Set & $ave
Programmable Thermostat
installation and
operation manual
Model
44155c
Form# 42708-01
20091111
©2009 Hunter Fan Co.
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Important Information....................................... 5
Tools ................................................................ 6
Uninstalling the Existing Unit ........................... 7
Installing the Thermostat ............................... 12
installing the wall plate ................................ 12
connecting the wires ................................... 16
attaching the thermostat ............................. 18
Settings ......................................................... 22
Methods of Operation ................................... 26
manual operation ........................................ 28
default programs ......................................... 32
creating custom programs .......................... 34
Icons and Features ....................................... 38
Troubleshooting ............................................ 49
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Set & Save
Programmable Thermostat
l
Model 44155C
Congratulations!
Thank you for choosing a Hunter programmable
thermostat. Your new Hunter thermostat will
provide years of reliable service and year-round
energy savings.
Please read this manual before beginning
installation and save this booklet for complete
operation instructions.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
iMporTanT inforMaTion
This thermostat is designed to work on the following
heating and cooling systems:
Gas – Standing Pilot
Gas – Electronic Ignition
Gas – Fired Boilers
Gas – Milivolt Systems
Oil – Fired Boilers
Oil – Fired Furnace
Electric Furnace
Electric Air Conditioning
Single Stage Heat Pump - No auxilary
This thermostat is not designed for multi-stage heat
pump systems or 110/220 V baseboard heating
systems.
If you are unsure what kind of heating and cooling
system you have, please contact a qualified HVAC
Technician for assistance.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
ToolS
This thermostat includes two #8 slotted screws
and two wall anchors for mounting.
To install your new thermostat, you will need the
following supplies:
Flat-head screwdriver
....................................................................................
Small Phillips-head screwdriver
....................................................................................
Hammer
....................................................................................
Electric drill and 3/16” bit
....................................................................................
Two 1.5 Volt (AA) size alkaline batteries
....................................................................................
6
Download from Www.Somanuals.com. All Manuals Search And Download.
noTiCE! Do not disconnect the
wires from the existing thermostat
before reading these instructions.
The wires must be labeled prior
to removal to ensure proper
reconnection.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
uninSTalling ThE ExiSTing uniT
1. Turn the system power OFF from the existing
thermostat. Turn the power to the HVAC
system OFF at the main power panel or at
the furnace.
2. Remove the existing thermostat cover to
access the wires from the wall.
(Some thermostats may have multiple covers, screws
or other locking devices that must be removed or
disengaged.)
3. Locate, but do not disconnect the wires.
(If wires are not visible, they may be connected to the
back of the wall plate. Some models may have doors
that open to expose the wires and mounting screws.)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
if your existing
thermostat is marked...
label the wire
with this sticker:
RH / R / VR / 4
R H
24 Volt
RH
R C
RC / VC
24 Volt cool
RC
Y/0
Y / 0
air conditioning
compressor
Y / C* / M / O
W / B
W / H / B
G / F
heating
fan
W/B
G
G
Y 1
heat pump
compressor
Y1
Y1
10
Download from Www.Somanuals.com. All Manuals Search And Download.
uninSTalling ThE ExiSTing uniT, ConT.
4. Using the provided stickers, label each wire
according to the chart.
(If the terminals are not labeled, contact
a qualified HVAC technician.)
note: Wire colors do not always comply
with standards, so wire color should be
ignored. refer to the existing terminal
designation for proper identification.
*If wires marked Y & C are both present, C may
be a Common wire and should not be used. If
you have a wire marked C, do not connect it
to any terminal. This wire is used only for non-
battery powered thermostats.
5. Do not let the wires slip back into the
wall during disconnection. You may want
to secure the wires to the wall as you
disconnect them. After all wires are labeled,
disconnect each wire and remove the
existing wall plate.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
inSTalling ThE ThErMoSTaT
inSTalling ThE Wall plaTE
1. Remove the wall plate from the new
thermostat by pressing the release tab on the
bottom of the thermostat.
2. Position the new wall plate on the wall and
pull the labeled wires through the opening.
3. If the existing holes do not match those
on the Hunter wall plate, or if there are no
existing holes, visually level the wall plate
and mark the wall for two holes.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
inSTalling ThE ThErMoSTaT, ConT.
4. Remove the wall plate and drill two 3/16”
holes where marked.
5. Tap the plastic anchors into the holes until
they are flush with the wall.
6. Reposition the wall plate on the wall, pulling
the wires through the opening. Insert the
mounting screws through the wall plate and
into the anchors. Verify that the wall plate
is visually level and securely tighten both
screws.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Y1
Y/0
W/B
RCRH
G
Terminal Shield
16
Download from Www.Somanuals.com. All Manuals Search And Download.
inSTalling ThE ThErMoSTaT, ConT.
