FBII Security System
®
®
OMNI 400/OMNI 600
®
®
OMNI 624/OMNI 848
User Guide
N9939V5 4/04 Rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Reference
TO ARM THE SYSTEM
1. Check to make sure the system is ready. (The Green READY light is lit.)
2. Enter your 4-digit (or 6-digit) user code.
The ARMED/ light will light.
3. Exit through a door designated by your installer as an exit/entry door.
NOTE: If you DO NOT EXIT during the exit time and your system installer has
programmed your system for Auto-Stay, the system will arm in the Auto-Stay
mode.
TO DISARM THE SYSTEM
1. Enter through a door designated by your installer as an exit/entry door.
2. Enter your 4-digit (or 6-digit) user code.
The ARMED/ light will go out.
TO ARM THE SYSTEM AND STAY INSIDE
1. Check to make sure the system is ready. (The Green READY light is lit.)
STAY
2. Press
/
.
3. Enter your 4-digit (or 6-digit) user code.
The ARMED/ light and STAY/
light will both light.
REMEMBER: Unless the Quick Exit feature is enabled, you must disarm the
system if you want to open the door or leave the premises after the exit time has
passed.
TO ARM THE SYSTEM IN INSTANT MODE, AND STAY INSIDE
1. Check to make sure the system is ready. (The Green READY light is lit.)
INSTANT
2. Press
3. Press
/
/
.
.
STAY
4. Enter your 4-digit (or 6-digit) user code.
The ARMED/ light, the INSTANT/
light, and the STAY/
light will all be
lit.
TO RESET SMOKE DETECTOR
1. Enter your 4-digit (or 6-digit) user code twice.
- 3 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Reference (cont)
The following table lists the “Quick Commands” available with this control.
Key
# 1
Description
Quick Arm – if system is ready
Keypads Comments
All keypads Allows you to arm the system without requiring your
user code. User code is always needed to disarm
the system.
Force Arm – bypasses faulted
zones
All keypads Allows you to arm the system even if some zones
are faulted. These zones will be automatically
bypassed and will be unprotected.
# 2
BYPASS
Quick Bypass
All keypads If not enabled, requires user code with authority 1,
2, or 3.
nn (zone no.)
# 3
Set Time and Date
Zone Directory
All keypads May require user code.
LCD* only
Lists each zone with its descriptors. Mode
terminates after last enabled zone.
# 4
Quick Help (OMNI624/848 only)
LCD* only
Provides a listing of all quick commands available in
the system.
# 50
Show Time and Date
Show Auto Arm Time
User Event Log View
Set Auto Arm Time of Current
Partition (OMNI624/848) or
System (OMNI400/600)
LCD* only
LCD* only
LCD* only
May also require code.
May also require code.
Also needs user code with authority level 1 or 2.
# 51
# 52
# 53
# 54
All keypads By partition (OMNI624/848) or system
(OMNI400/600), may also require code.
Display Firmware Version
LCD* only
Displays panel’s revision.
# 55
# 56
Display Key Fob Low Batteries
(OMNI624/848 only)
Door Strike
All keypads Wireless Key Fob battery test.
All keypads Activate doorstrike or trigger. May require certain
user code.
All keypads For keypad partition (OMNI624/848) or system
(OMNI400/600), only LCD* shows phone number.
All keypads LCD* displays current state first, then offers to
toggle. All others just toggle the state.
# 57
# 58
# 6
Change/View Pager Number
Display/Toggle Chime Mode
Assign User to Other Partition
or to Activate Paging
All keypads Need user auth. of 1 or 2. Digit 4 (P) enables user
to page.
# 7
(OMNI624/848 only)
Paging must be enabled and turned on.
User Page Toggle
All keypads Toggles if users should send page for
Open/Close by partition (OMNI624/848) or by
system (OMNI400/600).
# 8
User On-line
All keypads Connects to downloader while on line, disconnects
home phone.
All keypads LCD* displays current enables, 1, 2, 3 – P = 4
NOTE: An entry of 3 is available for the OMNI848
only
# 9
# 0
Multi-Partition (OMNI624/848
only)
* 2-line alpha display
- 4 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Quick Reference (Cont’d)
The following table provides a summary listing of LED indications when using a LED keypad.
SLOW PULSE
(approx. 600mS ON
– 600mS OFF)
FAST BLINK
(approx. 150mS ON
– 150mS OFF)
SLOW BLINK
(approx. 100mS ON
– 900mS OFF)
INDICATOR
ON
Armed
Comm. Fail
Alarm
–
ARM /
AC good
Ready
Syst Batt Trbl
–
–
–
AC/LB /
Program Mode
Alarm memory
READY /
✔
1
2
3
4
5
6
7
8
Zone Fault
Zone Fault
Zone Fault
Zone Fault
Zone Fault
Zone Fault
Zone Fault
Zone Fault
Stay Armed
Zone Trouble
Zone Trouble
Zone Trouble
Zone Trouble
Zone Trouble
Zone Trouble
Zone Trouble
Zone Trouble
–
Zone Alarm
Zone Alarm
Zone Alarm
Zone Alarm
Zone Alarm
Zone Alarm
Zone Alarm
Zone Alarm
–
Zone Bypass
Zone Bypass
Zone Bypass
Zone Bypass
Zone Bypass
Zone Bypass
Zone Bypass
Zone Bypass
–
STAY /
INST /
Instant Armed
Arm disabled
–
–
–
–
–
Phone Fail
TRBL /
–
Bell Supr
Zone Tamper
–
SUPER /
Other LED display combinations:
• Slow Pulse of ARM/ , AC/LB/
, and READY/
LEDs indicate the system is in Walk
✔
Test Mode.
• Fast Blink of Zone and SUPER /
LEDs indicate a tamper condition for the blinking
zone.
- 5 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Introduction
®
Congratulations on your decision to protect your home or business with the OMNI
security system. You have chosen a reliable, state-of-the-art security system that is
remarkably easy to operate. Your system has been professionally installed by your
local Security Company whose representative can explain the specifics of your
system.
The keypad is the input and display device for your security system. Your Security
Company representative will suggest the model most appropriate for your premises
and your needs. There are three types of keypads that can be used with this system:
LCD keypad (alpha display), Fixed-Word keypad (2-digit display), or LED keypad.
Since your system may use any of these keypads, the displays of all keypads are
described in this manual.
The OMNI400, OMNI600, OMNI624, and OMNI848 are listed by Underwriters
Laboratories for Household Fire and Burglary applications.
Throughout this manual, the following conventions are used to represent the
keystrokes required to perform the following functions.
STAY
/
/
/
/
Press Button labeled STAY or
.
BYPASS
Press Button labeled BYPASS or
Press Button labeled INSTANT or
Press Button labeled CODE or
.
INSTANT
CODE
.
.
Enter 4-digit (or 6-digit) user code.
Please keep your manual in a convenient location so you can refer to it if
needed.
