Honeywell CT3600/CT3697
PROGRAMMABLE THERMOSTAT
OWNER’S GUIDE
Seven Day Programmable Heat and/or Cool
Low Voltage (20 to 30 Vac) Thermostat and Wallplate
Model CT3600/CT3697
Para obtener un documento con las instrucciones en español, por favor visite
Pour obtenir des notices techniques en français, veuillez consulter notre site web
Contents
Step 1. Prepare for Installation ...................................................................................................................................
Step 2. Remove Old Thermostat ................................................................................................................................
Step 3. Mount Thermostat Wallplate ..........................................................................................................................
Step 4. Wire Wallplate Terminals ................................................................................................................................
Step 5. Install the Batteries .........................................................................................................................................
5
6
7
8
9
Step 6. Set Fan Operation Switch .............................................................................................................................. 10
Step 7. Mount the Thermostat .................................................................................................................................... 11
Step 8. Customize Your Thermostat ........................................................................................................................... 11
Step 9. Set the Clock .................................................................................................................................................. 13
Step 10. Programming ................................................................................................................................................ 14
Step 11. Operating Your Thermostat .......................................................................................................................... 17
Step 12. Set the Fan and System Switches ............................................................................................................... 19
If You Have a Problem ................................................................................................................................................ 20
Smart Response™ Technology .................................................................................................................................. 21
Wiring Diagrams ......................................................................................................................................................... 22
® U.S. Registered Trademark
Copyright © 2002 Honeywell •
•All Rights Reserved
Download from Www.Somanuals.com. All Manuals Search And Download.
69-1642
TIME /TIME
SETS TIME
FORWARD OR BACK
DIGITAL DISPLAY
RAISES
TEMPERATURE SETTING
SET CURRENT
DAY/TIME
SETS CURRENT
TIME AND DAY
LOWERS
TEMPERATURE SETTING
DISPLAYS
CURRENT HEAT/COOL
TEMPERATURE SETTING
RUN PROGRAM
RETURNS
THERMOSTAT
TO NORMAL
OPERATING MODE
PROGRAM PERIODS
WAKE/LEAVE/RETURN/SLEEP:
ENTERS PROGRAMMING MODE
Time
Set Program
Leave
Set Current
Day/Time
Run
Program
Wake
Return
Sleep
Heat
Off
Cool
SYSTEM SWITCH
HOLD TEMP
SETS A HOLD
TEMPERATURE
SETTING AND
ACTIVATES
Heat/Cool
Settings
Hold Temp
Day
System
SELECTS HEAT/OFF/COOL
On
Auto
Daylight
Time
Copy
Usage
Fan
FAN SWITCH
SELECTS AUTO/ON
VACATION HOLD
FEATURE
DAY
SETS DAY OF
THE WEEK
HEAT/COOL SETTING
SWITCHES BETWEEN
HEAT SETPOINTS AND
COOL SETPOINTS
COPY
COPY SETTINGS FROM
ONE DAY TO ANOTHER DAY
FOR QUICK PROGRAMMING
WHILE PROGRAMMING
DAYLIGHT TIME
SELECTS STANDARD
TIME OR DAYLIGHT
SAVINGS TIME
USAGE
M18635C
TRACKS EQUIPMENT RUNTIME
3
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
DISPLAYS EITHER CURRENT
TIME OF DAY OR PROGRAM TIMES
SHOWS THERMOSTAT IS IN
THE SET DAY/TIME MODE
SHOWS WHEN
THERMOSTAT IS IN THE
PROGRAMMING MODE
SHOWS TEMPERATURE SETTING
CHANGED FOR THIS PROGRAM PERIOD
SHOWS VACATION
HOLD DURATION
SHOWS THE TEMPERATURE
DISPLAYED IS THE CURRENT
SET TEMPERATURE
Temporary Setting
Set Program
Set Day/Time
Hold for
SHOWS CURRENT
DAY OR DAYS BEING
PROGRAMMED
AM
Em Ht
Room
Humid
Outdoor
Repl Batt
SHOWS THE TEMPERATURE
DISPLAYED IS THE CURRENT
ROOM TEMPERATURE
Aux Ht
MonTueWedThuFriSatSun Days
WakeLeaveReturnSleep
System
In Recovery Filter
DST
Auto Wait
SHOWS CURRENT
PROGRAM PERIOD
OR PERIOD BEING
PROGRAMMED
SHOWS THE BATTERIES ARE
LOW AND MUST BE
REPLACED
Heat
Off Cool
Em
DISPLAYS EITHER ROOM
OR SET TEMPERATURES
SHOWS CURRENT
SYSTEM KEY POSITION
HEAT/OFF/COOL
SHOWS THAT THERMOSTAT IS
"CALLING" FOR HEAT OR COOL
SHOWS SMART RESPONSE IS OFF.
