ADEMCO VISTA SERIES
VISTA-21iP / VISTA-21iPSIA
Security Systems
User Guide
K14490V1 7/10 Rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents
System Overview ...................................................................................................................................... 5
Introduction ....................................................................................................................................... 5
System Basics.................................................................................................................................... 5
Using the Voice Message Center ...................................................................................................... 7
About The Keypads .................................................................................................................................. 8
General Information.......................................................................................................................... 8
Fixed-Word Display Keypad ........................................................................................................... 10
Functions of the Keypads....................................................................................................................... 11
Entry/Exit Delays................................................................................................................................... 14
Entry Delay...................................................................................................................................... 14
Exit Delay ........................................................................................................................................ 14
Exit Alarms...................................................................................................................................... 15
Checking For Open Zones ...................................................................................................................... 16
Using the [∗] Key to Display and Announce System Status.......................................................... 16
Arming the System................................................................................................................................. 17
STAY Mode: Arms Perimeter Only, Entry Delay On .................................................................... 17
NIGHT-STAY Mode: Arms Perimeter Only, Plus Selected Zones ................................................ 17
INSTANT Mode: Arms Perimeter Only, Entry Delay Off............................................................. 17
AWAY Mode: Arms Entire System, Entry Delay On..................................................................... 17
MAXIMUM Mode: Arms Entire System, Entry Delay Off ............................................................ 17
Arming Commands.......................................................................................................................... 18
Single Button Arming ..................................................................................................................... 19
Single Button “Step” Arming .......................................................................................................... 19
Keyswitch................................................................................................................................................ 20
Using the Keyswitch ....................................................................................................................... 20
Disarming and Silencing Alarms........................................................................................................... 21
Using the [OFF] key........................................................................................................................ 21
Bypassing Protection Zones ................................................................................................................... 22
Using the BYPASS Key................................................................................................................... 22
Quick Bypass ................................................................................................................................... 23
Chime Mode............................................................................................................................................ 24
Using the Chime Mode.................................................................................................................... 24
Using the Voice Chime.................................................................................................................... 24
Date and Time ........................................................................................................................................ 25
Viewing the Current Date and Time.............................................................................................. 25
Setting the Date and Time.............................................................................................................. 25
Panic Keys............................................................................................................................................... 26
Using Panic Keys............................................................................................................................. 26
– 3 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Table of Contents (continued)
Macro Key Programming & Usage ........................................................................................................ 27
About Macro Keys ........................................................................................................................... 27
Example of Macro Programming.................................................................................................... 28
Using a Programmed Macro Key.................................................................................................... 28
Using Device Commands........................................................................................................................ 29
Paging Feature ....................................................................................................................................... 30
About Automatic Paging ................................................................................................................. 30
About Manual Paging...................................................................................................................... 31
Latch Key Paging ............................................................................................................................ 31
Security Codes & Authority Levels........................................................................................................ 32
About Security Codes ...................................................................................................................... 32
Authority Level Definitions ............................................................................................................ 32
How to Assign User Codes and Attributes..................................................................................... 33
Accessing Other Partitions..................................................................................................................... 34
About Accessing Partitions ............................................................................................................. 34
Using the GoTo Command.............................................................................................................. 35
Multi-Partition Arming................................................................................................................... 35
Common Zone Operation................................................................................................................. 36
Scheduling............................................................................................................................................... 37
About Scheduling............................................................................................................................. 37
Creating Schedules.......................................................................................................................... 37
Event Logging Procedures...................................................................................................................... 39
About Event Logging....................................................................................................................... 39
Viewing the Event Log.................................................................................................................... 39
Testing the System................................................................................................................................. 41
Trouble Conditions ................................................................................................................................. 42
Maintaining Your System ...................................................................................................................... 45
Fire Alarm System ................................................................................................................................. 46
Quick Guide to Basic System Functions................................................................................................ 50
Summary of Audible/Visual Notifications............................................................................................. 51
Regulatory Statements and Warnings .................................................................................................. 53
System Features..................................................................................................................................... 55
User Setup ....................................................................................................................................... 56
Paging Setup.................................................................................................................................... 57
List of Output Devices..................................................................................................................... 58
Owner’s Insurance Premium Credit Request........................................................................................ 59
Limitations Of This System ................................................................................................................... 63
Warranty................................................................................................................................................. 64
– 4 –
Download from Www.Somanuals.com. All Manuals Search And Download.
System Overview
Introduction
Congratulations on your ownership of a Honeywell Security System. You've made a
wise decision in choosing it, for it represents the latest in security protection
technology today. This system provides:
• Three forms of protection: burglary, fire* and emergency
• At least one keypad which provides control of system and displays system status
• Various sensors for perimeter and interior burglary protection
• Smoke or combustion detectors* designed to provide early warning in case of fire.
Your system may also have been programmed to automatically send alarm or status
messages to a Central Monitoring Station.
* Commercial installations and some residential systems may not include fire
protection – check with your installer.
NOTE: Features and procedures described in this manual apply to the
VISTA-21iP/VISTA-21iPSIA security systems. Differences are noted where
applicable.
System Basics
Burglary Protection
• Several modes of burglary protection: Stay, Night-Stay, Away, Instant, Maximum.
STAY: arms perimeter zones only and entry delay is on
INSTANT: same as STAY, except entry delay is off
NIGHT-STAY: arms perimeter zones and selected interior zones; entry delay on
AWAY: arms perimeter and all interior zones, entry delay is on
MAXIMUM: same as AWAY, except entry delay is off
• You can BYPASS selected zones while leaving the rest of the system armed.
• CHIME mode alerts you to the opening of protected doors and windows while the
system is disarmed.
Fire Protection and Carbon Monoxide Protection
• Fire and carbon monoxide protection is always active (if installed) and an alarm
sounds if a fire or carbon monoxide condition is detected.
• If necessary, you can manually initiate a fire alarm using the keypad (if
programmed).
• Refer to the Fire Alarm System section for information regarding fire protection,
carbon monoxide protection, smoke detectors and planning emergency exit routes.
Security Codes
• You were assigned a 4-digit security code (master code) during installation.
• Use your security code when arming and disarming the system, and when
performing other system functions.
• Other users can be assigned different security codes, each with different
authority levels, which define the system functions a particular user can perform.
– 5 –
Download from Www.Somanuals.com. All Manuals Search And Download.
System Overview (cont’d)
Zones and Partitions
• The system sensing devices have been assigned to various “zones,” which are
specific areas of protection (e.g., front door, kitchen window, etc.).
• Zone numbers are displayed at the keypad when an alarm or trouble condition
occurs on a sensor.
• Partitions provide two independent areas of protection, with each partition
containing a group of zones that can be armed and disarmed without affecting
other zones or users.
• Partitioned systems can include a common zone area, which is an area shared by
users of both partitions (such as a lobby in a building).
Arming, Step-Arming and Disarming Burglary Protection
• The system must be armed before the burglary protection can sense intrusions.
• To arm your system, enter your user code followed by the desired arming key.
• If programmed, you can press the [#] key in place of your security code when
arming the system (e.g., instead of entering your 4-digit security code + [3-STAY]
to arm the system in STAY mode, you can press [#] + [3-STAY]).
• You can also use the step-arming feature if programmed, to arm the system. This
is a function key that allows you to arm the system in one of three modes by
simply pressing the key repeatedly.
• To disarm the system, enter your security code then press the [OFF] key.
Alarms
• When an alarm occurs, both the keypad and external sounders sound, and the
keypad displays the zone(s) causing the alarm. For most alarms, the external
sounder also sounds.
• If your system is connected to a Central Monitoring Station, an alarm message is
also sent. (Delayed Reporting Note: Message reporting is delayed 30 seconds
by default to reduce false alarms. If desired, this delay can be removed or can be
increased to 45 seconds. See your installer if you want the delay time changed.)
• To stop the alarm sounding, simply disarm the system.
Memory of Alarm
• When an alarm condition occurs, the keypad displays the number(s) of the
zone(s) that caused the problem, and displays the type of alarm.
• The message remains displayed even after disarming the system, but can be
cleared with another “off” sequence.
Phone Access
• If included, a phone module permits you to access the system via a touch-tone
phone, either on-premises or by call-in when away.
• When you call in, the phone module announces system status over the telephone,
and you can arm/disarm the system and perform most function commands
remotely using the telephone keys.
• Complete information for using these features is provided with the voice module.
– 6 –
Download from Www.Somanuals.com. All Manuals Search And Download.
System Overview (cont’d)
Function Keys
• The “A,” “B,” “C,” and “D” keys can be programmed to perform various functions.
• Functions include: activate a panic alarm, arm the system, provide step arming,
switch lights on/off, send a message to a pager, display Time/Date, and start a
programmed Macro sequence.
Paging Feature
• If programmed, the system can automatically send certain system condition
messages to up to four pagers.
• The pager displays code numbers identifying the type of condition that has occurred.
Scheduling
• Your system can be programmed to automatically perform certain functions (e.g.,
arm the system) at a predetermined time each day.
Using the Voice Message Center (if Voice Keypad is installed)
SPEAKER
LCD
Voice keypads feature a voice message
center that lets you record and playback
one message.
DISPLAY
• The message can be up to 2.5-minutes
long
ARMED
OFF
AWAY
STAY
• The message remains in memory until
1
2
3
RECORD
VOLUME
PLAY
a new message is recorded.
READY
MESSAGE
MIC
MAX
TEST
BYPASS
4
5
6
LEDs
CODE
CHIME
• The volume control is adjustable.
• Refer to the procedures below when
using the Message Center functions.
7
INSTANT
8
9
READY
0
#
STATUS
VOICE
FUNCTION
MICROPHONE
FUNCTION
KEYS
Message Center Functions
To…
Press these keys…
Notes…
The red MESSAGE LED lights.
Message remains in memory until a
new message is recorded.
record a
message
#
0
1
OFF
+
+
FUNCTION VOICE RECORD
The red MESSAGE LED flashes,
indicating message waiting.
end
recording
1
OFF
RECORD
The recorded message plays and the
red MESSAGE LED turns off.
play a
message
#
0
3
2
STAY
PLAY
AWAY
+
+
+
FUNCTION VOICE
Adjusting message volume also
adjusts status volume. Volume
cannot be adjusted while playing.
adjust the
volume
#
0
+
, then press
FUNCTION VOICE
VOLUME
volume key [3] ↑ (up) or [6] ↓ (down)
– 7 –
Download from Www.Somanuals.com. All Manuals Search And Download.
About The Keypads
General Information
Your keypads allow you to control all system functions and feature the following:
• A telephone style (digital) keypad
• Liquid Crystal Displays (LCD) that show the nature and location of all occurrences
• Built-in sounder that sounds during alarms and troubles. The sounder also "beeps"
during certain system functions and also when depressing any of the keys (to
acknowledge the key press).
• Backlighting of the LCD display windows. Backlighting turns on when any key is
pressed or when entering the premises through any assigned entry/exit door. This
feature is helpful when a keypad is located in a dimly lit area.
• Some keypads have a voice feature that announces the nature and location of all
system occurrences. Voice keypads also announce any faulted entry/exit or
perimeter zone when Chime mode is on. Ask your installer if this option has been
programmed for your system.
IMPORTANT: If the keypad beeps rapidly upon entering the premises, it indicates that an
alarm has occurred during your absence and an intruder may still be on the premises.
LEAVE IMMEDIATELY and CONTACT THE POLICE from a nearby safe location.
Your keypads are functionally the same, but may have different types of displays,
depending on the type installed with your system.
Alpha Display
2-line alpha display keypads feature a 2-line, 32-character
alphanumeric LCD that displays system messages in friendly
English. These keypads can also be programmed with custom
zone descriptors.
Fixed-Word Display
Voice Keypads
Fixed-Word display keypads are functionally identical to
Alpha display keypads, but the LCD display uses pre-
designated words to identify the nature and location of
occurrences.
Voice Keypads (if installed), are functionally the same as other
keypads, except that these keypads can provide the following:
• Voice announcements of system status (see Checking for
Open Zones section)
• Voice chime, which can alert you to the opening of doors and
windows while the system is disarmed (see Voice Chime in
Chime mode section)
• Message center, which lets you record and playback
messages (see Using the Voice Message Center in the
System Overview section).
– 8 –
Download from Www.Somanuals.com. All Manuals Search And Download.
About The Keypads (cont’d)
ARMED
ARMED
READY
OFF
MAX
AWAY
TEST
CODE
STAY
BYPASS
CHIME
OFF
MAX
AWAY
TEST
CODE
STAY
3
BYPASS
6
CHIME
9
#
1
4
7
2
5
8
0
3
6
9
#
1
4
7
2
5
8
0
READY
INSTANT
READY
INSTANT
READY
Standard Alpha Display Keypad
Standard Fixed-Word Display Keypad
ARMED
READY
MESSAGE
MIC
OFF
AWAY
STAY
1
2
3
6
9
#
RECORD
VOLUME
PLAY
MAX
TEST
BYPASS
CHIME
4
5
CODE
7
INSTANT
8
READY
0
STATUS
VOICE
FUNCTION
Voice-Capable Alpha Display Keypad
– 9 –
Download from Www.Somanuals.com. All Manuals Search And Download.
