1.888.830.1326
Table of Contents
What to Expect with
Your Installation
Congratulations on purchasing
your new Hunter® ceiling fan! It will
provide comfort and performance
in your home or office for many
years. This installation and operation
manual contains complete
Tools Needed
Mounting Options
Ceiling Bracket
instructions for installing and
operating your fan.
2
3
7
4
5
We are proud of our work and
appreciate the opportunity to
supply you with the best ceiling fan
available anywhere in the world.
Assembling the Top
Housing
Downrod
Wiring
Canopy
To register your fan, please visit:
Save your receipt for proof of purchase.
6
10
11
Operation,
Maintenance & Cleaning
Blades
Light Kit
Remote Control
Troubleshooting
?
?
?
12
13
16
17
19
1
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Tools Needed
Pliers
Wire Strippers
Screwdrivers
Ladder
9/64” Drill Bit
(optional)
Power Drill
(optional)
If mounting to a support structure, you will also need these tools.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
O
34
CEILING
1.866.268.1936
Mounting Options
If you have a flat ceiling:
Hang your fan by a standard downrod (included).
Standard
Mounting
Support
Structure
Support
Structure
If you have an angled ceiling:
Ceiling
Outlet Box
(required)
1. You will need a longer downrod (sold separately).
Angled
Mounting
2. If your ceiling angle is greater than 34°, you will
also need an Angled Mounting Kit (sold separately).
Ceiling
Outlet Box
(required)
Standard
Mounting
Style
Angled
Mounting
Style
Use the three steps below to determine if your ceiling angle is greater than 34°
1
2
3
34°
PLACE
SLIDE
toward ceiling
FOLD
against wall
on dotted line
Guide Touches
BOTH Ceiling & Wall
Guide Touches
but NOT Ceiling
Wall
Use Standard Mounting
or Low-Profile Mounting
Use Angled Mounting
to hang the fan from a
to hang the fan from a flat ceiling.
vaulted or angled ceiling.
You need BOTH
a Longer
You need ONLY
a Longer
Downrod &
an Angled
Downrod
Mounting Kit
*most common
4
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Ceiling Bracket
OFF
For angled ceilings, point
opening toward peak.
Use wood screws
(included) when securing
to support structure with
Use machine screws
(provided with outlet
box) when securing to
approved electrical outlet existing ceiling fan-rated
box. Drill 9/64” pilot holes
in support structure to aid
outlet box. Make sure
it is securely installed
in securing ceiling bracket and is acceptable for fan
with hardware found in support of 31.8 kg (70 lbs)
the
hardware bag.
or less.
Make sure all four bumpers are
If you are unable to do this,
call Technical Support at
1-888-830-1326.
still attached.
To avoid possible electrical shock, before
installing your fan, disconnect the power by
turning off the circuit breakers to the outlet
box associated with the wall switch location.
Refer to warning w.1 on pg. 2
5
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Assembling the Top Housing
Upper Motor
Cover Screw
Remove the pre-installed
setscrew so that the downrod
can be inserted.
To assemble the housing to the
hanger adapter, align the three
raised tabs on the hanger adapter
with the three narrow notches in
the top housing. Make certain the
Install three upper motor cover
screws, found in the
hardware
bag, and tighten them securely.
housing sits flat on the adapter.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Downrod
Standard
skip to next page
Downrod
for ceilings 8-10’ high
If you need a different downrod length follow these steps:
Steps 1-5 to remove standard downrod pipe
Longer
Downrod
for angled
ceilings or
ceilings 10’ or
higher
1
2
3
4
5
Shorter
Downrod
for fans installed
close to ceiling
10
9
8
7
6
Steps 6-10 to reassemble with new pipe
7
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Downrod (continued)
The wires can be cut, but leave at least 8”
extending from the top of the downrod.
Hand tighten the downrod (at
least 4-5 full turns) until it stops.
Tighten the setscrew with pliers.
DO NOT HAND TIGHTEN.
