Hoshizaki America, Inc.
Hoshizaki
Commercial Refrigerators & Freezers
Undercounter & Worktop Series
Models
Refrigerators
HUR40A(-D) HWR40A(-D)
HUR68A(-D) HWR68A(-D)
HUR96A(-D) HWR96A(-D)
Freezers
HUF40A(-D) HWF40A(-D)
HUF68A(-D) HWF68A(-D)
INSTRUCTION MANUAL
“A Superior Degree
of Reliability”
Issued: 6-24-2003
Revised: 7-8-2005
Download from Www.Somanuals.com. All Manuals Search And Download.
• Please review this manual. It should be read carefully before the unit is installed and
operated. Only qualified service technicians should install, service and maintain the unit.
This manual should be made available to the technician prior to installation, maintenance
or service.
• Keep this manual with the unit for later reference.
CONTENTS
I. Installation Instructions ...................................................................................................... 5
A. Unpacking and Checks Before Installation .................................................................. 5
B. Opening and Removing the Front Panel ...................................................................... 6
C. Moving the Unit in a Narrow Elevator or Hallway......................................................... 6
D. Location ....................................................................................................................... 7
E. Setup............................................................................................................................ 7
F. Electrical Connection.................................................................................................... 8
G. Drain Connection......................................................................................................... 9
H. Final Checklist ............................................................................................................. 9
II. Operating Instructions ..................................................................................................... 10
A. Operation - For Safety and Best Results .................................................................... 10
B. Startup ....................................................................................................................... 11
C. Food Storage ............................................................................................................. 12
D. Shutdown ................................................................................................................... 12
E. Electronic Control Operation ...................................................................................... 13
1. Temperature Display............................................................................................. 13
2. Adjusting the Setpoint Temperature ...................................................................... 14
3. Alarm Codes......................................................................................................... 14
4. Defrost .................................................................................................................. 14
5. Start-up Delay ...................................................................................................... 15
6. Compressor Short Cycle Timer ............................................................................ 15
7. Safety Devices...................................................................................................... 15
a) Pressure Switch ................................................................................................ 15
b) Compressor Protector........................................................................................ 15
c) Defrost Protection .............................................................................................. 15
8. Energy Saving Mode ............................................................................................ 15
F. Troubleshooting .......................................................................................................... 16
1. Unit Fails to Operate ............................................................................................. 16
2. Alarm Code Appears in Display ........................................................................... 17
3. Poor Cooling Performance.................................................................................... 18
4. Condensation ....................................................................................................... 18
5. Noise .................................................................................................................... 18
III. Cleaning and Maintenance Instructions ......................................................................... 19
A. Cleaning .................................................................................................................... 19
1. Exterior ................................................................................................................. 19
2. Interior .................................................................................................................. 19
3. Door/Drawer Gaskets ........................................................................................... 19
4. Shelves ................................................................................................................ 20
5. Air Filter ................................................................................................................ 20
6. Condenser............................................................................................................ 20
7. Drawers ................................................................................................................ 20
3
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Maintenance .............................................................................................................. 20
1. Air Filter ................................................................................................................ 20
2. Power Supply Connection .................................................................................... 21
3. Other..................................................................................................................... 21
4
Download from Www.Somanuals.com. All Manuals Search And Download.
I. Installation Instructions
A. Unpacking and Checks Before Installation
CAUTION
Unit is heavy. Use care when lifting or positioning. Work in pairs when needed to
prevent injury to persons lifting and to prevent damage to the unit. Hold the
bottom of the unit. Do not hold doors/drawers; they could become deformed or
come off. Do not tilt the unit by more than 45°.
1) All tape and packaging should be removed from the machine prior to installation. The
equipment should be inspected for any damage which may have occurred during
shipment. Concealed damage claims must be filed with the carrier.
a) Visually check that the refrigerant lines do not rub or touch other lines or surfaces and
that the fan blades turn freely.
b) Check that the compressor is snug on all mounting pads.
2) Remove all accessory containers before discarding the packing materials. Dispose of all
packing materials in a proper and environmentally responsible manner.
3) Check for missing or damaged accessories.