- 6 -
Download from Www.Somanuals.com. All Manuals Search And Download.
System Reference
ZONE DESCRIPTIONS
In the following table, enter a description of the area of protection for each zone.
Example: Zone 1 Windows on North side of building.
Zone 4 Main entrance to building.
Zone
1
2
3
4
5
6
7
8
Description
Zone
25*
26*
27*
28*
29*
30*
31*
32*
33*
34*
35*
36*
37*
38*
39*
40*
41*
42*
43*
44*
45*
46*
47*
48*
Description
9*
10*
11*
12*
13*
14*
15*
16*
17*
18*
19*
20*
21*
22*
23*
24*
* Zones 9 through 48 are not used with the OMNI400.
Zones 13 through 48 are not used with the OMNI600.
Zones 25 through 48 are not used with the OMNI624.
Entry time ________ Door __________ Exit time ________
Entry time ________ Door __________
Exit time is the same for all designated entry/exit doors.
- 7 -
Download from Www.Somanuals.com. All Manuals Search And Download.
System Reference (cont)
SEND-HELP ALERT
All keypads are equipped with emergency-pair keys. In order to activate
the alert, both keys must be pressed at the same time. The type of keypad
you have installed dictates which keys you press. Your installer will show you how
to activate these emergency keys. The emergency keys used for all keypads are
shown below.
The following SEND - HELP ALERT is programmed into my system:
KEYS
DESCRIPTION
&
&
&
#
7
1
9
3
NOTE: These key combinations may also be programmed for other system
functions.
PAGER ALERT
If programmed, a button on a designated keyfob may also be used to send an alert
message to a pager. Ask your installer if this was done.
MONITORING STATION INFORMATION
Account #
Telephone #
- 8 -
Download from Www.Somanuals.com. All Manuals Search And Download.
System Reference (cont)
USER CODE ASSIGNMENTS
In the following table, enter the names of the individuals assigned to each user
number.
User
1
2
3
4
5
6
7
8
Assigned To…
User
33*
34*
35*
36*
37*
38*
39*
40*
41*
42*
43*
44*
45*
46*
47*
48*
49*
50*
51*
52*
53*
54*
55*
56*
57*
58*
59*
60*
61*
62*
63*
64*
Assigned To…
9
10
11
12
13
14
15
16*
17*
18*
19*
20*
21*
22*
23*
24*
25*
26*
27*
28*
29*
30*
31*
32*
* User Codes 16 through 64 are not used with the OMNI400 or OMNI600.
User Codes 33 through 64 are not used with the OMNI624.
____ ____
4-digit 6-digit
USER CODE NOTE: User codes can be either 4 digits or 6 digits, depending on installer
programming. Ask your installer what type of user codes (4 or 6 digits) are being used in
your system. When performing system functions, you must use the appropriate 4- or 6-
digit user codes.
- 9 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Arming the System
IS THE SYSTEM READY?
You can arm and disarm the burglar portion of your security system. Before you
can arm the system, it must be “ready.” If you have a protected door open, or
someone is moving in view of a motion detector, the system will not display the
“READY” message.
The system is ready if the READY/
light is lit and the display shows:
✔
LCD Keypad:
Fixed-Word Keypad:
READY/ LED lit
LED Keypad:
READY/ LED lit
SYSTEM READY
✔
✔
NOTE: If programmed by your installer, you may arm the system if a delay or
interior zone is faulted. However, faulted zones must be restored before your exit
time expires or an alarm or zone bypass will result. Ask your installer if your
system has this feature and, if so, if it causes an alarm or zone bypass.
TO ARM THE SYSTEM AND LEAVE
Enter your user code.
The System ARMED/ light will go on and the display will show:
LCD Keypad:
ON: AWAY
Fixed-Word Keypad:
ARM/ LED lit
120
LED Keypad:
120s
ARM/ LED lit
NOTE: The number 120 shown above for the LCD and Fixed-Word keypads
indicates a counter that is updated every second and displays the amount of time
remaining to exit without sounding an alarm.
Exit through a door designated by your installer as an exit/entry door. You must
leave within the exit time programmed by your installer. Refer to the reference
sheet for the time that has been set for your system.
This system can be programmed by the installer for the AUTOSTAY feature, which
automatically bypasses interior zones programmed for AUTOSTAY if you arm the
system and do not exit through a delay zone during exit time.
- 10 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Arming the System (cont)
WHEN THE SYSTEM IS NOT READY
If the system is not ready to be armed, the READY/
light will be off and the
✔
display will show which zone or zones are not ready. The following conditions will
be indicated by the zone lights (LED keypad) or described on the display:
Fast Blink ...............................Alarm or tamper condition
Slow Blink/Low Intensity ...Bypass
Slow Pulse ..............................Trouble, problem with RF receiver, or low battery
Solid On ...................................Zone faulted
Example: If the READY/
light is not lit and the Zone 1 light is solid on, an
✔
alarm sensor on Zone 1 is faulted. This might mean that a door is open or someone
is walking in view of a motion sensor. Check all sensors on Zone 1 and resolve the
problem. When all sensors are restored, the READY/
light will come on and the
✔
zone light will go out. In this example, the display shows:
NOT READY
NOT RDY
FRONT DOOR
ZN 1
and
Determine which zone or zones are not ready, resolve the problem, and arm the
system normally. If the problem cannot be resolved, you may bypass the zone that
is not ready. Bypassing should only be done if the problem on the zone cannot be
resolved, OR if you intentionally wish to leave the zone disarmed. For example, you
would leave the zone disarmed if you plan to keep the window open for ventilation.
Zones that are bypassed are not protected when the system is armed. See
TO BYPASS A ZONE on page 13 for a description of the procedure.
TO ARM THE SYSTEM AND STAY INSIDE
To arm the perimeter portion of your burglar alarm and move around freely inside
the premises, use the STAY mode.
Check to make sure the system is ready. When it is ready, press:
STAY
/
followed by your user code.
When the system has been armed successfully, the ARMED/ (STAY) light is lit
and the following is displayed:
LCD Keypad:
Fixed-Word Keypad:
LED Keypad:
ON: STAY
STAY/
ARM/ and STAY/
LEDs lit
STAY
REMEMBER: You must disarm the system or press
/
to initiate
the “quick exit” if you want to open the door or leave the premises after the exit
time has expired. Quick Exit restarts the exit time without disarming the system.
- 11 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Arming the System (cont)
TO ARM THE SYSTEM IN INSTANT MODE
In INSTANT mode, all alarm sensors, including doors that normally have a delay
to allow you to disarm the system, will report an alarm immediately if activated.
Check to make sure the system is READY/
. When it is ready, press:
✔
INSTANT
/
followed by your user code.
