Hunter Fan Thermostat 43154 User Manual

PROGRAMMABLE  
THERMOSTAT  
M
AM  
4
TEMP  
Owners Manual  
Model 43154  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
Wire Labeling (Continued)  
After labeling wires, disconnect them from the existing thermostat terminals.  
Remove existing wallplate. To make sure wires do not fall back into wall opening, you may  
want to tape them to the wall.  
If hole in wall is larger than necessary for wires, seal this hole with insulating material so that  
no hot or cold air can enter the back of the thermostat from the wall. This air could cause a  
false thermostat reading.  
RH  
x
RC  
x
G
x
x
Y/O  
Table A  
NOTE: Do not connect a “Common” wire (sometimes labeled “C”) to any terminal on  
this thermostat. Tape up the wire and do not use. This wire provides electricity to non-  
battery powered thermostats.  
Mount Wallplate and Thermostat  
Remove the wallplate from your thermostat by pressing the release tab on the bottom of the  
thermostat. See Figure 2.  
4
4-wire Heat/Cool System  
System  
Selector  
Wallplate  
Terminals  
Jumper  
STD HP  
Rh  
Y/O  
W/B  
G
Rc  
Y1  
X
X
Heat/Cool  
24V Supply  
Heat Relay  
or Valve  
Cool  
Fan  
Relay  
Contactor  
System  
Selector  
Wallplate  
Terminals  
No Jumper  
STD HP  
Rh  
Y/O  
W/B  
G
Rc  
Y1  
X
Fan  
Relay  
Heat Relay  
or Valve  
Cool 24V  
Supply  
Heat 24V  
Supply  
Cool  
Contactor  
System  
Selector  
Jumper  
Cool  
Mode  
OR  
Heat  
Mode  
X
Connect to Proper Reversing  
Valve Terminal. See Table A  
(Continued)  
5
Setting Day and Time (Continued)  
Cooling  
Day  
Program 1  
Time  
Temp  
Program 2  
Time  
Program 3  
Time  
Program 4  
Time  
STEP 2:  
Monday –  
Friday  
Press again to change from hour setting to  
minute setting. The current minute will be  
flashing.  
M
day/time  
Temp  
Temp  
Temp  
PM  
Saturday – Time  
Sunday Temp  
Time  
Time  
Time  
Press to change the Minute up or down to  
the current minute.  
Temp  
Temp  
Temp  
STEP 3:  
Revising Programs  
Press again to change from minute setting  
to day setting. The current day will be flash-  
ing.  
M
Familiarize yourself with manually changing programs, so that you can easily modify the  
programs as your comfort needs change. Follow the steps below to change the program times  
and temperatures.  
day/time  
PM  
NOTE: 1) The program time can be set in 10-minute increments.  
Press to change the Day up or down to the  
2) The program temperature can be set in increments of 1˚F (1˚C).  
current day.  
3) After 15 seconds without a key press, the thermostat will return  
to normal display mode.  
STEP 4:  
4) When setting the program time, note the AM / PM indicator.  
SA  
Press again to change back to the  
normal display.  
day/time  
STEP 1:  
PM  
2
or  
system  
Slide the System Switch to the HEAT or  
COOL position to program the correspond-  
ing system.  
SA  
heat  
hold  
off  
TEMP  
cool  
/return  
PM  
2
hold  
NOTE: If the System Switch is in the OFF  
position, the last position used will be  
programmed.  
NOTE: You may press  
the normal display.  
at any time during Day and Time setting to return to  
TEMP  
/return  
STEP 2:  
12 Hr. / 24 Hr. Time Format  
Press to enter program mode. HEAT or COOL  
will be displayed on the LCD.  
Your thermostat is set from the factory in normal 12 (AM / PM) time format. To change to 24  
M T W TH F  
AM  
program  
program  
hour (military) time, press  
at any time while the Hour, Minute, or Day is flashing to  
toggle between the 12 hour and 24 hour formats. The AM / PM indicator will not be displayed in  
24 hour mode. Both the current time and all programs will automatically change to the selected  
format.  
