Honeywell Home Security System 2 Partitioned Security System User Manual

$'(0&2ꢀ9,67$ꢁꢂꢃꢀ  
ꢀꢁ3DUWLWLRQHGꢂ6HFXULW\ꢂ6\VWHPꢂ  
3URJUDPPLQJ *XLGH  
N7001PRV5 5/04 Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Recommended Programming Procedure  
The following is a step-by-step procedure recommended for programming your VISTA-40 system.  
1. Set the keypads (and other peripheral devices) to the appropriate addresses.  
2. Set factory defaults by pressing 97.  
This will automatically enable keypad addresses 00-01, so be sure at least one keypad is set to one of these  
addresses.  
3. Program system-wide (global) data fields.  
Using the programming form as a guide, enter program mode and program all system-wide programming  
fields. These options affect the entire system, regardless of partitions. They include control options,  
downloader and dialer options, RF options, event logging options, etc. Refer to the Program Field Index for a  
listing of the program fields and their function.  
Note that field 200 (number of partitions) must be programmed before continuing.  
4. Program partition-specific fields.  
When the system-wide fields have been programmed, program all partition-specific programming fields by  
first pressing 91 to select a partition (while still in data field program mode). Then enter the first partition-  
specific field number 09. When you are finished, the next partition-specific field is automatically displayed.  
Partition-specific fields can have different values for each partition. To program the fields for the next partition,  
press 91, enter the desired partition number, then enter field 09. Refer to the MECHANICS OF  
PROGRAMMING section in the ADEMCO VISTA-40 Installation and Setup Guide for detailed instructions.  
5. Use #93 Menu Mode for device programming.  
Refer to Device Programming in this guide to assign keypad ID numbers and default partitions for each  
keypad, and to selectively suppress certain keypad sounding options. Also use this mode to assign RF  
receivers, relay modules, and the VIP module.  
6. Use #93 Menu Mode for zone programming.  
Refer to Zone Programming in this guide to program zone response types, assign right loop zones and  
wireless zones, assign zones to partitions, and to program alarm report codes.  
7. Use #93 Menu Mode for programming relays.  
Refer to Relay Programming in this guide to program desired relay operation.  
8. Program Communication options.  
Refer to System Communication section in the ADEMCO VISTA-40 Installation and Setup Guide for detailed  
instructions. Then use #93 menu mode to program report codes.  
9. Use #93 Menu Mode for programming alpha descriptors.  
Refer to Alpha Programming in this guide to enter zone and partition descriptors and a custom installer’s  
message.  
10. Use #93 Menu Mode for relay voice descriptors and custom word substitutes.  
Refer to Relay Voice Descriptors in this guide for further instructions for programming relay descriptors to be  
annunciated by the VIP module, as well as the Custom Index section for custom word substitutes.  
11. Define user access codes.  
Refer to User Access Codes in the ADEMCO VISTA-40 Installation and Setup Guide to program authority  
level, O/C reporting option, partition assignments, and RF key assignments for each user.  
12. Exit Programming Mode.  
Exit programming mode by pressing either 98 or 99. Additional entries of 99 are required if the exit is  
being done from fields 100 and above.  
To prevent re-access to programming mode using the Installer’s code, use 98. The only way to re-access  
programming mode is by depressing both the [] and [#] keys at the same time within 30 seconds of power-  
up.  
Exiting by using 99 always allows reentry into programming mode using the Installer code. Either way of  
exiting allows access via downloading. Note that if local programming lockout is set via downloading,  
programming mode cannot be entered at the keypad.  
3 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Program Field Index  
On the following pages, the programming fields have been arranged in numerical order. Use this index to cross-reference the  
fields on the programming form.  
Field  
Group  
Field Group  
Communications  
Field Group  
# 93 Menu Mode  
*00  
*02  
*03  
*04  
*05  
*09  
*10  
*11  
*12  
*13  
*14  
*15  
*16  
*17  
*19  
*20  
*21  
*22  
*23  
*24  
*25  
*26  
*27  
*28  
*29  
*30  
*31  
*32  
*33  
*34  
*35  
*36  
*37  
*38  
*39  
*40  
*41  
*42  
*43  
*44  
*45  
*46  
*47  
*48  
System-Wide  
*49  
*50  
*51  
*52  
*53  
*54  
*55  
*56  
*57  
*58  
*59  
*60  
*61  
*62  
*63  
*64  
*65  
*66  
*67  
*68  
*69  
*70  
*71  
*72  
*73  
*74  
*75  
*76  
*77  
*78  
*79  
*80  
*81  
*82  
*83  
*84  
*85  
*86  
*87  
*88  
*89  
*90  
1*01  
1*02  
1*03  
1*04  
1*05  
1*06  
1*07  
1*08  
1*09  
1*28  
1*29  
1*30  
1*31  
1*32  
1*33  
1*34  
1*40  
1*41  
1*43  
1*44  
1*45  
1*46  
1*47  
1*48  
1*49  
1*52  
1*53  
1*57  
1*58  
1*60  
1*66  
1*70  
1*71  
1*74  
1*75  
1*76  
2*00  
2*01  
2*02  
2*17  
2*18  
2*19  
2*20  
2*21  
# 93 Menu Mode  
# 93 Menu Mode  
# 93 Menu Mode  
# 93 Menu Mode  
Partition-Specific  
Partition-Specific  
Partition-Specific  
Partition-Specific  
Partition-Specific  
System-Wide  
System-Wide  
Partition-Specific  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
Partition-Specific  
Partition-Specific  
System-Wide  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Partition-Specific  
Partition-Specific  
System-Wide  
# 93 Menu Mode  
# 93 Menu Mode  
# 93 Menu Mode  
# 93 Menu Mode  
# 93 Menu Mode  
# 93 Menu Mode  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
Communications  
Communications  
Communications  
Communications  
Partition-Specific  
System-Wide  
Partition-Specific  
System-Wide  
Partition-Specific  
System-Wide  
System-Wide  
Partition-Specific  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
Partition-Specific  
System-Wide  
System-Wide  
System-Wide  
System-Wide  
Partition-Specific  
System-Wide  
Partition-Specific  
System-Wide  
System-Wide  
Communications  
Communications  
System-Wide  
Partition-Specific  
Communications  
Communications  
Partition-Specific  
Communications  
Communications  
System-Wide  
System-Wide  
System-Wide  
Partition-Specific  
Partition-Specific  
Communications  
System-Wide  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Communications  
Partition-Specific  
Partition-Specific  
Communications  
Partition-Specific  
# 93 Menu Mode  
# 93 Menu Mode  
4 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VISTA-40 Programming Form  
Some fields are programmed for each partition (shown as shaded fields). If you are programming a multiple-partition system,  
see the Partition-Specific Fields section for programming these fields. Standard default (*97) values are shown in brackets.  
*00 INSTALLER CODE  
| | |  
*25 BURG.TRIGGER FOR RESPONSE TYPE 8 [1]  
Enter 4 digits, 0-9 [4140]  
1=enable; 0=disable  
*02 *05 RESPONSE TYPES FOR ZONES  
*26 INTELLIGENT TEST REPORTING  
[0]  
Skip these fields. Use #93 Menu Mode, Zone  
Programming to program the response types.  
1=yes (no report sent if any other report was recently sent);  
0=no (send report at programmed interval, field *27)  
Must be 0 for UL installations.  
*09 ENTRY DELAY #1  
[02]  
[03]  
[06]  
|
|
|
00, 02-15 times 15 seconds  
Maximum "03" for UL.  
*27 TEST REPORT INTERVAL  
[024]  
| |  
Enter interval in hours, 001-199; 000=no report;  
Max. 024 for UL installations.  
*10 EXIT DELAY #1  
00, 03-15 times 15 seconds  
Maximum "04" for UL installations.  
*28 POWER UP IN PREVIOUS STATE  
[1]  
[1]  
[0]  
1=yes; 0=no; "1" for UL installations.  
*11 ENTRY DELAY #2  
*29 QUICK ARM  
00, 02-15 times 15 seconds (must be longer than Entry Delay  
#1). Maximum "03" for UL installations.  
1=yes; 0=no  
*30 TOUCHTONE OR ROTARY DIAL  
*12 EXIT DELAY #2  
[08]  
|
1=TouchTone; 0=rotary  
00, 03-15 times 15 seconds (must be longer than Exit Delay  
#1). Maximum "04" for UL installations.  
*31 PABX ACCESS CODE  
|
|
|
|
|
|
|
|
*13 ALARM SOUNDER DURATION  
[04]  
|
00-09; B-F (11-15)  
01-15 times 2 minutes. Must be minimum 16 minutes for UL  
installations.  
*32 PRIM. SUBS. ACCT #  
Enter 00-09; B-F (11-15) [15 15 15 15]  
*14 ZONE 9 RESPONSE TIME  
[0]  
*33 PRIMARY PHONE NUMBER  
Enter 1 for fast response time 10ms  
Enter 0 for normal response time 350ms.  
Must be 0 for UL installations.  
*15 KEYSWITCH ASSIGNMENT  
[0]  
[0]  
Enter 0-9 for each digit. Enter #11 for *, #12 for #,  
#13 for 2 second pause  
Enter partition in which keyswitch used,  
1-2; 0=disable  
*34 SECONDARY PHONE NUMBER  
*16 CONFIRMATION OF ARMING DING  
1=enable; 0=disable.  
Must be "1" for UL Installations.  
*17 AC LOSS KEYPAD SOUNDING  
[0]  
[0]  
Enter 0-9 for each digit. Enter #11 for *, #12 for #,  
#13 for 2 second pause  
1=yes; 0=no  
*35 DOWNLOAD PHONE NO.  
*19 RANDOMIZE AC LOSS REPORT  
1=10-40 min; 0=normal report (about 2 min. after AC loss).  
*20 VIP MODULE PHONE CODE  
|
|
Enter 0-9 for each digit. Enter #11 for *, #12 for #,  
#13 for 2 second pause  
Enter 01 - 09 for the first digit; enter  
11 for *or 12 for #for the second digit.  
Must be set to "0" for UL installations.  
[00],  
[11]  
*36 DOWNLOAD ID NO.  
|
|
|
|
|
|
|
|
*21 PREVENT FIRE TIMEOUT  
[0]  
Enter 00-09; A-F (10-15) [15 15 15 15 15 15 15 15]  
1=No timeout; 0=Timeout.  
*37 DOWNLOAD COMMAND ENABLES  
*22 KEYPAD PANIC ENABLES  
[001]  
0
1=enable; 0=disable  
995 996 999  
Dlr ShtdwnSys ShtdwnNot UsedRmt BypRmt DisarmRmt ArmUpld PgmDwnld Pgm  
See field 1*53 for Callback disable option; [1=enable];  
0=disable. For UL installations, all entries must be "0."  
*23 MULTIPLE ALARMS  
[1]  
1=yes; 0=no  
*38 PREVENT ZONE XX BYPASS  
[00]  
|
*24 IGNORE EXPANSION ZONE TAMPER  
[0]  
01-64; 00 if all zones can be bypassed  
1=Ignore; 0=Enable tamper for RF and RPMs.  
Must be "0" for UL installations if using these devices.  
5 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*58 SUPERVISORY AND RESTORE CODES FOR ZONES  
*39 ENABLE OPEN/CLOSE REPORT FOR  
[0]  
01-16. Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]  
INSTALLER CODE 1=enable; 0=disable  
|
|
Trbl  
|
|
Byp  
|
*40 OPEN/CLOSE REPORT FOR KEYSWITCH [0]  
Alarm Rst  
Trbl Rst  
Byp Rst  
1=enable; 0=disable  
*59 *62 ALARM REPORT CODES & ID DIGITS FOR  
ZONES 17-32.  
*41 NORMALLY CLOSED or EOLR (Zones 2-8) [0]  
Skip these fields. Use #93 Menu Mode, Zone  
Programming to program the report codes.  
1=N.C.loops; 0=EOLR supervision.  
Must be "0" for UL installations.  