When the system has been armed successfully, the ARM/
light and the
INSTANT/
light are lit, and the following is displayed:
LCD Keypad:
ON: INSTANT
Fixed-Word Keypad:
INSTANT/
LED Keypad:
ARM/ and INSTANT/
LED lit
TO ARM THE SYSTEM IN INSTANT MODE AND STAY INSIDE
In INSTANT STAY mode, the perimeter portion of your burglar alarm system is
armed, but the time delays are eliminated from your normal entry/exit door(s). All
interior protection is disarmed, so you are free to move around inside.
Check to make sure the system is READY/
. When it is ready, press:
✔
INSTANT
/
STAY
/
followed by your user code.
When the system has been armed successfully, the ARM/
light, the INSTANT /
light, and the STAY/
light are all lit, and the following is displayed:
LCD Keypad:
ON: STAY / INS
Fixed-Word Keypad:
LED Keypad:
ARM/ , STAY/ , and
INSTANT/ LEDs lit
STAY/
INSTANT/
- 12 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Arming the System (cont)
TO BYPASS A ZONE
The Bypass function excludes a zone of protection from the security system until it
is unbypassed (either by using the unbypass procedure or when you disarm the
system). Bypassing can only be done while the system is disarmed.
NOTE: 24-hour zones may be bypassed, but can only be unbypassed if the zone is
not faulted (condition has been cleared).
Press the BYPASS/
button. Then enter your user code and the zone number
to be bypassed, as follows:
+ Zone
No.
followed by your user
code†
BYPASS
/
† If the Quick Bypass feature has been enabled by the installer, do not enter the
user code when bypassing zones.
NOTE: Bypassed zones are NOT protected when the system is armed. After the
bypass command has been accepted, the keypad sounds one long beep, and the
following is displayed:
LCD Keypad:
BYPASSED: ZN 01
FRONT DOOR
Fixed-Word Keypad:
BYPASS/
Zone number displayed
LED Keypad:
Zone LEDs of the zone(s)
bypassed slowly blink
To Bypass multiple zones, within 10 seconds of the BYPASS/
Zone No. entry, enter:
+ User Code +
BYPASS
/
+
Zone No.
This command can be repeated for each zone to be bypassed.
TO UNBYPASS A ZONE
Pressing the BYPASS/
button returns a bypassed zone to normal operation.
To unbypass a zone, the system must be disarmed. (Also note that 24-hour zones
cannot be unbypassed if they are faulted.) To unbypass a zone(s), repeat the bypass
function as follows:
+ Zone
No.
followed by your user
code†
BYPASS
/
† If the Quick Bypass feature has been enabled by the installer, do not enter the
user code when unbypassing zones.
After unbypassing, the zone display will show the state of the zones.
- 13 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Disarming the System
When you disarm the system, you disarm only the burglar portion of your system;
any smoke or heat detectors and panic keys will remain armed. You must enter
through a designated entry door and disarm the system within the time allowed.
You can have different amounts of time for different entry points. See your system
reference sheet (page 7) for the times established for your system.
To disarm your system:
Enter your user code.
If no alarms have taken place, the ARMED/
light will go off, or the display
shows:
LCD Keypad:
SYSTEM READY
Fixed-Glass Keypad:
READY/ LED lit
LED Keypad:
READY/
LED lit
✔
✔
If alarms occurred when the system was armed or if a trouble condition exists, the
display shows:
LCD Keypad:
ALM MEM
Fixed-Glass Keypad:
LED Keypad, zone LEDs:
Fast Blink = alarm or tamper
Slow Blink = bypass
ZN1
ARM LED/ lit
Slow Pulse = trouble, problem
with RF receiver, or low battery
Solid On = zone faulted
READY/
LED blinks
✔
Burglary alarms will sound a steady tone at the keypad(s), and fire alarms will
generate a pulsing sound.
IMPORTANT: If an intrusion has taken place while you were away, do not enter
until the location has been checked. Call for help from a neighbor's house and wait
there for the police.
To clear the display of alarm or trouble conditions and silence the audible alert:
Enter your user code again.
- 14 -
Download from Www.Somanuals.com. All Manuals Search And Download.
User Codes
TO ADD OR CHANGE A USER CODE
Users can be added or changed directly at the keypad. Your system can have up to
15 (OMNI400 and OMNI600), 32 (OMNI624), or 64 (OMNI848) different user codes,
with each assigned to one of four authority levels and to a primary partition
(OMNI624 and OMNI848 only). The authority level determines the functions that
user can perform. In addition, your system can be set up for 4-digit or 6-digit user
codes. Ask your installer which type of user codes is used in your system.
To add or change a user code, press the following:
CODE
/
+
Master User Code
User ID*
New User Code
Auth. Level
nn
[1-4]
* Valid User ID numbers are 01–15 for the OMNI400 and OMNI600, 01–32 for the
OMNI624, or 01–64 for the OMNI848.
Authority Levels
Level Functions Allowed
1
Primary Master: access all partitions; can view log and set time; assign other user
codes; all system functions
2
Secondary Master: same as primary master except cannot change the primary
master’s code
3
4
User: cannot assign codes and cannot bypass zones
Limited user: same as level 3, except can disarm the system only if it was armed by
another user with level 4 authority (cannot disarm if armed by user of higher authority
level).
ASSIGNING PARTITIONS TO USERS (OMNI624 and OMNI848 ONLY)
When a user code is assigned, that user is automatically allowed to perform system
functions in the partition in which the user’s code is assigned. You can also allow
users to access other partitions and turn on open/close reporting to a pager by using
the #7 command as follows:
[master user code] [user no.] [1, 2, 3*, or 4]
#
7
where: master user code = user with authority level 1 or 2
user no. = the user that will be assigned access to other partitions
1, 2, 3, or 4 = enter the partition(s) 1-3* you want this user to have access
to; enter 4 if you want this user to send open/close reports to a pager
* Partition 3 is available on the OMNI848 ONLY.
- 15 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Miscellaneous Commands
TO DELETE A USER CODE
To delete a user, press the CODE/
button followed by the 4-digit (or 6-digit)
master user code. Enter the user number, then press [#] to delete. For example, to
delete user 3, do the following:
Master User Code
User ID
# to delete
CODE
/
03
[#]
NOTE: User no. 1, the master user, cannot be deleted but it can be changed using
the ADD OR CHANGE A USER CODE procedure.
DURESS
Your system can be programmed to send an emergency signal to the central station
if you are forced to enter the premises under threat. If you choose to include this
feature, assign codes to user 15 (OMNI400 and OMNI600), 31 and 32 (OMNI624),
or 60-64 (OMNI848), which are dedicated to this function, if programmed. Use
these codes only under a duress circumstance.
QUICK ARMING
If programmed by your installer, Quick Arming allows you to arm the system in the
AWAY mode without entering a user code.
Press
, then
.
#
1
NOTES:
• Disarming your system always requires a valid user code.
• This system can be programmed by the installer for the AUTOSTAY feature
which automatically bypasses interior zones if you arm the system and do not
exit through a delay zone during exit time.