4) To remove the unit from the pallet:
a) Move as close to the final location as possible.
b) Remove the bolts that secure the cabinet to the pallet.
c) Block the cabinet securely, at a height of 8 inches (203 mm) off the floor.
d) Attach the casters or adjustable legs to the bottom of the cabinet as necessary.
5) Remove the protective plastic film from the exterior and interior. If the unit has been
exposed to the sun or to heat, remove the film after the unit cools.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
B. Opening and Removing the Front Panel
1) Grip outer edge of the front panel near the bottom and top and pull open approximately
1/2 inch (13 mm) until it is disengaged.
2) Swing the panel open completely and lift up approximately 1/2 inch (13 mm) to remove
completely.
C. Moving the Unit in a Narrow Elevator or Hallway
Hoshizaki undercounter and worktop models have a cartridge type (removable) refrigeration
unit. When the space in an elevator or hallway is limited, the unit can be carried as follows:
1) Turn off the power supply, and unplug the unit.
Refrigeration Unit
2) Remove the front panel, then remove the
wire guard located below the display
panel.
3) Unhook the wiring connectors at the control
box, then remove the two hex-head M6
attachment nuts and the M5 bolt.
4) Very carefully slide out the refrigeration
unit. Support the evaporator as it clears the
evaporator case. Be careful not to damage
the refrigeration circuit tubing.
Front Panel
5) After taking out the refrigeration unit, secure the doors/drawers with tape.
Note: Remove all accessories from inside the ca
6) Place the unit upright on a cart, and roll it
into the elevator.
Tape
7) Carry the unit to the installation site. Refit
the removed parts in the reverse order of
which they were removed.
Note:
• Before placing the unit upright on a
cart, lay a cloth on the cart to protect
the unit from damage.
• When standing or carrying the unit, be
sure to work in pairs.
Cloth
WARNING
The installation must be carried out by qualified personnel in accordance with
this Instruction Manual. Improper installation may cause water leak, electric
shock or fire. After the installation, make a trial run to check for proper operation
and instruct the user on how to use and maintain the unit according to the
Instruction Manual.
6
Download from Www.Somanuals.com. All Manuals Search And Download.
D. Location
CAUTION
This unit is not intended for outdoor installation. The air temperature should be
within a 45°F (7°C) to 100°F (38°C) range. Extended periods of operation at
temperatures exceeding these limitations may cause unsatisfactory results.
For best operating results:
• The machine should be on a flat, level and solid (firm) foundation.
• The unit should not be located in a corrosive environment.
• The air temperature range at the location should be between 45°F (7°C) and 100°F (38°C).
• The unit should not be near ovens, grills, other high heat producing equipment or in direct
sunlight.
• The unit may be safely installed and operated flush with walls, but for maximum
performance, install a minimum of 4 inches (102 mm) from all walls.
• Allow at least 20 inches (50 cm) at the front for proper air circulation.
E. Setup
1) Position the unit in the selected location. For units with casters, no adjustment is
necessary. Units with legs can be levelled in both the front-to-back and side-to-side
directions. The feet are provided with hex flats in order to facilitate adjustment. Viewed
from the bottom, turn clockwise to lower each leg and counterclockwise to raise each
leg.
2) Install the shelves using the shelf support clips provided in the accessory pack. Shelves
are adjustable in one inch increments. Adjust to the height of stored items.
IMPORTANT
1. Casters must be installed flush to unit. If floor irregularity requires adjustment
of caster height, add caster shims as necessary (provided with unit) and
retighten casters completely.
2. Attach the shelf clips properly to make shelves level.
3. Slant shelves when placing into cabinet in order to clear door frame opening.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
F. Electrical Connection
Cord-connected units should only be plugged into a 115 volt, 60 Hz circuit with a national
and local electrical code approved, grounded wall receptacle. A separate circuit with its
own circuit breaker (HACR type) or fuse (LP-CC type) should be provided. Refer to the
nameplate, located inside the cabinet, for the proper electrical specifications.
Hardwired units should only be wired into the proper conduit, with its own circuit breaker
(HACR type) or fuse (LP-CC type). Refer to the nameplate for the proper electrical
specifications.
