ST 3000 Smart Transmitter  
Series 900 Remote Diaphragm Seals Models  
Specification and  
Model Selection  
Guide  
STR93D  
STR94G  
0 to 100 psid  
0 to 500 psig  
0 to 7 bar  
0 to 35 bar  
Introduction  
In 1983, Honeywell introduced the first  
Smart Pressure Transmitterthe ST  
3000®. In 1989, Honeywell launched  
the first all digital, bi-directional protocol  
for smart field devices. Today, its  
ST 3000 Series 900 Remote Seal  
Transmitters continue to bring proven  
“smart” technology to a wide spectrum  
of pressure measurement applications.  
For applications in which the  
transmitter must be mounted remotely  
from the process, Honeywell offers the  
remote seal line of gauge, absolute and  
differential pressure transmitters.  
Typical applications include level  
measurement in pressurized vessels in  
the chemical and hydrocarbon  
processing industries. A second  
application is flow measurement for  
slurries and high viscosity fluids in the  
chemical industry. Honeywell remote  
seal transmitters are available with  
secondary fill fluids for corrosive or high  
temperature process fluids  
Figure 1—Series 900 Remote Seal Pressure Transmitters feature proven  
piezoresistive sensors and advanced seal technology with standard weld  
connections.  
All ST 3000 transmitters can provide a  
4-20 mA output, Honeywell Digitally  
Enhanced (DE) output, HART* output,  
or FOUNDATIONFieldbus output.  
When digitally integrated with  
Honeywell’s Process Knowledge  
System™, EXPERION PKS™,  
ST 3000 instruments provide a more  
accurate process variable as well as  
advanced diagnostics.  
The devices provide comprehensive self-diagnostics to help users  
maintain high uptime, meet regulatory requirements, and attain high  
quality standards. S900 transmitters allow smart performance at  
analog prices. Accurate, reliable and stable, Series 900 transmitters  
offer greater turndown ratio than conventional transmitters.  
"Honeywell transmitters operating in the digital mode using  
Honeywell's Digitally Enhanced (DE) protocol make diagnostics  
available right at the control system's human interface. Equally  
important, transmitter status information is continuously displayed to  
alert the operator immediately of a fault condition. Because the  
process variable (PV) status transmission precedes the PV value, we  
are guaranteed that a bad PV is not used in a control algorithm. In  
addition, bi-directional communication provides for remote transmitter  
configuration directly from the human interface, enabling management  
of the complete loop.”  
Honeywell’s cost-effective ST 3000  
S900 transmitters lead the industry in  
reliability and stability:  
Stability = ±0.01% per year  
Reliability = 470 years MTBF  
Maureen Atchison, DuPont  
Site Electrical & Instrumentation Leader  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 3  
Description of Diaphragm Seals  
Figure 6 - Seals with Threaded Process  
Connections can be used with differential, gauge and  
absolute pressure transmitters and are available with  
½”, ¾” and 1” NPT Female process connections.  
Figure 6  
Figure 7 - Sanitary Seals can be used with  
differential, gauge and absolute pressure transmitters  
and are available with 3” and 4” Tri-Clover-Tri-Clamp  
process connections.  
Figure 7  
Figure 8  
Figure 9  
Figure 10  
Figure 8 - Saddle Seals can be used with differential,  
gauge and absolute pressure transmitters and are  
available with 3” and 4” (6 bolt or 8 bolt designs)  
process connections.  
Figure 9 - Calibration Rings are available with Flush  
Flange Seals and Pancake Seals. Flushing ports (1/4”  
or ½”) are available with calibration rings.  
Figure 10 - Stainless Steel Armor and PVC Coated  
Stainless Steel Armor Capillaries are available with  
Honeywell Remote Seal Solutions.  
Figure 11 - 2” Stainless Steel Nipples are available  
for Close-Coupled remote seal solutions.  
Figure 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 4  
Figure 12 - Welded Meter Body for All-Welded  
Remote Seal Solution. The welded ST 3000 meter  
body is an important part of an All-Welded Remote  
Seal Solution, which is commonly used in Vacuum  
applications.  
Figure 12  
Description  
Features  
Choice of linear or square  
root output conformity is a  
simple configuration selection.  
The ST 3000 transmitter can replace any 4 to 20 mA output transmitter in  
use today and operates over a standard two-wire system.  
The measuring means is a piezoresistive sensor, which actually contains  
three sensors in one. It contains a differential pressure sensor, a  
temperature sensor, and a static pressure sensor.  
Direct digital integration with  
Experion PKS and other  
control systems provides local  
measurement accuracy to the  
system level without adding  
typical A/D and D/A converter  
inaccuracies.  
Microprocessor-based electronics provide higher span-turndown ratio,  
improved temperature and pressure compensation, and improved  
accuracy.  
Unique piezoresistive sensor  
automatically compensates  
input for temperature and  
static pressure.Added “smart”  
features include configuring  
lower and upper range  
values, simulating accurate  
analog output, and selecting  
preprogrammed engineering  
units for display.  
The transmitter’s meter body and electronics housing resist shock,  
vibration, corrosion, and moisture. The electronics housing contains a  
compartment for the single-board electronics, which is isolated from an  
integral junction box. The single-board electronics is replaceable and  
interchangeable with any other ST 3000 Series 100 or Series 900 model  
transmitter.  
Like other Honeywell transmitters, the ST 3000 features two-way  
communication and configuration capability between the operator and the  
transmitter through several Honeywell field-rated portable configuration  
devices, including the Smart Field Communicator (SFC) and the Multiple  
Communication Configurator (MC ToolKit). While both are made for in-  
field use, the MC Toolkit also can be ordered for use in intrinsically safe  
environments.  
Smart transmitter capabilities  
with local or remote  
interfacing means significant  
manpower efficiency  
improvements in  
commissioning, start-up, and  
ongoing maintenance  
functions.  
The SCT 3000 Smartline® Configuration Toolkit provides an easy way to  
configure instruments using a personal computer. The toolkit enables  
configuration of devices before shipping or installation. The SCT 3000 can  
operate in the offline mode to configure an unlimited number of devices.  
The database can then be loaded down-line during commissioning.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 5  
Specifications  
Operating Conditions – All Models  
Parameter  
Reference  
Condition  
(at zero  
Rated Condition  
Operative Limits  
Transportation  
and Storage  
static)  
°C  
°F  
°C  
°F  
°C  
°F  
°C  
°F  
Ambient Temperature  
25 ±1 77 ±2  
25 ±1 77 ±2  
-25 to 70  
-13 to 158  
-40 to 85  
-40 to 185 -55 to 125 -67 to 257  
-55 to 125 -67 to 257  
See Figure 13  
Process Interface  
Temperature  
Humidity  
%RH  
10 to 55  
0 to 100  
0 to 100  
0 to 100  
Maximum Allowable  
Working Pressure (MAWP)  
MAWP is minimum of Body Rating or Seal Rating (See Model Selection Guide for Seal  
MAWP)  
Body  
MAWP  
STR93D  
STR94G  
750 psig (52 bar)  
500 psig (35 bar)  
Vacuum Region, Minimum  
Pressure - mmHg absolute  
atmospheric  
atmospheric  
See Figure 13  
inH O absolute  
2
Supply Voltage, Current,  
and Load Resistance  
Voltage Range: 10.8 to 42.4 Vdc at terminals  
Current Range: 3.0 to 21.8 mA  
Load Resistance: 0 to 1440 ohms (as shown in Figure 14)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 6  
Maximum Pressure Limited  
by Flange Rating of Seal  
10000  
9000  
8000  
7000  
6000  
193  
psig  
Silicone DC704  
30 to 450°F  
5000  
4000  
3000  
2000  
Silicone DC200  
-40 to 350°F  
1000  
900  
800  
700  
600  
500  
1Atm  
0
CTFE  
psig  
5 to 300°F  
400  
300  
200  
-9  
psig  
100  
90  
80  
70  
60  
50  
40  
30  
Special High Vacuum  
Construction required.  
Consult STC.  