About The Keypads (Cont’d)
FIXED-WORD DISPLAY KEYPAD
AWAY: All burglary zones, interior and
perimeter, are armed.
STAY: Perimeter burglary zones, such as
protected windows and doors, are
armed.
NIGHT NO AC
PHONE TEST
NOT READY
CHIME BAT
AWAY
BYPASS
ALARM STAY
CHECK INSTANT CANCELED
FIRE
6150disp
NIGHT-STAY: NIGHT and STAY indicators both
light when perimeter burglary
zones plus pre-selected interior
zones (set by the installer) are
armed.
FIXED-WORD DISPLAY
INSTANT: Entry delay is turned off:
Lit with STAY = Instant mode
Lit with AWAY = Maximum mode
BYPASS: This appears when one or more burglary protection zones have been
bypassed.
NOT READY: Appears when burglary portion of the system is not ready for arming (due
to open protection zones). The system is ready to arm when this message
disappears and the READY indicator light comes on.
NO AC: Appears when AC power has been cut off. System is operating on backup
battery power.
AC: Appears when AC power is present.
CHIME: Appears when the chime feature is activated.
BAT: Low battery condition in a wireless sensor (if zone number displayed) or
low system battery (if no zone number displayed).
ALARM: Appears when an intrusion has been detected and the system is armed
(also appears during a fire alarm or audible emergency alarm).
Accompanied by the protection zone in alarm.
CHECK: Appears when a malfunction is discovered in the system at any time, or if
an open is detected in a fire zone at any time, or a fault in a DAY/NIGHT
burglary zone during a disarmed period. Accompanied by a display of
zone number in trouble.
FIRE: Appears when a fire alarm is generated. Accompanied by a display of the
zone in alarm.
A FIRE display also appears when a fire alarm is manually activated,
accompanied by a display of the fire emergency key zone number.
CANCELED: Appears when an alarm has been silenced by the Code + OFF sequence
and will remain on until another Code + OFF sequence is keyed.
– 10 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Functions of the Keypads
2
1
3
4
20
19
18
5
17
16
15
STAY
ARMED
READY
MESSAGE
MIC
6
7
8
OFF
AWAY
1
2
3
6
9
#
RECORD
VOLUME
PLAY
MAX
TEST
BYPASS
4
5
9
CODE
CHIME
INSTANT
8
7
READY
0
10
STATUS
VOICE
FUNCTION
14
13
12
11
Voice-capable 2-line Alpha keypad
(shown with flip-down front door removed)
IMPORTANT!
•
Match the numerical callouts in the above graphic with the corresponding number on the
following pages for a description of usage.
•
When entering codes and commands, sequential key depressions must be made within 4-5
seconds of one another. If 4-5 seconds elapse without a key depression, the entry will be
aborted and must be repeated from its beginning. Be sure to observe this precaution when
performing any of the procedures in this manual.
• If you make a mistake while entering a security code, stop, press the [✱] key, and then
start over. If you stop in the middle while entering a code, and then immediately start
the entry over, an erroneous code might be entered.
– 11 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Functions of the Keypads (cont’d)
[PLAY] On Voice keypads, used in
NOTE: The functions printed directly on the
keys indicate their primary purpose; the
functions printed under some of the keys (shown
in brackets under the respective key), indicate
their alternate or secondary purpose.
conjunction with the FUNCTION and
VOICE keys to play the recorded
message.
[
↑ ] On Voice keypads, used in
1. DISPLAY WINDOW
conjunction with the FUNCTION and
VOLUME keys to raise the message
and voice system status volume.
Alpha Display Keypads: 2-line, 32-
character Liquid Crystal Display (LCD)
keypads that display protection point
identification, system status, and
messages.
5.
4
MAX Arms the entire burglary
system, perimeter and interior, but
without entry delay feature. Entering
via an entry/exit door will cause an
alarm.
Fixed-Word Display Keypads:
Display protection zone ID and system
status messages using pre-designated
words in the LCD display area.
6. 5 TEST Tests the system and alarm
sounder if disarmed. Refer to Testing
The System section for test procedures.
2.
1
OFF
Disarms burglary portion of
system, silences alarms and audible
the
trouble indicators, and clears visual
display after problem's correction.
[RECORD] On Voice keypads, used in
conjunction with the FUNCTION and
VOICE keys to record up to a 2.5-
minute message.
7. 6 BYPASS
Removes
individual
protection zones from being monitored
by the system.
[
↓ ] On Voice keypads, used in
conjunction with the FUNCTION and
VOLUME keys to lower the message
and voice system status volume.
3. 2 AWAY
Arms the entire burglary
8. 7 INSTANT Arms in manner similar to
perimeter and interior.
system,
the STAY mode, but without the entry
delay feature.
Entering via an entry/exit door will
cause an alarm.
[VOLUME] On Voice keypads, used in
conjunction with the FUNCTION and
desired volume control keys ↑ [3] or ↓
[6] to adjust the volume of a recorded
message or voice system status.
9. 8 CODE Used to assign additional
4.
3
STAY Arms perimeter portion of
security codes and attributes for other
users of the system.
burglary system only. Interior
protection is not armed, allowing
movement within premises without
causing an alarm. If pressed twice in
succession, arms system in Night-Stay
mode.
10. 9 CHIME
Turns CHIME mode on and
When on, the opening of windows or
off.
doors while the system is disarmed will
sound 3 beeps at the keypad(s).
– 12 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Functions of the Keypads (cont’d)
15. MIC
On voice keypads, microphone for
11. #
This key can be used for "Quick
Arming" of the system without use of a
security code (if programmed).
Message Center recordings.
16. MESSAGE LED INDICATOR: (RED)
On Voice keypads, flashes red when
message waiting or lights red (steady)
when in record mode.
[FUNCTION] On Voice keypads, enables
the desired voice or volume function.
12. 0
[VOICE] On Voice keypads, enables the
17. READY LED INDICATOR: (GREEN)
Lit when the system is ready to be
armed (no faults present). While the
system is disarmed, this indicator will
go on and off as protection zones are
closed and opened.
RECORD,
functions.
VOLUME
and
PLAY
13. ∗ READY Used to display all open
protection zones.
[STATUS] On Voice keypads,
a
18. ARMED LED INDICATOR: (RED)
momentary press of the STATUS key
annunciates the current system status.
Pressing the STATUS key a second
time annunciates and displays system
and/or zone faults (if they exist).
Lit when the system has been armed.
19. FUNCTION KEYS: Keys A, B, C, D
may have been programmed for a
variety of functions, including panic
(emergency) functions. For details, see
the Function Keys section.
14. KEYS 0–9: Used to enter your security
code(s).
20. INTERNAL SPEAKER: The built-in
speaker mimics the alarm sounder
during alarms, and will also "beep"
during certain system functions. The
speaker also provides voice playback for
any recorded messages.
– 13 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Entry/Exit Delays
Entry Delay
Entry Delays give you time to disarm the system when you re-enter through the
designated entrance door. There are two entry delays (if programmed). The first is for
your primary entrance and the second can be used for a secondary entrance, where a
longer delay is required to walk to the keypad to disarm the system.
You must disarm the system before the entry delay period ends, or an alarm will
occur. The keypad beeps during the entry delay period, reminding you to disarm the
system. The beeps stop when a code is entered, but will restart after about 15 seconds
if an invalid code is entered.
You can also arm the system with no entry delay at all by using the INSTANT or
MAXIMUM arming modes. These modes provide greater security while on the
premises or while away for extended periods of time.
See your installer for your delay times.
Partition 1____________________________________________________________________________
Exit Delay:
seconds
Entry Delay 1:
seconds
Entry Delay 2:
seconds
NOTE: Entry/Exit times set for partition 1 also apply to the Common Zone.
Partition 2____________________________________________________________________________
Exit Delay:
seconds
Entry Delay 1:
seconds
Entry Delay 2:
seconds
Exit Delay
Exit delay gives you time to leave through the designated exit door(s) without
setting off an alarm. Exit delay begins immediately after arming your system in
any arming mode and Alpha Display keypads display the message “You May Exit
Now.” When “You may exit now” disappears, the system is fully armed. If
programmed, a slow beeping will sound during the exit delay period until the last
10 seconds, which then changes to fast beeping (alerting you to the end of exit
delay). If you cannot leave within this delay time period, you should stop, disarm
the system, and start over to avoid a false alarm.
Exit Delay Restart (if programmed):If you wish to open the entry/exit door to let
someone in after arming STAY (the perimeter zones remain armed), you can restart
the exit delay at any time – simply press the [✱] key, then let that person in. The
system automatically rearms the entry/exit door when the exit delay expires, which
avoids having to disarm the system and then rearm it again.
Additionally, when the system is armed AWAY, reopening and closing the
entry/exit door before exit delay time expires (e.g., re-entering to get a forgotten
item), will reset the exit delay time once.
– 14 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Entry/Exit Delays (cont’d)
Exit Alarms
Exit Error Conditions
Whenever you arm the system, the exit delay begins. If an entry/exit door or interior
zone is faulted before exit delay expires and remains faulted (e.g., exit door left open),
the system sounds an alarm and starts the entry delay timer. If you disarm the
system before the entry delay ends, the alarm sound stops and the message "ALARM
CANCELED " or "CA" is displayed on the keypad, along with a zone number
indicating the faulted zone. No message is sent to the Central Monitoring Station.
To clear the exit error condition, the open zone must be made intact; to clear the
display, enter your code plus OFF.
If you do not disarm the system before the entry delay ends and the faulted zone
remains open, the alarm sound continues and an "exit alarm" message is sent to the
Central Monitoring Station (after the installer-programmed dial delay expires). The
message "EXIT ALARM" or "EA" is displayed on the keypad, along with a zone
number indicating the faulted zone. To stop the alarm, the system must be disarmed
(your code plus OFF); to clear the display, enter your code plus OFF a second time.
An “exit alarm” also results if an entry/exit door or interior zone is faulted within two
minutes after the end of the exit delay.
Your system may have been programmed for this feature to minimize false alarms sent to the Central Monitoring
Station. Ask your installer if "Exit Alarm" is active in your system. If so, check this box.
VISTA-21iPSIA: The Exit Error condition works the same as described above, except that in
addition to the “EXIT ALARM” message, a “zone alarm” message is also sent to the Central
Monitoring Station. In addition, if an entry/exit door or interior zone is faulted within two
minutes after the end of the exit delay, a “Recent Closing” condition occurs instead of the “exit
alarm.” Refer to the next paragraph for details.
“Recent Closing” Condition (VISTA-21iPSIA)
A Recent Closing condition is similar to the Exit Error condition described above, but occurs if
an entry/exit door or interior zone is faulted within two minutes after the initial exit delay
expires. If you disarm the system within the two minutes, the alarm sound stops and the
message "ALARM CANCELED " or "CA" is displayed on the keypad, along with a zone number
indicating the faulted zone. No message is sent to the Central Monitoring Station.
If you do not disarm the system within two minutes and the faulted zone remains open, the
alarm sound continues and a “recent closing” and a “zone alarm” message are sent to the
Central Monitoring Station (after the installer-programmed dial delay expires). The alarm
message along with a faulted zone number is displayed on the keypad. To stop the alarm, the
system must be disarmed (your code plus OFF); to clear the display, enter your code plus OFF a
second time.
– 15 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Checking For Open Zones
Using the [∗] Key to Display and Announce System Status
Before arming your system, all protected doors, windows and other protection zones
must be closed or bypassed; otherwise the keypad will display a "Not Ready"
message.
Use the READY key to display all faulted zones, making it easier for you to identify
and secure any open zone.
1. Press [✱] (do not enter code first) to display faulted
zones.
2. Secure or bypass the zones displayed.
The keypad’s READY indicator lights when all
protection zones have been either closed or bypassed.
3. Arm the system as desired.
Alpha Display:
DISARMED
HIT ∗ FOR FAULTS
Fixed-Word Display:
Zone no. and “NOT READY”
Voice Status: Voice keypads (if installed), can announce system status and faulted
zones (up to 3 zone descriptors) if the Voice Status feature is turned on.
To turn the Voice Status feature on/off:
#
+
0
+
2
+
4
(also turns on Voice Chime mode; see Chime mode section)
To announce Status: Press [#] FUNCTION + [0] VOICE + [∗] STATUS key.
(Announces current system status; e.g., “Disarmed Ready to
Arm.”)
To announce faults Press [#] FUNCTION + [0] VOICE + [∗] STATUS + [∗] again
and status:
(Announces up to three faulted zones with their zone
descriptors, if programmed.)
– 16 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Arming the System
STAY Mode: Arms Perimeter Only, Entry Delay On
• Used when you want to arm the system with persons staying inside (or if you have
pets that are moving throughout the premises).
• The perimeter sensors are armed, but interior sensors are left disarmed.
• Exit delay begins (you can leave through the entry/exit door, if desired).
• An alarm sounds if any protected window or non-entry/exit door is opened.
• You may otherwise move freely within the premises.
• Persons entering later can enter through an entry/exit door, but they must disarm
the system within the entry delay period to avoid sounding an alarm.