ConnECTing ThE WirES
1. Loosen, but do not remove, the terminal
screws.
note: a jumper wire has been provided,
Jumper
connecting the rC and rh terminals for
systems that do not provide both an rh
G
RC RH
and rC wire. if you have both an rh and rC
wire, remove this jumper. if you do not have
both an rh and rC wire, leave the jumper in
place.
2. Match and connect the wires from the wall
to the terminals as shown. Wires should be
inserted behind the black terminal shields.
Tighten each screw after the connection has
been made.
(The ends of any extra wires should be wrapped in
electrical tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the
wall to prevent interference.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Thermostat
Cover
T
AM
4
HEA
T
ENABLE
RECOVERY
DISABLE
System
Switch
STD
HP
SYSTEM TYPE
HG
HE
FAN OPTION
Y1
G
RWC/B YR/HO YR/HO WR/CB YG1
18
Download from Www.Somanuals.com. All Manuals Search And Download.
inSTalling ThE ThErMoSTaT, ConT.
aTTaChing ThE ThErMoSTaT
Lift the thermostat cover and set the SYSTEM switch to OFF
and the FAN switch to AUTO.
1. Locate the HE/HG switch on the back of the thermostat.
Set the switch to HG (default) for gas furnace and oil
burners. Set the switch to HE for electric furnaces.
(The switch has no effect when the system is set to
cooling mode.)
2. Locate the Auto Recovery switch on the back of the
thermostat. If you wish to use the Auto Recovery
feature, verify that the switch is in the ENABLE position.
If you do not wish to use this feature, simply change the
switch to the DISABLE position. See pages 44-45 for
more information.
3. System type - Locate the SyStem type switch on the
back of the thermostat. Select either STD (Standard) or
HP (Heat Pump) to match your system.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Tab
2
20
Download from Www.Somanuals.com. All Manuals Search And Download.
inSTalling ThE ThErMoSTaT, ConT.
4. Place the top of the thermostat over the two
tabs on the wall plate. Press the thermostat
onto the wall plate and press to snap the
bottom tab into place.
note: Do not force the thermostat onto the wall plate,
as the terminal pins may be damaged. if the thermostat
does not snap into place properly, the unit may not
work.
5. Insert two AA alkaline batteries.
6. Restore power at the electrical panel or
furnace.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
reset
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTingS
The default setting of the thermostat is
Fahrenheit (Fo).
noTiCE: Changing ThiS SETTing Will rESET ThE
ThErMoSTaT To faCTorY DEfaulT prograMS.
(If no button is pressed for 5 seconds, the unit will
return to the Normal Display mode.)
To change to Celcius (Co):
1. Press and hold the Up button.
2. Use a paperclip to press the Reset button.
3. Continue to press the Up button, but release
the Reset button when the LCD turns on.
To reset the unit to Fo, press only the Reset
button.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
AM
PM
day/time
24
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTingS, ConT.
The default for this thermostat setting is in a
12 hour format. You can change the format to
24 hour format by pressing Day/Time and then
Program.
The aM/pM indicator will be off when the thermostat is
in 24 hour mode.
Setting day and time:
1. Press Day/Time. (AM/PM and current hour will
flash)
2. Press Up or Down to adjust the setting.
3. Press Day/Time again to adjust the minute
setting.
4. Press Day/Time again to adjust the day of the
week.
5. Press Day/Time to return to the normal display.
You may also press hold/return at any time to return
to the normal display.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
T
AM
4
HEAT
26
Download from Www.Somanuals.com. All Manuals Search And Download.
METhoDS of opEraTion
This thermostat gives you the ability to program
up to 4 custom temperature settings per day or
utilize pre-programmed settings.
For manual operation instructions, see pages
28-31.
To utilize the pre-programmed settings, see
pages 32-33.
To create custom programs, see pages 34-37.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
H
AMT
2
HEAT
28
Download from Www.Somanuals.com. All Manuals Search And Download.
METhoDS of opEraTion, ConT.
1. Manual opEraTion
Many people prefer to operate their thermostats
manually, adjusting settings as needed. You
can either temporarily override the settings for
the current program, or permanently override all
settings and adjust temperatures manually.
If you want to only override the current program:
1. Press and hold Up or Down for one second to
enter Manual Override mode. (Release the button
when the display flashes.)
2. Press the Up or Down buttons to adjust the
temperature setting as desired.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
HOLD
system
heat
cool
off
hold
/return
30
Download from Www.Somanuals.com. All Manuals Search And Download.
