Honeywell Heat Pump T8511G User Manual

/
T8511G Deluxe Heat Pump  
Zone Thermostat  
INSTALLATION INSTRUCTIONS  
APPLICATION  
The T8511G Deluxe Heat Pump Zone Thermostat provides electronic control of 24 Vac heat pump zoned systems. Refer  
to Table 1 for a general description of the thermostat.  
Table 1. Description of T8511 Thermostat.  
Model  
Application  
Powering Method  
Requires common wire to Automatic or Em Heat-Heat-Off-  
power supply Manual Cool-Auto  
Changeover System Selection Fan Selection  
T8511G Zone 1 on MABS II or  
TotalZone® system  
On-Auto  
Do not install the thermostat where it can be affected by:  
drafts, or dead spots behind doors and in corners.  
hot or cold air from ducts.  
radiant heat from sun or appliances.  
concealed pipes and chimneys.  
unheated (uncooled) areas such as an outside wall  
behind the thermostat.  
RECYCLING NOTICE  
If this control is replacing a control that contains  
mercury in a sealed tube, do not place your old  
control in the trash.  
Contact your local waste management authority for  
instructions regarding recycling and the proper  
disposal of the old thermostat.  
Wallplate Installation  
The thermostat can be mounted horizontally on the wall or  
on a 2 in. x 4 in. wiring box. Position wallplate horizontally  
on the wall or on a 2 in. x 4 in. wiring box.  
INSTALLATION  
1. Position and level the wallplate (for appearance  
only). The thermostat will function properly even  
when not level.  
2. Use a pencil to mark the mounting holes. See Fig. 2.  
3. Remove the wallplate from the wall and drill two  
3/16 inch holes in the wall (if drywall) as marked.  
For firmer material such as plaster, drill two 7/32 inch  
holes. Gently tap anchors (provided) into the drilled  
holes until flush with the wall.  
4. Position the wallplate over the holes, pulling wires  
through the wiring opening.  
5. Loosely insert the mounting screws into the holes.  
6. Tighten mounting screws.  
When Installing this Product…  
1. Read these instructions carefully. Failure to follow  
the instructions can damage the product or cause a  
hazardous condition.  
2. Check the ratings given in the instructions and on  
the product to make sure the product is suitable for  
your application.  
3. Installer must be a trained, experienced service  
technician.  
4. After completing installation, use these instructions  
to check out the product operation.  
Location  
Install the thermostat about 5 ft (1.5m) above the floor in  
an area with good air circulation at average temperature.  
See Fig. 1.  
®U.S. Registered Trademark  
Copyright © 1997 Honeywell Inc. •  
All Rights Reserved  
69-1052-1  
Download from Www.Somanuals.com. All Manuals Search And Download.  
T8511G DELUXE HEAT PUMP ZONE THERMOSTAT  
OUTDOOR  
TEMPERATURE  
SENSOR  
Mounting Thermostat  
1. Engage tabs at the top of the thermostat and  
wallplate. See Fig. 6.  
THERMOSTAT  
2. Press lower edge of case to close and latch.  
O
G
B
L
C
R
Y
E
W2 OT OT  
NOTE: To remove the thermostat from the wall, first pull out  
at the bottom of the thermostat; remove top last.  
ZONE 1  
T8  
T7  
T6  
T5  
T4  
A. ENGAGE TABS AT TOP OF THERMOSTAT AND WALLPLATE.  
O1  
G1  
B1  
E1  
CHANGEOVER  
CONTROL  
M1  
M12188  
B. PRESS LOWER EDGE OF CASE TO LATCH.  
Fig. 3. Typical wiring diagram for T8511G with zone 1  
MABS II control panel.  
OUTDOOR  
TEMPERATURE  
SENSOR  
(OPTIONAL)  
THERMOSTAT  
1
B
E
L
L
G
G
Y
R
O
W2  
C
OT OT  
M6798A  
Fig. 6. Mounting thermostat on wallplate.  
W2  
Y
R
W
M6 M4 M1  
TotalZone® PANEL THERMOSTAT CONNECTIONS  
Using Thermostat Keys  
The thermostat keys are used to:  
1
WHEN USING W2 ON THE THERMOSTAT TO CONTROL THE SECOND  
STAGE OF HEATING, BE SURE THE STAGE JUMPER IS IN PLACE ON  
THE TZ PANEL.  
set temperature,  
M12189  
display present setting,  
configure Installer Setup,  
check System-Test,  
display outdoor temperature (select models),  
set the system operation,  
set the fan operation.  
Fig. 4. Typical wiring diagram for T8511G with zone 1  
TotalZone® control panel.  
