Hunter Fan Thermostat 42711 01 User Manual

Set & $ave  
Programmable  
Thermostat  
installation and  
operation manual  
Model  
44260  
Form# 42711-01  
20091118  
©2009 Hunter Fan Co.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
Important Information .......................................5  
Tools  
6
Uninstalling the Existing Unit............................7  
Installing the Thermostat ................................12  
installing the wall plate ................................ 12  
connecting the wires ................................... 16  
attaching the thermostat ............................. 18  
Settings...........................................................22  
Methods of Operation.....................................26  
manual operation ........................................ 28  
default programs ......................................... 32  
creating custom programs .......................... 34  
Icons and Features.........................................38  
Wiring .............................................................49  
Troubleshooting..............................................52  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
Set & Save  
Programmable Thermostat  
l
Model 44260  
Congratulations!  
Thank you for choosing a Hunter programmable  
thermostat. Your new Hunter thermostat will  
provide years of reliable service and year-round  
energy savings.  
Please read this manual before beginning  
installation and save this booklet for complete  
operation instructions.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
iMporTanT inforMaTion  
This thermostat is designed to work on the following  
heating and cooling systems:  
Gas – Standing Pilot  
Gas – Electronic Ignition  
Gas – Fired Boilers  
Gas – Milivolt Systems  
Oil – Fired Boilers  
Oil – Fired Furnace  
Electric Furnace  
Electric Air Conditioning  
Single Stage Heat Pump - No auxilary  
This thermostat is not designed for multi-stage heat  
pump systems or 110/220 V baseboard heating  
systems.  
If you are unsure what kind of heating and cooling  
system you have, please contact a qualified HVAC  
Technician for assistance.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
ToolS  
This thermostat includes two #8 slotted screws  
and two wall anchors for mounting.  
To install your new thermostat, you will need the  
following supplies:  
Flat-head screwdriver  
....................................................................................  
Small Phillips-head screwdriver  
....................................................................................  
Hammer  
....................................................................................  
Electric drill and 3/16” bit  
....................................................................................  
Two 1.5 Volt (AA) size alkaline batteries  
....................................................................................  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
noTiCE! Do not disconnect the  
wires from the existing thermostat  
before reading these instructions.  
The wires must be labeled prior  
to removal to ensure proper  
reconnection.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
uninSTalling ThE ExiSTing uniT  
1. Turn the system power OFF from the existing  
thermostat. Turn the power to the HVAC  
system OFF at the main power panel or at  
the furnace.  
2. Remove the existing thermostat cover to  
access the wires from the wall.  
(Some thermostats may have multiple covers, screws  
or other locking devices that must be removed or  
disengaged.)  
3. Locate, but do not disconnect the wires.  
(If wires are not visible, they may be connected to the  
back of the wall plate. Some models may have doors  
that open to expose the wires and mounting screws.)  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
if your existing thermostat is  
marked...  
label the wire with this  
sticker:  
RH / R / VR / 4  
R H  
24 Volt  
RH  
R C  
RC / VC  
24 Volt cool  
RC  
Y / 0  
air conditioning compressor  
Y / C* / M / O  
Y/0  
W / B  
W / H / B  
G / F  
heating  
W/B  
G
fan  
G
heat pump compressor  
Y 1  
Y1  
Y1  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
uninSTalling ThE ExiSTing uniT, ConT.  
4. Using the provided stickers, label each wire  
according to the chart.  
(If the terminals are not labeled, contact  
a qualified HVAC technician.)  
note: Wire colors do not always comply  
with standards, so wire color should be  
ignored. refer to the existing terminal  
designation for proper identification.  
*If wires marked Y & C are both present, C may  
be a Common wire and should not be used. If  
you have a wire marked C, do not connect it  
to any terminal. This wire is used only for non-  
battery powered thermostats.  
5. Do not let the wires slip back into the  
wall during disconnection. You may want  
to secure the wires to the wall as you  
disconnect them. After all wires are labeled,  
disconnect each wire and remove the  
existing wall plate.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
inSTalling ThE ThErMoSTaT  
inSTalling ThE Wall plaTE  
1. Remove the wall plate from the new  
thermostat by pressing the release tab on the  
bottom of the thermostat.  