*63 SUPERVISORY AND RESTORE CODES FOR ZONES  
17-32. Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]  
*42 DIAL TONE PAUSE  
[0]  
[1]  
|
|
|
|
|
0=5 seconds; 1=11 seconds; 2=30 seconds.  
Must be "0" UL Installations.  
Alarm Rst  
Trbl  
Trbl Rst  
Byp  
Byp Rst  
*43 DIAL TONE DETECTION  
*64 *67 ALARM REPORT CODES & ID DIGITS FOR  
ZONES 33-48.  
1=wait for true dial tone; 0=pause, then dial  
Skip these fields. Use #93 Menu Mode, Zone  
Programming to program the report codes.  
*44 RING DETECTION COUNT  
[00]  
|
*68 SUPERVISORY AND RESTORE CODES FOR ZONES  
01-14; 15=answering machine; 00=no detection.  
Must be "00" for UL Burglary.  
33-48. Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]  
|
|
|
|
|
*45 PRIMARY FORMAT  
[1]  
Alarm Rst  
Trbl  
Trbl Rst  
Byp  
Byp Rst  
0=Low Speed; 1=Contact ID; 2=ADEMCO High Speed;  
3= ADEMCO Express  
*69 *72 ALARM REPORT CODES & ID DIGITS FOR  
ZONES 49-64.  
*46 LOW SPEED FORMAT (Primary)  
[0]  
Skip these fields. Use #93 Menu Mode, Zone  
Programming to program the report codes.  
0= ADEMCO Low Speed; 1=Sescoa/Radionics  
*73 SUPERVISORY AND RESTORE CODES FOR ZONES  
*47 SECONDARY FORMAT  
[1]  
49-64. Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]  
0=Low Speed; 1=Contact ID; 2= ADEMCO High Speed;  
3= ADEMCO Express  
|
|
|
|
|
Alarm Rst  
Trbl  
Trbl Rst  
Byp  
Byp Rst  
*48 LOW SPEED FORMAT (Sec.)  
[0]  
*74 *77 ALARM REPORT CODES & ID DIGITS FOR  
0= ADEMCO Low Speed; 1=Sescoa/Radionics  
ZONES 87-99.  
Skip these fields. Use #93 Menu Mode, Zone  
Programming to program the report codes.  
*49 CHECKSUM VERIFICATION  
[0] [0]  
1=yes; 0=no  
Prim  
Sec  
*78 SUPERVISORY AND RESTORE CODES FOR ZONES  
87-99. Enter 00-09; B-F (11-15). Default = [00 00 00 00 00]  
*50 SESCOA/RADIONICS SELECT  
[0]  
[0]  
1=Sescoa; 0=Radionics  
|
|
|
|
|
Alarm Rst  
Trbl  
Trbl Rst  
Byp  
Byp Rst  
*51 DUAL REPORTING  
1=yes; 0=no If used with Spilt Reporting "1" option (1*34),  
alarms and alarm restores go to both primary & secondary  
numbers, while all other reports go to secondary only. If used  
with Split Reporting "2" option, alarms and alarm restores go to  
both, open/close and test messages go to secondary only,  
while all other reports go to primary.  
ZONE TYPE RESTORE ENABLES  
*79 FOR ZONE TYPES 1-8  
1
2
3
4
5
6
7
8
*52 STANDARD/EXPANDED REPORT FOR PRIMARY  
1=enable; [0=disable]  
*80 FOR TYPES 9, 10  
[0 0 0 0 0 0]  
Alarm Rstr Byp Trbl O/C LoBat  
0=standard; 1=expanded;  
9
10  
1=enable; [0=disable]  
Note: Expanded overrides 4+2 format.  
*53 STANDARD/EXPANDED REPORT FOR SECONDARY  
[0 0 0 0 0 0]  
Alarm Rstr Byp Trbl O/C LoBat  
0=standard; 1=expanded;  
Note: Expanded overrides 4+2 format.  
*54 *57 ALARM REPORT CODES & ID DIGITS FOR  
ZONES 01-16.  
Skip these fields. Use #93 Menu Mode, Zone  
Programming to program the report codes.  
6 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
*80 *81  
SYSTEM NON-ALARM CODES  
Enter 00-09; B-F (11-15).  
1*30 RF RCVR CHECK-IN INTERVAL  
[06]  
[12]  
|
|
Default = 00 for all reports  
02-15 times 2 hours; 00 disables supervision  
*80 1st Digit  
*81 2nd Digit  
1*31 RF XMITTER CHECK-IN INTERVAL  
|
|
|
|
|
|
|
|
|
|
|
Close  
02-15 times 2 hours; 00 disables transmitter supervision  
|
|
|
|
|
|
|
|
|
1*33 TOUCHTONE W/ROTARY BACKUP  
[0]  
Open  
1=enable; 0=disable  
Low Battery  
1*34 COMM. SPLIT REPORTING  
[0]  
Low Battery Restore  
AC Loss  
0=no; 1=alarms and alarm restores primary, others secondary;  
2=open/close, test secondary, others primary. See 51 for  
comments if using with dual reporting.  
1*40 1*41 NON-ALARM DIALER CODES  
Enter 00-09; B-F (11-15).  
AC Restore  
Test  
Default = 00 for all reports  
1*40 1st Digit  
1*41 2nd Digit  
|
|
Armed STAY  
Power Up  
|
|
Time/Date Set or Event Log Reset  
Cancel  
1*43 PERM. KEYPAD BACKLIGHT  
[0]  
Program Tamper  
1=enable; 0=disable When disabled, display lights when any  
key is pressed, and turns off after period of keypad inactivity.  
*83 FIRST TEST REPORT TIME  
|
|
|
1*44 WIRELESS KEYPAD TAMPER  
[0]  
[Day 00; hour 12; min 00] Days 01-07 Hours 00-23 Min 00-  
59; 00 in all boxes = instant (Day 01= Monday)  
DETECTION  
1=enable; 0=disable.  
Must be "0" for UL installations.  
*84 SWINGER SUPPRESSION  
[03]  
|
01-15 alarms  
Must be "00" (disabled) for UL.  
*85 ENABLE DIALER REPORTS FOR PANICS & DURESS  
1*45 EXIT DELAY SOUNDING  
[0]  
1=enable; 0=disable. Produces quick beeping during exit  
delay if enabled.  
NOTE: See page 32, SOUND OPTION, prompt for  
disabling the entry/exit beeps on individual keypads.  
1=enable; [0=disable]  
995 996 999 Duress  
1*46 AUXILIARY OUTPUT MODE  
[0]  
*87 ENTRY WARNING  
[1]  
Enter 0 for ground start output.  
Enter 1 for open/close trigger.  
Enter 2 for keypad-like sounding.  
Enter 3 if AAV module is being used.  
NOTE: Only one of the above options may be active within  
the system.  
1=continuous; 0=3 beeps  
*86 4208 MODULE ZONE ASSIGMENT  
[0]  
1 = allows 8 zones on one module (10-17), but prevents any  
other polling loop expansion. 0 = all other setups.  
*88 BURG. ALARM COMM. DELAY  
[0]  
1*47 CHIME ON EXTERNAL SIREN  
[0]  
1=16 seconds; 0=no delay  
Must be "0" for UL installations.  
1=enable; 0=disable  
1*48 WIRELESS KEYPAD ASSIGNMENT  
[0]  
*89 RESTORE REPORT TIMING  
[0]  
0=disable; enter partition in which RF keypad used, 1-2.  
Must be "0" for UL installations.  
0=Instant; 1=At bell timeout if zone is restored; 2=when  
system is disarmed. Must be "0" for UL installations.  
1*49 SUPPRESS TX SUPERVISION SOUND  
[1]  
*90 SEC. SUBS. ACCT #  
|
|
|
|
1=disable; 0=enable.  
Must be "0" for UL installations.  
Enter 00-09; B-F (11-15) [15 15 15 15]  
2nd Page Programming Fields (press *94)  
1*52 SEND CANCEL IF ALARM + OFF  
[0]  
[0]  
[0]  
1*01 1*09 ASSIGN RESPONSE TYPE FOR ZONES.  
1=no restriction; 0=within bell timeout period only  
Skip these fields. Use #93 Menu Mode, Zone  
Programming to program the response types.  
1*53 DOWNLOAD CALLBACK  
MISCELLANEOUS WIRELESS OPTIONS  
1=callback not required; 0=callback required.  
Fields 1*28 - 1*31 are not applicable for UL installations.  
1*57 5800 RF BUTTON GLOBAL ARM  
1*28 RF TX LOW BATTERY SOUND  
[0]  
1=enable; 0=disable  
1=immediate; 0=when disarmed  
1*29 RF TX LOW BATTERY REPORTING  
[0]  
1=enable; 0=disable  
7 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1*58 5800 RF BUTTON FORCE ARM  
[0]  
2*02 DAYLIGHT SAVING TIME  
[1, 5]  
|
Enter "1" to enable. If a zone is faulted after pressing button,  
keypad will beep once. Pressing the button again within 4  
sec. bypasses the zone. Enter "0" to disable.  
Must be "0" for UL installations.  
START/END WEEKEND  
Enter 1-7. 1=first; 2=second; 3=third; 4=fourth; 5=last;  
6=next to last; 7=3rd from last [1,5]  
Start | End  
2*17 NUMBER OF CODES PER PARTITION  
1*60 ZONE 5 AUDIO ALARM VERIFICATION  
[0]  
[0]  
|
|
Enter 1 If 2-way audio (AAV) is being used; Enter 0 if it is  
not.  
Enter 01-69 for each partition. The total must not exceed 70.  
Must be "0" for UL installations.  
2*18 ENABLE GOTO FOR THIS PARTITION  
[0]  
[0]  
1=Allow log-on from other partition; 0=disable  
1*66 SILENCE BELLS DURING AAV  
[0]  
Enter 1 to alarm sounders during AAV session.  
Enter 0 to have alarm sounders continue to sound during  
AAV session. Must be 0 for UL installations.  
2*19 USE PARTITION DESCRIPTORS  
0=disable; 1=enable  
1*70 EVENT LOG TYPES  
2*20 ENABLE J7 TRIGGERS FOR PARTITION [1]  
0=disable for displayed partition; 1=enable for displayed  
partition  
[1 0 0 0 1]  
Alarm Chk Byp O/C Syst  
2*21 ENABLE SUPERVISION PULSES FOR LRR  
1=enable; 0=disable  
TRIGGER OUTPUTS  
[000]  
| |  
1*71 12/24 HOUR TIME STAMP FORMAT  
[0]  
Used for supervised connection to 7920SE.  
F
B
P
0=12 hour; 1=24 hour  
Enter 0 to disable or 1 to enable the listed outputs.  
F= Fire; B= Burglary; P= Silent Panic/Duress.  
Must be 1 for UL. Installations.  
1*74 RELAY TIMEOUT XXX MINUTES [000]  
| |  
Enter the relay timeout, 000-127 in multiples of 2 minutes,  
desired for #93 Menu Mode Relay Programming output  
command "56."  
SUMMARY OF PROGRAMMING COMMANDS  
To enter program mode, enter installer code + [8] + [0] +  
[0]  
1*75 RELAY TIMEOUT YYY SECONDS [000]  
| |  
Enter the relay timeout, 000-127 seconds for #93 Menu  
Mode Relay Programming command "57."  
To set standard defaults, press *97  
To change to next page of program fields, press *94  
To return to previous set of fields, press *99  
To erase account and phone number field entries,  
press [*] + field number + [*]  
To assign zone descriptors, press #93 + follow menu  
prompts  
To add custom words, press #93 + follow menu prompts  
To enter Installer's Message, press #93 + follow menu  
prompts  
1*76 ACCESS CONTROL RELAY  
[00]  
|
Relay will be pulsed for 2 seconds whenever code + [0] is  
pressed. Enter 00-08; 00=none.  
Must be "00" for UL.  
3rd Page Programming Fields (press *94)  
2*00 NUMBER OF PARTITIONS  
[1]  
Enter 1-2  
To exit program mode, enter *99 OR *98: *99 allows re-  
access to programming mode by installer code. *98  
prevents re-access to programming mode by installer  
code.  