NIGHT-STAY Mode: Arms Perimeter Only, Plus Selected Zones
• Use NIGHT-STAY mode to provide increased security while staying inside.
• Arms same as STAY mode, but also arms preselected interior sensors (programmed
by your installer), while other interior sensors are left disarmed.
• Persons entering later can enter through an entry/exit door but they must disarm
the system and must not violate any of the programmed interior zones to avoid
sounding an alarm.
• IMPORTANT: When NIGHT-STAY mode is on, the selected interior zones are
armed and cause an alarm if anyone enters those areas (e.g., waking in the middle
of the night). To avoid sounding an alarm, you must disarm the system before any
activity takes place in those interior zones.
INSTANT Mode: Arms Perimeter Only, Entry Delay Off
• Used when staying inside and do not expect anyone to use an entry/exit door.
• Arms same as STAY mode.
• An alarm sounds immediately if any protected perimeter window or any door is
opened, including entry/exit doors.
• IMPORTANT: Arming the system in this mode greatly increases the chance of
false alarms. Use extreme care in selecting this mode of arming.
AWAY Mode: Arms Entire System, Entry Delay On
• Used when nobody will be staying inside (including pets).
• The entire system (interior and perimeter) is armed.
• Exit delay begins letting you leave through the entry/exit door.
• An alarm sounds if a protected window or any door is opened, or if any movement
is detected inside your premises.
• You can re-enter through an entry/exit door, but you must disarm the system
within the entry delay period to avoid sounding an alarm.
MAXIMUM Mode: Arms Entire System, Entry Delay Off
• Used when leaving the premises for extended periods (e.g., vacation).
• Arms same as Away mode, but entry delay is off.
• An alarm sounds same as Away mode, and sounds upon opening entry/exit doors.
– 17 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Arming the System (cont’d)
Arming Commands
Before arming, close all perimeter doors and windows and make sure the Ready to Arm
message is displayed.
Mode
Press these keys…
Keypad Confirms By…
• three beeps†
security code + 3 STAY
STAY
• armed STAY message displayed
• red ARMED indicator lights
• three beeps†
• NIGHT-STAY message displayed
• red ARMED indicator lights
• three beeps†
• armed STAY message displayed
• red ARMED indicator lights
Note that entry delay is turned off.
security code + 3 STAY + 3 STAY
security code + 7 INSTANT
NIGHT-
STAY
INSTANT
two beeps†, or, if programmed, beeping for
duration of exit delay
security code + 2 AWAY
AWAY
• armed AWAY message displayed
• red ARMED indicator lights
Leave the premises through an entry/exit
door during the exit delay period to avoid
causing an alarm. The keypad beeps
rapidly during the last 10 seconds of the
exit delay to warn you that it is ending.
• same as AWAY (described above)
Note that entry delay is turned off.
security code + 4 MAX
MAXIMUM
† Arming Ding: In addition to the keypad beeps, the external sounder emits a short “ding” sound after arming, if
programmed to do so. The ding confirms that the system is armed, and may occur immediately after the command or be
delayed (until arm/disarm report is sent or exit delay expires). Ask your installer about how this feature is set for your system.
Quick Arming
If "Quick Arming" was programmed by the installer, the [#] key can be pressed in place
of the security code when arming the system in any of the arming modes (except Night-
Stay). However, the security code must always be used when manually
disarming the system.
Function Key Arming
For any arming command, a function key may have also been programmed for your
system. If so, you can press and hold the appropriate function key for 2 seconds to arm
the system. See your installer for the designated functions (see Single Button
Arming section).
Refer to the Accessing Other Partitions section for information on multi-partition
arming.
– 18 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Arming the System (cont’d)
Single Button Arming
The “A”, “B”, “C”, and/or “D” keys on your keypad may have been programmed for
single-button arming. Note that while it is not necessary to use a security code for
arming (by using the Quick Arm method described previously), a security code must
always be used when manually disarming the system.
If Single-Button Arming is programmed:
•
A function key has been assigned to a specific type of arming: STAY mode,
NIGHT-STAY mode, AWAY mode, or STEP-ARMING (see Step-Arming
paragraph).
•
You DO NOT need to enter your security code before pressing the function key
but you always need your security code to DISARM the system.
Before arming, close all perimeter doors and windows.
Alpha Display:
1. Press and hold the assigned function key for 2
seconds (no code is required). Function keys are
shown below.
DISARMED
READY TO ARM
OFF
AWAY
TEST
CODE
STAY
A
B
C
D
1
4
7
2
5
8
0
3
6
9
#
BYPASS
Fixed-Word Display: Green LED lit
INSTANT
READY
CHECK
ADT3000-007-V0
*
2. The keypad begins beeping and displays the
armed message. The red ARMED indicator also
lights.
Alpha Display:
ARMED***AWAY***
YOU MAY EXIT NOW
Fixed-Word Display: AWAY
Single Button “Step” Arming
Single-Button “Step” arming may be programmed into one of the lettered keys (A, B,
C, or D). Check with your installer to see if this has been done in your system.
If Step-Arming is programmed:
•
•
The assigned key provides a choice of three levels of security.
The selected key can be pressed once, twice, or three times, increasing the level of
security with each press, as follows
Key
First Press
Second Press
Third Press
Ø
Ø
Ø
Ø
Armed-STAY Armed NIGHT-STAY Armed-AWAY
A, B, C, D
(if programmed)
– 19 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyswitch
Using the Keyswitch
Your system may be equipped with a keyswitch for use when arming and disarming.
Red and green lights on the keyswitch plate indicate the status of your system as
follows:
Green Light: Lights when the system is disarmed and ready to be armed (no
open zones). If the system is disarmed and the green light is off, it
indicates the system is not ready (one or more zones are open).
Red Light:
Lights or flashes when system is armed in AWAY or STAY mode.
See your installer for the meanings of the lit red light:
Lit Steady = system armed AWAY or
system armed STAY and exit delay has expired
Flashing = system armed STAY and exit delay timer active
Rapid flashing = an alarm has occurred (memory of alarm).
Before arming, close all perimeter doors and windows.
To arm in the AWAY mode:
Turn the key to the right for 1/2 second and release.
Keypads beep twice and the red indicator lights or
flashes.
GREEN
RED
To arm in the STAY mode:
Turn the key to the right and hold for longer than 1
second, then release. Keypads beep three times and
the red indicator lights or flashes.
keyswitch-001-V1
To disarm the system:
Turn the key to the right and release. The red light
turns off
– 20 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Disarming and Silencing Alarms
Using the [OFF] key
The OFF key is used to disarm the system, silence alarm and trouble sounds, and
clear alarm memories.
IMPORTANT: If you return and the main burglary sounder is on, DO NOT
ENTER, but CONTACT THE POLICE from a nearby safe location.
If you return after an alarm has occurred and the main sounder has shut itself off,
the keypad will beep rapidly upon your entering, indicating that an alarm
has occurred during your absence.
LEAVE AT ONCE, and CONTACT THE POLICE from a nearby safe location.
Alpha Display:
1.
+
1
OFF
(Security Code)
∗∗∗∗DISARMED∗∗∗∗
The “READY” indicator light will be lit if all zones
are secure, and the keypad will emit a single tone to
confirm that the system is disarmed.
READY TO ARM
Fixed-Word Display: READY
NOTE: If entry delay has started (you’ve opened the
entry door), you do not need to press the OFF key –
simply enter your security code. The system will
disarm in about 15 seconds after the last digit of the
code is entered.
2. To Silence a Burglary Alarm and Clear a Memory of Alarm
Enter your security code and press the OFF key to silence the alarm (or
warning tones of a Memory of Alarm).
Note the zone in alarm on the keypad display, and correct the problem (close
door, window, etc.). After correcting the problem, enter the security code plus
OFF sequence again to clear the keypad’s Memory of Alarm display.
3. To Silence a Fire Alarm or Carbon Monoxide Alarm and Clear a Memory of
Alarm
Simply press the OFF key to silence the alarm. Then enter the security code
plus OFF sequence twice to clear the keypad's Memory of Alarm display. See the
Fire Alarm System section.
– 21 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Bypassing Protection Zones
Using the BYPASS Key
Use this key when you want to arm your system with one or more zones
intentionally unprotected. The system must be disarmed first.
Vent Zones: Your system may have certain windows set as “vent” zones, which are
automatically bypassed if left open when arming the system (you do not need to
manually bypass them). However, if a vent zone window is closed after arming, it
becomes protected and will cause an alarm if opened again while the system is
armed.
When bypassing zones:
•
•
•
•
The system must be disarmed before you can bypass zones.
Bypassed zones are unprotected and will not cause an alarm if violated.
The system will not allow fire zones to be bypassed.
Zones are automatically unbypassed when the system is disarmed.
Alpha Display:
1.
+ 6 BYPASS + zone numbers (see below)
(Security Code)
DISARMED
Enter the 2-digit zone number(s) for the zone(s) to be
bypassed (e.g., 06, 10, 13, etc.). Single digit zone
numbers must be preceded by a zero (e.g. 05, 06).
HIT ∗ FOR FAULTS
Fixed-Word Display:
NOT READY
2. When finished, the keypad will momentarily display a
"Bypass" message for each bypassed zone number.
Wait for all bypassed zones to be displayed.
Alpha Display:
DISARMED BYPASS
READY TO ARM
Arm the system as usual. When armed, the arming
message is displayed with “ZONE BYPASSED.”
To display bypassed zones prior to arming, enter
Fixed-Word Display: BYPASS
your security code and press the [6] BYPASS key.
Alpha Display:
ARMED: STAY
ZONE BYPASSED
Typical armed display after
bypassing zones.
– 22 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Bypassing Protection Zones (cont’d)
Quick Bypass
If programmed, "Quick Bypass" allows you to easily bypass all open (faulted) zones
without having to enter zone numbers individually. This feature is useful if, for
example, you routinely leave certain windows open when arming at night.
Alpha Display:
1.
+
6 BYPASS + [#]
(Security Code)
DISARMED
In a few moments, all open zones will be displayed
and automatically bypassed. Make sure that only
those zones that you wish to leave unprotected are
bypassed, and that there are no other zones
unintentionally left open.
HIT ∗ FOR FAULTS
Fixed-Word Display: NOT
READY
Alpha Display:
2. Wait for all bypassed zones to be displayed, then arm
the system as desired.
DISARMED BYPASS
READY TO ARM
Ask your installer if "Quick Bypass" is active for your
system, and if so, check here:
Fixed-Word Display: BYPASS
– 23 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Chime Mode
Using the Chime Mode
CHIME mode alerts you to the opening of a perimeter door or window while the
system is disarmed.
When Chime mode is activated:
• Three tones sound at the keypad whenever a perimeter door or window is opened.
• Interior zones do not produce a tone when they are faulted.
• Pressing the READY key will display the open protection points.
• Chime mode can be used only while the system is disarmed.
To turn Chime Mode on:
Alpha Display:
+
9 CHIME
DISARMED CHIME
(Security Code)
READY TO ARM
The CHIME message will appear. Perimeter zones
will cause a tone when faulted.
Fixed-Word Display: CHIME
To turn Chime Mode off:
Alpha Display:
+
9 CHIME
∗∗∗∗DISARMED∗∗∗∗
(Security Code)
The CHIME message will disappear.
READY TO ARM
Fixed-Word Display: READY
Using the Voice Chime
Voice keypads have a feature that works in concert with the Chime Mode called Voice
Chime. Voice chime provides a voice status annunciation, chime, and display when
any faulted entry/exit or perimeter zone exists. Ask your installer if this option has
been enabled for your system.
To turn Voice Chime Mode on or off:
#
+
0
+
2
+
4
(normal Chime mode must be on first)
When Voice Chime is on, faulted zones cause a voice status announcement, chime and display.
When off, the sounder still provides chime if normal Chime mode is on.
– 24 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Date and Time
Viewing the Current Date and Time
The master users can view the system time and date setting on an alpha keypad.
Other users can view the time/date if a function key has been programmed to do so.
Alpha Display:
+ [#] + [6] [3]
(Master Code)
∗∗∗∗DISARMED∗∗∗∗
OR,
READY TO ARM
Press the function key (A, B, C, or D) for viewing
current date and time, if programmed.
A typical time/date display is shown.
The display will remain on for about 30 seconds or until
a key is pressed.
TIME/DATE
12:05AM_05/09/00
SAT
“A”
“B”
“C”
“D”
If one of the above keys has been programmed for the date/time display feature,
place a check mark in the box beneath that key.
Setting the Date and Time
NOTE: All partitions must be disarmed before date/time can be set.
You can set the time and date by doing the following:
Alpha Display:
1.
+[#] + [6] [3]
(Master Code)
∗∗∗∗DISARMED∗∗∗∗
READY TO ARM
2. Press [∗] when the time/date is displayed.
TIME/DATE
04:04PM 10/17/00
SAT
A cursor appears under the first digit of the hour.
To move cursor ahead, press [∗]. To go back, press [#].
• Enter the 2-digit hour setting.
Current time display
• Enter the 2-digit minute setting.
• Press [1] for PM or [2] for AM.