Pressure20  
(mmHgA)  
-14  
10  
psig  
450  
-40  
-100  
175  
350  
5
25 30  
100  
500  
0
200  
300  
400  
Process Temperature (Degrees F)  
Maximum Pressure Limited  
by Flange Rating of Seal  
10000  
9000  
193  
psig  
8000  
7000  
6000  
Syltherm 800  
-40 to 600°F  
90  
psig  
5000  
4000  
NEOBEE M-20  
30 to 400°F  
3000  
2000  
1000  
900  
800  
700  
600  
500  
1Atm  
0
psig  
400  
300  
200  
-9  
psig  
100  
90  
80  
70  
60  
50  
40  
30  
Pressure20  
(mmHgA)  
-14  
10  
psig  
550  
-40  
-100  
175  
450  
5
25 30  
100  
600  
20335  
0
200  
400  
500  
Process Temperature (Degrees F)  
Figure 13—ST 3000 Remote Seals operable limits for pressure versus temperature  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 7  
1440  
1200  
Note: A minimum of 250 ohms  
of loop resistance is necessary  
to support communications.  
Loop resistance equals barrier  
resistance plus wire resistance  
plus receiver resistance.  
Loop  
Resistance  
(ohms)  
800  
650  
450  
250  
= Operating Area  
0
10.8  
16.28 20.63 25 28.3 37.0  
42.4  
Operating Voltage (Vdc)  
Figure 14—Supply voltage and loop resistance chart  
Performance Under Rated Conditions * - Model STR93D (0 to 100 psi/7 bar)  
Parameter  
Description  
Upper Range Limit  
psi  
bar  
100 (Transmitter URL or maximum seal pressure rating, whichever is lower.)  
7
Minimum Span  
Turndown Ratio  
psi  
bar  
0.9  
0.063  
110 to 1  
Zero Elevation and Suppression No limit except minimum span within ±100% URL.  
Accuracy (Reference – Includes  
combined effects of linearity,  
hysteresis, and repeatability)  
In Analog Mode: ±0.20% of calibrated span or upper range value (URV), whichever is  
greater, terminal based.  
For URV below reference point (50 inH O), accuracy equals:  
2
Accuracy includes residual error  
after averaging successive  
readings.  
50 inH O  
2
125 mbar  
(span mbar)  
±0.10 + 0.10  
or ±0.10 + 0.10  
in % of span  
span inH O  
2
In Digital Mode: ±0.175% of calibrated span or upper range value (URV), whichever  
is greater, terminal based.  
For FOUNDATION Fieldbus use  
Digital Mode specifications. For  
HART use Analog Mode  
specifications.  
For URV below reference point (50 inH O), accuracy equals:  
2
50 inH O  
2
125 mbar  
(span mbar)  
±0.075 + 0.10  
or ±0.075 + 0.10  
in % of span  
span inH O  
2
Combined Zero and Span  
Temperature Effect per 28°C  
(50°F) **  
In Analog Mode: ±1.5% of span.  
For URV below reference point (200 inH O), effect equals:  
2
200 in H2O  
500 mbar  
In % span  
or ±0.30 + 1.2  
±0.30 + 1.2  
span in H2O  
span mbar  
In Digital Mode: ±1.475% of span.  
For URV below reference point (200 inH O), effect equals:  
2
200 in H2O  
500 mbar  
In % span  
or ±0.275 + 1.2  
±0.275 + 1.2  
span in H2O  
span mbar  
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and  
316L Stainless Steel barrier diaphragm.  
** Specification applies to transmitters with 2 seals only. Apply 1.5 times factor to temperature effect for capillary lengths greater than 10 feet  
or for 2-inch sanitary seals.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 8  
Performance Under Rated Conditions * - Models STR94G (0 to 500 psi/35 bar)  
Parameter  
Description  
Upper Range Limit  
psi  
bar  
500  
35  
Minimum Span  
Turndown Ratio  
psi  
bar  
20  
1.4  
25 to 1  
Zero Elevation and Suppression No limit except minimum span from absolute 0 (zero) to +100% URL.  
Accuracy (Reference – Includes  
combined effects of linearity,  
hysteresis, and repeatability)  
In Analog Mode: ±0.10% of calibrated span or upper range value (URV), whichever is  
greater, terminal based.  
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever  
Accuracy includes residual error is greater, terminal based.  
after averaging successive  
readings.  
For FOUNDATION Fieldbus use  
Digital Mode specifications. For  
HART use Analog Mode  
specifications.  
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and  
316L Stainless Steel barrier diaphragm.  
Transmitter Minimum Span and Maximum Capillary Length  
Minimum recommended span for STR93D DP Transmitter with two Remote Seals  
Diaphragm  
Capillary  
20'  
Capillary Length  
Size  
2.0  
2.4  
2.9  
3.5  
4.1  
5'  
10'  
15'  
25'  
-
350 iwc  
150 iwc  
32 iwc  
25 iwc  
30'  
-
400 iwc  
175 iwc  
36 iwc  
27 iwc  
35'  
-
450 iwc  
200 iwc  
40 iwc  
30 iwc  
maximum  
15 psig  
150 iwc  
50 iwc  
25 iwc  
25 iwc  
20 psig  
200 iwc  
75 iwc  
25 iwc  
25 iwc  
25 psig  
250 iwc  
100 iwc  
25 iwc  
25 iwc  
-
15'  
35'  
35'  
35'  
35'  
300 iwc  
125 iwc  
28 iwc  
25 iwc  
Minimum recommended span for STR94G or STR93D DP Transmitter with one Remote Seal  
Diaphragm Direct  
Capillary  
Capillary Length  
Size  
2.0  
2.4  
2.9  
3.5  
4.1  
Mount  
25 psi  
10 psi  
8 psi  
2 psi  
0.9 psi  
5'  
10'  
15'  
20'  
-
30 psi  
12 psi  
5 psi  
3 psi  
30'  
-
40 psi  
14 psi  
7 psi  
4 psi  
35'  
-
50 psi  
15 psi  
8 psi  
5 psi  
maximum  
30 psi  
15 psi  
9 psi  
2 psi  
0.9 psi  
40 psi  
20 psi  
10 psi  
3 psi  
50 psi  
25 psi  
11 psi  
4 psi  
15'  
35'  
35'  
35'  
35'  
1 psi  
2 psi  
Minimum span is the higher of the value from the table above or the value defined under Performance Conditions for the range transmitter  
Figure 15— Maximum capillary length and diaphragm size chart.  
Performance Under Rated Conditions - General for all Models  
Parameter  
Description  
Output (two-wire)  
Analog 4 to 20 mA or DE digital communications mode. Options available for  
FOUNDATION Fieldbus and HART protocols.  
Supply Voltage Effect  
Damping Time Constant  
CE Conformity (Europe)  
0.005% of span per volt.  
Adjustable from 0 to 32 seconds digital damping.  
89/336/EEC, Electromagnetic Compatibility (EMC) Directive.  
NAMUR NE 43 Compliance  
Option  
Transmitter failure information is generated when the measuring information is invalid or  
no longer present. Failure information is transmitted as a current signal but outside the  
normal 4-20 mA measurement signal level. Transmitter failure values are:  
3.6 mA and 21.0 mA. The normal signal range is 3.8 mA and 20.5 mA.  
SIL certified to IEC 61508 for non-redundant use in SIL 2 related Safety Systems  
(single use) and for redundant (multiple) use in SIL 3 Safety Systems through  
TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 1998;  
IEC 61508-2: 2000; IEC61508-3: 1998.  
SIL 2/3 Compliance  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 9  
Physical and Approval Bodies  
Parameter  
Description  
Process Interface  
See Model Selection Guide for Material Options for desired Seal Type.  
316L Stainless Steel, Monel, Hastelloy C, Tantalum  
Klinger C-4401 (non-asbestos)  
Seal Barrier Diaphragm  
Seal Gasket Materials  
Grafoil  
Teflon  
Gylon 3510  
Mounting Bracket  
Carbon Steel (zinc-plated) or Stainless Steel angle bracket or Carbon Steel flat  
bracket available.  
Fill Fluid (Meter Body)  
Silicone (DC 200)  
S.G. @ 25°C (77°F) = 0.94  
S.G. @ 25°C (77°F) = 1.89  
CTFE (Chlorotrifluoroethylene)  
Fill Fluid (Secondary)*  
Silicone (DC 200)  
S.G. @ 25°C (77°F) = 0.94  
S.G. @ 25°C (77°F) = 1.89  
CTFE (Chlorotrifluoroethylene)  
Silicone (DC 704)  
Syltherm 800  
S.G. @ 25°C (77°F) = 1.07  
S.G. @ 25°C (77°F) = 0.90  
NEOBEE M-20  
S.G. @ 25°C (77°F) = 0.93  
Electronics Housing  
Epoxy-Polyester hybrid paint. Low-copper aluminum alloy. Meets NEMA 4X  
(watertight) and NEMA 7 (explosion proof)  
Capillary Tubing**  
Armored Stainless Steel or PVC Coated Armored Stainless Steel. Length: 5, 10,  
15, 20, 25 and 35 feet (1.5, 3, 4.6, 6.1, 7.5 and 10.7m). A 2” (51 millimeter) S.S.  
close-coupled nipple is also available. See Model Selection Guide.  
