Set & $ave
Programmable
Thermostat
Installation and
Operation Manual
Model
44360
Form# 42710-01
20091204
©2009 Hunter Fan Co.
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
Important Information .............................................................................. 5
Tools........................................................................................................ 6
Uninstalling the Existing Unit................................................................... 7
Installing the Thermostat ....................................................................... 12
Installing the Wall Plate.................................................................. 12
Connecting the Wires..................................................................... 16
Attaching the Thermostat ............................................................... 18
Settings.................................................................................................. 22
Methods of Operation............................................................................ 26
Manual Operation / Override.......................................................... 28
Default Programs ........................................................................... 32
Creating Custom Progams............................................................. 34
Icons and Features................................................................................ 38
Important Features................................................................................ 52
Troubleshooting..................................................................................... 53
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Set & Save
Programmable Thermostat
Model 44360
Congratulations!
Thank you for choosing a Hunter programmable thermostat. Your
new Hunter thermostat will provide years of reliable service and
year-round energy savings.
Please read this manual before beginning installation and save this
booklet for complete operation instructions.
The Hunter Technical Support Group is available from 7 am to 7 pm Monday
- Friday and 8:00 to 5:00 Saturdays CST. They may be reached toll-free at
1-888-830-1326.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPOrTAnT InFOrMATIOn
This thermostat is designed to work on the following
heating and cooling systems:
Gas – Standing Pilot
Gas – Electronic Ignition
Gas – Fired Boilers
Gas – Millivolt Systems
Oil – Fired Boilers
Oil – Fired Furnace
Electric Furnace
Electric Air Conditioning
Single-Stage Heat Pumps
This thermostat is not designed for multi-stage heat pump systems
or 110/220 V baseboard heating systems.
If you are unsure what kind of heating and cooling system you
have, please contact a qualified HVAC Technician for assistance.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
TOOlS
This thermostat includes two #8 slotted screws and two wall
anchors for mounting.
To install your new thermostat, you will need the following supplies:
Flat-head screwdriver
.............................................................................................
Small Phillips-head screwdriver
.............................................................................................
Hammer
.............................................................................................
Electric drill and 3/16” bit
.............................................................................................
Two 1.5 Volt (AA) size alkaline batteries
.............................................................................................
6
Download from Www.Somanuals.com. All Manuals Search And Download.
w
nOTICE! Do not disconnect the wires from the existing
thermostat before reading these instructions. The wires
must be labeled prior to removal to ensure proper
reconnection.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
UnInSTAllInG THE ExISTInG UnIT
1. Turn the system power OFF from the existing thermostat. Turn
the power to the HVAC system OFF at the main power panel or
at the furnace.
(Failure to turn off the power to the existing thermostat before
removal could damage your system.)
2. remove the existing thermostat cover to access the wires from
the wall.
(Some thermostats may have multiple covers, screws or other
locking devices that must be removed or disengaged. See page
8 for common examples.)
3. locate, but do not disconnect the wires.
(If wires are not visible, they may be connected to the back
of the wall plate. Some models may have doors that open to
expose the wires and mounting screws.)
9
Download from Www.Somanuals.com. All Manuals Search And Download.
WIrE lABElS
if your existing thermostat
is marked...
label the wire with
this sticker:
R H
RH / R / VR / 4
24 Volt
RH
R C
RC / VC
24 Volt cool
RC
Y / 0
air conditioning
compressor
Y / C* / M / O
Y/0
W / B
W / H / B
G / F
heating
fan
W/B
G
G
heat pump compressor
Y 1
Y1
Y1
10
Download from Www.Somanuals.com. All Manuals Search And Download.
UnInSTAllInG THE ExISTInG UnIT, COnT.
4. Using the provided stickers, label each wire according to the
Wire labels chart. (If the terminals are not labeled,
contact a qualified HVAC technician.)
