34-ST-03-64
2/08
ST 3000 Smart Transmitter
Series 100 Remote Diaphragm Seals Models
Specification and
Model Selection
Guide
STR12D
STR13D
STR14G
STR17G
STR14A
0-10 to 0-400 inH O
0-5 to 0-100 psid
0-5 to 0-500 psig
0-100 to 0-3000 psig 0-7 to 0-210 bar
0-5 to 0-500 psia 0-0.35 to 0-35 bar
0-25 to 0-1000 mbar
0-0.35 to 0-7 bar
0-0.35 to 0-35 bar
2
Introduction
In 1983, Honeywell introduced the first
Smart Pressure Transmitter― the ST
3000®. In 1989, Honeywell launched
the first all digital, bi-directional protocol
for smart field devices. Today, its ST
3000 Series 100 Remote Seal
Transmitters continue to bring proven
“smart” technology to a wide spectrum
of measurement applications. Typical
applications include high accuracy level
measurement in pressurized vessels in
the chemical and hydrocarbon
processing industries. A second
application consists of accurate flow
measurement for slurries and high
viscosity fluids in the chemical industry.
Honeywell remote seal transmitters
demonstrate proven reliability in
hundreds on installations in a wide
variety of industries and applications
with a wide variety of secondary fill
fluids for corrosive or high temperature
process fluids.
All ST 3000 transmitters can provide a
4-20 mA output, Honeywell Digitally
Enhanced (DE) output, HART* output,
or FOUNDATION™ Fieldbus output.
When digitally integrated with
Figure 1—Series 100 Remote Seal Pressure Transmitters feature proven
piezoresistive sensors and advanced seal technology with standard weld
connections.
Honeywell’s Process Knowledge
System™, EXPERION PKS™,
ST 3000 instruments provide a more
accurate process variable as well as
advanced diagnostics.
The devices provide comprehensive self-diagnostics to help users
maintain high uptime, meet regulatory requirements, and attain high
quality standards. S100 transmitters are ideal for critical applications,
such as custody transfer of natural gas and energy and material
balances, where accuracy and stability are of the utmost importance.
Honeywell’s high-performance ST 3000
S100 transmitters lead the industry in:
"Our commitment to Honeywell field instruments is based on
seamless integration with our Honeywell system and the enhanced
fault detection that the Honeywell DE protocol offers. Honeywell
instruments also offer us a better way of ensuring database integrity
over simple analog instruments. In addition, Honeywell's high-quality
support has enabled us to better implement solutions to some of our
more difficult problems. We have used Honeywell differential pressure
smart transmitters for the past eight years. Based on their accuracy
and low failure rates, we are now targeting critical flow applications
that require the robustness that these transmitters bring.”
DCS Systems Engineer
•
•
•
•
•
Accuracy
Stability
Reliability
Rangeability
Warranty
Includes Lifetime™ Transmitters:
•
•
•
•
Total Accuracy = ±0.0375%
Stability = ±0.01% per year
Reliability = 470 years MTBF
Rangeability = 400 to 1
International Integrated Oil Company
•
Lifetime Warranty = 15 years
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 3
Description of Diaphragm Seals
Figure 6 - Seals with Threaded Process
Connections can be used with differential, gauge and
absolute pressure transmitters and are available with
½”, ¾” and 1” NPT Female process connections.
Figure 6
Figure 7 - Sanitary Seals can be used with
differential, gauge and absolute pressure transmitters
and are available with 3” and 4” Tri-Clover-Tri-Clamp
process connections.
Figure 7
Figure 8
Figure 9
Figure 10
Figure 8 - Saddle Seals can be used with differential,
gauge and absolute pressure transmitters and are
available with 3” and 4” (6 bolt or 8 bolt designs)
process connections.
Figure 9 - Calibration Rings are available with Flush
Flange Seals and Pancake Seals. Flushing ports (1/4”
or ½”) are available with calibration rings.
Figure 10 - Stainless Steel Armor and PVC Coated
Stainless Steel Armor Capillaries are available with
Honeywell Remote Seal Solutions.
Figure 11 - 2” Stainless Steel Nipples are available
for Close-Coupled remote seal solutions.
Figure 11
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 4
Figure 12 - Welded Meter Body for All-Welded
Remote Seal Solution. The welded ST 3000 meter
body is an important part of an All-Welded Remote
Seal Solution, which is commonly used in Vacuum
applications.
Figure 12
Description
Features
•
•
Choice of linear or square root
output conformity is a simple
configuration selection.
The ST 3000 transmitter can replace any 4 to 20 mA output
transmitter in use today and operates over a standard two-wire
system.
Direct digital integration with
Experion PKS and other control
systems provides local
measurement accuracy to the
system level without adding
typical A/D and D/A converter
inaccuracies.
The measuring means is a piezoresistive sensor, which actually
contains three sensors in one. It contains a differential pressure
sensor, a temperature sensor, and a static pressure sensor.
Microprocessor-based electronics provide higher span-turndown
ratio, improved temperature and pressure compensation, and
improved accuracy.
•
Unique piezoresistive sensor
automatically compensates input
for temperature and static
pressure. Added “smart”
features include configuring
lower and upper range values,
simulating accurate analog
output, and selecting
The transmitter’s meter body and electronics housing resist shock,
vibration, corrosion, and moisture. The electronics housing contains
a compartment for the single-board electronics, which is isolated
from an integral junction box. The single-board electronics is
replaceable and interchangeable with any other ST 3000 Series 100
or Series 900 model transmitter.
preprogrammed engineering
units for display.
Like other Honeywell transmitters, the ST 3000 features two-way
communication and configuration capability between the operator
and the transmitter through several Honeywell field-rated portable
configuration devices, including the Smart Field Communicator
(SFC) and the Multiple Communication Configurator (MC ToolKit).
While both are made for in-field use, the MC Toolkit also can be
ordered for use in intrinsically safe environments.
•
Smart transmitter capabilities
with local or remote interfacing
means significant manpower
efficiency improvements in
commissioning, start-up, and
ongoing maintenance functions.
The SCT 3000 Smartline® Configuration Toolkit provides an easy
way to configure instruments using a personal computer. The toolkit
enables configuration of devices before shipping or installation. The
SCT 3000 can operate in the offline mode to configure an unlimited
number of devices. The database can then be loaded down-line
during commissioning.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 5
Specifications
Operating Conditions – All Models
Parameter
Reference Condition
Rated Condition
Operative Limits
Transportation and
Storage
°C
°F
°C
°F
°C
°F
°C
°F
Ambient Temperature *
25 ±1
77 ±2
—
—
—
—
–55 to 90 –67 to 194
0 to 100
Humidity
% RH
10 to 55
0 to 100
0 to 100
Maximum Allowable
MAWP is minimum of Body Rating or Seal Rating (See Model Selection Guide for Seal
Working Pressure (MAWP) MAWP)
Body
MAWP
STR12D
STR13D
STR12D
STR13D
STR14G
STR17G
STR14A
2500 psig (172 bar) Bolted Process Heads Table I _ _ A
2500 psig (172 bar) Bolted Process Heads Table I _ _ A
1450 psig (100 bar) All Welded Process Heads Table I _ _ C
1450 psig (100 bar) All Welded Process Heads Table I _ _ C
500 psig (35 bar)
3000psig (207 bar)
500 psia (35 bar).
Vacuum Region - Minimum
Pressure
mmHg absolute
Atmospheric (See Figure 15 for vacuum limitations.)
Supply Voltage, Current,
and Load Resistance
Voltage Range:
Current Range:
Load Resistance:
10.8 to 42.4 Vdc at terminals
3.0 to 21.8 mA
0 to 1440 ohms (as shown in Figure 16)
* Ambient Temperature Limit is a function of Process Interface Temperature. (See Figure 13.)
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 6
Performance Under Rated Conditions * - Model STR12D (0-10 to 0-400 inH O)
2
Parameter
Description
Upper Range Limit **
inH2O 400 (39.2°F/4°C is standard reference temperature for inH O range.)
2
mbar
1000
Minimum Span
Turndown Ratio
inH2O 10 Note: Recommended minimum span in square root mode is 20 inH O (50 mbar).
2
mbar
25
40 to 1
Zero Elevation and Suppression No limit except minimum span within ±100% URL.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.2% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
For URV below reference point (50 inH O), accuracy equals:
2
• Accuracy includes residual error
after averaging successive
readings.
50 inH O
2
125 mbar
span mbar
⎛
⎝
⎞
⎠
±0.1 + 0.1
or ±0.1 + 0.1
in % of span
(
)
span inH O
2
In Digital Mode: ±0.175% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
For URV below reference point (50 inH O), accuracy equals:
2
50 inH O
span inH O
2
125 mbar
span mbar
⎛
⎝
⎞
⎠
±0.075 + 0.10
or ±0.075 + 0.10
in % of span
(
)
2
Combined Zero and Span
Temperature Effect per 28°C
(50°F) ***
In Analog Mode: ±1.2% of span.