Wiring  
Accepts up to 16 AWG (1.5 mm diameter)  
See Figure 16.  
Mounting  
Dimensions  
See Figures 19 and 20 for transmitter dimensions. See Model Selection Guide for  
Seal dimensions  
Net Weight  
Transmitter: 4.1 Kg (9 lbs). Total weight is dependent on seal type and capillary  
length.  
Approval Bodies  
Explosion Proof: Approved as Explosion Proof for Class I, Division 1, Groups A,  
B, C, D locations,  
Dust Ignition Proof: Approved as Dust Ignition Proof for Class II, III, Division 1,  
Groups E, F, G locations,  
Factory Mutual  
Intrincically Safe: Approved as Intrinsically Safe for for Class I, II, III, Division 1,  
Groups A, B, C, D, E, F, G locations.  
Nonincendive: Approved as Nonincendive for Class I, Division 2, Groups A, B, C,  
D locations.  
Explosion Proof: Approved as Explosion Proof for Class I, Division 1, Groups B,  
C, D locations,  
Dust Ignition Proof: Approved as Dust Ignition Proof for Class II, III, Division 1,  
Groups E, F, G locations,  
CSA  
Intrincically Safe: Approved as Intrinsically Safe for Class I, II, III, Division 1,  
Groups A, B, C, D, E, F, G locations.  
Canadian Registration  
Number (CRN)  
All ST 3000 model designs, except SATG19L, STG99L, STG170 and STG180  
have been registered in all provinces and territories in Canada and are marked  
CRN:0F8914.5c.  
Intrinsically Safe, Zone 0/1: EEx ia IIC T4, T5, T6  
Flameproof/Zone 1:  
Non-Sparking, Zone 2:  
Multiple Markings:  
EEx d IIC T5, T6 (enclosure IP 66/67)  
EEx nA, IIC T6 (enclosure IP 66/67)  
Ex II 1 G: EEx ia IIC T4, T5, T6, Ex II 2 G: EExd IIC T5, T6  
Ex II 3 G: EEx nA, IIC T6 (Honeywell) (enclosure IP 66/67)  
ATEX  
Intrinsically Safe: EX ia IIC T4  
Non-Sparking: Ex n IIC T6 (T4 with SM option)  
SA (Australian)  
INMETRO (Brazil)  
Flame-Proof, Zone 1: EX d IIC T5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 10  
Parameter  
Description  
Pressure Equipment Directive  
(97/23/EC)  
The ST 3000 pressure transmitters listed in this Specification have no pressurized  
internal volume or have a pressurized internal volume rated less than 1,000 bar  
(14,500 psig) and/or have a maximum volume of less than 0.1 liter. Therefore,  
these transmitters are either; not subject to the essential requirements of the  
directive 97/23/EC (PED, Annex 1) and shall not have the CE mark, or the  
manufacturer has the free choice of a module when the CE mark is required for  
pressures > 200 bar (2,900 psig).  
*
See Figure 13 for Fill Fluid temperature limits.  
** 2-inch Sanitary Seals are limited to 15 ft. (4.6 m) capillary length.  
NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems) or vessel(s) from  
exceeding allowable pressure limits, (equipment with safety functions in accordance with Pressure Equipment Directive  
97/23/EC article 1, 2.1.3), require separate examination.  
LP Side  
Maximum level  
H2  
Fixed  
ref. leg  
Variable  
Head  
H1  
Minimum level  
.
HP Side  
NOTE: Lower flange seal should not be mounted over 22 feet below the  
transmitter for silicone fill fluid (11 feet for CTFE fill fluid) with tank at one  
atmosphere. The combination of tank vacuum and high pressure capillary  
head effect should not exceed 9 psi vacuum (300 mmHg absolute).  
Consult Honeywell for installation of STR93D  
Figure 16—Typical mounting arrangement for ST 3000 Transmitter with Remote Diaphragm Seals  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 11  
Application Data  
Liquid Level: Closed Tank  
Determine the minimum and  
maximum pressure differentials to  
be measured (Figure 17).  
Max  
LP  
Level  
P
Min  
= (SG x a) - (SG x d)  
p
f
b
= LRV when HP at bottom of  
tank  
Min  
= –URV when LP at bottom of  
tank  
HP  
a
Level  
P
Max  
= (SG x b) - (SG x d)  
p
f
¥ Transmitter above datum  
= URV when HP at bottom of  
tank  
= –LRV when LP at bottom of  
tank  
Max  
LP  
Where:  
Level  
minimum level = 4mA  
maximum level = 20 mA  
b
Min  
a = distance between bottom tap  
and minimum level  
HP  
a
Level  
b = distance between bottom tap  
and maximum level  
¥ Transmitter at datum  
d = distance between taps  
SG = Specific Gravity of capillary  
f
Max  
LP  
fill fluid (See Page 9 for  
values.)  
Level  
SG = Specific Gravity of process  
p
fluid  
b
Min  
HP  
a
Level  
¥ Transmitter below datum  
24253  
Figure 17—Closed tank liquid level measurement distances  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 12  
Density or Interface  
Calculate the minimum and  
maximum pressure differentials to  
be measured (Figure 18).  
P
min  
= (SG  
– SG ) x (d);  
min  
f
minimum density, 4mA output  
LP  
P
max  
= (SG – SG ) x (d);  
max  
f
maximum density, 20mA output  
Where:  
d = distance between the taps  
HP  
SG  
= maximum Specific  
Gravity  
max  
min  
24257  
SG  
= minimum Specific Gravity  
SG = Specific Gravity of capillary  
f
Figure 18—Density, direct acting transmitter configuration  
fill fluid (See Page 9 for  
values.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 13  
Reference Dimensions:millimeters  
Inches  
With  
Smart  
meter  
82.9  
3.26  
94.9  
3.74  
Removal  
Clearance  
for All Caps  
3.6  
0.14  
Plug  
53.1  
2.09  
65.1  
2.56  
135  
5.32  
with meter  
45.7  
1.8  
Without  
Without  
meter  
meter  
55.3  
2.18  
23.5  
.925  
Optional  
Meters  
Optional  
external  
ground  
Rotational  
Lock  
LP seal  
omitted for  
clarity  
67  
2.64  
93.6  
3.69  
STR93D DP/I Remote Seal with Horizontal Pipe Mount  
With  
82.9  
3.26  
94.9  
3.74  
Removal  
Clearance  
Smart  
meter  
3.6  
0.14  
Plug  
for All Caps  
53.1  
2.09  
65.1  
2.56  
135  
5.32  
with meter  
45.7  
1.8  
Without  
Without  
meter  
meter  
55.3  
2.18  
23.5  
.925  
Seal  
omitted for  
clarity  
Optional  
Meters  
Optional  
external  
ground  
Rotational  
Lock  
24272  
STR94G LGP/I Remote Seal with Horizontal Pipe Mount  
Figure 19—Approximate horizontal mounting dimensions for Remote Seal Transmitter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 14  
Reference Dimensions:millimeters  
Inches  
With  
82.9  
94.9  
3.74  
Removal  
Smart  
3.26  
Clearance  
for All Caps  
with meter  
3.6  
0.14  
meter  
Plug  
53.1  
2.09  
65.1  
135  
5.32  
2.56  
45.7  
1.8  
Without  
Without  
meter  
meter  
55.3  
2.18  
Seal  
omitted for  
clarity  
23.5  
.925  
LP seal  
omitted for  
clarity  
Rotational  
Lock  
Optional  
Meters  
Optional  
external  
ground  
67  
2.64  
93.6  
3.69  
STR93D DP/I Remote Seal with Vertical Pipe Mount  
With  
Smart meter  
82.9  
3.26  
94.9  
3.74  
Removal  
3.6  
0.14  
135  
5.32  
Plug  
Clearance  
for All Caps  
with meter  
65.1  
2.56  
53.1  
2.09  
Without  
meter  
45.7  
1.8  
Without  
55.3  
2.18  
meter  
Rotational  
Lock  
23.5  
.925  
Optional  
Meters  
Optional  
external  
ground  
Seal  
omitted for  
clarity  
STR94G LGP/I Remote Seal with Vertical Pipe Mount  
24273  
Figure 20—Approximate vertical mounting dimensions for Remote Seal Transmitter  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 15  
Options  
We are in compliance with the  
Ordering Information  
Mounting Bracket  
Contact your nearest Honeywell sales  
office, or  
The angle-mounting bracket is  
available in either zinc-plated  
carbon steel or stainless steel and  
is suitable for horizontal or vertical  
mounting on a two-inch (50  
millimeter) pipe, as well as wall  
mounting. An optional flat  
mounting bracket is also available  
in carbon steel for two inch (50  
millimeter) pipe mounting.  
following SIL standards:  
IEC 61508-1: 1998;  
IEC 61508-2: 2000;  
IEC 61508-3: 1998  
In the U.S.:  
Honeywell  
NAMUR NE43 Compliance  
(Option NE)  
This option provides software the  
Industrial Automation & Control  
16404 North Black Canyon Hwy.  
Phoenix, AZ 85053  
1-800-288-7491  
meets the NAMUR NE43  
requirements for failsafe software.  
