ENGLISH
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Table of Contents
Congratulations on purchasing your new
What to Expect with
Your Installation
Tools Needed
Mounting Options
Ceiling Bracket
Hunter® ceiling fan! It will provide comfort
and performance in your home or office for
many years. This installation and operation
manual contains complete instructions for
installing and operating your fan.
We are proud of our work and appreciate
the opportunity to supply you with the best
ceiling fan available anywhere in the world.
2
3
9
4
5
Downrod
Wiring
Canopy
Blades
To register your fan, please visit:
Save your receipt for proof of purchase.
6
10
11
Maintenance
& Cleaning
Switch Housing
Light Kit
Troubleshooting
?
?
?
12
13
16
17
1
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
What to Expect with Your Installation
Read and Save These Instructions
This product conforms to UL Standard 507.
If you are unfamiliar
with wiring, use a
qualified electrician.
WARNINGS
w.1 - To reduce the risk of fire, electrical shock, or personal
injury, mount fan directly from building structure and/or
an outlet box marked acceptable for fan support of 70 lbs
(31.8 kg) and use the mounting screws provided with the
outlet box.
,8 Meters
(30 inches)
from blade tip
to nearest wall
or obstruction
2,1 Meters
(7 feet)
from bottom
edge of blade
to the floor
w.2 - To avoid possible electrical shock, before installing
or servicing your fan, disconnect the power by turning
off the circuit breakers to the outlet box and associated
wall switch location. If you cannot lock the circuit breakers
in the off position, securely fasten a prominent warning
device, such as a tag, to the service panel.
Must be able to
secure the fan to
building structure or
fan-rated outlet box
Know your wiring
Assess location
w.3 - To reduce the risk of fire, electrical shock, or motor
damage, use only Hunter Solid State Speed Controls.
w.4 - To reduce the risk of personal injury, do not bend the
blade brackets when installing the blade brackets, balancing
the blades, or cleaning the fan. Do not insert foreign objects in
between rotating fan blades.
You may need a
friend to help you.
Standard Downrod
1
2
3
for ceilings 2,4-3 m (8-10 feet) high
w.5 - This product is not intended to be used by people
(including children) whose physical, sensory, or mental
capacities are different or diminished, or lack of experience
or knowledge, unless such persons receive training or work
under supervision of a person responsible for their safety.
Shorter Downrod
Ceiling angles greater
than 34° will require an
Angled Mounting Kit.
See page 4 for details.
for fans installed close to ceiling
w.6 - Children should be supervised to ensure they do not use
the devices as a toy.
Longer Downrod
for ceilings 3 m (10 feet) or higher
CAUTIONS
c.1 - All wiring must be in accordance with national and local
electrical codes ANSI/NFPA 70. If you are unfamiliar with
wiring, use a qualified electrician.
Check box to see
fan weight
Assess ceiling angle
Select a downrod length
c.2 - Use only Hunter replacement parts.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Tools Needed
Pliers
Wire Strippers
Screwdrivers
Ladder
9/64” Drill Bit
(optional)
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
O
34
CEILING
Mounting Options
If you have a flat ceiling:
Hang your fan by a standard downrod (included).
Standard
Mounting
Support
Structure
Support
Structure
If you have an angled ceiling:
Ceiling
Outlet Box
(required)
1. You will need a longer downrod (sold separately).
Angled
Mounting
2. If your ceiling angle is greater than 34°, you will
also need an Angled Mounting Kit (sold separately).
Ceiling
Outlet Box
(required)
Standard
Mounting
Style
Angled
Mounting
Style
Use the three steps below to determine if your ceiling angle is greater than 34°
1
2
3
34°
FOLD
PLACE
SLIDE
toward ceiling
on dotted line
against wall
Guide Touches
BOTH Ceiling & Wall
Guide Touches
but NOT Ceiling
Wall
Use Standard Mounting
or Low-Profile Mounting
to hang the fan from a flat ceiling.
Use Angled Mounting
to hang the fan from a
vaulted or angled ceiling.
You need BOTH
a Longer
You need ONLY
a Longer
Downrod &
an Angled
Downrod
Mounting Kit
*most common
4
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Ceiling Bracket
OFF
For angled ceilings, point
opening toward peak.
Use wood screws
(included) when securing
to support structure with
Use machine screws
(provided with outlet
box) when securing to
approved electrical outlet existing ceiling fan-rated
box. Drill 9/64” pilot holes
in support structure to aid
outlet box. Make sure
it is securely installed
in securing ceiling bracket and is acceptable for fan
with hardware found in support of 31.8 kg (70 lbs)
the
hardware bag.
or less.
Make sure all four bumpers are
still attached.
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
Refer to warning w.1 on pg. 2
5
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Downrod
Standard Downrod
for ceilings 2,4-3 m
(8-10’) high
skip to next page
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Longer Downrod
for angled
ceilings or
1
2
3
4
5
ceilings 3 m (10’)
or higher
Shorter Downrod
for fans installed
close to ceiling
10
9
8
7
6
Steps 6-10 to reassemble with new pipe
6
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Downrod (continued)
1 cm
(3/8”)
20 cm
(8”)
Remove the pre-installed
setscrew so that the downrod
can be inserted.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
The wires can be cut, but
leave at least 8” extending
from the top of the downrod.
Tighten the setscrew
with pliers. DO NOT
HAND TIGHTEN.