For URV below reference point (200 inH O), effect equals:
2
200 in H2O
500 mbar
⎛
⎝
⎛
⎝
⎞
⎠
⎞
⎠
±0.2 + 1.0
or ±0.2 + 1.0
In % span
span in H2O
span mbar
In Digital Mode: ±1.175% of span.
For URV below reference point (200 inH O), effect equals:
2
200 in H2O
500 mbar
⎛
⎝
⎛
⎝
⎞
⎠
⎞
⎠
In % span
or ±0.175 + 1.0
±0.175 + 1.0
span in H2O
span mbar
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
*** Specification applies to transmitters with 2 seals only. Apply 1.5 times factor to temperature effect for capillary lengths greater than 10
feet.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 7
Performance Under Rated Conditions * - Model STR13D (0-5 to 0-100 psid)
Parameter
Description
Upper Range Limit **
psid 100
bar
7
Minimum Span
Turndown Ratio
psid
bar 0.35
5
20 to 1
Zero Elevation and Suppression No limit except minimum span within –18% and +100% of URL. Specifications valid from
–5% to 100% of URL.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
For URV below reference point (30 psi), accuracy equals:
• Stated accuracy does not apply
for models with 2.9 inch
diameter remote seal
diaphragms.
30 psi
(span psi)
2 bar
(span bar)
±0.05 + 0.05
or ±0.05 + 0.05
in % of span
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
greater, terminal based.
• Accuracy includes residual error
after averaging successive
readings.
For URV below reference point (30 psi), accuracy equals:
30 psi
(span psi)
2 bar
(span bar)
±0.025 + 0.05
or ±0.025 + 0.05
in % of span
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
Combined Zero and Span
Temperature Effect per 28°C
(50°F) ***
In Analog Mode: ±0.33% of span.
For URV below reference point (60 psi), effect equals:
60 psi
4 bar
⎛
⎝
⎞
⎠
⎛
⎝
⎞
⎠
or ±0.05 + 0.28
In % span
±0.05 + 0.2
span psi
span bar
In Digital Mode: ±0.305% of span.
For URV below reference point (60 psi), effect equals:
60 psi
4 bar
⎛
⎝
⎞
⎠
⎛
⎝
⎞
⎠
or ±0.025 + 0.28
In % span
±0.025 + 0.25
span psi
span bar
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
*** Specification applies to transmitters with 2 seals only. Apply 1.5 times factor to temperature effect for capillary lengths greater than 10
feet.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 8
Performance Under Rated Conditions * - Model STR14G (0-5 to 0-500 psig)
Parameter
Description
Upper Range Limit **
psig 500
bar 35
Minimum Span
Turndown Ratio
psig
bar 0.35
5
100 to 1
Zero Elevation and Suppression No limit except minimum span from absolute zero to 100% of URL. Specifications valid
over this range.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is
greater.
For URV below reference point (20 psi), accuracy equals:
• Accuracy includes residual error
after averaging successive
readings.
20 psi
(span psi)
1.4 bar
(span bar)
±0.05 + 0.05
or ±0.05 + 0.05
in % of span
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
greater.
For URV below reference point (20 psi), accuracy equals:
20 psi
(span psi)
1.4 bar
(span bar)
±0.025 + 0.05
or ±0.025 + 0.05
in % of span
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 9
Performance Under Rated Conditions * - Model STR17G (0-100 to 0-3000 psig)
Parameter
Description
Upper Range Limit **
psig 3000
bar 210
Minimum Span
Turndown Ratio
psig 100
bar
7
30 to 1
Zero Elevation and Suppression No limit except minimum span from absolute zero to 100% of URL. Specifications valid
over this range.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.15% of calibrated span or upper range value (URV), whichever is
greater.
For URV below reference point (300 psi), accuracy equals:
• Accuracy includes residual error
after averaging successive
readings.
300 psi
(span psi)
21 bar
(span bar)
±0.10 + 0.05
or ±0.10 + 0.05
in % of span
In Digital Mode: ±0.125% of calibrated span or upper range value (URV), whichever is
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
greater.
For URV below reference point (300 psi), accuracy equals:
300 psi
(span psi)
21 bar
(span bar)
±0.075 + 0.05
or ±0.075 + 0.05
in % of span
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 10
Performance Under Rated Conditions * - Model STR14A (0-5 to 0-500 psia)
Parameter
Description
Upper Range Limit **
psia 500
bar absolute 35
Minimum Span
Turndown Ratio
psia
5
bar absolute 0.35
100 to 1
Zero Elevation and Suppression No limit except minimum span from 0 to 100% URL.
Accuracy (Reference – Includes
combined effects of linearity,
hysteresis, and repeatability)
In Analog Mode: ±0.1% of calibrated span or upper range value (URV), whichever is
greater.
For URV below reference point (20 psi), accuracy equals:
• Accuracy includes residual error
after averaging successive
readings.
20 psi
(span psi)
1.4 bar
(span bar)
±0.05 + 0.05
or ±0.05 + 0.05
in % of span
In Digital Mode: ±0.075% of calibrated span or upper range value (URV), whichever is
• For FOUNDATION Fieldbus use
Digital Mode specifications. For
HART use Analog Mode
specifications.
greater.
For URV below reference point (20 psi), accuracy equals:
20 psi
(span psi)
1.4 bar
(span bar)
±0.025 + 0.05
or ±0.025 + 0.05
in % of span
*
Performance specifications are based on reference conditions of 25°C (77°F), zero (0) static pressure, 10 to 55% RH, and
316L Stainless Steel barrier diaphragm.
** Transmitter URL limit or maximum seal pressure rating, whichever is lower.
Performance Under Rated Conditions – General for all Models
Parameter
Description
Output (two-wire)
Analog 4 to 20 mA or digital communications DE mode. Options available for
FOUNDATION Fieldbus and HART protocol.
Supply Voltage Effect
±0.005% of span per volt.
Damping Time Constant
RFI Protection (Standard)
CE Conformity (Europe)
Adjustable from 0 to 32 seconds digital damping.
Negligible (20 to 1000 MHz at 30 volts per meter).
89/336/EEC, Electromagnetic Compatibility (EMC) Directive.
NAMUR NE 43 Compliance
Option
Transmitter failure information is generated when the measuring information is invalid or
no longer present. Failure information is transmitted as a current signal but outside the
normal 4-20 mA measurement signal level. Transmitter failure values are: ≤ 3.6 mA and
≥ 21.0 mA. The normal signal range is ≥ 3.8 mA and ≤ 20.5 mA.
SIL 2/3 Compliance
SIL certified to IEC 61508 for non-redundant use in SIL 2 related Safety Systems
(single use) and for redundant (multiple) use in SIL 3 Safety Systems through
TÜV Nord Sys Tec GmbH & Co. KG under the following standards: IEC61508-1: 1998;
IEC 61508-2: 2000; IEC61508-3: 1998.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 11
Physical and Approval Bodies
Parameter
Description
Process Interface
See Model Selection Guide for Material Options for desired seal type.
316L Stainless Steel, Monel, Hastelloy C, Tantalum
Seal Barrier Diaphragm
Seal Gasket Materials
Mounting Bracket
Klinger C-4401 (non-asbestos)
Grafoil
Teflon
Gylon 3510
Carbon Steel (Zinc-Chromate plated) or Stainless Steel.
Fill Fluid (Meter Body)
Silicone (DC 200)
CTFE (Chlorotrifluoroethylene)
S.G. @ 25°C = 0.94
S.G. @ 25°C = 1.89
Fill Fluid (Secondary)
Silicone (DC 200)
CTFE (Chlorotrifluoroethylene)
Silicone (DC 704)
NEOBEE M-20
S.G. @ 25°C = 0.94
S.G. @ 25°C = 1.89
S.G. @ 25°C = 1.07
S.G. @ 25°C = 0.90
S.G. @ 25°C = 0.93
Syltherm 800
Electronic Housing
Capillary Tubing
Epoxy-Polyester hybrid paint. Low copper-aluminum alloy. Meets NEMA 4X (watertight)
and NEMA 7 (explosion proof). Stainless steel optional.
Armored Stainless Steel or PVC Coated Armored Stainless Steel.
Length: 5, 10, 15, 20, 25, and 35 feet (1.5, 3, 4.6, 6.1, 7.5, and 10.7 meters).
A 2 inch (51 millimeter) S.S. close-coupled nipple is also available. See Model Selection
Guide. Refer to Figure 14 for guide to maximum capillary length vs. diaphragm diameter.
Wiring
Accepts up to 16 AWG (1.5 mm diameter).
See Figure 17.
Mounting
Dimensions
Net Weight
Transmitter: See Figures 20a and 20b. Seal: See Figures 21 through 31.
Transmitter: 15.4 pounds (7 Kg). Total weight is dependent on seal type and capillary
length.
Approval Bodies
Factory Mutual
Explosion Proof: Approved as Explosion Proof for Class I, Division 1, Groups A, B,
C, D locations,
Dust Ignition Proof: Approved as Dust Ignition Proof for Class II, III, Division 1,
Groups E, F, G locations,
Intrincically Safe: Approved as Intrinsically Safe for for Class I, II, III, Division 1,
Groups A, B, C, D, E, F, G locations.