• Enter the last two digits of the current year.
• Enter the 2-digit month setting.
• Enter the 2-digit day setting.
TIME/DATE
04:04P2000/10/17
Time/date editing display
SAT
3. To exit, press [∗] when cursor is at the last digit, or
wait 30 seconds.
– 25 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Panic Keys
Using Panic Keys
Your system may have been programmed to use special keys to manually activate
emergency (panic) functions as follows:
This Function
Sends This Signal*
With This Sounding…
Silent Alarm
silent alarm
no audible alarm; displays, “Press [∗]
to show faults,” indicating that a
silent alarm has been initiated.
a loud, steady alarm at keypad(s) and
at any external sounders that may be
connected.
Audible Alarm
audible alarm
Personal Alarm
Fire Alarm
auxiliary alarm
fire alarm
steady alarm sound at keypad(s), but
not at external bells or sirens.
temporal (pulsing) sound at external
bells and sirens.
*All panic functions send signals to the Central Monitoring Station, if connected.
Normal Alpha Display:
To activate a Panic Function:
∗∗∗∗DISARMED∗∗∗∗
Press and hold down for at least 2 seconds whichever
lettered key on the keypad has been programmed for
the desired emergency function.
READY TO ARM
Fixed-Word Display: READY
Typical Panic Alpha Display:
OR
ALARM 96 ZONE 96
Press both keys of the assigned key pair at the same
time.
Fixed-Word Display: 96 and ALARM
PRESS BOTH KEYS
OF DESIRED PAIR
AT THE SAME TIME
A
ZONE 95
ARMED
OFF
MAX
AWAY
TEST
CODE
STAY
BYPASS
CHIME
1
4
7
2
5
8
0
3
6
9
#
READY
B
ARMED
ZONE 96
OFF
MAX
AWAY
TEST
CODE
STAY
BYPASS
CHIME
1
4
7
2
5
8
0
3
6
9
#
ZONE 95
ZONE 99
INSTANT
READY
READY
INSTANT
READY
C
ZONE 96
D
ZONE 99
Lettered Panic Keys
Panic Key Pairs
See your installer and use the chart provided in the Features Programmed in Your
System section to note the functions that have been programmed for your system.
– 26 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Macro Key Programming & Usage
About Macro Keys
The “A”, “B”, “C” or “D” keys can be used to automatically activate a series of
commands of up to 16 keystrokes, if programmed for this function. These keystrokes,
as a group, are called “macros” and are stored in the system's memory.
• Typical macro functions can include:
-
-
-
Arming sequences: STAY, NIGHT-STAY, INSTANT, or AWAY
Bypassing particular zone(s)
Activating relay(s) for turning on (or off) lights, fans, etc.
• Up to four macros can be assigned – but no more than one macro to a key.
• Macros can be activated only by users with authority levels authorized to
perform the macro’s function.
NOTE: The installer must activate the desired function key (using *57 Function
key Menu Mode) before macros can be assigned.
See the chart at the back of this manual for the key(s) assigned for macros.
Alpha Display:
1.
+ [#] + [6] + [6]
(Master Code)
∗∗∗∗DISARMED∗∗∗∗
READY TO ARM
2. Enter the macro number (1-4) to be programmed at the
“Select Macro?” prompt. Remember, only one macro
can be assigned to each key.
SELECT MACRO
1-4
0
3. If a macro has been previously defined, the keystrokes
are shown on the bottom line of the display; otherwise
the display is blank.
MACRO DISPLAY
To exit this mode (and keep the existing macro
definition), press any key except the [∗] key. The
system returns to normal mode.
To define a macro for the selected key, press [∗] and
continue with the next prompt.
Enter the first of the series of desired commands, (do
not include your master code), then press/hold the “D”
key for at least two seconds to complete the first
command. This key terminates each command, and
appears as an “F” in the keypad display.
MACRO PGM
– 27 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Macro Key Programming & Usage (cont’d)
The keypad beeps to acknowledge your input and displays the command you
entered (followed by “F”).
4. Enter the next command, followed by press/holding the “D” key for at least two
seconds. The keypad beeps and displays the keystrokes entered so far.
5. Repeat until the all the desired commands (up to 16 characters including the “F”s)
have been entered.
Be sure to check your keystrokes before continuing. If you made a mistake, you
must start over.
6.
To exit, press/hold the “D” key for at least two seconds. The display returns to
system status and indicates system is ready.
Example of Macro Programming
Typical Macro Alpha Display:
Suppose you want to (1) bypass the two upstairs window
zones, then (2) turn on an exterior light, and then (3) arm
the security system in the AWAY mode. The procedures
in the table that follows show you how you would
program this macro:
MACRO PGM
60203F#701F2F
Function
Keystrokes Required
Keypad Display
1. Bypass zones 02 & 03
Press BYPASS [6] key, then
2-digit zone numbers 02 & 03.
6 0 2 0 3
2. Insert terminator
3. Turn light on
Press the “D” key for at least 2 seconds.
Press [#] and 7 key for “device ON”, and
[01] key for selecting device 1.
6 0 2 0 3 F
6 0 2 0 3 F # 7 0 1
(device 01)
4. Insert terminator
5. Arm system AWAY
6. Insert terminator
Press the “D” key for at least 2 seconds.
Press AWAY [2] key.
6 0 2 0 3 F # 7 0 1 F
6 0 2 0 3 F # 7 0 1 F 2
6 0 2 0 3 F # 7 0 1 F 2 F
Press the “D” key for at least 2 seconds.
Using a Programmed Macro Key
1. Press the Macro key programmed for the desired
series of commands for at least 2 seconds. The “Enter
User Code” prompt appears. The prompt remains
displayed for up to 30 seconds.
∗∗∗∗DISARMED∗∗∗∗
READY TO ARM
2. Enter your 4-digit security code.
ENTER USER CODE
The programmed macro sequence begins
automatically after the user code is entered.
∗ ∗ ∗ ∗
– 28 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Using Device Commands
About Device Commands
Your system may be set up so that it can control certain lights or other devices.
• Some devices may be automatically turned on or off by the system.
• You may be able to override automatically controlled devices using the
commands described below.
• Some devices can be manually turned on or off using the commands described
below.
• See your installer for a list of devices that may be set up for your system. A list
of these devices is provided at the back of this manual for you to fill out.
To Activate Devices:
+ [#] + [7] + 2-digit device number
Alpha Display:
∗∗∗∗DISARMED∗∗∗∗
(Security Code)
READY TO ARM
Devices associated with that device number activate.
Fixed-Word Display: READY
To Deactivate Devices:
+ [#] + [8] + 2-digit device number
(Security Code)
Devices associated with that device number deactivate.
– 29 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Paging Feature
About Automatic Paging
Your system may be set up to automatically send messages to up to four pagers as
certain conditions occur in your system.
• The following events can be programmed by your installer to be sent to the pagers:
arming and disarming†, alarms, and trouble conditions. († reports when
arming/disarming from a keypad using a security code; auto-arming/disarming,
arming with assigned button, and keyswitch arming do not send pager messages.)
• You can also program the system to send an automatic pager message to alert you
in the event that someone has not arrived home (disarmed the system) within a
defined period of time (see the Scheduling section for details on programming a
“latch key report”).
• Your installer programs the pager phone numbers and reporting events.
• The pager message consists of a 7-digit system status code that indicates the type of
condition that has occurred.
• An optional, predefined 16-digit character string can precede the 7-digit system
status code; these characters can consist of a PIN no., subscriber account no., or any
additional data that you may wish to have sent to the pager.
• The pager display format is as follows:
3-digit Event Code
Optional 16 digits
È
È
Å 1-digit Partition No. + 3-digit Zone No. or User No.
AAAAAAAAAAAAAAAA – BBB – CCCC
A = B =
Optional 16-digits for A 3-digit code that
C =
A 1-digit Partition number plus a 3-digit Zone or User
Account numbers,
PIN numbers, or any
other data;
programmed by the
installer, if required.
describes the event number, depending on the type of event that has
that has occurred
in your system
(see for event
occurred, where:
• alarms and troubles display zone number
• arming/disarming (opens/closes) display user number
codes table below)
The 3-digit Event Codes (BBB) that can be displayed are:
911 =
Alarms.
811 =
Troubles.
101 =
Open
102 =
Close
The 4-digit number
(CCCC) following this
code is the partition no. code is the partition no.
and zone no. that
caused the alarm.
The 4-digit number
(CCCC) following this
(system disarmed).
The 4-digit number
(CCCC) that follows
this code is the
partition no. and user
no. that disarmed the
system.
(system armed).
The 4-digit number
(CCCC) that follows
this code is the
partition no. and user
no. that armed the
system.
and zone no. or device
address that caused the
trouble.
Examples of typical 7-digit pager displays follow.
Ex. 1. 9 1 1 – 1 0 0 4 = Reporting of an alarm (911) caused by a fault on zone 4 on Partition 1 (1004).
Ex. 2. 1 0 2 – 2 0 0 5 = Reporting of a closing–system arming (102)– by user 5 in Partition 2 (2005).
– 30 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Paging Feature (cont’d)
About Manual Paging
Your system may be set up so you can manually send a message to up to four pagers.
• Your installer programs the paging function key and the pager phone numbers.
• Pressing the paging keys sends the message 9 9 9 – 9 9 9 9
to the selected pager.
• This message could mean “call home”, “call your office”, or any other prearranged
meaning.
• See the Paging chart at the back of this manual for details of the paging setup for
your system.
1. Press and hold the programmed Paging Key for at
least 2 seconds (wait for beep), then press the pager
number* (1-4) representing the pager intended to
receive the message.
Alpha Display:
∗∗∗∗DISARMED∗∗∗∗
READY TO ARM
2. The recipient, on seeing the 999–9999 message, will
understand the prearranged meaning of this signal.
Fixed-Word Display: READY
* If no number is pressed, the message is sent to pager 1.
999-9999
Pager Display
Latch Key Paging
You can program a schedule that causes a pager report to be sent if the system is not
DISARMED by the scheduled time (see Scheduling section, event “03”). For example,
a working parent might want a message to be sent to a pager if their child did not
arrive home from school and disarm the system by a certain time.
If programmed, the message that is sent is: 7 7 7 – 7 7 7 7
.
– 31 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Security Codes & Authority Levels
About Security Codes
Your installer assigned a master code that is used to perform all system functions.
In addition, you can assign up to 47 different security codes for use by other users.
• Only the System Master and Partition Master can assign security codes to users.
• Users are identified by 2-digit user numbers and are pre-assigned to either
partition 1 or partition 2.
• Only the System Master can change user partitions.
• In addition to a security code, each user is assigned various system attributes.
• Security codes can be used interchangeably within a partition when performing
system functions (a system armed with one user's code can be disarmed by another
user's code), with the exception of the Guest code Arm Only code described below.
• Security code programming involves these steps:
1. Choose a user number from the set of users assigned to the partition in which
the user will be operating, and assign a 4-digit security code.
2. Assign an authority level to that user.
3. Assign other attributes as necessary (see attributes on the next page).
NOTE: The factory settings are designed to meet most normal user situations.
Therefore, the only step you usually need to do when adding users is assign a user
number (from the partition’s pre-assigned user numbers) and a security code.
Authority Level Definitions
Authority levels define the system functions a particular user can/cannot perform.
Level Title
Explanation
N/A
0
System Master
(default = 1234)
Reserved for user 02; Can perform all system functions and assign
codes in both partitions; can change its own code as follows:
Master code + [8] + 02 + new master code + new master code again
Standard User:
Can only perform security functions in assigned partition.
Cannot perform system functions reserved for the master user.
1
2
Arm Only:
Guest:
Can only arm the system. Cannot disarm or do other functions.
Can arm the system in assigned partitions, but cannot disarm the system
unless the system was armed with this code. This code is typically assigned
to someone (e.g., babysitter or cleaner) who has a need to arm/disarm the
system only at certain times. The user of this code should not use the “Quick
Arming” feature.
3
4
Duress Code:
Intended for use when you are forced to disarm or arm the system under
threat. When used, the system will act normally, but can silently notify the
Central Monitoring Station of your situation, if that service has been
provided.
Partition Master
Can do everything a standard user can do, and
can assign security codes to users in their partition.
– 32 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Security Codes & Authority Levels (cont’d)
How to Assign Security Codes and Attributes
The following lists the various command strings for adding security codes and attributes
Refer to the User Setup chart at the back of this manual for factory defaults of
user attributes and to keep a record of user programming.
NOTE: Partition Master codes apply only to those user numbers previously assigned (by the
system master/installer) to the partition master’s partition.
Add Security Code:
System/Partition Master code + [8] + user no. + new user’s security code
(Users 03/33 are preset
to partition programmers,
but can be changed.)
User 01 = installer
User 02 = master
The Keypad beeps once to confirm that new user was added.
User 03 = partition 1 master
User 33 = partition 2 master
Delete Security Code: System/Partition Master code + [8] + [user no.] + [#] [0]
The user code and all attributes* programmed for this user number,
including any associated RF keys, are erased from the system.