METhoDS of opEraTion, ConT.
Manual opEraTion, ConT.
If you want to permanently override all settings
and adjust the thermostat manually:
1. Press Hold/Return until the Hold icon appears.
2. Press and hold Up or Down for one second to
enter Manual Override mode. (Release the button
when the display flashes.)
3. Press the Up or Down buttons to adjust the
temperature setting as desired.
4. Press and release Hold/Return to return to the
normal display.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
DEfaulT prograMS CharT
10 pm
Program 4
o
o
Heat : 60 F (16 C)
o
o
Cool : 82 F (28 C)
Program 3
o
o
Heat : 68 F (20 C)
o
o
Cool : 78 F (26 C)
6 am
Program 1
o
o
Heat : 68 F (20 C)
o
o
Cool : 78 F (26 C)
4 pm
8 am
Program 2
o
o
Heat : 60 F (16 C)
o
o
Cool : 85 F (29 C)
32
Download from Www.Somanuals.com. All Manuals Search And Download.
METhoDS of opEraTion, ConT.
By using the pre-programmed settings, this
thermostat can save you money by optimizing
energy usage in heating and cooling.
After setting the time and temperature scale,
no additional action is needed to utilize the pre-
programmed settings.
Refer to the Default Programs Chart for detailed
information about the pre-programmed settings.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
AM
PM
system
heat
cool
program
off
hold
/return
34
Download from Www.Somanuals.com. All Manuals Search And Download.
METhoDS of opEraTion, ConT.
3. CrEaTing CuSToM prograMS
• Program times can be set in 10 minute
increments.
• Program temperature can be set in
increments of 1o F (1o C).
• After 15 seconds of inactivity during
programming, the thermostat will return to
Normal Display mode.
• When setting the program time, note the AM/
PM indicator.
• Press Hold/Return at any time to exit Program
mode.
1. Slide the system switch to HEAT or COOL to
program the corresponding system.
2. Press Program to enter Program mode. (The
LCD will begin to flash)
35
Download from Www.Somanuals.com. All Manuals Search And Download.
M
T
W
F
SA SU
AMTH
PM
1
2
3
4
HEAT COOL
system
heat
cool
program
off
hold
/return
36
Download from Www.Somanuals.com. All Manuals Search And Download.
METhoDS of opEraTion, ConT.
3. Press Up or Down to change the hour. Press
Program to save the hour and adjust the
minute setting.
4. Press Up or Down to change the minute. Press
Program to save the minute setting and adjust
the temperature.
5. Press Up or Down to set the temperature.
Press Program again to move to the next
program number.
(There are 4 programs per day. If you do not wish to
assign all 4 programs per day set at least 2, keeping in
mind that the total program time must equal 24 hours.)
6. Repeat steps 2-5 for the remaining days.
7. To review your program settings, press
Program repeatedly to review the customized
programs.
(You can make changes at any time when the
thermostat is in Program mode.)
8. Slide the system selector switch to the opposite
position and repeat steps 2-5.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
FILTER
filter
38
Download from Www.Somanuals.com. All Manuals Search And Download.
iConS anD fEaTurES
1. INDIGLO® Night-Light - will backlight the
display for easy viewing in the dark. Press
any button to illuminate the light.
(If no button is pressed after 5 seconds, the backlight
will turn off.)
note: if the thermostat shows a low Battery Warning,
the backlight will not operate. follow the instructions
on pages 42-43 to change batteries.
2. Filter change indicator - will flash after 400
hours of system use as a reminder to check
or change your filter. Press and hold the Filter
button for 3 seconds after changing the filter
to reset the filter timer.
(Pressing the Filter button for less than 3 seconds will
cause the Filter change indicator icon to appear. The
filter timer will not be affected unless the button is held
for more than 3 seconds.)
39
Download from Www.Somanuals.com. All Manuals Search And Download.
HEAT COOL
system
heat
cool
off
reset
40
Download from Www.Somanuals.com. All Manuals Search And Download.
iConS anD fEaTurES, ConT.
3. Span setting mode – allows you to adjust
the system ON/OFF cycle rate. The default
setting is 2 (the system cycles ON or OFF
when the temperature is within 1o F (0.5o C)
above and below the set temperature.) The
span setting can be adjusted if your system is
cycling too fast or too slowly.
Press and hold both the Up and Down buttons
until the word SPAN appears. Use the Up or
Down button to adjust the span setting.
(Up will increase your cycle time by allowing the system
to run longer; Down will decrease your cycle time by
causing the system to run for a shorter length of time.)