Nonincendive: Approved as Nonincendive for Class I, Division 2, Groups A, B, C, D
locations.
Explosion Proof: Approved as Explosion Proof for Class I, Division 1, Groups B, C,
D locations,
Dust Ignition Proof: Approved as Dust Ignition Proof for Class II, III, Division 1,
Groups E, F, G locations,
CSA
Intrincically Safe: Approved as Intrinsically Safe for Class I, II, III, Division 1, Groups
A, B, C, D, E, F, G locations.
Canadian Registration
Number (CRN)
All ST 3000 model designs, except SATG19L, STG99L, STG170 and STG180 have
been registered in all provinces and territories in Canada and are marked
CRN:0F8914.5c.
Intrinsically Safe, Zone 0/1: EEx ia IIC T4, T5, T6
Flameproof/Zone 1:
Non-Sparking, Zone 2:
Multiple Markings:
EEx d IIC T5, T6 (enclosure IP 66/67)
EEx nA, IIC T6 (enclosure IP 66/67)
Ex II 1 G: EEx ia IIC T4, T5, T6, Ex II 2 G: EExd IIC T5, T6
Ex II 3 G: EEx nA, IIC T6 (Honeywell) (enclosure IP 66/67)
ATEX
Intrinsically Safe: EX ia IIC T4
Non-Sparking: Ex n IIC T6 (T4 with SM option)
SA (Australian)
INMETRO (Brazil)
Flame-Proof, Zone 1: EX d IIC T5
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 12
Parameter
Description
Pressure Equipment Directive
(97/23/EC)
The ST 3000 pressure transmitters listed in this Specification have no pressurized
internal volume or have a pressurized internal volume rated less than 1,000 bar (14,500
psig) and/or have a maximum volume of less than 0.1 liter. Therefore, these
transmitters are either; not subject to the essential requirements of the directive
97/23/EC (PED, Annex 1) and shall not have the CE mark, or the manufacturer has the
free choice of a module when the CE mark is required for pressures > 200 bar (2,900
psig).
NOTE: Pressure transmitters that are part of safety equipment for the protection of piping (systems) or vessel(s) from
exceeding allowable pressure limits, (equipment with safety functions in accordance with Pressure Equipment Directive
97/23/EC article 1, 2.1.3), require separate examination.
200
185
165
180
160
140
120
100
80
140
Maximum Ambient
Temperature (°F)
60
40
20
0
200
Process Interface Temperature (°F)
350
450
Figure 13—Ambient temperature and process interface chart.
Transmitter Minimum Span and Maximum Capillary Length
Minimum recommended span for STR12D and STR13D DP Transmitter with two Remote Seals
Diaphragm
Capillary
10'
-
125 iwc
20 iwc
15 iwc
Capillary Length
Size
2.4
2.9
3.5
4.1
5'
15'
-
150 iwc
24 iwc
18 iwc
20'
-
175 iwc
28 iwc
21 iwc
30'
-
-
36 iwc
27 iwc
35'
-
-
40 iwc
30 iwc
maximum
200 iwc
100 iwc
16 iwc
12 iwc
5'
20'
35'
35'
Minimum recommended span for STR12D and STR13D DP Transmitter with one Remote Seal
Diaphragm
Direct
Mount
20 psig
10 psig
50 iwc
40 iwc
Capillary
10'
-
20 psig
100 iwc
80 iwc
Capillary Length
Size
2.4
2.9
3.5
4.1
5'
15'
-
25 psig
120 iwc
100 iwc
20'
-
30 psig
140 iwc
120 iwc
30'
-
-
180 iwc
160 iwc
35'
-
-
200 iwc
180 iwc
maximum
30 psig
15 psig
80 iwc
60 iwc
5'
20'
35'
35'
Minimum recommended span for STR14G, STR14A, STR17G Transmitter with Remote Seal
Diaphragm
Direct
Mount
25 psi
10 psi
8 psi
Capillary
10'
40 psi
20 psi
10 psi
5 psi
Capillary Length
Size
2.0
2.4
2.9
3.5
4.1
5'
15'
20'
-
30 psi
12 psi
5 psi
5 psi
30'
-
40 psi
14 psi
7 psi
7 psi
35'
-
50 psi
15 psi
8 psi
8 psi
maximum
30 psi
15 psi
9 psi
5 psi
5 psi
50 psi
25 psi
11 psi
5 psi
15'
35'
35'
35'
35'
5 psi
5 psi
5 psi
5 psi
Minimum span is the higher of the value from the table above or the value defined under Performance Conditions for the range transmitter
Figure 14—Maximum capillary length and diaphragm size chart.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 13
Figure 15—ST 3000 Remote Seals operable limits for pressure vs. temperature.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 14
1440
1200
Note: A minimum of 250 ohms
of loop resistance is necessary
to support communications.
Loop resistance equals barrier
resistance plus wire resistance
plus receiver resistance.
Loop
Resistance
(ohms)
800
650
450
250
= Operating Area
0
10.8
16.28 20.63 25 28.3 37.0
42.4
Operating Voltage (Vdc)
Figure 16—Supply voltage/loop resistance chart.
LP Side
Maximum level
H2
Fixed
ref. leg
Variable
Head
H1
Minimum level
.
24249
HP Side
NOTE: Lower flange seal should not be mounted over 22 feet below or above
the transmitter for silicone fill fluid (11 feet for CTFE fill fluid) with tank at one
atmosphere. The combination of tank vacuum and high pressure capillary
head effect should not exceed 9 psi vacuum (300 mmHg absolute).
Consult Honeywell for installation of STR13D.
Figure 17—The ST 3000 transmitter with remote diaphragm seals shown mounted on a tank.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 15
Application Data*
Max
Level
LP
Liquid Level: Closed Tank
Determine the minimum and
maximum pressure differentials to
be measured (Figure 18).
b
P
Min
= (SG x a) – (SG x d)
p
f
Min
Level
= LRV when HP at bottom
of tank
HP
a
= –URV when LP at
bottom of tank
Transmitter above datum
P
Max
= (SG x b) – (SG x d)
p
f
= URV when HP at bottom
of tank
Max
Level
LP
= –LRV when LP at bottom
of tank
Where:
Minimum level at 4 mA
b
Maximum level at 20 mA
Min
Level
HP
a
a = distance between bottom
tap and minimum level
Transmitter at datum
b = distance between bottom
tap and maximum level
d = distance between taps
Max
LP
Level
SG = Specific Gravity of capillary
f
fill fluid (see page 11 for
values)
SG = Specific Gravity of
p
b
process fluid
Min
HP
Level
a
Transmitter below datum
24253
Figure 18—Closed tank liquid level measurement distances.
* Contact STC-Phoenix concerning
applications for model STR13D.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 16
Density or Interface*
Calculate the minimum and
maximum pressure differentials to
be measured.
P
min
= (SG
- SG ) x (d);
min
LP
f
minimum density, 4mA
output
P
max
= (SG
- SG ) x (d);
max
f
maximum density, 20mA
output
Where:
HP
d = distance between the
taps
24257
SG
= maximum Specific
Gravity
max
SG
= minimum Specific
Gravity
min
SGf = Specific Gravity of
capillary fill fluid (see
page 11 for values)
Figure 19—Density, direct acting instrument configuration.
* Contact STC-Phoenix concerning
applications for model STR13D.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 17
82.9
3.26
94.9
3.74
65.1
2.56
With Smart meter
With Analog
meter
53.1
3.6
135
5.32
Reference
Dimensions:
millimeters
inches
Removal 45.7
Clearance 1.8
for All Caps
2.09
0.14
Plug
Without Without
meter
meter
55.3
2.18
Optional
meters
23.5
.925
Rotational
lock
Optional external
ground
STR12D, STR13D
DP/I Remote Seal
with Horizontal
Pipe Mount
LP seal
omitted for
clarity
85
3.35
42.5
1.67
50
1.97
82.9
3.26
94.9
3.74
With Smart meter
With Analog meter
53.1
2.09
65.1
2.56
3.6
0.14
Removal
45.7
135
Plug
Clearance
Without Without
5.32
1.8
meter
meter
for All Caps
55.3
2.18
Optional
meters
STR14A
23.5
.925
AP/I Remote Seal
with Horizontal
Pipe Mount
Rotational
lock
Optional external
ground
Seal
omitted
for clarity
71.1
2.80
SQ.