Transmitter failure information is  
generated when the measuring  
information is no longer valid.  
Transmitter failure values are:  
3.6 mA and 21.0 mA. The  
normal ST 3000 ranges are 3.8  
mA and 20.5 mA.  
In Canada:  
The Honeywell Centre  
155 Gordon Baker Rd.  
North York, Ontario M2H 3N7  
1-800-461-0013  
Indicating Meter  
(Options ME and SM)  
Two integral meter options are  
available. An analog meter (option  
ME) is available with a 0 to 100%  
linear scale. The Smart Meter  
(option SM) provides an LCD  
display for both analog and digital  
output and can be configured to  
display pressure in pre-selected  
engineering units.  
In Latin America:  
Honeywell Inc.  
480 Sawgrass Corporate Parkway,  
Suite 200  
Indicator Configuration  
(Option CI)  
Provides custom configuration of  
Smart Meters.  
Sunrise, FL 33325  
(954) 845-2600  
In Europe and Africa:  
Honeywell S. A.  
Tagging (Option TG)  
Lightning Protection  
(Option LP)  
Up to 30 characters can be added  
on the stainless steel nameplate  
mounted on the transmitter’s  
electronics housing at no extra  
cost. Note that a separate  
nameplate on the meter body  
contains the serial number and  
body-related data. A stainless  
steel wired on tag with additional  
data of up to 4 lines of 28  
Avenue du Bourget 1  
1140 Brussels, Belgium  
A terminal block with circuitry that  
protects the transmitter from  
transient surges induced by  
nearby lightning strikes is  
available.  
In Eastern Europe:  
Honeywell Praha,  
s.r.o. Budejovicka 1  
140 21 Prague 4,  
Czech Republic  
HART® Protocol Compatibility  
(Options HC and H6)  
Optional electronics modules for  
the ST 3000 provides HART  
Protocol compatibility in either  
HART 5.x or 6.x formats.  
In the Middle East:  
Honeywell Middle East Ltd.  
Khalifa Street,  
characters is also available. The  
number of characters for tagging  
includes spaces.  
Sheikh Faisal Building  
Abu Dhabi, U. A. E.  
Transmitters with a HART Option  
are compatible with any HART  
enabled system that provides 5.x  
or 6.x format support.  
Transmitter Configuration  
(Option TC)  
In Asia:  
Honeywell Asia Pacific Inc.  
Honeywell Building,  
17 Changi Business Park Central 1  
Singapore 486073  
The factory can configure the  
transmitter linear/square root  
extraction, damping time, LRV,  
URV and mode (analog/digital)  
and enter an ID tag of up to eight  
characters and scratchpad  
information as specified.  
FOUNDATION Fieldbus  
(Option FF)  
Republic of Singapore  
Equips transmitter with FF  
protocol for use in 31.25 kbit/s FF  
networks. See document 34-ST-  
03-72 for additional information on  
ST 3000 Fieldbus transmitters.  
In the Pacific:  
Honeywell Pty Ltd.  
5 Thomas Holt Drive  
North Ryde NSW Australia 2113  
(61 2) 9353 7000  
Custom Calibration and ID in  
Memory (Option CC)  
The factory can calibrate any  
range within the scope of the  
transmitter’s range and enter an  
ID tag of up to eight characters in  
the transmitter’s memory.  
SIL2/SIL3 Certification  
(Option SL)  
In Japan:  
Honeywell K.K.  
This ST 3000 product is available  
for use with safety systems. With  
the SL option, we are fully certified  
to SIL 2 capability for single  
transmitters and SIL 3 capability for  
multiple transmitter use through  
TÜV Nord Sys Tec GmbH & Co.  
KG. (continued)  
14-6 Shibaura 1-chrome  
Minato-ku, Tokyo, Japan 105-0023  
Or, visit Honeywell on the World Wide  
Specifications are subject to change without  
notice. (Note that specifications may differ  
slightly for transmitters manufactured before  
October 30, 1995.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 16  
Model Selection Guide (34-ST-16-34)  
Instructions  
Select the desired Key Number. The arrow to the right marks the selection available.  
Make one selection from each table, I and II, using the column below the proper arrow.  
Select as many Table III options as desired (if no options are desired, specify 9X).  
A () denotes unrestricted availability. A letter denotes restricted availability.  
Restrictions follow Table IV.  
I
II  
III (Optional)  
IV  
Key Number  
_ _ _ _ _ _  
-
_ _ _  
- _ _ _ _ _ _ _ _ _ _ _ _  
-
_ _, _ _, _ _  
+
XXXX  
KEY NUMBER  
Selection  
Avail.  
Description  
0-25" to 0-2700" H2O/0-62.2 to 0-7000 mbar  
STR93D  
Body Rating*: 750 psi (51.7 bar) Compound Characterized  
0-20 to 0-500 psig/0-1.4 to 0-35 bar  
STR94G  
Body Rating*: 500 psi (35 bar)  
* Remote seal system pressure rating is body rating or seal rating, whichever is less.  
TABLE I - METER BODY  
Description  
Selection  
1 _ _  
2 _ _  
3 _ _  
5 _ _  
Avail.  
1 Remote Seal (High Side)  
2 Remote Seals  
1 Remote Seal (Low Side)  
Number of Seals  
8
Value Added Model (VAM unit)  
Silicone (DC 200)  
Fill Fluid (Meter Body)  
CTFE  
8
_ 1 _  
_ 2 _  
q
q
Non-Wetted Material  
Construction  
316 SS  
_ _ A  
_ _ D  
_ _ A  
_ _ D  
_ _ C  
y
In-Line Gauge  
316 SS for Close-Couple  
316 SS Heads  
y
7
Dual Head DP  
316 SS Heads for Close-Couple connection  
316 SS with all-welded meter body  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 17  
TABLE II - SEALS  
Format for Seal Selection:  
Specify 12 characters  
Availability  
_ _ _ _ _ _ _ _ _ _ _ _  
Common Required Seal  
STR9xx  
Note:  
The first 3 characters are common to all seals.  
When selecting required seal, you must specify  
3D 4G  
Selection  
only the 9 selections within the required seal.  
