HumidiPRO™ Digital Humidity Control
H6062A1000
SPECIFICATION DATA
Specifications
Part Number:
1-17/64
(33)
H6062A1000
Supply Voltage:
Amps:
18 to 30 VAC (50/60 Hz)
0.1 A, 2 VA
1-17/64
(32)
Dimensions (See Fig. 1):
Width:
Height:
Length:
Weight:
4-1/2 (114)
3.4 in.
1.27 in.
4.5 in.
0.5 lbs
Shipping Dimensions:
Width:
3-13/32
(86)
4.05 in.
2.55 in.
5.88 in.
0.67 lbs
Height:
Length:
Weight:
Humidity Ranges:
Humidify Control Range:
•
•
20 - 60 % (Automatic mode)
10 - 90 % (Manual mode)
M34947
Dehumidify Control Range:
Fig. 1. Dimensions in inches (mm).
•
•
40 - 80 % (Automatic mode)
10 - 90 % (Manual mode)
TM
Operating Ambient Temperature
Honeywell HumidPRO Frost Index
•
32 to 120 °F (0 to 48.9 °C)
Operating Relative Humidity
5 to 95 %, non-condensing
The table below shows the levels of humidity HumidiPRO delivers
based on the outdoor temperature and window protection settings.
•
Relative Humidity Accuracy:
+/- 5 % RH
Outdoor Temp
For more information call 1-800-468-1502 or visit our
website at customer.honeywell.com.
-10°F
10 10
10 10
10 10
15 15
21 21
29 29
35 39
35 56
35 60
35 60
0°F
10°F
20°F
30°F
40°F
1
2
3
4
5
6
7
8*
9
10
10 10
10 10
14 14
19 19
26 26
34 34
35 46
35 60
35 60
35 60
11 11
15 15
19 19
25 25
32 32
35 39
35 52
35 60
35 60
35 60
17 17
21 21
26 26
32 32
35 38
35 48
35 58
35 60
35 60
35 60
25 25
29 29
34 34
35 39
35 48
35 56
35 60
35 60
35 60
35 60
35 36
35 39
35 46
35 52
35 58
35 60
35 60
35 60
35 60
35 60
Application and Benefits
HumidiPRO offers homeowners convenience and control with
automatic and manual control options as well as optional
advanced features such as expandable range stops and
dehumidification.
HumidiPRO automatically adjusts humidity to protect
windows from condensation in cold weather and can shut off
humidification based on a preset outdoor high temperature limit
(up to 90 °F). The homeowner can set HumidiPRO once at the
beginning of a season and forget it. If needed, the homeowner
can use the humidity boost feature to temporarily raise the
humidity by 5% or 10%.
*Black Numbers show highest humidity allowed when Default RH% (35%) is Selected.
Note: Smaller grey numbers show highest humidity allowed when Maximum RH% (60%) is
selected.
Job Name
Model(s)
H6062A1000
Approval
Service
Qty.
Engineer
Mechanical Contractor
Contractor’s P.O. No.
Representative
Notes
Tag. No.
33-00003-01
Download from Www.Somanuals.com. All Manuals Search And Download.
|