2*01 DAYLIGHT SAVING TIME [04, 10]  
|
|
START/END MONTH  
00-12; if no daylight saving time, enter 00,00  
Start End  
8 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Partition-Specific Fields  
(Duplicate this page for each partition in the installation.)  
To program these fields,  
1. Press *91 to select a partition.  
2. Enter a partition-specific field number (ex. *09).  
3. Make the required entry.  
4. Repeat steps 1-3 for the other partition in the system.  
PARTITION #____ PROGRAM FIELDS  
1st Page Fields  
*88 BURG. ALARM COMM. DELAY  
[0]  
*09 ENTRY DELAY #1  
[02]  
[04]  
[06]  
[08]  
[04]  
|
|
|
|
|
1=16 seconds; 0=no delay. Must be "0" for UL installations.  
00, 02-15 times 15 seconds.  
Maximum 03 for UL Listed installations.  
*90 SEC. SUBS. ACCT #  
|
|
|
|
Enter 00-09; B-F (11-15) [15 15 15 15]  
2nd Page Fields  
*10 EXIT DELAY #1  
00, 03-15 times 15 seconds.  
Maximum 04 for UL Listed installations.  
1*43 PERM. KEYPAD BACKLIGHT  
[0]  
1=enable; 0=disable When disabled, display lights when  
any key is pressed, and turns off after period of keypad  
inactivity.  
*11 ENTRY DELAY #2  
00, 02-15 times 15 seconds.  
Maximum 03 for UL installations.  
1*45 EXIT DELAY SOUNDING  
[0]  
*12 EXIT DELAY #2  
1=enable; 0=disable. Produces quick beeping during exit  
delay if enabled.  
00, 03-15 times 15 seconds.  
Maximum 04 for UL installations.  
1*47 CHIME ON BELL 1  
[0]  
*13 ALARM SOUNDER DURATION  
1=enable; 0=disable  
01-15 times 2 minutes.  
Must be minimum 16 minutes for UL installations.  
1*52 SEND CANCEL IF ALARM + OFF  
[0]  
*16 CONFIRMATION OF ARMING DING  
[0]  
1=no restriction; 0=within Bell Timeout period only  
1=enable; 0=disable.  
Must be "1" for UL installations.  
1*76 ACCESS CONTROL RELAY FOR PART.[00]  
|
Relay will be pulsed for 2 seconds whenever code + [0] is  
pressed. Enter 00-08; 00=none. Must be "00" for UL installs.  
3rd Page Fields  
*22 KEYPAD PANIC ENABLES  
[001]  
1=enable; 0=disable  
995 996 999  
[1]  
2*18 ENABLE GOTO FOR THIS PARTITION  
[0]  
*23 MULTIPLE ALARMS  
1=Allow log-on from other partitions; 0=disable  
1=yes; 0=no. Must be 1 for UL installations.  
2*20 ENABLE J7 TRIGGERS BY PARTITION  
[1]  
*29 QUICK ARM  
[1]  
0=disable; 1=enable for  
1=yes; 0=no  
*32 PRIM. SUBS. ACCT #  
|
|
|
|
SUMMARY OF PROGRAMMING COMMANDS  
Enter 00-09; B-F (11-15) [15 15 15 15]  
To enter program mode, enter installer code + [8] + [0] +  
[0]  
*38 PREVENT ZONE XX BYPASS  
[00]  
|
|
To set standard defaults, press *97  
To change to next page of program fields, press *94  
To return to previous set of fields, press *99  
To erase account and phone number field entries,  
press [*] + field number + [*]  
To assign zone descriptors, press #93 + follow menu  
prompts  
To add custom words, press #93 + follow menu prompts  
To enter Installer's Message, press #93 + follow menu  
prompts  
001-64; 000 if all zones can be bypassed  
*39 ENABLE OPEN/CLOSE REPORT  
[1]  
FOR INSTALLER CODE  
1=enable; 0=disable  
*84 SWINGER SUPPRESSION  
[03]  
01-15 alarms; Must be "00" (disabled) for UL installations.  
*85 ENABLE DIALER REPORTS FOR PANICS & DURESS  
1=enable; [0=disable]  
995 996 999 Duress  
To exit program mode, enter *99 OR *98: *99 allows re-  
access to programming mode by installer code. *98  
prevents re-access to programming mode by installer  
code.  
*87 ENTRY WARNING  
[1]  
1=continuous; 0=3 beeps  
9 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Programming With #93 Menu Mode  
NOTE: The following field should be preset before beginning: 2*00 Number of Partitions. In addition, receivers should  
be programmed via Device programming.  
After programming all system related programming fields in the usual way, press #93 while still in programming mode to  
display the first choice of the menu driven programming functions. Press 0 (NO) or 1 (YES) in response to the displayed menu  
selection. Pressing 0 will display the next choice in sequence.  
For UL installations, verify that the audio alarm verification feature is disabled.  
U
L
#93 MENU MODE KEY COMMANDS  
The following is a list of commands used while in the menu mode.  
#93  
[4]  
[#]  
Enters Menu mode  
Serves as ENTER key. Press to have keypad accept entry.  
Backs up to previous screen.  
0
Press to answer NO  
1
Press to answer YES  
01-09  
00  
All data entries are either 1-digit or 2-digit entries.  
Exits menu mode, back into field programming mode, when entered at the first question for each category.  
Menu selections are as follows:  
PROMPT  
EXPLANATION  
For programming the following:  
ZONE PROG?  
1 = YES 0 = NO  
Zone Number  
Zone Response Type  
Partition Number for Zone  
Dialer report code for zone  
Input Device Type for zone (whether RF, polling loop, etc.)  
Enrolling serial numbers of 5800 Series transmitters & serial polling loop devices into the system.  
0
Same as Zone Programming except:  
EXPERT MODE?  
1 = YES 0 = NO  
Done with a minimum number of keystrokes.  
0
0
Can program wireless keys using pre-defined templates.  
For entering alpha descriptors for the following:  
ALPHA PROG?  
1 = YES 0 = NO  
Zone Descriptors  
Installer's Message  
Custom Words  
Partition Descriptors  
Relay Descriptors  
For defining the following device characteristics for addressable devices, including keypads, RF receivers  
(5881), output relay modules (4204), and 4285/4286 VIP Module:  
DEVICE PROG?  
1 = YES 0 = NO  
0
Device Address  
Device Type  
Keypad Options (incl. partition assignment)  
RF House ID  
For defining relay functions.  
RELAY PROG?  
1 = YES 0 = NO  
0
0
0
For entering voice descriptors for relays to be used with the 4285/4286 VIP Module.  
For creating custom word substitutes for VIP Module annunciation.  
RLY VOICE DESCR?  
1 = YES 0 = NO  
CUSTOM INDEX ?  
1 = YES 0 = NO  
10 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Zone Programming  
If using 5800 Series transmitters, do not the install batteries until you are ready to enroll them. After enrolling  
the transmitter, the battery need not be removed. This is to prevent enrolling the wrong serial number.  
PROMPT  
EXPLANATION  
Press 1 to enter ZONE PROGRAMMING mode. The following screens appear. Press [] to display the next  
screen. Press # to display a previous screen.  
ZONE PROG?  
1 = YES 0 = NO  
0
0
This prompt appears once upon entering Zone Programming Mode.  
If Yes,Confirmation prompts will be displayed after the devices Serial and Loop numbers have been  
entered later.  
SET TO CONFIRM?  
1 = YES 0 = NO  
Enter the 2-digit zone number to be programmed, as follows:  
Protection Zones = 0164  
ENTER ZONE NO.  
00 = QUIT  
10  
System Supervisory Zones = 88, 89, 90, 91, 92 (duress), 97  
Keypad Panic Zones = 95, 96, 99  
Zone 10 entered  
Press [] to continue.  
This display appears, showing a summary of the zone's current programming. ZT = Zone Type, P =  
Partition, RC = Report Code, In = the input type of device, and L = the device's loop number to which the  
sensor is connected.  
10 ZT  
00  
P
RC In L  
10 00 1  
1
Some devices can support more than one zone by means of individual loops (for example, 5801, 5804,  
5816, 5817, etc.). If the zone is not programmed, the display appears as shown here. If you are checking a  
zone's programming, and it is programmed satisfactorily, press [#] to back up one step and enter another  
zone number, if desired.  
Press [] to continue.  
Each zone must be assigned a zone type, which defines the way in which the system responds to faults in  
that zone. Refer to the Zone Type Definitions section in the ADEMCO VISTA-40 Installation and Setup  
Guide for detailed definitions of each zone type. Enter the zone type desired (or change it, if necessary).  
Available zone types are listed below.  
10 ZONE TYPE  
PERIMETER  
03  
Zone number 10 and Zone  
Type 03 entry shown  
00 = Assign for Unused Zones  
01 = Entry/Exit #1, Burglary  
02 = Entry/Exit #2, Burglary  
03 = Perimeter, Burglary  
04 = Interior Follower, Burglary  
05 = Trouble Day/Alarm Night  
06 = 24 Hr. Silent Alarm  
08 = 24 Hr. Auxiliary  
09 = Fire Without Verification  
10 = Interior Delay, Burglary  
20 = ArmSTAY†  
21 = Arm AWAY†  
22 = Disarm†  
These are special zone  
types used with 5800  
Series Wireless  
Pushbutton Units that  
result in arming the system  
in the STAY or AWAY  
mode, or disarming the  
system, depending on the  
selection made.  
23 = No Alarm Response  
(e.g., relay activation)  
07 = 24 Hr. Audible Alarm  
Press [] to continue.  
Enter the partition number (12) you are assigning this zone to.  
Press [] to continue.  
10 Partition  
1
Enter the report code. The report code consists of 2 hexadecimal digits, each in turn consisting of 2  
numerical digits. For example, for a report code of "3C," enter 03 for "3" and 12 for "C."  
(Refer to the System Communication section in the Installation and Setup Guide for more information about  
10 REPORT CODE  
1st 03 2nd 12  
3C  
report codes and reporting formats.)  
Press [] to continue.  
11 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROMPT  
EXPLANATION  
Enter the input device type as follows:  
00 = not used  
10 INPUT TYPE  
RF Xmitter  
3
01 = hardwired  
Input types 4 & 5 are  
valid for certain 5800  
Series transmitters only  
(e.g., 5801, 5802, 5802CP  
& 5803).  
03 = supervised RF transmitter (RF type)  
04 = unsupervised RF transmitter (UR type)  
05 = RF button-type transmitter (BR type)  
06 = serial number polling loop device (SL type)  
07 = DIP switch-type polling loop device  
08 = right loop of DIP switch type device  
Right loops refer to the use of the right loop on a 4190WH Zone Expander Module and/or 4278 PIR, which  
allow hardwired devices to be monitored by the polling loop.  
If you are programming hardwired or DIP switch polling loop devices, the summary display appears after  
completing this entry.  
Press [] to continue.  
For Serial Number entry and Loop Number entry, do one of the following:  
a. Transmit two open and close (or close and open) sequences. For a button-type transmitter, press and  
release the button, wait approximately 4 seconds, then press and release the button a second time.  
10 INPUT S/N:  
AXXX-XXXX  
L
1
OR  
b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the Alpha keypad.  
Then press the [] key, the cursor moves to the Lposition. You can edit the loop number, if necessary.  
When the loop number is acceptable, press [].  
OR  
c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several  
input loops).  
Press [] to accept.  
The cursor will then move to the Loop column (L) with the previously entered/transmitted serial number  
displayed.  
Enter the loop number (refer to 5800 Series Transmitters Loop Designations below).  
10 INPUT S/N:  
A022-4064  
L
1
To Delete an Existing Serial Number, enter 0 in the loop number field. The serial number will change to  
0s.  
If 0 was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the  
display.  
Press [] to accept.  
The system will then check for a duplicate serial/loop number combination.  