CONVENTIONAL RECOVERY IS ON
SHOWS SYSTEM ON DAYLIGHT SAVINGS TIME
SHOWS THERMOSTAT IS PROCESSING
SHOWS SMART RESPONSE IS CHANGING
THE TEMPERATURE TO MEET THE
CURRENT PROGRAMS
INFORMATION AND WAITING TO CALL FOR HEAT OR COOL
M16421C
69-1642
4
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 1. PREPARE FOR INSTALLATION
❑ Check Table 1, the compatibility chart, to make sure the thermostat is compatible with your system. If your system
is not compatible, call Honeywell Customer Relations Center, toll-free, 1-800-468-1502.
Table 1. Compatibility Chart.
Compatibility with CT3600/
System Type
CT3697
Gas — Standing Pilot
Gas — Electronic Ignition
Gas-fired Boilers
Yes
Yes
Yesa
Yes
Gas — 750 Millivolt Heat onlyb
Oil-Fired Boilers
Yesa
Yes
Yes
Yes
No
Oil-Fired Furnace
Electric Furnace
Electric Air Conditioning
Baseboard Electric (120/240 line volt)c
Single Stage Heat Pump
Yes
No
Multistage Heat Pumps/Multistage Equipment
a Compatible with 2-wire Honeywell and Taco zone valves. Not compatible with 3-wire zone valves or 2-wire White
Rodgers no. 1361 zone valves.
b
Millivolt system must be heating only.
Not compatible with any 120/240 volt system.
c
Package Contents
•
•
Thermostat
•
•
Wallplate
Owner’s Guide
•
Screws and anchors
Wiring labels
Tools Required
•
•
Screwdriver
Drill
5
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 2. REMOVE OLD THERMOSTAT
❑ Test your heating and cooling systems to make sure they work properly. If either system does not work, contact
your local heating/air-conditioning dealer. To avoid compressor damage, do not operate the cooling system when
outdoor temperature is below 50°F (10°C).
❑ Turn off power to the system at the furnace or the fuse/circuit breaker panel.
❑ Carefully unpack your new thermostat and wallplate. Save package of screws, instructions, and receipt.
❑ Remove the cover from the old thermostat. If the cover does not snap off when pulled firmly from the bottom, check
for a screw or screws used to lock on the cover.
❑ Loosen the screw or screws holding the thermostat to the wallplate and lift the thermostat away.
❑ Disconnect the wires from the old thermostat. As you disconnect each wire, attach the enclosed labels with the old
terminal designation. If there are only two wires, they do not need to be labeled. Wrap the wires around a pencil as
shown to keep them from falling back into the wall.
Special Installations
Read this section if you are replacing:
WIRES THROUGH
WALL OPENING
•
•
•
Clock thermostat with separate wires for the clock.
Thermostat with six or more wires connected to it.
Thermostat in a heating only system with three wires.
M5136
Replacing a Clock Thermostat that has C or C1 Clock Terminals
If you are replacing a Honeywell Chronotherm®Thermostat, you may find one or two
wires going to the C or C1 clock terminals on the Chronotherm wiring wallplate. Do not allow them to touch, or you can
damage the transformer. Disconnect the wires and wrap them separately using electrical tape. Do not wrap them
together. Place the wires where they will not interfere with the operation of the new thermostat. Record the colors and
terminal designation labels of the remaining wires.