No Fill Fluid  
Silicone (DC 200)  
CTFE  
Silicone (DC 704)  
Neobee (M20) **  
Syltherm 800 ***  
0 _ _ _ _ _ _ _ _ _ _ _  
1 _ _ _ _ _ _ _ _ _ _ _  
2 _ _ _ _ _ _ _ _ _ _ _  
3 _ _ _ _ _ _ _ _ _ _ _  
4 _ _ _ _ _ _ _ _ _ _ _  
5 _ _ _ _ _ _ _ _ _ _ _  
3
p
3
p
Secondary Fill  
p
p
No Capillary, No Nipple  
_ 0 _ _ _ _ _ _ _ _ _ _  
_ A _ _ _ _ _ _ _ _ _ _  
_ B _ _ _ _ _ _ _ _ _ _  
_ C _ _ _ _ _ _ _ _ _ _  
_ D _ _ _ _ _ _ _ _ _ _  
_ E _ _ _ _ _ _ _ _ _ _  
_ F _ _ _ _ _ _ _ _ _ _  
_ G _ _ _ _ _ _ _ _ _ _  
_ H _ _ _ _ _ _ _ _ _ _  
_ J _ _ _ _ _ _ _ _ _ _  
_ K _ _ _ _ _ _ _ _ _ _  
_ L _ _ _ _ _ _ _ _ _ _  
_ M _ _ _ _ _ _ _ _ _ _  
3
3
5 feet  
10 feet  
15 feet  
20 feet  
25 feet  
35 feet  
5 feet  
1.5 m  
3.0 m  
4.5 m  
6.1 m  
7.5 m  
10.7 m  
1.5 m  
3.0 m  
4.5 m  
6.1 m  
7.5 m  
10.7 m  
z
z
SS Armor  
Connection of  
Remote Seal to  
Meter Body  
Capillary  
Length  
10 feet  
15 feet  
20 feet  
25 feet  
35 feet  
PVC Coated SS Armor  
2 inch long SS nipple close-coupled  
_ 2 _ _ _ _ _ _ _ _ _ _  
_ _ 0 _ _ _ _ _ _ _ _ _  
_ _ _ 0 0 0 0 0 0 0 0 0  
No Selection  
3
3
No Seal Attached to Core Transmitter  
Diaphragm  
Diameter  
Flange Size  
Flange Pressure Rating *  
Selection  
ANSI Class 150  
ANSI Class 300  
DIN DN80-PN40  
_ _ _ AFA _ _ _ _ _ _  
_ _ _ AFC _ _ _ _ _ _  
_ _ _ AFM _ _ _ _ _ _  
Selection  
3.5"  
3"  
Diaphragm  
Upper Insert  
316 SS  
316L SS  
Hastelloy C  
Hastelloy C  
Monel  
_ _ _ _ _ _ AA _ _ _ _  
_ _ _ _ _ _ AB _ _ _ _  
_ _ _ _ _ _ AC _ _ _ _  
_ _ _ _ _ _ AE _ _ _ _  
_ _ _ _ _ _ AF _ _ _ _  
_ _ _ _ _ _ _ _ 1 _ _ _  
_ _ _ _ _ _ _ _ 2 _ _ _  
_ _ _ _ _ _ _ _ _ 1 _ _  
_ _ _ _ _ _ _ _ _ 2 _ _  
_ _ _ _ _ _ _ _ _ _ A _  
_ _ _ _ _ _ _ _ _ _ B _  
_ _ _ _ _ _ _ _ _ _ C _  
_ _ _ _ _ _ _ _ _ _ D _  
Table II continued next page  
1
1
316 SS  
Wetted Material  
Flange Material  
Hastelloy C  
Monel  
Flush Flanged  
Seal  
Tantaluma  
Tantalum  
CS (Nickel Plated)  
316 SS  
Center of Seal  
Side of Seal  
None  
Seal-Capillary  
Connection  
9
9
316 SS  
5
5
5
5
5
5
Calibration Rings  
Hastelloy C  
Monel  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 18  
Availability  
3D 4G  
STR9xx  
TABLE II - SEALS (continued)  
Description  
Selection  
Flushing  
None  
_ _ _ _ _ _ _ _ _ _ _ 0  
_ _ _ _ _ _ _ _ _ _ _ H  
_ _ _ _ _ _ _ _ _ _ _ J  
_ _ _ _ _ _ _ _ _ _ _ M  
_ _ _ _ _ _ _ _ _ _ _ N  
_ _ _ _ _ _ _ _ _ _ _ P  
_ _ _ _ _ _ _ _ _ _ _ Q  
_ _ _ _ _ _ _ _ _ _ _ R  
_ _ _ _ _ _ _ _ _ _ _ S  
Table II continued below  
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Connections  
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
and Plugs**  
Metal plug material  
will be the same as  
Lower material, if  
metal plug is chosen -  
(SS Plug for CS Lower  
and Tantalum Clad)  
Flush Flanged  
Seal  
*
**  
Standard facing 125-250 AARH RF (raised face) serrated surface finish.  
Limited vacuum availability.  
***  
****  
a
Minimum static pressure requirement. No vacuum allowed. See Specification Figure 13.  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
Tantalum Upper insert has Tantalum wetted parts and 316SS or CS non-wetted parts  
STR9xx  
3D 4G  
TABLE II - SEALS (continued)  
Const. - See  
Spec. Figure 34-  
Diaphragm  
Diameter  
Flange Pressure  
Rating *  
Flange Size  
Selection  
ST-03-57  
22  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
ANSI  
150  
300  
150  
300  
150  
300  
150  
300  
150  
150  
300  
150  
300  
150  
300  
150  
150  
300  
150  
300  
150  
300  
150  
300  
_ _ _ BCA _ _ _ _ _ _  
_ _ _ BCC _ _ _ _ _ _  
_ _ _ BGA _ _ _ _ _ _  
_ _ _ BGC _ _ _ _ _ _  
_ _ _ BDA _ _ _ _ _ _  
_ _ _ BDC _ _ _ _ _ _  
_ _ _ BFA _ _ _ _ _ _  
_ _ _ BFC _ _ _ _ _ _  
_ _ _ CAA _ _ _ _ _ _  
_ _ _ CCA _ _ _ _ _ _  
_ _ _ CCC _ _ _ _ _ _  
_ _ _ CGA _ _ _ _ _ _  
_ _ _ CGC _ _ _ _ _ _  
_ _ _ CDA _ _ _ _ _ _  
_ _ _ CDC _ _ _ _ _ _  
_ _ _ DAA _ _ _ _ _ _  
_ _ _ DCA _ _ _ _ _ _  
_ _ _ DCC _ _ _ _ _ _  
_ _ _ DGA _ _ _ _ _ _  
_ _ _ DGC _ _ _ _ _ _  
_ _ _ DDA _ _ _ _ _ _  
_ _ _ DDC _ _ _ _ _ _  
_ _ _ DFA _ _ _ _ _ _  
_ _ _ DFC _ _ _ _ _ _  
1"  
1-1/2"  
2"  
22  
22  
22  
22  
22  
22  
22  
23  
23  
23  
22  
22  
2.4"  
3"  
1/2"  
1"  
2.9"  
Flush Flanged  
Seal with Lower  
1-1/2"  
2"  
22  
22  
1/2"  
1"  
23  
23  
23  
23  
23  
23  
22  
22  
1-1/2"  
2"  
4.1"  
3"  
22  
Table II continued next page  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 19  
Availability  
3D 4G  
STR9xx  
TABLE II - SEALS (continued)  
Diaphragm  
316L SS  
Hastelloy C  
Hastelloy C  
Monel  
Lower  
316 SS  
Selection  
_ _ _ _ _ _ BA _ _ _ _  
_ _ _ _ _ _ BB _ _ _ _  
_ _ _ _ _ _ BC _ _ _ _  
_ _ _ _ _ _ BE _ _ _ _  
_ _ _ _ _ _ BF _ _ _ _  
_ _ _ _ _ _ BG _ _ _ _  
_ _ _ _ _ _ BH _ _ _ _  
Selection  
316 SS  
Hastelloy C  
Monel  
Wetted Material  
Tantalum  
Tantalum  
Tantalum  
Upper  
316 SS  
1
1
Hastelloy C  
Tantalum Clad  
Upper Insert  
316 SS  
1
1
10 10  
Non-Wetted Material  
(upper, upper insert)  
316 SS  
_ _ _ _ _ _ _ _ 4 _ _ _  
_ _ _ _ _ _ _ _ 5 _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _ _ _ _ _ H _  
_ _ _ _ _ _ _ _ _ _ J _  
_ _ _ _ _ _ _ _ _ _ M _  
_ _ _ _ _ _ _ _ _ _ N _  
_ _ _ _ _ _ _ _ _ _ P _  
_ _ _ _ _ _ _ _ _ _ Q _  
_ _ _ _ _ _ _ _ _ _ R _  
_ _ _ _ _ _ _ _ _ _ S _  
_ _ _ _ _ _ _ _ _ _ _ K  
Carbon Steel  
316 SS  
Bolts***  
Flushing  
No Selection  
Flush Flanged  
Seal with Lower  
(continued)  
None  
c
c
Connections  
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
Klinger C-4401  
and Plugs**  
Metal plug material  
will be the same as  
Lower material, if  
metal plug is chosen -  
(SS Plug for CS Lower  
and Tantalum Clad)  
(non-asbestos)  
Gasket  
Grafoil  
_ _ _ _ _ _ _ _ _ _ _ G  
_ _ _ _ _ _ _ _ _ _ _ T  
_ _ _ _ _ _ _ _ _ _ _ L  
c
d
c
d
Teflon  
Gylon 3510  
Diaphragm  
Flange Size  
Diameter  
Flange Pressure Rating *  
Selection  
ANSI Class 150  
ANSI Class 300  
DIN DN80-PN40  
ANSI Class 150  
ANSI Class 300  
DIN DN100-PN40  
3"  
(2.8" OD  
_ _ _ EFA _ _ _ _ _ _  
_ _ _ EFC _ _ _ _ _ _  
_ _ _ EFM _ _ _ _ _ _  
_ _ _ FGA _ _ _ _ _ _  
_ _ _ FGC _ _ _ _ _ _  
_ _ _ FGP _ _ _ _ _ _  
Selection  
2.8"  
3.5"  
extension)  
4"  
(3.70" OD  
extension)  
Diaphragm  
316L SS  
Ext. Tube  
316 SS  
Flange Seal with  
Extended  
Diaphragm  
_ _ _ _ _ _ EA _ _ _ _  
_ _ _ _ _ _ EB _ _ _ _  
_ _ _ _ _ _ EC _ _ _ _  
_ _ _ _ _ _ _ _ 7 _ _ _  
_ _ _ _ _ _ _ _ 8 _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 2 _  
_ _ _ _ _ _ _ _ _ _ 4 _  
_ _ _ _ _ _ _ _ _ _ 6 _  
Wetted Material  
Hastelloy C  
Hastelloy C  
316 SS  
Hastelloy C  
CS (Nickel Plated)  
Flange Material  
Bolts  
316 SS  
No Selection  
2"  
4"  
6"  
Extension Length  
No Selection  
No Selection  
_ _ _ _ _ _ _ _ _ _ _ 0  
Table II continued next page  
Standard facing 125-250 AARH RF (raised face) serrated finish.  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
*
**  
Bolt material will be same as Upper Material. However, if Table III bolt/nut option chosen, seal bolt material will be the same.  