8”
3/8”
If the setscrew is not tightened
securely, the fan may fall.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Downrod (continued)
Put the wires and downrod through the
canopy. Let the canopy sit loosely on top
of the fan.
DO NOT PICK THE FAN UP BY THE
CANOPY OR WIRES. Place the downrod
ball into the slot in the ceiling bracket.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Wiring
Note: To connect the wires,
hold the bare metal leads
together and place a wire
connector over them, then twist
clockwise until tight.
Using the blue wire
connectors from the remote
control hardware bag,
connect the white wire
from the receiver (marked
“common out”) to the white
wire from fan. Connect the
black wire from the receiver
(marked “fan out”) to the
black wire from the fan.
Connect the blue wire from
the receiver (marked ”light
out”) to the blue wire from
the fan. The red wire from
the receiver will not be used,
it has a pre-installed wire
terminator.
Using an orange wire
connector from
green/yellow stripe
the
hardware bag,
connect the black wire
(ungrounded) from the
ceiling to the black wire
from the receiver (marked
“live in”). Connect the
white wire (grounded)
from the ceiling to
Using an orange wire
connector from
the hardware bag,
connect the 3 grounding
wires (green, green/
yellow stripe, or bare
copper) coming from the
ceiling, downrod, and
hanging bracket.
the white wire from
the receiver (marked
“neutral in” or
“common in”).
M
Turn the splices upward and push them carefully back through the hanger bracket
into the outlet box. Spread the wires apart, with the grounded wires on one side of
the outlet box and the ungrounded wires on the other side of the outlet box.
Refer to CAUTION c.1 on pg. 2
10
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Canopy
Screw
Holes
Position the canopy so that, when
lifted into place, the canopy fits into
Lift the canopy into place so that
the screw holes are aligned.
Insert the two canopy screws
found in the
hardware bag.
the hanging bracket as shown.
Note: Fan style may vary.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Blades
Holes
Insert the blade into the slot. Align the holes on
the blade with the holes in the fan motor.
Attach the blade to the motor using the flat
washers from the hardware bag and blade
assembly screws found in the hardware bag.
Repeat for each blade.
Your blades are shielded with Dust Armor® which
is a nanotechnology coating that repels dust. For
cleaning the fan, use soft brushes or cloths to prevent
scratching. Cleaning agents may damage the finishes.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Light Kit
Attachment Screw
Partially install two attachment
Thread the 9-pin plug connector from the
fan through the light kit.
Align the keyholes in the light kit with the two
partially installed screws and turn the light kit
clockwise until the screws are in the narrow
ends of the keyholes.
screws, found in the
hardware
bag, into the light kit mounting plate.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Light Kit (continued)
Attachment Screw
Install the remaining attachment
screw to secure the light kit to
the mounting plate. Securely
tighten all three screws.
Connect the upper 9-pin plug
connector from the fan to the
lower 9-pin plug connector in the
light kit.
Align the two screw screw holes
and install the switch housing
assembly screws, found in the
hardware bag.
Install bulb.
Make sure the light kit is securely attached to the mounting
plate. Failure to properly secure all three assembly screws
could result in the light fixture falling.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Light Kit (continued)
Globe
Assembly
Screw
4 Pin Plug
Trim Ring
Glass Globe
Connect the 4 pin plug from the ballast to
Place the glass globe into the globe trim
ring. Align the three holes in the trim
ring with the three holes in the light
kit. Install and securely tighten all three
globe assembly screws, found in the
hardware bag.
the fluorescent bulb.
See next page for fan
operation instructions.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Remote Control
Battery
Door
Fan Off
High
ON
Phillips
Head
Screw
To access the battery compartment, remove
the small Phillips head screw that secures the
battery door to the transmitter assembly. The
battery should be installed with the positive
(+) side up. Replace with a CR2032 battery
when necessary.
Note: The remote must be paired before
the fan will operate.