QUICK FORCED ARMING
If programmed by your installer, Quick Forced Arming allows you to arm the
system in the AWAY mode by automatically bypassing all zones that are not ready.
Press
, then
.
#
2
NOTES:
• A valid user code is still required to disarm the system.
• This system can be programmed by the installer for the AUTOSTAY feature
which automatically bypasses interior zones programmed for AUTOSTAY if you
arm the system and do not exit through a delay zone during exit time.
UL NOTE: This feature is disabled on UL installations.
- 16 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Miscellaneous Commands (cont)
QUICK BYPASS
If you have Quick Bypass programmed for your system, you can bypass zones
without entering your user code. The Quick Bypass procedure is:
BYPASS
/
2-digit Zone No. (e.g., 01 for zone 1)
NOTE: Bypassed zones are not protected when the system is armed. After the
bypass command has been accepted, the keypad sounds one long beep. The zone
light of the bypassed zone(s) slowly blinks, or the display shows:
LCD Keypad:
BYPASSED: ZN1
Fixed-Word Keypad:
BYPASS/ LED lit
LED Keypad:
Zone light of the bypassed
zone(s) will slowly blink
NOTE: Temporary users (e.g., babysitters, housekeepers, etc.) should not be shown
the Bypass procedure.
QUICK EXIT
Quick Exit restarts the exit delay time if the system is already armed. This allows
someone to leave after the system has been armed, without having to disarm the
system first.
STAY
To restart the exit delay time, press:
/
TURN CHIME ON/OFF
Chime is an optional feature that causes the keypad to beep when selected doors
are opened while the burglary protection is off or disarmed.
Only your installer can program a zone for the Chime feature, but once
programmed, you can turn Chime on or off to meet your daily needs.
To turn Chime on or off: Press
, then
.
#
6
ASSIGN USERS ACCESS TO OTHER PARTITIONS (OMNI624 and OMNI848 ONLY)
You can assign users access to any of the partitions in a multi-partition system by
entering the following:
[master code] [user number] [1, 2, 3*]
#
7
where 1, 2, 3* are the partitions to which the user is authorized to access.
* Partition 3 is available on the OMNI848 ONLY.
- 17 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Miscellaneous Commands (cont)
CHANGE PARTITION (OMNI624 and OMNI848 ONLY)
To arm or disarm other partitions from your keypad, enter the following:
[1-3, 0, 9]
where: 1-3* = the desired partition you wish to change to
When you enter a partition number (1-3*), the system displays the
#
0
current armed state for that partition. You can then arm or disarm
the partition by entering the arming/disarming command.
= arms all partitions
0
9
= disarms all partitions
* Partition 3 is available on the OMNI848 ONLY.
SET AUTO-ARM TIME
Set Auto-Arm Time lets you set the time your system will automatically arm.
To set the Auto On Time:
Press
+
+
+ user code + hour 00-23 + minute 00-59.
#
5
4
The keypad will prompt you for the required entries.
TO VIEW AUTOARM TIME
To view the autoarm time for the partition to which the keypad is assigned, press:
+
+
+ user code with authority level 1 or 2.
#
5
2
AUTOARM TIME:
05:00PM
(The user code is not required if so programmed by installer.)
DOOR STRIKE
To activate door strikes:
Press
+
+
+ Door No.
#
5
7
If programmed, certain user codes can also be used to open a door. See your installer
for door numbers.
- 18 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Miscellaneous Commands (cont)
VIEW QUICK COMMAND LIST (LCD Keypads on OMNI624 and OMNI848 ONLY)
To view a display of available quick commands, press:
+
+
.
#
5
0
To step through the available quick commands, press
.
#
To exit the quick command list, press
.
VIEW TIME (LCD KEYPADS ONLY)
To view the system time, press:
as follows:
+
+
. A typical display is
#
5
1
Jan 27, 2001
08:15A
SET TIME
To set the time, press:
+
+ user code (not required if so
#
3
programmed by installer), then follow the prompts (on LCD keypads only) and enter
the hour, minute, month, day, and year. All entries are 2-digit entries. Additionally, if
your system installer has set your system to use an internal crystal real-time clock,
you will be promted to enter a crystal adjustment. If your clock has been keeping the
proper time, respond to the crystal adjustment prompt by pressing
followed
1
by when the system prompts you for an adjustment value. If the
0
0
clock has not been keeping time correctly, when the crystal adjustment prompt is
displayed, proceed as follows:
1. Enter 0 (Adjust down - Clock fast) or 1 (Adjust up - Clock slow). The adjustment
value prompt is displayed.
2. Determine how far off the clock is (in seconds) from the correct time.
3. Determine the number of days since the last time the clock was set.
4. Divide the number of seconds that the clock is off by the number of days since
the last time the clock was set.
5. Enter the result of step 4 as the adjust value. Valid entries are 00 for no change,
1–29 for seconds to add (per day), or 1–30 for seconds to subtract (per day). If the
value entered is valid, an acknowledgement is sounded. If the value entered is
not within the valid range, an error is sounded.
- 19 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Miscellaneous Commands (cont)
DISPLAY ZONE DIRECTORY (LCD KEYPADS ONLY)
To view a list of the zones in the current partition, press
zones will automatically scroll.
+
. The
#
4
USER LOG VIEW (LCD KEYPADS ONLY)
To view the system log, press:
+
, +
+ user code.*
#
5
3
(*The user code is not required if so programmed by installer.)
When the command is accepted, the display will show the most recent event.
STAY
Pressing either
/
or
exits this mode.
Pressing any other key advances to the next valid log entry.
KEY FOB LOW-BATTERY TEST (OMNI624 and OMNI848 ONLY)
To activate the key fob low-battery test:
Press :
then
+
#
5
6
The test mode is indicated as follows:
LCD Keypad:
Keyfob Bat. Test
#56
Fixed-Word Keypad:
LED Keypad:
An acknowledgement tone is
sounded.
AC
✱=Exit
FO
TEST
When a keyfob button is pressed, the system will provide a display indicating if the
keyfob has a low-battery condition.
The system exits this mode when the star
key is pressed.
KEYPAD BACKLIGHT TIMER
If you are using an OMNI-KP, OMNI-KP-US, OMNI-LCD, or OMNI-LCD-US
keypad, these keypads have a timer controlled keypad backlight that is on for 120-
seconds following a key press (timer on) or constantly on (timer off).
To change the backlight timer:
CODE
INSTANT
OMNI-KP or OMNI-KP-US: Press the
at the same time and hold down for two seconds until you hear a beep. Pressing the
key toggles a zero or one in the display.
/
and
/
keys
1
0 = Timer off (backlight always on)
1 = Timer on (backlight on for 120-seconds following key press)
Press the
key to exit this Backlight menu.
- 20 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Miscellaneous Commands (cont)
INSTANT
OMNI-LCD or OMNI-LCD-US: Press and hold down the
/
and
CODE
/
keys at the same time for about two seconds. Press the
1
key to toggle the display between:
Backlight 120s time out …. and …. Backlight Always On
Press the [✱] key to exit this Backlight menu.
