T
®
OPERATION
Mode:
Test
On-Time
Works: Day Night
Dual Brite™
Motion Sensing
5 Sec
x
x
x
x
x
Auto
1, 5 or 10 Min
To Dawn*
Manual
Coach Light
Accent 3,6 Hr, to Dawn
Models SL-4180/84 - A
* resets to Auto Mode at dawn.
For TEST
Features
• Light comes on when motion is detected.
• Automatically turns light off.
• Dusk Accent lighting.
Set the ON-TIME switch
onthebottomofthe cover
TEST 1 5 10 MIN
plate to TEST.
For AUTO
• Photocell keeps the light off during day-
light hours.
Set ON-TIME switch to 1,
5 or 10 minutes.
This package includes:
TEST 1 5 10 MIN
Mounting screws
and wire
For MANUAL OVERRIDE
Flip the light switch off for
one second then back on.
connectors
Manual override works
when the ON-TIME switch
is in any position.
1 Second OFF
then...
Tail Assembly
(Lantern & Coach)
Manualoverrideonlyworks
at night because daylight
returnsthesensortoAUTO.
Grand
Manor
Candelabra
or
... back on.
Requirements
Mode Switching Summary
• The Light Control requires 120 volts AC.
• If you want to use Manual Override, the
control must be wired through a switch.
• Some codes require installation by a
qualified electrician.
ON-TIME
TEST
Switch at
1, 5 or 10
minutes
Turn
light
AUTO
Flip light
switch
off for 1
second
then on
switch
off for 10
seconds
then
Questions? Call 1-800-858-8501
8:00 AM to 4:45 PM Eastern Time,
weekdays.
MANUAL OVERRIDE
back on*
* Wait one minute for sensor to warm up.
Lo sentimos, pero no podemos contestar
preguntas en español por teléfono.
Dusk Accent Mode
Light comes on half bright for selected time
after dusk (Off, 3 hr., 6 hr., until dawn). If
motion is sensed, the light turns on full bright
for the ON-TIME (1, 5 or 10 minutes) then
returns to dim mode.
© Heath Company
Printed in Hong Kong
595-5578
Download from Www.Somanuals.com. All Manuals Search And Download.
The detector is less sensitive to motion
directly towards it.
Adding Decorative Tail
2. Screw
in exten-
sion bar.
Motion
Motion
3. Add tail
piece and
trim.
1. Remove
decorative nut
from bottom of
fixture.
Sensor
4. Screw
decorative
nut back on.
Least Sensitive
Most Sensitive
❒
Walkthroughthecoverageareanoting
where you are when the lights turn on.
Rotate the sensor head (maximum 0f
45°leftorright)tochangethecoverage
TESTING
❒
❒
Turn on the circuit breaker and light
switch. There is a one minute warm-up
beforethesensorwilldetectmotionprop-
erly.
area.
45°
240°
Switch the on-time to TEST position
and Dual Brite™ switch to the off posi-
tion.
90°
45°
Maximum Sensor
Rotatation
Maximum Aiming
Range
Set the amount of TIME you want the
light to stay on after motion is detected.
OFF
3
6
DUSK TO
DAWN
TEST 1 5 10 MIN
❒
❒
HOUR
Avoid aiming the control at:
OFF
3
6
DUSK TO
DAWN
TEST 1 5 10 MIN
HOUR
• Pools of water or objects that change
temperature rapidly, such as heating
vents and air conditioners. These heat
sources could cause false triggering.
• Areas where pets or traffic may trigger
the control.
• Nearby large, light-colored objects re-
flecting daylight may trigger the shut-off
feature. Do not point other lights at the
Set the amount of time after dusk you
want the lights on accent level.
SPECIFICATIONS
Range . . . . . . . . . . . Upto30feet(variesduring
daylight hours).
Sensing Angle . . . . . Up to 150°, 240° aimable
Electrical Load. . . . . (3) 60 W. candelabra,
400W (3.3 A.) total
sensor.
150°
Power Requirements 120 VAC, 60 Hz
Operating Modes. . . TEST, AUTO and
MANUAL OVERRIDE
Time Delay . . . . . . . 1 , 5, 10 minutes
Accent timer . . . . . . Off, 3, 6 Hrs, to dawn
6 ft.
Sensitivity . . . . . . . . Adjustable
30 ft.
The Heath Company reserves the right to discontinue
products and to change specifications at any time
without incurring any obligation to incorporate new
features in products previously sold.
Maximum
Range
Maximum
Coverage Angle
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE
If you experience a problem, follow this guide. If the problem persists, call the
assistance at 1-800-858-8501 8:00 AM and 4:45 PM EST weekdays.
Lo sentimos, pero no podemos contestar preguntas en español por teléfono.
POSSIBLE CAUSE
SYMPTOM
POSSIBLE CAUSE
SYMPTOM
1. Light switch is turned off.
2. Bulbislooseorburnedout.
3. Fuse is blown or circuit
breaker is turned off.
4. Daylightturn-offisineffect
(recheck after dark).
5. Incorrect circuit wiring, if
this is a new installation.
6. Re-aimthesensortocover
desired area.
Light will not
come on.
1. The sensor is pointed at
nearby objects that cause
heat to trigger the sensor.
(Aimthesensorawayfrom
nearby objects.)
2. The sensor is pointed
toward a heat source like
an air vent, dryer vent, or
brightly-painted heat-
reflectivesurface.(Re-aim
sensor.)
Light stays on
continuously.
Light comes
on in day-
light.
1. Light Control may be in-
stalled in a relatively dark
location.
2. Light Control is in Test. (Set
control switch to an ON-
1. Heatbeingreflectedfrom
other objects may be
affectingthesensor.(Re-
aim sensor.)
2. LightControlisintheTest
mode and warming up.
(Flashingisnormalunder
these conditions).
Light flashes
on and off.
TIME position.)
1. Light Control may be sens-
Light comes
on for no
apparent
reason.
ingsmallanimalsorautomo-
bile traffic (re-aim sensor).
2. Sensitivity is set too high.
(Reduce sensitivity.)
YOUR HEATH ZENITH FIVE YEAR LIMITED WARRANTY
This is a “Limited Warranty” as defined in the U.S. Consumer Product Warranty and Federal Trade
CommissionImprovementAct. Thiswarrantygivesyouspecificlegalrights, andyoumayalsohave
other rights which vary from state to state.
For a period of five years from the date of purchase, any malfunction caused by factory defective
partsorworkmanshipwillbecorrectedatnochargetoyou. Lightbulbsarenotcovered.Toobtain
a refund or a replacement, return the product to the place of purchase.
Not Covered — Repair service, adjustment and calibration due to misuse, abuse or negligence,
light bulbs and other expendable items are not covered by this warranty. Unauthorized service or
modification of the product or of any furnished component will void this warranty in its entirety. This
warranty does not include reimbursement for inconvenience, installation, set-up time, loss of use,
or unauthorized service.
ThiswarrantycoversonlyHeathZenithassembledproductsandisnotextendedtootherequipment
and components that a customer uses in conjunction with our products.
SUCH REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND
THERE SHALL BE NO LIABILITY ON THE PART OF HEATH FOR ANY SPECIAL, INDIRECT,
INCIDENTAL, OR CONSEQUENTIAL DAMAGES, INCLUDING BUT NOT LIMITED TO ANY
LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEEABLE. Some states do not
allow the exclusion or limitation of incidental or consequential damages, so the above limitation or
exclusion may not apply to you.
Download from Www.Somanuals.com. All Manuals Search And Download.
|