K0022V3 3/09 Rev. A
ADEMCO 6150V & 6160V
Voice Remote Keypads
INSTALLATION AND SETUP GUIDE
GENERAL INFORMATION
Function
Equivalent Key Pairs
Keys
A
B
C
D
The ADEMCO 6150V and ADEMCO 6160V are addressable
remote keypads designed for use with ADEMCO control
panels and provide the following features:
[1] and [*]
[*] and [#]
[3] and [#]
NONE
• Backlit Display
• Programmable Function Keys
• Built-in Sounder
•Voice Chime
•Voice Status
•Message Center
•
Function keys must be held down for at
least 2 seconds to activate the programmed
function.
If functions other than panics are assigned
to the programmable function keys,
programmed panics must be initiated by
pressing the programmed key pair.
• Supervised by control panel (if supported)
Notes:
•
•
When used with the ADEMCO VISTA-15P/VISTA-
20P control panels, address 16 must be assigned to
the first keypad. Additional keypads must be
assigned to address 17 – 23. Refer to Setting The
Keypad Options.
FUNCTION KEY LABELS
A set of adhesive-backed labels with some typical function
symbols (i.e., fire, police, personal emergency, etc.) is
provided. These labels can be placed on or next to the keys
to identify each key's function for the end user (as
determined by the capability and programming of the
control panel; refer to the installation and setup guide for
the control panel).
•
•
Keypad keys are continuously backlit for convenience.
Permanent display backlighting is an option on some
controls (refer to control panel’s instructions for details).
•
Voice Chime should only be enabled when used with
control panels that support the "chime by zone" mode
(e.g., VISTA-15P/VISTA-20P).
This mode must be
enabled at the control panel. Refer to the control panel's
installation and setup guide for information on how to
program the chime mode.
A
•
Use only zone descriptors supported by this
keypad. If using zone descriptors not supported
by this keypad, you must turn voice status and
voice chime off. Table 1 is a list of applicable zone
descriptors and index entries. Refer to the control
panel’s installation and setup guide for information
about how to program zone descriptors.
OFF
MAX
AWAY
TEST
CODE
STAY
BYPASS
CHIME
1
4
7
2
5
8
0
3
6
9
#
B
SIDE
VIEW
INSTANT
READY
C
D
•
For the 6160V ONLY, supervision must be enabled for
commercial fire installations.
MOUNTING RELEASE SNAPS
(Remove case back by pushing up the 2 "snaps" along
the keypad's bottom edge and pulling the case apart.)
UL NOTE: ADEMCO 6150V cannot be used for commercial
fire applications.
KEYPAD DISPLAYS AND LEDS
WIRING AND INSTALLATION
Keypads can be surface mounted using drywall anchors or
to a single- or double-gang electrical box.
The keypads have the following display features:
1. Remove the case back by pushing up the two "snaps"
along the keypad’s bottom edge and pulling the case
apart. See diagram above.
2. Route wiring from the control panel through the
opening in the case back.
3. Mount the case back to a wall or electrical box.
4. Wire directly from the keypad’s terminal block to
the terminal block on the control board. (See Wiring
Table that follows.) Use only 16-24 AWG wire.
Wiring Table (All Keypads)
Model
Fixed
Word
Display
X
2-Line
Alpha
Display
2-Digit
Zone
Identifier
X
Custom
Zone
Descriptors
6150V
6160V
X
X
The following table identifies the keypad’s LEDs and
associated functions:
LED
Function
ARMED
READY
Lights red when the system is armed in any mode.
Lights green when the system is "ready" to be
armed.
Keypad
Control Panel
Data In
Wire Color
Green
MESSAGE
Flashes red when message waiting or lights red
(steady) when in record mode.
G
–
– Aux Pwr (GND)
+ Aux. Pwr
Black
Red
PROGRAMMABLE FUNCTION KEYS
+
Y
The keypad's programmable function keys [A, B, C] are
normally used for keypad panic functions, but they can be
programmed for other special functions instead. If they are
programmed for other special functions, the associated
keypad key pairs still provide the respective panic alarm (if
programmed). Refer to the control panel’s Installation &
Setup Guide for details.
Data Out
Yellow
5. Re-attach the keypad to the case back.
6. Remove clear protective film from LEDs (6160V
only).
Download from Www.Somanuals.com. All Manuals Search And Download.
|