See Fig. 7 for the location of the keys.  
INCREASE  
TEMPERATURE  
SETTING  
DECREASE  
TEMPERATURE  
SETTING  
i
DISPLAY PRESENT  
SETTINGS AND SCROLL  
THROUGH INSTALLER  
SETUP MODES  
(INFORMATION KEY)  
M6801  
FOR STRAIGHT  
INSERTION STRIP  
5/16 IN. (8 MM).  
Fig. 7. Key locations and descriptions.  
FOR WRAPAROUND  
INSERTION STRIP  
7/16 IN. (11 MM).  
M4826  
Fig. 5. Proper wiring technique.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
69-1052—1  
T8511G DELUXE HEAT PUMP ZONE THERMOSTAT  
The Installer Setup is used to customize the thermostat to  
specific systems. Some of the options include temperature  
display, changeover and outdoor temperature display.  
Installer Setup numbers are listed in Table 2. The table  
includes all the configuration options and the factory  
settings for the T8511G.  
SETTINGS  
System and Fan Settings  
System settings control the thermostat operation as  
follows:  
Em Heat: Emergency heat relay is automatically  
controlled by the thermostat. The cooling system is  
off. The compressor is de-energized.  
Heat: The thermostat controls the heating.  
Off: Both the heating and cooling are off.  
Cool: The thermostat controls the cooling.  
Auto: The thermostat automatically changes between  
heating and cooling operation, depending on the  
indoor temperature.  
A combination of key presses are required to use the  
Installer Setup feature.  
To enter the Installer Setup, press and hold the  
Information key with the increase and decrease  
i
keys until the first number is displayed. All display  
segments appear for approximately three seconds  
before the number is displayed. See Fig. 9 and 10.  
To advance to the next Installer Setup, press the  
Information  
i
key.  
Fan settings control the system fan as follows:  
On: Fan operates continuously.  
Auto: Fan operates with equipment.  
To change a setting, use the increase and de-  
crease keys.  
To exit the Installer Setup, press and hold the  
Information  
i
key until the display returns to normal  
The system default setting is Heat and the fan default  
setting is Auto. Use the keyboard to change to the desired  
settings. See Fig. 8.  
(approximately three seconds). The display will scroll  
the numbers backwards to get to the normal display.  
The Installer Setup is automatically exited if no key  
presses are made for ten minutes.  
Em Ht Temporary Setting  
Aux Ht  
Remote  
Room  
%Humid  
Outdoor  
i
System  
System  
Fan  
Press to select  
heating or cooling  
equipment.  
Press to select  
heating or cooling  
equipment.  
Repl  
Em. Ht.-Emergency heating  
HeatHeating equipment  
On— Fan runs continuously  
Auto—Fan runs when  
heating or cooling  
System  
Fan  
Off  
No equipment  
Cool—Cooling equipment  
Auto—Thermostat  
automatically selects  
heating and cooling  
equipment.  
equipment operates  
Wait  
Heat Cool  
Batt  
Fan  
System  
Fan  
Em HeatOffCool Auto Only OnAuto  
1
M4844  
Fig. 9. Display of all the segments of the LCD.  
INSTALLER SETUP  
MODE NUMBER DISPLAY  
(COLUMN 2 OF TABLE 2)  
M10147  
CHECK LIGHT ON SELECT MODELS  
1
Fig. 8. Thermostat System and Fan key location.  
FACTORY SETTING OR  
OTHER CHOICE DISPLAY  
(COLUMN 3 OR 5 OF TABLE 2)  
NOTE: Always press the keys with your fingertip or  
similar blunt tool. Sharp instruments like a pen or  
pencil point can damage the keyboard.  
Temperature Settings  
The default setpoint for heat is 70°F (21°C) and for cool is  
78°F (25.5°C). Press the increase or decrease key to  
change the present setting to change between heat and  
cool, press the Information  
i
key until the setting to be  
changed appears. Press the increase or decrease ▼  
key to adjust the setting.  
M10105A  
Fig. 10. Display of Installer Setup number and setting.  
INSTALLER SETUP  
IMPORTANT  
NOTE: For most applications, the thermostat factory  
settings will not need to be changed. Review the  
factory settings in Table 2 and if no changes are  
necessary, go to the Installer System-Test  
section.  
Only configurable numbers are shown on the  
device. Example: If thermostat does not have  
outdoor temperature capability, Installer Setup  
Number 24 will not be displayed. Review Table 2  
factory-settings and mark any desired changes in  
the Actual Settings column. When Installer Setup  
is complete, review the settings to confirm that  
they match the system.  
