InTroduCTIon  
Thank you for purchasing the Total Air Purification System  
from Hunter Fan Company. You have purchased our  
latest development in Portable Air Purification Systems.  
This system has been developed to improve the quality of  
the air you breathe.  
Our Permanent HEPA Air Purification System out  
performs other air purification systems by quickly and  
effectively removing dust, smoke, and pollen particles as  
small as 0.3 microns in size. The following innovative  
features are included in your Hunter Air Purifier.  
3 High Particulate Efficiency: The permanent  
HEPA filter will remove 99.9% of particles as small as  
0.3 micron particles from the air that passes through  
the filter.  
3 Washable Pre-Filter: The washable pre-filter is  
permanent and can be cleaned and reused.  
3 UVC Lamp: This Hunter Air Purifier is equipped  
with a UVC germicidal lamp. UVC technology is a  
proven germicide that is accepted by the FDA and  
EPA as having the ability to kill pathogens in air that  
are exposed to UVC light.  
3 Photocatalitic Oxidation: Reduces the amount  
of toxic VOCs in the air caused by household cleaners  
and products.  
3 Oxygenating Catalyst: Converts ozone and  
smog into oxygen for cleaner air and peace of mind.  
safeTy InsTruCTIons  
IMPORTANT!  
READ ALL INSTRUCTIONS BEFORE USING THIS AIR  
PURIFIER.  
1. WARNING: This Air Purifier emits UVC radiation that  
may cause eye and/or skin irritation. RG-3. Avoid  
exposing eyes and skin to unshielded UVC Lamp.  
2. CAUTION: The UVC Lamp may shatter and cause  
injury if it is dropped or sustains impact. Wear safety  
glasses and gloves when handling the UVC Lamp.  
Do not use excessive force when handling the UVC  
Lamp. Dispose of the UVC bulb in accordance with  
local or State guidelines as trace amounts of Mercury  
are present.  
©2010 Hunter Fan Co.  
3
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
3. This Air Purifier is designed for use on a level floor and  
may not work properly on an uneven floor. ALWAYS  
place the Air Purifier on a firm, level floor. ALWAYS  
place the Air Purifier at least six (6) inches away from  
walls and heat sources such as stoves, radiators, or  
heaters.  
4. Place the Air Purifier in an area that is out of the reach  
of children.  
5. Before using the Air Purifier, extend the cord and  
inspect for any signs of damage. DO NOT use the  
product if the cord has been damaged.  
6. To reduce the risk of electric shock, this product has  
a polarized plug (one blade is wider than the other)  
as a safety feature. This plug will fit into a polarized  
outlet only one way. If the plug does not fit fully into  
the outlet, reverse the plug. If it still does not fit, contact  
a qualified electrician. DO NOT attempt to defeat or  
override this safety feature.  
7. ALWAYS UNPLUG the Air Purifier while it is being  
cleaned.  
8. DO NOT move or tilt the Air Purifier while it is in  
operation. Turn off and unplug before moving.  
9. DO NOT immerse the Air Purifier in water at any time  
because permanent damage will occur. To properly  
clean your Air Purifier, follow the instructions in the  
Maintenance section of this manual “Air Purifier  
10. This equipment should be inspected frequently and  
collected dirt removed from it regularly to prevent  
excessive accumulation that could result in flashover  
or risk of fire.  
©2010 Hunter Fan Co.  
4
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
seTTIng up your aIr purIfIer  
1. Take the Air Purifier out of the box and remove the  
clear plastic protective bag and place the unit on a  
firm, level surface.  
Tab  
2. Before turning on the Air Purifier, you need to confirm  
that the filters are firmly in place and have not become  
loose during shipping. To check the filters, push down  
on the tab under the handle. Figure 1.  
3. Gently pull the rear grill away from the unit and lift  
away. Figure 2.  
figure 1.  
4. The washable Pre-Filter is mounted inside the back  
grill of the unit. Confirm that it properly covers the  
grill vents.  
5. The Permanent HEPA Filter will be resting inside the  
unit. If present, remove the plastic bag surrounding  
the filter and place the filter back into the Air Purifier.  
The filter should have arrows on the side to indicate  
air flow and the direction the filter should be placed  
back into the unit. Figure 3.  
figure 2.  
6. Set the tab on the bottom of the rear grill into the slot  
in the base of the unit and rock the grill up until the  
top tab snaps into place. Figure 4.  
7. Plug the unit into a 120V electrical outlet.  
Permanent  
HEPA Filter  
figure 3.  
figure 4.  