1
STEP 3:  
HEAT  
The Program hour and AM or PM indicator  
are flashing. Press to change the hour.  
PROGRAMMING  
The following time and temperature settings are pre-programmed into the thermostat:  
STEP 4:  
Temperature in C˚ (F˚)  
Press again to change to the minute posi-  
tion. The current minute will be flashing.  
M T W TH F  
AM  
program  
Program Number  
Time  
6:00 am  
8:00 am  
4:00 pm  
10:00 pm  
Heat  
Cool  
Press to change the minute.  
1
1
2
3
4
68˚F (20˚C)  
60˚F (16˚C)  
68˚F (20˚C)  
60˚F (16˚C)  
78˚F (26˚C)  
85˚F (29˚C)  
78˚F (26˚C)  
82˚F (28˚C)  
HEAT  
STEP 5:  
Press again to change to the program tem-  
perature. The current temperature will be  
flashing.  
M T W TH F  
AM  
program  
All 7 days of the week have the same default programs.  
Press to change the temperature.  
1
HEAT  
Personal Program Schedule  
You can revise the factory programs to match your own schedule. Use this Personal Program  
Schedule to determine which times and temperature settings match your comfort and energy  
saving requirements. Use a pencil so you can revise your records each time you change your  
program settings.  
STEP 6:  
Press again to move to the next program number.  
program  
Repeat Steps 3 through 5 to change the remaining Weekday and  
Weekend programs. (There are a total of 8 programs.)  
Heating  
Day  
Program 1  
Time  
Temp  
Program 2  
Time  
Program 3  
Time  
Program 4  
Time  
Monday –  
Friday  
After cycling through all 8 programs, press again to return the  
display to normal.  
program  
Temp  
Temp  
Temp  
Saturday – Time  
Sunday Temp  
Time  
Time  
Time  
Press at any time to exit the Program Mode.  
hold  
Temp  
Temp  
Temp  
/return  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
Reviewing Programs  
Filter Change Indicator  
Your thermostat measures the number of hours your heating and cooling system has been in  
use. To maximize your system’s performance and energy efficiency, change or clean your filter  
regularly.  
program  
To review your program settings, press  
repeatedly to cycle through the programs.  
You can also make changes at any time.  
When the total system runtime for heat and  
M T W TH F SA SU SET TEMP  
cool reaches 400 hours, the Filter Change  
Indicator will flash as a reminder to check  
your system’s filter.  
System Selector Switch  
AM  
PM  
The System Selector switch on the front of the thermostat  
determines the operating mode of the thermostat. You may  
select COOL, OFF, HEAT.  
system  
heat  
FILTER  
2
After changing or cleaning the system’s  
COOL TEMP  
off  
filter  
filter, press and hold the Filter Key for 3  
seconds. The display will blink, and the timer  
will be reset to zero.  
cool  
NOTE: Anytime you install or remove the thermostat  
from the wallplate, slide the System Selector to the  
OFF position to prevent the possibility of a rapid sys-  
tem On-Off.  
Note: Pressing the Filter Key at any time for less than 3 seconds will cause the Filter  
indicator to appear on the LCD. This is only to confirm key operation, and the timer is  
not affected unless the key is held for greater than 3 seconds.  
Fan Switch  
The Fan switch should normally be located in the AUTO posi-  
tion. The Fan will be turned on along with normal operation of  
your system. In a normal gas or oil furnace, the Fan will be  
turned on by your furnace after its warm-up delay. For electric  
heat, air conditioning, and heat pump operation, the Fan will  
turn on with the system.  
fan  
SPAN Setting Mode  
auto  
on  
Your thermostat is set at the factory to cycle at 1˚F (0.5˚C) above and below the set temperature.  
(Span = 2) This setting has been designed to provide a comfortable room temperature under  
most all conditions. However, if you find your system cycling too fast or too slow, then the Span  
can be adjusted to modify the cycle time.  