Note: Wire colors do not always comply with standards, so
wire color should be ignored. refer to the existing terminal
designation for proper identification.
*If wires marked Y & C are both present, C may be a
Common wire and should not be used. If you have a wire
marked C, do not connect it to any terminal. This wire is used only
for non-battery powered thermostats.
5. Do not let the wires slip back into the wall during disconnection.
You may want to secure the wires to the wall as you disconnect
them. After all wires are labeled, disconnect each wire and
remove the existing wall plate.
(Any unused wires should be capped with an approved electrical connector,
such as electrical tape.)
11
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
InSTAllInG THE THErMOSTAT
InSTAllInG THE WAll PlATE
1. remove the wall plate from the new thermostat by pressing the
release tab on the bottom of the thermostat.
2. Position the new wall plate on the wall and pull the labeled wires
through the opening.
3. If the existing holes do not match those on the Hunter wall plate,
or if there are no existing holes, visually level the wall plate and
mark the wall for two holes.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
InSTAllInG THE THErMOSTAT, COnT.
4. remove the wall plate and drill two 3/16” holes where marked.
5. Tap the plastic anchors into the holes until they are flush with the
wall. (Do not use plastic anchors if you encounter a stud in the
wall.)
6. reposition the wall plate on the wall, pulling the wires through
the opening. Insert the mounting screws through the wall plate
and into the anchors. Verify that the wall plate is visually level
and securely tighten both screws.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
RC RH
G
Y/0
W/B Y1
Terminal Shield
16
Download from Www.Somanuals.com. All Manuals Search And Download.
InSTAllInG THE THErMOSTAT, COnT.
COnnECTInG THE WIrES
1. loosen, but do not remove, the terminal screws.
Jumper
note: A jumper wire has been provided, connecting the
rC and rH terminals for systems that do not provide both
an rH and rC wire. If you have both an rH and rC wire,
remove this jumper. If you do not have both an rH and rC
wire, leave the jumper in place.
G
RC RH
2. Match and connect the wires from the wall to the
terminals as shown. Wires should be inserted behind the black
terminal shields. Tighten each screw after the connection has
been made.
(The ends of any extra wires should be individually wrapped in electrical
tape and carefully pushed back into the wall.)
3. Push any excess wire length back into the wall to prevent
interference.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Thermostat
Cover
T
AM
ENABLE
RECOVERY
DISABLE
4
HEAT
System
Switch
HP
STD
Fan
SYSTEM TYPE
Switch
HG
HE
FAN OPTION
Y1
W/B Y/O RH RC
G
18
Download from Www.Somanuals.com. All Manuals Search And Download.
InSTAllInG THE THErMOSTAT, COnT.
ATTACHInG THE THErMOSTAT
lift the thermostat cover and set the SYSTEM switch to OFF and
the FAN switch to AUTO.
1. Fan option - locate the HE/HG switch on the back of the
thermostat. Set the switch to HG (default) for gas furnace and oil
burners. Set the switch to HE for electric furnaces. (The switch
has no effect when the system is set to cooling mode.)
2. recovery - locate the AUTO REcOvERY switch on the back of the
thermostat. If you wish to use the Auto recovery feature, verify
that the switch is in the EnABlE position. If you do not wish
to use this feature, simply change the switch to the DISABlE
position. See pages 44-45 for more information.
3. System type - locate the SYSTEM TYpE switch on the
back of the thermostat. Select either STD (Standard) or HP
(Heat Pump) to match your system.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
1
front cover
Tab
2
20
Download from Www.Somanuals.com. All Manuals Search And Download.
InSTAllInG THE THErMOSTAT, COnT.
4. Place the top of the thermostat over the two tabs on the wall
plate. Press the thermostat onto the wall plate and press to snap
the bottom tab into place.
note: Do not force the thermostat onto the wall plate, as the terminal
pins may be damaged. If the thermostat does not snap into place
properly, the unit may not work.
5. lift the front cover and insert two AA alkaline batteries.
