Operation Manual
OSD Color Camera
INSTRALLATION
The contents of the package
Check the below contents
8. When operation is incorrect or a malfunction is observed
While operating, if any abnormal condition (strange sound,
VCC-600N/P
Mounting a lens
1. Remove the Protective cap in front of the camera.
2. Confirm the mount ring whether it is for C or CS.
3. Attach the lens to the lens mount ring.
4. If the lens has an Auto Iris mechanism, connect the iris cable to the
LENS in rear of the camera.
smell or smoke) or
observed, stop using the camera immediately, turn the
power off, then contact your supplier.
a
malfunction (no pictures, etc.) is
- VCC-600N/P Camera 1set
※ Thank you for choosing Honeywell VCC-600N/P camera.
Please read these instructions carefully before operating this unit,
and retain this manual for future reference.
- Auto Iris Lens Plug
- L Type Wrench
- Operation Manual (English)
9. Cleaning
① In the case of having no iris amplifier : Set the slide switch to
DC (Down side).
② In the case of having iris amplifier : Set the slide switch VSD
(Upper side)
※ When connecting Auto iris lens, be sure to use the connector to
be recommended by manufacturer.( E4-191, ChuoMusen, Japan)
If you have any problems with this camera, contact your local
supplier to service.
Turn the power off and wipe off the dirt with a dry soft
cloth. If it is extremely dirty, use furniture cleaner to wipe it
off. To clean the lens, use a blower or lens cleaning
tissue. (available from any camera dealer)
CAUTION for SAFETY OPERATION
10. Do not shoot any source of bright light.
1. Water and Moisture
To prevent fire or shock hazard, do not expose this camera
to rain or moisture.
If the objects contain very bright areas, bright vertical or
horizontal lines may appear on the screen. This is called
"smear" , a Phenomenon which often occurs with solid
- state pickups, and is not a malfunction.
VSD LENS PIN CONFIGURATION
DC IRIS LENS PIN CONFIGURATION
3
4
3
4
①③
②④
①③
②④
2. Servicing
1
2
1
2
Do not attempt to disassemble or repair by yourself.
You may be exposed to dangerous voltage or other hazards.
Note that all servicing is qualified service personnel.
Modifications not approved by manufacturer could
void the user's authority to operate the equipment.
3. Power Sources
To prevent electric shocks and risk of hazards, do NOT use
more than the specified power source.
4. Environment
Do not install too warm or too cold place. Recommended
operation temperature is between -5℃ and 50℃
5. Sunlight
Do not point the camera at the sun. CCD can be damaged.
6. Heavy Shock and Vibration
Do not drop the camera or subject it to heavy shock of
vibration.
7. Install on an Unstable Place
Do not place or install this camera on an unstable place,
stand, tripod, bracket or table. That may cause serious injury
to people or damage to appliance.
1. Power(12V)
3. Video Signal
2. No Connection
4. GND
1. Control -
3. Drive +
2. Control +
4. Drive -
11. Damage Requiring service
Unplug the camera from the power source and refer
servicing to qualified service personnel under the following
condition:
Back focus adjustment
1. In case of fixed focus lens
① Loosen the locking ring with L type wrench and set the focus ring
of lens to infinity ( ∞ ).
② Tune the mount ring to get a clear picture( distance from camera
to object is more than 23m) and fasten the locking ring.
2. In case of zoom lens
① Loosen the locking ring with L type wrench and set the lens to the
maximum telephoto position. Then turn the focus ring to focus.
※ In the case of Auto iris lens only, shoot
object or reduce the ambient light so that the aperture is fully open.
② Set the lens to its maximum wide angle position, and set the focus.
③ Repeat step ① and ②, until the difference between focusing
position ① and ② is smallest.
A. If the power-supply cord or plug is damaged.
B. If the camera has been exposed to rain or water.
C. If liquid has been spilled, or objects have fallen into the camera.
D. If the camera does not operate normally by following the operating
instructions. Adjust only those controls that are covered by the
operating instructions as an improper adjustment of other controls
may result in damage and will often require extensive work by a
qualified technician to restore the camera to its normal operation.
E. If the camera has been dropped or the cabinet has been damaged.
F . If the camera exhibits a distinct change in performance.
G. Warranty is not covered in case of natural disaster or wrong
Installation.
a
comparatively dark
④ When the best focusing point in found, fasten the locking ring.
Connection of power supply
Must be checked the power source from the external power supply
before power on.
SPECIFICATIONS
TROUBLESHOOTING
NAMES & FUNCTIONS
OSD MENU
MODEL NAME
Operational
Video Standard
Image Sensor
Total Pixel
VCC-600N
NTSC
VCC-600P
PAL
Before sending the camera out for repair, check the items
below. If the problem persists after checking these items,
contact your service center.