***  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 20  
STR9xx  
3D 4G  
TABLE II - SEALS (continued)  
Diaphragm  
Diameter  
Flange Pressure Rating Dependent  
on Customer Flange  
Flange Size  
Selection  
ANSI Class 150/300/600  
3.5"  
3"  
_ _ _ GFA _ _ _ _ _ _  
Selection  
Diaphragm  
316L SS  
Body  
316 SS  
_ _ _ _ _ _ GA _ _ _ _  
_ _ _ _ _ _ GB _ _ _ _  
_ _ _ _ _ _ GC _ _ _ _  
_ _ _ _ _ _ GE _ _ _ _  
_ _ _ _ _ _ GG _ _ _ _  
_ _ _ _ _ _ _ _ 0 _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ A _  
_ _ _ _ _ _ _ _ _ _ B _  
_ _ _ _ _ _ _ _ _ _ C _  
_ _ _ _ _ _ _ _ _ _ D _  
_ _ _ _ _ _ _ _ _ _ _ 0  
_ _ _ _ _ _ _ _ _ _ _ H  
_ _ _ _ _ _ _ _ _ _ _ J  
_ _ _ _ _ _ _ _ _ _ _ M  
_ _ _ _ _ _ _ _ _ _ _ N  
_ _ _ _ _ _ _ _ _ _ _ P  
_ _ _ _ _ _ _ _ _ _ _ Q  
_ _ _ _ _ _ _ _ _ _ _ R  
_ _ _ _ _ _ _ _ _ _ _ S  
Table II continued below  
1
1
Hastelloy C  
Hastelloy C  
Monel  
316 SS  
Wetted Material  
Hastelloy C  
Monel  
Tantaluma  
Tantalum  
Non-Wetted Materials  
No Selection  
No Selection  
No Selection  
None  
5
5
5
5
5
5
316 SS  
Pancake Seal  
Calibration Rings  
Hastelloy C  
Monel  
Flushing  
None  
6
6
6
6
6
6
6
6
Connections  
6
6
6
6
6
6
6
6
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
and Plugs**  
Metal plug material  
will be the same as  
Lower material, if  
metal plug is chosen -  
(SS Plug for CS Lower  
and Tantalum Clad)  
a
Tantalum Body has Tantalum wetted parts and 316SS non-wetted parts  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
***  
STR9xx  
3D 4G  
TABLE II - SEALS (continued)  
Diaphragm  
Flange Size  
Flange Pressure Rating  
Selection  
Diameter  
Taylor  
Wedge 5"  
O.D.  
v
3.5"  
750 psi  
_ _ _ HM0 _ _ _ _ _ _  
Diaphragm  
Body  
316 SS  
316 SS  
Selection  
316L SS  
Hastelloy C  
Hastelloy C  
_ _ _ _ _ _ HA _ _ _ _  
_ _ _ _ _ _ HB _ _ _ _  
_ _ _ _ _ _ HC _ _ _ _  
Wetted Material  
Chemical Tee  
"Taylor" Wedge  
Hastelloy C  
Non-Wetted Material  
Bolts  
No Selection  
_ _ _ _ _ _ _ _ 0 _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _ _ _ _ _ _ 0  
No Selection  
No Selection  
No Selection  
Styles  
No Selection  
Table II continued next page  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 21  
Availability  
3D 4G  
STR9xx  
TABLE II - SEALS (continued)  
Seal Pressure  
Rating *  
Threaded Process  
Connection Size  
Diaphragm  
Diameter  
(NPT  
Selection  
304 SS  
C.S. Bolts  
Female)  
Bolts  
1/2" NPT  
3/4" NPT  
1" NPT  
_ _ _ JJG _ _ _ _ _ _  
_ _ _ JKG _ _ _ _ _ _  
_ _ _ JLG _ _ _ _ _ _  
_ _ _ KJG _ _ _ _ _ _  
_ _ _ KKG _ _ _ _ _ _  
_ _ _ KLG _ _ _ _ _ _  
_ _ _ LJG _ _ _ _ _ _  
_ _ _ LKG _ _ _ _ _ _  
_ _ _ LLG _ _ _ _ _ _  
Selection  
2.4"  
2.9"  
4.1"  
2500 psi 1250 psi  
1/2" NPT  
3/4" NPT  
1" NPT  
2500 psi 1250 psi  
1500 psi 750 psi  
1/2" NPT  
3/4" NPT  
1" NPT  
Diaphragm  
Lower  
Carbon Steel  
316 SS  
316L SS  
316L SS  
_ _ _ _ _ _ JA _ _ _ _  
_ _ _ _ _ _ JB _ _ _ _  
_ _ _ _ _ _ JC _ _ _ _  
_ _ _ _ _ _ JD _ _ _ _  
_ _ _ _ _ _ JE _ _ _ _  
_ _ _ _ _ _ JF _ _ _ _  
_ _ _ _ _ _ JG _ _ _ _  
_ _ _ _ _ _ _ _ A _ _ _  
_ _ _ _ _ _ _ _ C _ _ _  
_ _ _ _ _ _ _ _ _ C _ _  
_ _ _ _ _ _ _ _ _ D _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _ _ _ _ _ H _  
_ _ _ _ _ _ _ _ _ _ J _  
_ _ _ _ _ _ _ _ _ _ M _  
_ _ _ _ _ _ _ _ _ _ N _  
_ _ _ _ _ _ _ _ _ _ P _  
_ _ _ _ _ _ _ _ _ _ Q _  
_ _ _ _ _ _ _ _ _ _ R _  
_ _ _ _ _ _ _ _ _ _ S _  
_ _ _ _ _ _ _ _ _ _ _ K  
1
1
1
1
Hastelloy C  
Hastelloy C  
Monel  
316 SS  
Wetted Material  
Hastelloy C  
Monel  
Tantalum  
Tantalum  
316 SS  
Hastelloy C  
Seal with  
Threaded  
Process  
CS (Nickel Plated)  
Non-Wetted Material  
(upper)  
w
1
w
1
Stainless Steel  
Carbon Steel  
304 SS  
Connection  
Bolts***  
Flushing  
Connections  
and Plugs**  
None  
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
Klinger C-4401  
Metal plug material  
will be the same as  
Lower material, if  
metal plug is chosen -  
(SS Plug for CS Lower  
and Tantalum Clad)  
11 11  
11 11  
11 11  
11 11  
c
c
(non-asbestos)  
Grafoil  
Gasket  
_ _ _ _ _ _ _ _ _ _ _ G  
_ _ _ _ _ _ _ _ _ _ _ T  
_ _ _ _ _ _ _ _ _ _ _ L  
c
c
Teflon  
Gylon 3510  
d
d
Table II continued next page  
* Caution:  
Maximum working pressure of STR93D transmitter is 750 psi and STR94G transmitter  
is 500 psig. Damage to sensor may result if pressure limit is exceeded.  