©2010 Hunter Fan Co.  
5
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
How THe sysTem works  
Dust and other irritants are pulled into the Air Purifier by the fan. The Washable Pre-  
Filter attracts larger particles like pet dander, hair and traps them on the Pre-Filter. Smaller  
particles such as dust, mold, and pollen pass through the Pre-Filter and are captured by the  
Permanent HEPA filter. Up to 99.9% of particles can be captured.  
The UVC Light helps kill particles not trapped on the Permanent HEPA Filter and the  
Photocatalytic Oxidation screen removes harmful VOCs. Clean, purified air is then released  
into the room through the front grill as the Oxygenating Catalyst converts smog and ozone  
back into oxygen. Figure 5.  
Unit  
Photocatalytic  
Oxidizer  
Grill  
Washable  
Pre-Filter  
Permanent  
HEPA Filter  
UVC  
Light  
Oxygenating  
Catalyst  
figure 5.  
©2010 Hunter Fan Co.  
6
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
UVC ON/OFF  
operaTIng your aIr purIfIer  
UVC  
Indicator  
OFF  
Unit off  
Speed  
control  
ON/OFF  
Low speed - Recommended for use when soft  
background noise is unwanted.  
Medium speed - Typical usage setting. Soft  
background noise is not an issue.  
ON/OFF  
Indicator  
High speed - Use when quick, efficient results  
to a rooms air quality are desired.  
figure 6.  
The fan speed can be adjusted at any time by rotating the  
dial so the indicator light aligns with the desired speed.  
Press the UVC Light Button to turn on and off the UVC  
function of your Air Purifier.  
NOTE: The ON/OFF Indicator and the UVC Indicator  
will stay lit while the fan and/or UVC is running.  
aIr purIfIer maInTenanCe  
It is necessary to periodically check your Air Purifier for  
performance. If the Pre-Filter and/or Permanent HEPA  
Filter are covered in dust and other captured particles, it  
will be necessary to clean one and or both. The Pre-Filter  
and Filter should be checked at least every 6 months. The  
UVC Light should be replaced every year.  
Press  
Down  
NOTE: Some environments may require more frequent  
cleaning of each filter. In these situations, adjust the time  
you check your filters to ensure the filters stay clog free to  
optimize performance.  
figure 7.  
Check or Clean your pre-filter  
1. Turn the Air Purifier off and disconnect from the wall.  
2. Remove the rear grill on the back of the unit by  
pressing the tab at the top of the unit, under the  
handle and pull the rear grill outward. Figure 7.  
3. Turn the Rear grill over and gently remove the Pre-  
Filter from the grill.  
4. Check the Pre-Filter side facing the grill for particle  
coverage.  
©2010 Hunter Fan Co.  
7
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. If the Pre-Filter needs to be cleaned, It may be  
submerged in warm soapy water to clean. Gently lift  
and submerge the filter several times to clean.  
6. When complete, rinse the filter with warm water and  
allow to dry completely.  
Note: Wet parts placed into the unit can cause damage  
to the filters and or the motor of the Air Purifier.  
Check or Clean your filter  
1. Turn the Air Purifier off and disconnect from the wall.  
figure 8.  
2. Remove the rear grill on the back of the unit by  
pressing the tab at the top of the unit, under the  
handle and pull the rear grill outward. Figure 7.  
Screws  
3. Remove the Permanent HEPA Filter from the unit.  
4. Check the Filter for particle build-up.  
5. To clean, use a vacuum cleaner with an upholstery  
brush attachment, gently run the upholstery brush  
over the cleanable filter until all particles are removed  
from the filter. An arrow indicating which side to clean  
is present on the top of the filter. Figure 8.  
Tab  
figure 9.  
Note: Filter discoloration is normal and will not be  
removed by vacuuming. Do not attempt to wash the filter  
as damage to the filter or Air Purifier may occur.  
replace The uVC bulb  
The UVC light should be replaced once yearly. Follow  
these instructions to remove and replace the UVC bulb.  
1. Unplug the unit from the wall outlet and turn it over, so  
the bottom of the unit is visible.  
figure 10.  
2. Using a small phillips screwdriver remove the 2 screws  
holding the UVC Cover in place. Figure 9.  
3. Gently push the tab on the UVC Cover and lift it away.  
Figures 9. and 10.  
4. Locate the UVC Bulb Carrier and turn it 45o counter-  
clockwise. Figure 11.  
figure 11.  
©2010 Hunter Fan Co.  