6. restore power at the electrical panel or furnace.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
reset
22
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTInGS
o
The default setting of the thermostat is Fahrenheit (F ).
(nOTICE: CHAnGInG THIS SETTInG WIll rESET THE
THErMOSTAT TO FACTOrY DEFAUlT PrOGrAMS.)
o
To change to Celsius (C ):
1. Press and hold the Up button.
2. Use a paperclip to press the RESET button.
3. Continue to press the Up button, but release the reset button
when the lCD turns on.
To reset the unit to F, press only the RESET button.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
AM
PM
program
day/time
24
Download from Www.Somanuals.com. All Manuals Search And Download.
SETTInGS, COnT.
The default for this thermostat setting is in a 12 hour format. You
can change the format to 24 hour format by pressing DAY/TiME and
then pROGRAM.
The AM/PM indicator will be off when the thermostat is in 24 hour
mode.
Setting day and time:
1. Press DAY/TiME. (AM/PM and current hour will flash)
Press Up or DOwN to adjust the setting.
2. Press DAY/TiME again to adjust the minute setting.
Press Up or DOwN to adjust the setting.
3. Press DAY/TiME again to adjust the day of the week.
Press Up or DOwN to adjust the setting.
4. Press DAY/TiME to return to the normal display.
Press Up or DOwN to adjust the setting.
You may also press Hold/return at any time to return to the normal
display.
25
Download from Www.Somanuals.com. All Manuals Search And Download.
T
AM
4
HEAT
26
Download from Www.Somanuals.com. All Manuals Search And Download.
METHODS OF OPErATIOn
This thermostat gives you the ability to program up to 4 custom
temperature settings per day or utilize pre-programmed settings.
For manual operation / override instructions, see pages 28-35.
To utilize the pre-programmed settings, see pages 36-37.
To create custom programs, see pages 38-41.
27
Download from Www.Somanuals.com. All Manuals Search And Download.
TH
AM
2
HEAT
28
Download from Www.Somanuals.com. All Manuals Search And Download.
METHODS OF OPErATIOn (COnT.)
1. MAnUAl OPErATIOn / OVErrIDE
Many people prefer to operate their thermostats manually, adjusting
settings as needed. You can either temporarily override the settings
for the current program, or permanently override all settings and
adjust temperatures manually.
If you want to only override the current program:
1. Press and hold Up or DOwN for one second to enter Manual
Override mode. (Release the button when the display flashes.)
2. Press the Up or DOwN buttons to adjust the temperature setting
as desired.
The system will revert back to the program at the next scheduled
program time.
29
Download from Www.Somanuals.com. All Manuals Search And Download.
HOLD
system
heat
cool
off
hold
/return
30
Download from Www.Somanuals.com. All Manuals Search And Download.
METHODS OF OPErATIOn
2. PErMAnEnT OVErrIDE
If you want to permanently override all settings and adjust the
thermostat manually:
1. Press HOlD/RETURN until the Hold icon appears.
2. Press and hold Up or DOwN for one second to enter Manual
Override mode. (Release the button when the display flashes.)
3. Press the Up or DOwN buttons to adjust the temperature setting
as desired.
4. Press and release HOlD/RETURN to return to the normal display.
31
Download from Www.Somanuals.com. All Manuals Search And Download.
HOME TODAY
32
Download from Www.Somanuals.com. All Manuals Search And Download.
METHODS OF OPErATIOn
3. HOME TODAY OVErrIDE
Overrides the programmed settings during a time you would not
normally be home.
Pressing Home Today during the first or second programs of the
day will override the programs until the fourth program begins.
The thermostat will then go back into normal mode.
Pressing Home Today during the third program of the day will
override the programs until the first program of the next day.
Press HOME TODAY to enter or exit the program override. The
"Home Today" message will flash on the screen and the program
number will disappear. The highest or lowest schedule of the
program will appear for you to adjust. Press Up or DOwN to
adjust the temperature.