If a duplicate serial/loop number combination is found, the keypad will emit a single long beep, and display  
the serial number along with a ?for the loop number, allowing you to re-enter the correct loop number.  
If the serial/loop number combination is not a duplicate in the system, a display appears showing the serial  
number and loop number entry.  
10 INPUT S/N:  
A022-4064  
L
1
Press [] to continue.  
12 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5800 Series Transmitters Loop Designations  
LOOP 3  
LOOP 2  
(REED)  
LOOP 1  
(PRIMARY)  
LOOP 2  
LOOP 1  
LOOP 2  
(AUX. CENTER)  
LOOP 1  
(TERMINALS)  
LOOP  
1
LOOP 3  
LOOP 4  
(AUX. RIGHT)  
ALTERNATE  
POSITION  
FOR LOOP 2  
YOU MUST  
ENROLL THIS  
BUTTON  
5817  
ENROLL AS "RF"  
5816MN  
ENROLL AS "RF"  
5801  
5802MN  
ENROLL AS "UR" OR "RF"  
ENROLL AS "UR" OR "RF"  
LOOP 3  
LOOP 2  
(REED)  
YOU MUST  
ENROLL THIS  
BUTTON  
LOOP  
LOOP 1  
(TERMINALS)  
LOOP 2  
LOOP 1  
2
LOOP 4  
(REED)  
LOOP 2  
LOOP 1  
LOOP 3  
(TERMINALS)  
(INTERNAL  
SHOCK  
YOU MUST  
ENROLL THIS  
BUTTON  
SENSOR)  
LOOP 3  
(TERMINALS)  
LOOP 4  
5819S (WHS & BRS)  
ENROLL AS "RF"  
5819  
ENROLL AS "RF"  
LOOP 1  
LOOP 3  
5804  
ENROLL  
AS "BR"  
• •  
SET  
HOUSE  
CODE  
• •  
5827  
SET HOUSE CODE  
• •  
5827BD  
SET HOUSE CODE  
5804BD  
ENROLL AS "BR"  
LOOP  
1
5809  
ENROLL AS "RF"  
LOOP 2  
(REED)  
LOOP 1  
(MOTION)  
LOOP  
1
(Green)  
(Red)  
(Yellow)  
LOOP 1  
(TERMINALS)  
5808  
ENROLL AS "RF"  
5816  
ENROLL AS "RF"  
5850 (GBD)  
ENROLL AS "RF"  
5890  
ENROLL AS "RF"  
5800_trans_loop-V0  
Note: For information on any transmitter not shown above, refer to the instructions accompanying that transmitter for  
details regarding loop numbers, etc.  
The 5802MN, 5802MN2, 5804, 5804BD, 5814, 5816TEMP, 5819, 5819WHS & BRS, 5827BD,  
and 5850 transmitters are not intended for use in UL installations.  
U
L
PROMPT  
EXPLANATION  
Confirmation Option: This prompt only appears if you answered Yesat the first prompt. The system  
enters a confirmation mode so that the operation of the actual programmed input can be confirmed. Activate  
the loop input or button that corresponds to this zone. At any time during this step, you may press the [] key  
on the keypad to save the serial and loop number combination without confirming.  
XMIT TO CONFIRM  
PRESS TO SKIP  
If the serial number transmitted does not match the serial number entered, a display similar to the one  
at the left appears. If the loop number does not match, it is also displayed.  
Entd  
Rcvd  
A022-4063  
A022-4064  
1
If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary  
display does not appear), press the [#] key twice and then enter or transmit the correct serial number.  
If the serial number transmitted does match the serial number entered, the system beeps 3 times and a  
summary display appears, showing that zones programming. Note that an sindicates that a transmitters  
serial number has been enrolled.  
10 ZT P RC In  
03 3C RF 1s  
L
1
Press [] to accept the zone information.  
13 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROMPT  
EXPLANATION  
The system now returns to the ENTER ZONE NO.prompt for the next zone.  
When all zones have been programmed, enter 00 to quit.  
ENTER ZONE NO.  
00 = QUIT  
11  
After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in  
the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information  
(zone number, zone type, etc.) relevant to that device.  
When you have finished programming all zones, test each using the systems Test Mode. Do not use the  
Transmitter ID Sniffer Mode. The system checks only for transmission of one zone on a particular  
transmitter, NOT the zones assigned to each additional loop, and also does not verify polling loop type  
zones.  
Expert Mode Zone Programming  
Expert mode allows you to program zones using the minimum number of screens and keystrokes.  
Enter the Programming mode with [Installer Code] + [8] [0] [0]  
Before programming your zones, do the following:  
1. Program field 200: Number of Partitions.  
2. Enable your RF Receiver in Device Programming menu mode.  
To program your zones, press 93 to display the "ZONE PROG?" prompt. Enter 0 (NO) to each prompt until the EXPERT  
MODE?prompt appears.  
PROMPT  
EXPLANATION  
Press 1 to enter Expert mode.  
EXPERT MODE?  
1 = YES 0 = NO  
0
This prompt appears once upon entering Expert Mode.  
If you select Yes,Confirmation prompts will be displayed after the devices Serial and Loop numbers have  
been entered later.  
SET TO CONFIRM?  
0 = NO 1 = YES  
0
A summary display appears, showing zone 1s current programming or default values.  
Zn ZT P RC In  
L
01 03  
1
10 HW  
-
Enter the desired 2-digit zone number and press [].  
Note: If you want to exit the Expert mode, enter 00 + [].  
If an sappears after the loop number, it indicates that the transmitters serial number has been enrolled.  
Use the [D] key to enter and duplicate wireless keys (see Entering Wireless Keyslater)  
Zn ZT  
10 03  
P
RC In  
L
1
10 RF 1s  
Enter all zone information except for Loop number, or press [C] to copy the zone information on this screen  
from the last saved zone (including Loop).  
Zn ZT  
10 03  
P
RC In  
L
-
1
10 RF  
ZT = Zone Type  
P
= Partition  
RC = Report Code  
In = Input Device Type  
L
= Loop number to which the sensor is connected.  
NOTE: Pressing the [C] copies the zone information from the last saved zone, which includes the  
input type. Verify this information is correct for this zone.  
On this screen:  
Use the [A] key to move to the right.  
Use the [B] key to move to left and to back up to ZTfield.  
Press [] to accept the existing or newly entered zone information.  
14 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROMPT  
EXPLANATION  
If you entered RF, BR, UR or SL for the Input Type, this screen displays. Otherwise the summary screen for  
the next zone displays.  
Enter the 7-digit serial number, using one of the following methods:  
a. Transmit two open and close (or close and open) sequences. For a button-type transmitter, press and  
release the button, wait approximately 4 seconds, then press and release the button a second time.  
OR  
10 INPUT S/N:  
A XXX-XXXX  
L
-
b. Manually enter the 7-digit serial number printed on a label on the transmitter, using the alpha keypad.  
Then press the [] key, the cursor will move to the Lposition. You can edit the loop number, if  
necessary. When the loop number is acceptable, press [].  
OR  
c. Press key [C] to copy the last serial number enrolled (used when programming a transmitter with several  
input loops).  
Remember, you can use the [A] key to move to the right or the [B] key to move to the left.  
You can also use the [#] key to back up without saving.  
Press [] to accept the serial number and advance to the Lposition (if method aor cwas used), then  
enter the loop number.  
If necessary, press the [#] key to back up without saving, and re-enter or edit the serial number before  
pressing [] to save  
10 INPUT S/N:  
A022-4064  
L
1
The system checks for a duplicate. If a duplicate serial/loop number combination is found, the keypad will  
emit a single long beep, and display the serial number along with a ?for the loop number, allowing you to  
re-enter the correct loop number.  
To Delete an Existing Serial Number, enter 0 in the loop number field. The serial number will change to  
0s.  
If 0 was entered in error, simply re-enter the loop number or press [#], and the serial number will return to the  
display.  
10 INPUT S/N:  
A000-0000  
L
1
The prompt to confirm appears. This prompt only appears if you answered Yesat the SET TO  
CONFIRM?prompt.  
XMIT TO CONFIRM  
PRESS TO SKIP  
The system enters a confirmation mode so that the operation of the actual programmed input can be  
confirmed. Activate the loop input or button that corresponds to this zone. At any time during this step, you  
may press the [] key on the keypad to save the serial and loop number combination without confirming.  
If the serial number transmitted does not match the serial number entered, a display similar to the one  
at the left appears. If the loop number does not match, it also is displayed.  
Entd  
Rcvd  
A022-4063  
A022-4064  
1
L
If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary  
display for the next zone does not appear), press the [#] key twice and then enter or transmit the correct  
serial number.  
Activate the button on the wireless key again after re-entering the serial number.  
If the serial number transmitted matches the serial number entered, the system beeps 3 times and  
advances to the summary display for the next zone's programming.  
Zn  
11  
ZT  
00  
P
1
RC In  
10  
00 1  
After all the zones have been programmed, enter 00 for the zone number to quit.  
After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in  
the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information  
(zone number, zone type, etc.) relevant to that device.  
Entering Wireless Keys  
If you pressed the D key previously to enter defaults for 5804 and/or 5804BD wireless keys, the following screens appear:  
PROMPT  
EXPLANATION  
Enter template number (16).  
FROM TEMPLATE  
13 = 5804 templates; 46 = 5804BD templates. See the defaults provided for each template in the chart  
that follows these procedures.  
16  
1
Select from templates. Press [] to display template (template 1 shown selected).  
Note: If necessary, press [#] to back up and re-enter template number.  
Press [#] if you want to return to zone attributes screen.  
When you press [], the selected template is displayed.  
Top line of display represents loop numbers; bottom line represents zone type.  
Press [] to accept template.  
L
01 02 03 04  
ZT 23 22 21 23  
1
15 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROMPT  
EXPLANATION  
Enter partition number for wireless key.  
Press [] to continue.  
PARTITION  
1
The system searches for the highest available, consecutive 4-zone group (the four zones required for the  
5804 and 5804BD), and displays the lowest zone number of the group.  
If you want to start at a different zone number, enter the zone desired and press [].  
If that zone number is displayed, the system has the required number of consecutive zones available,  
beginning with the zone you entered. If not, the system again displays a suggested zone that can be used.  
If the required number of consecutive zones is not available at all, the system will display 00.”  
Press [] to accept.  
ENTER ZONE NO  
00 = QUIT  
24  
L
Example of zone number  
suggested by the system.  
This indicates that zones  
24, 25, 26, and 27 are  
available.  
To enter the serial number:  
Press and release a button on the wireless key.  
OR  
24 INPUT S/N  
AXXX-XXXX  
L
1
Manually enter the 7-digit serial number printed on the devices label.  
Press [] to accept serial number. The system checks for a duplicate.  
If a duplicate exists, a long error beep will sound and the serial number reverts back to all Xs allowing  
you to re-enter the serial number.  
Use the [A] key to move forward within the screen, and the [B] key to back up.  
If you entered YES previously at the SET TO CONFIRM prompt (see first prompt following entry into the  
Expert Programming Mode), the display on the left appears.  
To confirm, activate the button on the wireless key that corresponds to this zone.  
XMIT TO CONFIRM  
PRESS TO SKIP  
If the serial number transmitted does not match the serial number entered, a display similar to the one  
at the left appears.  
If so, activate the loop input or button on the transmitter once again. If a match is not obtained (i.e., summary  
display does not appear), press the [#] key and then enter the correct serial number.  
Entd  
Rcvd  
A022-4063  
A022-4064  
Activate the button on the wireless key again after re-entering the serial number.  
If the serial number transmitted matches the serial number entered, the system will beep 3 times and  
revert to the "Start Zone No." prompt and will show the lowest numbered zone of the next available 4-zone  
group (4 consecutive zones) that is available for programming.  
ENTER ZONE NO  
00 = QUIT  
28  
After all the wireless keys have been entered, enter 00 for the zone number to quit.  