KEYPAD SOUNDER
The sounder (or loudspeaker) housed inside the keypad emits (annunciates) sounds
according to the condition of the security system. If you are using an OMNI-KP,
OMNI-KP-US, OMNI-LCD, or OMNI-LCD-US keypad, the sounds from the keypad
sounder can be controlled.
To change the keypad sounder:
BYPASS
CODE
OMNI-KP or OMNI-KP-US: Press the
/
and
/
keys
at the same time and hold down for two seconds until you hear a beep. Press any
key (except the
0 = Sounder off
key) to toggle the sounder on or off.
1 = Sounder on
Press the [✱] key to exit the sounder menu.
OMNI-LCD or OMNI-LCD-US: There are four modes available in the Sounder Menu.
They are as follows:
• On – Normal Sounder Keys (all sounds on)
• Key – Only Key Clicks
• Fire – Only Fire Sounder (temporal sounder – not supported by all systems)
• Off – No Sounds at all
To use the OMNI-LCD or OMNI-LCD-US sounder menu:
BYPASS
CODE
1. Press the
/
and
/
keys at the same time and
hold down for two seconds. This accesses the Sounder Menu.
2. Press the
desired mode).
3. Press the
appears on the display).
4. Press the key to adjust the sound of the key acknowledge (Ack H or L
appears on the display).
5. Press the key to exit the Sounder Menu.
key to toggle through the four modes listed above (stop at
1
key to toggle through the sounder volume choices (high or low
2
3
- 21 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Using a Pager
If so programmed, the system can send messages to a pager. The messages are
displayed as follows:
ACCT E XXX
where:
"ACCT" = the 4-digit central station No. 1 account number set by your system
installer. We suggest that you obtain the number from your system
installer and record it here. "ACCT" =
"E" = the event code. There are 4 event types: alarms, troubles, openings, and
closings. These event codes are as follows:
Openings = 0, Closings = 1, Alarm or Trouble = 9
"XXX" = the zone* or user* designation, depending on the event.
* Possible Zone numbers are: 001–008 (OMNI400), 001–012 (OMNI600),
001–024 (OMNI624), 001–048 (OMNI848)
Possible User numbers are: 001–015 (OMNI400 and OMNI600), 001–032
(OMNI624), 001–064 (OMNI848)
Note that the following actions not requiring a user code are reported as:
• Soft keys *&#, 1&3, and 7&9 send event number 9 and zone number of 124.
• If the system is programmed by your installer for Stay Arms Stay, when the
system is armed by pressing the [STAY/ ] key it will be reported to the pager as
user 001.
• If the system is programmed by your installer for Instant Arms Away, when the
system is armed by pressing the [INSTANT/
] key it will be reported to the
pager as user 001.
• If the system is armed with a keyswitch, programmable digits that were set up by
your installer will be sent to the pager as the user number.
• When the system auto arms, it will be reported to the pager as user number 126.
If multiple events occur, only the signal for the highest-priority event is sent. Events ranked from
highest to lowest priority are alarm, trouble, open, and close.
CHANGING THE PAGER PHONE NUMBER (FOLLOW-ME)
You can change your pager follow-me phone number as follows if your installer
enabled this feature:
1. Access pager number programming by pressing the following keys in sequence:
,
, and
.
#
5
8
An acknowledgement tone sounds to indicate pager number programming has
been accessed.
- 22 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Using a Pager (cont)
The [#], [5], [8] command is accessible only while the system is disarmed and the dialer, dialer
delay, and bell are not active.
In pager phone number programming mode, only the LCD keypad provides visual display of the
numbers already programmed or numbers that are being changed. The LED and fixed-word
style keypads provide no visual keypad display of these numbers.
2. Enter your new pager phone number. Your new pager phone number may
consist of up to 16 characters (1-9, 0). It may be necessary to add time to allow
the pager to answer before dialing your pager number. To enter a 2-second
CODE
pause, press the
/
key. (Entering a 2-second pause is optional
and is not required to enter your pager phone number.) If the CODE/
was pressed, it counts as one character. The keypad will emit a single
acknowledgement chirp as each number is pressed.
key
3. Press the
key after you have made your pager phone number changes.
#
Pressing the [#] key saves your new pager number and nulls out the remaining
locations. An acknowledgement tone sounds.
To exit without saving changes, press the
key to exit pager phone number
programming. An acknowledgement tone sounds to indicate pager number
programming has been exited.
If you press the [✴] key without first pressing the [#] key to save your new pager phone number,
the system exits the pager phone number programming mode without saving the changes.
If no key is pressed within 10 seconds, the pager phone number programming mode times out
and exits automatically without saving any information entered.
TURN PAGER REPORTING ON/OFF FOR THE PARTITION (OMNI624 and 848 ONLY)
You can turn on/off the open-close reporting feature for a partition by pressing
,
. The display prompts you to toggle the feature on/off with the
#
#
8
key. To exit, press the key.
TURN PAGER REPORTING ON/OFF FOR A USER
You can turn on/off the open-close reporting feature for a user by entering the
following :
,
, [master code] [user number] [4]
#
7
NOTE: The [#], [7] command is also used to assign a user to a different partition for
the OMNI624 and 848 only (see ASSIGNING PARTITIONS TO USERS on page 15).
- 23 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Testing the System
SYSTEM TEST
It is recommended that you test your system once a week using the
following procedure:
NOTE: If your system is monitored, contact your central station before you perform
this test.
1. Arm your security system.
2. Wait until your exit time is over. Then activate the system by opening a protected
zone (for example: a window or door).
3. Confirm that the alarm sounding device (bell or siren) sounds. If your system is
connected to a central station, the keypad will sound the ringback tone to confirm
that the signal was received.
4. Disarm the security system.
5. Call the central station to tell them you are finished testing.
BATTERY TEST
It is recommended that you test your battery once a month. In order to test your
backup/standby battery, the following procedure should be followed:
1. Disconnect AC Power from the system.
2. Observe that the AC indicator light on the keypad goes off.
3. Activate your alarm by performing the above SYSTEM TEST. Remember to
contact your central station if your system is monitored.
4. Reconnect AC Power to the system.
IMPORTANT: Use only batteries recommended by your installer as a replacement.
The National Fire Protection Association publishes a standard for fire warning
equipment (NFPA publication #72). Further information can be obtained by
contacting: NFPA Public Affairs Dept., Batterymarch Park, Quincy, MA 02269.
If you have any further questions about the operation of your system, please contact
your alarm company.
- 24 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Recommendations On Smoke Detectors
With regard to the number and placement of smoke/heat detectors, we subscribe to
the recommendations contained in the National Fire Protection Association’s (NFPA)
Standard #72 noted below.
