
HEAT
TEMP
■ When the batteries become too weak for normal operation, the
thermostat enters the second stage low battery warning which
shuts down the thermostat. In this condition, “BATT” flashes
alone on the display, and the thermostat will turn your system Off.
Your system will remain shut-off until the batteries are replaced.
NOTE: The thermostat will still keep the current time and your programs in memory until
new batteries are installed. After confirming that new batteries have been inserted, the
thermostat will return to normal operation.
37
Error Mode
37
■ If the thermostat is unable to control your system due to an unex-
pected battery problem, the thermostat will enter Error Mode. In
this condition, the thermostat flashes “Err” on the LCD display, and
shuts off your system. To correct this problem, replace the batteries
with 2 new AA alkaline batteries, even if you have recently replaced
them. Next, use a paper clip to press the RESET button next to the
keypad. You will need to reprogram your thermostat and confirm
normal operation.
■ If Error Mode returns, please call Hunter Technical support at
1-888-830-1326 for further information.
Auto Cut Off
Your thermostat will automatically cut-off in Heat
mode if the room temperature rises above 95˚F (35˚C).
It will cut-off in Cool mode if the room temperature
drops below 40˚F (4˚C).
NOTE: If your system has malfunctioned and no
longer responds to thermostat controls, the Auto
Cut-Off will have no effect.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
38
TROUBLESHOOTING
38
Problem
Solution
1. Remove clear mylar sticker.
Scrambled or Double Display
(numbers over numbers)
No Display
1. Check battery connections and batteries.
2. Press RESET button with a small pin and hold in for two seconds.
Entire Display Dims
1. Replace Batteries.
Program Does Not Change at
your Desired Setting
1. Check that the time is set properly to “AM” or “PM”.
2. Check that the thermostat is not in “HOLD” or “Home Today” modes.
3. Check for the correct day setting.
Auto / Fan Does Not turn On
1. Move HG/HE selector to opposite position
Heating or Cooling Does Not
Go On or Off
1. Check that the system selector switch is in the correct position
(“HEAT,” “COOL”).
2. There may be as much as a 4 minute delay before the Heat or Cool
system turns On - wait and check. (Compressor protection delay.)
3. Check your circuit breakers and switches to ensure there is power to
the system.
4. Replace batteries.
5. Make sure your furnace blower door is closed properly.
6. If your system only uses 4-wires, be sure the jumper wire is installed
between the RC and RH terminals.
7. Check the position of the Furnace or Heat Pump selector switch: STD - HP.
39
Problem (cont.)
Solution (cont.)
39
Erratic Display
1. Press the RESET button once with a small pin and hold for two
seconds. The thermostat will need to be re-programmed.
If unit continues to operate in
the Off position
1. Replace unit.
1. Replace unit.
Thermostat permanently reads
“HI,” “LO,” or “ERR-” after
pressing reset button
If you experience any other problems, call 888-830-1326 from 8 AM to 5 PM Central Time for technical assistance.
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
40
WIRING DIAGRAM
40
4-wire Heat/Cool System
System
Selector
Wallplate
Terminals
Jumper
–
STD HP
Rh
Y/O
W/B
G
Rc
Y1
X
X
Heat/Cool
24V Supply
Heat Relay
or Valve
Cool
Fan
Contactor
Relay
5-wire Heat/Cool System
System
Selector
Wallplate
Terminals
No Jumper
–
STD HP
Rh
Y/O
W/B
G
Rc
Y1
X
Fan
Heat Relay
or Valve
Cool 24V
Supply
Heat 24V
Supply
Cool
Relay
Contactor
X - No Connection
41
Single-stage Heat Pump
41
System
Selector
Wallplate
Terminals
Jumper
–
STD HP
Y1
G
Rc
Rh
Y/O
W/B
Heat
Mode
Cool
Mode
OR
X
Fan
Heat Pump
24V Supply
Reversing
Valve
Compressor
Contactor
Relay
Connect to Proper Reversing
Valve Terminal. See Table A
2-wire Heat Only
System
Selector
Wallplate
Terminals
Jumper
–
STD HP
Rh
Y/O
W/B
G
Rc
Y1
X
X
X
X
Heat 24V or
Heat Relay
or Valve
Millivolt Supply
X - No Connection
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
42
WIRING DIAGRAM
42
3-wire Heat Only
System
Selector
Wallplate
Terminals
Jumper
–
STD HP
Rh
Y/O
W/B
G
Rc
Y1
X
X
X
Heat 24V
Supply
Heat Relay
or Valve
Fan
Relay
3-wire Cool Only
System
Selector
Wallplate
Terminals
Jumper
–
STD HP
Rh
Y/O
W/B
G
Rc
Y1
X
X
X
Fan
Cool 24V
Supply
Cool
Contactor
Relay
X - No Connection
43
Ask Your Local Retailer for
Other Quality Products from Hunter
Fans
Air Purifiers
Humidifiers
To locate our nearest Hunter Dealer, call 1-800-4HUNTER,
Download from Www.Somanuals.com. All Manuals Search And Download.
41644_model44360_web.pmd
44
Hunter Fan Company
2500 FRISCO AVENUE
MEMPHIS, TN 38114
®
© 2003, Hunter Fan Company Form No. 41644-01, 8/03