Honeywell Satellite Radio STR12D User Manual

34-ST-03-64  
2/08  
ST 3000 Smart Transmitter  
Series 100 Remote Diaphragm Seals Models  
Specification and  
Model Selection  
Guide  
STR12D  
STR13D  
STR14G  
STR17G  
STR14A  
0-10 to 0-400 inH O  
0-5 to 0-100 psid  
0-5 to 0-500 psig  
0-100 to 0-3000 psig 0-7 to 0-210 bar  
0-5 to 0-500 psia 0-0.35 to 0-35 bar  
0-25 to 0-1000 mbar  
0-0.35 to 0-7 bar  
0-0.35 to 0-35 bar  
2
Introduction  
In 1983, Honeywell introduced the first  
Smart Pressure Transmitterthe ST  
3000®. In 1989, Honeywell launched  
the first all digital, bi-directional protocol  
for smart field devices. Today, its ST  
3000 Series 100 Remote Seal  
Transmitters continue to bring proven  
“smart” technology to a wide spectrum  
of measurement applications. Typical  
applications include high accuracy level  
measurement in pressurized vessels in  
the chemical and hydrocarbon  
processing industries. A second  
application consists of accurate flow  
measurement for slurries and high  
viscosity fluids in the chemical industry.  
Honeywell remote seal transmitters  
demonstrate proven reliability in  
hundreds on installations in a wide  
variety of industries and applications  
with a wide variety of secondary fill  
fluids for corrosive or high temperature  
process fluids.  
All ST 3000 transmitters can provide a  
4-20 mA output, Honeywell Digitally  
Enhanced (DE) output, HART* output,  
or FOUNDATION™ Fieldbus output.  
When digitally integrated with  
Figure 1—Series 100 Remote Seal Pressure Transmitters feature proven  
piezoresistive sensors and advanced seal technology with standard weld  
connections.  
Honeywell’s Process Knowledge  
System™, EXPERION PKS™,  
ST 3000 instruments provide a more  
accurate process variable as well as  
advanced diagnostics.  
The devices provide comprehensive self-diagnostics to help users  
maintain high uptime, meet regulatory requirements, and attain high  
quality standards. S100 transmitters are ideal for critical applications,  
such as custody transfer of natural gas and energy and material  
balances, where accuracy and stability are of the utmost importance.  
Honeywell’s high-performance ST 3000  
S100 transmitters lead the industry in:  
"Our commitment to Honeywell field instruments is based on  
seamless integration with our Honeywell system and the enhanced  
fault detection that the Honeywell DE protocol offers. Honeywell  
instruments also offer us a better way of ensuring database integrity  
over simple analog instruments. In addition, Honeywell's high-quality  
support has enabled us to better implement solutions to some of our  
more difficult problems. We have used Honeywell differential pressure  
smart transmitters for the past eight years. Based on their accuracy  
and low failure rates, we are now targeting critical flow applications  
that require the robustness that these transmitters bring.”  
DCS Systems Engineer  
Accuracy  
Stability  
Reliability  
Rangeability  
Warranty  
Includes LifetimeTransmitters:  
Total Accuracy = ±0.0375%  
Stability = ±0.01% per year  
Reliability = 470 years MTBF  
Rangeability = 400 to 1  
International Integrated Oil Company  
Lifetime Warranty = 15 years  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 3  
Description of Diaphragm Seals  
Figure 6 - Seals with Threaded Process  
Connections can be used with differential, gauge and  
absolute pressure transmitters and are available with  
½”, ¾” and 1” NPT Female process connections.  
Figure 6  
Figure 7 - Sanitary Seals can be used with  
differential, gauge and absolute pressure transmitters  
and are available with 3” and 4” Tri-Clover-Tri-Clamp  
process connections.  
Figure 7  
Figure 8  
Figure 9  
Figure 10  
Figure 8 - Saddle Seals can be used with differential,  
gauge and absolute pressure transmitters and are  
available with 3” and 4” (6 bolt or 8 bolt designs)  
process connections.  
Figure 9 - Calibration Rings are available with Flush  
Flange Seals and Pancake Seals. Flushing ports (1/4”  
or ½”) are available with calibration rings.  
Figure 10 - Stainless Steel Armor and PVC Coated  
Stainless Steel Armor Capillaries are available with  
Honeywell Remote Seal Solutions.  
Figure 11 - 2” Stainless Steel Nipples are available  
for Close-Coupled remote seal solutions.  
Figure 11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 4  
Figure 12 - Welded Meter Body for All-Welded  
Remote Seal Solution. The welded ST 3000 meter  
body is an important part of an All-Welded Remote  
Seal Solution, which is commonly used in Vacuum  
applications.  
Figure 12  
Description  
Features  
Choice of linear or square root  
output conformity is a simple  
configuration selection.  
The ST 3000 transmitter can replace any 4 to 20 mA output  
transmitter in use today and operates over a standard two-wire  
system.  
Direct digital integration with  
Experion PKS and other control  
systems provides local  
measurement accuracy to the  
system level without adding  
typical A/D and D/A converter  
inaccuracies.  
The measuring means is a piezoresistive sensor, which actually  
contains three sensors in one. It contains a differential pressure  
sensor, a temperature sensor, and a static pressure sensor.  
Microprocessor-based electronics provide higher span-turndown  
ratio, improved temperature and pressure compensation, and  
improved accuracy.  
Unique piezoresistive sensor  
automatically compensates input  
for temperature and static  
pressure. Added “smart”  
features include configuring  
lower and upper range values,  
simulating accurate analog  
output, and selecting  
The transmitter’s meter body and electronics housing resist shock,  
vibration, corrosion, and moisture. The electronics housing contains  
a compartment for the single-board electronics, which is isolated  
from an integral junction box. The single-board electronics is  
replaceable and interchangeable with any other ST 3000 Series 100  
or Series 900 model transmitter.  
preprogrammed engineering  
units for display.  
Like other Honeywell transmitters, the ST 3000 features two-way  
communication and configuration capability between the operator  
and the transmitter through several Honeywell field-rated portable  
configuration devices, including the Smart Field Communicator  
(SFC) and the Multiple Communication Configurator (MC ToolKit).  
While both are made for in-field use, the MC Toolkit also can be  
ordered for use in intrinsically safe environments.  
Smart transmitter capabilities  
with local or remote interfacing  
means significant manpower  
efficiency improvements in  
commissioning, start-up, and  
ongoing maintenance functions.  
The SCT 3000 Smartline® Configuration Toolkit provides an easy  
way to configure instruments using a personal computer. The toolkit  
enables configuration of devices before shipping or installation. The  
SCT 3000 can operate in the offline mode to configure an unlimited  
number of devices. The database can then be loaded down-line  
during commissioning.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 5  
Specifications  
Operating Conditions – All Models  
Parameter  
Reference Condition  
Rated Condition  
Operative Limits  
Transportation and  
Storage  
°C  
°F  
°C  
°F  
°C  
°F  
°C  
°F  
Ambient Temperature *  
25 ±1  
77 ±2  
–55 to 90 –67 to 194  
0 to 100  
Humidity  
% RH  
10 to 55  
0 to 100  
0 to 100  
Maximum Allowable  
MAWP is minimum of Body Rating or Seal Rating (See Model Selection Guide for Seal  
Working Pressure (MAWP) MAWP)  
Body  
MAWP  
STR12D  
STR13D  
STR12D  
STR13D  
STR14G  
STR17G  
STR14A  
2500 psig (172 bar) Bolted Process Heads Table I _ _ A  
2500 psig (172 bar) Bolted Process Heads Table I _ _ A  
1450 psig (100 bar) All Welded Process Heads Table I _ _ C  
1450 psig (100 bar) All Welded Process Heads Table I _ _ C  
500 psig (35 bar)  
3000psig (207 bar)  
500 psia (35 bar).  
Vacuum Region - Minimum  
Pressure  
mmHg absolute  
Atmospheric (See Figure 15 for vacuum limitations.)  
Supply Voltage, Current,  
and Load Resistance  
Voltage Range:  
Current Range:  
Load Resistance:  
10.8 to 42.4 Vdc at terminals  
3.0 to 21.8 mA  
0 to 1440 ohms (as shown in Figure 16)  
* Ambient Temperature Limit is a function of Process Interface Temperature. (See Figure 13.)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 6  
Performance Under Rated Conditions * - Model STR12D (0-10 to 0-400 inH O)  
2
Parameter  
Description  
Upper Range Limit **  
inH2O 400 (39.2°F/4°C is standard reference temperature for inH O range.)  
2
mbar  
1000  
Minimum Span  
Turndown Ratio  
inH2O 10 Note: Recommended minimum span in square root mode is 20 inH O (50 mbar).  
2
mbar  
25  
40 to 1  
Zero Elevation and Suppression No limit except minimum span within ±100% URL.  
Accuracy (Reference – Includes  
combined effects of linearity,  
hysteresis, and repeatability)  
In Analog Mode: ±0.2% of calibrated span or upper range value (URV), whichever is  
greater, terminal based.  
For URV below reference point (50 inH O), accuracy equals:  
2
Accuracy includes residual error  
after averaging successive  
readings.  
50 inH O  
2
125 mbar  
span mbar  
±0.1 + 0.1  
or ±0.1 + 0.1  
in % of span  
(
)
span inH O  
2
In Digital Mode: ±0.175% of calibrated span or upper range value (URV), whichever is  
greater, terminal based.  