**  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
If Table III Bolt/Nut option is chosen, Seal bolts will ship as same material, and MAWP may change.  
***  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 22  
STR9xx  
3D 4G  
TABLE II - SEALS (continued)  
Diaphragm  
Diameter  
Flange Size  
Pressure Rating  
Selection  
g
1.9"  
2.4"  
2.9"  
4.1"  
2"  
2-1/2"  
3"  
_ _ _ MD0 _ _ _ _ _ _  
_ _ _ NE0 _ _ _ _ _ _  
_ _ _ PF0 _ _ _ _ _ _  
_ _ _ QG0 _ _ _ _ _ _  
Selection  
Customer clamp rating or 600 psi,  
whichever is less  
4"  
Diaphragm  
Body  
Wetted Material  
Sanitary Seal  
316L SS  
316 SS  
_ _ _ _ _ _ N A _ _ _ _  
Non-Wetted Material  
No Selection  
_ _ _ _ _ _ _ _ 0 _ _ _  
Bolts  
Styles  
Gasket  
No Selection  
Tri-Clover Tri-Clamp  
No Selection  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 8 _  
_ _ _ _ _ _ _ _ _ _ _ 0  
Seal Pressure Rating * *  
Diaphragm  
Size and  
Selection  
Diameter Bolt Pattern  
C.S. Bolts  
304 SS Bolts  
2.4"  
_ _ _ RFK _ _ _ _ _ _  
_ _ _ RGK _ _ _ _ _ _  
_ _ _ RPK _ _ _ _ _ _  
_ _ _ RQK _ _ _ _ _ _  
for 3" Pipe ?  
8-Bolt  
1500 psi  
1250 psi  
1500 psi  
4" pipe  
Design  
2.4"  
for 3" Pipe ?  
6-Bolt  
1250 psi  
4" pipe  
Design  
Selection  
Diaphragm  
316L SS  
Lower Housing  
Carbon Steel  
316 SS  
_ _ _ _ _ _ RA _ _ _ _  
_ _ _ _ _ _ RB _ _ _ _  
_ _ _ _ _ _ RC _ _ _ _  
_ _ _ _ _ _ RD _ _ _ _  
_ _ _ _ _ _ SB _ _ _ _  
_ _ _ _ _ _ SC _ _ _ _  
Selection  
316L SS  
Wetted Material  
Hastelloy C  
Hastelloy C  
316L SS  
316 SS  
Saddle Seal  
Hastelloy C  
N/A-Body Only  
N/A-Body Only  
Bolts *, ***  
Hastelloy C  
Body  
Non-Wetted Material  
Carbon Steel  
304 SS  
1
1
Carbon Steel  
316 SS  
_ _ _ _ _ _ _ _ B _ _ _  
_ _ _ _ _ _ _ _ C _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _ _ _ _ _ _ K  
No Selection  
Styles  
No Selection  
No Selection  
Klinger C-4401  
(non-asbestos)  
Grafoil  
Gasket  
_ _ _ _ _ _ _ _ _ _ _ G  
_ _ _ _ _ _ _ _ _ _ _ T  
_ _ _ _ _ _ _ _ _ _ _ L  
Teflon  
Gylon 3510  
*
Bolts are not included with "Body only" selection.  
Caution: Maximum working pressure of STR93D transmitter is 750 psi and STR94G transmitter  
is 500 psig. Damage to sensor may result if pressure limit is exceeded.  
**  
***  
If Table III Bolt/Nut option is chosen, Seal bolts will ship as same material, and MAWP may change.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 23  
STR9xx  
3D 4G  
TABLE III - OPTIONS  
Selection  
None  
00  
Communication Options  
HART 5.x Protocol Compatible Electronics  
HART 6.x Protocol Compatible Electronics  
FOUNDATION Fieldbus Communications  
Indicating Meter Options  
Analog Meter (0-100 Even 0-10 Square Root)  
Smart Meter  
Custom Configuration of Smart Meter  
Local Zero  
Local Zero and Span  
HC  
H6  
FF  
e
e
r
e
e
r
b
b
ME  
SM  
CI  
LZ  
ZS  
m
x
s
m
x
s
Transmitter Housing & Electronics Options  
NAMUR Failsafe Software  
SIL 2 - TÜV Certified transmitter (requires HC and WP options)  
Lightning Protection  
Custom Calibration and I.D. in Memory  
Transmitter Configuration  
15 15  
14 14  
NE  
SL  
LP  
CC  
TC  
WP  
WX  
SH  
A1  
Write Protection (Delivered in the "enabled" position)  
Write Protection (Delivered in the "disabled" position)  
316 SS Electronics Housing - with M20 Conduit Connections  
1/2" NPT to M20 316SS Conduit Adapter (BASEEFA EEx d IIC)  
1/2" NPT to 3/4" NPT 316 SS Conduit Adapter  
Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit  
Adapter (use for FM and CSA Approvals)  
Stainless Steel Customer Wired-On Tag  
(4 lines, 28 characters per line, customer supplied information)  
Stainless Steel Customer Wired-On Tag (blank)  
End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)  
End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)  
End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)  
End Cap Live Circuit Warning Label in German (only with ATEX 3D)  
Meter Body Options (Seal bolt material depends on Transmitter bolt material)  
A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads  
316 SS Bolts and 316 SS Nuts for Process Heads  
B7M Bolts and Nuts for Process Heads  
Remote Seal Options  
b
b
n
n
u
i
n
n
u
i
A2  
A3  
TG  
TB  
SP  
PG  
TL  
a
a
a
a
a
a
a
a
b
GE  
CR  
SS  
B7  
b
Gold Plated Seal Diaphragm (1 Seal)  
G1  
G2  
N1  
N2  
j
j
j
j
j
j
Gold Plated Seal Diaphragm (2 Seals)  
Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking  
Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking  
Transmitter Mounting Brackets Options  
Mounting Bracket - Carbon Steel  
b
b
MB  
SB  
FB  
Mounting Bracket - 304 SS  
Flat Mounting Bracket  
Services/Certificates Options  
UM  
0X  
TP  
F1  
F3  
F5  
F6  
F7  
F8  
MT  
Users Manual Paper Copy (Standard, HC or FF ships accordingly)  
Clean Transmitter & Seals for Oxygen or Chlorine Service with Certificate  
Over-Pressure Leak Test with F3392 Certificate  
Calibration Test Report and Certificate of Conformance (F3399)  
Certificate of Conformance (F3391)  
Certificate of Origin (F0195)  
FMEDA Certificate (SIL 1)  
NACE Certificate (F0198)  
h
o
16  
2
h
b
b
NACE Certificate (F0198) for welded meter bodies only  
Marine Type Approvals (DNV, ABS, BV & LR)  
Warranty Options  
2
Additional Warranty - 1 year  
Additional Warranty - 2 years  
Additional Warranty - 3 years  
Additional Warranty - 4 years  
W1  
W2  
W3  
W4  
b
Table III continued next page  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 24  
STR9xx  
3D 4G  
TABLE III - OPTIONS (continued)  
Approval  
Body  
Approval Type  
Location or Classification  
Selection  
No hazardous location approvals  
Explosion Proof  
9X  
Class I, Div. 1, Groups A,B,C,D  
Dust Ignition Proof  
Non-Incendive  
Class II, III Div. 1, Groups E,F,G  
Class I, Div. 2, Groups A,B,C,D  
Class I, II, III, Div. 1, Groups  
A,B,C,D,E,F,G  
Factory  
Mutual  
1C  
2J  
Intrinsically Safe  
Explosion Proof  
Class I, Div. 1, Groups B,C,D  
Class II, III, Div. 1, Groups E,F,G  
Class I, II, III, Div. 1, Groups  
A,B,C,D,E,F,G  
Dust Ignition Proof  
CSA  
Intrinsically Safe  
Intrinsically Safe  
Non-Sparking  
Intrinsically Safe,  
Zone 0/1  
Ex ia IIC T4  
SA  
(Australia)  
4G  
3S  
3D  
3N  
Ex n IIC T6 (T4 with SM option)  
b
EEx ia IIC T4, T5,T6  
EEx d IIC T5, T6,  
Enclosure IP 66/67  
Flameproof, Zone 1  
EEx nA, IIC T6  
Non-Sparking,  
Zone 2  
ATEX*  
(Honeywell). Enclosure IP 66/67  
Ex II 1 G EEx ia IIC T4, T5, T6  
Ex II 2 G EEx d IIC T5, T6  
Ex II 3 G EEx nA, IIC T6 (Honeywell)  
Enclosure IP 66/67  
Multiple Marking**  
Int. Safe, Zone 0/1, or  
Flameproof, Zone 1, or  
Non-Sparking, Zone 2  
3H  
6D  
INMETRO  
(Brazil)  
Flameproof, Zone 1  
Ex d IIC T5  
*See ATEX installation requirements in the ST 3000 User's Manual  
**The user must determine the type of protection required for installation of the equipment. The user shall then check the box []  
adjacent to the type of protection used on the equipment certification nameplate. Once a type of protection has been checked on  
the nameplate, subsequently the equipment shall not be reinstalled using any of the other certification types.  
