For Your Records and
Warranty Assistance
Camille
For reference, also attach your receipt or a copy
of your receipt to the manual.
Owner’s Guide and Installation Manual
__________________________________________
Model Name
__________________________________________
Model No.
__________________________________________
Date Purchased
__________________________________________
Where Purchased
Form M0021-01
20140521
©2014 Hunter Fan Co.
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing the Fan Site
Step 1 - Choose the Fan Site
Proper ceiling fan location and attachment to the building
structure are essential for safety, reliable operation, maximum
efficiency, and energy savings.
30” From
Wall or
Choose a fan site where:
8’ Minimum
Ceiling
Nearest
• No object can come in contact with the rotating fan blades during
normal operation.
Obstruction
7’ Minimum
Blades to
Floor
Height
• e fan blades are at least 7 feet above the floor and the ceiling is
at least 8 feet high.
• e fan blades have no obstructions to airflow, such as walls or
posts, within 30 inches of the fan blade tips.
• e fan is directly below a joist or support brace that will hold the
outlet box and the full weight of the fan.
Checklist for Existing Fan Site
If you want to use an existing fan site, complete the following checklist to determine
if the site is acceptable and safe for your new Hunter fan. If you cannot check off
every item, prepare a new fan site as described on this page.
Suitable Existing Fan Site
Fan Support
System
Fan Support System
• Fan attaches directly to building structure.
• Fan support system will hold full weight of the fan and light kit.
Ceiling Hole
• e outlet box clearance hole is directly below the joist or support brace.
Outlet Box
• e outlet box is an UL-approved octagonal 4” x 1-1/2” outlet box (or as specified
by the support brace manufacturer).
• e outlet box is secured to the joist or support brace by wood screws and washers
through the inner holes of outlet box.
• e outer holes of the outlet box are aligned with joist or support brace.
• e bottom of the outlet box is recessed a minimum of 1/16” into ceiling.
Wiring
• e electrical cable is secured to outlet box by an approved connector.
• Six inches of lead wires extend from outlet box.
Outlet Box
Wiring
Fan Support
System
If your existing fan site is suitable, skip ahead to Section 2 • Installing the Ceiling Plate.
3
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
Preparing the Fan Site (continued)
Step 2 - Cut the Ceiling Hole
2-1. Locate the site for the ceiling hole directly below the joist or support brace that
will hold the outlet box and fan.
2-2. Cut a 4” diameter hole through the drywall or plaster of the ceiling. You will use
the hole to install the support brace and outlet box.
Step 3 - Install a Support Brace, If Necessary
Determine if there is a ceiling joist directly above the ceiling hole. If the joist is there,
determine if it is positioned to allow you to recess the outlet box a minimum of
1/16” into the ceiling. If NOT, install a support brace as follows:
3-1. Attach a 2” x 4” support brace between two joists. Position it to allow you to
recess the bottom of the outlet box a minimum of 1/16” into the ceiling.
Steps 2 – 3
3-2. Check the support brace to ensure it will support the full weight of the fan and
light kit.
Step 4 - Install the Outlet Box
4-1. Obtain a UL-approved octagonal 4” x 1-1/2” outlet box, plus two #8 x 1-1/2”
wood screws and washers, available from any hardware store or electrical supply
house.
4-2. Orient the outlet box so that both the inner and outer holes in the box align
with the joist or support brace.
4-3. Drill pilot holes no larger than the minor diameter of the wood screws (5/64”)
through the inner holes of the outlet box.
Step 4
4-4. Attach the outlet box directly to the support brace or joist with two #8 x 1-1/2”
wood screws and washers. e bottom of the outlet box must be recessed a
minimum of 1/16” into the ceiling.
Step 5 - Prepare the Wiring
5-1. Make sure the circuit breakers to the fan supply line leads and associated wall
switch location are turned off . If you cannot lock the circuit breakers in the
off position, securely fasten a prominent warning device, such as a tag, to the
service panel.