To run the Fan on continuously, slide the Fan switch to the ON position.  
Press and hold BOTH for three seconds. The  
display will flash, and SPAN will be dis-  
played on the LCD.  
Temporary Manual Override  
To temporarily change the current set temperature without affecting your program:  
Press to raise the Span to 3. This setting  
INCREASES the cycle time by allowing your  
system to run LONGER.  
Press and hold for about 1 second  
to enter Manual Override mode. When  
SET TEMP  
or  
display flashes, you can release the key.  
Press to lower the Span to 1. This setting  
DECREASES the cycle time by causing your  
system to run SHORTER.  
3
Press again to change to your desired Set  
Temperature. Hold the key for 2 seconds to  
fast-advance the Set Temperature.  
COOL TEMP  
or  
The Span settings remain the same for both HEAT and COOL.  
The Span can be changed at any time, and is independent of program times  
or temperatures.  
Press to return to normal mode, or wait 5  
seconds for it to return automatically.  
When batteries are installed in the thermostat, or the Reset key is pressed, the Span is reset back  
to setting 2.  
hold  
/return  
The current program number will flash to  
signify the Temporary Override.  
SA  
®
Backlighting (INDIGLO Night-Light)  
Your thermostat has an electroluminescent lamp that backlights the display for easy viewing in  
the dark.  
PM  
At the next program change time, the Tem-  
porary Override is cancelled, and the next  
program temperature becomes the setpoint  
temperature.  
3
When any key is pressed or the System Switch is changed, the display is illuminated.  
COOL TEMP  
The display will remain illuminated for 5 seconds after the last key is pressed. This allows the  
light to stay on if you need to operate several keys.  
To end the Temporary Manual Override:  
Note: If the thermostat is in Low Battery warning condition, the backlight will not  
operate. Replace with 2 new alkaline batteries to restore the Backlight function.  
Press, then press again. This will return the set temperature to the current  
hold  
program set temperature.  
/return  
Low Battery Warning  
Your thermostat has a two-stage low battery warning  
system. When the batteries are first detected to be weak,  
T
Permanent Override  
To hold your Manual Override for vacation or just an extended period of time:  
the first stage low battery warning is indicated by battery  
symbol flashing on the LCD display. At your earliest conve-  
nience, you need to replace the batteries with 2 new AA  
alkaline batteries.  
PM  
Press to make the current program tem-  
3
TH  
hold  
perature the HOLD temperature. HOLD  
will be displayed on the LCD, and the  
Program number  
HEAT  
TEMP  
/return  
PM  
When the batteries become too weak for normal operation,  
the thermostat enters the second stage low battery warning  
which shuts down the thermostat. In this condition, “BATT”  
flashes alone on the display, and the thermostat will turn  
your system Off. Your system will remain shut-off until the  
batteries are replaced.  
HOLD  
will disappear.  
TEMP  
Follow the Temporary Manual Override  
instructions above to change the Permanent  
Manual Override temperature.  
You can confirm the held set temperature by  
pressing for less than 1 second.  
Note: The thermostat will still keep the current time and your programs in memory until  
new batteries are installed. After confirming that new batteries have been inserted, the  
thermostat will return to normal operation.  
To end the Permanent Manual Override:  
Press again. The thermostat will return to the current program, and the HOLD  
display will be canceled.  
hold  
/return  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Auto Recovery  
TROUBLESHOOTING  
Climate Technology’s Auto Recovery feature meets the ENERGY STAR® guidelines for energy  
efficiency by allowing the heating or cooling system to recover gradually from an energy-  
saving setpoint temperature to a comfort setpoint temperature.  
Problem  
Solution  
No Display  
1. Check battery connections and batteries.  
Auto Recovery calculates how early to turn your system back On, so that the room tempera-  
ture is already comfortable by the start of the comfort temperature program period. Auto  
Recovery works in both Heat and Cool modes.  
2. Press RESET button with a small pin and hold in  
for two seconds.  