WARNING
1. Make sure the power switch is off before making electrical connections to
prevent possible electric shock.
2. The connections must be made to a separate power supply or receptacle in
accordance with the national and local electrical code requirements and this
Instruction Manual. Branching off the power cord, using an extension cord, or
sharing a single power supply with other appliances may result in electric
shock, heat generation or fire.
3. This unit should be disassembled or repaired only by qualified service
personnel to prevent the risk of electric shock or fire.
4. Do not make any alterations to the unit. Alterations could result in water leak,
electric shock or fire.
5. Do not damage the power cord. It should not be altered, jerked, bundled,
weighed down, pinched, or tangled. Such actions could result in electric
shock or fire.
6. To prevent electric shock, do not touch the attachment plug, power switch, or
other electrical parts with damp hands.
7. Failure to use a proper breaker or fuse can result in a tripped breaker, blown
fuses or damage to existing wiring.
CAUTION
1. To unplug the unit, be sure to pull the attachment plug and do not jerk the
power cord. It could be damaged and cause fire or electric shock.
2. The maximum allowable voltage variation should not exceed 10% of the
rated voltage. Operation outside of this range may result in failure or
reduction of refrigeration performance.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
G. Drain Connection
This unit is provided with an energy efficient automatic condensate water disposal
system and normally requires no drain connection.
H. Final Checklist
1) Is the unit level?
2) Is the unit located in a site where the ambient temperature will be within the
45°F to 100°F (7°C to 38°C) range—year round?
3) Have all shipping cartons, tapes and packing materials been removed from the unit?
4) Has the power supply been checked or tested against the nameplate rating?
5) Has the unit been checked for shipping damage?
6) Has the Owner's Warranty Registration been filled out and forwarded to the factory?
9
Download from Www.Somanuals.com. All Manuals Search And Download.
II. Operating Instructions
A. Operation - For Safety and Best Results
IMPORTANT
1. Do not leave the doors/drawers open.
2. Open and close the doors/drawers with care. Doors/drawers opened too
quickly or forcefully may cause injury or damage to the unit or surrounding
equipment. Doors/drawers may be hard to open just after they have been
closed. Try again after 15 seconds.
3. To prevent deformation or cracks, do not spray insecticide onto the plastic
parts or let them come into contact with oil.
4. This unit is designed only for temporary storage of food. Employ sanitary
methods. Use for any other purposes (for example, storage of chemicals or
medical supplies such as vaccine and serum) could cause deterioration of
stored items.
5. To avoid damage to the gasket, use only the door/drawer handle (do not grab
the top of the door/drawer directly) when opening and closing.
WARNING
For All Units
1. If the unit does not work properly, turn OFF the power switch and unplug the
unit or disconnect the main power source, then contact an authorized
Hoshizaki service company. To prevent possible electric shock or fire, do not
keep the unit in operation.
2. Do not hang on or push down on the doors/drawers. The doors/drawers might
be damaged, fall off, or the unit could tip over, causing injury.
3. To prevent electric shock, do not touch the attachment plug, power switch or
other electrical parts with damp hands.
4. Do not store any volatile or flammable substances, such as benzine, ether,
alcohol, adhesives, or LPG in the unit. They are potential sources of
explosion or fire.
5. Do not throw anything onto the shelves or load any single shelf with more
than 120 lb (54.5 kg) of product. They might fall off and cause injury.
6. Do not store food or food containers near the air outlet. They might freeze up
and crack or break causing a risk of injury or contamination of other food.
7. Do not use combustible spray or place volatile and flammable substances
near the unit. They might catch fire.
8. Do not put anything into the machine compartment or the condenser air inlet/
outlet. The fan rotating rapidly inside might cause injury or heat.
10
Download from Www.Somanuals.com. All Manuals Search And Download.
WARNING
Additional Warning For Units with Drawers
1. Do not hang on or push down on the drawers, and do not load any single
drawer with more than 150 lb (68 kg) of product.
2. Depending on the weight of product in the drawers, secure the unit as
necessary to prevent it from overturning.