For FOUNDATION Fieldbus use  
Digital Mode specifications. For  
HART use Analog Mode  
specifications.  
For URV below reference point (50 inH O), accuracy equals:  
2
50 inH O  
span inH O  
2
125 mbar  
span mbar  
±0.075 + 0.10  
or ±0.075 + 0.10  
in % of span  
(
)
2
Combined Zero and Span  
Temperature Effect per 28°C  
(50°F) ***  
In Analog Mode: ±1.2% of span.  
For URV below reference point (200 inH O), effect equals:  
2
200 in H2O  
500 mbar  
±0.2 + 1.0  
or ±0.2 + 1.0  
In % span  
span in H2O  
span mbar  
In Digital Mode: ±1.175% of span.  
For URV below reference point (200 inH O), effect equals:  
2
200 in H2O  
500 mbar  
In % span  
or ±0.175 + 1.0  
±0.175 + 1.0  
span in H2O  
span mbar  
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and  
316L Stainless Steel barrier diaphragm.  
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.  
*** Specification applies to transmitters with 2 seals only. Apply 1.5 times factor to temperature effect for capillary lengths greater than 10  
feet.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 7  
Performance Under Rated Conditions * - Model STR13D (0-5 to 0-100 psid)  
Parameter  
Description  
Upper Range Limit **  
psid 100  
bar  
7
Minimum Span  
Turndown Ratio  
psid  
bar 0.35  
5
20 to 1  
Zero Elevation and Suppression No limit except minimum span within –18% and +100% of URL. Specifications valid from  
–5% to 100% of URL.  
Accuracy (Reference – Includes  
combined effects of linearity,  
hysteresis, and repeatability)  
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is  
greater, terminal based.  
For URV below reference point (30 psi), accuracy equals:  
Stated accuracy does not apply  
for models with 2.9 inch  
diameter remote seal  
diaphragms.  
30 psi  
(span psi)  
2 bar  
(span bar)  
±0.05 + 0.05  
or ±0.05 + 0.05  
in % of span  
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is  
greater, terminal based.  
Accuracy includes residual error  
after averaging successive  
readings.  
For URV below reference point (30 psi), accuracy equals:  
30 psi  
(span psi)  
2 bar  
(span bar)  
±0.025 + 0.05  
or ±0.025 + 0.05  
in % of span  
For FOUNDATION Fieldbus use  
Digital Mode specifications. For  
HART use Analog Mode  
specifications.  
Combined Zero and Span  
Temperature Effect per 28°C  
(50°F) ***  
In Analog Mode: ±0.33% of span.  
For URV below reference point (60 psi), effect equals:  
60 psi  
4 bar  
or ±0.05 + 0.28  
In % span  
±0.05 + 0.2  
span psi  
span bar  
In Digital Mode: ±0.305% of span.  
For URV below reference point (60 psi), effect equals:  
60 psi  
4 bar  
or ±0.025 + 0.28  
In % span  
±0.025 + 0.25  
span psi  
span bar  
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and  
316L Stainless Steel barrier diaphragm.  
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.  
*** Specification applies to transmitters with 2 seals only. Apply 1.5 times factor to temperature effect for capillary lengths greater than 10  
feet.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 8  
Performance Under Rated Conditions * - Model STR14G (0-5 to 0-500 psig)  
Parameter  
Description  
Upper Range Limit **  
psig 500  
bar 35  
Minimum Span  
Turndown Ratio  
psig  
bar 0.35  
5
100 to 1  
Zero Elevation and Suppression No limit except minimum span from absolute zero to 100% of URL. Specifications valid  
over this range.  
Accuracy (Reference – Includes  
combined effects of linearity,  
hysteresis, and repeatability)  
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is  
greater.  
For URV below reference point (20 psi), accuracy equals:  
Accuracy includes residual error  
after averaging successive  
readings.  
20 psi  
(span psi)  
1.4 bar  
(span bar)  
±0.05 + 0.05  
or ±0.05 + 0.05  
in % of span  
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is  
For FOUNDATION Fieldbus use  
Digital Mode specifications. For  
HART use Analog Mode  
specifications.  
greater.  
For URV below reference point (20 psi), accuracy equals:  
20 psi  
(span psi)  
1.4 bar  
(span bar)  
±0.025 + 0.05  
or ±0.025 + 0.05  
in % of span  
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and  
316L Stainless Steel barrier diaphragm.  
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 9  
Performance Under Rated Conditions * - Model STR17G (0-100 to 0-3000 psig)  
Parameter  
Description  
Upper Range Limit **  
psig 3000  
bar 210  
Minimum Span  
Turndown Ratio  
psig 100  
bar  
7
30 to 1  
Zero Elevation and Suppression No limit except minimum span from absolute zero to 100% of URL. Specifications valid  
over this range.  
Accuracy (Reference – Includes  
combined effects of linearity,  
hysteresis, and repeatability)  
In Analog Mode: ±0.15% of calibrated span or upper range value (URV), whichever is  
greater.  
For URV below reference point (300 psi), accuracy equals:  
Accuracy includes residual error  
after averaging successive  
readings.  
300 psi  
(span psi)  
21 bar  
(span bar)  
±0.10 + 0.05  
or ±0.10 + 0.05  
in % of span  
In Digital Mode: ±0.125% of calibrated span or upper range value (URV), whichever is  
For FOUNDATION Fieldbus use  
Digital Mode specifications. For  
HART use Analog Mode  
specifications.  
greater.  
For URV below reference point (300 psi), accuracy equals:  
300 psi  
(span psi)  
21 bar  
(span bar)  
±0.075 + 0.05  
or ±0.075 + 0.05  
in % of span  
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and  
316L Stainless Steel barrier diaphragm.  
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 10  
Performance Under Rated Conditions * - Model STR14A (0-5 to 0-500 psia)  
Parameter  
Description  
Upper Range Limit **  
psia 500  
bar absolute 35  
Minimum Span  
Turndown Ratio  
psia  
5
bar absolute 0.35  
100 to 1  
Zero Elevation and Suppression No limit except minimum span from 0 to 100% URL.  
Accuracy (Reference – Includes  
combined effects of linearity,  
hysteresis, and repeatability)  
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is  
greater.  
For URV below reference point (20 psi), accuracy equals:  
Accuracy includes residual error  
after averaging successive  
readings.  
20 psi  
(span psi)  
1.4 bar  
(span bar)  
±0.05 + 0.05  
or ±0.05 + 0.05  
in % of span  
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is  
For FOUNDATION Fieldbus use  
Digital Mode specifications. For  
HART use Analog Mode  
specifications.  
greater.  
For URV below reference point (20 psi), accuracy equals:  
20 psi  
(span psi)  
1.4 bar  
(span bar)  
±0.025 + 0.05  
or ±0.025 + 0.05  
in % of span  
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and  
316L Stainless Steel barrier diaphragm.  
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.  
Performance Under Rated Conditions – General for all Models  
Parameter  
Description  
Output (two-wire)  
Analog 4 to 20 mA or digital communications DE mode. Options available for  
FOUNDATION Fieldbus and HART protocol.  
Supply Voltage Effect  
±0.005% of span per volt.  
Damping Time Constant  
RFI Protection (Standard)  
CE Conformity (Europe)  
Adjustable from 0 to 32 seconds digital damping.  
Negligible (20 to 1000 MHz at 30 volts per meter).  
89/336/EEC, Electromagnetic Compatibility (EMC) Directive.  
NAMUR NE 43 Compliance  
Option  
Transmitter failure information is generated when the measuring information is invalid or  
no longer present. Failure information is transmitted as a current signal but outside the  
normal 4-20 mA measurement signal level. Transmitter failure values are: 3.6 mA and  
21.0 mA. The normal signal range is 3.8 mA and 20.5 mA.  
SIL 2/3 Compliance  
SIL certified to IEC 61508 for non-redundant use in SIL 2 related Safety Systems  
(single use) and for redundant (multiple) use in SIL 3 Safety Systems through  
TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 1998;  
IEC 61508-2: 2000; IEC61508-3: 1998.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 11  
Physical and Approval Bodies  
Parameter  
Description  
Process Interface  
See Model Selection Guide for Material Options for desired seal type.  
316L Stainless Steel, Monel, Hastelloy C, Tantalum  
Seal Barrier Diaphragm  
Seal Gasket Materials  
Mounting Bracket  
Klinger C-4401 (non-asbestos)  
Grafoil  
Teflon  
Gylon 3510  
Carbon Steel (Zinc-Chromate plated) or Stainless Steel.  
Fill Fluid (Meter Body)  
Silicone (DC 200)  
CTFE (Chlorotrifluoroethylene)  
S.G. @ 25°C = 0.94  
S.G. @ 25°C = 1.89  
Fill Fluid (Secondary)  
Silicone (DC 200)  
CTFE (Chlorotrifluoroethylene)  
Silicone (DC 704)  
NEOBEE M-20  
S.G. @ 25°C = 0.94  
S.G. @ 25°C = 1.89  
S.G. @ 25°C = 1.07  
S.G. @ 25°C = 0.90  
S.G. @ 25°C = 0.93  
Syltherm 800  
Electronic Housing  
Capillary Tubing  
Epoxy-Polyester hybrid paint. Low copper-aluminum alloy. Meets NEMA 4X (watertight)  
and NEMA 7 (explosion proof). Stainless steel optional.  