5-2. read the fan supply line through the outlet box so that the fan supply line
extends at least 6” beyond the box.
5-3. Attach the fan supply line to the outlet box with an approved connector,
available at any hardware store or electrical supply house.
5-4. Make certain the wiring meets all national and local standards and ANSI/NFPA 70.
Step 5
CAUTION: All wiring must be in
accordance with national and local
electrical codes and ANSI/NFPA 70. If
you are unfamiliar with wiring, use a
qualified electrician.
You have now successfully prepared your ceiling fan site. For instructions to install
your ceiling fan, go to your fan manual and continue with Section 2 • Installing the
Ceiling Plate.
4
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
Installer’s Choice and Optional Accessories
Understanding Mounting and Installer’s Choice®
Support Brace
Hunter’s patented 2-position mounting system provides you maximum
installation flexibility and ease. You can install your Hunter fan in one
of two ways, depending on ceiling height and your preference: Standard
or Angled mounting. e steps in this manual include instructions for
both Installer’s Choice mounting methods.
Ceiling
Outlet Box
Standard
Mounting
Style
Considering Optional Accessories
Consider using Hunter’s optional accessories, including a wall-mounted
or remote speed control. To install and use the accessories, follow
the instructions included with each product. For quiet and optimum
performance of your Hunter fan, use only Hunter speed controls.
Standard Mounting hangs from the
ceiling by a downrod (included).
For ceilings higher than 8 feet, you can purchase
Hunter extension downrods. All Hunter fans use
sturdy 3/4” diameter pipe to assure stability and
wobble-free performance.
Support Brace
Ceiling
Outlet Box
CAUTION: To reduce the risk of personal
injury, attach the fan directly to the support
structure of the building according to these
instructions, and use only the hardware
supplied.
8
12
Angled
Mounting
Style
Angled Mounting recommended for a
vaulted or angled ceiling
5
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
1 • Getting Ready
To install a ceiling fan, be sure you can do the following:
• Locate the ceiling joist or other suitable support in ceiling.
• Drill holes for and install wood screws.
• Identify and connect electrical wires.
• Lift 40 pounds.
If you need help installing the fan, your Hunter fan dealer can direct
you to a licensed installer or electrician.
Gathering the Tools
You will need the following tools for installing the fan:
• Electric drill with 9/64” bit
• Keyhole saw
• 2’ x 4’ support brace
• UL-approved octagonal 4” x 1-1/2” outlet box
• Two #8 x 1-1/2” wood screws and washers
• Approved connector for electrical wire
• Standard screwdriver (magnetic tip recommended)
• Phillips-head screwdriver (magnetic tip recommended)
• Wrench or pliers
Installing Multiple Fans?
If you are installing more than
one fan, keep the fan blades and
blade irons (if applicable) in sets,
as they were shipped.
• Ladder (height dependent upon installation site)
Checking Your Fan Parts
Carefully unpack your fan to avoid damage to the fan parts. Refer to
the included Parts Guide. Check for any shipping damage to the motor
or fan blades. If any parts are missing or damaged, contact your Hunter
dealer or call Hunter Technical Support Department at 888-830-1326
(In Canada, call 866-268-1936).
6
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
2 • Installing the Ceiling Bracket
CAUTION: To avoid possible electrical shock, before installing your fan,
Isolator
Ceiling
disconnect the power by turning off the circuit breakers to the outlet box
and associated wall switch location. If you cannot lock the circuit breakers
in the off position, securely fasten a prominent warning device, such as a
tag, to the service panel.
Bracket
2-1. Note: e ceiling bracket may be mounted to an existing ceiling-
Step 2-2
-fan-rated outlet box. If the outlet box is not ceiling-fan-rated,
Drill two pilot holes into the wood support structure.
e pilot holes should be 9/64” in diameter and through the
outermost holes in the outlet box.