82.9
3.26
94.9
3.74
With Smart meter
With Analog meter
53.1
65.1
2.56
Removal 45.7
Clearance 1.8
for All Caps
2.09
135
5.32
3.6
0.14
Plug
Without Without
meter
meter
55.3
2.18
STR14G, STR17G
Optional
meters
LGP/I Remote Seal
with Horizontal
Pipe Mount
23.5
.925
Rotational
lock
Optional external
ground
Seal
omitted
for clarity
24261
Figure 20a —Approximate horizontal mounting dimensions for Remote Seal Transmitter.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 18
82.9
3.26
94.9
3.74
65.1
2.56
With Smart meter
With Analog
meter
53.1
Reference
Dimensions:
millimeters
inches
3.6
135
5.32
Removal 45.7
Clearance 1.8
for All Caps
2.09
0.14
Plug
Without Without
meter
meter
55.3
2.18
Optional
meters
23.5
.925
LP seal
omitted
for clarity
Rotational
lock
Optional external
ground
STR12D, STR13D
DP/I Remote Seal
with Vertical
85
3.35
SQ
Pipe Mount
50
1.97
42.5
1.67
82.9
3.26
94.9
3.74
65.1
2.56
With Smart meter
With Analog
meter
53.1
Removal
3.6
0.14
45.7
1.8
2.09
135
5.32
Plug
Clearance
for All Caps
Without Without
STR14A
meter
meter
AP/I Remote Seal
with Vertical
Pipe Mount
55.3
2.18
Optional
meters
23.5
.925
Rotational
lock
Optional external
ground
Seal
omitted
for clarity
71.1
2.80
SQ.
82.9
3.26
94.9
3.74
65.1
2.56
With Smart meter
With Analog
meter
53.1
Removal 45.7
Clearance 1.8
for All Caps
2.09
135
5.32
3.6
0.14
Plug
Without Without
STR14G, STR17G
LGP/I Remote Seal
with Vertical Pipe
Mount (Flat Bracket)
meter
meter
55.3
2.18
23.5
.925
Optional
meters
Rotational
lock
Optional external
ground
Seal
omitted
for clarity
24262
Figure 20b —Approximate vertical mounting dimensions for Remote Seal Transmitter.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 19
Options
NAMUR NE43 Compliance
Ordering Information
Mounting Bracket
Contact your nearest Honeywell sales
office, or
The angle mounting bracket is
available in either zinc-plated
carbon steel or stainless steel and
is suitable for horizontal or vertical
mounting on a two inch (50
millimeter) pipe, as well as wall
mounting. An optional flat
mounting bracket is also available
in carbon steel for two inch (50
millimeter) pipe mounting.
(Option NE)
This option provides software the
meets the NAMUR NE43
In the U.S.:
requirements for failsafe software.
Transmitter failure information is
generated when the measuring
information is no longer valid.
Transmitter failure values are:
≤ 3.6 mA and ≥ 21.0 mA. The
normal ST 3000 ranges are ≤ 3.8
mA and ≥ 20.5 mA.
Honeywell
Industrial Automation & Control
16404 North Black Canyon Hwy.
Phoenix, AZ 85053
1-800-288-7491
In Canada:
The Honeywell Centre
155 Gordon Baker Rd.
North York, Ontario M2H 3N7
1-800-461-0013
Indicating Meter
(Options ME and SM)
Lightning Protection
(Option LP)
Two integral meter options are
available. An analog meter (option
ME) is available with a 0 to 100%
linear scale. The Smart Meter
(option SM) provides an LCD
display for both analog and digital
output and can be configured to
display pressure in pre-selected
engineering units.
A terminal block with circuitry that
protects the transmitter from
transient surges induced by
nearby lightning strikes is
available.
In Latin America:
Honeywell Inc.
480 Sawgrass Corporate Parkway,
Suite 200
Sunrise, FL 33325
(954) 845-2600
Indicator Configuration
(Option CI)
Provides custom configuration of
Smart Meters
In Europe and Africa:
Honeywell S. A.
HART® Protocol Compatibility
(Options HC and H6)
Optional electronics modules for
the ST 3000 provides HART
Protocol compatibility in either
HART 5.x or 6.x formats.
Avenue du Bourget 1
1140 Brussels, Belgium
Tagging (Option TG)
Up to 30 characters can be added
on the stainless steel nameplate
mounted on the transmitter’s
electronics housing at no extra
cost. Note that a separate
nameplate on the meter body
contains the serial number and
body-related data. A stainless
steel wired on tag with additional
data of up to 4 lines of 28
In Eastern Europe:
Honeywell Praha,
s.r.o. Budejovicka 1
140 21 Prague 4,
Czech Republic
Transmitters with a HART Option
are compatible with any HART
enabled system that provides 5.x
or 6.x format support.
In the Middle East:
Honeywell Middle East Ltd.
Khalifa Street,
FOUNDATION Fieldbus
(Option FF)
Sheikh Faisal Building
Abu Dhabi, U. A. E.
characters is also available. The
number of characters for tagging
includes spaces.
Equips transmitter with FF
protocol for use in 31.25 kbit/s FF
networks. See document 34-ST-
03-72 for additional information on
ST 3000 Fieldbus transmitters.
In Asia:
Honeywell Asia Pacific Inc.
Transmitter Configuration
(Option TC)
Honeywell Building,
17 Changi Business Park Central 1
Singapore 486073
The factory can configure the
transmitter linear/square root
extraction, damping time, LRV,
URV and mode (analog/digital) and
enter an ID tag of up to eight
characters and scratchpad
information as specified.
SIL2/SIL3 Certification
(Option SL)
Republic of Singapore
This ST 3000 product is available
for use with safety systems. With
the SL option, we are fully certified
to SIL 2 capability for single
transmitters and SIL 3 capability for
multiple transmitter use through
TÜV Nord Sys Tec GmbH & Co.
KG. We are in compliance with the
following SIL standards:
In the Pacific:
Honeywell Pty Ltd.
5 Thomas Holt Drive
North Ryde NSW Australia 2113
(61 2) 9353 7000
Custom Calibration and ID in
Memory (Option CC)
In Japan:
The factory can calibrate any range
within the scope of the transmitter’s
range and enter an ID tag of up to
eight characters in the transmitter’s
memory.
Honeywell K.K.
14-6 Shibaura 1-chrome
Minato-ku, Tokyo, Japan 105-0023
IEC 61508-1: 1998;
IEC 61508-2: 2000;
IEC 61508-3: 1998
Or, visit Honeywell on the World Wide
Web at: http://www.honeywell.com
Specifications are subject to change
without notice
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 20
Model Selection Guide (34-ST-16-32)
Model Selection Guide
34-ST-16-32 Issue 39
Instructions
●
●
●
●
●
Select the desired Key Number. The arrow to the right marks the selection available.
Make one selection from each Table I and II using the column below the proper arrow.
Select as many Table III options as desired (if no options or approvals are desired, specify 9X).
A (●) denotes unrestricted availability. A letter denotes restricted availability.
Restrictions follow Table IV.
I
II
III (Optional)
IV
Key Number
_ _ _ _ _ _
_ _ _
_ _ _ _ _ _ _ _ _ _ _ _
_ _ , _ _
XXXX
-
-
-
+
KEY NUMBER
Availability
Description
Selection
0-10" to 0-400" H2O/0-25 to 0-1,000 mbar
Body Rating*: 2,500 psi (172 bar) Compound Characterized
0-5 to 0-100 psi/0-0.34 to 0-7 bar
STR12D
STR13D
STR14A
STR14G
STR17G
Body Rating*: 2,500 psi (172 bar)
0-5 to 0-500 psia/0-0.34 to 0-35 bar
Body Rating*: 500 psi (35 bar)
0-5 to 0-500 psi/0-0.34 bar to 0-35 bar
Body Rating*: 500 psi (35 bar)
0-100 to 0-3,000 psi/0-7 bar to 210 bar
Body Rating*: 3,000 psi (210 bar)
* Remote seal system pressure rating is body rating or seal rating, whichever is less.
Base STR models no longer include a default communications option. All units now require the
selection of a communication option from Table III (AN, DE, HC, H6 or FF).
Important Note:
TABLE I - METER BODY
Selection
1 Remote Seal (High Side)
2 Remote Seals
1 Remote Seal (Low Side)
Value Added Model (VAM unit)
Silicone (DC 200)
1 _ _
2 _ _
3 _ _
5 _ _
_ 1 _
_ 2 _
●
●
●
8
●
q
●
●
Number of Seals
8
●
q
8
●
q
Fill Fluid
(Meter body)
Construction
CTFE
Non-Wetted Adapter Head Material
316 SS Bonnet
_ _ A
_ _ D
_ _ A
_ _ D
_ _ C
_ _ A
_ _ D
●
y
In-Line Gauge
316 SS Bonnet for Close-Couple
316 SS (bolt-on heads)
316 SS for Close-Couple
316 SS with all-welded meter body
316 SS Adapter Head
●
y
7
Dual Head DP
Single Head
Absolute
●
y
316 SS Head for Close-Couple
Dual Head DP
In-Line Gauge
All welded
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 21
TABLE II - SEALS
Format for Seal Selection:
Specify 12 characters
14A
_ _ _ _ _ _ _ _ _ _ _ _
Common Required Seal
12D & 13D
Selection
14G&17G
Note: The first 3 characters are common to all seals.
When selecting required seal, you must specify
only the 9 selections within the required seal.