Armored Stainless Steel or PVC Coated Armored Stainless Steel.  
Length: 5, 10, 15, 20, 25, and 35 feet (1.5, 3, 4.6, 6.1, 7.5, and 10.7 meters).  
A 2 inch (51 millimeter) S.S. close-coupled nipple is also available. See Model Selection  
Guide. Refer to Figure 14 for guide to maximum capillary length vs. diaphragm diameter.  
Wiring  
Accepts up to 16 AWG (1.5 mm diameter).  
See Figure 17.  
Mounting  
Dimensions  
Net Weight  
Transmitter: See Figures 20a and 20b. Seal: See Figures 21 through 31.  
Transmitter: 15.4 pounds (7 Kg). Total weight is dependent on seal type and capillary  
length.  
Approval Bodies  
Factory Mutual  
Explosion Proof: Approved as Explosion Proof for Class I, Division 1, Groups A, B,  
C, D locations,  
Dust Ignition Proof: Approved as Dust Ignition Proof for Class II, III, Division 1,  
Groups E, F, G locations,  
Intrincically Safe: Approved as Intrinsically Safe for for Class I, II, III, Division 1,  
Groups A, B, C, D, E, F, G locations.  
Nonincendive: Approved as Nonincendive for Class I, Division 2, Groups A, B, C, D  
locations.  
Explosion Proof: Approved as Explosion Proof for Class I, Division 1, Groups B, C,  
D locations,  
Dust Ignition Proof: Approved as Dust Ignition Proof for Class II, III, Division 1,  
Groups E, F, G locations,  
CSA  
Intrincically Safe: Approved as Intrinsically Safe for Class I, II, III, Division 1, Groups  
A, B, C, D, E, F, G locations.  
Canadian Registration  
Number (CRN)  
All ST 3000 model designs, except SATG19L, STG99L, STG170 and STG180 have  
been registered in all provinces and territories in Canada and are marked  
CRN:0F8914.5c.  
Intrinsically Safe, Zone 0/1: EEx ia IIC T4, T5, T6  
Flameproof/Zone 1:  
Non-Sparking, Zone 2:  
Multiple Markings:  
EEx d IIC T5, T6 (enclosure IP 66/67)  
EEx nA, IIC T6 (enclosure IP 66/67)  
Ex II 1 G: EEx ia IIC T4, T5, T6, Ex II 2 G: EExd IIC T5, T6  
Ex II 3 G: EEx nA, IIC T6 (Honeywell) (enclosure IP 66/67)  
ATEX  
Intrinsically Safe: EX ia IIC T4  
Non-Sparking: Ex n IIC T6 (T4 with SM option)  
SA (Australian)  
INMETRO (Brazil)  
Flame-Proof, Zone 1: EX d IIC T5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 12  
Parameter  
Description  
Pressure Equipment Directive  
(97/23/EC)  
The ST 3000 pressure transmitters listed in this Specification have no pressurized  
internal volume or have a pressurized internal volume rated less than 1,000 bar (14,500  
psig) and/or have a maximum volume of less than 0.1 liter. Therefore, these  
transmitters are either; not subject to the essential requirements of the directive  
97/23/EC (PED, Annex 1) and shall not have the CE mark, or the manufacturer has the  
free choice of a module when the CE mark is required for pressures > 200 bar (2,900  
psig).  
NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems) or vessel(s) from  
exceeding allowable pressure limits, (equipment with safety functions in accordance with Pressure Equipment Directive  
97/23/EC article 1, 2.1.3), require separate examination.  
200  
185  
165  
180  
160  
140  
120  
100  
80  
140  
Maximum Ambient  
Temperature (°F)  
60  
40  
20  
0
200  
Process Interface Temperature (°F)  
350  
450  
Figure 13—Ambient temperature and process interface chart.  
Transmitter Minimum Span and Maximum Capillary Length  
Minimum recommended span for STR12D and STR13D DP Transmitter with two Remote Seals  
Diaphragm  
Capillary  
10'  
-
125 iwc  
20 iwc  
15 iwc  
Capillary Length  
Size  
2.4  
2.9  
3.5  
4.1  
5'  
15'  
-
150 iwc  
24 iwc  
18 iwc  
20'  
-
175 iwc  
28 iwc  
21 iwc  
30'  
-
-
36 iwc  
27 iwc  
35'  
-
-
40 iwc  
30 iwc  
maximum  
200 iwc  
100 iwc  
16 iwc  
12 iwc  
5'  
20'  
35'  
35'  
Minimum recommended span for STR12D and STR13D DP Transmitter with one Remote Seal  
Diaphragm  
Direct  
Mount  
20 psig  
10 psig  
50 iwc  
40 iwc  
Capillary  
10'  
-
20 psig  
100 iwc  
80 iwc  
Capillary Length  
Size  
2.4  
2.9  
3.5  
4.1  
5'  
15'  
-
25 psig  
120 iwc  
100 iwc  
20'  
-
30 psig  
140 iwc  
120 iwc  
30'  
-
-
180 iwc  
160 iwc  
35'  
-
-
200 iwc  
180 iwc  
maximum  
30 psig  
15 psig  
80 iwc  
60 iwc  
5'  
20'  
35'  
35'  
Minimum recommended span for STR14G, STR14A, STR17G Transmitter with Remote Seal  
Diaphragm  
Direct  
Mount  
25 psi  
10 psi  
8 psi  
Capillary  
10'  
40 psi  
20 psi  
10 psi  
5 psi  
Capillary Length  
Size  
2.0  
2.4  
2.9  
3.5  
4.1  
5'  
15'  
20'  
-
30 psi  
12 psi  
5 psi  
5 psi  
30'  
-
40 psi  
14 psi  
7 psi  
7 psi  
35'  
-
50 psi  
15 psi  
8 psi  
8 psi  
maximum  
30 psi  
15 psi  
9 psi  
5 psi  
5 psi  
50 psi  
25 psi  
11 psi  
5 psi  
15'  
35'  
35'  
35'  
35'  
5 psi  
5 psi  
5 psi  
5 psi  
Minimum span is the higher of the value from the table above or the value defined under Performance Conditions for the range transmitter  
Figure 14—Maximum capillary length and diaphragm size chart.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 13  
Figure 15—ST 3000 Remote Seals operable limits for pressure vs. temperature.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 14  
1440  
1200  
Note: A minimum of 250 ohms  
of loop resistance is necessary  
to support communications.  
Loop resistance equals barrier  
resistance plus wire resistance  
plus receiver resistance.  
Loop  
Resistance  
(ohms)  
800  
650  
450  
250  
= Operating Area  
0
10.8  
16.28 20.63 25 28.3 37.0  
42.4  
Operating Voltage (Vdc)  
Figure 16—Supply voltage/loop resistance chart.  
LP Side  
Maximum level  
H2  
Fixed  
ref. leg  
Variable  
Head  
H1  
Minimum level  
.
24249  
HP Side  
NOTE: Lower flange seal should not be mounted over 22 feet below or above  
the transmitter for silicone fill fluid (11 feet for CTFE fill fluid) with tank at one  
atmosphere. The combination of tank vacuum and high pressure capillary  
head effect should not exceed 9 psi vacuum (300 mmHg absolute).  
Consult Honeywell for installation of STR13D.  
Figure 17—The ST 3000 transmitter with remote diaphragm seals shown mounted on a tank.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 15  
Application Data*  
Max  
Level  
LP  
Liquid Level: Closed Tank  
Determine the minimum and  
maximum pressure differentials to  
be measured (Figure 18).  
b
P
Min  
= (SG x a) – (SG x d)  
p
f
Min  
Level  
= LRV when HP at bottom  
of tank  
HP  
a
= –URV when LP at  
bottom of tank  
Transmitter above datum  
P
Max  
= (SG x b) – (SG x d)  
p
f
= URV when HP at bottom  
of tank  
Max  
Level  
LP  
= –LRV when LP at bottom  
of tank  
Where:  
Minimum level at 4 mA  
b
Maximum level at 20 mA  
Min  
Level  
HP  
a
a = distance between bottom  
tap and minimum level  
Transmitter at datum  
b = distance between bottom  
tap and maximum level  
d = distance between taps  
Max  
LP  
Level  
SG = Specific Gravity of capillary  
f
fill fluid (see page 11 for  
values)  
SG = Specific Gravity of  
p
b
process fluid  
Min  
HP  
Level  
a
Transmitter below datum  
24253  
Figure 18—Closed tank liquid level measurement distances.  
* Contact STC-Phoenix concerning  
applications for model STR13D.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 16  
Density or Interface*  
Calculate the minimum and  
maximum pressure differentials to  
be measured.  
P
min  
= (SG  
- SG ) x (d);  
min  
LP  
f
minimum density, 4mA  
output  
P
max  
= (SG  
- SG ) x (d);  
max  
f
maximum density, 20mA  
output  
Where:  
HP  
d = distance between the  
taps  
24257  
SG  
= maximum Specific  
Gravity  
max  
SG  
= minimum Specific  
Gravity  
min  
SGf = Specific Gravity of  
capillary fill fluid (see  
page 11 for values)  
Figure 19—Density, direct acting instrument configuration.  