8
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
   
5. Lift the UVC Bulb Carrier out of the unit. Figure 12.  
6. Unscrew the UVC Bulb From the carrier and dispose  
of the UVC bulb in accordance with local or State  
guidelines as trace amounts of Mercury are present.  
7. Partially remove the new UVC Bulb from its packaging  
being careful not to let the bulb come in contact with  
your skin.  
Note: Oils from your skin can cause damage to the bulb  
and will prevent it from working.  
figure 12.  
8. Using the bag the bulb came in to prevent skin contact  
with the bulb, screw the bulb into the Carrier socket.  
Figure 13. Do not over tighten. Discard the bag.  
9. Reinsert the Bulb carrier into the unit at a 45o angle  
and turn clockwise to lock into the Air Purifier.  
Note: If the UVC Bulb door is not re-installed correctly,  
the unit will not run.  
10. Reattach the UVC cover by inserting the back tabs  
into the Air Purifier and snapping the tab back into  
place. Figure 14.  
figure 13.  
11. Reinsert the 2 screws securing the UVC Cover into  
place. Refer to Figure 9.  
Clean the unit  
Clean the outside of the unit with a soft, damp cloth.  
The rear grill can be cleaned in soapy water after it has  
been removed from the unit and the pre-filter has been  
removed.  
NOTE: Ensure the grill is completely dry before  
reinstalling it on the unit. Failure to do so could cause  
damage to the filters or motor.  
Tabs  
figure 14.  
©2010 Hunter Fan Co.  
9
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
TroublesHooTIng  
Problem:  
Solution:  
No Operation.  
3 Confirm that the unit is plugged in.  
3 Check the installation of the Rear grill.  
3 Check the installation of the UVC Lamp Cover.  
Problem:  
Unit has reduced air flow or increased noise.  
Solution:  
3 The filter may be clogged and needs to be  
cleaned. See “Check or Clean Your Filter” on  
page 10.  
Problem:  
The UVC Lamp is not operating.  
Solution:  
3 Check the installation of the UVC Bulb.  
3 Replace the UVC Bulb. See “Replace The UVC Bulb”  
TeCHnICal supporT  
If you have any additional questions or problems with  
your Hunter Air Purifier, please call:  
USA: 1-888-830-1326  
Canada: 1-866-268-1936  
Hours of operation are from 7:00 am to 7:00 pm  
Monday - Friday and 8:00 am to 5:00 pm on Saturday,  
Central Time. You may also contact us over the Internet at  
©2010 Hunter Fan Co.  
10  
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
fIlTer orderIng  
produCTs  
Your Permanent HEPA filter and Washable pre-filters  
should never need to be replaced. Follow the cleaning  
instructions in this manual for care.  
Ceiling Fans  
Replacement UVC bulbs are available from the Hunter  
Fan Company by contacting us at:  
Humidifiers  
Air Purifiers  
Phone: 1-888-830-1326  
* Applicable state and local taxes may apply.  
* Prices are subject to change without notice.  
All orders will be shipped USPS or UPS Ground, allow  
12-15 working days for delivery.  
part#  
Type  
30850  
uVC bulb  
warranTy  
Thermostats  
Bath Fans  
Hunter Fan Company  
Total Air Purification System  
5 YEAR LIMITED WARRANTY  
The Hunter Fan Company makes the following limited  
warranty to the original residential user or consumer  
purchaser of the Total Air Purification System:  
If any part of your Total Air Purification System (“Air  
Purifier”) motor fails during the first five (5) years from  
the date of installation due to a defect in material or  
workmanship, we will provide a replacement Air Purifier  
free of charge. Installation is deemed to occur at the date  
of purchase.  
If the Air Purifier cord, ionizer, or rear grill fails any  
time within one (1) year after installation due to a defect  
in material or workmanship, we will replace or, at our  
option, repair the unit free of charge at our nearest  
service center or at our Service Department in Memphis,  
Tennessee. You will be responsible for all parts and labor  
costs after this one-year period.  
Oscillating Fans  
©2010 Hunter Fan Co.  
11  
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 
IF THE ORIGINAL RESIDENTIAL USER OR CONSUMER  
PURCHASER CEASES TO OWN THE AIR PURIFIER,  
THIS WARRANTY AND ANY IMPLIED WARRANTY  
WHICH THEN REMAINS IN EFFECT, INCLUDING  
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE, ARE VOIDED. NO WARRANTY, EXPRESSED  
OR IMPLIED, INCLUDING ANY WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE, IS MADE IN RESPECT TO THE FILTER  
MATERIAL OR Washable FILTER. THIS WARRANTY IS  
IN LIEU OF ALL OTHER EXPRESS WARRANTIES. THE  
DURATION OF ANY IMPLIED WARRANTY, INCLUDING  
BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF  
MERCHANTABILITY OR FITNESS FOR A PARTICULAR  
PURPOSE, IN RESPECT TO THE MOTOR IS EXPRESSLY  
LIMITED TO THE PERIOD OF THE EXPRESS WARRANTY  
SET FORTH ABOVE.  