3. Do not open more than one drawer at a time and never stand on the drawers.
B. Startup
WARNING
Do not splash water directly onto the unit. It may cause short circuit, electric
shock, corrosion or failure.
CAUTION
Do not put anything into the air inlet/outlet. The fan rotating rapidly inside may
cause injury.
After installation, wipe the interior with a soft cloth containing cold or warm water.
This unit is equipped with an electronic control which has been preset at the factory to
maintain a specified cabinet storage temperature. After the power cord is plugged securely
into the closest outlet off the floor, open the front panel for access to the power switch—
located on the control box front—and turn the switch on.
IMPORTANT
There is a 2 minute normal delay before the refrigeration system starts.
Allow the unit to pull down and start cycling on the controller prior to loading it with food
products. For more information on electronic control operation, see section E.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
C. Food Storage
• Do not block the air inlet and outlet with food, or cooling performance may be reduced.
• If the cabinet temperature is set to maintain a subfreezing temperature, do not store
vegetables or any foods that should not be frozen, or these foods may deteriorate.
• Do not tightly pack the cabinet with food. Allow some space between items/containers to
ensure good air flow. Also allow space between food product and interior surfaces.
• Do not put warm or hot foods in the unit. Let them cool first, or they will raise the cabinet
temperature and could deteriorate other foods in the cabinet or overload the refrigerator.
• All foods should be wrapped in plastic film or packed in a container. Otherwise foods may
dry up, pass their smells onto other foods, cause frost to develop, result in poor unit
performance, or increase the likelihood of cross-contamination. Certain dressings and
food ingredients, if not stored in containers, may accelerate corrosion of the evaporator,
resulting in failure.
D. Shutdown
WARNING
1. When preparing the unit for long storage, prevent the doors/drawers from
closing tightly to reduce the risk of children getting trapped.
2. To prevent electric shock, do not touch the attachment plug, power switch or
other electrical parts with damp hands.
3. To unplug the unit, be sure to pull the attachment plug and do not jerk the
power cord. It could be damaged and cause fire or electric shock.
4. When shutting down the unit for more than one week, turn OFF the power
switch and unplug the unit.
5. Do not plug in/unplug the unit to start/stop operation. This could cause
electric shock or short circuit.
1) Before shutting down the unit, move the stored food into another refrigerator/freezer.
2) Open the front panel and turn the power switch to OFF. The unit will shut down.
3) Unplug the unit or disconnect the main power source.
4) Close the front panel.
IMPORTANT
When preparing the unit for long storage, clean the cabinet liner, shelves and
door/drawer gaskets.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
E. Electronic Control Operation
The display panel is located on the face of the refrigeration circuit, behind the front panel.
Upon opening the front panel, the display panel can be accessed. From the display panel,
various controls and functions can be adjusted. Follow the instructions and warnings below
and on the display panel for safe and efficient operation of the unit.
1. Temperature Display
The factory setting is °F. To change the display to °C, follow the steps below.
1) Press and hold both the
button and the
unmarked, blank button for 5 seconds.
“F5” appears in the display window. (If “F0” is displayed, press the MANUAL DEFROST
button repeatedly until “F5” appears.)
2) Press the
the up or
again to save the setting.
unmarked, blank button to display the current setting (default: “F”). Press
down button to switch to °C. Press the unmarked, blank button
13
Download from Www.Somanuals.com. All Manuals Search And Download.
3) Press and hold both the
button and the
unmarked, blank button for 5 seconds.
The cabinet temperature will be displayed using the newly saved temperature scale.
4) Affix the “°C” label supplied with the unit to the display panel, covering “°F” but not the
display window.
Note: The cabinet temperature is updated every 30 seconds.
2. Adjusting the Setpoint Temperature
The setpoint temperature is the temperature at which the compressor turns on. To set the
setpoint temperature, follow the steps below.
1) Press the
button to display the current setpoint temperature.