2. Position the new wall plate on the wall and  
pull the labeled wires through the opening.  
3. If the existing holes do not match those  
on the Hunter wall plate, or if there are no  
existing holes, visually level the wall plate  
and mark the wall for two holes.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
inSTalling ThE ThErMoSTaT, ConT.  
4. Remove the wall plate and drill two 3/16”  
holes where marked.  
5. Tap the plastic anchors into the holes until  
they are flush with the wall.  
6. Reposition the wall plate on the wall, pulling  
the wires through the opening. Insert the  
mounting screws through the wall plate and  
into the anchors. Verify that the wall plate  
is visually level and securely tighten both  
screws.  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
RCRH  
Y1  
G
Y/0  
W/B  
Terminal Shield  
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
inSTalling ThE ThErMoSTaT, ConT.  
ConnECTing ThE WirES  
1. Loosen, but do not remove, the terminal  
screws.  
note: a jumper wire has been provided,  
connecting the rC and rh terminals for  
systems that do not provide both an rh  
and rC wire. if you have both an rh and rC  
wire, remove this jumper. if you do not have  
both an rh and rC wire, leave the jumper in  
Jumper  
G
RC RH  
place.  
2. Match and connect the wires from the wall  
to the terminals as shown. Wires should be  
inserted behind the black terminal shields.  
Tighten each screw after the connection has  
been made.  
(The ends of any extra wires should be wrapped in  
electrical tape and carefully pushed back into the wall.)  
3. Push any excess wire length back into the  
wall to prevent interference.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Thermostat Cover  
T
AM  
4
HEA  
T
ENABLE  
RECOVERY  
DISABLE  
System  
Switch  
HP  
STD  
SYSTEM  
TYPE  
HG  
HE  
RC RH Y/O W/B Y1  
RC G  
G
FAN OPTION  
18  
Download from Www.Somanuals.com. All Manuals Search And Download.  
inSTalling ThE ThErMoSTaT, ConT.  
aTTaChing ThE ThErMoSTaT  
Lift the thermostat cover and set the SYSTEM switch to OFF  
and the FAN switch to AUTO.  
1. Locate the HE/HG switch on the back of the thermostat.  
Set the switch to HG (default) for gas furnace and oil  
burners. Set the switch to HE for electric furnaces.  
(The switch has no effect when the system is set to  
cooling mode.)  
2. Locate the Auto Recovery switch on the back of the  
thermostat. If you wish to use the Auto Recovery  
feature, verify that the switch is in the ENABLE position.  
If you do not wish to use this feature, simply change the  
switch to the DISABLE position. See pages 44-45 for  
more information.  
3. System type - Locate the SyStem type switch on the  
back of the thermostat. Select either STD (Standard) or  
HP (Heat Pump) to match your system.  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
Tab  
2
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
inSTalling ThE ThErMoSTaT, ConT.  
4. Place the top of the thermostat over the two  
tabs on the wall plate. Press the thermostat  
onto the wall plate and press to snap the  
bottom tab into place.  
note: Do not force the thermostat onto the wall plate,  
as the terminal pins may be damaged. if the thermostat  
does not snap into place properly, the unit may not  
work.  
5. Insert two AA alkaline batteries.  
6. Restore power at the electrical panel or  
furnace.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
reset  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETTingS  
The default setting of the thermostat is  
Fahrenheit (Fo).  
noTiCE: Changing ThiS SETTing Will rESET ThE  
ThErMoSTaT To faCTorY DEfaulT prograMS.  
(If no button is pressed for 5 seconds, the unit will  
return to the Normal Display mode.)  
To change to Celcius (Co):  
1. Press and hold the Up button.  
2. Use a paperclip to press the Reset button.  
3. Continue to press the Up button, but release  
the Reset button when the LCD turns on.  
To reset the unit to Fo, press only the Reset  
button.  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM  
PM  
day/time  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SETTingS, ConT.  