* Contact STC-Phoenix concerning  
applications for model STR13D.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 17  
82.9  
3.26  
94.9  
3.74  
65.1  
2.56  
With Smart meter  
With Analog  
meter  
53.1  
3.6  
135  
5.32  
Reference  
Dimensions:  
millimeters  
inches  
Removal 45.7  
Clearance 1.8  
for All Caps  
2.09  
0.14  
Plug  
Without Without  
meter  
meter  
55.3  
2.18  
Optional  
meters  
23.5  
.925  
Rotational  
lock  
Optional external  
ground  
STR12D, STR13D  
DP/I Remote Seal  
with Horizontal  
Pipe Mount  
LP seal  
omitted for  
clarity  
85  
3.35  
42.5  
1.67  
50  
1.97  
82.9  
3.26  
94.9  
3.74  
With Smart meter  
With Analog meter  
53.1  
2.09  
65.1  
2.56  
3.6  
0.14  
Removal  
45.7  
135  
Plug  
Clearance  
Without Without  
5.32  
1.8  
meter  
meter  
for All Caps  
55.3  
2.18  
Optional  
meters  
STR14A  
23.5  
.925  
AP/I Remote Seal  
with Horizontal  
Pipe Mount  
Rotational  
lock  
Optional external  
ground  
Seal  
omitted  
for clarity  
71.1  
2.80  
SQ.  
82.9  
3.26  
94.9  
3.74  
With Smart meter  
With Analog meter  
53.1  
65.1  
2.56  
Removal 45.7  
Clearance 1.8  
for All Caps  
2.09  
135  
5.32  
3.6  
0.14  
Plug  
Without Without  
meter  
meter  
55.3  
2.18  
STR14G, STR17G  
Optional  
meters  
LGP/I Remote Seal  
with Horizontal  
Pipe Mount  
23.5  
.925  
Rotational  
lock  
Optional external  
ground  
Seal  
omitted  
for clarity  
24261  
Figure 20a —Approximate horizontal mounting dimensions for Remote Seal Transmitter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 18  
82.9  
3.26  
94.9  
3.74  
65.1  
2.56  
With Smart meter  
With Analog  
meter  
53.1  
Reference  
Dimensions:  
millimeters  
inches  
3.6  
135  
5.32  
Removal 45.7  
Clearance 1.8  
for All Caps  
2.09  
0.14  
Plug  
Without Without  
meter  
meter  
55.3  
2.18  
Optional  
meters  
23.5  
.925  
LP seal  
omitted  
for clarity  
Rotational  
lock  
Optional external  
ground  
STR12D, STR13D  
DP/I Remote Seal  
with Vertical  
85  
3.35  
SQ  
Pipe Mount  
50  
1.97  
42.5  
1.67  
82.9  
3.26  
94.9  
3.74  
65.1  
2.56  
With Smart meter  
With Analog  
meter  
53.1  
Removal  
3.6  
0.14  
45.7  
1.8  
2.09  
135  
5.32  
Plug  
Clearance  
for All Caps  
Without Without  
STR14A  
meter  
meter  
AP/I Remote Seal  
with Vertical  
Pipe Mount  
55.3  
2.18  
Optional  
meters  
23.5  
.925  
Rotational  
lock  
Optional external  
ground  
Seal  
omitted  
for clarity  
71.1  
2.80  
SQ.  
82.9  
3.26  
94.9  
3.74  
65.1  
2.56  
With Smart meter  
With Analog  
meter  
53.1  
Removal 45.7  
Clearance 1.8  
for All Caps  
2.09  
135  
5.32  
3.6  
0.14  
Plug  
Without Without  
STR14G, STR17G  
LGP/I Remote Seal  
with Vertical Pipe  
Mount (Flat Bracket)  
meter  
meter  
55.3  
2.18  
23.5  
.925  
Optional  
meters  
Rotational  
lock  
Optional external  
ground  
Seal  
omitted  
for clarity  
24262  
Figure 20b —Approximate vertical mounting dimensions for Remote Seal Transmitter.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 19  
Options  
NAMUR NE43 Compliance  
Ordering Information  
Mounting Bracket  
Contact your nearest Honeywell sales  
office, or  
The angle mounting bracket is  
available in either zinc-plated  
carbon steel or stainless steel and  
is suitable for horizontal or vertical  
mounting on a two inch (50  
millimeter) pipe, as well as wall  
mounting. An optional flat  
mounting bracket is also available  
in carbon steel for two inch (50  
millimeter) pipe mounting.  
(Option NE)  
This option provides software the  
meets the NAMUR NE43  
In the U.S.:  
requirements for failsafe software.  
Transmitter failure information is  
generated when the measuring  
information is no longer valid.  
Transmitter failure values are:  
3.6 mA and 21.0 mA. The  
normal ST 3000 ranges are 3.8  
mA and 20.5 mA.  
Honeywell  
Industrial Automation & Control  
16404 North Black Canyon Hwy.  
Phoenix, AZ 85053  
1-800-288-7491  
In Canada:  
The Honeywell Centre  
155 Gordon Baker Rd.  
North York, Ontario M2H 3N7  
1-800-461-0013  
Indicating Meter  
(Options ME and SM)  
Lightning Protection  
(Option LP)  
Two integral meter options are  
available. An analog meter (option  
ME) is available with a 0 to 100%  
linear scale. The Smart Meter  
(option SM) provides an LCD  
display for both analog and digital  
output and can be configured to  
display pressure in pre-selected  
engineering units.  
A terminal block with circuitry that  
protects the transmitter from  
transient surges induced by  
nearby lightning strikes is  
available.  
In Latin America:  
Honeywell Inc.  
480 Sawgrass Corporate Parkway,  
Suite 200  
Sunrise, FL 33325  
(954) 845-2600  
Indicator Configuration  
(Option CI)  
Provides custom configuration of  
Smart Meters  
In Europe and Africa:  
Honeywell S. A.  
HART® Protocol Compatibility  
(Options HC and H6)  
Optional electronics modules for  
the ST 3000 provides HART  
Protocol compatibility in either  
HART 5.x or 6.x formats.  
Avenue du Bourget 1  
1140 Brussels, Belgium  
Tagging (Option TG)  
Up to 30 characters can be added  
on the stainless steel nameplate  
mounted on the transmitter’s  
electronics housing at no extra  
cost. Note that a separate  
nameplate on the meter body  
contains the serial number and  
body-related data. A stainless  
steel wired on tag with additional  
data of up to 4 lines of 28  
In Eastern Europe:  
Honeywell Praha,  
s.r.o. Budejovicka 1  
140 21 Prague 4,  
Czech Republic  
Transmitters with a HART Option  
are compatible with any HART  
enabled system that provides 5.x  
or 6.x format support.  
In the Middle East:  
Honeywell Middle East Ltd.  
Khalifa Street,  
FOUNDATION Fieldbus  
(Option FF)  
Sheikh Faisal Building  
Abu Dhabi, U. A. E.  
characters is also available. The  
number of characters for tagging  
includes spaces.  
Equips transmitter with FF  
protocol for use in 31.25 kbit/s FF  
networks. See document 34-ST-  
03-72 for additional information on  
ST 3000 Fieldbus transmitters.  
In Asia:  
Honeywell Asia Pacific Inc.  
Transmitter Configuration  
(Option TC)  
Honeywell Building,  
17 Changi Business Park Central 1  
Singapore 486073  
The factory can configure the  
transmitter linear/square root  
extraction, damping time, LRV,  
URV and mode (analog/digital) and  
enter an ID tag of up to eight  
characters and scratchpad  
information as specified.  
SIL2/SIL3 Certification  
(Option SL)  
Republic of Singapore  
This ST 3000 product is available  
for use with safety systems. With  
the SL option, we are fully certified  
to SIL 2 capability for single  
transmitters and SIL 3 capability for  
multiple transmitter use through  
TÜV Nord Sys Tec GmbH & Co.  
KG. We are in compliance with the  
following SIL standards:  
In the Pacific:  
Honeywell Pty Ltd.  
5 Thomas Holt Drive  
North Ryde NSW Australia 2113  
(61 2) 9353 7000  
Custom Calibration and ID in  
Memory (Option CC)  
In Japan:  
The factory can calibrate any range  
within the scope of the transmitter’s  
range and enter an ID tag of up to  
eight characters in the transmitter’s  
memory.  
Honeywell K.K.  
14-6 Shibaura 1-chrome  
Minato-ku, Tokyo, Japan 105-0023  
IEC 61508-1: 1998;  
IEC 61508-2: 2000;  
IEC 61508-3: 1998  
Or, visit Honeywell on the World Wide  
Specifications are subject to change  
without notice  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 20  
Model Selection Guide (34-ST-16-32)  
Model Selection Guide  
34-ST-16-32 Issue 39  
Instructions  
Select the desired Key Number. The arrow to the right marks the selection available.  
Make one selection from each Table I and II using the column below the proper arrow.  
Select as many Table III options as desired (if no options or approvals are desired, specify 9X).  
A () denotes unrestricted availability. A letter denotes restricted availability.  
Restrictions follow Table IV.  
