Honeywell Door 6150V User Manual

K0022V3 3/09 Rev. A  
ADEMCO 6150V & 6160V  
Voice Remote Keypads  
INSTALLATION AND SETUP GUIDE  
GENERAL INFORMATION  
Function  
Equivalent Key Pairs  
Keys  
A
B
C
D
The ADEMCO 6150V and ADEMCO 6160V are addressable  
remote keypads designed for use with ADEMCO control  
panels and provide the following features:  
[1] and [*]  
[*] and [#]  
[3] and [#]  
NONE  
Backlit Display  
Programmable Function Keys  
Built-in Sounder  
Voice Chime  
Voice Status  
Message Center  
Function keys must be held down for at  
least 2 seconds to activate the programmed  
function.  
If functions other than panics are assigned  
to the programmable function keys,  
programmed panics must be initiated by  
pressing the programmed key pair.  
Supervised by control panel (if supported)  
Notes:  
When used with the ADEMCO VISTA-15P/VISTA-  
20P control panels, address 16 must be assigned to  
the first keypad. Additional keypads must be  
assigned to address 17 – 23. Refer to Setting The  
Keypad Options.  
FUNCTION KEY LABELS  
A set of adhesive-backed labels with some typical function  
symbols (i.e., fire, police, personal emergency, etc.) is  
provided. These labels can be placed on or next to the keys  
to identify each key's function for the end user (as  
determined by the capability and programming of the  
control panel; refer to the installation and setup guide for  
the control panel).  
Keypad keys are continuously backlit for convenience.  
Permanent display backlighting is an option on some  
controls (refer to control panel’s instructions for details).  
Voice Chime should only be enabled when used with  
control panels that support the "chime by zone" mode  
(e.g., VISTA-15P/VISTA-20P).  
This mode must be  
enabled at the control panel. Refer to the control panel's  
installation and setup guide for information on how to  
program the chime mode.  
A
Use only zone descriptors supported by this  
keypad. If using zone descriptors not supported  
by this keypad, you must turn voice status and  
voice chime off. Table 1 is a list of applicable zone  
descriptors and index entries. Refer to the control  
panel’s installation and setup guide for information  
about how to program zone descriptors.  
OFF  
MAX  
AWAY  
TEST  
CODE  
STAY  
BYPASS  
CHIME  
1
4
7
2
5
8
0
3
6
9
#
B
SIDE  
VIEW  
INSTANT  
READY  
C
D
For the 6160V ONLY, supervision must be enabled for  
commercial fire installations.  
MOUNTING RELEASE SNAPS  
(Remove case back by pushing up the 2 "snaps" along  
the keypad's bottom edge and pulling the case apart.)  
UL NOTE: ADEMCO 6150V cannot be used for commercial  
fire applications.  
KEYPAD DISPLAYS AND LEDS  
WIRING AND INSTALLATION  
Keypads can be surface mounted using drywall anchors or  
to a single- or double-gang electrical box.  
The keypads have the following display features:  
1. Remove the case back by pushing up the two "snaps"  
along the keypad’s bottom edge and pulling the case  
apart. See diagram above.  
2. Route wiring from the control panel through the  
opening in the case back.  
3. Mount the case back to a wall or electrical box.  
4. Wire directly from the keypad’s terminal block to  
the terminal block on the control board. (See Wiring  
Table that follows.) Use only 16-24 AWG wire.  
Wiring Table (All Keypads)  
Model  
Fixed  
Word  
Display  
X
2-Line  
Alpha  
Display  
2-Digit  
Zone  
Identifier  
X
Custom  
Zone  
Descriptors  
6150V  
6160V  
X
X
The following table identifies the keypad’s LEDs and  
associated functions:  
LED  
Function  
ARMED  
READY  
Lights red when the system is armed in any mode.  
Lights green when the system is "ready" to be  
armed.  
Keypad  
Control Panel  
Data In  
Wire Color  
Green  
MESSAGE  
Flashes red when message waiting or lights red  
(steady) when in record mode.  
G
– Aux Pwr (GND)  
+ Aux. Pwr  
Black  
Red  
PROGRAMMABLE FUNCTION KEYS  
+
Y
The keypad's programmable function keys [A, B, C] are  
normally used for keypad panic functions, but they can be  
programmed for other special functions instead. If they are  
programmed for other special functions, the associated  
keypad key pairs still provide the respective panic alarm (if  
programmed). Refer to the control panel’s Installation &  
Setup Guide for details.  
Data Out  
Yellow  
5. Re-attach the keypad to the case back.  
6. Remove clear protective film from LEDs (6160V  
only).  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Log Splitter 3A2573D User Manual
Graco Marine Sanitation System 248204 User Manual
Graco Septic System TI15596a User Manual
Gravely Lawn Mower CONVERTIBLE 76 User Manual
Hans Grohe Plumbing Product 06596000 User Manual
HP Hewlett Packard Landscape Lighting 8308A User Manual
HP Hewlett Packard Staple Gun C4779x User Manual
Husqvarna Chainsaw 1153178 95 User Manual
Husqvarna Saw K 3600 MKII User Manual
IBM Computer Drive HH LTO User Manual