The default for this thermostat setting is in a  
12 hour format. You can change the format to  
24 hour format by pressing Day/Time and then  
Program.  
The aM/pM indicator will be off when the thermostat is  
in 24 hour mode.  
Setting day and time:  
1. Press Day/Time. (AM/PM and current hour will  
flash)  
2. Press Up or Down to adjust the setting.  
3. Press Day/Time again to adjust the minute  
setting.  
4. Press Day/Time again to adjust the day of the  
week.  
5. Press Day/Time to return to the normal display.  
You may also press hold/return at any time to return  
to the normal display.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
T
AM  
4
HEAT  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
METhoDS of opEraTion  
This thermostat gives you the ability to program  
up to 4 custom temperature settings per day or  
utilize pre-programmed settings.  
For manual operation instructions, see pages  
28-31.  
To utilize the pre-programmed settings, see  
pages 32-33.  
To create custom programs, see pages 34-37.  
27  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TH  
AM  
2
HEAT  
28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
METhoDS of opEraTion, ConT.  
1. Manual opEraTion  
Many people prefer to operate their thermostats  
manually, adjusting settings as needed. You  
can either temporarily override the settings for  
the current program, or permanently override all  
settings and adjust temperatures manually.  
If you want to only override the current program:  
1. Press and hold Up or Down for one second to  
enter Manual Override mode. (Release the button  
when the display flashes.)  
2. Press the Up or Down buttons to adjust the  
temperature setting as desired.  
29  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HOLD  
system  
heat  
cool  
off  
hold  
/return  
30  
Download from Www.Somanuals.com. All Manuals Search And Download.  
METhoDS of opEraTion, ConT.  
Manual opEraTion, ConT.  
If you want to permanently override all settings  
and adjust the thermostat manually:  
1. Press Hold/Return until the Hold icon appears.  
2. Press and hold Up or Down for one second to  
enter Manual Override mode. (Release the button  
when the display flashes.)  
3. Press the Up or Down buttons to adjust the  
temperature setting as desired.  
4. Press and release Hold/Return to return to the  
normal display.  
31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEfaulT prograMS CharT  
10 pm  
Program 4  
o
o
Heat : 60 F (16 C)  
o
o
Cool : 82 F (28 C)  
Program 3  
o
o
Heat : 68 F (20 C)  
o
o
Cool : 78 F (26 C)  
6 am  
Program 1  
o
o
Heat : 68 F (20 C)  
o
o
Cool : 78 F (26 C)  
4 pm  
8 am  
Program 2  
o
o
Heat : 60 F (16 C)  
o
o
Cool : 85 F (29 C)  
32  
Download from Www.Somanuals.com. All Manuals Search And Download.  
METhoDS of opEraTion, ConT.  
2. DEfaulT prograMS  
By using the pre-programmed settings, this  
thermostat can save you money by optimizing  
energy usage in heating and cooling.  
After setting the time and temperature scale,  
no additional action is needed to utilize the pre-  
programmed settings.  
Refer to the Default Programs Chart for detailed  
information about the pre-programmed settings.  
33  
Download from Www.Somanuals.com. All Manuals Search And Download.  
AM  
PM  
system  
heat  
cool  
program  
off  
hold  
/return  
34  
Download from Www.Somanuals.com. All Manuals Search And Download.  
METhoDS of opEraTion, ConT.  
3. CrEaTing CuSToM prograMS  
• Program times can be set in 10 minute  
increments.  
• Program temperature can be set in  
increments of 1o F (1o C).  
• After 15 seconds of inactivity during  
programming, the thermostat will return to  
Normal Display mode.  
• When setting the program time, note the AM/  
PM indicator.  
• Press Hold/Return at any time to exit Program  
mode.  
1. Slide the system switch to HEAT or COOL to  
program the corresponding system.  
2. Press Program to enter Program mode. (The  
LCD will begin to flash)  
35  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M
T
W
TH  
F
SA SU  
AM  
PM  
1
2
3
4
HEAT COOL  
system  
heat  
cool  
program  
off  
hold  
/return  
36  
Download from Www.Somanuals.com. All Manuals Search And Download.  