I
II  
III (Optional)  
IV  
Key Number  
_ _ _ _ _ _  
_ _ _  
_ _ _ _ _ _ _ _ _ _ _ _  
_ _ , _ _  
XXXX  
-
-
-
+
KEY NUMBER  
Availability  
Description  
Selection  
0-10" to 0-400" H2O/0-25 to 0-1,000 mbar  
Body Rating*: 2,500 psi (172 bar) Compound Characterized  
0-5 to 0-100 psi/0-0.34 to 0-7 bar  
STR12D  
STR13D  
STR14A  
STR14G  
STR17G  
Body Rating*: 2,500 psi (172 bar)  
0-5 to 0-500 psia/0-0.34 to 0-35 bar  
Body Rating*: 500 psi (35 bar)  
0-5 to 0-500 psi/0-0.34 bar to 0-35 bar  
Body Rating*: 500 psi (35 bar)  
0-100 to 0-3,000 psi/0-7 bar to 210 bar  
Body Rating*: 3,000 psi (210 bar)  
* Remote seal system pressure rating is body rating or seal rating, whichever is less.  
Base STR models no longer include a default communications option. All units now require the  
selection of a communication option from Table III (AN, DE, HC, H6 or FF).  
Important Note:  
TABLE I - METER BODY  
Selection  
1 Remote Seal (High Side)  
2 Remote Seals  
1 Remote Seal (Low Side)  
Value Added Model (VAM unit)  
Silicone (DC 200)  
1 _ _  
2 _ _  
3 _ _  
5 _ _  
_ 1 _  
_ 2 _  
8
q
Number of Seals  
8
q
8
q
Fill Fluid  
(Meter body)  
Construction  
CTFE  
Non-Wetted Adapter Head Material  
316 SS Bonnet  
_ _ A  
_ _ D  
_ _ A  
_ _ D  
_ _ C  
_ _ A  
_ _ D  
y
In-Line Gauge  
316 SS Bonnet for Close-Couple  
316 SS (bolt-on heads)  
316 SS for Close-Couple  
316 SS with all-welded meter body  
316 SS Adapter Head  
y
7
Dual Head DP  
Single Head  
Absolute  
y
316 SS Head for Close-Couple  
Dual Head DP  
In-Line Gauge  
All welded  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 21  
TABLE II - SEALS  
Format for Seal Selection:  
Specify 12 characters  
14A  
_ _ _ _ _ _ _ _ _ _ _ _  
Common Required Seal  
12D & 13D  
Selection  
14G&17G  
Note: The first 3 characters are common to all seals.  
When selecting required seal, you must specify  
only the 9 selections within the required seal.  
No Fill Fluid  
0 _ _ _ _ _ _ _ _ _ _ _  
1 _ _ _ _ _ _ _ _ _ _ _  
2 _ _ _ _ _ _ _ _ _ _ _  
3 _ _ _ _ _ _ _ _ _ _ _  
4 _ _ _ _ _ _ _ _ _ _ _  
5 _ _ _ _ _ _ _ _ _ _ _  
_ 0 _ _ _ _ _ _ _ _ _ _  
_ A _ _ _ _ _ _ _ _ _ _  
_ B _ _ _ _ _ _ _ _ _ _  
_ C _ _ _ _ _ _ _ _ _ _  
_ D _ _ _ _ _ _ _ _ _ _  
_ E _ _ _ _ _ _ _ _ _ _  
_ F _ _ _ _ _ _ _ _ _ _  
_ G _ _ _ _ _ _ _ _ _ _  
_ H _ _ _ _ _ _ _ _ _ _  
_ J _ _ _ _ _ _ _ _ _ _  
_ K _ _ _ _ _ _ _ _ _ _  
_ L _ _ _ _ _ _ _ _ _ _  
_ M _ _ _ _ _ _ _ _ _ _  
_ 2 _ _ _ _ _ _ _ _ _ _  
_ _ 0 _ _ _ _ _ _ _ _ _  
_ _ _ 0 0 0 0 0 0 0 0 0  
3
3
z
3
3
z
3
3
z
Silicone (DC 200)  
CTFE  
Secondary Fill  
Silicone (DC 704)  
Neobee(M20) **  
Syltherm 800 ***  
No Capillary, No Nipple  
5 feet  
10 feet  
15 feet  
20 feet  
25 feet  
35 feet  
5 feet  
10 feet  
15 feet  
20 feet  
25 feet  
35 feet  
1.5 m  
3.0 m  
4.5 m  
6.1 m  
7.5 m  
10.7 m  
1.5 m  
3.0 m  
4.5 m  
6.1 m  
7.5 m  
10.7 m  
SS Armor  
Connection of  
Remote Seal to  
Meter Body  
Capillary  
Length  
PVC Coated SS  
Armor  
2 inch long SS nipple close-coupled  
No Selection  
3
3
3
No Seal Attached to Core Transmitter  
Flange  
Size  
Flange Pressure  
Diaphragm  
Diameter  
Selection  
Rating *  
ANSI Class 150  
ANSI Class 300  
DIN DN80-PN40  
_ _ _ AFA _ _ _ _ _ _  
_ _ _ AFC _ _ _ _ _ _  
_ _ _ AFM _ _ _ _ _ _  
Selection  
3.5"  
3"  
Diaphragm  
Upper Insert  
316 SS  
316L SS  
Hastelloy C  
Hastelloy C  
Monel  
_ _ _ _ _ _ AA _ _ _ _  
_ _ _ _ _ _ AB _ _ _ _  
_ _ _ _ _ _ AC _ _ _ _  
_ _ _ _ _ _ AE _ _ _ _  
1
9
5
5
1
9
5
5
1
9
5
5
316 SS  
Wetted Material  
Hastelloy C  
Monel  
Flush Flanged  
Seal  
Tantalum  
316 SS  
_ _ _ _ _ _ AF _ _ _ _  
_ _ _ _ _ _ _ _ 1 _ _ _  
_ _ _ _ _ _ _ _ 2 _ _ _  
_ _ _ _ _ _ _ _ _ 1 _ _  
_ _ _ _ _ _ _ _ _ 2 _ _  
_ _ _ _ _ _ _ _ _ _ A _  
_ _ _ _ _ _ _ _ _ _ B _  
_ _ _ _ _ _ _ _ _ _ C _  
CS (Nickel Plated)  
Non-Wetted Material  
(upper)  
316 SS  
Center Seal  
Side Seal  
None  
Seal-Capillary  
Connection  
Calibration Rings  
316 SS  
Hastelloy C  
Monel  
_ _ _ _ _ _ _ _ _ _ D _  
5
5
5
Table II continued next page  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 22  
STR14A  
14G & 17G  
STR12D & 13D  
Selection  
TABLE II - SEALS (continued)  
Flushing  
None  
_ _ _ _ _ _ _ _ _ _ _ 0  
_ _ _ _ _ _ _ _ _ _ _ H  
_ _ _ _ _ _ _ _ _ _ _ J  
_ _ _ _ _ _ _ _ _ _ _ M  
_ _ _ _ _ _ _ _ _ _ _ N  
_ _ _ _ _ _ _ _ _ _ _ P  
_ _ _ _ _ _ _ _ _ _ _ Q  
_ _ _ _ _ _ _ _ _ _ _ R  
_ _ _ _ _ _ _ _ _ _ _ S  
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
6
Flush Flanged  
Seal  
Connections  
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
6
6
6
6
6
6
6
6
and Plugs****  
(Metal plug material  
will be the same as  
Cal. ring material if  
metal plug is chosen -  
SS Plug for CS Lower)  
Table II continued below  
Standard facing 125-250 AARH RF (raised face) serrated surface finish.  
Limited vacuum availability.  
*
**  
Minimum static pressure requirement. No vacuum allowed. See Specifications Figure 15.  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS non-wetted parts  
***  
****  
a
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.  
STR12D & 13D  
Selection  
STR14A  
14G & 17G  
TABLE II - SEALS (continued)  
Flange  
Pressure  
Rating *  
Const. - See  
Spec. Figure 34-  
ST-03-64  
Flange  
Size  
Construction - See Spec.  