2-2. Your fan comes with four neoprene noise isolators. Position the
isolators between the ceiling bracket and the ceiling by inserting
the raised areas on each isolator into the holes in the ceiling
bracket.
2-3. Align the slotted holes in the ceiling bracket with the pilot holes
you drilled in the wood support structure.
2-4. Place a flat washer on each of the two 3” wood screws and pass
the screws through the slotted holes in the ceiling bracket into the
pilot holes you drilled.
2-5. Tighten the screws into the 9/64” pilot holes; do not use lubricants
on the screws. Do not over tighten. Note: e isolators should be
flush against the ceiling.
Steps 2-3 – 2-5
Flat Washer
3” Wood
Screw
For angled ceilings, point
opening toward peak
7
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
3 • Assembling and Hanging the Fan
WARNING: Fan may fall if not assembled as directed in these
installation instructions.
Downrod
You can assemble your fan for standard or angled mounting as
shown in steps below.
3-1. Unbundle the wires from the fan.
3-2. Feed the wires from the fan through the downrod.
Note: Make sure all the wires are on the same side of the metal
dowel pin inside the downrod.
3-3. Loosen the square head setscrew on the adapter in order to
install the downrod.
Canopy
Adapter
Setscrew
3-4. Insert the downrod into the adapter. Tighten by turning the
downrod assembly at least 4-5 full turns until it stops.
Steps 3-1 – 3-4
Note: When the downrod assembly is fully installed, 2-3 threads
on the pipe will still be visible; this is normal. Securely
retighten the setscrew with a wrench or pliers.
Ceiling
Bracket
Downrod
WARNING: If the setscrew is not tightened securely, the fan
may fall.
3-5. (Optional) - e wires can be cut (shortened), but leave at
least 8” extending from the top of the downrod.
3-6. Raise the fan and place the downrod ball into the ceiling bracket.
Step 3-6
8
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
4 • Wiring the Fan
All wiring must be in accordance with national and local electrical
codes and ANSI/NFPA 70. If you are unfamiliar with wiring, use a
qualified electrician.
E
4-1. Make sure the power is still off at the breaker box.
4-2. To connect the wires, hold the bare metal leads together and place a
wire connector over them, then twist clockwise until tight. For all wire
connections use the wire connector provided.
green with
yellow stripe
CAUTION: Be sure no bare wire or wire strands are visible after
making connections.
4-3. Using an orange wire connector, connect the green or bare wire
(grounding) wire from the ceiling to the green with yellow striped
wire from the ceiling bracket and the green with yellow striped wire
from the downrod.
4-4. Using the orange wire connectors, connect the blue wire from the
receiver to the blue wire (or possibly black with white stripe wire)
from the fan. Connect the yellow wire from the receiver to the black
wire from the fan.
Step 4-3
Wire
Connector
M
Step 4-4
9
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
4 • Wiring the Fan (continued)
4-5. Using the orange wire connectors, connect the black wire
(ungrounded) from the ceiling to the black wire from the receiver.
Connect the white wire (grounded) from the ceiling to both the white
wire from the receiver and the white wire from the fan.
4-6. Check each connection to make sure no bare wire or wire strands are
visible. Turn wire connectors upward and push them up into the outlet
box. Be sure to separate the grounded wires from the ungrounded
wires inside the outlet box.
4-7. Position the receiver in the canopy so that the antenna is close to the
edge of the ceiling bracket for clear reception.
white
Step 4-5
5 • Installing the Canopy
5-1. Raise the canopy over the ceiling bracket and
align the two holes of the canopy and the
ceiling bracket.
5-2. Insert and tighten the canopy screws securely.
Canopy
Screw
Hanger
Bracket
Canopy Screw
Canopy
Steps 5-2
Step 5-1
10
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
6 • Assembling the Blades
Step 6-1 (Detail)
6-1. Insert grommets into the holes in the blades.
6-2. Install one blade onto a blade iron with three blade assembly
screws.