After you have enrolled each wireless device, remove ONE of the serial number labels from that device and affix it in  
the appropriate column on the worksheets provided later in this Programming Guide; then enter the other information  
(zone number, zone type, etc.) relevant to that device.  
Wireless Key Default Templates  
5804  
5804BD  
Template 1  
Loop Function  
Zone Type Template 4  
Loop  
Function  
Zone Type  
1
2
3
4
No Response  
23  
1
No Response  
No Response  
Arm AWAY  
Disarming  
23  
Disarming  
22  
2
23  
Arm AWAY  
No Response  
21  
3
21  
23  
4
22  
Template 2  
Template 3  
Loop Function  
Zone Type Template 5  
Loop  
Function  
Zone Type  
1
2
3
4
No Response  
23  
1
No Response  
Arm STAY  
Arm AWAY  
Disarming  
23  
Disarming  
Arm AWAY  
Arm STAY  
22  
2
20  
21  
3
21  
20  
4
22  
Loop Function  
Zone Type Template 6  
Loop  
Function  
Zone Type  
1
2
3
4
24-Hour Panic  
07  
22  
21  
20  
1
2
3
4
24-Hour Panic  
Arm STAY  
Arm AWAY  
Disarming  
07  
20  
21  
22  
Disarming  
Arm AWAY  
Arm STAY  
16 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alpha Descriptors Programming  
You can program a user-friendly English language description/location for all protection zones, relays, keypad panics, polling  
loop short, and RF receiver supervision troubles.  
Each description can be composed of a combination of words (up to 3) that are selected from a vocabulary of 244 words  
stored in memory, and any word can have an "s" or " s " added to it. In addition, up to 20 installer-defined words can be added  
to those already in memory. Thus, when an alarm or trouble occurs in a zone, an appropriate description for the location of  
that zone will be displayed at the keypad.  
NOTE: Due to the use of 2-digit zone numbers, the first word of the descriptor is limited to 7 characters if you want it to fit on  
the top line of the display.  
A custom installers message can be programmed for each partition, which is displayed when the system is "Ready" (e.g., THE  
PETERSONS).  
1. To program alpha descriptors, enter Programming mode, then press [#]93 to display "ZONE PROG?"  
2. Press 0 (NO) twice to display "ALPHA PROG?".  
3. Press 1 to enter Alpha Programming.  
There are 5 submenu selections that will be displayed one at a time.  
Press 1 to select the mode desired. Press 0 to display the next mode available. The alpha menu selections are:  
ZONE DESCRIP?  
DEFAULT SCREEN?  
CUSTOM WORD?  
PART DESCRIP?  
EXIT EDIT MODE?  
For entering zone descriptors.  
For creating custom message; displayed when system is ready.  
For creating custom words for use in descriptors.  
For creating 4-character partition names.  
Press 1 to exit back to #93 Menu Mode.  
4. Refer to the sections that follow for procedures for adding alpha descriptors.  
Zone Descriptors  
1. Select ZONE DESCRIPTOR mode.  
The keypad keys perform the following functions:  
[3] Scrolls both alphabet and actual words in ascending alphabetical order.  
[1] Scrolls both alphabet and actual words in descending alphabetical order.  
[2] Adds or removes an "s" or " 's " to a vocabulary word.  
[6] Switches between alphabet and actual word list; used to accept entries.  
[8] Saves the zone description in the system's memory.  
[#] [#] plus zone number displays the description for that zone.  
2. Enter the zone number to which you want to assign a descriptor.  
For example, key [] 01 to begin entering the description for Zone 1, (key [] 02 for Zone 2, [] 03 for Zone 3, etc.). The  
following is displayed: ZN 01 A.  
Note that the first letter of the alphabet appears after the zone number, and that the zone number is automatically  
included with the description.  
3. Enter the descriptor for that zone.  
Use one of two methods as follows:  
(Assume, for example, that the desired description for Zone 1 is BACK DOOR.)  
a) Press [#] followed by the 3-digit number of the first word from the fixed dictionary shown later in this section (e.g.,  
[0][1][3] for BACK).  
Press 6 in order to accept the word and proceed, or press 8 to store the complete descriptor and exit;  
or  
b) Select the first letter of the desired description (note that "A" is already displayed). Use the 3 key to advance through  
the alphabet and the 1 key to go backward.  
Press 3 key repeatedly until "B" appears (press 1 to go backwards if you happen to pass it), then press 6 to display  
the first available word beginning with B.  
Press 3 repeatedly to advance through the available words until the word BACKis displayed.  
To add an "s" or " 's" if you need to, press 2. The first depression adds an "s," the second depression adds  
an " 's, " the third depression displays no character (erases the " 's"), the fourth depression adds an "s," etc.  
17 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. Accept the word.  
To accept the word, press 6, which switches back to the alphabet list for the next word, or press 8 to store the complete  
descriptor and then exit.  
5. Select the next word.  
For selection of the next word (DOOR), repeat step 3a (word #057) or 3b, but selecting the word "DOOR.”  
To accept the word, press 6, which again switches back to alphabet list.  
6. Store the descriptor.  
When all desired words have been entered, press 8 to store the description in memory.  
To review the zone descriptors, key [#] plus zone number (e.g., #01).  
To edit zone descriptors, key [] plus zone number (e.g., 01)  
7. Exit Zone Description Mode: enter 00.  
Default Screen (Custom Message Display)  
Normally, when the system is in the disarmed state, the following display is present on the keypad.  
****DISARMED****  
READY TO ARM  
Part or all of the above message can be modified to create a custom installer message for each partition. For example,  
****DISARMED****on the first line or READY TO ARMon the second line could be replaced by the installation company  
name or phone number for service.  
Note: There are only 16 character spaces on each of the two lines.  
To create a custom display message, proceed as follows:  
1. Select Default Screen mode.  
The keypad asks for the partition number for this message.  
Enter the partition number. Press [] to accept entry.  
The following display appears:  
****DISARMED****  
READY TO ARM  
A cursor is present at the extreme left of the first line (over the first "star"). Press 6 to move the cursor to the right and 4 to  
move the cursor to the left. Press 7 to insert spaces or erase existing characters.  
2. Create the message.  
For example, to replace READY TO ARMwith the message SERVICE 424-0177,proceed as follows:  
Press 6 to move the cursor to the right, and continue until the cursor is positioned over the first location on the second  
line.  
Press 3 to advance through the alphabet to the first desired character (in this case, "S"). Press 1 to go backward, when  
necessary. When the desired character is reached, press 6.  
The cursor then moves to the next position, ready for entry of the next character (in this example, "E"). When the cursor  
reaches a position over an existing character, press 3 or 1 to advance or back up from that character in the alphabet.  
Proceed in this manner until all characters in the message have been entered.  
3. Save the message.  
Store the new display message in memory by pressing 8.  
4. The system asks for a new partition number.  
Enter 0 to quit or 1-2 for a new partition number.  
Custom Words  
Up to 20 installer-defined words can be added to the built-in vocabulary. Each of the 20 "words" can actually consist of several  
words, but bear in mind that a maximum of 10 characters can be used for each word string.  
1. Select CUSTOM WORD Mode.  
The keys perform the following functions:  
[3] Advances through alphabet in ascending order.  
[1] Advances through alphabet in descending order.  
[6] Selects desired letter; moves the cursor 1 space to the right.  
[4] Moves the cursor one space to the left.  
[7] Inserts a space at the cursor location, erasing any character at that location.  
[8] Saves the new word in the system's memory.  
[] Returns to Description Entry Mode.  
18 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Enter the custom word number (01-20) you want to create.  
For example, if you are creating the first word (or word string), enter 01; when creating the second word, enter 02, and so  
on. A cursor now appears at the beginning of the second line.  
3. Type the word using one of two methods as follows:  
a) Press [#], followed by the 2-digit entry for the first letter you would like to display (e.g., 65 for "A").  
When the desired character appears, press 6 to select it. The cursor will then move to the right, in position for the  
next character. Press [#] plus the 2-digit entry for the next letter of the word.  
or  
b) Press 3 to advance through the list of symbols, numbers, and letters.  
Press 1 to move back through the list.  
When you have reached the desired character, press 6 to select it. The cursor then moves to the right, in position for  
the next character.  
4. Repeat step 3 to create the desired custom word (or words).  
Press 4 to move the cursor to the left if necessary.  
Press 7 to enter a blank (or to erase an existing character).  
Each word or word string cannot exceed 10 characters.  
5. Save the word by pressing 8.  
This returns you to the CUSTOM WORD?display. The custom word (or string of words) is automatically added to the  
built-in vocabulary at the end of the group of words beginning with the same letter.  
Custom words are retrieved as word numbers 250 to 269 for words 1 to 20, respectively, when using method 3a to enter  
alpha descriptors.  
When using method 3b to enter alpha descriptors, each word appears at the end of the group of words that begin with the  
same letter as it does.  
6. Repeat steps 2 through 6 to create up to a maximum of 20 custom words (or word strings).  
7. Exit Custom Word Mode by entering 00 at the CUSTOM WORDprompt.  
Partition Descriptors  
1. Select "Part DESCRIPT." Mode.  
The system asks for the partition number desired. Enter the number as a single-key entry 1-2.  
2. Follow the same procedure as for custom words.  
Note: The partition descriptors are limited to 4 characters (e.g., WHSE for warehouse).  
19 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Alpha Descriptor Vocabulary  
(For entering alpha descriptors. To select a word, press [#] followed by the words 3-digit number.)  
NOTE: This vocabulary is not to be used for relay voice descriptors. See the Relay Voice Descriptors section when  
programming relay voice descriptors.  
000 (Word Space)  