Figure 34-ST-03-64  
Diaphragm  
Diameter  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
ANSI 150  
ANSI 300  
22  
22  
22  
22  
22  
22  
22  
22  
23  
23  
23  
22  
22  
22  
22  
22  
23  
23  
23  
23  
23  
22  
22  
22  
_ _ _ BCA _ _ _ _ _ _  
_ _ _ BCC _ _ _ _ _ _  
_ _ _ BGA _ _ _ _ _ _  
_ _ _ BGC _ _ _ _ _ _  
_ _ _ BDA _ _ _ _ _ _  
_ _ _ BDC _ _ _ _ _ _  
_ _ _ BFA _ _ _ _ _ _  
_ _ _ BFC _ _ _ _ _ _  
_ _ _ CAA _ _ _ _ _ _  
_ _ _ CCA _ _ _ _ _ _  
_ _ _ CCC _ _ _ _ _ _  
_ _ _ CGA _ _ _ _ _ _  
_ _ _ CGC _ _ _ _ _ _  
_ _ _ CDA _ _ _ _ _ _  
_ _ _ CDC _ _ _ _ _ _  
_ _ _ DAA _ _ _ _ _ _  
_ _ _ DCA _ _ _ _ _ _  
_ _ _ DCC _ _ _ _ _ _  
_ _ _ DGA _ _ _ _ _ _  
_ _ _ DGC _ _ _ _ _ _  
_ _ _ DDA _ _ _ _ _ _  
_ _ _ DDC _ _ _ _ _ _  
_ _ _ DFA _ _ _ _ _ _  
_ _ _ DFC _ _ _ _ _ _  
t
4
4
4
4
4
4
4
4
1"  
1-1/2"  
2"  
t
t
t
2.4"  
t
t
t
t
3"  
1/2"  
1"  
Flush Flanged  
2.9"  
1-1/2"  
Seal with Lower  
2"  
1/2"  
1"  
1-1/2"  
2"  
4.1"  
3"  
Table II continued next page  
*
Standard facing 125-250 AARH RF (raised face) serrated finish.  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
**  
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 23  
STR14A  
14G & 17G  
STR12D & 13D  
TABLE II - SEALS (continued)  
Diaphragm  
316L SS  
Hastelloy C  
Hastelloy C  
Monel  
Tantalum  
Tantalum  
Tantalum  
Upper  
Lower  
316 SS  
316 SS  
Hastelloy C  
Monel  
316 SS  
Hastelloy C  
Tantalum Clad  
Upper Insert  
316 SS  
Selection  
_ _ _ _ _ _ BA _ _ _ _  
_ _ _ _ _ _ BB _ _ _ _  
_ _ _ _ _ _ BC _ _ _ _  
_ _ _ _ _ _ BE _ _ _ _  
_ _ _ _ _ _ BF _ _ _ _  
_ _ _ _ _ _ BG _ _ _ _  
_ _ _ _ _ _ BH _ _ _ _  
Selection  
1
1
1
1
1
1
Wetted Material  
10 10 10  
Non-Wetted Material  
(upper, upper insert)  
316 SS  
_ _ _ _ _ _ _ _ 4 _ _ _  
_ _ _ _ _ _ _ _ 5 _ _ _  
Carbon Steel  
316 SS  
Bolts***  
No Selection  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _ _ _ _ _ H _  
_ _ _ _ _ _ _ _ _ _ J _  
_ _ _ _ _ _ _ _ _ _ M _  
_ _ _ _ _ _ _ _ _ _ N _  
_ _ _ _ _ _ _ _ _ _ P _  
_ _ _ _ _ _ _ _ _ _ Q _  
_ _ _ _ _ _ _ _ _ _ R _  
_ _ _ _ _ _ _ _ _ _ S _  
None  
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
Klinger C-4401  
Flushing  
Connections  
and Plugs**  
(Metal plug material  
will be the same as  
Lower material, if  
metal plug is chosen -  
(SS Plug for CS Lower  
and Tantalum Clad)  
Flush Flanged  
Seal with Lower  
_ _ _ _ _ _ _ _ _ _ _ K  
c
c
c
(non-asbestos)  
Grafoil  
Teflon  
Gylon 3510  
_ _ _ _ _ _ _ _ _ _ _ G  
_ _ _ _ _ _ _ _ _ _ _ T  
_ _ _ _ _ _ _ _ _ _ _ L  
c
d
c
d
c
d
Gasket  
Standard facing 125-250 AARH RF (raised face) serrated finish.  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
Bolt material will be same as Upper Material. However, if Table III bolt/nut option is chosen, seal bolt material will be the same.  
Table II continued below  
*
**  
***  
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.  
STR14A  
14G & 17G  
STR12D & 13D  
Selection  
TABLE II - SEALS (continued)  
Flange  
Size  
Diaphragm  
Diameter  
Flange Pressure Rating *  
ANSI Class 150  
ANSI Class 300  
DIN DN80-PN40  
ANSI Class 150  
ANSI Class 300  
DIN DN100-PN40  
3"  
_ _ _ EFA _ _ _ _ _ _  
_ _ _ EFC _ _ _ _ _ _  
_ _ _ EFM _ _ _ _ _ _  
_ _ _ FGA _ _ _ _ _ _  
_ _ _ FGC _ _ _ _ _ _  
_ _ _ FGP _ _ _ _ _ _  
Selection  
_ _ _ _ _ _ EA _ _ _ _  
_ _ _ _ _ _ EB _ _ _ _  
_ _ _ _ _ _ EC _ _ _ _  
_ _ _ _ _ _ _ _ 7 _ _ _  
_ _ _ _ _ _ _ _ 8 _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 2 _  
_ _ _ _ _ _ _ _ _ _ 4 _  
_ _ _ _ _ _ _ _ _ _ 6 _  
(2.8" OD  
extension)  
4"  
2.8"  
3.5"  
(3.70" OD  
extension  
Diaphragm  
316L SS  
Ext. Tube  
316 SS  
Flange Seal  
with Extended  
Diaphragm  
Wetted Material  
Hastelloy C  
Hastelloy C  
316 SS  
Hastelloy C  
Non-Wetted  
Material (flange)  
Bolts  
CS (Nickel Plated)  
316 SS  
No Selection  
2"  
4"  
6"  
Extension Length  
No Selection  
No Selection  
No Selection  
_ _ _ _ _ _ _ _ _ _ _ 0  
Table II continued next page  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 24  
STR14A  
14G & 17G  
STR12D & 13D  
Selection  
TABLE II - SEALS (continued)  
Flange  
Flange Pressure Rating  
Dependent on Customer Flange  
Diaphragm  
Diameter  
Size  
ANSI Class 150/300/600  
3.5"  
3"  
_ _ _ GFA _ _ _ _ _ _  
Diaphragm  
316L SS  
Body  
316 SS  
_ _ _ _ _ _ GA _ _ _ _  
_ _ _ _ _ _ GB _ _ _ _  
_ _ _ _ _ _ GC _ _ _ _  
_ _ _ _ _ _ GE _ _ _ _  
_ _ _ _ _ _ GG _ _ _ _  
1
1
1
Hastelloy C  
Hastelloy C  
Monel  
316 SS  
Wetted Material  
Hastelloy C  
Monel  
Tantaluma  
Tantalum  
Non-Wetted Material  
Bolts  
No Selection  
_ _ _ _ _ _ _ _ 0 _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ A _  
_ _ _ _ _ _ _ _ _ _ B _  
_ _ _ _ _ _ _ _ _ _ C _  
_ _ _ _ _ _ _ _ _ _ D _  
_ _ _ _ _ _ _ _ _ _ _ 0  
_ _ _ _ _ _ _ _ _ _ _ H  
_ _ _ _ _ _ _ _ _ _ _ J  
_ _ _ _ _ _ _ _ _ _ _ M  
_ _ _ _ _ _ _ _ _ _ _ N  
_ _ _ _ _ _ _ _ _ _ _ P  
_ _ _ _ _ _ _ _ _ _ _ Q  
_ _ _ _ _ _ _ _ _ _ _ R  
_ _ _ _ _ _ _ _ _ _ _ S  
5
5
5
6
6
6
6
6
6
6
6
5
5
5
6
6
6
6
6
6
6
6
5
5
5
6
6
6
6
6
6
6
6
No Selection  
None  
Calibration Rings  
316 SS  
Hastelloy C  
Pancake Seal  
Monel  
Flushing  
None  
Connections  
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
and Plugs***  
(Metal plug material  
will be the same as  
Cal. Ring material, if  
metal plug is chosen -  
SS Plug for CS Lower)  
Table II continued below  
Standard facing 125-250 AARH RF (raised face) serrated finish.  
*
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
Tantalum Body has Tantalum wetted parts and 316 SS non-wetted parts  
***  
a
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.  
STR14A  
STR12D & 13D  
Selection  
14G & 17G  
TABLE II - SEALS (continued)  
Flange  
Size  
Diaphragm  
Diameter  
Flange Pressure Rating *  
Taylor  
Wedge 5"  
O.D.  