Early warning fire detection is best achieved by the installation of fire detection
equipment in all rooms and areas of the household as follows: A smoke detector
installed outside of each separate sleeping area, in the immediate vicinity of the
bedrooms and on each additional story of the family living unit, including basements
and excluding crawl spaces and unfinished attics.
In addition, the NFPA recommends that you install heat or smoke detectors in the
living room, dining room, bedroom(s), kitchen, hallway(s), attic, furnace room, utility
and storage rooms, basements, and attached garages.
KITCHEN
KITCHEN
LIVING ROOM
BDRM
BDRM
DINING
BEDROOM
BEDROOM
TV ROOM
DINING
BEDROOM
BEDROOM
LIVING ROOM
Smoke Detectors for Minimum Protection
Smoke Detectors for Additional Protection
Heat-Activated Detectors
BEDROOM
TO
BR
BEDROOM
BEDROOM
KTCHN
GARAGE
CLOSED
DOOR
LVNG RM
.
BASEMENT
floor_plan-V0
- 25 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Emergency Evacuation
Establish and regularly practice a plan of escape in the
event of fire. The following steps are recommended by the
National Fire Protection Association:
1. Position your detector or your interior and/or exterior
sounders so that they can be heard by all occupants.
OOM
BEDR
CLOSET
2. Determine two means of escape from each room. One
path of escape should lead to the door that permits
normal exit from the building. The other is an
alternative route, such as through a window, should your
normal escape path be unpassable. Station an escape
ladder at such windows if there is a long drop to the
ground.
H
T
OOM
BEDR
OOM
BEDR
BA
2nd FLOOR
OOM
BEDR
KITCHEN
BACK DOOR
3. Sketch a floor plan of the building. Show windows,
doors, stairs, and rooftops that can be used to escape.
Indicate escape routes for each room. Keep these routes
free from obstruction and post copies of the escape routes
in every room.
H
OOM
BEDR
T
BA
1st FLOOR
4. Assure that all bedroom doors are shut while you are
asleep. This will prevent deadly smoke from entering
while you escape.
5. Try the door. If the door is hot, check your alternate
escape route. If the door is cool, open it cautiously. Be
prepared to slam the door shut if smoke or heat rushes
in.
BACK
6. When smoke is present, crawl on the ground. Do not
walk upright, since smoke rises and may overcome you.
Clearer air is near the floor.
7. Escape quickly; don’t panic.
FRONT
8. Establish a common meeting place outdoors, away from
your house, where everyone can meet and then take
steps to contact the authorities and account for those
missing. Choose someone to assure that nobody returns
to the house — many die going back.
floor_plan2-V0
- 26 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary
AC/
:
Small green power on-off light between the center buttons on the keypad. When lit, the
system is running on primary power; when not lit, the system is running off the backup battery.
ALARM: Sound from keypad or other horn/siren indicates a burglar alarm, fire alarm, or other
condition you should be alerted to.
ARMED/DISARMED: These terms refer to the burglary portion of your security system. There are
several levels of operation that allow you to protect part of your premises while you remain inside.
Fire sensors and other emergency and environmental features are always active and ready (armed);
they are not affected in any way by arming or disarming the burglary portion of your security
system. See ARMED-INSTANT, ARMED-STAY, and STAY.
ARM-STAY:
A system setting that turns on the perimeter protection of the building but allows
movement throughout the interior.
ARMED INDICATOR: Red light in the upper portion of the keypad labeled "Armed/ ." When lit, some
part of the burglar alarm system is armed; when not lit, the burglary portion of the system is
disarmed.
AWAY: A system setting that protects the premises while it is unoccupied. All burglary sensors are
active.
BURGLARY/FIRE: The two major functions of a security system. Fire protection is always armed and
cannot be disarmed. The burglary sensors protect against unauthorized entry into your premises.
The burglary protection can be armed and disarmed, and programmed for special levels of access
and notification.
BYPASS FEATURE: The Bypass feature allows you to exclude a selected zone or zones from the
burglar alarm protection.
BYPASS/
BUTTON: A button on the keypad used to activate the Bypass feature.
CENTRAL STATION: The signal monitoring center contacted by your security system over the
telephone and/or other communication channels when alarms are activated, if your system is
programmed to communicate alarms off site. The central station will follow their procedures and
your instructions for contacting the proper authorities when a signal is received.
CHIME FEATURE: An optional feature that causes the keypad to chime for one second when selected
doors are opened when the burglary protection is disarmed. Once programmed by your installer,
you can turn Chime on and off with [#] [6].
DISARMED: See ARMED/DISARMED.
DURESS: Duress is a system feature that you may have programmed into your system. If someone
forces you to disarm your system, entering the special Duress user code disarms the system and
sends a silent duress emergency signal to the central station so personnel there can respond
appropriately.
ENTRY DELAY: The period of time allowed between opening a designated entry/exit door and
disarming the alarm system before the system registers an alarm condition. This is determined at
the time of installation. Your system supports two entry times, allowing you to have a different
length of time for different doors.
- 27 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Glossary (cont)
EXIT DELAY: The period of time allowed between arming the system and leaving through a designated
exit/entry door before the system will register an alarm condition. This is determined at the time of
installation.
INTERIOR ZONE: An interior zone is a group of points that protect the interior of your premises. You
may want to arm the perimeter portion of your system while leaving the interior zones disarmed to
allow you to open interior doors and pass interior motion detectors without causing an alarm.
KEYPAD: A keypad is your link into your system. It displays alarm and trouble messages, shows
faulted zones, and allows you to arm/disarm the system using the buttons. Your system will have
one or more keypads.
PANIC BUTTON: A push button that allows you to signal the central station that you need immediate
assistance. Your system has programmable Keypad Send Help Alerts that can also serve as Panic
buttons.
PERIMETER ZONE: A perimeter zone is a group of points that protect the exterior of your premises.
Your outside doors and windows would be programmed as a perimeter zone.
SENSOR: The actual alarm sensor, detector or device installed to detect an intrusion, fire, or
environmental problem. Examples include: door contacts, window contacts, motion sensors,
glassbreak sensors, smoke detectors, rate-of-rise heat detectors, temperature sensors, flood/water
sensors, and carbon monoxide gas detectors.
SILENT CONDITION: Most types of alarms and troubles alert you with the keypad sounder and the
sirens, horns, or speakers located in your premises. The intent is to advise you of the alarm or
trouble and allow you to respond promptly. The audible sounds also let an intruder know that he
has been detected and will hopefully scare him away. In some circumstances, an audible alarm
might put your life in danger. For that reason, those alarms are programmed as silent conditions.
For an example, see DURESS.
SYSTEM: Your security system is composed of three main parts: 1) the control panel, which functions
as the system brain and the link to the monitoring agency (central station); 2) the keypad(s), which
provide you with system status and allow you to input commands; 3) security sensors such as door
and window contacts, motion sensors, smoke detectors, and other sensors as required to detect
intrusion, fire, and other conditions for your premises.