No Fill Fluid
0 _ _ _ _ _ _ _ _ _ _ _
1 _ _ _ _ _ _ _ _ _ _ _
2 _ _ _ _ _ _ _ _ _ _ _
3 _ _ _ _ _ _ _ _ _ _ _
4 _ _ _ _ _ _ _ _ _ _ _
5 _ _ _ _ _ _ _ _ _ _ _
_ 0 _ _ _ _ _ _ _ _ _ _
_ A _ _ _ _ _ _ _ _ _ _
_ B _ _ _ _ _ _ _ _ _ _
_ C _ _ _ _ _ _ _ _ _ _
_ D _ _ _ _ _ _ _ _ _ _
_ E _ _ _ _ _ _ _ _ _ _
_ F _ _ _ _ _ _ _ _ _ _
_ G _ _ _ _ _ _ _ _ _ _
_ H _ _ _ _ _ _ _ _ _ _
_ J _ _ _ _ _ _ _ _ _ _
_ K _ _ _ _ _ _ _ _ _ _
_ L _ _ _ _ _ _ _ _ _ _
_ M _ _ _ _ _ _ _ _ _ _
_ 2 _ _ _ _ _ _ _ _ _ _
_ _ 0 _ _ _ _ _ _ _ _ _
_ _ _ 0 0 0 0 0 0 0 0 0
3
●
●
●
●
●
3
●
●
●
●
●
●
●
●
●
●
●
●
z
3
●
●
●
●
●
3
●
●
●
●
●
●
●
●
●
●
●
●
z
3
●
●
●
●
●
3
●
●
●
●
●
●
●
●
●
●
●
●
z
Silicone (DC 200)
CTFE
Secondary Fill
Silicone (DC 704)
Neobee(M20) **
Syltherm 800 ***
No Capillary, No Nipple
5 feet
10 feet
15 feet
20 feet
25 feet
35 feet
5 feet
10 feet
15 feet
20 feet
25 feet
35 feet
1.5 m
3.0 m
4.5 m
6.1 m
7.5 m
10.7 m
1.5 m
3.0 m
4.5 m
6.1 m
7.5 m
10.7 m
SS Armor
Connection of
Remote Seal to
Meter Body
Capillary
Length
PVC Coated SS
Armor
2 inch long SS nipple close-coupled
No Selection
●
3
●
3
●
3
No Seal Attached to Core Transmitter
Flange
Size
Flange Pressure
Diaphragm
Diameter
Selection
Rating *
ANSI Class 150
ANSI Class 300
DIN DN80-PN40
_ _ _ AFA _ _ _ _ _ _
_ _ _ AFC _ _ _ _ _ _
_ _ _ AFM _ _ _ _ _ _
Selection
●
●
●
●
●
●
●
●
●
3.5"
3"
Diaphragm
Upper Insert
316 SS
316L SS
Hastelloy C
Hastelloy C
Monel
_ _ _ _ _ _ AA _ _ _ _
_ _ _ _ _ _ AB _ _ _ _
_ _ _ _ _ _ AC _ _ _ _
_ _ _ _ _ _ AE _ _ _ _
●
●
●
●
1
●
●
●
9
●
5
5
●
●
●
●
1
●
●
●
9
●
5
5
●
●
●
●
1
●
●
●
9
●
5
5
316 SS
Wetted Material
Hastelloy C
Monel
Flush Flanged
Seal
Tantalum
316 SS
_ _ _ _ _ _ AF _ _ _ _
_ _ _ _ _ _ _ _ 1 _ _ _
_ _ _ _ _ _ _ _ 2 _ _ _
_ _ _ _ _ _ _ _ _ 1 _ _
_ _ _ _ _ _ _ _ _ 2 _ _
_ _ _ _ _ _ _ _ _ _ A _
_ _ _ _ _ _ _ _ _ _ B _
_ _ _ _ _ _ _ _ _ _ C _
CS (Nickel Plated)
Non-Wetted Material
(upper)
316 SS
Center Seal
Side Seal
None
Seal-Capillary
Connection
Calibration Rings
316 SS
Hastelloy C
Monel
_ _ _ _ _ _ _ _ _ _ D _
5
5
5
Table II continued next page
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 22
STR14A
14G & 17G
STR12D & 13D
Selection
TABLE II - SEALS (continued)
Flushing
None
_ _ _ _ _ _ _ _ _ _ _ 0
_ _ _ _ _ _ _ _ _ _ _ H
_ _ _ _ _ _ _ _ _ _ _ J
_ _ _ _ _ _ _ _ _ _ _ M
_ _ _ _ _ _ _ _ _ _ _ N
_ _ _ _ _ _ _ _ _ _ _ P
_ _ _ _ _ _ _ _ _ _ _ Q
_ _ _ _ _ _ _ _ _ _ _ R
_ _ _ _ _ _ _ _ _ _ _ S
●
6
6
6
6
6
6
6
6
●
6
6
6
6
6
6
6
6
●
Flush Flanged
Seal
Connections
One 1/4" with plastic plug
One 1/4" with metal plug
Two 1/4" with plastic plugs
Two 1/4" with metal plugs
One 1/2" with plastic plug
One 1/2" with metal plug
Two 1/2" with plastic plugs
Two 1/2" with metal plugs
6
6
6
6
6
6
6
6
and Plugs****
(Metal plug material
will be the same as
Cal. ring material if
metal plug is chosen -
SS Plug for CS Lower)
Table II continued below
Standard facing 125-250 AARH RF (raised face) serrated surface finish.
Limited vacuum availability.
*
**
Minimum static pressure requirement. No vacuum allowed. See Specifications Figure 15.
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
Tantalum Upper insert has Tantalum wetted parts and 316 SS or CS non-wetted parts
***
****
a
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
STR12D & 13D
Selection
STR14A
14G & 17G
TABLE II - SEALS (continued)
Flange
Pressure
Rating *
Const. - See
Spec. Figure 34-
ST-03-64
Flange
Size
Construction - See Spec.
Figure 34-ST-03-64
Diaphragm
Diameter
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 300
ANSI 150
ANSI 300
22
22
22
22
22
22
22
22
23
23
23
22
22
22
22
22
23
23
23
23
23
22
22
22
_ _ _ BCA _ _ _ _ _ _
_ _ _ BCC _ _ _ _ _ _
_ _ _ BGA _ _ _ _ _ _
_ _ _ BGC _ _ _ _ _ _
_ _ _ BDA _ _ _ _ _ _
_ _ _ BDC _ _ _ _ _ _
_ _ _ BFA _ _ _ _ _ _
_ _ _ BFC _ _ _ _ _ _
_ _ _ CAA _ _ _ _ _ _
_ _ _ CCA _ _ _ _ _ _
_ _ _ CCC _ _ _ _ _ _
_ _ _ CGA _ _ _ _ _ _
_ _ _ CGC _ _ _ _ _ _
_ _ _ CDA _ _ _ _ _ _
_ _ _ CDC _ _ _ _ _ _
_ _ _ DAA _ _ _ _ _ _
_ _ _ DCA _ _ _ _ _ _
_ _ _ DCC _ _ _ _ _ _
_ _ _ DGA _ _ _ _ _ _
_ _ _ DGC _ _ _ _ _ _
_ _ _ DDA _ _ _ _ _ _
_ _ _ DDC _ _ _ _ _ _
_ _ _ DFA _ _ _ _ _ _
_ _ _ DFC _ _ _ _ _ _
t
4
4
4
4
4
4
4
4
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
1"
1-1/2"
2"
t
t
t
2.4"
t
t
t
t
3"
1/2"
1"
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Flush Flanged
2.9"
1-1/2"
Seal with Lower
2"
1/2"
1"
1-1/2"
2"
4.1"
3"
Table II continued next page
*
Standard facing 125-250 AARH RF (raised face) serrated finish.