69-1052—1  
Download from Www.Somanuals.com4. All Manuals Search And Download.  
T8511G DELUXE HEAT PUMP ZONE THERMOSTAT  
Table 2. Thermostat Installer Setup Options.  
Installer Setup  
Number  
Other Choices  
Factory Setting  
(Press or key to change)  
(Press  
i
key  
Actual  
Setting  
to change)  
Select  
Not used  
Display  
Description  
Display  
Description  
01 thru 04  
06  
06  
05  
06  
07  
Stage 2  
Heating cycle  
rate  
03, 06 03—3 cph used for hot water  
or 09  
systems  
Not used  
Emergency heat  
06—6 cph used for heat pump  
systems  
09—9 cph used for electric heat  
systems  
Not used  
08 thru 11  
12  
Changeover  
01  
Manual changeover  
00 or 00—Automatic changeover  
02  
01  
02—Auto only  
Not used  
13  
14  
Degree tempera-  
ture display  
00  
Temperature is  
displayed in °F  
Temperature is displayed  
in °C  
Not used  
15 thru 18  
19  
Extended fan  
operation in  
heating  
00  
No extended fan  
operation after the  
call for heat ends  
01  
Fan operation is extended  
90 seconds after the call for  
heat ends  
Extended fan  
operation in  
cooling  
20  
00  
No extended fan  
operation after the  
call for cool ends  
01  
Fan operation is extended  
90 seconds after the call for  
cool ends  
Not used  
21 thru 23  
24  
Outdoor  
00  
No outdoor  
temperature is  
displayed  
01  
Outdoor temperature is  
displayed. Needs a C7089B1000  
Outdoor Sensor to operate.  
temperature  
a
display  
Not used  
25 thru 32  
33  
Minimum off time  
for the  
compressor  
05  
5 minute minimum off 00, 01, Minimum number of minutes  
time for the  
compressor  
02, 03 (0 thru 5) the compressor will be  
or 04  
off between calls for the  
compressor  
Heating setpoint  
range stop  
34  
35  
36  
90  
48  
00  
Heating setpoint can 40 thru Number can be set anywhere  
a
be set no higher than 90  
90°F  
between 40 and 90 in 1°F  
increments  
Cooling setpoint  
Cooling setpoint can 48 thru Number can be set anywhere  
a
range stop  
be set no lower than 99  
48°F  
between 48 and 99 in 1°F  
increments  
System on  
indicator  
LCD On symbol is  
displayed when  
01  
Display is disabled  
(flame=heat,  
snowflake=cool)  
is displayed  
system is energized  
a
Temperature  
display  
adjustment  
37  
00  
No difference in  
displayed  
temperature and  
actual room  
-3 thru 01—Display adjusts to 1°F higher  
03  
than actual room temperature  
02—Display adjusts to 2°F higher  
than actual room temperature  
03—Display adjusts to 3°F higher  
than actual room temperature  
temperature  
-1—Display adjusts to 1°F lower  
than actual room temperature  
-2—Display adjusts to 2°F lower  
than actual room temperature  
-3—Display adjusts to 3°F lower  
than actual room temperature  
a Available on select models.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
69-1052—1  
T8511G DELUXE HEAT PUMP ZONE THERMOSTAT  
IMPORTANT  
Em Ht Temporary Setting  
Aux Ht  
Remote  
Room  
%Humid  
Outdoor  
Review the settings to confirm that they match  
the system. To exit the Installer Setup, press and  
hold the Information  
i
key until the display  
returns to normal (approximately three seconds).  
Repl  
Wait  
Heat Cool  
Batt  
System  
Fan  
INSTALLER SYSTEM-TEST  
Use the Installer System-Test to check the thermostat  
operation. Refer to Table 3 for a list of the available  
system-tests.  
Em HeatOffCool Auto Only OnAuto  
M4844  
Fig. 11. Display of all the segments of the LCD.  
To start the system-test:  
CAUTION  
The minimum off time for compressors is bypassed  
during the Installer System-Test. Equipment damage  
can occur if the compressor is cycled too quickly.  
Press and hold the increase and decrease keys at  
the same time, until two zeros appear. All segments of the  
LCD will be displayed before the two zeros appear. See  
Fig. 11 and 12.  
M6792  
TEST MODE NUMBER  
Table 3. Tests Available In the Installer System-Test.  
Test  
Fig. 12. Display of test number.  
Refer to Table 4 for the directions and results of the  
specific tests.  