USER CODE: A user code is a 4- or 6-digit code that is required to operate the system. The OMNI400
and OMNI600 supports up to 15 separate user codes, the OMNI624 supports up to 32 separate user
codes, and the OMNI848 supports up to 64 separate user codes. The system supports one master
user who can add/delete other user codes. Two of the user codes may be dedicated to special
functions as defined by your alarm company at the time of installation. (See the User Code
Assignments in this manual.)
ZONE: A zone is a collection of sensors with common characteristics grouped together for your
operating convenience.
- 28 -
Download from Www.Somanuals.com. All Manuals Search And Download.
RADIO FREQUENCY EMISSIONS STATEMENTS
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 15
This device complies with part 15 of the FCC rules. Operation is subject to the following two conditions: (1) This
device may not cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation.
INDUSTRY CANADA
This Class B digital apparatus complies with Canadian ICES-003.
Cet Appareil numérique de la classe B est conforme à la norme NMB-003 du Canada.
TELEPHONE/MODEM INTERFACE STATEMENTS
FEDERAL COMMUNICATIONS COMMISSION (FCC) Part 68
This equipment complies with Part 68 of the FCC rules. On the front cover of this equipment is a label that contains
the FCC registration number and Ringer Equivalence Number (REN). You must provide this information to the
telephone company when requested.
This equipment uses the following USOC jack: RJ31X
This equipment may not be used on telephone-company-provided coin service. Connection to party lines is subject
to state tariffs. This equipment is hearing-aid compatible.
INDUSTRY CANADA
NOTICE: The Industry Canada Label identifies certified equipment. This certification means that the equipment
meets telecommunications network protective, operational and safety requirements as prescribed in the appropriate
Terminal Equipment Technical Requirements document(s). The Department does not guarantee the equipment will
operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be installed using an acceptable method of connection. The
customer should be aware that compliance with the above conditions may not prevent degradation of service in
some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or
alterations made by the user to this equipment, or equipment malfunctions, may give the telecommunications
company to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility, telephone
lines and internal metallic water pipe system, if present, are connected together, This precaution may be particularly
important in rural areas.
Caution: Users should not attempt to make such connections themselves but should contact appropriate electric
inspection authority, or electrician, as appropriate.
RINGER EQUIVALENCE NUMBER NOTICE
The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the maximum
number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist
of any combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all
the devices does not exceed 5.
- 29 -
Download from Www.Somanuals.com. All Manuals Search And Download.
INDUSTRIE CANADA
AVIS: L’étiquette d’Industrie Canada identifie le matériel homologué. Cette étiquette certifie que le matériel est
conforme aux normes de protection, d’exploitation et de sécurité des réseaux de télécommunications, comme le
prescrivent les documents concernant les exigences techniques relatives au matériel terminal. Le Ministère n’assure
toutefois pas que le matériel fonctionnera à la satisfaction de l’utilisateur.
Avant d’installer ce matériel, l’utilisateur doit s’assurer qu’il est permis de le raccorder aux installations de l’enterprise
locale de télécommunication. Le matériel doit également être installé en suivant une méthode acceptée da
raccordement. L’abonné ne doit pas oublier qu’il est possible que la conformité aux conditions énoncées ci-dessus
n’empêche pas la dégradation du service dans certaines situations.
Les réparations de matériel nomologué doivent être coordonnées par un représentant désigné par le fournisseur.
L’entreprise de télécommunications peut demander à l’utilisateur da débrancher un appareil à la suite de réparations
ou de modifications effectuées par l’utilisateur ou à cause de mauvais fonctionnement.
Pour sa propre protection, l’utilisateur doit s’assurer que tous les fils de mise à la terre de la source d’energie
électrique, de lignes téléphoniques et des canalisations d’eau métalliques, s’il y en a, sont raccordés ensemble.
Cette précaution est particulièrement importante dans les régions rurales.
Avertissement: L’utilisateur ne doit pas tenter de faire ces raccordements lui-même; il doit avoir racours à un
service d’inspection des installations électriques, ou à un électricien, selon le cas.
AVIS: L’indice d’équivalence de la sonnerie (IES) assigné à chaque dispositif terminal indique le nombre maximal
de terminaux qui peuvent être raccordés à une interface. La terminaison d’une interface téléphonique peut consister
en une combinaison de quelques dispositifs, à la seule condition que la somme d’indices d’équivalence de la
sonnerie de tous les dispositifs n’excède pas 5.
TELEPHONE OPERATIONAL PROBLEMS
In the event of telephone operational problems, disconnect the control by removing the plug from the RJ31X wall
jack. We recommend that your certified installer demonstrate disconnecting the phones on installation of the system.
Do not disconnect the phone connection inside the control/communicator. Doing so will result in the loss of your
phone lines. If the regular phone works correctly after the control/communicator has been disconnected from the
phone lines, the control/communicator has a problem and should be returned for repair. If upon disconnection of the
control/communicator, there is still a problem on the line, notify the telephone company that it has a problem and
request prompt repair service. The user may not under any circumstances (in or out of warranty) attempt any service
or repairs to the system. It must be returned to the factory or an authorized service agency for all repairs.
This control unit was manufactured under rigid quality standards and complies with all UL requirements for
its intended use. Maintenance is best performed by your installing company with trained service personnel.
0560 DECLARATION OF CONFORMITY
Application of Council Directives 98/482/EC, 89/336/EEC, 73/23/EEC
Standards to which conformity is declared:
ETS 300 001:1997
EN50081-1
EN 50130-4:1995
EN 60950:1998
Intended use:
Restrictions:
Alarm system, analogue subscriber interface to PSTN
None
EMC environment: RESIDENTIAL, COMMERCIAL AND LIGHT INDUSTRY
Manufacturer:
Address:
Honeywell International Inc.
165 Eileen Way, Syosset NY 11791, USA
Customer support: Contact your local distributor
- 30 -
Download from Www.Somanuals.com. All Manuals Search And Download.
Limitations of This Alarm System
While this system is an advanced design security system, it does not offer guaranteed protection against burglary, fire, or
other emergency. Any alarm system, whether commercial or residential, is subject to compromise or failure to warn for a
variety of reasons. For example:
• Intruders may gain access through unprotected openings or have the technical sophistication to bypass an alarm
sensor or disconnect an alarm warning device.
• Intrusion detectors (e.g., passive infrared detectors), smoke detectors, and many other sensing devices will not work
without batteries, or if the batteries are not put in properly. Devices powered solely by AC will not work if their AC power
supply is cut off for any reason, however briefly.
• Signals sent by wireless transmitters may be blocked or reflected by metal before they reach the alarm receiver. Even if
the signal path has been recently checked during a weekly test, blockage can occur if a metal object is moved into the
path.
• A user may not be able to reach a panic or emergency button quickly enough.