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
**
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 23
STR14A
14G & 17G
STR12D & 13D
TABLE II - SEALS (continued)
Diaphragm
316L SS
Hastelloy C
Hastelloy C
Monel
Tantalum
Tantalum
Tantalum
Upper
Lower
316 SS
316 SS
Hastelloy C
Monel
316 SS
Hastelloy C
Tantalum Clad
Upper Insert
316 SS
Selection
_ _ _ _ _ _ BA _ _ _ _
_ _ _ _ _ _ BB _ _ _ _
_ _ _ _ _ _ BC _ _ _ _
_ _ _ _ _ _ BE _ _ _ _
_ _ _ _ _ _ BF _ _ _ _
_ _ _ _ _ _ BG _ _ _ _
_ _ _ _ _ _ BH _ _ _ _
Selection
●
●
●
●
1
1
●
●
●
●
1
1
●
●
●
●
1
1
Wetted Material
10 10 10
Non-Wetted Material
(upper, upper insert)
316 SS
_ _ _ _ _ _ _ _ 4 _ _ _
_ _ _ _ _ _ _ _ 5 _ _ _
●
●
●
●
●
●
Carbon Steel
316 SS
Bolts***
No Selection
_ _ _ _ _ _ _ _ _ 0 _ _
_ _ _ _ _ _ _ _ _ _ 0 _
_ _ _ _ _ _ _ _ _ _ H _
_ _ _ _ _ _ _ _ _ _ J _
_ _ _ _ _ _ _ _ _ _ M _
_ _ _ _ _ _ _ _ _ _ N _
_ _ _ _ _ _ _ _ _ _ P _
_ _ _ _ _ _ _ _ _ _ Q _
_ _ _ _ _ _ _ _ _ _ R _
_ _ _ _ _ _ _ _ _ _ S _
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
None
One 1/4" with plastic plug
One 1/4" with metal plug
Two 1/4" with plastic plugs
Two 1/4" with metal plugs
One 1/2" with plastic plug
One 1/2" with metal plug
Two 1/2" with plastic plugs
Two 1/2" with metal plugs
Klinger C-4401
Flushing
Connections
and Plugs**
(Metal plug material
will be the same as
Lower material, if
metal plug is chosen -
(SS Plug for CS Lower
and Tantalum Clad)
Flush Flanged
Seal with Lower
_ _ _ _ _ _ _ _ _ _ _ K
c
c
c
(non-asbestos)
Grafoil
Teflon
Gylon 3510
_ _ _ _ _ _ _ _ _ _ _ G
_ _ _ _ _ _ _ _ _ _ _ T
_ _ _ _ _ _ _ _ _ _ _ L
●
c
d
●
c
d
●
c
d
Gasket
Standard facing 125-250 AARH RF (raised face) serrated finish.
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
Bolt material will be same as Upper Material. However, if Table III bolt/nut option is chosen, seal bolt material will be the same.
Table II continued below
*
**
***
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
STR14A
14G & 17G
STR12D & 13D
Selection
TABLE II - SEALS (continued)
Flange
Size
Diaphragm
Diameter
Flange Pressure Rating *
ANSI Class 150
ANSI Class 300
DIN DN80-PN40
ANSI Class 150
ANSI Class 300
DIN DN100-PN40
3"
_ _ _ EFA _ _ _ _ _ _
_ _ _ EFC _ _ _ _ _ _
_ _ _ EFM _ _ _ _ _ _
_ _ _ FGA _ _ _ _ _ _
_ _ _ FGC _ _ _ _ _ _
_ _ _ FGP _ _ _ _ _ _
Selection
_ _ _ _ _ _ EA _ _ _ _
_ _ _ _ _ _ EB _ _ _ _
_ _ _ _ _ _ EC _ _ _ _
_ _ _ _ _ _ _ _ 7 _ _ _
_ _ _ _ _ _ _ _ 8 _ _ _
_ _ _ _ _ _ _ _ _ 0 _ _
_ _ _ _ _ _ _ _ _ _ 2 _
_ _ _ _ _ _ _ _ _ _ 4 _
_ _ _ _ _ _ _ _ _ _ 6 _
●
●
●
●
●
●
●
●
●
●
●
●
●
(2.8" OD
extension)
4"
2.8"
3.5"
●
●
●
●
●
(3.70" OD
extension
Diaphragm
316L SS
Ext. Tube
316 SS
Flange Seal
with Extended
Diaphragm
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
Wetted Material
Hastelloy C
Hastelloy C
316 SS
Hastelloy C
Non-Wetted
Material (flange)
Bolts
CS (Nickel Plated)
316 SS
No Selection
2"
4"
6"
Extension Length
No Selection
No Selection
No Selection
_ _ _ _ _ _ _ _ _ _ _ 0
●
●
●
Table II continued next page
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 24
STR14A
14G & 17G
STR12D & 13D
Selection
TABLE II - SEALS (continued)
Flange
Flange Pressure Rating
Dependent on Customer Flange
Diaphragm
Diameter
Size
ANSI Class 150/300/600
3.5"
3"
_ _ _ GFA _ _ _ _ _ _
●
●
●
Diaphragm
316L SS
Body
316 SS
_ _ _ _ _ _ GA _ _ _ _
_ _ _ _ _ _ GB _ _ _ _
_ _ _ _ _ _ GC _ _ _ _
_ _ _ _ _ _ GE _ _ _ _
_ _ _ _ _ _ GG _ _ _ _
●
●
●
●
1
●
●
●
●
1
●
●
●
●
1
Hastelloy C
Hastelloy C
Monel
316 SS
Wetted Material
Hastelloy C
Monel
Tantaluma
Tantalum
Non-Wetted Material
Bolts
No Selection
_ _ _ _ _ _ _ _ 0 _ _ _
_ _ _ _ _ _ _ _ _ 0 _ _
_ _ _ _ _ _ _ _ _ _ A _
_ _ _ _ _ _ _ _ _ _ B _
_ _ _ _ _ _ _ _ _ _ C _
_ _ _ _ _ _ _ _ _ _ D _
_ _ _ _ _ _ _ _ _ _ _ 0
_ _ _ _ _ _ _ _ _ _ _ H
_ _ _ _ _ _ _ _ _ _ _ J
_ _ _ _ _ _ _ _ _ _ _ M
_ _ _ _ _ _ _ _ _ _ _ N
_ _ _ _ _ _ _ _ _ _ _ P
_ _ _ _ _ _ _ _ _ _ _ Q
_ _ _ _ _ _ _ _ _ _ _ R
_ _ _ _ _ _ _ _ _ _ _ S
●
●
●
5
5
5
●
6
6
6
6
6
6
6
6
●
●
●
5
5
5
●
6
6
6
6
6
6
6
6
●
●
●
5
5
5
●
6
6
6
6
6
6
6
6
No Selection
None
Calibration Rings
316 SS
Hastelloy C
Pancake Seal
Monel
Flushing
None
Connections
One 1/4" with plastic plug
One 1/4" with metal plug
Two 1/4" with plastic plugs
Two 1/4" with metal plugs
One 1/2" with plastic plug
One 1/2" with metal plug
Two 1/2" with plastic plugs
Two 1/2" with metal plugs
and Plugs***
(Metal plug material
will be the same as
Cal. Ring material, if
metal plug is chosen -
SS Plug for CS Lower)
Table II continued below
Standard facing 125-250 AARH RF (raised face) serrated finish.
*
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
Tantalum Body has Tantalum wetted parts and 316 SS non-wetted parts
***
a
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
STR14A
STR12D & 13D
Selection
14G & 17G
TABLE II - SEALS (continued)
Flange
Size
Diaphragm
Diameter
Flange Pressure Rating *
Taylor
Wedge 5"
O.D.
Chemical Tee
"Taylor" Wedge
3.5"
750 psi
_ _ _ HM0 _ _ _ _ _ _
v
Diaphragm
316L SS
Hastelloy C
Hastelloy C
Body
316 SS
316 SS
Selection
_ _ _ _ _ _ HA _ _ _ _
_ _ _ _ _ _ HB _ _ _ _
_ _ _ _ _ _ HC _ _ _ _
_ _ _ _ _ _ _ _ 0 _ _ _
_ _ _ _ _ _ _ _ _ 0 _ _
_ _ _ _ _ _ _ _ _ _ 0 _
_ _ _ _ _ _ _ _ _ _ _ 0
●
●
Wetted Material
Hastelloy C
●
Non-Wetted Material
Bolts
No Selection
●
●
No Selection
No Selection
No Selection
Styles
●
No Selection
●
Table II continued next page
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 25
STR14A
14G & 17G
TABLE II - SEALS (continued)
Pressure Rating
Threaded Process
Connection Size
(NPT Female)
STR12D & 13D
Selection
Diaphragm
Diameter
304 SS
CS Bolts
Bolts
1/2" NPT
3/4" NPT
1" NPT
_ _ _ JJG _ _ _ _ _ _
_ _ _ JKG _ _ _ _ _ _
_ _ _ JLG _ _ _ _ _ _
_ _ _ KJG _ _ _ _ _ _
_ _ _ KKG _ _ _ _ _ _
_ _ _ KLG _ _ _ _ _ _
_ _ _ LJG _ _ _ _ _ _
_ _ _ LKG _ _ _ _ _ _
_ _ _ LLG _ _ _ _ _ _
Selection
t
4
4
4
●
●
●
●
●
●
●
1250
2500 psi
psi
2.4"
2.9"
4.1"
t
●
●
●
●
●
●
●
●
t
1/2" NPT
3/4" NPT
1" NPT
●
●
●
●
●
●
1250
2500 psi
psi
1/2" NPT
3/4" NPT
1" NPT
1500 psi 750 psi
Diaphragm
316L SS
316L SS
Hastelloy C
Lower
Carbon Steel
316 SS
_ _ _ _ _ _ JA _ _ _ _
_ _ _ _ _ _ JB _ _ _ _
_ _ _ _ _ _ JC _ _ _ _
_ _ _ _ _ _ JD _ _ _ _
_ _ _ _ _ _ JE _ _ _ _
_ _ _ _ _ _ JF _ _ _ _
_ _ _ _ _ _ JG _ _ _ _
_ _ _ _ _ _ _ _ A _ _ _
_ _ _ _ _ _ _ _ C _ _ _
_ _ _ _ _ _ _ _ _ C _ _
_ _ _ _ _ _ _ _ _ D _ _
_ _ _ _ _ _ _ _ _ _ 0 _
_ _ _ _ _ _ _ _ _ _ H _
_ _ _ _ _ _ _ _ _ _ J _
_ _ _ _ _ _ _ _ _ _ M _
_ _ _ _ _ _ _ _ _ _ N _
_ _ _ _ _ _ _ _ _ _ P _
_ _ _ _ _ _ _ _ _ _ Q _
_ _ _ _ _ _ _ _ _ _ R _
_ _ _ _ _ _ _ _ _ _ S _
●
●
●
●
●
1
●
●
●
●
●
1
1
●
w
1
●
●
●
●
●
●
●
●
●
●
●
1
316 SS
Wetted Material
Hastelloy C
Monel
316 SS
Hastelloy C
Monel
Tantalum
Tantalum
Seal with
Threaded
Process
Hastelloy C
1
1
CS (Nickel Plated)
●
w
1
●
w
1
Non-Wetted Material
(upper)
Stainless Steel
Carbon Steel
Connection
Bolts*
304 SS
●
●
●
●
●
●
●
●
●
●
●
●
Flushing
None
Connections
One 1/4" with plastic plug
One 1/4" with metal plug
Two 1/4" with plastic plugs
Two 1/4" with metal plugs
One 1/2" with plastic plug
One 1/2" with metal plug
Two 1/2" with plastic plugs
Two 1/2" with metal plugs
Klinger C-4401
and Plugs**
(Metal plug material
will be the same as
Lower material, if
metal plug is chosen -
(SS Plug for CS Lower
and Tantalum Clad)
11 11 11
11 11 11
11 11 11
11 11 11
_ _ _ _ _ _ _ _ _ _ _ K
c
c
c
(non-asbestos)
Grafoil
Gasket
_ _ _ _ _ _ _ _ _ _ _ G
_ _ _ _ _ _ _ _ _ _ _ T
_ _ _ _ _ _ _ _ _ _ _ L
●
c
d
●
c
d
●
c
d
Teflon
Gylon 3510
Table II continued next page
*
If Table III Bolt/Nut option is chosen, Seal bolts will ship as same material, and MAWP may change.