Span settings remain the same for HEAT and
COOL system settings. When batteries are
installed, or the unit is RESET, the span cycle
will revert to 2.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
M
PM
4
COOL
STAGE 1
STAGE 2
42
Download from Www.Somanuals.com. All Manuals Search And Download.
iConS anD fEaTurES, ConT.
4. Low battery warning – indicates two stages of
battery power shortage.
When the batteries are detected as weak, the
icon will flash until new AA alkaline batteries
are installed. If the batteries become too
weak for normal operation, the thermostat
enters the second battery power shortage
mode.
When insufficient battery power is left, the battery icon
will flash alone on the display and your system will
turn off. The system will remain off until new batteries
are installed. after removing the batteries, program
and time settings will remain in memory for one
minute. if all battery power is lost, programs and time
settings will be erased.
The thermostat will resume normal operation
after new batteries are installed.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
hold
/return
44
Download from Www.Somanuals.com. All Manuals Search And Download.
iConS anD fEaTurES, ConT.
5. Auto recovery – allows heating and cooling
systems to gradually recover from an
energy-saving setpoint temperature to a
comfort setpoint temperature. Auto recovery
calculates the time needed to adjust the
temperature to the next program setting.
When the thermostat is in Auto Recovery
mode, the display will flash alternating
messages of RECO and the time. Auto
Recovery can be disabled by sliding the
recovery switch on the back of the circuit
board to the disable position.
(Auto Recovery will not operate if Permanent or
Temporary holds are on.)
Press Hold/Return during the Auto Recovery
process to manually cancel the recovery.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
46
Download from Www.Somanuals.com. All Manuals Search And Download.
iConS anD fEaTurES, ConT.
6. Error mode – indicates an unexpected
battery problem. The screen will flash an
ERR message and shut your system off
until the batteries are replaced with new
AA alkaline batteries. You must Reset and
reprogram the thermostat after replacing the
batteries if the thermostat has entered Error
mode.
7. Auto cut off – automatically turns the system
off if the temperature rises above 95o F (35o
C) or drops below 40o F (4o C).
(If your HVAC system has malfunctioned, the system
will no longer respond to thermostat controls and the
Auto cut off will have no effect.)
47
Download from Www.Somanuals.com. All Manuals Search And Download.
1. Temperature range
o
o
o
99
F
o
(35 C)
30
F
o
(0 C)
45
F
95
F
o
(37 C)
o
o
(7 C)
Out of Range
O"utHof RIan"ge
Program Range
Display Range
"LO"
o
o
<
>
99
30
F
F
2. Compressor protection
After the system stops running
in cooling mode, there will be a
3.5 minute delay before it can be
restarted to prevent compressor
damage due to rapid cycling.
3.
reset
resetting the unit
To restore the thermostat to the
original factory settings, press the
reset button with a paperclip.
(This will erase any user-programs.)
48
Download from Www.Somanuals.com. All Manuals Search And Download.
TrouBlEShooTing
1. My display will not come on.
1 a. Check batteries and battery connections.
1 b. Reset the thermostat.
...................................................................................
2. The auto fan feature will not operate properly.
2 a. Remove the thermostat from the wall plate and set the
HG/HE switch to the correct position.
..............................................................................
3. My display is erratic.
3 a. Reset the thermostat and reprogram your settings.
....................................................................................
4. The program will not change at my desired
setting.
4 a. Check that the time is set properly to AM or PM.
4 b. Make sure the thermostat is not in permanent override
mode.
4 c. Check that the day setting is correct.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
TrouBlEShooTing
5. My heating or cooling will not turn on or off.
5 a. Check the Heat/Cool function switch to ensure it is set to
the desired position.
5 b. Wait. There may be as much as a 4-minute delay before
the system turns on or off to protect the compressor.
5 c. Check the circuit breakers and switches to ensure there
is enough power to the system.
5 d. Replace the batteries.
5 e. If applicable, make sure the furnace blower door is
closed properly.
5 f. If your system has 4 wires, ensure the jumper wire is
installed between the RC and RH terminals.
....................................................................................
6. The display will come on, but it will not stay
illuminated.
6 a. Replace batteries.
50
Download from Www.Somanuals.com. All Manuals Search And Download.
TrouBlEShooTing
7. My system continues to operate when the
thermostat is in the off position.
7 a. Replace unit.
....................................................................................
8. The LCD screen permanently reads HI, LO,
or ERR.
8 a. Replace unit.
....................................................................................
9. How do I just operate my thermostat
manually?
9 a. Manual operation instructions are on pages 28-31.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
Is there help on the web?
....................................................................................
Can’t I just call someone?
Sure. Our Technical Support Group is available from 8 am
to 5 pm CST. They may be reached toll-free at 1-888-830-
1326.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
|