Chemical Tee  
"Taylor" Wedge  
3.5"  
750 psi  
_ _ _ HM0 _ _ _ _ _ _  
v
Diaphragm  
316L SS  
Hastelloy C  
Hastelloy C  
Body  
316 SS  
316 SS  
Selection  
_ _ _ _ _ _ HA _ _ _ _  
_ _ _ _ _ _ HB _ _ _ _  
_ _ _ _ _ _ HC _ _ _ _  
_ _ _ _ _ _ _ _ 0 _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _ _ _ _ _ _ 0  
Wetted Material  
Hastelloy C  
Non-Wetted Material  
Bolts  
No Selection  
No Selection  
No Selection  
No Selection  
Styles  
No Selection  
Table II continued next page  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 25  
STR14A  
14G & 17G  
TABLE II - SEALS (continued)  
Pressure Rating  
Threaded Process  
Connection Size  
(NPT Female)  
STR12D & 13D  
Selection  
Diaphragm  
Diameter  
304 SS  
CS Bolts  
Bolts  
1/2" NPT  
3/4" NPT  
1" NPT  
_ _ _ JJG _ _ _ _ _ _  
_ _ _ JKG _ _ _ _ _ _  
_ _ _ JLG _ _ _ _ _ _  
_ _ _ KJG _ _ _ _ _ _  
_ _ _ KKG _ _ _ _ _ _  
_ _ _ KLG _ _ _ _ _ _  
_ _ _ LJG _ _ _ _ _ _  
_ _ _ LKG _ _ _ _ _ _  
_ _ _ LLG _ _ _ _ _ _  
Selection  
t
4
4
4
1250  
2500 psi  
psi  
2.4"  
2.9"  
4.1"  
t
t
1/2" NPT  
3/4" NPT  
1" NPT  
1250  
2500 psi  
psi  
1/2" NPT  
3/4" NPT  
1" NPT  
1500 psi 750 psi  
Diaphragm  
316L SS  
316L SS  
Hastelloy C  
Lower  
Carbon Steel  
316 SS  
_ _ _ _ _ _ JA _ _ _ _  
_ _ _ _ _ _ JB _ _ _ _  
_ _ _ _ _ _ JC _ _ _ _  
_ _ _ _ _ _ JD _ _ _ _  
_ _ _ _ _ _ JE _ _ _ _  
_ _ _ _ _ _ JF _ _ _ _  
_ _ _ _ _ _ JG _ _ _ _  
_ _ _ _ _ _ _ _ A _ _ _  
_ _ _ _ _ _ _ _ C _ _ _  
_ _ _ _ _ _ _ _ _ C _ _  
_ _ _ _ _ _ _ _ _ D _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _ _ _ _ _ H _  
_ _ _ _ _ _ _ _ _ _ J _  
_ _ _ _ _ _ _ _ _ _ M _  
_ _ _ _ _ _ _ _ _ _ N _  
_ _ _ _ _ _ _ _ _ _ P _  
_ _ _ _ _ _ _ _ _ _ Q _  
_ _ _ _ _ _ _ _ _ _ R _  
_ _ _ _ _ _ _ _ _ _ S _  
1
1
1
w
1
1
316 SS  
Wetted Material  
Hastelloy C  
Monel  
316 SS  
Hastelloy C  
Monel  
Tantalum  
Tantalum  
Seal with  
Threaded  
Process  
Hastelloy C  
1
1
CS (Nickel Plated)  
w
1
w
1
Non-Wetted Material  
(upper)  
Stainless Steel  
Carbon Steel  
Connection  
Bolts*  
304 SS  
Flushing  
None  
Connections  
One 1/4" with plastic plug  
One 1/4" with metal plug  
Two 1/4" with plastic plugs  
Two 1/4" with metal plugs  
One 1/2" with plastic plug  
One 1/2" with metal plug  
Two 1/2" with plastic plugs  
Two 1/2" with metal plugs  
Klinger C-4401  
and Plugs**  
(Metal plug material  
will be the same as  
Lower material, if  
metal plug is chosen -  
(SS Plug for CS Lower  
and Tantalum Clad)  
11 11 11  
11 11 11  
11 11 11  
11 11 11  
_ _ _ _ _ _ _ _ _ _ _ K  
c
c
c
(non-asbestos)  
Grafoil  
Gasket  
_ _ _ _ _ _ _ _ _ _ _ G  
_ _ _ _ _ _ _ _ _ _ _ T  
_ _ _ _ _ _ _ _ _ _ _ L  
c
d
c
d
c
d
Teflon  
Gylon 3510  
Table II continued next page  
*
If Table III Bolt/Nut option is chosen, Seal bolts will ship as same material, and MAWP may change.  
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation  
**  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 26  
STR14A  
14G & 17G  
STR12D & 13D  
Selection  
TABLE II - SEALS (continued)  
Diaphragm  
Flange  
Pressure Rating  
Diameter  
Size  
1.9"  
2.4"  
2.9"  
4.1"  
2"  
_ _ _ MD0 _ _ _ _ _ _  
_ _ _ NE0 _ _ _ _ _ _  
_ _ _ PF0 _ _ _ _ _ _  
_ _ _ QG0 _ _ _ _ _ _  
Selection  
2-1/2"  
3"  
t
Customer clamp rating or 600  
psi, whichever is less  
4"  
Diaphragm  
Body  
Wetted Material  
316L SS  
316 SS  
_ _ _ _ _ _ N A _ _ _ _  
Sanitary Seal  
Non-Wetted Material  
No Selection  
_ _ _ _ _ _ _ _ 0 _ _ _  
Bolts  
Styles  
Gasket  
No Selection  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 8 _  
_ _ _ _ _ _ _ _ _ _ _ 0  
Tri-Clover Tri-Clamp  
No Selection  
Size and  
Diaphragm  
Bolt  
Seal Pressure Rating * *  
Selection  
Diameter  
C.S. Bolts  
304 SS Bolts  
Pattern  
2.4"  
_ _ _ RFK _ _ _ _ _ _  
_ _ _ RGK _ _ _ _ _ _  
_ _ _ RPK _ _ _ _ _ _  
t
t
t
t
4
4
4
4
for 3" Pipe  
8-Bolt  
1500 psi  
1500 psi  
4" pipe  
Design  
2.4"  
for 3" Pipe  
6-Bolt  
1250 psi  
1250 psi  
4" pipe  
_ _ _ RQK _ _ _ _ _ _  
Selection  
Design  
Diaphragm  
Lower Housing  
Carbon Steel  
316 SS  
316L SS  
_ _ _ _ _ _ RA _ _ _ _  
_ _ _ _ _ _ RB _ _ _ _  
_ _ _ _ _ _ RC _ _ _ _  
_ _ _ _ _ _ RD _ _ _ _  
_ _ _ _ _ _ SB _ _ _ _  
316L SS  
Hastelloy C  
Hastelloy C  
316L SS  
316 SS  
Wetted Material  
Hastelloy C  
N/A-Body Only  
N/A-Body Only  
Bolts *, ***  
Saddle Seal  
Hastelloy C  
_ _ _ _ _ _ SC _ _ _ _  
Selection  
Body  
Carbon Steel Carbon Steel  
316 SS 304 SS  
No Selection  
No Selection  
Klinger C-4401  
(non-asbestos)  
Grafoil  
_ _ _ _ _ _ _ _ B _ _ _  
1
1
1
Non-Wetted Material  
_ _ _ _ _ _ _ _ C _ _ _  
_ _ _ _ _ _ _ _ _ 0 _ _  
_ _ _ _ _ _ _ _ _ _ 0 _  
Bolts  
Styles  
_ _ _ _ _ _ _ _ _ _ _ K  
Gasket  
_ _ _ _ _ _ _ _ _ _ _ G  
_ _ _ _ _ _ _ _ _ _ _ T  
_ _ _ _ _ _ _ _ _ _ _ L  
Teflon  
Gylon 3510  
Note: All sanitary seals have dairy grade 3A approval.  
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.  
*
If a Table III Bolt/Nut option is chosen, Seal bolts will ship as same material, and MAWP may change.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 27  
STR14A  
STR12D & 13D  
14G & 17G  
TABLE III - OPTIONS  
Communication Options (Must choose a communications option)  
Analog only (can be configured using appropriate Honeywell DE tool)  
DE Protocol communications  
HART 5.x Protocol compatible electronics  
HART 6.x Protocol compatible electronics  
AN  
DE  
HC  
H6  
FF  
e
e
r
e
e
r
e
e
r
b
FOUNDATION Fieldbus Communications  
Indicating Meter Options  
Analog Meter (0-100 Even 0-10 Square Root)  
Smart Meter  
ME  
SM  
CI  
f
f
b
f
Custom Configuration of Smart Meter  
Local Zero & Span  
Local Zero  
ZS  
LZ  
m
x
m
x
b
Transmitter Housing & Electronics Options  
NAMUR Failsafe Software  
SIL 2 - TÜV Certified transmitter (requires HC or H6 and WP options)  
Lightning Protection  
Custom Calibration and I.D. in Memory  
Transmitter Configuration - (non-Fieldbus)  
15 15 15  
14 14 14  
NE  
SL  
LP  
CC  
TC  
FC  
WP  
WX  
SH  
A1  
15 15 15  
21 21 21  
Transmitter Configuration - (Fieldbus)  
Write Protection (Delivered in the "enabled" position)  
Write Protection (Delivered in the "disabled" position)  
316 SS Electronics Housing - with M20 Conduit Connections  
1/2" NPT to M20 316 SS Conduit Adapter (BASEEFA EEx d IIC)  
1/2" NPT to 3/4" NPT 316 SS Conduit Adapter  
Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit  
Adapter (use for FM and CSA Approvals)  
n
n
u
n
n
u
n
n
u
b
b
A2  
A3  
i
i
i
Stainless Steel Customer Wired-On Tag  
TG  
b
(4 lines, 28 characters per line, customer supplied information)  
Stainless Steel Customer Wired-On Tag (blank)  
End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)  
End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)  
End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)  
End Cap Live Circuit Warning Label in German (only with ATEX 3D)  
Meter Body Options (Seal bolt material depends on Transmitter bolt material)  
A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads  
316 SS Bolts and 316 SS Nuts for Process Heads  
B7M Bolts and Nuts for Process Heads  
TB  
SP  
PG  
TL  
a
a
a
a
a
a
a
a
a
a
a
a
b
GE  
CR  
SS  
B7  
b
Remote Seal Options  
Gold Plated Seal Diaphragm (1 Seal)  
G1  
G2  
N1  
N2  
j
j
j
j
j
j
j
j
Gold Plated Seal Diaphragm (2 Seals)  
Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking  
Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking  
Transmitter Mounting Brackets Options  