Plastic Plugs are TEMPORARY ONLY to protect threads and MUST be REMOVED before installation
**
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 26
STR14A
14G & 17G
STR12D & 13D
Selection
TABLE II - SEALS (continued)
Diaphragm
Flange
Pressure Rating
Diameter
Size
1.9"
2.4"
2.9"
4.1"
2"
_ _ _ MD0 _ _ _ _ _ _
_ _ _ NE0 _ _ _ _ _ _
_ _ _ PF0 _ _ _ _ _ _
_ _ _ QG0 _ _ _ _ _ _
Selection
●
●
●
●
2-1/2"
3"
t
Customer clamp rating or 600
psi, whichever is less
●
●
●
●
4"
Diaphragm
Body
Wetted Material
316L SS
316 SS
_ _ _ _ _ _ N A _ _ _ _
●
●
●
●
Sanitary Seal
Non-Wetted Material
No Selection
_ _ _ _ _ _ _ _ 0 _ _ _
●
●
Bolts
Styles
Gasket
No Selection
_ _ _ _ _ _ _ _ _ 0 _ _
_ _ _ _ _ _ _ _ _ _ 8 _
_ _ _ _ _ _ _ _ _ _ _ 0
●
●
●
●
●
●
●
●
●
Tri-Clover Tri-Clamp
No Selection
Size and
Diaphragm
Bolt
Seal Pressure Rating * *
Selection
Diameter
C.S. Bolts
304 SS Bolts
Pattern
2.4"
_ _ _ RFK _ _ _ _ _ _
_ _ _ RGK _ _ _ _ _ _
_ _ _ RPK _ _ _ _ _ _
t
t
t
t
4
4
4
4
●
●
●
●
for 3" Pipe
8-Bolt
1500 psi
1500 psi
≥ 4" pipe
Design
2.4"
for 3" Pipe
6-Bolt
1250 psi
1250 psi
≥ 4" pipe
_ _ _ RQK _ _ _ _ _ _
Selection
Design
Diaphragm
Lower Housing
Carbon Steel
316 SS
316L SS
_ _ _ _ _ _ RA _ _ _ _
_ _ _ _ _ _ RB _ _ _ _
_ _ _ _ _ _ RC _ _ _ _
_ _ _ _ _ _ RD _ _ _ _
_ _ _ _ _ _ SB _ _ _ _
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
316L SS
Hastelloy C
Hastelloy C
316L SS
316 SS
Wetted Material
Hastelloy C
N/A-Body Only
N/A-Body Only
Bolts *, ***
Saddle Seal
Hastelloy C
_ _ _ _ _ _ SC _ _ _ _
Selection
Body
Carbon Steel Carbon Steel
316 SS 304 SS
No Selection
No Selection
Klinger C-4401
(non-asbestos)
Grafoil
_ _ _ _ _ _ _ _ B _ _ _
1
●
●
●
1
●
●
●
1
●
●
●
Non-Wetted Material
_ _ _ _ _ _ _ _ C _ _ _
_ _ _ _ _ _ _ _ _ 0 _ _
_ _ _ _ _ _ _ _ _ _ 0 _
Bolts
Styles
_ _ _ _ _ _ _ _ _ _ _ K
●
●
●
Gasket
_ _ _ _ _ _ _ _ _ _ _ G
_ _ _ _ _ _ _ _ _ _ _ T
_ _ _ _ _ _ _ _ _ _ _ L
●
●
●
●
●
●
●
●
●
Teflon
Gylon 3510
Note: All sanitary seals have dairy grade 3A approval.
Note: Remote seal system pressure rating is body rating or seal rating, whichever is less.
*
If a Table III Bolt/Nut option is chosen, Seal bolts will ship as same material, and MAWP may change.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 27
STR14A
STR12D & 13D
14G & 17G
TABLE III - OPTIONS
Communication Options (Must choose a communications option)
Analog only (can be configured using appropriate Honeywell DE tool)
DE Protocol communications
HART 5.x Protocol compatible electronics
HART 6.x Protocol compatible electronics
AN
DE
HC
H6
FF
●
●
e
e
r
●
●
e
e
r
●
●
e
e
r
b
FOUNDATION Fieldbus Communications
Indicating Meter Options
Analog Meter (0-100 Even 0-10 Square Root)
Smart Meter
ME
SM
CI
●
●
f
●
●
f
●
b
●
f
Custom Configuration of Smart Meter
Local Zero & Span
Local Zero
ZS
LZ
m
x
m
x
b
Transmitter Housing & Electronics Options
NAMUR Failsafe Software
SIL 2 - TÜV Certified transmitter (requires HC or H6 and WP options)
Lightning Protection
Custom Calibration and I.D. in Memory
Transmitter Configuration - (non-Fieldbus)
15 15 15
14 14 14
NE
SL
LP
CC
TC
FC
WP
WX
SH
A1
●
●
●
●
●
●
15 15 15
21 21 21
Transmitter Configuration - (Fieldbus)
Write Protection (Delivered in the "enabled" position)
Write Protection (Delivered in the "disabled" position)
316 SS Electronics Housing - with M20 Conduit Connections
1/2" NPT to M20 316 SS Conduit Adapter (BASEEFA EEx d IIC)
1/2" NPT to 3/4" NPT 316 SS Conduit Adapter
Stainless Steel Housing with M20 to 1/2" NPT 316 SS Conduit
Adapter (use for FM and CSA Approvals)
●
●
n
n
u
●
●
n
n
u
●
●
n
n
u
b
b
A2
A3
i
i
i
Stainless Steel Customer Wired-On Tag
TG
●
●
●
b
(4 lines, 28 characters per line, customer supplied information)
Stainless Steel Customer Wired-On Tag (blank)
End Cap Live Circuit Warning Label in Spanish (only with ATEX 3D)
End Cap Live Circuit Warning Label in Portuguese (only with ATEX 3D)
End Cap Live Circuit Warning Label in Italian (only with ATEX 3D)
End Cap Live Circuit Warning Label in German (only with ATEX 3D)
Meter Body Options (Seal bolt material depends on Transmitter bolt material)
A286 SS (NACE) Bolts and 304 SS (NACE) Nuts for Heads
316 SS Bolts and 316 SS Nuts for Process Heads
B7M Bolts and Nuts for Process Heads
TB
SP
PG
TL
●
a
a
a
a
●
a
a
a
a
●
a
a
a
a
b
GE
CR
SS
B7
●
●
●
●
b
Remote Seal Options
Gold Plated Seal Diaphragm (1 Seal)
G1
G2
N1
N2
j
j
j
j
j
j
j
j
Gold Plated Seal Diaphragm (2 Seals)
Teflon Coated Seal Diaphragm (1 Seal) - only for anti-sticking
Teflon Coated Seal Diaphragms(2 Seals) - only for anti-sticking
Transmitter Mounting Brackets Options
Mounting Bracket - Carbon Steel
Mounting Bracket - 304 SS
Flat Mounting Bracket
b
b
MB
SB
FB
●
●
●
●
●
●
●
●
●
Services/Certificates Options
UM
0X
TP
F1
F3
F5
F6
FE
F7
FG
F8
MT
Users Manual Paper Copy (Standard, HC/H6 or FF ships accordingly)
Clean Transmitter for Oxygen or Chlorine Service with Certificate
Over-Pressure Leak Test with F3392 Certificate
Calibration Test Report and Certificate of Conformance (F3399)
Certificate of Conformance (F3391)
Certificate of Origin (F0195)
FMEDA Certificate (SIL 1) (FC33321)
SIL Certificate (SIL 2/3) (FC33337)
NACE Certificate (Process-Wetted & Non-Process Wetted) (FC33339)
NACE Certificate (Process-Wetted only) (FC33338)
NACE Certificate (F0198) for all welded meter bodies only
Marine Type Approvals (DNV, ABS, BV, KR & LR)
●
h
●
●
●
●
●
●
h
●
●
●
●
●
●
h
●
●
●
●
●
b
b
22 22 22
●
o
16
2
●
o
●
●
b
2
2
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 28
STR14A
14G & 17G
STR12D & 13D
TABLE III - OPTIONS (continued)
Warranty Options
Additional Warranty - 1 year
Additional Warranty - 2 years
Additional Warranty - 3 years