Replacing a Thermostat that has Six or More Wires
If there are six or more wires (excluding clock wires attached to terminals), you probably have a variation of a
multistage heat pump or other multistage system. This thermostat is not compatible with multistage systems, so return
the product to the place of purchase. For information about which programmable thermostats will work with your
system, call Honeywell Customer Relations Center, at 1-800-468-1502.
Replacing a Thermostat that has Three Wires
If you have three wires for a heating only system and can operate the fan using the fan ON switch this thermostat
works with your system. However, some hot water (zoned) heating systems also have three wires. Your thermostat will
work only if you install an isolating relay on these systems. For details, call your local heating and/or cooling contractor.
69-1642
6
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 3. MOUNT THERMOSTAT WALLPLATE
❑ Separate the wallplate from the thermostat by placing your thumb or fingers
between the bottom of the wallplate and the thermostat, and pulling the
wallplate up and away from the thermostat. See illustration at right.
❑ Position the wallplate on the wall. Level the wallplate for appearance if desired.
Use a pencil to mark the two mounting holes that best fit the application.
❑ Remove the wallplate from the wall. Drill two 3/16 in. holes in wall (if drywall) as
shown. For materials such as plaster or wood, drill 7/32 in. holes where marked.
Gently, tap the (provided) anchors into the drilled holes until they are flush with
the wall.
❑ Reposition the wallplate over the holes. Pull the wires through the wiring
opening. Loosely insert mounting screws into each of the holes.
❑ Level the wallplate if desired. Thermostat functions properly when not level.
❑ Tighten mounting screws.
M16427
WALL
WIRES
THROUGH WALL
WALL
ANCHORS (2)
MOUNTING
HOLES
MOUNTING
SCREWS
M15044
7
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 4. WIRE WALLPLATE TERMINALS
IMPORTANT
All wiring must comply with local codes and ordinances. If
unsure about household wiring procedures, call your local heat-
ing/air-conditioning contractor.
Refer to the labels you placed on the wires when you removed the old
thermostat (see illustration).
❑ Match the letter of your old thermostat wire with the corresponding
terminal letter on your new thermostat. Refer to Table 2.
❑ Remove the factory-installed jumper connecting terminals R and RC if
wires are connected to both of those terminals.
❑ For wiring diagrams, if needed, see pp 22-23.
❑ Loosen the terminal screws. Slip each wire beneath its matching
terminal. Wraparound and straight connections are both acceptable,
(see illustration). Tighten the terminals.
FOR WRAPAROUND
INSERTION STRIP
7/16 IN. (11 MM).
FOR STRAIGHT INSERTION
STRIP 5/16 IN. (8 MM).
M16425
M4826
❑ Plug the hole in the wall with insulation to help prevent drafts from adversely affecting thermostat operation.
69-1642
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 2. Terminal Designations on Old and New Thermostats
Terminal on Old Thermostat Connect To Description
R, RHa, 4, V
R
Power
Rc, Ra
W, W1, H
Y, Y1, M
G, F
Rc
Power for cooling
W
Y
Heat
Cooling
G
O
Fan
O
Changeover in cool. (Single stage heat pump only).
Changeover in heat. (Single stage heat pump only).
Bb
Bb
Cc, Xc, Bb
W2, H2
Y2
Do not connect.
Transformer common
Do not continue installation. Second stage heat.
Call 1-800-468-1502.
Second stage cool.
a If both RH and R terminals are present on existing thermostat, remove jumper and connect Rh to R and R to Rc.
b Do not connect both O and B when wiring to a single stage heat pump. Connect O to O. Tape off B.
c
Tape off end of the wire with electrical tape and push the taped wire back into the wiring hole in the wall.
WALLPLATE
STEP 5. INSTALL THE BATTERIES
B
IMPORTANT
Install three AA alkaline batteries. Batteries must be
installed for programming and operation of the thermostat
and the heating/cooling system.
R
RC
O
W
Y
G
❑ Install the batteries in the wallplate so the positive terminals all
point up (see illustration).
❑ If the thermostat is already mounted on the wall, remove the
thermostat by placing your thumb between the thermostat and
wallplate and pulling the thermostat up and away as shown.