(*except assigned partition)
Authority Level:
System/Partition Master code + [8] + [user no.] + [#] [1]+ auth. level
Factory Defaults:
users 04-32/34-49 = 0
users 03/33 = 4
Authority Levels (see definitions on previous page):
0 = standard user
1 = arm only
2 = guest
3 = duress
4 = partition master
Access Group:
System/Partition Master Code + [8] + [user no.] + [#] [2]+ group (1-8)
Factory Defaults:: none
You can assign users to a group, then set an access schedule that
defines the times this group of users can operate the system. The
system ignores these users outside the scheduled times.
User’s Partition:
System Master Code + [8] + [user no.] + [#] [3] + [0] + partition(s) + [#]
This command assigns the partitions the user can access. If more
than one, enter partition numbers sequentially, then press [#] to end.
E.g., master code + [8] + [user no.] + [#] [3] + [0] + [1] [2] + [#] gives
the user access to partitions 1 and 2 and the common partition.
Partition Entries: 1 = partition 1 and common
Factory Defaults:
Part. 1 = users 03-32
Part. 2 = users 33-49
2 = partition 2 and common
3 = common partition only
RF User Number:
Master/Part. Prog. Code + [8] + [user no.] + [#] [4]+ zone no.
Factory Defaults:: none
Use this command to assign a wireless button device (keyfob) to this
user (keyfob must be enrolled in system first; see installer).
Zone number: enter the zone number assigned to a button on the
keyfob that will be used for arming/disarming by this user.
Pager On/Off:
Master/Part. Prog. Code + [8] + [user no.] + [#] [5] + 0 or 1
Factory Defaults:
users 01-49 = 1 (on)
You can program a user so that a message is sent to a pager
whenever this code is used to arm or disarm the system.
Paging On/Off: 1 = allow paging; 0 = no paging for this user
– 33 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessing Other Partitions
About Accessing Partitions
(GOTO Command and Multi-Partition Arming)
Each keypad is assigned a default partition for display purposes, and will show only
that partition's information.
• If the user is authorized, a keypad in one partition can be used to perform
system functions in the other partition by using the GOTO command. Refer to
the GOTO section.
• If the user is authorized, that user can arm other partitions. Refer to the Multi-
Partition Arming section.
The following table shows the relationship of the keypads in each partition when
system is armed and disarmed.
PARTITION 1
PARTITION 2
COMMON ZONE
(LOBBY, etc.)
Arming
State
Keypad
Status
Arming Keypad
Arming
State
Keypad
Status
State
Status
Disarmed
Partition 1
Disarmed
Partition 2
Disarmed Common Zone
Condition 1
Condition 2
Condition 3
Condition 4
Ö
Ö
Ö
Ö
Only
Only
Only
Disarmed Partition 1 and
Common Zone
Armed
Partition 2
Disarmed Common Zone
Only
Only
Armed
Partition 1
Disarmed Partition 2 and Disarmed Common Zone
Only
Common Zone
Only
Armed
Partition 1
Armed
Partition 2
Armed
Common Zone
Only
Only
Only
When both partitions are disarmed, the keypad in each partition displays zone
status for its partition only. The common zone keypad shows the status in that
zone only. See Condition 1 above.
When partition 1 is disarmed and partition 2 is armed, the keypad in partition 1
shows the status of partition 1 and the common zone. Partition 2 will display the
status of partition 2 only. See Condition 2 above.
When partition 1 is armed and partition 2 is disarmed, the keypad in partition 1
shows the status of partition 1 only. Partition 2 will display the status of partition
2 and the common zone. See Condition 3 above.
As long as any one of the two partitions is disarmed, the common zone will
always be disarmed. The common zone will be armed only when both
partition 1 and 2 are armed. See Condition 4 above.
– 34 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessing Other Partitions (cont’d)
Using the GoTo Command
If the user is authorized, a keypad in one partition can be used to perform system
functions in the other partition by using the GOTO command.
• You must use an Alpha keypad to access another partition.
• Keypads automatically return to their original partition after 30 seconds
with no keypad activity.
Alpha Display:
1.
+ [∗] + partition number (0,1,2,3)
(Security Code; only applies if user has access to other partitions)
1 DISARMED
READY TO ARM
0 = return to keypad’s original partition.
1 = partition 1; 2 = partition 2; 3 = common zone
The keypad beeps to confirm the partition change.
Fixed-Word Display: Green LED lit
2. The keypad remains in the new partition until
directed to go to another partition, or until it
automatically returns to the original partition.
Alpha Display:
2 DISARMED
READY TO ARM
The active partition number is displayed in the
upper left portion of screen, if the option is selected.
Fixed-Word Display: Green LED lit
Multi-Partition Arming
Some users can be given Multi-Partition arming ability by being assigned to both
partitions when programming user attributes.
When attempting to arm multi-partitions:
• You must use an Alpha keypad.
• The system arms only if all partitions are “ready to arm.”
• If any partition is “not ready,” the system does not arm at all.
• You can use the GOTO command to bypass open zones before arming.
• If any partition is already armed when global arming is attempted, that
partition remains in its existing armed state.
Alpha Display:
+ [0] + arm command (see list below)
(Security Code)
1 DISARMED
READY TO ARM
Multi-Partition Arming Commands
2 = arms all partitions AWAY
3 = arms all partitions STAY
Fixed-Word Display: Green LED lit
33 = arms all partitions NIGHT-STAY
4 = arms all partitions MAXIMUM
7 = arms all partitions INSTANT
1 = disarms all partitions
– 35 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Accessing Other Partitions (cont’d)
Common Zone Operation
Your system may have been set up to use a common zone, which is
an area shared by users of both partitions, such as a foyer or lobby.
If so, please note the following:
Ask your installer if a
"common zone" was
assigned. If so, check
this box
• The common zone will sound and report alarms only when both
partitions are armed. If only one partition is armed, the system
ignores faults on the common zone.
• Either partition may arm its system if the common zone is
faulted, but once armed, the other partition will not be able to
arm unless the common zone is first bypassed or the fault is
corrected.
• Faults on the common zone are displayed on common partition
keypads, and will also appear on another partition’s keypad when
the alternate partition is armed.
• Either partition can clear and restore the common zone after an
alarm.
• Entry/exit time for the common zone is the same as for partition 1.
– 36 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Scheduling
About Scheduling
The system provides to 16 end-user schedules (programmable by master/installer only),
which can control various types of events.
• Each schedule causes a defined event to start and stop (when appropriate) at a
specified time.
• Schedules can be set to automatically repeat at various intervals.
• Schedules can be set for random starting, if desired.
Creating Schedules
Alpha Displays:
1.
+ [#] + [6] [4]
1 DISARMED
READY TO ARM
(Master Code)
2. Enter a 2-digit schedule number from: 01-16.
Press [∗] to continue.
ENTER SCHED NO.
00=QUIT
00
3. Enter the desired 2-digit event number from the list:
00 = clear the scheduled event
ENTER EVENT
CLEAR EVENT 00
01 = turn a programmed output on or off
(see Using Device Commands section for a list of output device numbers
used in your system)
02 = set a user access schedule for one or more users
(see Security Codes section for an explanation of access groups)
03 = send a “latch-key” report to a pager if the system is not disarmed by a
specified time; message sent is “777-7777.”
04 = automatically arm the system in STAY mode at a specified time
05 = automatically arm the system in AWAY mode at a specified time
06 = automatically disarm the system at a specified time
07 = Display the word “REMINDER” at a specified time (if selected, the keypad
beeps every 30 seconds beginning when the word “REMINDER” is first
displayed, and the display alternates with the normal keypad display about
every 4-5 seconds. To stop the beeps and cancel the display once it starts,
press any key).
Press [∗] to continue.
4. For event number “01,” enter the output number
RELAY NUMBER
associated with this schedule.
00
Otherwise, this prompt is skipped.
Press [∗] to continue to the “Start” prompt shown on
the next page.
– 37 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Scheduling (cont’d)
5. For event number “02,” enter the access group
number. Otherwise, this prompt is skipped.
Press [∗] to continue to the “Start” prompt below.
6. For event numbers “03-07,” enter the partition
number to be armed or disarmed.
0 = arm all; 1 = partition 1; 2 = partition 2;
3 = arm common
GROUP NUMBER
PARTITION
X
X
Otherwise, this prompt is skipped.
Press [∗] to continue to the “Start” prompt.
7. Enter the event’s start time and days of week.
Hour = 00-12; minute = 00-59
START
SMTWTFS
AM = 0; PM = 1
HH:MMAM 1000000
Days = Position the cursor under the desired days
using the [∗] key to move forward, then press “1” to
select the day.
Press [∗] to continue.
8. If applicable, enter the event’s stop time and days of
week (applies only to event numbers 01, 02, and 03).
Refer to step 7 for available entries.
STOP
SMTWTFS
HH:MMAM 1000000
Press [∗] to continue.
9. Enter the desired repeat option.
0 = no repeat
REPEAT OPTION
0-4
X
1 = repeat schedule weekly
2 = repeat schedule biweekly (every other week)
3 = repeat schedule every third week
4 = repeat schedule every fourth week
e.g., To make a schedule that happens everyday you
would select all days with a repeat count of 1. To
make a schedule that runs for one week then stops,
select everyday with a repeat count of 0.
10. For event number 01 (output on/off), select the
randomize option, if desired.
RANDOMIZE
0=NO 1=YES
X
0 = no; 1 = yes
If selected, the schedule times will vary within 60
minutes of the “hour” time. For example, if a
schedule is set to start at 6:15pm, it will do so the
first time 6:15pm arrives, but on subsequent days it
will start anytime between 6:00 and 6:59 p.m.
Press [∗] to continue.
– 38 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Event Logging Procedures
About Event Logging
The system records various events in a history log, which can be viewed by the master
user on an Alpha Display keypad.
• The Event Log holds up to 100 events.
• Events are displayed in chronological order, from most recent to oldest.
• When the log is full, the oldest event is replaced by the logging of any new event.
Viewing the Event Log
Alpha Displays:
1.
+ [#] + [6] + [0]
(Master Code)
∗∗∗∗DISARMED∗∗∗∗
READY TO ARM
2. The system displays the most recent event as follows:
• event number
001 E441 U001 P1
12:34AM 01/02/00
• type of event, identified by its corresponding code
(refer to the code table that follows)
• zone or user number (depending on type of event)
• partition in which event occurred
• time and date of the event’s occurrence.
3. Pressing [∗] displays previous events (back in time).
Pressing [#] displays events forward in time.
4. Exit the event log by pressing any key other than [∗]
or [#].
Understanding the Type of Event Displayed
If the event code is preceded by an E (as in the above display), it means that the
event is new and ongoing; if preceded by an R, it means the event has been restored.
Code
110
121
122
123
Definition
Code
131
132
134
135
Definition
Fire Alarm
Alarm, Perimeter
Alarm, Interior
Alarm, Entry/Exit
Alarm, Day/Night
Duress
Alarm, 24-hour Silent
Alarm, 24-hour Audible
– 39 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Event Logging Procedures (cont’d)
Code
143
145
146
150
Definition
Alarm, Expansion Module
ECP Module cover tamper
Silent Burglary
Code
Definition
401
Disarmed, Armed AWAY,
Armed MAXIMUM
Alarm, 24-Hour Auxiliary/Monitor
zone
403
406
407
Schedule Arm/Disarm AWAY
Cancel by User
162
301
302
305
321
333
Carbon Monoxide
Remote Arm/Disarm
(Downloading)
AC Power
Low System Battery/Battery Test Fail
System Reset (Log only)
Bell/Siren Trouble
408
409
441
Quick Arm AWAY
Keyswitch Arm/Disarm AWAY
Disarmed/Armed
STAY/INSTANT,
Quick-Arm STAY/INSTANT
Trouble, Expansion Mod.
Supervision
442
459
570
601
602
606
607
623
625
Keyswitch Arm/Disarm STAY
Recent Closing
339 (803) GSM Module Power-On Reset
341
344
Trouble, ECP Cover Tamper
RF Receiver Jam
Bypass
Manually Triggered Dialer Test
Periodic Test
350 (951) Ethernet Communication Path
Failure
350 (952) GSM Communication Path Fail
AAV to Follow
351
353
354
373
374
380
381
382
383
384
393
Telco Line Fault
Walk Test Entered/Exited
Event Log 80% Full
Long Range Radio (GSM) Trouble
Comm Fail (log only)
Fire Loop Trouble
Real-Time Clock was Changed
(log only)
627
628
642
Program Mode Entry (log only)
Program Mode Exit (log only)
Latch Key (log only)
Exit Error Alarm
Global Trouble, Trouble Day/Night
RF Supervision Trouble
Supervision Auxiliary Wire Zone
RF Sensor Tamper
750 -789 Reserved for Configurable Zone
Type report codes (check with
central station when using these
codes)
RF Sensor Low-battery
Clean Me
NOTE: Ask your installer to explain the meaning of any code you do not understand.
– 40 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing the System
About Testing the System
Using the Test mode allows each protection point to be checked for proper operation.
Testing should be conducted weekly to ensure proper operation.
• The keypad sounds a single beep about every 30 seconds as a reminder that the
system is in the Test mode.