33
Download from Www.Somanuals.com. All Manuals Search And Download.
Set Temp
34
Download from Www.Somanuals.com. All Manuals Search And Download.
METHODS OF OPErATIOn
4. VACATIOn OVErrIDE
Overrides the programmed settings for a set amount of days.
The first number in Vacation Override mode indicates the number
of days you wish to hold the temperature for, and the temperature
beside it indicates the temperate you want to be held during
those days.The first day you set the Vacation Override feature will
be counted as day one in your number of days. The thermostat
will resume your normal programs during program four, the last
day of the override.
Press and hold the hold button until your time changes to a
number with a temperature beside it. Use day/time to adjust how
many days to override the temperature, and the up/down arrows
to set the temperature it should hold. During Vacation Override
the VACA will cycle with the time.
35
Download from Www.Somanuals.com. All Manuals Search And Download.
DEFAUlT PrOGrAMS CHArT
10 pm
Program 4
o
o
Heat : 60 F (16 C)
o
o
Cool : 82 F (28 C)
Program 3
o
o
Heat : 68 F (20 C)
o
o
Cool : 78 F (26 C)
6 am
Program 1
o
o
Heat : 68 F (20 C)
o
o
Cool : 78 F (26 C)
4 pm
8 am
Program 2
o
o
Heat : 60 F (16 C)
o
o
Cool : 85 F (29 C)
36
Download from Www.Somanuals.com. All Manuals Search And Download.
5. DEFAUlT PrOGrAMS
By using the pre-programmed settings, this thermostat can save
you money by optimizing energy usage in heating and cooling.
refer to the Default Programs Chart for detailed information about
the pre-programmed settings.
37
Download from Www.Somanuals.com. All Manuals Search And Download.
AM
PM
system
heat
program
off
cool
hold
/return
38
Download from Www.Somanuals.com. All Manuals Search And Download.
METHODS OF OPErATIOn
6. CrEATInG CUSTOM PrOGrAMS
•
•
•
Program times can be set in 10 minute increments.
o
o
Program temperature can be set in increments of 1 F (1 C).
After 15 seconds of inactivity during programming, the
thermostat will return to normal Display mode.
When setting each program time, note the AM/PM indicator.
Press HOlD/RETURN at any time to exit Program mode and save
your settings.
•
•
•
During normal operation, if no button is pressed for 5 seconds,
the unit will return to the normal Display mode.
1. Slide the SYSTEM SwiTcH to HEAT or cOOl to program the
corresponding system.
2. Press pROGRAM to enter Program mode. (The lCD will begin to
flash)
39
Download from Www.Somanuals.com. All Manuals Search And Download.
M
1
T
W
TH
F
SA SU
AM
PM
2
3
4
HEAT COOL
system
heat
program
off
cool
hold
/return
40
Download from Www.Somanuals.com. All Manuals Search And Download.
METHODS OF OPErATIOn
3. Press Up or DOwN to change the hour. Press pROGRAM to save
the hour and adjust the minute setting.
4. Press Up or DOwN to change the minute. Press pROGRAM to save
the minute setting and adjust the temperature.
5. Press Up or DOwN to change the temperature. Press pROGRAM
again to move to the next program number.
(There are 4 programs per day. If you do not wish to assign 4
programs per day, set up to 4, keeping in mind that the total
program time must equal 24 hours.)
6. repeat steps 2-5 for the remaining days.
7. To review your program settings, press pROGRAM repeatedly to
review the customized programs.
(You can make changes at any time when the thermostat is in
Program mode.)
8. Slide the SYSTEM SElEcTOR SwiTcH to the opposite position and
repeat steps 2-5.
41
Download from Www.Somanuals.com. All Manuals Search And Download.
FILTER
filter
42
Download from Www.Somanuals.com. All Manuals Search And Download.