6-3. Repeat Steps 6-1 – 6-2 until all three blades are installed.
Grommet
Steps 6-1 – 6-2
Blade Assembly
Screw
11
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
7 • Completing Your Installation With a Bowl Light Fixture
WARNING: Use only the light fixture supplied with this fan model.
7-1. Partially install two housing assembly screws into the mounting
plate on the bottom of the fan.
7-2. Feed the upper plug connector from the motor through the
center opening of the shroud.
7-3. Slide the partially installed screws through the keyhole slots in the
shroud. Turn the shroud counter-clockwise until the screws are
nestled in the narrow ends of the keyhole slots.
7-4. Install a third housing assembly screw into the remaining screw
hole in the shroud. Securely tighten all three screws.
7-5. Install six #6-32 machine screws into the outer holes in the shroud.
Step 7-4
Housing
Assembly
Screw
Shroud
Step 7-5
12
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
7 • Completing Your Installation With a Bowl Light Fixture (Continued)
7-6. Connect the upper plug connector from the fan to the lower plug
connector in the light fixture.
Note: Both plug connectors are polarized and will only fit together
one way. Make sure the connectors are properly aligned before
connecting them. Incorrect connection could cause improper
operation and damage to the product.
7-7. Partially install two housing assembly screws into the shroud.
7-8. Slide the keyhole slots in the light fixture into the partially
installed screws. Turn the light kit counter-clockwise until the
screws are nestled in the narrow ends of the keyhole slots.
7-9. Install a third housing assembly screw into the remaining screw
hole in the light fixture. Securely tighten all three screws.
Step 7-7
Housing
CAUTION: Make sure the shroud is securely attached to the
switch housing mounting plate. Failure to properly attach and
tighten all three assembly screws could result in the switch housing
Assembly
Screw
and light fixture falling.
Note: In compliance with US federal energy regulations, this
ceiling fan contains a device that restricts its light output.
Exceeding the wattage limit marked on the MAX wattage
sticker affixed to the light socket(s) may result in fire hazard
or improper operation.
13
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
7 • Completing Your Installation With a Bowl Light Fixture (Continued)
7-10. Install the included bulbs (40 W max).
7-11. Hold the glass bowl up so it fits in the shroud.
7-12. Hold the cover plate up to the bottom of the glass
bowl and secure them both by screwing the finial into
the threaded rod on the bottom of the light fixture.
7-13. Attach the extra pull chains with pendants (included)
to the light and fan pull chains using the breakaway
connector. (You may find the breakaway connector
on the end of the extra chains.)
Step 7-10
Breakaway
Connector
Steps 7-10 – 7-11
14
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
8 • Operating the Remote Control and Mounting the Holder
The Safe-Exit Program gives you about 30
8-1. Turn on electrical power to the fan.
seconds of light when you turn the lights off
to exit the room before the lights go out.To
use Safe-Exit:
8-2. To install or replace the battery, remove the door from
the back of the transmitter. Insert the battery into the
compartment, observing proper polarity placement.
•
Press the Fan Off button for at least three seconds to
initiate the Safe-Exit Mode.
Note: e remote must be paired before the fan will
operate.
•
•
The lights will flash for visual confirmation.
The lights will stay on 50% brightness for 15 seconds and
then begin to dim. After a total of 30 seconds, the lights will
be completely off.
8-3. Within 3 minutes of restoring power to the fan, press
both the Fan Off button and the High button for at
least 4 seconds. Your fan will turn on low to indicate
successful syncing. If it does not, turn off power to your
fan, wait 1 minute then try again. If using the transmitter
with multiple fans, repeat this process for each fan.
Note: For CFL lighting, the lights will stay on 100%
brightness for 30 seconds. After a total of 30 seconds, the
lights will be completely off.
Fan Speed
Medium
8-4 e remote has individual buttons for setting the fan
speed and light. Refer to the figure on the right.
