		 800-08115 1/11 Rev. B   
					GSMVLP5 GSM and   
					ILP5 Ethernet   
					Communications Modules   
					Installation and Setup Guide   
					Installing Communication Modules   
					RF Exposure   
					WARNING: The antenna(s) used for this transmitter must be installed to provide a separation distance of   
					at least 20 cm from all persons and must not be co-located or operating in conjunction with any other   
					antenna(s) or transmitter.   
					Installing the GSMVLP5 in the LYNX Touch Series Control   
					Ensure that SIM card and the connector board are securely installed in the GSMVLP5 before installing the   
					module in the LYNX Touch.   
					1. Install the provided FCC/IC label (P/N 800-08334) on the control’s case back (refer to Figure 1).   
					LYNX TOUCH SERIES   
					FCC ID: CFS-8DLLYNXTOUCH1   
					IC: 573F-LYNXTOUCH1   
					IC MODEL: LYNXTOUCHG1   
					CONTAINS TRANSMITTER MODULE   
					FCC ID: QIPMC55I   
					IC: 7830A-MC55I   
					800-08334 2/11 Rev   
					A 
					LYNX TOUCH SERIES   
					THIS DEVICE COMPLIES WITH PART 15 OF FCC RULES AND RSS 210 OF INDUSTRY   
					CANADA. OPERATION IS SUBJECT TO THE FOLLOWING TWO CONDITIONS: (1) THIS   
					DEVICE MAY NOT CAUSE HARMFUL INTERFERENCE, AND (2) THIS DEVICE MUST   
					ACCEPT ANY INTERFERENCE RECEIVED, INCLUDING INTERFERENCE THAT MAY   
					CAUSE UNDESIRED OPERATION.   
					COMPLIES WITH FCC RULES, PART 68 FCC REGISTRATION NO.: AC3AL05BL5000   
					RINGER EQUIVALENCE: 0.1B   
					800-08126 1/11 Rev   
					A 
					5000-100-186-V0   
					Figure 1. FCC/IC Label Location   
					2. Release the LYNX Touch front case from the back case by depressing the two locking tabs at the top of the   
					unit with the blade of a medium size screwdriver (Refer to Figure 2).   
					3. Install the GSMVLP5 into the LYNX Touch control front case. Ensure that the connector board is properly   
					seated into the receptacle on the control (Refer to Figure 2).   
					4. Secure the GSMVLP5 with the three provided screws (Refer to Figure 2).   
					5. Enable the GSMVLP5 device, configure alarm reporting and module supervision and register the device.   
					Refer to the “Program the Radio” and “Diagnostics” sections in the LYNX Touch Series Installation and   
					Setup Guide (P/N 800-06834 or higher).   
					For Documentation and Online Support: http://www.security.honeywell.com/hsc/resources/MyWebTech   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				ETHERNET CABLE   
					TO ILP5   
					RJ45 RECEPTACLE   
					LYNX TOUCH   
					REMOVE ILP5   
					KNOCKOUT   
					REMOVE ILP5   
					SPACER   
					ALTERNATE INSTALLATION   
					ILP5 SPACER   
					RJ45   
					RECEPTACLE   
					CONNECTOR   
					BOARD   
					ROTATED   
					TIE   
					WRAP   
					180   
					(1)   
					TIE   
					WRAP   
					POINT   
					CONNECTOR BOARD   
					SCREW   
					(3)   
					ILP5   
					RECEPTACLE   
					LYNX TOUCH   
					LOCKING TABS   
					5000-100-154-V1   
					Figure 3. Installing the ILP5 in the LYNX Touch   
					Download from Www.Somanuals.com. All Manuals Search And Download.   
				Electrical Specifications   
					GSMVLP5   
					Voltage Input   
					Current   
					Idle   
					5V   
					15 mA, standby   
					300mA, average transmit   
					1.6A peak transmit, 25% duty cycle   
					Average   
					Peak   
					ILP5   
					Voltage Input   
					Current:   
					5V   
					83 mA, 100 Base T with traffic   
					41 mA, 10 Base T with traffic   
					2 Corporate Center Drive, Suite 100   
					P.O. Box 9040, Melville, NY 11747   
					Copyright © 2011 Honeywell International Inc.   
					