INSTALL 3 AA ALKALINE BATTERIES
AS SHOWN, POSITIVE (+) TERMINALS
TOWARD TOP.
M10622
9
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
When the batteries are running low, a REPL BAT message flashes for one to
two months before the batteries run out completely. Replace the batteries as
soon as possible once the message flashes.
IMPORTANT
Although the thermostat has a low battery indicator, replace the
batteries once per year to prevent leakage and to prevent the ther-
mostat and heating/cooling system from shutting down due to lack
of battery power in the thermostat.
If you insert new batteries within 20 to 30 seconds of removing the old
batteries, the system retains the current time and day. If the display is blank,
the batteries are dead or installed incorrectly. You must reset the time and
day. Refer to Set the Clock for instructions.
M16424
As a precaution when leaving home for longer than a month, change batteries before leaving to prevent
the system from shutting down due to lack of power. Always use fresh alkaline batteries. Nonalkaline
batteries do not last as long. They also can leak, causing damage to the thermostat and the wall surface.
STEP 6. SET FAN OPERATION SWITCH
The thermostat fan operation switch, labeled FUEL SWITCH is factory
set in the F position. This is the correct setting for most systems. If your
system is an electric heat system, set the switch to E. The E setting
allows the fan to turn on immediately with the heating and cooling in a
system where the G terminal is connected.
M12676
FUEL SWITCH
69-1642
10
Download from Www.Somanuals.com. All Manuals Search And Download.
STEP 7. MOUNT THE THERMOSTAT
A. ENGAGE TABS AT TOP
OF THERMOSTAT
AND WALLPLATE.
B. PRESS LOWER
EDGE OF CASE
TO LATCH.
M12703
STEP 8. CUSTOMIZE YOUR THERMOSTAT
Your Honeywell CT3600/CT3697 Thermostat comes preset to the most commonly used settings. The settings are:
— Gas or oil forced air furnace.
— Smart Response technology on.
— Temperature °F.
— 12-hour clock format.
You can change any or all of these settings.
IMPORTANT
Always press the keys with your fingertip or a similar blunt tool. Sharp instruments like pens and pencil
points can damage the keyboard.
❑ Press and hold down
,
, and , simultaneously until the screen shows.
You now can change any of these settings.
System Type (Feature Number 4)
System type options are:
— 1 = Gravity or steam system.
OPTION
FEATURE
NUMBER
M13330
11
Download from Www.Somanuals.com. All Manuals Search And Download.
69-1642
— 3 = Hot water, high efficiency furnace (90% or better), or single stage heat pump.
— 6 = Gas or oil forced air furnace (preset).
— 9 = Electric furnace.
To change your system type:
❑ Press
until display shows your furnace or boiler type.
Run
Program
❑ Press Time
to move to next feature or
to return to main display.
Smart Response™ Technology (Feature Number 13)
Smart Response technology options are:
— 0 = Smart Response technology on (preset).
— 1 = Smart Response technology off.
M13343
To turn Smart Response technology on or off:
❑ Press
once.
Run
Program
❑ Press Time
to move to next feature or
to return to main display.
NOTE: See Smart Response technology (page 21) for information about this feature.
Temperature Format (Feature Number 14)
Temperature format options are:
— 0 = °F (preset).
— 1 = °C.
M13344
To change temperature format:
❑ Press
once.
Run
Program
❑ Press Time
to move to next feature or
to return to main display.
Time Format (Feature Number 16)
Time format options are:
— 0 = 12-hour clock (preset).
— 1 = 24-hour clock.
M13345
69-1642
12
Download from Www.Somanuals.com. All Manuals Search And Download.
To change time format:
❑ Press
❑ Press
once.
Run
Program
to return to main display.
Factory Set Function (Feature Number 37)
Do not change this setting.
M13346
STEP 9. SET THE CLOCK
Set Current Day and Time
NOTE: On initial power-up, the screen flashes 1:00 pm until you press a key.
Set Current
Day/Time
❑ Press
❑ Press
.
Day
until screen shows current day.
or until screen shows current time. (Tapping the
Set Current
Day/Time
❑ Press Time
will advance the time in one
hour increments).