ICOnS AnD FEATUrES
®
1. InDIGlO night-light - will backlight the display for easy viewing
in the dark. Press any button to illuminate the light.
(If no button is pressed after 5 seconds, the backlight will turn off.)
note: If the thermostat shows a low Battery Warning, the backlight
will not operate. Follow the instructions on pages 42-43 to change
batteries.
2. Filter change indicator - will flash after 400 hours of system use
as a reminder to check or change your filter. Press and hold the
FilTER button for 3 seconds after changing the filter to reset the
filter timer.
(Pressing the Filter button for less than 3 seconds will cause the Filter
change indicator icon to appear. The filter timer will not be affected
unless the button is held for more than 3 seconds.)
note: Clearing the Filter counter will also clear the Energy counter.
See pages 50-51 for more information.
43
Download from Www.Somanuals.com. All Manuals Search And Download.
Hr
Usage Today
Min
44
Download from Www.Somanuals.com. All Manuals Search And Download.
ICOnS AnD FEATUrES, COnT.
3. Energy – calculates energy usage. Press to display the total
operation time for heat and air conditioning for today, yesterday,
last week, or Total. Monitoring energy usage allows you to
optimize energy savings.
Press ENERGY to cycle through Today, Yesterday, This Week, and
Total (up to 999 hours and 59 minutes).
Press and hold ENERGY until the display blinks to reset the
counter.
note: Clearing the Energy monitor counter will also clear the Filter
counter.
4. Daylight savings time - allows for an easy transition during
daylight savings time.
Press DAY/TiME, then Up or DOwN to enter daylight savings time
mode and adjust as needed.
45
Download from Www.Somanuals.com. All Manuals Search And Download.
HEAT COOL
system
heat
off
cool
reset
46
Download from Www.Somanuals.com. All Manuals Search And Download.
ICOnS AnD FEATUrES, COnT.
5. Span setting mode – allows you to adjust the system On/OFF
cycle rate. The default setting is 2 (the system cycles On or OFF
o
o
when the temperature is within 1 F (0.5 C) above and below
the set temperature.) The span setting can be adjusted if your
system is cycling too fast or too slowly.
Press and hold both the Up and DOwN buttons until the word
SPAn appears. Use the Up or DOwN button to adjust the span
setting.
(Up will increase your cycle time by allowing the system to run longer;
Down will decrease your cycle time by causing the system to run for a
shorter length of time.)
Span settings remain the same for HEAT and cOOl system
settings. When batteries are installed, or the unit is RESET, the
span cycle will revert to 2.
47
Download from Www.Somanuals.com. All Manuals Search And Download.
M
PM
4
COOL
STAGE 1
STAGE 2
48
Download from Www.Somanuals.com. All Manuals Search And Download.
ICOnS AnD FEATUrES, COnT.
6. low battery warning – indicates two stages of battery power
shortage.
When the batteries are detected as weak, the icon will flash until
new AA alkaline batteries are installed (Stage 1). If the batteries
become too weak for normal operation, the thermostat enters
the second battery power shortage mode (Stage 2). When
insufficient battery power is left, the battery icon will flash alone
on the display and your system will turn off. The display will be
blank when no battery power is left. The system will remain off
until new batteries are installed.
(Your programs and time settings will be lost if the batteries are
not replaced within one minute.)
The thermostat will resume normal operation after new batteries
are installed.
49
Download from Www.Somanuals.com. All Manuals Search And Download.
hold
/return
50
Download from Www.Somanuals.com. All Manuals Search And Download.
ICOnS AnD FEATUrES, COnT.
7. Auto recovery – allows heating and cooling systems to gradually
recover from an energy-saving setpoint temperature to a comfort
setpoint temperature. Auto recovery calculates the time needed
to adjust the temperature to the next program setting. When
the thermostat is in Auto Recovery mode, the display will flash
alternating messages of rECO and the time. Auto recovery can
be disabled by sliding the recovery switch on the back of the
circuit board to the disable position.