METhoDS of opEraTion, ConT.  
3. Press Up or Down to change the hour. Press  
Program to save the hour and adjust the  
minute setting.  
4. Press Up or Down to change the minute. Press  
Program to save the minute setting and adjust  
the temperature.  
5. Press Up or Down to set the temperature.  
Press Program again to move to the next  
program number.  
(There are 4 programs per day. If you do not wish to  
assign all 4 programs per day set at least 2, keeping in  
mind that the total program time must equal 24 hours.)  
6. Repeat steps 2-5 for the remaining days.  
7. To review your program settings, press  
Program repeatedly to review the customized  
programs.  
(You can make changes at any time when the  
thermostat is in Program mode.)  
8. Slide the system selector switch to the opposite  
position and repeat steps 2-5.  
37  
Download from Www.Somanuals.com. All Manuals Search And Download.  
FILTER  
filter  
38  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iConS anD fEaTurES  
1. INDIGLO® Night-Light - will backlight the  
display for easy viewing in the dark. Press  
any button to illuminate the light.  
(If no button is pressed after 5 seconds, the backlight  
will turn off.)  
note: if the thermostat shows a low Battery Warning,  
the backlight will not operate. follow the instructions  
on pages 42-43 to change batteries.  
2. Filter change indicator - will flash after 400  
hours of system use as a reminder to check  
or change your filter. Press and hold the Filter  
button for 3 seconds after changing the filter  
to reset the filter timer.  
(Pressing the Filter button for less than 3 seconds will  
cause the Filter change indicator icon to appear. The  
filter timer will not be affected unless the button is held  
for more than 3 seconds.)  
39  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HEAT COOL  
system  
heat  
cool  
off  
reset  
40  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iConS anD fEaTurES, ConT.  
3. Span setting mode – allows you to adjust  
the system ON/OFF cycle rate. The default  
setting is 2 (the system cycles ON or OFF  
when the temperature is within 1o F (0.5o C)  
above and below the set temperature.) The  
span setting can be adjusted if your system is  
cycling too fast or too slowly.  
Press and hold both the Up and Down buttons  
until the word SPAN appears. Use the Up or  
Down button to adjust the span setting.  
(Up will increase your cycle time by allowing the system  
to run longer; Down will decrease your cycle time by  
causing the system to run for a shorter length of time.)  
Span settings remain the same for HEAT and  
COOL system settings. When batteries are  
installed, or the unit is RESET, the span cycle  
will revert to 2.  
41  
Download from Www.Somanuals.com. All Manuals Search And Download.  
M
PM  
4
COOL  
STAGE 1  
STAGE 2  
42  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iConS anD fEaTurES, ConT.  
4. Low battery warning – indicates two stages of  
battery power shortage.  
When the batteries are detected as weak, the  
icon will flash until new AA alkaline batteries  
are installed. If the batteries become too  
weak for normal operation, the thermostat  
enters the second battery power shortage  
mode.  
When insufficient battery power is left, the battery icon  
will flash alone on the display and your system will  
turn off. The system will remain off until new batteries  
are installed. after removing the batteries, program  
and time settings will remain in memory for one  
minute. if all battery power is lost, programs and time  
settings will be erased.  
The thermostat will resume normal operation  
after new batteries are installed.  
43  
Download from Www.Somanuals.com. All Manuals Search And Download.  
hold  
/return  
44  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iConS anD fEaTurES, ConT.  
5. Auto recovery – allows heating and cooling  
systems to gradually recover from an  
energy-saving setpoint temperature to a  
comfort setpoint temperature. Auto recovery  
calculates the time needed to adjust the  
temperature to the next program setting.  
When the thermostat is in Auto Recovery  
mode, the display will flash alternating  
messages of RECO and the time. Auto  
Recovery can be disabled by sliding the  
recovery switch on the back of the circuit  
board to the disable position.  
(Auto Recovery will not operate if Permanent or  
Temporary holds are on.)  