001 AIR  
002 ALARM  
003 ALCOVE  
004 ALLEY  
005 AMBUSH  
006 AREA  
007 APARTMENT  
008 ART  
052 DETECTOR  
053 DINING  
054 DISCRIMINATOR  
055 DISPLAY  
056 DOCK  
057 DOOR  
058 DORMER  
059 DOWN  
060 DOWNSTAIRS  
061 DRAWER  
062 DRIVEWAY  
063 DRUG  
102 INTERIOR  
103 INTRUSION  
151 POLICE  
152 POOL  
153 POWER  
202 TRANSMITTER  
203 TRAP  
104 JEWELRY  
105 KITCHEN  
204 ULTRA  
205 UP  
154 QUAD  
206 UPPER  
207 UPSTAIRS  
208 UTILITY  
209 VALVE  
210 VAULT  
211 VIBRATION  
212 VOLTAGE  
106 LAUNDRY  
107 LEFT  
108 LEVEL  
109 LIBRARY  
110 LIGHT  
111 LINE  
112 LIQUOR  
113 LIVING  
114 LOADING  
115 LOCK  
155 RADIO  
156 REAR  
157 RECREATION  
158 REFRIG  
159 REFRIGERATION  
160 RF  
161 RIGHT  
162 ROOM  
163 ROOF  
009 ATTIC  
010 AUDIO  
011 AUXILIARY  
064 DUCT  
012 BABY  
013 BACK  
014 BAR  
015 BARN  
016 BASEMENT  
017 BATHROOM  
018 BED  
019 BEDROOM  
020 BELL  
021 BLOWER  
022 BOILER  
023 BOTTOM  
024 BOX  
025 BREAK  
026 BUILDING  
027 BURNER  
213 WALL  
214 WAREHOUSE  
215 WASH  
216 WEST  
217 WINDOW  
218 WINE  
219 WING  
220 WIRELESS  
221 WORK  
065 EAST  
066 ELECTRIC  
067 EMERGENCY  
068 ENTRY  
069 EQUIPMENT  
070 EXECUTIVE  
071 EXIT  
116 LOOP  
117 LOW  
118 LOWER  
164 SAFE  
165 SCREEN  
166 SENSOR  
167 SERVICE  
168 SHED  
169 SHOCK  
170 SHOP  
171 SHORT  
172 SHOW  
173 SIDE  
174 SKYLIGHT  
175 SLIDING  
176 SMOKE  
177 SONIC  
119 MACHINE  
120 MAGNETIC  
121 MAIDS  
122 MAIN  
123 MASTER  
072 EXTERIOR  
073 FACTORY  
074 FAILURE  
075 FAMILY  
076 FATHERS  
077 FENCE  
078 FILE  
079 FIRE  
080 FLOOR  
081 FLOW  
222 XMITTER  
223 YARD  
124 MAT  
125 MEDICAL  
126 MEDICINE  
127 MICROWAVE  
128 MONEY  
129 MONITOR  
130 MOTHERS  
131 MOTION  
132 MOTOR  
133 MUD  
224 ZONE (No.)  
225 ZONE  
028 CABINET  
029 CALL  
030 CAMERA  
031 CAR  
032 CASE  
033 CASH  
178 SONS  
226  
227  
0
1
179 SOUTH  
180 SPRINKLER  
181 STAMP  
182 STATION  
183 STEREO  
184 STORE  
185 STORAGE  
186 STORY  
187 STRESS  
188 STRIKE  
189 SUMP  
082 FOIL  
228 1ST  
229  
230 2ND  
231  
232 3RD  
233  
234 4TH  
235  
236 5TH  
237  
238 6TH  
239  
240 7TH  
241  
242 8TH  
243  
083 FOYER  
084 FREEZER  
085 FRONT  
086 FUR  
2
3
034 CCTV  
134 NORTH  
135 NURSERY  
035 CEILING  
036 CELLAR  
037 CENTRAL  
038 CIRCUIT  
039 CLIP  
040 CLOSED  
041 COIN  
087 FURNACE  
4
088 GALLERY  
089 GARAGE  
090 GAS  
136 OFFICE  
137 OIL  
138 OPEN  
139 OPENING  
140 OUTSIDE  
141 OVERFLOW  
142 OVERHEAD  
5
6
091 GATE  
190 SUPERVISED  
191 SUPERVISION  
192 SWIMMING  
193 SWITCH  
092 GLASS  
093 GUEST  
094 GUN  
7
042 COLD  
043 COATROOM  
044 COLLECTION  
045 COMBUSTION  
046 COMPUTER  
047 CONTACT  
8
095 HALL  
096 HEAT  
097 HIGH  
098 HOLDUP  
099 HOUSE  
143 PAINTING  
144 PANIC  
145 PASSIVE  
146 PATIO  
147 PERIMETER  
148 PHONE  
149 PHOTO  
150 POINT  
194 TAMPER  
195 TAPE  
196 TELCO  
197 TELEPHONE  
198 TELLER  
199 TEMPERATURE  
200 THERMOSTAT  
201 TOOL  
9
244 9TH  
250 Custom Word 1  
to  
048 DAUGHTERS  
049 DELAYED  
050 DEN  
269 Custom Word 20  
100 INFRARED  
101 INSIDE  
051 DESK  
CHARACTER (ASCII) CHART  
(For Adding Custom Words)  
32  
33  
34  
35  
36  
37  
38  
39  
40  
41  
(space)  
!
"
#
$
%
&
(
)
42  
43  
44  
45  
46  
47  
48  
49  
50  
51  
*
+
,
-
.
52  
53  
54  
55  
56  
57  
58  
59  
60  
61  
4
5
6
7
8
9
:
;
<
=
62  
63  
64  
65  
66  
67  
68  
69  
70  
71  
>
?
72  
73  
74  
75  
76  
77  
78  
79  
80  
81  
H
I
J
K
L
M
N
O
P
Q
82  
83  
84  
85  
86  
87  
88  
89  
90  
R
S
T
U
V
W
X
Y
Z
@
A
B
C
D
E
F
/
0
1
2
3
G
Notes: This factory-provided vocabulary of words is subject to change.  
Bulleted words in bold face type are those that are also available for use by the 4285/4286 VIP Module. If you are  
using a VIP Module, and words other than these are selected for alpha descriptors, the Voice Module will not provide  
annunciation of those words.  
20 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Device Programming  
This menu is used to program keypads, receivers, and relay modules, etc.  
Device Address 00 is always set as an alpha keypad assigned to Partition 1 with no sounder suppression  
options, and these settings cannot be changed.  
From Data Field Programming mode, press [#]93 to display "ZONE PROG?" Press 0 repeatedly to display "DEVICE PROG?"  
PROMPT  
EXPLANATION  
Press 1 to enter Device Programming.  
DEVICE PROG?  
1=YES 0=NO  
0
The device address identifies the device to the control. Enter the 2-digit device address number to match  
the devices physical address setting (01-15).  
NOTE: If using the 4285/4286 Voice Module, it must be used at Device Address 04.  
DEVICE ADDRESS  
01-15, 00=QUIT  
01  
Select the type of addressable device as follows:  
DEVICE TYPE  
0 = device not used  
3 = RF receiver (5881)  
0
1 = alpha keypad (6139/6160)  
2 = fixed keypad (6137/6150)  
Press [] to accept entry.  
4 = output relay module (4204)  
5 = voice (VIP) Module (4285/4286)  
Alpha Keypad  
PROMPT  
EXPLANATION  
If you selected device type 1 (alpha keypad) or 2 (fixed keypad), this prompt appears. Enter the addressable  
devices default partition number (1 to maximum number of partitions programmed for system in field 2*00).  
This is the primary partition for the device.  
01 CONSOLE PART.  
1
Press [] to accept entry.  
Keypads can be individually programmed to suppress arm/disarm beeps, entry/exit beeps and chime mode  
beeps. This helps prevent unwanted sounds from disturbing users in other areas of the premises.  
01 SOUND OPTION  
00  
Enter a number 00-03 for the keypad sounding suppression options desired for the keypad as follows:  
00 = no suppression  
01 = suppress arm/disarm & entry/exit beeps  
02 = suppress chime mode beeps only  
03 = suppress arm/disarm, entry/exit and chime mode beeps  
Press [] to accept entry.  
RF Expander  
PROMPT  
EXPLANATION  
If you selected device type 3 (RF receiver), this prompt appears. Enter the 2-digit House ID (00-31). This is  
required if you are using a wireless keypad (5827/5827BD).  
01 RF EXPANDER  
HOUSE ID  
00  
Press [] to accept entry.  
VIP Module  
PROMPT  
EXPLANATION  
If you selected device type 5 (VIP Module), this prompt appears. Enter the partition number 1-2 in which the  
module is located.  
Press [] to accept entry.  
01 MODULE PART.  
1
Press 00 + [] to exit Menu mode.  
Press 99 to exit Program mode.  
21 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Relay Programming  
The system supports up to 8 relay outputs. Relays can be used to perform many different functions and actions. Each relay  
must be programmed to begin one of three types of ACTIONS at a designated START event, and end that ACTION at a  
designated STOP event. The options and prompts used to start and stop these devices are described below  
The letter(s) in parentheses after each function described below, such as (A) after ACTION, are those that appear in the  
various summary displays of programmed data during programming.  
ACTION (A)  
The "ACTION" of the device is how the device will respond when it is activated by the "START"  
programming. You may want the device to activate momentarily, to pulse on and off continuously, or to  
remain activated until some other event occurs to stop it. There are five different action choices:  
ACTIVATE for 2 SECONDS and then reset.  
ACTIVATE and REMAIN ACTIVATED until stopped by some other event.  
PULSE ON and OFF until stopped by some other event.  
NO RESPONSE when the device is not used.  
START (STT)  
The "START" programming determines when and under what conditions the device is activated. The  
following START options are available:  
1) EVENT (EV) is the condition (alarm, fault, trouble) that must occur to a zone or group of zones (zone  
list) in order to activate the device. These conditions apply only when a zone list is used. The different  
choices for "EVENT" are listed below and in Programming Relayslater in this section.  
ALARM  
Action begins upon any alarm in an assigned zone in the zone list.  
Action begins upon any opening of an assigned zone in the zone list.  
Action begins upon any trouble condition in an assigned zone in the zone list.  
Action is not dependent upon one of the above events.  
FAULT  
TROUBLE  
NOT USED  
ZONE LIST (ZL) is a group of zones to which the EVENTapplies in order to activate a particular  
device. Note that there are a total of 4 zone lists that can be programmed; when the selected EVENT  
(alarm, fault or trouble) occurs in any zone in the selected StartZONE LIST (1-4), activation of the  
selected device will START.  
3) ZONE TYPE/SYSTEM OPERATION (ZT). If all zones to be used to start the device have the same  
response type, and there are no other zones of this type that are not to activate this device, then  
ZONE TYPEmay be used instead of a "ZONE LIST" and "EVENTto activate the device.  
If a system operation, such as DISARMINGor ANY FIRE ALARM,is to activate the device, enter  
the appropriate choice under the ZONE TYPEoption.  
The “ZONE TYPE/SYSTEM OPERATION” option functions independently of the “EVENT/ZONE  
LIST” combination.  
If a specific "ZONE TYPE" is chosen, any zone of that response type going into alarm, trouble, or fault  
will cause the device to activate as selected in "ACTION.If the same ZONE TYPEis also chosen for  
the STOP programming, any zone of that type that restores will de-activate the device.  
If a "SYSTEM OPERATION" is chosen, that operation will cause the device to activate as selected in  
"ACTION.The different choices for "ZONE TYPE" and "SYSTEM OPERATION" are listed in  
Programming Relayslater in this section, and on the Programming Form.  
4) PARTITION NO. (P). The device's "Start" ZONE TYPE/SYSTEM OPERATION may be limited to an  
occurrence on one partition (1-2), or any partition (0).  
STOP (STP):  
The "STOP" programming determines when and under what conditions the device is de-activated. The  
following options are available:  
1). RESTORE ZONE LIST (ZL). If a "ZONE LIST" is used as the Stopevent, the device de-activates  
when all the zones in that list restore from a previous fault, trouble, or alarm condition. This occurs  
regardless of what is programmed to "START" the device; therefore, a "RESTORE ZONE LIST" is  
normally only used when a "ZONE LIST" is used to start the device.  
2). ZONE TYPE/SYSTEM OPERATION (ZT). Instead of using a "RESTORE ZONE LIST," you can select  
a specific zone (response) type or system operation action to de-activate the device.  
If you choose a specific "ZONE TYPE," any zone of that response type that restores from a previous  
alarm, trouble, or fault condition will cause the device to de-activate.  
If you choose a "SYSTEM OPERATION," that operation causes the device to de-activate. The  
different choices for "ZONE TYPE" and "SYSTEM OPERATION" are listed in Programming Relays”  
later in this section, and in the Programming Form.  
3) PARTITION NO. (P). The device's "Stop" Zone Type/System Operation may be limited to an  
occurrence on one partition (1-2), or on any partition (0).  
The ZONE TYPE/SYSTEM OPERATIONoption functions independently of the  
RESTORE/ZONE LISTcombination.  
22 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Relay Output Devices Programming  
From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt. Press [0] (NO) to each menu option  
until the "RELAY PROG?" prompt appears. Press [1] (YES).  
While in this mode, press [] to advance to next screen. Press [#] to back up to the previous screen.  
PROMPT  
EXPLANATION  
Enter the relay (output device) identification number 01-08. This is a reference number only, used for  
identification purposes. The actual module address and relay number on the module are programmed in the  
last two prompts.  
ENTER RELAY #  
(00=QUIT)  
01  
Press [] to continue.  
Press [] to continue.  
02 A EV ZL P  
STT 0 0 00  
0
The keypad displays a summary STOP screen.  
Press [] to continue.  
02  
A
0
ZL ZT  
00 00  
P
STOP  
0
The Relay Action is the way in which the relay will respond when activated by the "start" event. Enter the  
desired action for this relay as follows:  
02 RELAY ACTION  
NO RESPONSE  
0
0
0=not used; 1=close for 2 secs.; 2=stay closed; 3=pulse on/off  
A relay may be activated by an Event/Zone List combination, and/or by a Zone Type/System Operation. For  
an Event/Zone List combination, enter the event code as follows:  
02 START EVENT  
NOT USED  
0=not used; 1=alarm; 2=fault; 3=trouble  
If you are not using a Zone List to activate the relay, enter 0.  