Daylight
Time
❑ Press
❑ Press
until “DST” displays if daylight savings time is in effect.
Run
Program
.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
69-1642
STEP 10. PROGRAMMING
The keyboard is located behind the thermostat cover. The three most frequently used keys are near the display.
Pressing
displays the current temperature settings. Pressing the
and
keys change the temperature. The
thermostat displays day, time, program period, temperature and system settings.
There is an individual key for each of the four program periods:
Wake
—The program period when you want the house at a comfortable temperature when you get up and while you
get ready for work or school. (This is a higher temperature during the heating season and a lower
temperature during the cooling season).
—The program period you can set for an energy-saving temperature while you are away at work or school.
(This is a lower temperature during the heating season and a higher temperature during the cooling
season).
—The program period when you want the house at a comfortable temperature for activities before bedtime.
(This is a higher temperature during the heating season and a lower temperature during the cooling
season).
—The program period you can set for an energy-saving temperature while you are sleeping. (This is a lower
temperature during the heating season and a higher temperature during the cooling season.)
Leave
Return
Sleep
69-1642
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Table 3 can be helpful when planning your schedule of time and temperature settings. The thermostat default settings
are shown in parentheses ( ).
Table 3. Personal Programming Table.
Monday
(Mon)
Tuesday Wednesday Thursday Friday
(Tue) (Wed) (Thu) (Fri)
Saturday Sunday
Period
Default Setting
Time (6:00AM)
(Sat)
(Sun)
Wake
Heata (70°F/21°C)
Coolb (78°F/25.5°C)
Time (8:00AM)
Leave
Return
Sleep
Heata (62°F/16.5°C)
Coolb (85°F/29.5°C)
Time (6:00PM)
Heata (70°F/21°C)
Coolb (78°F/25.5°C)
Time (10:00PM)
Heata (62°F/16.5°C)
Coolb (82°F/28°C)
a Your heating setpoints cannot be higher than 90°F (32°C) or lower than 40°F (4.5°C).
b Your cooling setpoints cannot be higher than 99°F (37°C) or lower than 45°F (7°C).
Program the First Day
Start by programming the wake time and temperature for one day.
Wake
❑ Press and release
.
Day
❑ Press
until the desired day displays. (Mon, Tue, Wed, Thu, Fri, Sat, Sun)
❑ Press time
or
until the desired time shows in the display.
15
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
NOTE: Program times are in 15 minute intervals. For example, 8:00, 8:15, 8:30.
❑ Press or until the desired wake temperature displays.
The setpoint temperature range is 40°F to 90°F (4.5°C to 32°C) for heating and 45°F to 99°F (7°C to 37°C) for cooling.
Heat/Cool
Settings
❑ Press
to switch between setpoints.
NOTE: Program times are the same for heating and cooling.
❑ Press
or
until the display shows the desired temperature setpoint.
Leave
Sleep
Return
❑ Press
,
or
and repeat these steps for each program period. The First Day is now
programmed.
❑ Repeat each step in Program the First Day for the rest of the week.
NOTE: After the first day is programmed, you can copy that day to any other day using procedure in Copy a Day.
Run
Program
❑ Press
when the entire week is programmed.
Copy a Day
Your thermostat can copy program settings from one day to another.
Wake
Leave
Return
Sleep
❑ Press
❑ Press
❑ Press
,
,
or
until the display shows the day you want to copy.
. The display shows.
to enter programming mode.
Day
Copy
Mon
M13327
69-1642
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Day
❑ Press
❑ Press
until the display shows the day you want to copy to.
Mon
Wed
M13328
M13329
Copy
to accept the change.
❑ Repeat these steps for each day you want to copy.
NOTE: donE appears for two seconds and then the normal program display appears.
Clear a Program Period
NOTE: Wake cannot be cleared.
Leave
Sleep
Return
❑ Press
❑ Press
,
, or
for the program period you want to clear.
Day
until the desired day displays.
Leave
Sleep
Return
❑ Press and hold the
,
, or
for approximately 3 seconds until the time and temperature clear.
❑ Repeat the above steps for each period to be cleared.