2) To change the setpoint, press and hold the
down button to raise or lower the setpoint.
button while pressing the
up or
Allowable Setpoint Range
Default
Fahrenheit
Celsius
Fahrenheit
Celsius
Freezer
(Door Unit)
Freezer
-13 to +19°F -25 to -7°C
0°F
-18°C
-13 to +19°F -25 to -7°C
2°F
-17°C
4°C
(Drawer Unit)
Refrigerator
(auxiliary
code Q5 and
before)
Refrigerator
(auxiliary
code Q6 and
later)
39°F
+21 to +53°F -6 to +12°C
37°F
3°C
3) After 10 seconds, the new setpoint will be saved automatically.
Note: For freezers with doors, the temperature differential for the compressor to turn off is
6.3°F (3.5°C) below the setpoint. For freezers with drawers, the temperature
differential for the compressor to turn off is 3.6°F (2.0°C) below the setpoint. For
refrigerators, it is 4.5°F (2.5°C) below the setpoint for auxiliary code Q5 and before
and 3.6°F (2.0°C) below the setpoint for auxiliary code Q6 and later.
3. Alarm Codes
See the troubleshooting section for an explanation of the alarm codes.
4. Defrost
This unit is preset at the factory to defrost every 6 hours for general conditions, the first
defrost occurring 6 hours after power to the unit is turned on. Note that the defrost is a
heated defrost, and therefore will have a tendency to raise the cabinet temperature.
Cabinet temperature is not displayed during defrost; “dF” is displayed in its place. Defrost
may be initiated manually by holding down the MANUAL DEFROST button for
5 seconds.
14
Download from Www.Somanuals.com. All Manuals Search And Download.
5. Start-up Delay
The start circuit of the compressor is timed such that at power-up and during any
compressor off-time, there will be at least a 2 minute delay before the compressor will
start.
6. Compressor Short Cycle Timer
There is a 2 minute minimum off-time and on-time for the compressor.
Note:
• Any time the compressor is started, it will keep running for a minimum of 2 minutes.
• Any time the compressor is turned off, it will stay off for a minimum of 2 minutes.
• Time may vary with pressure switch activation.
7. Safety Devices
a) Pressure Switch
When pressure on the high-side of the unit is detected to be above a preset limit
(determined by Hoshizaki specifications), a pressure switch will activate causing power
to be interrupted to the compressor relay. This power interruption will shut down the
compressor for a minimum of 5 minutes. After 5 minutes, if pressure is no longer above
the preset limit, the pressure switch will reset automatically. When the pressure switch
resets, power will be resupplied to the compressor.
b) Compressor Protector
When a combined temperature/amperage value is above the limit specified by the
compressor manufacturer, a protector will operate independently, turning off the
compressor. The compressor will restart when this protector has reset.
Note:
• The compressor protector resets automatically.
• If the condenser fan is operating and the compressor is off, it is most likely that the
protector has operated.
c) Defrost Protection
Primary defrost termination is controlled by the defrost thermistor. However, two
additional safeties are also present.
1. Time Termination - 1 hour maximum
2. Temperature Termination - Measured by a separate device that is in-line with the
heaters and independent of the control board.
8. Energy Saving Mode
On some units, the evaporator fan and/or other components may operate intermittently as
a means to reduce energy consumption. This setting is made at the factory and such
operation is automatic.
15
Download from Www.Somanuals.com. All Manuals Search And Download.
F. Troubleshooting
WARNING
1. If the unit does not work properly, turn OFF the power switch and unplug the
unit or disconnect the main power source, and immediately contact an
authorized Hoshizaki service company. To prevent possible electric shock or
fire, do not keep the unit in operation.
2. This unit should be disassembled or repaired only by qualified service
personnel to prevent the risk of injury, electric shock or fire.
3. Do not make any alterations to the unit. This could cause water leak, electric
shock or fire.
4. To prevent electric shock, do not touch the attachment plug, power switch, or
other electrical parts with damp hands.
IMPORTANT
1. In case of insufficient refrigeration performance, move the stored food product
into another unit to prevent its deterioration.
2. When contacting a service company, let them know the model name, serial
number, date of installation (see warranty card) and the nature of the trouble
(errorcode, etc.).
1. Unit Fails to Operate
• Power failure. Wait until power supply is resumed.
• Unplugged. Plug in.