• Alarm messages are not sent to your Central Station while Test mode is on.
Alpha Displays:
1. Disarm the system and close all protected windows,
doors, etc. The READY indicator light should come on
if all zones are intact (i.e., all protected windows,
doors, etc. are closed.
∗∗∗∗DISARMED∗∗∗∗
READY TO ARM
2.
+ 5 TEST then [0] (walk)
1 = DIAL, 0 = WALK
(Master Code)
The Dial test (option “1”) is intended for the installer
and should not be used unless directed to do so by your
Security System Representative.
3. Listen. The external sounder should sound for about 1
second then turn off. If the sounder does not sound,
CALL FOR SERVICE. The “Test in Progress” display
appears only on the keypad that started the test.
TEST IN PROGRESS
4. Fault zones. Open each protected door and window in turn and listen for three
beeps from the keypad. Identification (zone number or zone description) of each
faulted protection point should appear on the display. The display clears when the
door or window is closed.
5. Walk in front of any interior motion detectors (if used) and listen for three beeps.
The identification of the detector should appear on the display when it is activated.
The display clears when no motion is detected. Note that if wireless motion detectors
are used, there is a 3-minute delay between activations. This conserves battery life.
6. Test all smoke detectors, following the manufacturer's instructions. The
identification of each detector should appear on the display when each is activated.
If a problem is experienced with any protection point (no confirming sounds, no
display), call for service immediately.
When all protection points have been checked and are intact (closed), there should
be no zone identification numbers displayed on the keypad.
7. Exit test mode:
+
1
OFF
(Security Code)
If the test mode is inadvertently left active, it automatically turns off after 4 hours.
During the final five minutes, the keypad will emit a double beep every 30 seconds.
– 41 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Trouble Conditions
"Check" and
"Battery" Displays
The word CHECK on the keypad's display, accompanied by a
"beeping" at the keypad, indicates a trouble condition in the system.
To silence the beeping for these conditions, press any key.
1. A display of "CHECK" and one or more zone numbers
indicates that a problem exists with the displayed zone(s) and
requires your attention. Determine if the zone(s) displayed are
intact and make them so if they are not. If the problem has been
corrected, the display can be cleared if you enter the OFF
sequence (security code plus OFF key) twice. If the display
persists, CALL FOR SERVICE.
Note: A display of CHECK 70 on Alpha Display keypads
indicates that the wiring connection to the external sounder is
at fault (opened or shorted), and you should CALL FOR
SERVICE. See “BELL FAILURE” on next page. A display of
CHECK 90 indicates that RF interference may be impeding the
operation of wireless sensors* in the system. See “Rcvr Jam”
on next page.
2. If there are wireless sensors* in your system, the CHECK
condition may also be caused by some change in the
environment that prevents the wireless receiver from receiving
messages from a particular sensor. CALL FOR SERVICE if this
occurs.
*
Not all systems use wireless sensors.
IF YOU CANNOT CORRECT A "CHECK" DISPLAY,
CALL FOR SERVICE.
TYPICAL "CHECK" DISPLAYS
AC
06
C H E C K 0 6
B E D R O O M W I N D O W
CHECK
ALPHA DISPLAY KEYPAD
FIXED-WORD DISPLAY KEYPAD
– 42 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Trouble Conditions (cont’d)
Words or letters in parentheses ( ) are those that are displayed on Fixed-Word Display
keypads.
COMM. FAILURE
(or FC)
Indicates that a failure has occurred in
the telephone communication portion of
your system. CALL FOR SERVICE.
Other Trouble
Displays
SYSTEM LO BAT
(or BAT with no
zone No.)
Indicates that a low system battery
condition exists. Display is
accompanied by "beeping"* at the
keypad. If this condition persists for
more than one day (with AC present),
CALL FOR SERVICE.
* Any “beeping” that
accompanies a
trouble display can
be stopped by
depressing any key
on the keypad or by
entering an OFF
sequence (code +
OFF)
LO BAT
Indicates that there is a low battery
condition in the wireless transmitter**
number displayed (00 is RF keypad).
+ zone descriptor
(or BAT with
zone No.)
*
Accompanied by a single "beep" (about
once every 30 seconds) at the keypad.
** Not all systems use
wireless sensors.
Either replace the battery yourself, or
CALL FOR SERVICE. If the battery is
not replaced within 30 days, a CHECK
display may occur.
Rcvr Jam
(or CHECK 90)
Wireless part of the system is experiencing
RF interference which may impede
reception from wireless sensors.**
Indicates a communication problem
between the control and a connected
device (e.g., RF receiver, zone expander)
where the “xx” indicates the device
address. CALL FOR SERVICE.
ALARM 1xx
FAULT 1xx
CHECK 1xx
(or 91)
Indicates that the control is on-line with
the Central Monitoring Station's remote
computer.
MODEM COMM
(or CC)
The control will not report system
activity while on-line. Wait a few minutes
— the display should disappear.
BELL FAILURE
(or CHECK 70)
Indicates that the wiring connection to
the external sounder is at fault (open or
shorted). Accompanied by “beeping” at
the keypad. CALL FOR SERVICE.
– 43 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Trouble Conditions (cont’d)
Other Trouble
Displays
(Continued)
AC LOSS
(or NO AC)
The system is operating on battery power
only due to an AC power failure.
If only some lights are out on the
premises, check circuit breakers and
fuses and reset or replace as necessary.
If AC power cannot be restored and a
“low system battery” message appears
(see previous page), CALL FOR
SERVICE.
If this message remains displayed for
more than 1 minute, system is disabled.
CALL FOR SERVICE.
Busy-Standby
(or dI)
OPEN CIRCUIT
(or OC)
The keypad is not receiving signals from
the control. CALL FOR SERVICE.
Long Rng Trbl
(or bF)
If part of your system, back-up Long
Range Radio communication has failed.
CALL FOR SERVICE.
TELCO FAULT
(or CHECK 94)
The telephone line has a problem.
CALL FOR SERVICE.
If there is no keypad display at all, and the READY indicator is not
lit, operating power (from AC and back-up battery) for the system
has been interrupted and the system is inoperative. CALL FOR
SERVICE.
Total Power Failure
In The Event Of Telephone Operational Problems
In the event of telephone operational problems, disconnect the control from the phone line by
removing the plug from the phone wall jack. We recommend that your installer demonstrate this
disconnection on installation of the system. Do not attempt to disconnect the phone connection
inside the control. Doing so will result in the loss of your phone lines. If the regular phones work
correctly after the control has been disconnected from the phone wall jack, the control has a
problem and you should immediately call for service. If upon disconnection of the control, there is
still a problem on the phone line, notify the Telephone Company that they have a problem and
request prompt phone repair service. The user may not under any circumstances attempt any
service or repairs to the security system. Repairs must be made only by authorized service (see
the LIMITED WARRANTY statement for information on how to obtain service).
– 44 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Maintaining Your System
The components of your security system are designed to be as
maintenance-free as possible. However, to make sure that your
system is in reliable working condition, do the following:
1. Test your system weekly.
Taking Care of
Your System
2. Test your system after any alarm occurs.
Silencing Low
Battery Warning
Tones at the
Keypad
You can silence the keypad’s warning tones by pressing the OFF key,
but the keypad's low battery message display will remain on as a
reminder that you have a low battery condition in one or more of your
wireless sensors. When you replace the weak battery with a fresh one,
the sensor sends a "good battery" signal to the control as soon as the
sensor is activated (opening/closing of door, window, etc.), causing the
low battery display to turn off. If the sensor is not activated, the
display will automatically clear within approximately 1 hour.
Each wireless sensor in your system has a 9-volt or 3-volt battery.
The system detects a low battery in wireless sensors, including smoke
detectors, the personal emergency transmitter, and the portable
wireless keypad and displays a low battery message*. (A low battery
in a portable wireless keypad is detected as soon as one of its keys is
pressed, and displayed as 00.). Battery-operated smoke detectors with
a low battery also emit a single "chirp" sound approximately once
every 20–30 seconds.
Replacing
Batteries in
Wireless Sensors
Wireless sensors
may not have
been used in your
security system
Alkaline batteries provide a minimum of 1 year of operation, and in
most units and applications, provide 2–4 years of service. 3-volt
lithium batteries provide up to 4 or more years of operation. Actual
battery life will depend on the environment in which the sensor is
used, the number of signals that the transmitter in the sensor has had
to send, and the specific type of sensor. Factors such as humidity, high
or low temperatures or large swings in temperature, may all lead to
the reduction of actual battery life in an installation.
IMPORTANT:
Use only batteries
recommended by
your installer as
replacement.
* The low battery message comes on as a warning that battery replacement
in indicated sensor(s) is due within 30 days. In the meantime, a sensor
causing a low battery indication is still fully operational.
• Treat the components of your security system as you would any
other electrical equipment. Do not slam sensor-protected doors or
windows.
Routine Care
• Keep dust from accumulating on the keypad and all protective
sensors, particularly on motion sensors and smoke detectors.
• The keypad and sensors should be cleaned carefully with a dry soft
cloth. Do not spray water or any other fluid on the units.
– 45 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Fire Alarm System
THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS
Your fire alarm system (if installed) is on 24 hours a day, for
continuous protection. In the event of an emergency, the strategically
located smoke and heat detectors will sound their alarms and
automatically send signals to your system, triggering a loud,
interrupted pulsed sound* from the Keypad(s) and any external
sounders. A FIRE message will appear at your Keypad and remain on
until you silence the alarm (see below for silencing fire alarms).
General
* Temporal pulse sounding is produced for Fire alarms, as follows:
3 pulses–pause–3 pulses–pause–3 pulses–pause. . . , repeated.
TYPICAL FIRE EMERGENCY DISPLAYS
AC
F I R E 0 1
M A S T E R
01
ALARM
FIRE
B E D R O O M
ALPHA DISPLAY KEYPAD
FIXED-WORD DISPLAY KEYPAD
1. You can silence the alarm at any time by pressing the OFF key
(the security code is not needed to silence fire alarms). To clear the
display, enter your code and press the OFF key again (to clear
Memory of Alarm).
Silencing
Fire Alarms and
Clearing Memory
of Alarm
2. If the Keypad's FIRE display does not clear after the second OFF
sequence, smoke detectors may still be responding to smoke or
heat producing objects in their vicinity. Investigate, and should
this be the case, eliminate the source of heat or smoke.
3. If this does not remedy the problem, there may still be smoke in
the detector. Clear it by fanning the detector for about 30 seconds.
When the problem has been corrected, clear the display by
entering your code and pressing the OFF key.
Depending on the type of smoke detectors in your system, it may be
necessary to "reset" the smoke detectors after a fire alarm has been
turned off. Check with your installer. This "reset" is accomplished at
a keypad, as follows:
Smoke Detector
Reset
Enter Security Code ( except “arm only” user), then press the [1] key.
NOTE: During smoke detector reset, “FAULT xx” appears (about six
seconds) and should disappear if the detector is clear.
– 46 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Fire Alarm System (cont’d)
THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS
1. Should you become aware of a fire emergency before your smoke or
heat detectors sense the problem, go to your nearest keypad and
manually initiate an alarm by pressing the panic key assigned for
FIRE emergency for 2 seconds (see below). If a key pair has been
assigned for fire, press both keys at the same time. See the Using
the Panic Keys section below for further details.
Manually
Initiating
a Fire Alarm
2. Evacuate all occupants from the premises.
3. If flames and/or smoke are present, leave the premises and notify
your local Fire Department immediately.
4. If no flames or smoke are apparent, investigate the cause of the
alarm. The zone number(s) of the zone(s) in an alarm condition will
be displayed at the keypad.
A key or key pair may have been assigned for manually initiating a
FIRE alarm. See the Panic Keys section for key assignments.
For convenience, indicate the key or key pair assigned for fire below.
Individual Keys
Using the
Panic Key(s)
Assigned for
FIRE
Emergency
A
B
C
Press the individual key assigned for fire for 2 seconds.
OR Key Pairs
1 OFF
∗ READY
and
(zone 95)
(zone 99)
(zone 96)
Press both keys of the
key pair assigned for
fire at the same time.
#
#
∗ READY
and
and
3 STAY
DISPLAYS FOLLOWING MANUAL INITIATION OF A FIRE ALARM
AC
F I R E 9 5
95
ALARM
FIRE
ALPHA DISPLAY KEYPAD
FIXED-WORD KEYPAD
If installed, carbon monoxide detectors provide continuous protection.
If a high level of carbon monoxide is detected, an interrupted pulsed
alarm sound occurs at the keypads and the detector(s). Immediately
move to a spot where fresh air is available, preferably outdoors. From
a safe area, call your security service provider for further instructions.
To silence the keypad sounding, press the OFF key. To silence the
detector, see its instructions.
Carbon
Monoxide
Alarms
– 47 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Fire Alarm System (cont’d)
THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS
National Fire Protection Association
Recommendations on Smoke Detectors
With regard to the number and placement of smoke/heat detectors, we
subscribe to the recommendations contained in the National Fire Protection
Association's National Fire Alarm Code (NFPA 72) noted below.