Run
Program
❑ Press
.
STEP 11. OPERATING YOUR THERMOSTAT
Change Temperature Setting Until the Next Program Period (Temporary Change)
❑ Press
or
until the screen shows the desired temperature setting.
NOTE: The temporary temperature setting is displayed for about 3 seconds and then the room temperature is dis-
played. Temporary appears in the display. The setting cancels when the next program period starts or when
Run
Program
you press
.
17
Download from Www.Somanuals.com. All Manuals Search And Download.
69-1642
Change Temperature Setting Indefinitely (Hold)
❑ Move the System switch to the desired position (Heat or Cool).
Hold Temp
❑ Press
then
or
to change your setting if desired. (The display changes from showing the setpoint
temperature to room temperature after approximately three seconds).
Run
Program
❑ To cancel “Hold” press
.
Change the Temperature Setting Until a Designated Day and Period (Vacation Hold)
Hold Temp
❑ Press
❑ Press
twice.
until the display shows the desired temperature setpoint.
until the desired number of days that you will be away (1 through 255) is displayed.
or
❑ Press Time
Leave
Sleep
Return
Wake
❑ Press
,
,
or
to select the program period when you want the program to restart.
Run
Program
NOTE: If the Vacation Hold needs to be cancelled before the designated time, press
program.
to return to the
Daylight Savings Time Key
This feature allows you to switch between standard time and daylight savings time.
Daylight
Time
❑ Press
during fall to set the time back one hour.
during the spring to set time forward one hour. DST is displayed when operating on daylight savings
Daylight
Time
❑ Press
time.
NOTE: Pressing the Daylight Time key more than once in a five minute period scrolls you through various time
options. For example, one hour earlier or later, with or without DST. Pressing Daylight Time six times in a
five minute period returns you to your original setting.
69-1642
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Usage Key
Usage
❑ Press
once to display the hours and minutes that the heating or cooling system has been operating for the
current day.
Usage
❑ Press
a second time to display the system operating time for the previous day (midnight to midnight).
a third time to display the system operating time since the last time the usage function was cleared.
Usage
❑ Press
Usage
NOTE: Press
for three seconds to clear the usage function.
STEP 12. SET THE FAN AND SYSTEM SWITCHES
First set the fan switch. Fan On: The fan runs continuously. Use for improved air
circulation or for more efficient central air cleaning. (In a
heat-only system, fan runs continuously only if fan relay is
connected to the G thermostat terminal).
On
Fan
Auto
Fan Auto: Normal setting for most homes. The equipment
controls the fan operation.
On
Fan
Auto
Cool
Cool
Cool
Then set the system
switch.
Heat: The thermostat controls your heating system.
Off: Both the heating and air conditioning systems are off.
Cool: The thermostat controls your air conditioning system.
Heat
System
Off
Heat
System
Off
Off
Heat
System
19
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
IF YOU HAVE A PROBLEM
Table 4. Solution Guide.
If...
Then…
Display does not appear.
•
•
Make sure the batteries are installed correctly.
Make sure the thermostat is mounted and latched on the wallplate.
Mount and latch the thermostat on the wallplate if it is not.
Temperature settings will not change
(example; cannot set the heating higher
or the cooling lower).
•
Make sure the temperature setpoints are:
40 to 90°F (4.5 to 32°C) for heating.
45 to 99°F (7 to 37°C) for cooling.
Heating does not come on.
•
•
•
Make sure the heating setpoint is above the room temperature.
Make sure the circuit breaker is not tripped, and reset it if necessary.
Make sure the power switch at the equipment is in the On position, and
set it to On if it is in the Off position.
•
•
Wait five minutes for the system to respond.
Set the system switch to Heat.
Cooling does not come on.
•
•
•
Make sure the cooling setpoint is below the room temperature.
Make sure the circuit breaker is not tripped, and reset it if necessary.
Make sure the system switch at the air conditioner is in the On position,
and set it to On if it is in the Off position.
•
•
Wait five minutes for the system to respond.
Set the system switch to Cool.