Press [] to continue.  
A zone list is a set of zones that can be used to initiate the start or stop relay action. If a zone list is being  
used to start this relay action, enter the zone list number, 1-4. If a zone list is not being used, enter 0.  
Press [] to continue.  
02 START: ZN LIST  
0
A Zone Type/System Operation can be used instead of or in addition to an Event/Zone List combination or  
a specific zone to start the relay action. If a Zone Type/System Operation is being used, enter the 2-digit  
code as listed in the table that follows.  
02 START: ZN TYPE  
NO RESPONSE  
00  
Press [] to continue.  
Choices for Start/Stop Zone Types and System Operations:  
00 = No Response (Not Used)  
01 = Entry/Exit #1  
02 = Entry/exit #2  
03 = Perimeter  
04 = Interior Follower  
05 = Trouble Day/Alarm Night  
06 = 24-Hr. Silent  
23 = No Alarm Response  
31 = End of Exit Time  
32 = Start of Entry Time  
33 = Any Burglary Alarm  
34 = Code + [#] + 71 Key Entry  
35 = Code + [#] + 72 Key Entry  
36 = At Bell Timeout **  
37 = 2 Times Bell Timeout **  
38 = Chime  
39 = Fire Alarm  
40 = Bypassing  
31 = End of Exit Time  
41 = AC Power Fail  
42 = System Battery Low  
43 = Communication failure  
44 = RF Low Battery  
45 = Polling Loop Failure  
51 = RF Receiver Failure  
52 = Kissoff  
54 = Fire Zone Reset  
55 = Disarm + 1 Minute  
56 = XX Minutes (enter XX in field 1*74) *  
57 = YY Seconds (enter YY in field 1*75) *  
58 = Duress  
60 = Audio Alarm Verification (must be  
selected for both START and STOP  
operation)  
07 = 24-Hr. Audible  
08 = 24-Hr. Auxiliary  
09 = Fire Alarm or Trouble  
10 = Interior w/Delay  
20 = Arming-STAY  
21 = Arming-AWAY  
22 = Disarming (Code + Off)  
Stop condition only  
*
** Or at disarming, whichever occurs earlier  
If you are using options 56 and/or 57 (usually as the STOP Zone Type), you must program data fields 1*74  
and 1*75 for the respective relay timeouts for minutes and seconds.  
23 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROMPT  
EXPLANATION  
If the starting event will be limited to occurring on a specific partition, enter the partition number (1-2) in  
which the start event will occur. Enter 0 for any partition.  
Press [] to continue.  
02 START: PARTN  
ANY PARTITION  
0
Do not use a zone programmed with an RF Button (Input Type BR) to STOP a relay. The system will not de-  
activate the relay.  
PROMPT  
EXPLANATION  
If a zone list is being used to stop this relay action, enter the zone list number, 1-4. The restore of a zone  
on the zone list stops the relay. If a zone list is not being used, enter 0.  
Press [] to continue.  
02 STOP: ZN LIST  
00  
If a Zone Type/System Operation is being used to stop the relay action, enter the 2-digit code listed in the  
Choices for Start/Stop System Operation chart.  
Press [] to continue.  
02 STOP: ZN TYPE  
NO RESPONSE  
00  
0
This is the partition to which the stop condition will be limited. Enter 0 for any partition. Enter 1-2 for specific  
partition number.  
Press [] to continue.  
02 STOP: PARTN  
ANY PARTITION  
The system may have some devices that are not intended to be under end user control, such as relays  
activating fire doors or machinery. Enter 1 if the end user will be restricted from accessing this relay.  
Press [] to continue.  
02 RESTRICTION  
1=YES 0=NO  
0
Enter 1 for (ECP) relay modules (4204). Enter 2 for X-10 devices.  
Press [] to continue.  
02 RELAY TYPE  
V-PLEX  
0
If you selected 1 (4204), enter the actual modules address (01-15) as set by its DIP switches. Up to 2  
modules can be installed in a system.  
Press [] to continue.  
02 ECP ADDRESS  
00  
For 4204 Relay Outputs, enter the specific relay number on that module (1-4).  
Press [] to continue.  
02 MODULE RELAY#  
0
The keypad will display the Start and Stop summary screens again.  
Press [] to continue.  
If you selected 2 for X-10 devices, enter the numerical equivalent of the House Code of the device, as  
follows:  
02 HOUSE CODE  
A
00  
A=00  
B=01  
C=02  
D=03  
E=04  
F=05  
G=06  
H=07  
I=08  
J=09  
K=10  
L=11  
M=12  
N=13  
O=14  
P=15  
Enter the numerical unit code of the X-10 device (00-15).  
Press [] to continue.  
02 UNIT CODE  
00  
The keypad displays the Start and Stop summary screens again.  
Press [] to continue.  
When all relays have been programmed, enter 00 at the "ENTER RELAY NO." prompt.  
If you are defining a zone list, continue to the next section. If not, enter 00 + [] at the next two prompts. You will then be  
asked "Quit Menu Mode?" Enter 1 for "Yes," 0 for "No." Then enter []99 to exit programming completely.  
Zone List Programming  
After all relays have been programmed, upon entering 00 at the "ENTER RELAY NO." prompt, you are asked to enter a zone  
list. If a zone list number was used to start or stop a relay, you must define the zones belonging to that list as follows:  
PROMPT  
EXPLANATION  
Enter the zone list number 01-04. Enter 00 to quit.  
ENTER Zn LIST ?  
00=QUIT  
00  
24 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROMPT  
EXPLANATION  
Using 2-digit entries, enter each zone to be included in this zone list. Press [] after you enter each zone  
number.  
01 ADD ZONE #  
00=QUIT  
00  
When you have entered all zones, enter 00.  
Press [] to continue.  
Enter 0 to save this zone list. Enter 1 to delete it.  
01 Del Zn LIST ?  
1=YES 0=NO  
0
0
Enter 1 to delete one or more zones in that zone list. Enter 0 if no changes are necessary. If you enter 1,  
the following screen appears; otherwise, the "Enter Zone LIST" prompt reappears.  
01 DEL ZONES ?  
1=YES 0=NO  
Enter each zone number to be deleted from the zone list, pressing [] after each number.  
01 Zn to DELETE ?  
00=QUIT  
00  
00  
This display appears if you pressed 00 at the Enter Zone LISTprompt. Enter the zone list number that you  
wish to view.  
Press [] to continue.  
VIEW Zn LIST ?  
00=QUIT  
Press [] to scroll through all zones in that list. Enter 00 +[] to quit.  
Press 1 to exit Menu Mode.  
01 ASSIGNED ZONE  
00=QUIT  
00  
Press []99 to exit Program Mode.  
Relay Voice Descriptors  
If you are using the 4285/4286 VIP Module, you can program voice descriptors for each relay output. The descriptors are  
announced by the voice module when you access the relays via the # 70 Relay Access Mode over the telephone.  
Each voice descriptor can consist of up to 3 words selected from the Relay Voice Descriptors and Custom Word Substitutes  
Vocabulary list (later in this section).  
The index numbers from this vocabulary list are to be used for relay voice descriptors only. For normal  
system voice annunciation (e.g., alarms, troubles, status), use the highlighted words in the alpha vocabulary  
list in the Alpha Programming part of this guide.  
To enter relay voice descriptors, do the following:  
1. From Data Field Programming mode, press #93 to display the "ZONE PROG?" prompt.  
2. Press 0 (NO) to each menu option until the "RLY VOICE DESCR?" prompt is displayed. Follow the instructions below.  
While in this mode, press [] to advance to next screen. Press [#] to back up to previous screen.  
PROMPT  
EXPLANATION  
Press 1 to program voice descriptors for relays.  
RLY VOICE DESCR?  
1=YES 0=NO  
0
Enter the 2-digit relay number (01-08) for the relay desired, or enter 00 to quit Relay Voice Descriptor  
Programming Mode.  
Press []  
ENTER RELAY NO.  
00=QUIT  
01  
From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index  
number for the first word of the relay descriptor phrase.  
Press [] to accept entry.  
01 ENTER DESC d1  
01 ENTER DESC d2  
01 ENTER DESC d3  
From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index  
number for the second word of the relay descriptor phrase. If second word is not desired, press 000.  
Press [] to accept entry.  
From the Relay Voice Descriptors and Custom Word Substitutes Vocabulary list, enter the 3-digit index  
number for the third word of the relay descriptor phrase. If third word is not desired, press 000.  
Press [] to accept entry. The ENTER RELAY NO.prompt appears. Enter the next relay number to be  
programmed. When you have programmed all relay devices, enter 00 to quit.  
Enter []99 to exit Program Mode.  
25 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Relay Voice Descriptors and Custom Word Substitutes Vocabulary  
Word  
Index Word  
Index  
Daughters................208  
Den ..........................052  
Detector....................128  
Device......................060  
Dim...........................163  
Dining.......................031  
Door .........................016  
Down........................008  
Downstairs ...............184  
Driveway ..................130  
Duct..........................131  
Word  
Index  
Word  
Index  
Word  
Index  
Air ............................ 116  
Alarm ....................... 255  
And .......................... 067  
Apartment ................ 117  
Appliances ............... 161  
Area ......................... 118  
Attic.......................... 119  
Front.........................087  
No.............................165  
North.........................146  
Not............................012  
Side .........................153  
Six ...........................075  
Sixth.........................219  
Smoke .....................024  
Sons........................223  
South.......................155  
Stairs .......................006  
Station .....................156  
Storage....................157  
Sun..........................154  
System.....................062  
Garage .....................023  
Gas...........................138  
Glass........................139  
Off ............................011  
Office........................147  
On ............................058  
One...........................070  
Open.........................148  
Outside.....................210  
Hall...........................050  
Heat..........................010  
Baby......................... 120  
Back......................... 121  
Bar ........................... 122  
Basement................. 021  
Bathroom ................. 051  
Battery...................... 053  
Bed .......................... 092  
Bedroom .................. 015  
Blower...................... 123  
Boiler........................ 124  
Bright ....................... 162  
Building.................... 125  
Burglary.................... 039  
Inside........................209  
Kitchen .....................022  
Panic ........................013  
Partition ....................090  
Patio.........................149  
Phone.......................061  
Power .......................063  
Pump........................166  
East..........................132  
Eight.........................077  
Eighth.......................221  
Equipment................133  
Exit...........................004  
Temperature ............158  
Third ........................159  
Three .......................072  
Tool .........................213  
Two..........................071  
Laundry ....................140  
Left ...........................027  
Library ......................141  
Light .........................019  
Living........................030  
Loading.....................142  
Lower .......................094  
Factory.....................134  
Fathers ....................211  
Fence.......................135  
Fifth..........................218  
Fire...........................040  
First .........................136  
Five..........................074  
Floor.........................029  
Four..........................073  
Fourth.......................217  
Foyer........................137  
Rear .........................088  
Right.........................028  
Room........................018  
Up............................025  
Upper.......................187  
Upstairs ...................183  
Utility........................185  
Machine....................143  
Master ......................144  
Medical.....................014  
Mothers....................212  
Motion ......................145  
Call........................... 009  
Central ..................... 089  
Chime ...................... 054  
Closed...................... 126  
Computer ................. 127  
Console.................... 066  
s...............................007  
Second .....................056  
Service .....................150  
Seven .......................076  
Seventh ....................220  
Shed.........................151  
Shop.........................152  
West ........................215  
Window....................017  
Wing ........................216  
Nine..........................078  
Ninth.........................222  
Zero.........................069  
Zone ........................002  
Custom Word Substitutes for VIP Module Annunciation  
A substitute word can be programmed for each of the 20 custom words used in your alpha zone descriptions. The VIP Module  
announces this substitute word in place of the custom word that is displayed on the alpha keypad. For example, a zone  
display of "Johns Bedroom" could be announced as "Sons Bedroom," as there is no annunciation for the custom word "John."  
Note that if a substitute word is not assigned, the VIP Module will not annunciate the zone descriptor at all, but will only  
annunciate the zone number.  