Fan Off
Note: For best operation, start the fan by pressing high,
then select your desired speed.
Fan Speed
Low
Fan Speed
High
8-5. e light button turns the light. Push the light button
again to turn off the light.
Fan Light
8-6. When necessary, replace the battery with a 12 V alkaline
battery.
8-7. You can mount the remote holder to any toggle switch
plate with the screws already in the switch plate. Or, you
can simply mount the remote holder on the wall.
Attention: Use the pull chain switch to set the fan speed
to the position BEFORE installation. Do not use pull
chain switch to change the fan speed after installation,
as damage to your fan or remote may result. e speed
of the fan should only be changed by the Hunter control.
Set the ceiling fan light kit to the ON position before
installation. e light level should only be changed by the
Hunter control.
Step 8-7
15
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
9 • Operating and Cleaning Your Ceiling Fan
9-1. e remote controls power to the fan. e fan has four settings
in sequence: High, Medium, Low and Off.
9-2. Ceiling fans work best by blowing air downward
(counterclockwise blade rotation) in warm weather to cool the
room with a direct breeze. In winter, having the fan draw air
upward (clockwise blade rotation) will distribute the warmer air
trapped at the ceiling around the room without causing a draft.
9-3. For cleaning finishes, use a soft brush or lint-free cloth to
prevent scratching. A vacuum cleaner brush nozzle can remove
heavier dust. Remove surface smudges or accumulated dirt and
dust using a mild detergent and a slightly dampened cloth. You
may use an artistic agent, but never abrasive cleaning agents as
they will damage the finish.
In warm weather, use
downward air flow pattern
9-4. Clean wood finish blades with a furniture polishing cloth.
Occasionally, apply a light coat of furniture polish for added
protection and beauty. Clean painted and high-gloss blades in
the same manner as the fan finish.
In cold weather, use upward
air flow pattern
To Change Airflow Direction
Turn the fan off and let it come to a complete stop.
Unscrew the cap at the bottom of the glass globe
and remove the cap, finial, and glass shade. Slide the
reversing switch on the fan to the opposite position.
After reinstalling glass, finial, and cap, restart fan.
Reversing
Switch
16
M0021-01 • 05/21/14 • Hunter Fan Company
Download from Www.Somanuals.com. All Manuals Search And Download.
10 • Troubleshooting
Problem: Nothing happens; fan does not move
1. Turn power on, replace fuse, or reset breaker.
2. Loosen canopy, check all connections according to the wiring the fan section.
3. Check the plug connection in the switch housing.
4. Push motor reversing switch firmly left or right to ensure that the switch is engaged.
5. Pull the pull chain to ensure it is on.
6. Remove the shipping bumpers.
Problem: Noisy operation
1. Tighten the blade assembly screws and blade iron armature screws until snug.
2. Check to see if the blade is cracked. If so, replace all the blades.
Problem: Excessive wobbling
1. Make sure the blades are securely attached to the blade irons according to the blade assembly instructions
provided.
2. After thoroughly verifying the blades are securely attached to the blade irons, follow the instructions in the
enclosed balancing kit to balance the fan.
3. Turn power off, support fan very carefully, and check that the hanger ball is properly seated.
Problem: Lights shut off suddenly, but fan is still operating
1. Check to make sure the wattage and type of the light bulbs that are installed meet the specifications on the
light socket.
2. Turn the power to the fan off at the wall switch. Wait 5 minutes, then resume power to the fan.
Problem: CFL bulbs flicker when controlled by a dimming remote or wall control
1. CFL light bulbs are not usually made for dimming. Replace the CFL bulbs with dimmable light bulbs, or install
the fan in a location without a dimming control.
If you need parts or service assistance, please call
888-830-1326 (In Canada, call 866-268-1936) or
visit us at our website at
Hunter Fan Company
7130 Goodlett Farms Parkway #400
Memphis, Tennessee 38016
17
M0021-01 • 05/21/14 • Hunter Fan Company