16
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Alarm Code Appears in Display
If an error occurs, the alarm code and cabinet temperature are displayed in 1-second
intervals. When an error occurs, check the error code and follow the instructions below. If
more than one abnormal condition exists, alarm codes will be displayed in order of
priority.
Alarm Signals
Alarm Code Problem
High Temperature Alarm
Notes
When temperature returns to setpoint range,
alarm code “E1” will clear.
Cabinet temperature has exceeded set
temperature by 18°F (10°C) for more than x
minutes. The default value of x is "2" (120
minutes).
E1
If temperature is not back in range, and obvious
corrections do not bring temperature back in
range, call a qualified service technician.
Low Temperature Alarm
When temperature returns to setpoint range,
alarm code “E2” will clear.
Cabinet temperature has remained below
setpoint by 9°F (5°C) for more than y minutes. If temperature is not back in range, and obvious
The default value of y is "1" (60 minutes).
E2
E3
corrections do not bring temperature back in
range, call a qualified service technician.
Defrost Alarm
Call a qualified service technician.
Defrost has taken longer than 1 hour. Control
board has terminated defrost.
Note that E3 may alternate with "dF" instead of
the temperature.
High Pressure Alarm
Clean filter if necessary. Allow time for pressure
switch to react, then turn power off and back on
again to reset.
Compressor discharge pressure is outside
normal operating range. Pressure switch has
been triggered 5 or more times in 1 hour.
Condenser filter may need cleaning.
E4
E7
If switch trips 5 times in 1 hour, and the above
steps do not clear the alarm code, call a
qualified service technician.
Clogged Filter Alarm
Clean filter. Allow time for sensor to react, then
turn power off and back on again to reset.
Condenser temperature is outside of normal
operating range. Condenser filter needs
cleaning.
If this alarm occurs frequently, it is
recommended that a qualified service technician
be called.
Defrost Temperature Sensor Malfunction Alarm Call a qualified service technician. After
replacing sensor, alarm will reset.
Defrost temperature sensor has failed.
E8
E9
EA
ED
Clogged Filter Sensor Malfunction Alarm
Call a qualified service technician. After
replacing sensor, alarm will reset.
Clogged filter sensor has failed.
EEPROM Write Error Alarm
Call a qualified service technician.
Call a qualified service technician.
Control board is defective.
EEPROM Verification or Read Error Alarm
Control board is defective.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
3. Poor Cooling Performance
• Door(s)/drawers opened too often.
• Door(s)/drawer left open. Close.
• Too packed with food or air inlet/outlet blocked. Allow some space between items/
containers to ensure good air flow.
• Warm or hot foods inside. Take them out until they cool down more.
• Ambient temperature too high. Avoid installation near high heat producing equipment or
exposure to direct sunlight.
• Cabinet temperature setting too high. Readjust it to a lower temperature.
• Unit in defrost process. The cabinet temperature may rise temporarily during defrost cycle,
but this will not affect the food inside.
4. Condensation
• Door(s)/drawer left open. Close.
• Ambient humidity too high. Condensation may occur on a humid or rainy day. Wipe off
occasionally.
5. Noise
• Operating sounds from compressor, condenser fan motor, or evaporator fan motor. This is
not a sign of failure.
• Installed on an unsteady floor. Contact an authorized Hoshizaki service company.
• Not leveled in the left-to-right or front-to-rear directions. Contact an authorized Hoshizaki
service company.
18
Download from Www.Somanuals.com. All Manuals Search And Download.
III. Cleaning and Maintenance Instructions
A. Cleaning
WARNING
1. Do not splash water directly onto the unit. This might cause short circuit,
electric shock, corrosion or failure.
2. When cleaning or inspecting the unit, turn OFF the Power Switch and unplug
the unit or disconnect the main power source to prevent electric shock, by
unexpected entrance of water into the unit, or injury by any moving parts.
3. To prevent frostbite, do not touch foods or containers (especially metallic) in
the freezer compartment with damp hands.
4. Before using a sanitizer such as inert soap and sodium hypochlorite,
thoroughly read the manufacturer’s instructions on the proper usage and
amount.