Early warning fire detection is best achieved by the installation of fire
detection equipment in all rooms and areas of the household as follows: A
smoke detector installed outside of each separate sleeping area, in the
immediate vicinity of the bedrooms and on each additional story of the
family living unit, including basements and excluding crawl spaces and
unfinished attics.
In addition, the NFPA recommends that you install heat or smoke detectors
in the living room, dining room, bedroom(s), kitchen, hallway(s), attic,
furnace room, utility and storage rooms, basements and attached garages.
KITCHEN
KITCHEN
LIVING ROOM
BDRM
DINING
BEDROOM
BEDROOM
TV ROOM
DINING
BDRM
BEDROOM
BEDROOM
LIVING ROOM
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
BEDROOM
TO
BR
BEDROOM
BEDROOM
KTCHN
GARAGE
CLOSED
DOOR
LVNG RM
.
BASEMENT
floor_plan-001-V1
– 48 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Fire Alarm System (cont’d)
THIS SECTION APPLIES ONLY TO RESIDENTIAL SYSTEMS
Emergency Evacuation
Establish and regularly practice a plan of escape in the
event of fire. The following steps are recommended by
the National Fire Protection Association:
1. Position your detector or your interior and/or
exterior sounders so that they can be heard by all
occupants.
2nd FLOOR
2. Determine two means of escape from each room.
One path of escape should lead to the door that
permits normal exit from the building. The other
BACK DOOR
may be a window, should your path be impassable.
Station an escape ladder at such windows if there
is a long drop to the ground.
1st FLOOR
3. Sketch a floor plan of the building. Show windows,
doors, stairs and rooftops that can be used to
escape. Indicate escape routes for each room. Keep
these routes free from obstruction and post copies
of the escape routes in every room.
4. Assure that all bedroom doors are shut while you
BACK
are asleep. This will prevent deadly smoke from
entering while you escape.
5. Try the door. If the door is hot, check your
alternate escape route. If the door is cool, open it
cautiously. Be prepared to slam the door if smoke
or heat rushes in.
FRONT
6. When smoke is present, crawl on the ground. Do
not walk upright, since smoke rises and may
overcome you. Clearer air is near the floor.
7. Escape quickly; don't panic.
8. Establish a common meeting place outdoors, away
from your house, where everyone can meet and
then take steps to contact the authorities and
account for those missing. Choose someone to
assure that nobody returns to the house — many
die going back.
– 49 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Guide to Basic System Functions
FUNCTION
PROCEDURE
COMMENTS
Press READY key.
View faulted zones when system not
ready.
Check Zones
Enter code. Press arming key desired:
Arms system in mode selected.
Arm System
(AWAY, STAY, NIGHT-STAY, MAXIMUM,
INSTANT)
Press #. Press arming key desired:
(AWAY, STAY, MAXIMUM, INSTANT)
Arms system in mode selected, quickly
and without use of a code.
Quick Arm
(if programmed)
Enter code. Press BYPASS [6] key.
Enter zone number(s) to be bypassed
(use 2-digit entries).
Bypassed zones are unprotected and
will not cause an alarm if violated.
Bypass Zone(s)
Enter code. Press BYPASS [6] key + [#].
Bypasses all faulted zones
automatically.
Quick Bypass
(if programmed)
Silence Sounders
Burglary:
Enter code. Press OFF [1] key.
Press OFF [1] key.
Also disarms system. Memory of alarm
remains until cleared.
Memory of Alarm remains until
cleared.
Fire or CO:
"Check":
Press any key.
Determine cause.
Enter code. Press OFF [1] key. (OFF need
Also silences sounders. Memory of
Disarm System
not be pressed if entry delay or an alarm is alarm remains until cleared.
active)
Clear Alarm
Memory
After disarming, enter code again.
Press OFF [1] key again.
Keypad beeps rapidly on entry if alarm
has occurred while absent. Alarm
display will remain upon disarming
until cleared.
Duress (if active
and connected to
Central Station)
Arm or disarm "normally," but use your 4-
digit Duress code to do so.
Performs desired action and sends
silent alarm to Central Station.
Press key [A], [B], or [C] for at least 2
seconds, or key pairs 1 + ✱; ✱ + #, or 3 + #
respectively.
See the Panic Keys section for
emergency functions programmed for
your system. Note: Keys “A”, “B”, and
“C” may have been programmed for
other functions.
Panic Alarms
(as programmed)
To turn ON or OFF: Enter code. Press
CHIME key.
The keypad will sound if doors or
windows are violated while system is
disarmed and chime mode is ON.
Chime Mode
Test Mode
To turn ON: Enter code. Press TEST key,
then [0].
Tests alarm sounder and allows
sensors to be tested.
To turn OFF: Enter code. Press OFF key.
Phone Access
if applicable
Consult Phone Access User's Guide that
accompanies the Phone Module.
Permits system access remotely, via
Touch-tone phone.
– 50 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Summary of Audible/Visual Notifications
Fixed-Word Display Keypads
SOUND
CAUSE
DISPLAY
LOUD,
FIRE ALARM or CO ALARM (CO:
FIRE or ALARM (for CO) is displayed; zone
* keypad/detector only; not external number of zone in alarm is displayed. If a fire
INTERRUPTED
Keypad & Ext.
sounder)
alarm is manually activated, zone number 95
will be displayed.
LOUD,
CONTINUOUS
Keypad & Ext.
BURGLARY/AUDIBLE
EMERGENCY ALARM
ALARM is displayed. Zone number of zone
in alarm is also displayed.
*
ONE SHORT
BEEP
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT b. Number of the open protection zone
a. READY indicator light comes on.
(not repeated)
Keypad only
WITH AN OPEN ZONE
displayed.
c. Zone numbers of the bypassed protection
zones are displayed (one beep is heard for
each zone displayed). Subsequently,
BYPASS is displayed.
c. BYPASS VERIFY
ONE SHORT
BEEP
(once every 40
secs)
a. SYSTEM IS IN TEST MODE
b. LOW BATTERY AT A
TRANSMITTER
c. SYSTEM WILL AUTOARM
WITHIN 10 MINUTES
a. Opened zone numbers will appear.
b. BAT displayed with zone number of
transmitter.
c. No special display.
Keypad only
TWO SHORT
BEEPS
ARM AWAY or MAXIMUM
AWAY is displayed. Red ARMED indicator is
lit.
Keypad only
THREE SHORT a. ARM STAY, NIGHT-STAY,
a. STAY or INSTANT is displayed. Red
ARMED indicator is lit.
BEEPS
INSTANT
Keypad only
b. ZONE OPENED WITH
SYSTEM IN CHIME MODE
b. CHIME displayed; zone number of open
protection zone will be displayed if the [✱]
key is pressed.
RAPID
BEEPING
Keypad only
a. TROUBLE
a. CHECK displayed. Zone number of
troubled protection zone is displayed.
b. FIRE or ALARM is displayed; zone
number of zone in alarm is displayed
c. BAT displayed with no zone ID number.
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY
d. EXT. SOUNDER WIRING
FAIL
d. CHECK 70 is displayed.
e. LAST 10 SEC of EXIT DELAY
e. No special display.
SLOW
BEEPING
Keypad only
a. EXIT DELAY WARNING
b. ENTRY DELAY WARNING
a. AWAY is displayed.
b. Exceeding the entry delay time without
disarming causes alarm.
*
If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
– 51 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Summary of A/V Notifications (cont’d)
Alpha Display Keypads
SOUND
CAUSE
DISPLAY
LOUD,
INTERRUPTED*
Keypad & Ext.
FIRE ALARM or CO ALARM
(CO: keypad/detector only; not
external sounder)
FIRE or ALARM (for CO) is displayed; descriptor
of zone in alarm is displayed. If a fire alarm is
manually activated, zone number 95 will be
displayed.
LOUD,
BURGLARY/AUDIBLE
ALARM is displayed. If programmed, descriptor
CONTINUOUS* EMERGENCY ALARM
Keypad & Ext.
of zone in alarm is also displayed
a. DISARMED/READY TO ARM is displayed.
b. Number and descriptor of open protection zone
is displayed.
c. Numbers and descriptors of the bypassed zones
are displayed (One beep is heard for each zone
displayed). Then, the following is displayed:
DISARMED BYPASS /Ready to Arm.
ONE SHORT
BEEP
(not repeated)
Keypad only
a. SYSTEM DISARM
b. SYSTEM ARMING ATTEMPT
WITH AN OPENZONE
c. BYPASS VERIFY
ONE SHORT
BEEP
(once every 40
seconds)
a. SYSTEM IS IN TEST MODE a. Opened Zone identifications will appear.
b, LOW BATTERY AT A
TRANSMITTER
b. LO BAT displayed with description of
transmitter.
c. SYSTEM WILL AUTOARM
WITHIN 10 MINUTES
c. No special display.
Keypad only
TWO SHORT
BEEPS
ARM AWAY or MAXIMUM
ARMED AWAY or MAXIMUM displayed. Red
ARMED indicator lit.
Keypad only
THREE SHORT a. ARM STAY, NIGHT-STAY,
a. ARMED STAY or ARMED INSTANT
BEEPS
OR INSTANT
displayed. Red ARMED indicator lit.
Keypad only
b. CHIME displayed, descriptor of open
protection zone will be displayed if the [✱] key
is pressed.
b. ZONE OPENED WHILE
SYSTEM IS DISARMED
a. CHECK displayed. Descriptor of troubled
protection zone is displayed.
b. FIRE or ALARM is displayed; descriptor of
zone in alarm is displayed.
c. SYSTEM LO BAT displayed.
d. BELL FAILURE is displayed.
e. No special display.
RAPID
BEEPING
Keypad only
a. TROUBLE
b. MEMORY OF ALARM
c. SYSTEM LOW BATTERY.
d. EXT. SOUNDER WIRE FAIL
e. LAST 10 SEC of EXIT DELAY
SLOW
BEEPING
a. EXIT DELAY WARNING (if
programmed).
a. ARMED AWAY or MAXIMUM is displayed
along with You May Exit Now.
Keypad only
b. DISARM SYSTEM OR ALARM WILL
OCCUR is displayed. Exceeding the delay
time without disarming causes an alarm.
b. ENTRY DELAY WARNING.
* If a bell is used as external sounder, fire alarm is pulsed ring; burglary/audible emergency is steady ring.
– 52 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Statements and Warnings
FEDERAL COMMUNICATIONS COMMISSION (FCC) PART 15 STATEMENTS
The user shall not make any changes or modifications to the equipment unless authorized by the Installation
Instructions or User's Manual. Unauthorized changes or modifications could void the user's authority to
operate the equipment.
CLASS B DIGITAL DEVICE STATEMENT
NOTE: This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference in a residential installation. This equipment generates, uses and can radiate radio
frequency energy and, if not installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that interference will not occur in a
particular installation. If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference
by one or more of the following measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for help.
INDUSTRY CANADA (IC) STATEMENTS
This device complies with RSS210 of Industry Canada. Operation is subject to the following two conditions: (1)
This device may not cause harmful interference, and (2) This device must accept any interference received,
including interference that may cause undesired operation.
This Class B digital apparatus complies with Canadian ICES-003.
Cet appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
TELEPHONE/MODEM INTERFACE
FCC Part 68
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that
contains the FCC registration number and Ringer Equivalence Number (REN). You must provide this
information to the telephone company when requested.
This equipment uses the following USOC jack: RJ31X
This equipment may not be used on telephone-company-provided coin service. Connection to party lines is
subject to state tariffs. This equipment is hearing-aid compatible.
Industry Canada
NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the
equipment meets telecommunications network protective, operational and safety requirements as prescribed
in the appropriate Terminal Equipment Technical Requirements document(s). The Department does not
guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of
the local telecommunications company. The equipment must also be installed using an acceptable method of
connection. The customer should be aware that compliance with the above conditions may not prevent
degradation of service in some situations.
– 53 –
Download from Www.Somanuals.com. All Manuals Search And Download.
Regulatory Statements (cont’d)
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any
repairs or alterations made by the user to this equipment, or equipment malfunctions, may give the
telecommunications company to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if present, are connected together, This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves but should contact appropriate
electric inspection authority, or electrician, as appropriate.
Ringer Equivalence Number Notice:
The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the
maximum number of terminals allowed to be connected to a telephone interface. The termination on an
interface may consist of any combination of devices subject only to the requirement that the sum of the
Ringer Equivalence Numbers of all the devices does not exceed 5.
Industrie Canada
AVIS: l’étiquette d’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel
est conforme aux normes de protection, d’exploitation et de sécurité des réseaux de télécommunications,
comme le prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le
Ministère n’assure toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur.
Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de
l’enterprise locale de télécommunication. Le matériel doit également être installé en suivant une méthode
acceptée da raccordement. L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions
énoncées ci-dessus n’empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le
fournisseur. L’entreprise de télécommunications peut demander à l’utilisateur da débrancher un appareil à
la suite de réparations ou de modifications effectuées par l’utilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise à la terre de la source d’energie
électrique, de lignes téléphoniques et des canalisations d’eau métalliques, s’il y en a, sont raccordés
ensemble. Cette précaution est particulièrement importante dans les régions rurales.