This warranty is voided if the air purifier is not purchased  
and used in the USA or Canada.  
This warranty excludes and does not cover defects,  
malfunctions or failures of the Air Purifier which were  
caused by repairs by persons not authorized by us, use of  
parts or accessories not authorized by us, mishandling,  
modifications, or damage to the Air Purifier while in  
your possession, or unreasonable use, including failure  
to provide reasonable and necessary maintenance. This  
warranty does not cover Air Purifiers used in commercial  
applications. There are no express or implied warranties  
as to commercial purchasers or users.  
To obtain service, contact the nearest Hunter authorized  
service center or the Hunter Fan Company Service  
Department, 7130 Goodlett Farms Pkwy., Suite 400,  
Memphis, TN 38016, 1-888-830-1326. For the name  
of our nearest authorized Hunter Fan Company Service  
Center, write to the Hunter Fan Company at the preceding  
address. You will be responsible for insurance and freight  
or other transportation to our factory service center. We  
will return the Air Purifier freight prepaid. The Air Purifier  
should be properly packaged to avoid damage in transit  
since we will not be responsible for any such damage.  
Proof of purchase is required when requesting warranty  
service. The purchaser must present sales receipt or other  
document that establishes proof of purchase.  
©2010 Hunter Fan Co.  
12  
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INNOEVENTSHALLHUNTERFANCOMPANYBELIABLE  
FOR DIRECT, INDIRECT, SPECIAL CONSEQUENTIAL OR  
INCIDENTAL DAMAGES IN EXCESS OF THE PURCHASE  
PRICE OF THE AIR PURIFIER. YOUR SOLE REMEDY  
WILL BE REPAIR OR REPLACEMENT AS PROVIDED  
ABOVE. SOME AMERICAN STATES AND CANADIAN  
PROVINCES DO NOT ALLOW LIMITATIONS ON HOW  
LONG AN IMPLIED WARRANTY LASTS, SO THE ABOVE  
LIMITATION MAY NOT APPLY TO YOU.  
SOME AMERICAN STATES AND CANADIAN  
PROVINCES DO NOT ALLOW THE EXCLUSION  
OR LIMITATION OF DIRECT, INDIRECT SPECIAL,  
INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO THE  
ABOVE LIMITATION MAY NOT APPLY TO YOU. SOME  
AMERICAN STATES AND CANADIAN PROVINCES  
DO NOT ALLOW THE EXCLUSION OR INVALIDITY  
OF EXPRESS OR IMPLIED WARRANTIES IF THE USER  
CEASES TO OWN THE AIR PURIFIER, SO THE ABOVE  
LIMITATION MAY NOT APPLY TO YOU.  
THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS,  
AND YOU MAY ALSO HAVE OTHER RIGHTS WHICH  
VARY FROM STATE TO STATE OR PROVINCE TO  
PROVINCE.  
Company  
7130 Goodlett Farms Pkwy., Suite 400  
Memphis, Tennessee 38016  
To learn more about Hunter  
Fan Company products,  
please see our Web page at:  
www.hunterfan.com  
©2010 Hunter Fan Co.  
13  
44024-01 20100616  
Download from Www.Somanuals.com. All Manuals Search And Download.  
fIlTer and uVC Calendar  
noTes  
Date of Replacement or Cleaning  
Pre-Filter  
Perma Filter  
UVC Bulb  
Printed in china and Taiwan  
44024-01 20100616  
©2010 Hunter Fan Co.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
 

Grandstream Networks Network Card HandyTone 386 User Manual
Grizzly Impact Driver h6140 User Manual
Haier Refrigerator HDE03WNA User Manual
Haier Refrigerator PBFS21EDAE U User Manual
HANNspree Flat Panel Television ST32 15H1 User Manual
Havis Shields Work Light CD QS 1 User Manual
Hotpoint Range EG54 User Manual
Hotpoint Range RB530WCWW User Manual
Husqvarna Lawn Mower YTH2548XP User Manual
IBM Printer 600 1200 Series User Manual