TABLE IV  
Factory Identification  
XXXX  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 25  
RESTRICTIONS  
Available Only With  
Selection  
Not Available With  
Selection  
Restriction  
Letter  
Table  
Table  
a
b
III  
3D or 3H  
Select only one option from this group  
_ _ _ _ _ _ BF _ _ _ _,  
_ _ _ _ _ _ BG _ _ _ _,  
_ _ _ _ _ _ BH _ _ _ _,  
_ _ _ _ _ _ JF _ _ _ _,  
_ _ _ _ _ _ JG _ _ _ _,  
c
II  
_ _ _ _ _ _ BF _ _ _ _,  
_ _ _ _ _ _ BG _ _ _ _,  
_ _ _ _ _ _ JF _ _ _ _,  
_ _ _ _ _ _ JG _ _ _ _,  
II  
II  
d
e
III  
4G  
_ A _ _ _ _ _ _ _ _ _ _,  
_ B _ _ _ _ _ _ _ _ _ _,  
_ C _ _ _ _ _ _ _ _ _ _,  
_ G _ _ _ _ _ _ _ _ _ _,  
_ H _ _ _ _ _ _ _ _ _ _,  
_ J _ _ _ _ _ _ _ _ _ _,  
_ 2 _ _ _ _ _ _ _ _ _ _,  
g
h
i
I, II  
III  
_ 2 _ - 2 _ _ _ _ _ _ _ _ _ _ _  
1C or 2J  
_ _ _ _ _ _ AF _ _ _ _  
_ _ _ _ _ _ BF _ _ _ _  
_ _ _ _ _ _ BG _ _ _ _  
_ _ _ _ _ _ BH _ _ _ _  
_ _ _ _ _ _ GG _ _ _ _  
_ _ _ _ _ _ JF _ _ _ _  
_ _ _ _ _ _ JG _ _ _ _  
j
II  
III  
III  
SM  
CR  
m
n
o
III  
1C, 2J  
DC704 and Syltherm 800  
fills and close-couple require  
SS seal upper.  
_ _ _ BCA _ _ 5 _ _ _,  
_ _ _ CAA _ _ 5 _ _ _,  
_ _ _ CCA _ _ 5 _ _ _,  
_ _ _ CCC _ _ 5 _ _ _,  
_ _ _ DAA _ _ 5 _ _ _,  
_ _ _ DCA _ _ 5 _ _ _,  
_ _ _ DCC _ _ 5 _ _ _,  
_ _ _ DGA _ _ 5 _ _ _,  
_ _ _ DGC _ _ 5 _ _ _,  
_ _ _ DDA _ _ 5 _ _ _,  
_ _ _ _ _ _ GE _ _ _ _,  
_ _ _ _ _ _ _ _ A _ _ _  
_ _ _ _ _ _ _ _ B _ _ _  
II  
p
0 _ _ _ _ _ _ _ _ _ _ _ _,  
2 _ _ _ _ _ _ _ _ _ _ _ _,  
4 _ _ _ _ _ _ _ _ _ _ _ _  
q
II  
III  
III  
r
TC, ME, 4G, 3S  
FF, ME  
s
Restrictions continued next page  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 26  
RESTRICTIONS - (continued)  
Restriction  
Letter  
Available Only With  
Selection  
Not Available With  
Selection  
Table  
Table  
III  
u
v
1C, 2J  
I
2 _ _  
II  
w
x
_ _ _ _ _ _ JA _ _ _ _  
III  
FF, SM  
III  
MB, SB, FB  
DC704 and Syltherm 800  
fills and close-couple require  
SS seal upper.  
_ _ _ BCA _ _ 5 _ _ _,  
_ _ _ CAA _ _ 5 _ _ _,  
_ _ _ CCA _ _ 5 _ _ _,  
_ _ _ CCC _ _ 5 _ _ _,  
_ _ _ DAA _ _ 5 _ _ _,  
_ _ _ DCA _ _ 5 _ _ _,  
_ _ _ DCC _ _ 5 _ _ _,  
_ _ _ DGA _ _ 5 _ _ _,  
_ _ _ DGC _ _ 5 _ _ _,  
_ _ _ DDA _ _ 5 _ _ _,  
_ _ _ _ _ _ GE _ _ _ _,  
_ _ _ _ _ _ _ _ A _ _ _  
y
_ _ _ _ _ _ _ _ B _ _ _  
2 _ _  
I
II  
_ A - M _ _ _ _ _ _ _ _ _ _  
I
I
z
1
2
3
5
6
_ _ D  
III  
III  
F7  
FB  
5 _ _, 1 _ _  
II  
II  
_ _ _ _ _ _ _ _ _ _ _ 0  
_ _ _ _ _ _ _ _ _ _ A _  
1 _ _, 3 _ _  
I
7
III  
III  
CR  
8
9
CC,G1,G2,T1,T2,OX,TP,MT,WP  
_ _ _ _ _ _ AA2_ _ _  
_ _ _ _ _ _ AB2_ _ _  
II  
II  
II  
III  
_ _ _ _ _ _ _ _ _ _ _ T  
F7  
_ _ _ _ _ _ _ _ _ _ 0 _  
10  
_ _ _ _ _ _JJG_ _ _  
_ _ _ _ _ _JKG_ _ _  
_ _ _ _ _ _JLG_ _ _  
_ _ _ _ _ _CAA_ _ _  
_ _ _ _ _ _CCA_ _ _  
_ _ _ _ _ _CCC_ _ _  
FF, 00  
II  
11  
HC, WP  
_ _ C  
III  
III  
14  
15  
16  
III  
I
FF  
See ST-83 for Published Specials with pricing.  
See ST-89 and User's Manual for part numbers.  
Notes:  
See COMS Order Entry Information including TC, manuals, certificates, drawings and SPINS.  
See ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including factory default values.  
To request a quotation for a non-published "special", fax RFQ with Application Data Sheet (34-ST-18-01) to Marketing Applications.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 27  
Dimensions and drawings  
21a  
21b  
21b  
21a  
21a  
21a  
21a  
21b  
21b  
21a  
21a  
21a  
21a  
21b  
21b  
21a  
21a  
21a  
21a  
21b  
21b  
21a  
21a  
21a  
Figure 21a. Flush Flanged Seal  
Figure 21b. Flush Flanged Seal  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 28  
Dimensions and drawings, cont.  
Figure 22  
Figure 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 29  
Dimensions and drawings, cont.  
Figure 24  
Figure 25  
Figure 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 30  
Dimensions and drawings, cont.  
Figure 27  
Figure 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 31  
Dimensions and drawings, cont.  
Figure 29  
Figure 30  
Figure 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-57  
Page 32  
ST 3000® is a registered trademark of Honeywell International Inc.  
HART* is a trademark of the Hart Communication Foundation.  
FOUNDATION™ is a trademark of the Fieldbus Foundation.  
Honeywell Process Solutions  
Industrial Measurement and Control  
Honeywell International Inc.  
2500 W. Union Hill Drive  
Phoenix, Arizona 85027  
©Honeywell International Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Swimming Pool Vacuum 1095 User Manual
Grundig Marine Radio WR 5405 User Manual
Haier Air Conditioner HW 18L2H User Manual
Hamilton Beach Coffeemaker 47334C User Manual
HANNspree Flat Panel Television ST43 15C1 User Manual
Harbor Freight Tools Ventilation Hood 94519 User Manual
HP Hewlett Packard Computer Monitor 2011S User Manual
Hubbell Work Light TMR Series User Manual
Ide Line Vacuum Cleaner 740 108 User Manual
iHome Laptop Docking Station iB970 User Manual