Wait five minutes after seeing the flame or snowflake and check the
registers again. If no there is no hot or cool air coming from the registers,
refer to Heating does not come on or Cooling does not come on. If all of this
has been checked, contact your local heating and cooling contractor.
System on indicator( = heat,
cool) is lit, but no warm or cool air is
coming from the registers.
=
Display flashes during programming.
The temperature setting limit has been reached. The heating setting range
is 40°F to 90°F (4.5°C to 32°C). The cooling setting range is 45°F to 99°F
(7°C to 37°C).
Temperature change occurs at the
wrong times.
1. Check the program times for the period in question.
2. Make sure the AM and PM settings are correct.
3. Make sure the current time and day settings are correct.
4. Reprogram any incorrect settings.
NOTE: If your thermostat is set for Smart Response™ technology, the
start times occur before your programmed comfort periods.
69-1642
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Customer Assistance
Please read and follow the provided instructions for this thermostat. For additional information, go to
Before calling, please have the following information available:
•
•
•
•
Thermostat model number. (Located on back of thermostat).
Thermostat date code. (Located below model number).
Type of heating/cooling system (for example, hot water, warm air, oil, or gas).
Location and number of wires connected to the thermostat.
SMART RESPONSE™ TECHNOLOGY
Your CT3600/CT3697 is actually a small computer. The Smart Response technology calculates the correct time of day
to turn on your heating or cooling system. Smart Response technology considers the following information.
•
•
•
Air temperature.
Wall temperature.
The time of day when you want the comfort temperature established.
System Operating
in Comfort Mode
When the thermostat activates Smart
Response technology, the thermostat
displays In Recovery, changes the
setpoint, and turns on the system.
AM
Room
68°F
66°F
Mon
Wake
System
Heat
Recovery
Continues
AM
Room
•
•
•
Your CT3600/CT3697 Thermostat
learns from experience. Each day it
checks how closely it hit the recovery
target and then adjusts the next day’s
recovery start time accordingly.
It takes a few days after installation for
the thermostat to adjust to the local
weather, your lifestyle, the construction
of your home, and your heating/cooling
system.
Mon
Heat
Sleep In Recovery
System
Heat
Recovery
Begins
1
AM
Room
64°F
62°F
Mon
Heat
Sleep In Recovery
System
Heat
System Operating in
Energy Savings Mode
AM
Room
Mon
Sleep
System
Heat
5:00
5:30
6:00
6:30
ENERGY
SAVINGS
PERIOD
COMFORT
PERIOD
RECOVERY FROM ENERGY SAVINGS
TIME
THERMOSTAT USES THE SAME SCHEME TO RETURN TO LOWER COMFORT TEMPERATURE DURING
THE COOLING SEASON.
You can turn off Smart Response
technology by selecting Conventional
Recovery. See Step 8. Customize Your
Thermostat.
M18591
1
IF In Recovery IS DISPLAYED, PRESS
TO SEE THE COMFORT SETPOINT.
21
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
WIRING DIAGRAMS
4-WIRE HEAT/COOL
(JUMPER INTACT)
2-WIRE HEAT-ONLY
(JUMPER INTACT)
THERMOSTAT
THERMOSTAT
B
B
RC
O
W
Y
RC
O
W
Y
R
G
R
G
HEATING
COOLING
CONTACTOR
COIL
FAN
RELAY
HEATING
RELAY OR
VALVE COIL
RELAY OR
1
VALVE COIL
1
1
POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
1
POWER SUPPLY.
PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
M10617
M10616
4-WIRE SINGLE-STAGE HEAT PUMP
(JUMPER INTACT)
3-WIRE HEAT ONLY WITH FAN
(JUMPER INTACT)
THERMOSTAT
B
THERMOSTAT
B
RC
O
W
Y
R
G
RC
O
W
Y
3
R
G
2
HEAT
CHANGEOVER
VALVE
COMPRESSOR
CONTACTOR
2
HEATING
COOL
CHANGEOVER
VALVE
FAN
RELAY
1
FAN
RELAY OR
1
VALVE COIL
RELAY
1
POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION AS REQUIRED.
POWER SUPPLY. PROVIDE DISCONNECT MEANS
AND OVERLOAD PROTECTION AS REQUIRED.