Avertissement : L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à
un service d’inspection des installations électriques, ou à un électricien, selon le cas.
AVIS : L’indice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le
nombre maximal de terminaux qui peuvent être raccordés à une interface. La terminaison d’une interface
téléphonique peut consister en une combinaison de quelques dispositifs, à la seule condition que la somme
d’indices d’équivalence de la sonnerie de tous les dispositifs n’excède pas 5.
– 54 –
Download from Www.Somanuals.com. All Manuals Search And Download.
System Features Log
Features
Comments
Part. 1:
Part. 1:
Part. 1:
Zones:
yes
Exit Delay
Part. 2:
Part. 2:
Part. 2:
Entry Delay 1
Entry Delay 2
NIGHT-STAY Zones
Quick Arm
no
no
Quick Bypass
Automatic Paging
yes
yes
no
users:
flash
flash
Keyswitch Arming
(circle type of LED lighting)
Arm AWAY: steady
Arm STAY: steady
Function Keys
A
B
C
D
Comments
• Single-Button Arming
• Step Arming
• Paging (see Paging chart)
• Time/Date Display
• Macro Key 1
• Macro Key 2
• Macro Key 3
• Macro Key 4
• Emergency Key**: Personal
• Emergency Key**: Silent Alarm
• Emergency Key**: Audible Alarm
• Emergency Key**: Fire
• Device Activation
Device:
** Emergency Keys:
A = [1] / [∗]
B = [∗] / [#]
C = [3] / [#]
– 55 –
Download from Www.Somanuals.com. All Manuals Search And Download.
System Features Log (cont’d)
User Setup
The following chart will help keep track of system users. Copies should be distributed to the
partition 1 and partition 2 (if applicable) masters for their records.
To program a user attribute:
Enter system/partition* master code + [8] + user no. + “#” command listed in column heading.
User
No.
User
Name
User’s Part(s).
(system master only)
[#] [3] + part(s) + [#]
Security
Code
Auth.
Level
Access
Group
RF Zone
Number
Pager
on/off
enter new code [#] [1] + level
[#] [2] + group [#] [4] + zone no. [#] [5] + 0/1
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
32
installer
system master
partition 1 master
(all)
(all)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
installer
master
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(4)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
– 56 –
Download from Www.Somanuals.com. All Manuals Search And Download.
System Features Log (cont’d)
User Setup (cont’d)
Enter system/partition master code + [8] + user no. + “#” command listed in column heading.
User
User
Name
User’s Part(s).
(system master only)
[#] [3] + part(s) + [#]
Security
Code
Auth.
Level
Access
Group
RF Zone
Number
Pager
on/off
*
No.
enter new code [#] [1] + level
[#] [2] + group [#] [4] + zone no. [#] [5] + 0/1
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
partition 2 master
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(2)
(4)
(1)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(0)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
(1)
Authority Levels: 0 = standard user
1 = arm only
Partitions:0 = clears partition 1 and partition 2 defaults
1 = partition 1 and common
2 = guest
2 = partition 2 and common
3 = duress
4 = partition master
3 = common partition only
Paging: 0 = no paging; 1 = allow paging
Paging Setup
Automatically Reports Upon…
open/close alarm/trouble zone list
p1 p2 p1 p2 p1 p2
Sched. Func. Key
Pager Phone Number\
Pager Prefix Characters
1
2
3
4
– 57 –
Download from Www.Somanuals.com. All Manuals Search And Download.
System Features Log (cont’d)
Schedules*: master code + [#] + [6] [4]
No.
Event
Device No.
Group No. Partition
Start
Stop
Time/
Day
Repeat Random
(see list below) for “01” events:
for “02” events: for “04-06” events: Time/
(1-4)
(yes/no)
(see device list below) enter 1-8
enter 1, 2, or 3
Day
01
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
Events:
00 = clear event
01 = device on/off
02 = user access
03 = latch key report
04 = forced STAY arm
05 = forced AWAY arm
06 = auto disarm
07 = display “reminder”
Repeat Options: 0 = none; 1 = repeat weekly; 2 = repeat every other week; 3 = repeat every third week; 4 = repeat every fourth week
List of Output Devices
Device
01
Description
Schedule No.
Function Key
02
03
04
05
06
07
08
09
10
11
12
13
14
15
16
17
18
– 58 –
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S INSURANCE PREMIUM CREDIT REQUEST
This form should be completed and forwarded to your homeowner’s insurance carrier for possible
premium credit.
A. GENERAL INFORMATION:
Insured’s Name and Address:
Insurance Company:
Policy No.:
VISTA-21iP / VISTA-21iPSIA________________________________________________ Other
(circle the appropriate model number)
Type of Alarm:
Installed by:
Burglary
Fire
Both
Serviced by:
Name
Name
Address
Address
B. NOTIFIES (Insert B = Burglary, F = Fire)
Local Sounding Device
Police Dept.
Fire Dept.
Central Station
Name:
Address:
Phone:
C. POWERED BY: A.C. With Rechargeable Power Supply
D. TESTING: Quarterly Monthly Weekly
Other
continued on other side
– 59 –
Download from Www.Somanuals.com. All Manuals Search And Download.
OWNER’S INSURANCE PREMIUM CREDIT REQUEST
(cont.)
E. SMOKE DETECTOR LOCATIONS
Furnace Room
Kitchen
Bedrooms
Attic
Hall
Basement
Living Room
Dining Room
F. BURGLARY DETECTING DEVICE LOCATIONS:
Front Door
Basement Door
Rear Door
All Exterior Doors
1st Floor Windows
All windows
Interior locations
All Accessible Openings, Including Skylights, Air Conditioners and Vents
G. ADDITIONAL PERTINENT INFORMATION:
Signature:
Date:
– 60 –
Download from Www.Somanuals.com. All Manuals Search And Download.
– Notes –
– 61 –
Download from Www.Somanuals.com. All Manuals Search And Download.
– Notes –
– 62 –
Download from Www.Somanuals.com. All Manuals Search And Download.
LIMITATIONS OF THIS SYSTEM
WARNING! THE LIMITATIONS OF THIS ALARM SYSTEM
While this system is an advanced design security system, it does not offer guaranteed protection against burglary or other
emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a variety
of reasons. For example:
•
Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm sensor
or disconnect an alarm warning device.
•
Intrusion detectors (e.g. passive infrared detectors), smoke detectors, and many other sensing devices will not work
without power. Battery operated devices will not work without batteries, with dead batteries, or if the batteries are not
put in properly. Devices powered solely by AC will not work if their AC power supply is cut off for any reason, however
briefly.
•
Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if
the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the
path.
•
•
A user may not be able to reach a panic or emergency button quickly enough.
While smoke detectors have played a key role in reducing residential fire deaths in the United States, they may not
activate or provide early warning for a variety of reasons in as many as 35% of all fires, according to data published by
the Federal Emergency Management Agency. Some of the reasons smoke detectors used in conjunction with this
System may not work are as follows. Smoke detectors may have been improperly installed and positioned. Smoke
detectors may not sense fires that start where smoke cannot reach the detectors, such as in chimneys, in walls, or roofs,
or on the other side of closed doors. Smoke detectors also may not sense a fire on another level of a residence or
building. A second floor detector, for example, may not sense a first floor or basement fire. Moreover, smoke detectors
have sensing limitations. No smoke detector can sense every kind of fire every time. In general, detectors may not
always warn about fires caused by carelessness and safety hazards like smoking in bed, violent explosions, escaping
gas, improper storage of flammable materials, overloaded electrical circuits, children playing with matches, or arson.
Depending upon the nature of the fire and/or the locations of the smoke detectors, the detector, even if it operates as
anticipated, may not provide sufficient warning to allow all occupants to escape in time to prevent injury or death.
•
Passive Infrared Motion Detectors can only detect intrusion within the designed ranges as diagrammed in their
installation manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple
beams of protection, and intrusion can only be detected in unobstructed areas covered by those beams. They cannot
detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors, or
windows.
Mechanical tampering, masking, painting or spraying of any material on the mirrors, windows or any part of the optical
system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature; however, as the
ambient temperature of protected area approaches the temperature range of 90° to 105°F, the detection performance
can decrease.
•
Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers if they are located on the
other side of closed or partly open doors. If warning devices sound on a different level of the residence from the
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may not
hear the warning if the alarm is muffled from a stereo, radio, air conditioner or other appliance, or by passing traffic.
Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep sleepers.
Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service
or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
Even if the system responds to the emergency as intended, however, occupants may have insufficient time to protect
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond
appropriately.
•
•
•
This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed to
last as long as 10 years, the electronic components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance.
This alarm system should be tested weekly to make sure all sensors and transmitters are working properly.
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and
continue to insure their lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their loved
ones to learn about these developments.
– 63 –
Download from Www.Somanuals.com. All Manuals Search And Download.
TWO YEAR LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Communications business (“Seller”), 2 Corporate Center Drive, Melville,
New York 11747 warrants its products to be free from defects in materials and workmanship under normal use and service, normal
wear and tear excepted, for 24 months from the manufacture date code; provided, however, that in the event the Buyer presents a
proper invoice relating to the purchased product and such invoice bears a date later than the manufacture date, then Seller may at
its discretion, reflect the warranty period as commencing at invoice date. Except as required by law, this Limited Warranty is only
made to Buyer and may not be transferred to any third party. During the applicable warranty period, Seller will repair or replace, at
its sole option and as the exclusive remedy hereunder, free of charge, any defective products.
Seller shall have no obligation under this Limited Warranty or otherwise if the product:
(i)
is improperly installed, applied or maintained;
(ii) installed outside of stated operating parameters, altered or improperly serviced or repaired by anyone other than the
Seller/Seller’s Authorized Service/Repair Center;
(iii) damage is caused by outside natural occurrences, such as lightning, power surges, fire, floods, acts of nature, or the like;
or
(iv) defects result from unauthorized modification, misuse, vandalism, alterations of serial numbers, other causes unrelated to
defective materials or workmanship, or failures related to batteries of any type used in connection with the products sold
hereunder.
Exceptions to Warranty With Respect to Honeywell Products listed below:
Hardwire Contacts and PIRs – Seller warrants parts for hardwire contacts and PIRs in accordance with the terms of the above
limited warranty for a period of five (5) years from the manufacture date code.
EXCLUSION OF WARRANTIES, LIMITATION OF LIABILITY
THERE ARE NO WARRANTIES OR CONDITIONS, EXPRESS OR IMPLIED, OF MERCHANTABILITY, OR FITNESS FOR A
PARTICULAR PURPOSE OR OTHERWISE, WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. TO THE
FULL FULLEST EXTENT PERMITTED BY LAW, IN NO CASE SHALL SELLER BE LIABLE TO ANYONE FOR ANY (i)
CONSEQUENTIAL, INCIDENTAL, INDIRECT, SPECIAL, OR PUNITIVE DAMAGES ARISING OUT OF OR RELATING IN ANY
WAY TO THE PRODUCT AND/OR FOR BREACH OF THIS OR ANY OTHER WARRANTY OR CONDITION, EXPRESS OR
IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY
SELLER’S OWN NEGLIGENCE OR FAULT AND EVEN IF SELLER HAS BEEN ADVISED OF THE POSSIBILITY OF SUCH
LOSSES OR DAMAGES. Any product description (whether in writing or made orally by Seller or Seller’s agents), specifications,
samples, models, bulletin, drawings, diagrams, engineering sheets or similar materials used in connection with the Buyer’s order are
for the sole purpose of identifying the Seller’s products and shall not be construed as an express warranty or condition. Any
suggestions by Seller or Seller’s agents regarding use, applications, or suitability of the products shall not be construed as an express
warranty or condition unless confirmed to be such in writing by Seller. Seller does not represent that the products it sells may not be
compromised or circumvented; that the products will prevent any personal injury or property loss by burglary, robbery, fire or
otherwise, or that the products will in all cases provide adequate warning or protection. Buyer understands that a properly installed
and maintained alarm may only reduce the risk of a burglary, robbery or fire without warning, but it is not insurance or a guarantee
that such will not occur or will not cause or lead to personal injury or property loss. CONSEQUENTLY, SELLER SHALL HAVE NO
LIABILITY FOR ANY PERSONAL INJURY, PROPERTY DAMAGE ORF OTHER LOSS BASED ON ANY CLAIM AT ALL
INCLUDING A CLAIM THE PRODUCT FAILED TO GIVE WARNING. However, if Seller is held liable whether directly or
indirectly for any loss or damage with respect to the products it sells, regardless of cause or origin, its maximum liability shall not in
any case exceed the purchase price of the product, which shall be fixed as liquidated damages and not as a penalty, and shall be the
complete and exclusive remedy against the Seller. Should your product become defective during the warranty, please contact your
installer to facilitate repair or replacement with Seller pursuant to the terms hereof. Seller reserves the right to replace any defective
product under warranty with new, refurbished, or remanufactured product.
2 Corporate Center Drive, Suite 100
P.O. Box 9040
Melville, NY 11747
Copyright © 2007 Honeywell International Inc.
ÊK14490V1:Š
K14490V1 7/10 Rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
|