Mounting Bracket - Carbon Steel  
Mounting Bracket - 304 SS  
Flat Mounting Bracket  
b
b
MB  
SB  
FB  
Services/Certificates Options  
UM  
0X  
TP  
F1  
F3  
F5  
F6  
FE  
F7  
FG  
F8  
MT  
Users Manual Paper Copy (Standard, HC/H6 or FF ships accordingly)  
Clean Transmitter for Oxygen or Chlorine Service with Certificate  
Over-Pressure Leak Test with F3392 Certificate  
Calibration Test Report and Certificate of Conformance (F3399)  
Certificate of Conformance (F3391)  
Certificate of Origin (F0195)  
FMEDA Certificate (SIL 1) (FC33321)  
SIL Certificate (SIL 2/3) (FC33337)  
NACE Certificate (Process-Wetted & Non-Process Wetted) (FC33339)  
NACE Certificate (Process-Wetted only) (FC33338)  
NACE Certificate (F0198) for all welded meter bodies only  
Marine Type Approvals (DNV, ABS, BV, KR & LR)  
h
h
h
b
b
22 22 22  
o
16  
2
o
b
2
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 28  
STR14A  
14G & 17G  
STR12D & 13D  
TABLE III - OPTIONS (continued)  
Warranty Options  
Additional Warranty - 1 year  
Additional Warranty - 2 years  
Additional Warranty - 3 years  
Additional Warranty - 4 years  
W1  
W2  
W3  
W4  
b
Approval  
Approval Type  
Body  
Location or Classification  
Selection  
No hazardous location approvals  
Explosion Proof  
9X  
Class I, Div. 1, Groups A,B,C,D  
Class II, III Div. 1, Groups E,F,G  
Class I, Div. 2, Groups A,B,C,D  
Class I, II, III, Div. 1, Groups  
A,B,C,D,E,F,G  
Dust Ignition Proof  
Factory  
Non-Incendive  
Mutual  
1C  
2J  
Intrinsically Safe  
Explosion Proof  
Class I, Div. 1, Groups B,C,D  
Class II, III, Div. 1, Groups E,F,G  
Class I, II, III, Div. 1, Groups  
A,B,C,D,E,F,G  
Dust Ignition Proof  
CSA  
Intrinsically Safe  
Intrinsically Safe  
Non-Sparking  
Intrinsically Safe,  
Zone 0/1  
Ex ia IIC T4  
SA  
(Australia)  
4G  
3S  
3D  
3N  
Ex n IIC T6 (T4 with SM option)  
EEx ia IIC T4, T5,T6  
b
EEx d IIC T5, T6,  
Enclosure IP 66/67  
Flameproof, Zone 1  
Non-Sparking, Zone 2  
EEx nA, IIC T6  
ATEX*  
(Honeywell). Enclosure IP 66/67  
Ex II 1 G EEx ia IIC T4, T5, T6  
Ex II 2 G EEx d IIC T5, T6  
Multiple Marking**  
Int. Safe, Zone 0/1, or  
3H  
6D  
Flameproof, Zone 1, or Ex II 3 G EEx nA, IIC T6 (Honeywell)  
Non-Sparking, Zone 2  
Enclosure IP 66/67  
INMETRO  
(Brazil)  
Flameproof, Zone 1  
Ex d IIC T5  
*See ATEX installation requirements in the ST 3000 User's Manual  
**The user must determine the type of protection required for installation of the equipment. The user shall  
then check the box [] adjacent to the type of protection used on the equipment certification nameplate.  
Once a type of protection has been checked on the nameplate, subsequently the equipment shall not be  
reinstalled using any of the other certification types.  
TABLE IV  
Factory Identification  
XXXX  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 29  
RESTRICTIONS  
Restriction  
Available Only With  
Selection  
Not Available With  
Selection  
Letter  
Table  
Table  
a
b
III  
3D or 3H  
Select only one option from this group  
II  
_ _ _ _ _ _ BF _ _ _ _,  
_ _ _ _ _ _ BG _ _ _ _,  
_ _ _ _ _ _ JF _ _ _ _,  
_ _ _ _ _ _ JG _ _ _ _,  
c
d
_ _ _ _ _ _ BF _ _ _ _,  
_ _ _ _ _ _ BG _ _ _ _,  
_ _ _ _ _ _ BH _ _ _ _,  
_ _ _ _ _ _ JF _ _ _ _,  
_ _ _ _ _ _ JG _ _ _ _,  
II  
III  
e
f
4G  
III  
I, II  
III  
SM  
h
i
_ 2 _ - 2 _ _ _ _ _ _ _ _ _ _ _  
1C or 2J  
_ _ _ _ _ _ AF _ _ _ _  
_ _ _ _ _ _ BF _ _ _ _  
_ _ _ _ _ _ BG _ _ _ _  
_ _ _ _ _ _ BH _ _ _ _  
_ _ _ _ _ _ GG _ _ _ _  
_ _ _ _ _ _ JF _ _ _ _  
_ _ _ _ _ _ JG _ _ _ _  
j
II  
III  
III  
m
n
ME, FF  
1C, 2J  
III  
II  
o
CR  
0 _ _ _ _ _ _ _ _ _ _ _,  
2 _ _ _ _ _ _ _ _ _ _ _  
4 _ _ _ _ _ _ _ _ _ _ _  
q
III  
r
TC, ME, 4G, 3S  
s
Must be specified with Model STR12D  
2 _ _ - _ B _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ C _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ D _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ E _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ F _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ H _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ J _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ K _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ L _ _ _ _ _ _ _ _ _ _,  
2 _ _ - _ M _ _ _ _ _ _ _ _ _ _  
t
I & II  
cont’d  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 30  
RESTRICTIONS (continued)  
Restriction  
Available Only With  
Selection  
1C, 2J  
Not Available With  
Selection  
Letter  
u
v
Table  
III  
Table  
I
2 _ _  
II  
w
x
_ _ _ _ _ _ JA _ _ _ _  
III  
FF, SM  
I
2 _ _  
III  
MB, SB, FB  
y
II  
I
_ 2 _ _ _ _ _ _ _ _ _ _  
_ _ D  
z
1
2
3
III  
III  
F7  
FB  
I
5 _ _  
See Figure 23 in Specification  
_ A _ _ _ _ _ _ _ _ _ _,  
_ G _ _ _ _ _ _ _ _ _ _,  
_ B _ _ _ _ _ _ _ _ _ _,  
_ H _ _ _ _ _ _ _ _ _ _,  
_ 2 _ _ _ _ _ _ _ _ _ _,  
4
II  
II  
II  
I
_ _ _ _ _ _ _ _ _ _ _ 0  
_ _ _ _ _ _ _ _ _ _ A _  
1 _ _, 3 _ _  
5
6
7
III  
CR  
CC, G1, G2, N1, N2, OX, TP, MT, TC,  
FC, F1,  
III  
8
9
_ _ _ _ _ _ AA2_ _ _  
_ _ _ _ _ _ AB2_ _ _  
II  
II  
II  
III  
_ _ _ _ _ _ _ _ _ _ _ T  
F7  
10  
_ _ _ _ _ _ _ _ _ _ 0 _  
_ _ _ _ _ _JJG_ _ _  
_ _ _ _ _ _JKG_ _ _  
_ _ _ _ _ _JLG_ _ _  
_ _ _ _ _ _CAA_ _ _  
_ _ _ _ _ _CCA_ _ _  
_ _ _ _ _ _CCC_ _ _  
FF, 00  
11  
II  
III  
HC or H6 and WP  
III  
III  
14  
15  
16  
21  
22  
FF  
I
III  
III  
_ _ C  
FF  
SL  
See ST-83 for Published Specials with pricing.  
See ST-89 and User's Manual for part numbers.  
Note:  
See COMS Order Entry Information including TC, manuals, certificates, drawings and SPINS.  
See ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including factory default values.  
To request a quote for a non-published "special", fax RFQ w/ Application Data Sht (34-ST-18-01) to Mktg. Applications.  
See Specification 34-ST-03-64 for Seal dimensions.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 31  
Dimensions and Drawings  
21a  
21b  
21b  
21a  
21a  
21a  
21a  
21b  
21b  
21a  
21a  
21a  
21a  
21b  
21b  
21a  
21a  
21a  
21a  
21b  
21b  
21a  
21a  
21a  
Figure 21a. Flush Flanged Seal  
Figure 21b. Flush Flanged Seal  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 32  
Dimensions and Drawings, cont.  
Figure 22  
Figure 23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 33  
Dimensions and Drawings, cont.  
Figure 24  
Figure 25  
Figure 26  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 34  
Dimensions and Drawings, cont.  
Figure 27  
Figure 28  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 35  
Dimensions and Drawings, cont.  
Figure 29  
Figure 30  
Figure 31  
Download from Www.Somanuals.com. All Manuals Search And Download.  
34-ST-03-64  
Page 36  
THIS PAGE INTENTIONALLY BLANK  
ST 3000® is a registered trademark of Honeywell International Inc.  
HART* is a trademark of the Hart Communication Foundation.  
FOUNDATION™ is a trademark of the Fieldbus Foundation.  
Honeywell Field Solutions  
Honeywell International Inc.  
2500 W. Union Hill Drive  
Phoenix, Arizona 85027  
©Honeywell International Inc.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Swing PD162294B User Manual
Haier Freezer BD 66A User Manual
HandHeld Entertainment Scanner PC600 User Manual
Honeywell Automobile Parts ML6421 User Manual
Honeywell Home Security System 3 144 User Manual
Hotpoint Washer WMSAQG 621 User Manual
HP Hewlett Packard Printer V85 User Manual
HTC Cell Phone Desire User Manual
IBM Computer Drive 48X 20X User Manual
Image Treadmill IMTL22991 User Manual