Within 3 minutes of restoring power to
the fan, press both the Fan Off button and
the High button for at least 4 seconds. Your
fan will turn on low to indicate successful
syncing. If it does not, turn off power to your
fan, wait 1 minute then try again. If using the
transmitter with multiple fans, repeat this
process for each fan.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Operation, Maintenance, & Cleaning
Medium
Speed
Fan
Off
High
Speed
Switch Cover Plate
Light
Low
Speed
Reverse
Switch
Rocker- Style
Plate
Removed
Tabs
To turn on fan, press a fan speed button. Speeds
range from off (0) to high (3). Quickly press the
Light button to turn the lights off and on.
Hold the Light button to raise and dim the
light level.
To install the transmitter cradle, remove the
two screws holding the switch cover plate. Do
not remove the cover plate. Orient the cradle
by lining up the two mounting holes with
those on the cover plate. Insert and tighten
the screws. Do not over tighten.
To switch the direction of air flow, remove
the globe on the fan by removing the globe
assembly screws, the glass, and trim ring. Flip
the black switch to change the direction.
Note: For rocker-style cover plates, break off
the tabs by pushing outward.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Operation, Maintenance, & Cleaning (continued)
Safe-Exit
The Safe-Exit Program gives you about thirty seconds
of light when you turn the lights off to exit the room
before the lights go out.To use Safe-Exit:
• Press the Fan Off button for at least three seconds to
initiate the Safe-Exit Mode.
• The lights will flash for visual confirmation.
• The lights will stay on 50% brightness for 15 seconds and
then begin to dim. After a total of 30 seconds, the lights
will be completely off.
Note: For CFL lighting, the lights will stay on 100%
brightness for 30 seconds. After a total of 30 seconds, the
lights will be completely off.
When cleaning the fan, use soft brushes or cloths
to prevent scratching. Cleaning products may
damage the finishes.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
M3535-01 • 06/18/13 • © Hunter Fan Company
1.888.830.1326
Troubleshooting
Fan doesn’t work
Excessive wobbling
• Make sure power switch is on.
• Tighten all of the blade and
blade iron screws until they
are snug.
• Push the motor reversing switch
firmly left or right to ensure that
it is engaged.
Hunter fans have the power to cut your cooling costs up
to 40%.
Beat the High Cost of Cooling
• Use the provided balancing
kit and instructions to balance
the fan.
The air movement created by a Hunter ceiling fan
lets you set your thermostat higher and still stay
comfortable. Every degree you raise the thermostat
saves up to 7% on energy costs. So, you can cut back on
expensive air conditioning ... and save up to 40%* on
cooling. In winter, your Hunter fan recirculates warm air
and saves up to 10%* on heating bills.
* On average at low speed settings. Your savings may
vary based on climate, building type and thermostat
setting.
• Check the circuit breaker to
ensure the power is turned on.
• Make sure the blades spin freely.
• Turn off power from the circuit
breaker, then loosen the canopy
and check all the connections
according to the wiring diagram
on page 10.
Noisy Operation
• Tighten the blade and blade
iron screws until they are snug.
Save Energy and Money While Protecting
the Environment
Congratulations! You’re saving energy and money while
protecting the environment by purchasing this ENERGY
• Check to see if any of the
blades are cracked. If so, replace
all of the blades.
• Check the plug connection in
the switch housing.
STAR qualified Hunter ceiling fan! With this purchase, you
are doing your part to protect the environment. In 2010,
ENERGY STAR qualified ceiling fans are projected to cut
air pollution by more than 500 million pounds!
Your new ceiling fan has earned the ENERGY STAR label
because it meets high energy efficiency specifications
set by the Environmental Protection Agency (EPA).
ENERGY STAR labeled ceiling fans save energy because
they have more efficient fan motors and air delivery due
to more aerodynamic blade configurations. Ceiling fan
models bearing the ENERGY STAR label move air 14 -
20% more efficiently than typical ceiling fan models.
For more information on ENERGY STAR visit
Remote control of fan is erratic
Transmitter only works when
held at close range
• Make sure the battery is
installed correctly.
•
Install a fresh battery.
• Install a fresh battery.
19
Download from Www.Somanuals.com. All Manuals Search And Download.