Number  
System-Test Description  
10-19  
Heating equipment can be turned on  
and off  
NOTE: Press and hold the increase and decrease ▼  
keys together for three seconds to exit the  
system-test. The system-test will time out after  
ten minutes without any key presses.  
20-29  
30-39  
Emergency heat (select models)  
equipment can be turned on and off  
Cooling equipment can be turned on  
and off  
40-49  
60-69  
70-79  
Fan equipment can be turned on and off  
Keyboard keys test  
Thermostat information including date  
code and software versions are displayed  
Table 4. Installer System-Test Options.  
Key to  
Press  
Test  
Number  
Description  
Heating Equipment System-Test  
i
10  
11  
12  
11  
10  
Enter heating equipment system-test.  
Stage-one heat comes on. System fan is also energized.  
Stage-two heat comes on. Stage-one heat and system fan remain on.  
Stage-two heat turns off.  
Stage-one heat and system fan turn off.  
Emergency Heating Equipment System-Test (select models)  
i
20  
21  
20  
Changing from heating to emergency heating equipment system-test.  
Emergency heat comes on. System fan also comes on.  
Emergency heat turns off.  
Cooling Equipment System-Test  
i
30  
31  
30  
Change from heating or emergency heating to cooling equipment system-test.  
Cool and system fan come on.  
Cool and system fan turn off.  
(Continued)  
69-1052—1  
Download from Www.Somanuals.com6. All Manuals Search And Download.  
T8511G DELUXE HEAT PUMP ZONE THERMOSTAT  
Table 4. Installer System-Test Options (Continued).  
Description  
Key to  
Press  
Test  
Number  
Fan Equipment System-Test  
i
40  
41  
40  
Change from cooling to fan equipment system-test.  
Fan comes on.  
Fan turns off.  
Key Operation System-Test  
IMPORTANT  
Test numbers will only be displayed when the system is configured for the selected function.  
EXAMPLE: Numbers 60, 61 and 62 are the only numbers that will be displayed when a system  
is configured for heat only.  
System Key System-Test  
i
60  
61  
62  
63  
64  
65  
Change from cooling or fan to key operation system-test.  
Heat Test Number is displayed.  
System  
System  
System  
System  
System  
Off Test Number is displayed.  
Cool Test Number is displayed.  
Auto Test Number is displayed.  
Emergency heat Test Number is displayed.  
Fan Key System-Test  
Fan  
Fan  
68  
69  
Fan on Test Number is displayed.  
Fan off Test Number is displayed.  
NOTE: Press and hold the increase and decrease keys together for three seconds to exit the system-test. The  
system-test will time out after ten minutes without any key presses.  
3. Press the increase key again to display the  
THERMOSTAT INFORMATION  
software identification code.  
1. Press the Information  
i
key to access the thermo-  
stat information.  
M4866  
4. Press the increase key again to display the  
M4864  
software revision number (Example: 001=Revision  
number 1).  
2. Press the increase key to display the production  
date code. The first two large digits are the month  
and the third digit is the last digit of the year (Ex-  
ample: 027=February 1997).  
M6791  
M10444  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
69-1052—1  
T8511G DELUXE HEAT PUMP ZONE THERMOSTAT  
5. Press the increase key again to display the  
CHECKOUT  
EEPROM identification code.  
Outdoor Temperature Sensor  
(Where Applicable)  
Allow the outdoor temperature sensor to soak in the  
outdoor air for a minimum of five minutes before taking a  
reading. With an accurate thermometer (±1°F [±0.5°C]),  
measure the temperature at the sensor location, allowing  
time for the thermometer to stabilize before reading. Match  
the thermometer reading to the outdoor temperature  
display at the thermostat.  
M4867  
6. Press and hold the increase and decrease ▼  
keys together, until the room temperature is  
displayed, to exit the system-test. The system-test  
times out after ten minutes without any key presses.  
TROUBLESHOOTING GUIDE  
Symptom  
Possible Cause  
Action  
Display will not  
come on.  
Thermostat is not being  
powered.  
Check that C terminal is connected to the system  
transformer.  
Check for 24 Vac between C and R terminals.  
If missing 24 Vac:  
check if the circuit breaker is tripped—reset the  
circuit breaker.  
check if the system fuse is blown—replace the  
fuse.  
check if the power switch on the HVAC equipment  
is in the Off position—set to the On position.  
check wiring between thermostat and HVAC  
equipment—replace any broken wires and tighten  
any loose connections.  
If 24 Vac is present, proceed with troubleshooting.  
Thermostat microprocessor is  
locked up.  
Remove the thermostat from the wallplate for 2 minutes. After  
2 minutes, replace the thermostat on the wallplate.  