To enter custom word substitutes, do the following:  
1. From Data Field Programming Mode, press #93 to display the "ZONE PROG?" prompt.  
2. Press [0] (NO) to each menu option until the "CUSTOM INDEX ?" prompt is displayed.  
PROMPT  
EXPLANATION  
Enter 1 at this prompt.  
CUSTOM INDEX ?  
1=YES 0=NO  
0
Enter the custom word number (01-20) for which a voice substitute is desired. Enter 00 to quit this  
Programming Mode.  
CUSTOM WORD NO.  
00=QUIT  
Press [] to accept entry.  
Enter the 3-digit substitute word index number from the Relay Voice Descriptors and Custom Word  
Substitutes Vocabulary list in the Relay Voice Descriptors part of this section.  
01 ENTER INDEX #  
Press [] to accept entry.  
The "CUSTOM WORD NO." prompt is displayed. Enter the next custom word number to be substituted, or  
enter 00 to quit.  
26 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
System Layout Worksheets  
Before programming any security system, you should first define the installation. To help you lay out a partitioned  
system, use the following worksheets. This will further simplify the programming process.  
PARTITIONS  
Descriptor  
(4-char max)  
Prim.  
Sub. #  
Sec.  
Sub. #  
Alpha Default Message  
(32-character maximum)  
Partition #  
Partition 1  
Partition 2  
Keyswitch Arming Partition Assignment (1-2):  
Wireless Keypad Partition Assignment (1-2):  
Voice Module Partition Assignment (1-2):  
Use Partition Descriptor (yes/no)?  
COMMUNICATION OPTIONS BY PARTITION  
Part. 1  
Option  
Part. 2  
Swinger Suppression Count 00-15; 00=no suppression  
Cancel Report After Disarm  
Dialer Reports for Panic (* + 1)  
Dialer Reports for Panic (# + 3)  
Dialer Reports for Panic (* + #)  
Dialer Reports for Duress  
Burglary Alarm Communications Delay (16 sec.)  
SYSTEM DEFINITIONS BY PARTITION (enter values or yes/no)  
Part. 1 Part. 2  
Option  
Entry Delay #1 (00, 30-225 seconds):  
Exit Delay #1 (00, 45-225 seconds):  
Entry Delay #2 (00, 30-225 seconds):  
Exit Delay #2 (00, 45-225 seconds):  
Quick Arming  
Multiple Alarms per Arming  
Console Panic for Zone 95 (* + 1)  
Console Panic for Zone 96 (# + 3)  
Console Panic for Zone 99 (* + #)  
Allow Sign-on (GOTO function)  
Non-Bypassable Zone*  
Sounder Timeout Duration for Bell (2 min. increments)  
Console Annunciation During Entry**  
Console Annunciation During Exit  
Confirmation of Arming Ding for Bell  
Chime on Bell  
Access Control Relay (field 1*76)  
*Can be any zone 01-64.  
**no = 3 beeps; yes = continuous  
PRINTER OPTIONS  
12- or 24-hour Time format  
EVENT LOG TYPES  
Option  
Alarm  
No  
Yes  
Trouble  
Bypass  
Open/Close  
System  
27 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DEVICES (keypads, 4204, rf receivers, vip module, lrr)  
Sound  
Opt  
House  
ID  
Device Types:  
Addr  
Type  
Part  
00 = Device Not Used  
01 = Alpha Console  
02 = Fixed-Word Console  
03 = RF Receiver  
04 = Relay Module  
05 = Voice Module  
NOTES:  
00.  
01.  
02.  
03.  
04.  
05.  
06.  
07.  
08.  
09.  
10.  
11.  
12.  
13.  
14.  
15.  
Address 04 must be used for the Voice Module,  
if used.  
Console Sounder Options:  
0 = No Suppression  
1 = Suppress Arm/Disarm and Entry/Exit Beeps  
2 = Suppress Chime Mode Beeps Only  
3 = Suppress Arm/Disarm, Entry/Exit and Chime  
Mode Beeps  
Defaults:  
Addresses 00 = Alpha Keypad; No Suppression  
Addresses 01 = Alpha Keypad; No Suppression  
Addresses 02 = Alpha Keypad; No Suppression  
Addresses 03 = Alpha Keypad; No Suppression  
ACCESS CODES & USER DEFINITIONS FOR PARTITIONS 1 & 2  
4-digit  
Security  
Code  
Partition 1  
Partition 2  
2-Digit  
User #  
Auth.  
Level  
Open/  
Close  
RF Key  
2-Digit  
User #  
Auth.  
Level  
Open/  
Close  
RF Key  
Authority Levels: 1=Master (arm, disarm, bypass, and/or modify lower level users)  
2=Manager (arm, disarm, bypass, and/or modify lower level users)  
3=Operator A (arm, disarm, bypass)  
4=Operator B (arm, disarm)  
5=Operator C (arm, disarm only if system was armed with this code)  
6=Duress code (arm, disarm, triggers silent panic alarm)  
28 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
29 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
30 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
31 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ZONE DEFINITIONS FOR KEYPAD PANIC ZONES 95, 96, & 99  
Enter yes/no for each  
partition (field *22)  
Zone  
No.  
Zone  
Type  
Report  
Code  
Zone Information (part numbers) &  
Alpha Descriptor (3 words max.)  
1
2
95  
96  
99  
ZONE DEFINITIONS FOR SYSTEM ZONES; 70, 88; 89, 90, 91 & 97  
Zone Information (part numbers)  
Zone  
No.  
Zone Report  
Type Code  
&
Alpha Descriptor (3 words max.)  
70  
88  
89  
90  
91  
97  
Zone Types:  
00=zone not used  
01=entry/exit 1  
02=entry/exit 2  
03=perimeter  
05=day/night burglary  
06=24-hour silent  
07=24-hour audible  
08=24-hour auxiliary  
09=supervised fire  
10=interior (w/delay)  
20=arm stay  
21=arm away  
22=disarm  
23=no alarm response  
04=interior (follower)  
Input Types:  
00=not used  
05=RF button transmitter  
01=hardwired  
03=supervised RF transmitter  
04=unsupervised RF transmitter  
06=serial number polling loop  
07=Dip switch-type polling loop  
08=right loop dip switch polling loop  
32 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Relay Outputs Worksheets  
Applicable only if relays (4204) or X-10 devices are used.  
Programmed in the #93 Menu Mode in the Relay Programming Section. Fill in the worksheet below and follow the  
procedure in the installation instructions as you enter the data during the displays and prompts that appear in sequence.  
Notes: 1. For 4204 the Device Programming section must be programmed for the device address. Set the DIP  
switches on the device for that address.  
2. For X-10 devices, use the 1361X10 transformer in place of the transformer that comes in the box with the  
control panel.  
Dev Add 4204  
or House Code  
for X-10  
Relay # for 4204  
or  
Unit Code for X-10  
1=4204  
2=X-10  
RELAY  
DEV #  
S T A R T  
EV/ZL ZT / P  
S T O P  
ZL ZT / P  
Restrict  
A
1.  
2.  
3.  
4.  
5.  
6.  
7.  
8.  
A =  
EV = EVENT  
ZL = ZONE LIST  
DEVICE ACTION  
0 = No Response; 1 = Close for 2 sec; 2 = Close and stay closed; 3 = Pulse on and off  
0 = Not used; 1 = Alarm; 2 = Fault; 3 = Trouble; 4 = Restore  
1-4, 0 = Not Used  
NOTES: "START" ZONE LIST: Upon alarm, fault, trouble or restore of ANY zone in this list, device action starts.  
"STOP" ZONE LIST: Upon restore of ALL zones in this list, device action stops. It need not be same list as used for START.  
ZT = ZONE TYPE/SYSTEM OPERATION  
Choices for Zone Types are:  
00=zone not used  
01=entry/exit 1  
02=entry/exit 2  
03=perimeter  
05=day/night burglary  
06=24-hour silent  
07=24-hour audible  
08=24-hour auxiliary  
09=supervised fire  
10=interior (delay)  
20=arm stay  
21=arm away  
22=disarm  
23=no alarm response  
04=interior (follower)  
NOTE: Any zone in "ZT" for Start, going into alarm, fault, or trouble will activate the relay.  
Any zone in "ZT" for Stop, that restores will stop the relay action.  
Choices for System Operation are:  
00 = No Response (Not Used)  
01 = Entry/Exit #1  
02 = Entry/exit #2  
23 = No Alarm Response  
31 = End of Exit Time  
32 = Start of Entry Time  
33 = Any Burglary Alarm  
34 = Code + [#] + 71 Key Entry  
35 = Code + [#] + 72 Key Entry  
36 = At Bell Timeout **  
37 = 2 Times Bell Timeout **  
38 = Chime  
39 = Fire Alarm  
40 = Bypassing  
31 = End of Exit Time  
41 = AC Power Fail  
43 = Communication failure  
44 = RF Low Battery  
45 = Polling Loop Failure  
51 = RF Receiver Failure  
52 = Kissoff  
03 = Perimeter  
04 = Interior Follower  
05 = Trouble Day/Alarm Night  
06 = 24-Hr. Silent  
54 = Fire Zone Reset  
55 = Disarm + 1 Minute  
56 = XX Minutes (enter XX in field 1*74) *  
57 = YY Seconds (enter YY in field 1*75) *  
58 = Duress  
60 = Audio Alarm Verification (must be  
selected for both START and STOP  
operation)  
07 = 24-Hr. Audible  
08 = 24-Hr. Auxiliary  
09 = Fire Alarm or Trouble  
10 = Interior W/Delay  
20 = Arming-STAY  
21 = Arming-AWAY  
22 = Disarming (Code + Off)  
42 = System Battery Low  
*
Stop condition only  
** Or at disarming, whichever occurs earlier  
P =  
PARTITION No. 1-2, 0 = Any  
33 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
ZONE LISTS FOR RELAY DEVICES Programmed in the #93 Menu Mode in the Relay Programming Section. Fill in the  
required data on the worksheet below and follow the procedure shown earlier in this Programming Guide as you enter the  
data during the displays and prompts that appear in sequence. Up to 4 zone lists may be created  
Note: Record desired zone numbers below. More or fewer boxes than shown may be needed, as any list may include any or  
all of system's zone numbers.  
Zone List 1: Started or stopped by zone numbers (enter 00 to end entries).  
Zone List 2: Started or stopped by zone numbers (enter 000 to end entries).  
Zone List 3: Started or stopped by zone numbers (enter 000 to end entries).  
Zone List 4: Started or stopped by zone numbers (enter 000 to end entries).  
34 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
VISTA-40 Summary of Connections Diagram  
P O L L I N G L O O P  
( F a s t / N o r m a l ) L o o p  
P r o g r a m m a b l e R e s p o n s e  
B R E A K D E T E C T O R L O O P  
L A T C H I N G T Y P E G L A S S  
( A l s o s u p p o r t s N O / N C B u r g c o n t a c t s )  
D E T E C T O R L O O P  
2 - W I R E S M O K E  
D a t a o u t  
D a t a i n  
N O C O N N E C T I O N  
R E D ( + )  
B L K ( - )  
35 –  
Download from Www.Somanuals.com. All Manuals Search And Download.  
165 Eileen Way, Syosset, New York 11791  
Copyright © 2004 Honeywell International, Inc.  
¬1ꢀꢁꢁꢂ359ꢃꢄlꢅ  
N7001PRV5 5/04 Rev A  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Saw G9744Z2 User Manual
Haier Flat Panel Television HL15E User Manual
Haier Washer Dryer HWDC1000TXVE User Manual
Harbor Freight Tools Log Splitter 40318 User Manual
Harbor Freight Tools Power Hammer 93364 User Manual
Harman Kardon Home Theater System HK3380 User Manual
HP Hewlett Packard Network Card PCI 9111DG HR User Manual
HP Hewlett Packard Network Router 2040D User Manual
IBM Computer Monitor 07N2250 User Manual
iLive MP3 Docking Station IC2807BLK User Manual