CT62A,B
Line Voltage Electric Heat Thermostats
Installation Instructions
CT62A provides single-line break.
CT62B provides double-line break.
Temperature Range: 50°F to 80°F (10°C to 25°C)
Electrical Ratings: 60 Hz noninductive
22A at 120-240 Vac; 19A at 277 Vac
Do-It-Yourself models
Your Honeywell Thermostat
WARNING
Your new Honeywell CT62 Electric Heating Thermostat
provides line voltage control of a radiant cable, electric
baseboard, and resistive-rated fan forced heaters within
the ratings listed above.
This thermostat is a line voltage control (120 Volts to
240 Volts.) Do not install it if you are not completely
familiar with house wiring. If handled improperly,
there can be risk of a 120 Volt to 240 Volt electric
shock hazard, which may cause serious injury or
death.
1
PREPARATION
Carefully unpack your new thermostat. To avoid
damage to the sensing element, do NOT remove
the thermostat cover until wiring has been completed.
Proper installation of your Honeywell thermostat will
occur if you follow these instructions STEP-BY-
STEP. It is recommended that as you read, understand
and complete each step, you check ꢀ it off with pencil or
pen.
Save packages of screws, instructions, receipt and
proof-of-purchase.
Check thermostat suitability for your home’s system
by reviewing the ratings listed above.
Make certain that your heating system is working,
especially if it has been inoperative for a length of
time. If the system does not work, contact your local
electrician for assistance.
3
REMOVE OLD THERMOSTAT
2 THERMOSTAT MOUNTING
DIMENSIONS
WARNING
Begin by turning off power to the heating circuit at
the main service panel.
FRONT VIEW
SIDE VIEW
Remove cover of old thermostat—cover normally
snaps off when pulled firmly from the bottom. If it
3/4
(19)
1/2 (13)
1-3/4
(48)
resists, check for a screw that locks the cover.
80
•
70
•
60
•
Loosen screws holding thermostat base to outlet
box and lift away.
50
•
˚F
2-1/8
(54)
Disconnect wires from old thermostat. As you
disconnect each wire, tape the end and label it with
the letter of the terminal designation to make reconnection
to new thermostat easier.
4-3/8
(111)
3-1/4
(83)
Check the old insulation for cracks, nicks or fraying,
and apply high quality plastic tape where necessary
for adequate insulation.
1/2 (13)
2-7/8 (73)
1-1/2
(39)
M5795A
Retain the old thermostat for reference purposes
and until your new thermostat is functioning
smoothly.
S.M. • Rev. 11-94
•
©Honeywell Inc. 1994 • Form Number 69-0829—1
Download from Www.Somanuals.com. All Manuals Search And Download.
7
TROUBLESHOOTING
Your Honeywell thermostat requires little or no attention. Most problems can generally be traced to the following:
Symptom
No heat.
Checkout
Action
Make sure power is on at
main service panel. Turn
the temperature setting
knob fully clockwise
Heater should start to warm up within two minutes. If not,
contact qualified electrician to check thermostat and heater.
.
Improper connections to
thermostat.
With power to circuit OFF, tighten all wiring connections. Repair
any frayed or broken wires.
Other.
Contact a qualified electrician for assistance.
Heater never turns
off.
Turn temperature setting
knob fully
Heater should start to cool within minutes. If not, turn off power
at the main service panel, and contact qualified electrician.
counterclockwise
.
Thermostat setting
and thermometer
reading disagree.
Thermostat affected by
drafts or radiant heat.
Contact electrician to change the location. The thermostat
should be about 5 ft (1.5m) above the floor and on an inside
wall.
Thermometer is out of
calibration.
Recalibrate. See step 8.
The heat from your hand will affect the diaphragm
sensor. Replace thermostat cover, wait five minutes
and recheck calibration.
8
CALIBRATION
The CT62 Thermostats are calibrated at the factory using
precise instruments under closely controlled conditions.
Recalibration should not be necessary. Allow the thermo-
stat to operate for several hours before checking the
calibration. The CT62 Thermostat vapor-filled dual
diaphragm sensing element is affected by barometric
pressure and altitude. Temperature deviations of 1°F
(0.5°C) are normal. If the thermostat is mounted in a
suitable location and still appears out of calibration, check
calibration as follows:
THERMOSTAT
BASE
Check Calibration
Turn the setting knob clockwise until the switch
makes (clicking sound). The heating equipment and
fan start.
No recalibration is necessary if the thermostat switch
makes with the thermostat setting at the same
temperature as indicated on the thermometer.
If the thermostat setting differs from the thermom-
eter, record the temperature difference and
recalibrate as instructed in the Recalibration Procedure
section.
SETTING KNOB
AT 12 O'CLOCK
POSITION
Recalibration Procedure
Note the temperature difference between the
temperature setting and the thermometer.
SCALE RING
Remove the thermostat cover.
Rotate setting knob clockwise
switch click.
until you hear
Hold the setting knob firmly and rotate the set point
scale ring counterclockwise until the
12 o'clock position of the ring agrees with the cover
thermometer.
SETTING KNOB
M5796
3
69-0829—1
Download from Www.Somanuals.com. All Manuals Search And Download.
Limited One-Year Warranty
Honeywell warrants this product to be free from defects in the workmanship or materials, under normal use and service, for a
period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is
defective or malfunctions, Honeywell shall repair or replace it (at Honeywell’s option) within a reasonable period of time.
If the product is defective,
(i) return it, with a bill of sale or other dated proof of purchase, to the hardware or home center store from which you
purchased it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction,
and mail it, postage prepaid, to the following address:
Honeywell Inc, RG Department
1050 Berkshire Lane
Plymouth, MN 55441-4437
in Canada: Honeywell Limited/Honeywell Limitee
740 Ellesmere Road
Scarborough, Ontario M1P 2V9
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the
defect of malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Honeywell’s sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL
NOT BE LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL
DAMAGES RESULTING, DIRECTLY OR INDIRECTLY, FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IM-
PLIED, ORANY OTHER FAILURE OF THIS PRODUCT. Some states do not allow the exclusion of incidental or consequential
damages, so this limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF
ANY IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICU-
LAR PURPOSE, IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow
limitations on how long an implied warranty lasts, so the above limitation may not apply to your.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
Home and Building Control
Honeywell International, Inc.
1985 Douglas Drive North
Golden Valley, MN 55422
Home and Building Control
Honeywell Limited-Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Download from Www.Somanuals.com. All Manuals Search And Download.
|