When the thermostat is in Auto Recovery mode, the dis-  
play will alternate “RECO” with time, and the program  
indicator will flash.  
Entire Display Dims  
1. Replace Batteries  
Auto Recovery can be disabled by sliding the Recovery  
switch on the circuit board to disable.  
Program Does Not Change  
at your Desired Setting  
1. Check that the time is set properly to AM” or “PM”.  
2
HEAT TEMP  
2. Check that the thermostat is not in Permanent  
HOLD mode.  
Auto Recovery will not operate if Permanent hold or  
Temporary hold is in operation.  
3. Check for the correct day setting.  
Auto Recovery can be canceled manually if  
HOLD / RETURN is pressed during the recovery  
process.  
Auto Fan Does Not  
Turn On Properly  
1. Move HG/HE selector to correct position.  
Auto Recovery will be canceled and change to Temporary  
Manual Override mode if the setpoint is adjusted during  
the recovery process.  
Heating or Cooling Does  
Not Go On or Off  
1. Check that the function switch is in the correct  
position (“HEAT” or “COOL).  
2. There may be as much as 4-minute delay before  
the system turns On – wait and check. (Compressor  
protection delay.)  
Error Mode  
If the thermostat is unable to control your system due to an  
unexpected battery problem, the thermostat will enter Error  
Mode. In this condition, the thermostat flashes “Err” on the  
LCD display, and shuts off your system. To correct this prob-  
lem, replace the batteries with 2 new AA alkaline batteries,  
even if you have recently replaced them. Next, use a paper  
clip to press the RESET button next to the keypad. You will  
need to reprogram your thermostat and confirm normal  
operation.  
3. Check your circuit breakers and switches to ensure  
there is power to the system.  
4. Replace batteries.  
5. Make sure your furnace blower door is closed properly.  
6. If your non-heat pump system only uses 4-wires, be  
sure the jumper wire is installed between the RC and  
RH terminals.  
If Error Mode returns, please call Climate Technology Technical support at 1-800-676-7861 for  
further information.  
7. Check the position of the System Selector switch:  
Standard or Heat Pump.  
Auto Cut Off  
Erratic Display  
1. Press the reset button once with a small pin and hold  
for two seconds. Then reprogram.  
Your thermostat will automatically cut-off in Heat mode if the room temperature rises above  
95˚F (35˚C). It will cut-off in Cool mode if the room temperature drops below 40˚F (4˚C).  
Note that if your system has malfunctioned and no longer responds to thermostat controls,  
the Auto Cut-Off will have no effect.  
If unit continues to operate  
in the Off position  
1. Replace unit.  
1. Replace unit.  
Mechanical Heat Back-Up  
Thermostat permanently  
reads “HI”, “LO”, or “ERR”  
This thermostat includes a bi-metal switch that will automatically turn on the Heat when the  
temperature reaches about 41° F (5°C).  
WARNING: This switch only activates the Heating terminal (W). The sys-  
tem itself must be capable of automatically turning the Fan On. Without  
normal Fan operation, severe damage to the heating system could result.  
If you experience any other problems, call 1-800-676-7861 from 8 AM to 5 PM Central Time for  
technical assistance.  
Climate Technology Corp.  
2500 FRISCO AVENUE  
MEMPHIS, TN 38114  
© 2003 Climate Technolgoy Corp.  
41639-01 07/02/2003  
A Hunter Fan company  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grindmaster Coffeemaker AM 344 04 User Manual
Haier Flat Panel Television L1509A A User Manual
Hamilton Beach Range 32507S User Manual
Harbor Freight Tools Automobile Accessories 69623 User Manual
Honeywell Clock TE211W User Manual
Hotpoint Dishwasher FDUD4212 User Manual
HP Hewlett Packard Network Card HP NC150T User Manual
Husqvarna Lawn Mower ZTH User Manual
Hypertec Carrying Case 3510 User Manual
Hypertec Mouse CMROPROBLHY User Manual