Press Hold/Return during the Auto Recovery  
process to manually cancel the recovery.  
45  
Download from Www.Somanuals.com. All Manuals Search And Download.  
46  
Download from Www.Somanuals.com. All Manuals Search And Download.  
iConS anD fEaTurES, ConT.  
6. Error mode – indicates an unexpected  
battery problem. The screen will flash an  
ERR message and shut your system off  
until the batteries are replaced with new  
AA alkaline batteries. You must Reset and  
reprogram the thermostat after replacing the  
batteries if the thermostat has entered Error  
mode.  
7. Auto cut off – automatically turns the system  
off if the temperature rises above 95o F (35o  
C) or drops below 40o F (4o C).  
(If your HVAC system has malfunctioned, the system  
will no longer respond to thermostat controls and the  
Auto cut off will have no effect.)  
47  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1. Temperature range  
o
o
o
99  
F
o
(35 C)  
30  
F
o
(0 C)  
45  
F
95  
F
o
(37 C)  
o
o
(7 C)  
Out of Range  
O"utHof RIan"ge  
Program Range  
Display Range  
"LO"  
o
o
<
>
99  
30  
F
F
2. Compressor protection  
After the system stops running  
in cooling mode, there will be a  
3.5 minute delay before it can be  
restarted to prevent compressor  
damage due to rapid cycling.  
3.  
reset  
resetting the unit  
To restore the thermostat to the  
original factory settings, press the  
reset button with a paperclip.  
(This will erase any user-programs.)  
48  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring  
49  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring, ConT.  
50  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Wiring, ConT.  
51  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TrouBlEShooTing  
1. My display will not come on.  
1 a. Check batteries and battery connections.  
1 b. Reset the thermostat.  
...................................................................................  
2. The auto fan feature will not operate properly.  
2 a. Remove the thermostat from the wall plate and set the  
HG/HE switch to the correct position.  
..............................................................................  
3. My display is erratic.  
3 a. Reset the thermostat and reprogram your settings.  
....................................................................................  
4. The program will not change at my desired  
setting.  
4 a. Check that the time is set properly to AM or PM.  
4 b. Make sure the thermostat is not in permanent override  
mode.  
4 c. Check that the day setting is correct.  
52  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TrouBlEShooTing  
5. My heating or cooling will not turn on or off.  
5 a. Check the Heat/Cool function switch to ensure it is set to  
the desired position.  
5 b. Wait. There may be as much as a 4-minute delay before  
the system turns on or off to protect the compressor.  
5 c. Check the circuit breakers and switches to ensure there  
is enough power to the system.  
5 d. Replace the batteries.  
5 e. If applicable, make sure the furnace blower door is  
closed properly.  
5 f. If your system has 4 wires, ensure the jumper wire is  
installed between the RC and RH terminals.  
....................................................................................  
6. The display will come on, but it will not stay  
illuminated.  
6 a. Replace batteries.  
53  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TrouBlEShooTing  
7. My system continues to operate when the  
thermostat is in the off position.  
7 a. Replace unit.  
....................................................................................  
8. The LCD screen permanently reads HI, LO,  
or ERR.  
8 a. Replace unit.  
....................................................................................  
9. How do I just operate my thermostat  
manually?  
9 a. Manual operation instructions are on pages 28-31.  
54  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Is there help on the web?  
....................................................................................  
Can’t I just call someone?  
Sure. Our Technical Support Group is available from 8 am  
to 5 pm CST. They may be reached toll-free at 1-888-830-  
1326.  
55  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Haan Vacuum Cleaner SI 70 User Manual
Heath Zenith Home Security System SL 7001 User Manual
Hotpoint Oven OS 897D P IX HP User Manual
HP Hewlett Packard Personal Computer 6 PC User Manual
HP Hewlett Packard Photo Printer Z3200ps User Manual
Hudson Sales Engineering All in One Printer DC 545 User Manual
Hyundai IT DVD Player H CMD7078 User Manual
IBM Cordless Telephone 412 User Manual
IBM Personal Computer 8172 User Manual
IBM TV Mount 92P1989 User Manual