(Auto recovery will not operate if Permanent or Temporary holds are on.)
Press HOlD/RETURN during the Auto recovery process to manually
cancel the recovery.
51
Download from Www.Somanuals.com. All Manuals Search And Download.
52
Download from Www.Somanuals.com. All Manuals Search And Download.
ICOnS AnD FEATUrES, COnT.
8. Error mode – indicates an unexpected battery problem. The
screen will flash an ERR message and shut your system off until
the batteries are replaced with new AA alkaline batteries. You
must reset and reprogram the thermostat after replacing the
batteries if the thermostat has entered Error mode.
9. Auto cut off – automatically turns the system off if the
o
o
o
o
temperature rises above 95 F (35 C) or drops below 40 F (4
C).
(If your HVAC system has malfunctioned, the system will no longer
respond to thermostat controls and the Auto cut off will have no effect.)
53
Download from Www.Somanuals.com. All Manuals Search And Download.
IMPOrTAnT FEATUrES
1. Temperature range
o
o
o
o
99
F
30
F
o
(0 C)
45
F
95
F
o
(35 C)
o
(37 C)
o
(7 C)
Out of Range
Out of Range
Program Range
Display Range
"LO"
"HI"
o
o
<
>
99
30
F
F
2. Compressor Protection
After the system stops running in cooling mode, there
will be a 3.5 minute delay before it can be restarted to
prevent compressor damage due to rapid cycling.
3. resetting the unit
To restore the thermostat to the original factory
settings, press the reset button with a paperclip.
(This will erase any user-programmed settings.)
reset
54
Download from Www.Somanuals.com. All Manuals Search And Download.
TrOUBlESHOOTInG
1. My display will not come on.
1 a. Check batteries and battery connections.
1 b. reset the thermostat.
.............................................................................................
2. The auto fan feature will not operate properly.
2 a. remove the thermostat from the wall plate and set the
HG/HE switch to the correct position.
.............................................................................................
3. My display is erratic.
3 a. reset the thermostat and reprogram your settings.
.............................................................................................
4. The program will not change at my desired setting.
4 a. Check that the time is set properly to AM or PM.
4 b. Make sure the thermostat is not in permanent override
mode.
4 c. Check that the day setting is correct.
55
Download from Www.Somanuals.com. All Manuals Search And Download.
TrOUBlESHOOTInG
5. My heating or cooling will not turn on or off.
5 a. Check the Heat/Cool function switch to ensure it is set to
the desired position.
5 b. Wait. There may be as much as a 4-minute delay before
the system turns on or off to protect the compressor.
5 c. Check the circuit breakers and switches to ensure there is
power to the system.
5 d. replace the batteries.
5 e. If applicable, make sure the furnace blower door is closed
properly.
5 f. If your system has 4 wires, ensure the jumper wire is
installed between the rC and rH terminals.
5 g. Check your system for proper wiring.
.............................................................................................
6. The display will come on, but it will not stay illuminated.
6 a. replace batteries.
56
Download from Www.Somanuals.com. All Manuals Search And Download.
TrOUBlESHOOTInG
7. My system continues to operate when the thermostat is in the off
position.
7 a. replace unit.
7 b. Check your system for proper wiring.
.............................................................................................
8. The lCD screen permanently reads HI, lO, or Err.
8 a. replace unit.
.............................................................................................
9. How do I just operate my thermostat manually?
9 a. Manual operation instructions are on pages 28-31.
57
Download from Www.Somanuals.com. All Manuals Search And Download.
Is there help on the web?
.............................................................................................
Can’t I just call someone?
Sure. The Hunter Technical Support Group is available from 7 am to
7 pm CST M-F and 8 am to 5 pm Saturday. They may be reached
toll-free at 1-888-830-1326.
58
Download from Www.Somanuals.com. All Manuals Search And Download.
|