1
2
3
M10618
USE EITHER O OR B FOR HEAT PUMP CHANGEOVER.
USING A JUMPER WIRE (NOT SUPPLIED) CONNECT W TO Y.
M12739
69-1642
22
Download from Www.Somanuals.com. All Manuals Search And Download.
5-WIRE HEAT/COOL
(JUMPER REMOVED)
5-WIRE HEAT/COOL WITH DAMPER
(JUMPER INTACT)
THERMOSTAT
B
THERMOSTAT
B
RC
O
W
Y
RC
O
W
Y
R
G
R
G
HEAT
DAMPER
HEATING
RELAY OR
VALVE COIL
FAN
HEAT
RELAY
COMPRESSOR
CONTACTOR
COOLING
CONTACTOR
COIL
RELAY
1
1
COOL
DAMPER
FAN
RELAY
1
1
POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND OVERLOAD
M10619
1
POWER SUPPLY. PROVIDE
DISCONNECT MEANS AND
OVERLOAD PROTECTION
AS REQUIRED.
PROTECTION AS REQUIRED.
M18738
Notice:
This thermostat is a Class B digital apparatus that complies with Canadian Radio Interference Regulations,
CRC c. 1374.
23
69-1642
Download from Www.Somanuals.com. All Manuals Search And Download.
Limited One-Year Warranty
Honeywell warrants this product, excluding battery, to be free from defects in the workmanship or materials, under normal use and
service, for a period of one (1) year from the date of purchase by the consumer. If, at any time during the warranty period, the product is
defective or malfunctions, Honeywell shall repair or replace it (at Honeywells option) within a reasonable period of time.
If the product is defective,
(i)
return it, with a bill of sale or other dated proof of purchase, to the retailer from which you purchased it, or
(ii) package it carefully, along with proof of purchase (including date of purchase) and a short description of the malfunction, and mail it, postage
prepaid, to the following address:
Honeywell USA
Honeywell Canada:
Dock 4 — MN10-3860
1885 Douglas Drive North
Golden Valley, MN 55422-3992
Honeywell Limited/Honeywell Limitée
35 Dynamic Drive
Scarborough, Ontario M1V 4Z9
This warranty does not cover removal or reinstallation costs. This warranty shall not apply if it is shown by Honeywell that the defect or
malfunction was caused by damage which occurred while the product was in the possession of a consumer.
Honeywells sole responsibility shall be to repair or replace the product within the terms stated above. HONEYWELL SHALL NOT BE
LIABLE FOR ANY LOSS OR DAMAGE OF ANY KIND, INCLUDING ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES
RESULTING, DIRECTLY OR INDIRECTLY FROM ANY BREACH OF ANY WARRANTY, EXPRESS OR IMPLIED, OR ANY OTHER
FAILURE OF THIS PRODUCT. Some states do not allow the exclusion or limitation of incidental or consequential damages, so this
limitation may not apply to you.
THIS WARRANTY IS THE ONLY EXPRESS WARRANTY HONEYWELL MAKES ON THIS PRODUCT. THE DURATION OF ANY
IMPLIED WARRANTIES, INCLUDING THE WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE,
IS HEREBY LIMITED TO THE ONE YEAR DURATION OF THIS WARRANTY. Some states do not allow limitations on how long an
implied warranty lasts, so the above limitation may not apply to you.
This warranty gives you specific legal rights, and you may have other rights which vary from state to state.
If you have any questions concerning this warranty, please write Honeywell Customer Relations, 1885 Douglas Dr. N., Golden Valley,
MN 55422-3992. In Canada, write Retail Products ON30 Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough,
Ontario M1V 4Z9.
Automation and Control Solutions
Honeywell
Honeywell Limited-Honeywell Limitée
1985 Douglas Drive North
Golden Valley, MN 55422
35 Dynamic Drive
Scarborough, Ontario
M1V 4Z9
Printed in U.S.A. on recycled
paper containing at least 10%
post-consumer paper fibers.
69-1642 G.H. 7-02
Download from Www.Somanuals.com. All Manuals Search And Download.
|