IMPORTANT
1. To prevent damage to the painted or plastic surfaces, do not use the
following: thinner, benzine, alcohol, petroleum, soap powder, polishing
powder, alkaline cleaner, acid, scouring pad and especially those strong
cleaners for use on a ventilating fan or a cooking range. Also, to prevent
corrosion, do not use a chlorine bleach such as sodium hypochlorite on the
stainless steel surfaces.
2. Use clean cloth and hands for cleaning.
3. Before cleaning the cabinet interior, move the stored foods into another
cleanrefrigerator/freezer.
1. Exterior
The exterior is exposed to grease, moisture and dust. Even stainless steel needs
periodic cleaning to prevent possible corrosion. Wipe the exterior occasionally with a
clean, soft cloth. Use a damp cloth containing a neutral cleaner to wipe off oil or dirt build
up. Clean the worktop as often as necessary to maintain a clean, sanitary work surface.
2. Interior
Spills should be wiped up promptly to avoid unpleasant odors. The cabinet interior
should be cleaned periodically with a mild soap or detergent.
3. Door/Drawer Gaskets
Remnants of food on the gaskets or cabinet will accelerate aging. Door/drawer gaskets
should be cleaned regularly with mild soap and water to remove dirt and grease.
19
Download from Www.Somanuals.com. All Manuals Search And Download.
4. Shelves
Remove and clean regularly.
5. Air Filter
As the air filter becomes clogged with dirt or dust, the unit’s performance will be reduced.
Do not operate the unit with the air filter removed. This will accelerate clogging of the
condenser and result in failure. Check the filter at least twice each month. If it is dirty, use
warm water and a neutral cleaner to wash the filter. To avoid damaging the air filter do not
use water hotter than 104°F (40°C). The filter is located behind the front panel. This filter
can be removed by opening the front panel and lifting the filter away from the condenser.
Reinstall the filter after cleaning.
6. Condenser
Check the condenser (located behind the air filter) once a year and use a brush or
vacuum cleaner to clean the unit as required.
7. Drawers
On units with drawers, the drawers can be removed for cleaning either individually or as
an entire assembly.
• To remove an individual drawer, first remove all food product from the drawer. Pull the
drawer out to its fully extended position and lift up on the handle to disengage the
drawer. Before removing the drawer, carefully support the rear and front of the drawer
and then slowly remove it from the cabinet.
• To remove the drawer frame assembly, first remove the drawers and then remove the
fasteners in the thermal break and in the rear of the cabinet. Carefully slide the frame
out of the cabinet, making sure not to damage the thermal break. Reinstall in the
reverse order, making sure not to overtighten the screws in the thermal break.
• To remove the drawer slide (center slide containing rollers) for cleaning, rotate the top of
the slide away from the frame while the slide is completely inside the cabinet. Drawer
slides do not require lubrication, but slides should be kept clean and free of food.
Note: Drawer slides are dishwasher safe.
B. Maintenance
1. Air Filter
The air filter promotes clean condenser surfaces and efficient unit operation by removing
dirt and grease from circulating air. The filter should be checked monthly and cleaned
when necessary—as described in “A. Cleaning - 5. Air Filter”.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
2. Power Supply Connection
WARNING
1. Check periodically that the power cord plug blades and their vicinity are free
of dust and that the plug is securely plugged into the receptacle. Dusty
blades or a loose connection may cause electric shock or fire.
2. Do not damage the power cord. It should not be altered, jerked, bundled,
weighed down, pinched, or tangled. Such actions could result in electric
shock or fire.
3. The unit must have a separate power supply or receptacle of proper capacity.
Branching off the power cord, using an extension cord, or sharing a single
power supply with other appliances may result in electric shock, heat
generation or fire.
If the plug or power cord is damaged, immediately contact an authorized Hoshizaki
service company and ask for repairs.
3. Other
All other maintenance or service on this unit should be performed in accordance with the
Hoshizaki Service Manual by a qualified service technician.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
HOSHIZAKI AMERICA, INC.
618 Hwy. 74 S., Peachtree City, GA 30269 USA TEL (770) 487-2331 FAX (770) 487-3360 www.hoshizaki.com 91A3FA10C
Download from Www.Somanuals.com. All Manuals Search And Download.
|