TR21-WS, TR23-WS, TR21-WK,
TR23-WK, WRECVR
The WRECVR receiver and TR21-WS, TR23-WS, TR21-WK,
and TR23-WK are a family of wireless wall modules and
receiver for use with:
SPECIFICATION DATA
FEATURES
—
—
Spyder Unitary Controllers: PUL, PVL, etc.
Excel 10 W7750, W7751, W7752, and W7753
controllers
•
Wall module to Receiver (point to point) wireless kits
can replace any standard wired sensor
Wireless Kits (wall module and receiver) are pre-bound
at the factory for quick installation
Signal Strength LED built into the wall module
Low battery indication
Optional dip switches available to bind any wall
module to any receiver
Approximate 5 year battery life with AA Alkaline
—
—
T7350, T7351, and TB8575 low-voltage SuitePRO™
thermostats
Will not work with TB7220, TB8220 or TB line voltage
thermostats, XL15s, W7762, W7763 or certain other
XL controllers,
•
•
•
•
—
—
Will work with WEBs-AX™ I/O Module products if
using a separate transformer
Compatibility with various other non-Honeywell con-
trollers that accept 10K type2 NTC temperature inputs
•
•
(included), 7.5 year with Lithium
Locking screw discourages tampering and battery
theft.
SPECIFICATIONS
Approvals:
Models:
This device complies with Part 15 of the FCC rules. Operation
is subject to the following two conditions:
TR21-WK: Kit (TR21 and WRECVR bound at factory)
TR23-WK: Kit (TR23 and WRECVR bound at factory)
1) this device may not cause harmful interference, and
2) this device must accept any interference received,
including interference that may cause undesired operation.
Replacements:
TR21-WS: Wireless Temperature sensor
TR23-WS: WirelessTemperature sensor, with Setpoint Knobs
(°F, °C, and Relative [warmer to cooler]), O/R Button, and
LED
General Rules for Installing Wireless
Wall Modules
WRECVR: Receiver
Environmental Ratings:
Communication between the wall module and receiver can be
influenced by a number of factors. Type and thickness of
building materials and the way in which they are oriented in
relation to the wall module and receiver will affect
communication.
•
Wall Module Operating Temperature: 45° to 99°F (7° to
37°C).
•
Receiver Operating Temperature: -40° to 150°F (-40° to
65.5°C).
•
•
Storage Temperature: -40° to 150°F (-40° to 65.5°C).
Operating Humidity: 5% to 95% RH (non-condensing)
Do not place either the wall module or receiver inside metal
cabinets or enclosures.Try to orient the wall module and
receiver so that if they are separated by a wall(s), the direction
of signal travel is as perpendicular to the wall(s) as possible.
This reduces the effective wall thickness.
Accuracy: +/- 1ºF (+/- 0.5ºC) across 12ºC to 30ºC
Setpoint Range for TR23: 56° to 84°F (13° to 29°C)
Accessories: 50007298-001 (pack of 12) medium, cover
plate; 6-7/8 x 5 in. (175 x 127 mm).
When mounting the receiver on a metal duct, stronger
communication is possible if the wall module is on the same
side of the duct so the signal doesn’t need to travel through
the metal duct.
Power:
Receiver Voltage: 20 – 30VAC/DC, 50/60Hz; 24VAC typical
Housing:
Wall Module: UL94-HB, Receiver: UL94-5VA
Reduce as much as possible the amount of metal (ducts, file
cabinets, etc.) between the sensor and the wall module.
Radio Frequency 2.4 GHz (IEEE Std 802.15.4-2003
compliant)
Open Range: 3000 feet
Typical Range: 100 feet
Output power: 16dBm
Receiver power consumption: <1.5VA @ 24VAC
Approximate battery life under normal operating
conditions:
Standard drywall (gypsum board) does not greatly affect
signal strength.
•
•
•
•
•
•
•
5 years with two AA Alkaline batteries (included)
7.5 years with two AA Lithium Batteries
Transmission interval: 30 seconds
Pressing override button or signal strength button will force an
immediate transmission.
63-1332-02
Download from Www.Somanuals.com. All Manuals Search And Download.
|