Temperature  
Room temperature display has Enter Installer Setup number 37 and reconfigure the display.  
display is incorrect. been reconfigured.  
Thermostat is configured for °F Enter Installer Setup number 14 and reconfigure the display.  
or °C displaya.  
Bad thermostat location.  
Relocate the thermostat.  
The upper or lower temperature Check the temperature setpoints:  
Temperature  
limits were reached.  
Heating limits are 40 to 90°F (4.5 to 32°C)  
Cooling limits are 48 to 99°F (7 to 35°C).  
settings will not  
change. (Example:  
Cannot set the  
heating higher or  
the cooling lower.)  
The setpoint temperature range Check Installer Setup numbers 34 and 35 and reconfigure the  
stops were configured. setpoint stops.  
a Available on select models.  
(Continued)  
69-1052—1  
Download from Www.Somanuals.com8. All Manuals Search And Download.  
T8511G DELUXE HEAT PUMP ZONE THERMOSTAT  
Troubleshooting Guide (Continued).  
Symptom  
Possible Cause  
Action  
Heating will not  
come on.  
No power to the thermostat.  
Check that C terminal is connected to the system  
transformer.  
Check for 24 Vac between C and R and between R and Y1  
terminals.  
If missing 24 Vac:  
check if the circuit breaker is tripped—reset the  
circuit breaker.  
check if the system fuse is blown—replace the  
fuse.  
check if the system switch at the equipment is in  
the Off position—set to On position.  
check wiring between thermostat and HVAC  
equipment—replace any broken wires and tighten  
any loose connections.  
If 24 Vac is present, proceed with troubleshooting.  
Thermostat minimum off time  
is activated.  
Wait up to five minutes for the system to respond.  
System selection is not set to  
Heat.  
Set system selection to Heat.  
Cooling will not  
come on.  
No power to the thermostat.  
Check that C terminal is connected to the system  
transformer.  
Check for 24 Vac between C and R and between R and Y1  
terminals.  
If missing 24 Vac:  
check if the circuit breaker is tripped—reset the  
circuit breaker.  
check if the system fuse is blown—replace the  
fuse.  
check if the system switch at the equipment is in  
the Off position—set to the On position.  
check wiring between thermostat and HVAC  
equipment—replace any broken wires and tighten  
any loose connections.  
If 24 Vac is present, proceed with troubleshooting.  
Thermostat minimum off time is  
activated.  
Wait up to five minutes for the system to respond.  
Enter Installer Setup number 33. Reconfigure minimum off  
time (if required).  
System selection is not set to  
Cool.  
Set system selection to Cool.  
System on indicator Heating equipment is not  
Verify operation of heating equipment in self-test.  
(flame=heat,  
operating.  
snowflake=cool) is  
displayed, but no  
warm or cool air is  
coming from the  
registers.  
System on indicator Option not activated.  
is not displayed,  
Enter Installer Setup number 36 and reconfigure to 00.  
but heating or  
cooling system is  
operating  
Outdoor  
Option not activated.  
Enter Installer Setup number 24 and set to 01. Thermostat  
must have OT terminals and a C7089B1000 installed.  
temperature  
not displayeda  
Outdoor sensor is connected  
incorrectly.  
Refer to C7089B1000 installation instructions and check wiring  
between the thermostat and sensor.  
Outdoor  
temperature  
display is incorrecta  
Wrong sensor.  
Replace sensor with C7089B1000 sensor.  
a Available on select models.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
69-1052—1  
69-1052—1  
Download from Www.Somanuals.com10. All Manuals Search And Download.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
69-1052—1  
Helping You Control Your World®  
Honeywell Trol-A-Temp  
57 Bushes Lane  
Elmwood Park, NJ 07407-3204  
(201) 794-8004  
(800) 828-8367  
Fax: (201) 794-1359  
69-1052—1 J.H. Rev. 6-97 Printed in Taiwan R.O.C.  
Download from Www.Somanuals.com. All Manuals Search And Download.  

GrandTec Camcorder CMS 4000 User Manual
Hans Grohe Outdoor Shower 28532XX1 User Manual
Honeywell Thermostat 191108AJ User Manual
HP Hewlett Packard All in One Printer 2405 Q3086A User Manual
HP Hewlett Packard Server AB300A User Manual
HP Hewlett Packard Server DL585 G5 User Manual
HP Hewlett Packard Telescope HP 54520 User Manual
HP Hewlett Packard Vacuum Cleaner 8350A User Manual
HP Hewlett Packard Water Pump PCN=71576526 User Manual
Huffy Fitness Equipment 104 03P N211956B User Manual