Additional Warranty - 4 years
W1
W2
W3
W4
●
●
●
●
●
●
●
●
●
●
●
●
b
Approval
Approval Type
Body
Location or Classification
Selection
No hazardous location approvals
Explosion Proof
9X
●
●
●
●
●
●
Class I, Div. 1, Groups A,B,C,D
Class II, III Div. 1, Groups E,F,G
Class I, Div. 2, Groups A,B,C,D
Class I, II, III, Div. 1, Groups
A,B,C,D,E,F,G
Dust Ignition Proof
Factory
Non-Incendive
Mutual
1C
2J
Intrinsically Safe
Explosion Proof
Class I, Div. 1, Groups B,C,D
Class II, III, Div. 1, Groups E,F,G
Class I, II, III, Div. 1, Groups
A,B,C,D,E,F,G
Dust Ignition Proof
CSA
●
●
●
Intrinsically Safe
Intrinsically Safe
Non-Sparking
Intrinsically Safe,
Zone 0/1
Ex ia IIC T4
SA
(Australia)
4G
3S
3D
3N
●
●
●
●
●
●
●
●
●
●
●
●
Ex n IIC T6 (T4 with SM option)
EEx ia IIC T4, T5,T6
b
EEx d IIC T5, T6,
Enclosure IP 66/67
Flameproof, Zone 1
Non-Sparking, Zone 2
EEx nA, IIC T6
ATEX*
(Honeywell). Enclosure IP 66/67
Ex II 1 G EEx ia IIC T4, T5, T6
Ex II 2 G EEx d IIC T5, T6
Multiple Marking**
Int. Safe, Zone 0/1, or
3H
6D
●
●
●
●
●
●
Flameproof, Zone 1, or Ex II 3 G EEx nA, IIC T6 (Honeywell)
Non-Sparking, Zone 2
Enclosure IP 66/67
INMETRO
(Brazil)
Flameproof, Zone 1
Ex d IIC T5
*See ATEX installation requirements in the ST 3000 User's Manual
**The user must determine the type of protection required for installation of the equipment. The user shall
then check the box [√] adjacent to the type of protection used on the equipment certification nameplate.
Once a type of protection has been checked on the nameplate, subsequently the equipment shall not be
reinstalled using any of the other certification types.
TABLE IV
Factory Identification
XXXX
●
●
●
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 29
RESTRICTIONS
Restriction
Available Only With
Selection
Not Available With
Selection
Letter
Table
Table
a
b
III
3D or 3H
Select only one option from this group
II
_ _ _ _ _ _ BF _ _ _ _,
_ _ _ _ _ _ BG _ _ _ _,
_ _ _ _ _ _ JF _ _ _ _,
_ _ _ _ _ _ JG _ _ _ _,
c
d
_ _ _ _ _ _ BF _ _ _ _,
_ _ _ _ _ _ BG _ _ _ _,
_ _ _ _ _ _ BH _ _ _ _,
_ _ _ _ _ _ JF _ _ _ _,
_ _ _ _ _ _ JG _ _ _ _,
II
III
e
f
4G
III
I, II
III
SM
h
i
_ 2 _ - 2 _ _ _ _ _ _ _ _ _ _ _
1C or 2J
_ _ _ _ _ _ AF _ _ _ _
_ _ _ _ _ _ BF _ _ _ _
_ _ _ _ _ _ BG _ _ _ _
_ _ _ _ _ _ BH _ _ _ _
_ _ _ _ _ _ GG _ _ _ _
_ _ _ _ _ _ JF _ _ _ _
_ _ _ _ _ _ JG _ _ _ _
j
II
III
III
m
n
ME, FF
1C, 2J
III
II
o
CR
0 _ _ _ _ _ _ _ _ _ _ _,
2 _ _ _ _ _ _ _ _ _ _ _
4 _ _ _ _ _ _ _ _ _ _ _
q
III
r
TC, ME, 4G, 3S
s
Must be specified with Model STR12D
2 _ _ - _ B _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ C _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ D _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ E _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ F _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ H _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ J _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ K _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ L _ _ _ _ _ _ _ _ _ _,
2 _ _ - _ M _ _ _ _ _ _ _ _ _ _
t
I & II
cont’d
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 30
RESTRICTIONS (continued)
Restriction
Available Only With
Selection
1C, 2J
Not Available With
Selection
Letter
u
v
Table
III
Table
I
2 _ _
II
w
x
_ _ _ _ _ _ JA _ _ _ _
III
FF, SM
I
2 _ _
III
MB, SB, FB
y
II
I
_ 2 _ _ _ _ _ _ _ _ _ _
_ _ D
z
1
2
3
III
III
F7
FB
I
5 _ _
See Figure 23 in Specification
_ A _ _ _ _ _ _ _ _ _ _,
_ G _ _ _ _ _ _ _ _ _ _,
_ B _ _ _ _ _ _ _ _ _ _,
_ H _ _ _ _ _ _ _ _ _ _,
_ 2 _ _ _ _ _ _ _ _ _ _,
4
II
II
II
I
_ _ _ _ _ _ _ _ _ _ _ 0
_ _ _ _ _ _ _ _ _ _ A _
1 _ _, 3 _ _
5
6
7
III
CR
CC, G1, G2, N1, N2, OX, TP, MT, TC,
FC, F1,
III
8
9
_ _ _ _ _ _ AA2_ _ _
_ _ _ _ _ _ AB2_ _ _
II
II
II
III
_ _ _ _ _ _ _ _ _ _ _ T
F7
10
_ _ _ _ _ _ _ _ _ _ 0 _
_ _ _ _ _ _JJG_ _ _
_ _ _ _ _ _JKG_ _ _
_ _ _ _ _ _JLG_ _ _
_ _ _ _ _ _CAA_ _ _
_ _ _ _ _ _CCA_ _ _
_ _ _ _ _ _CCC_ _ _
FF, 00
11
II
III
HC or H6 and WP
III
III
14
15
16
21
22
FF
I
III
III
_ _ C
FF
SL
See ST-83 for Published Specials with pricing.
See ST-89 and User's Manual for part numbers.
Note:
See COMS Order Entry Information including TC, manuals, certificates, drawings and SPINS.
See ST-OD-1 for tagging, ID, Transmitter Configuration (TC) and calibration including factory default values.
To request a quote for a non-published "special", fax RFQ w/ Application Data Sht (34-ST-18-01) to Mktg. Applications.
See Specification 34-ST-03-64 for Seal dimensions.
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 31
Dimensions and Drawings
21a
21b
21b
21a
21a
21a
21a
21b
21b
21a
21a
21a
21a
21b
21b
21a
21a
21a
21a
21b
21b
21a
21a
21a
Figure 21a. Flush Flanged Seal
Figure 21b. Flush Flanged Seal
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 32
Dimensions and Drawings, cont.
Figure 22
Figure 23
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 33
Dimensions and Drawings, cont.
Figure 24
Figure 25
Figure 26
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 34
Dimensions and Drawings, cont.
Figure 27
Figure 28
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 35
Dimensions and Drawings, cont.
Figure 29
Figure 30
Figure 31
Download from Www.Somanuals.com. All Manuals Search And Download.
34-ST-03-64
Page 36
THIS PAGE INTENTIONALLY BLANK
ST 3000® is a registered trademark of Honeywell International Inc.
HART* is a trademark of the Hart Communication Foundation.
FOUNDATION™ is a trademark of the Fieldbus Foundation.
Honeywell Field Solutions
Honeywell International Inc.
2500 W. Union Hill Drive
Phoenix, Arizona 85027
©Honeywell International Inc.
Download from Www.Somanuals.com. All Manuals Search And Download.
|