GENERAL SETUP
SYNC
BURST
CONTRAST
SYNC LEVEL adjustment (01…255)
BURST LEVEL adjustment (01…255)
DOWN BUTTON
UP BUTTON
SONY 1/3” Super HAD CCD
410,000 Pixels
380,000 Pixels
470,000 Pixels
440,000 Pixels
CONTRAST LEVEL adjustment
(01…100)
Effective Pixel
Scanning System
Scanning Frequency
Sync System
In case of no image
Is the coaxial cable attached securely?
Are the power and voltage normal?
Has the iris of the lens inside the camera been adjusted correctly?
In case of unclear image
Is the lens in focus?
RETURN
Return to the previous menu.
525 Lines, 2:1 Interlace
15.734kHz(H), 59.94Hz(V)
625 Lines, 2:1 Interlace
15.625kHz(H), 50Hz(V)
(+) BUTTON
ENTER BUTTON
(-) BUTTON
CAMERA SETUP
AE MODE
INTERNAL
More than 50dB
LENS MODE, SHUTTER, AGC, BRIGHTNESS, MAX AGC,
MAX FIELDS, etc.
AWC LOCK, AWC AUTO, ATW, INDOOR, OUTDOOR,
MANUAL, etc.
S/N Ratio
LENS CONNECTOR
0.1lx (F=1.2, 50IRE)
0.001lx (F=1.2, 50IRE, MAX FIELDS x512)
Min. illumination
WB MODE
Horizontal Resolution
Video Output
540 TV Lines
Is the lens dirty?
LENS
BLC MODE
OFF, BLC, WDR, BMB and
VBS 1.0Vp-p / BNC
MANUAL / DC / VSD
Is the monitor adjusted correctly?
※ Dirt of fingerprints on the lens can adversely affect the
images. Gently wipe any dirt or fingerprints off the lens
with a soft cloth or lens cleaning paper and cleaning
fluid (commercially available).
their level, area setting.
Lens Iris Control
Electronic Shutter
AGC
ENTER
PZM SET
Privacy Zone Masking function setting.
Day Night, Night Day mode setting.
Camera ID and Position setting.
1/60 ~ 1/100,000 sec
1/50 ~ 1/100,000 sec
NIGHTSHOT
CAMERA ID
RETURN
OFF - 36dB
VIDEO
CONT
Back Light Compensation
White Balance
OFF / BLC / WDR / BMB
Return to the previous menu.
POWER
DC12V
AWC LOCK / AWC AUTO / ATW / INDOOR / OUTDOOR / MANUAL
Electrical
MEM FUNC. SETUP
DNR MODE
DC
VSD
Digital Noise Reduction mode
Rated Voltage
DC12V ± 2V
1.5W (max)
setting. (OFFLOWHIGH)
Power Consumption
DIMENSIONS
-
+
MD
PIP MODE
QUAD MODE
MD MODE
D.ZOOM
MIRROR
RETURN
Picture-in-picture mode setting.
Quad display mode setting.
Motion Detection mode setting.
Digital Zoom setting. (OFF1.0x…16.0x)
Mirror mode setting. (OFFH.MIRRORV.MIRRORFLIP)
Return to the previous menu.
Mechanical & Environmental
Lens Mount
CS Mount
181g
Weight
Dimensions
61.6[W] x 52.4[H] x 77.8[D]mm
Pantone Color 11C (Gray)
Gray
VIDEO OUTPUT
Front & Rear Color
Body Color
POWER ON LED
Composite Video
Signal Output
This LED is ON
in power ON state.
Operating Temp.
Storage Temp.
-10°C ~ +50°C
SPECIAL SETUP
SHARPNESS
GAMMA
LANGUAGE
RETURN
-20°C ~ +70°C
Sharpness compensation setting. (0~15)
Gamma compensation setting. (0.36~1/USER , 8steps)
OSD Language setting. (ENG, KOR, JPN, CHI1, CHI2)
Return to the previous menu.
Operating Humidity
90% RH (non-condensing)
Lens Type Select Switch
Unit: mm
DC Lens: with no iris amp.
VSD Lens: with iris amp.
DEFAULT SETUP
FACTORY DEFAULT
RETURN
Set to the Factory Default.
Return to the previous menu.
LENS
ENTER
VIDEO
Power Input Terminal and MD Alarm Output
EXIT SETUP
SAVE AND EXIT
EXIT
Honeywell Security Group
Honeywell Co., Ltd.
Address: 5F, Sangam IT Tower, B4 - 4block, 1590
Sangam-dong, Mapo-gu, Seoul 121-835, Republic of
Korea
CONT
POWER
DC12V
DC
VSD
+
-
MD
RETURN
Return to the previous menu.
Printed in Korea
D-100073-001, REV.0
TEL: +82 2 799 6020 / 6395 / 6006
FAX: +82 2 792 9011
E-mail: [email protected]