20 cm
(8”)
1 cm
(3/8”)
If the setscrew is not tightened
securely, the fan may fall.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Downrod (continued)
Put the wires and downrod through the canopy.
Let the canopy sit loosely on top of the fan.
DO NOT PICK THE FAN UP BY THE CANOPY
OR WIRES. Place the downrod ball into the slot
in the ceiling bracket.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Wiring
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then twist
clockwise until tight.
M
I
N
O
G
R
F
For Dual Switches
Using the orange wire
connectors from the
Green/Yellow
Stripe
hardware bag, connect
the white wire (grounded)
from the ceiling to the
white wire from the fan.
Connect the black wire
(ungrounded) from the
ceiling to the black wire
from the fan. Connect the
second (ungrounded) wire
from the ceiling to the blue
wire from the fan.
For a Single Switch
Using the orange wire
connectors from the
Using an orange wire
connector from the
hardware bag, connect
the 3 grounding wires
(green, green/yellow
stripe, or bare copper)
coming from the ceiling,
downrod, and hanging
bracket.
hardware bag, connect the
black wire (ungrounded)
from the ceiling to the black
and the blue wires from the
fan. Connect the white wire
(grounded) from the ceiling to
the white wire from the fan.
F
N
O
A
M
M
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
9
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Canopy
Screw
Holes
Position the canopy so that, when
lifted into place, the canopy fits into
Lift the canopy into place so that
the screw holes are aligned.
Insert the two canopy screws
found in the hardware bag.
the hanging bracket as shown.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Blades
Put the blade washers, found in the
hardware bag, onto the blade screws, found
in the hardware bag. Then install the blade
screws to secure each blade to a blade iron.
Lightly attach the blade irons to the motor
with screws found in the hardware bag, then
securely tighten after both screws are attached.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Switch Housing
Screw two switch housing assembly screws,
Feed the wire plug through the center
hole of the upper switch housing, then lift
the keyhole slots around the screws and
twist counterclockwise.
Insert the third screw, found in the
hardware bag, into place and then tighten
all three screws.
found in the hardware bag, halfway
into the motor housing. It does not matter
which two screw holes you choose.
Make sure the upper switch housing is securely
attached to the mounting plate. Failure to properly
secure all 3 assembly screws could result in the switch
housing fixture falling.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Light Kit
Light Kit
Assembly
Screw
Partially install two of the light kit assembly
screws, found in the hardware bag, into the
upper switch housing. Lift the light kit assembly
and connect the plugs from the upper and
lower switch housings. Make sure to line up the
colored markings on the connectors.
Align the keyhole slots in the light kit assembly
with the two switch housing screws. Lift the
light kit assembly and twist counterclockwise
to lock into place. Thread the pull chains
through the holes in the light kit.
Install the third light kit assembly screw.
Tighten all three screws securely.
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
switch housing screws could result in the light fixture falling.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Light Kit (continued)
Metal
Plate
Inner
Glass
Screw
Holes
Globe
Keeper
Finial
Cap
Finial
Install a CFL bulb into each of the sockets.
When necessary, replace with bulbs of the
same type and wattage.
Lift the inner glass flush against the metal
plate and install the globe keeper. Thread the
pull chains through the holes in the finial cap.
Screw the finial onto the threaded rod.
Raise the outer glass to the light kit and
align the screw holes in the outer glass
with the screw holes in the posts of the
upper switch housing.
Make sure the lower switch housing is securely attached to
the upper switch housing. Failure to properly secure all three
switch housing screws could result in the light fixture falling.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Light Kit (continued)
Thumbscrew
To attach the outer glass, install the
thumbscrews and tighten securely.
Connect the appropriate pull chain pendant
to each of the short chains. The fan pull chain
controls the speed: from high to off. The light
pull chain controls the light fixture: on and off.
See next page for fan
operation instructions.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Maintenance & Cleaning
Inner
Glass
ON
Globe
Keeper
Reverse
switch
Finial
Cap
Finial
Changing the bulbs - unscrew
the finial and remove it from the
threaded rod. Remove the finial cap
and unscrew the globe keeper while
supporting the inner glass with your
other hand. Carefully remove the inner
glass. Unscrew the bulbs and replace
with bulbs of same type and wattage.
Reinstall the inner glass assembly.
Changing the direction of air
flow - unscrew the finial and
remove it from the threaded
rod. Remove the finial cap and
unscrew the globe keeper while
supporting the inner glass with
your other hand. Carefully remove
the inner glass. Move the reverse
switch to the opposite position.
Reinstall the inner glass assembly.
Cleaning the fan - use soft
brushes or cloths to prevent
scratching. Cleaning products
may damage the finishes.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
Troubleshooting
Fan doesn’t work
Noisy Operation
Excessive wobbling
• Make sure power switch is on.
• Tighten the blade and blade
iron screws until they are snug.
• Tighten all of the blade and
blade iron screws until they
are snug.
• Pull the pull chain to make sure
it is on.
• Check to see if any of the
blades are cracked. If so, replace
all of the blades.
• Turn the power off, support
the fan carefully, and check
that the hanger ball is
properly seated.
• Push the motor reversing switch
firmly left or right to ensure that
it is engaged.
• Check the circuit breaker to
ensure the power is turned on.
• Use the provided balancing
kit and instructions to balance
the fan.
• Make sure the blades spin freely.
• Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on page 9.
• Check the plug connection in
the switch housing.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
MB519-01 • 03/13/15 • © Hunter Fan Company
|