• While smoke detectors have played a key role in reducing residential fire deaths, they may not activate or provide early
warning for a variety of reasons in as many as 35% of all fires. Some of the reasons smoke detectors used in
conjunction with the System may not work are as follows: Smoke detectors may not sense fires that start where smoke
cannot reach the detectors, such as in chimneys, in walls, or roofs, or on the other side of closed doors. Smoke
detectors also may not sense a fire on another level of a residence or building. A second-floor detector, for example,
may not sense a first-floor or basement fire. Moreover, smoke detectors have sensing limitations. No smoke detector
can sense every kind of fire every time. In general, detectors may not always warn about fires caused by carelessness
and safety hazards like smoking in bed, violent explosions, escaping gas, improper storage of flammable materials,
overloaded electrical circuits, children playing with matches, or arson. Depending on the nature of the fire and/or the
location of the smoke detectors, the detector, even if it operates as anticipated, may not provide sufficient warning to
allow all occupants to escape in time to prevent injury or death.
• Passive Infrared Motion Detectors can detect intrusion only within the designed ranges as diagrammed in their
Installation Manual. Passive Infrared Detectors do not provide volumetric area protection. They do create multiple
beams of protection, and intrusion can only be detected in unobstructed areas covered by the beams. They cannot
detect motion or intrusion that takes place behind walls, ceilings, floors, closed doors, glass partitions, glass doors or
windows. Mechanical tampering, masking, painting or spraying, of any material on the mirrors, windows or any part of
the optical system can reduce their detection ability. Passive Infrared Detectors sense changes in temperature;
however, as the ambient temperature of the protected area approaches the temperature range of 90º to 104º
Fahrenheit (32º to 40º Celsius), the detection performance can decrease.
• Alarm warning devices such as sirens, bells or horns may not alert people or wake up sleepers who are located on the
other side of closed or partly open doors. If warning devices sound on a different level of the residence from the
bedrooms, then they are less likely to waken or alert people inside the bedrooms. Even persons who are awake may
not hear the warning if the alarm is muffled by noise from a stereo, radio, air conditioner, other appliances, or by
passing traffic. Finally, alarm warning devices, however loud, may not warn hearing-impaired people or waken deep
sleepers.
• Telephone lines needed to transmit alarm signals from a premises to a central monitoring station may be out of service
or temporarily out of service. Telephone lines are also subject to compromise by sophisticated intruders.
However, even if the system responds to the emergency as intended, occupants may have insufficient time to protect
themselves from the emergency situation. In the case of a monitored alarm system, authorities may not respond
appropriately.
• This equipment, like other electrical devices, is subject to component failure. Even though this equipment is designed
to last as long as 20 years, the electronic components could fail at any time.
The most common cause of an alarm system not functioning when an intrusion or fire occurs is inadequate maintenance.
This alarm system should be tested weekly to make sure all sensors are working properly.
Installing an alarm system may make one eligible for lower insurance rates, but an alarm system is not a substitute for
insurance. Homeowners, property owners and renters should continue to act prudently in protecting themselves and
continue to insure their lives and property.
We continue to develop new and improved protection devices. Users of alarm systems owe it to themselves and their
loved ones to learn about these developments.
- 31 -
Download from Www.Somanuals.com. All Manuals Search And Download.
ONE YEAR LIMITED WARRANTY
Honeywell International Inc., acting through its Security & Custom Electronics business ("Seller"), 165 Eileen
Way, Syosset, New York 11791, warrants its security equipment (the "product") to be free from defects in
materials and workmanship for one year from date of original purchase, under normal use and service. Seller's
obligation is limited to repairing or replacing, at its option, free of charge for parts, labor, or transportation, any
product proven to be defective in materials or workmanship under normal use and service. Seller shall have no
obligation under this warranty or otherwise if the product is altered or improperly repaired or serviced by
anyone other than the Seller. In case of defect, contact the security professional who installed and maintains
your security equipment or the Seller for product repair.
This one year Limited Warranty is in lieu of all other express warranties, obligations or liabilities. THERE ARE
NO EXPRESS WARRANTIES, WHICH EXTEND BEYOND THE FACE HEREOF. ANY IMPLIED
WARRANTIES, OBLIGATIONS OR LIABILITIES MADE BY SELLER IN CONNECTION WITH THIS
PRODUCT, INCLUDING ANY IMPLIED WARRANTY OF MERCHANTABILITY, OR FITNESS FOR A
PARTICULAR PURPOSE OR OTHERWISE, ARE LIMITED IN DURATION TO A PERIOD OF ONE YEAR
FROM THE DATE OF ORIGINAL PURCHASE. ANY ACTION FOR BREACH OF ANY WARRANTY, IN-
CLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY OF MERCHANTABILITY, MUST BE
BROUGHT WITHIN 12 MONTHS FROM DATE OF ORIGINAL PURCHASE. IN NO CASE SHALL SELLER
BE LIABLE TO ANYONE FOR ANY CONSEQUENTIAL OR INCIDENTAL DAMAGES FOR BREACH OF
THIS OR ANY OTHER WARRANTY, EXPRESS OR IMPLIED, OR UPON ANY OTHER BASIS OF LIABILITY
WHATSOEVER, EVEN IF THE LOSS OR DAMAGE IS CAUSED BY THE SELLER'S OWN NEGLIGENCE
OR FAULT. Some states do not allow limitation on how long an implied warranty lasts or the exclusion or
limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you.
Seller does not represent that the product may not be compromised or circumvented; that the product will
prevent any personal injury or property loss by burglary, robbery, fire or otherwise; or that the product will in all
cases provide adequate warning or protection. Buyer understands that a properly installed and maintained
alarm may only reduce the risk of a burglary, robbery, fire or other events occurring without providing an alarm,
but it is not insurance or a guarantee that such will not occur or that there will be no personal injury or property
loss as a result. CONSEQUENTLY, SELLER SHALL HAVE NO LIABILITY FOR ANY PERSONAL INJURY,
PROPERTY DAMAGE OR OTHER LOSS BASED ON A CLAIM THE PRODUCT FAILED TO GIVE WARN-
ING. HOWEVER, IF SELLER IS HELD LIABLE, WHETHER DIRECTLY OR INDIRECTLY, FOR ANY LOSS
OR DAMAGE ARISING UNDER THIS LIMITED WARRANTY OR OTHERWISE, REGARDLESS OF CAUSE
OR ORIGIN, SELLER'S MAXIMUM LIABILITY SHALL NOT IN ANY CASE EXCEED THE PURCHASE PRICE
OF THE PRODUCT, WHICH SHALL BE THE COMPLETE AND EXCLUSIVE REMEDY AGAINST SELLER.
This warranty gives you specific legal rights, and you may also have other rights which vary from state to state.
No increase or alteration, written or verbal, to this warranty is authorized.
165 Eileen Way, Syosset, New York 11791
Copyright © 2004 Honeywell International Inc.
ÊN9939V54Š
N9939V5 4/04 Rev. A
Download from Www.Somanuals.com. All Manuals Search And Download.
|