50336/50337.instructions 3/26/01 11:29 AM Page 1  
• Remove remaining 3-way switch from the junction box.  
INSTALLING THE SWITCH  
3-Way With One Motion Sensing Switch  
• Add the jumper wire to the common lug and to either one of the two switched lugs. If you're not sure which  
lug is common, install the jumper on any two of the three wires, and test the jumper as explained on the next  
page.  
Test for correct common wire connection:  
Re-install the switch.  
WARNING: Turn power off at the circuit breaker before wiring.  
3-Way Motion  
Turn the circuit  
breaker back on.  
Note: a "3-way" circuit controls lights from two sepa-  
Sensing Switch  
rate switches. If you want to use this product in a sin-  
gle switch circuit or if you want to install more than one  
motion sensing wall switch, see page 6  
• Remove the decorative coverplate (secured by two  
screws).  
The 3-Way Motion Sensing Switch (MSS) detects motion to turn on  
lights for an adjustable amount of time. A built-in photo cell can be set  
to keep lights off when the lights aren't needed. The unit has excellent  
sensitivity and a wide 1500 detection range. It can be used with incan-  
descent lighting as well as rapid start fluorescent lighting.  
Common  
Switch Lug  
The switch may  
indicate the  
Leaving the jumpered switch in one position,  
flip the other 3-way switch on and off.  
• Remove Control Cover. (Press in with screwdriver.  
Swing out cover to remove.)  
COMMON  
common  
Hot Wire  
• Choose which switch will be replaced and remove it.  
• For easier re-wiring later, mark the house wiring with  
tape indicating where the wire had been connected.  
The MSS can be used to replace either a 3-way wall switch or a  
single pole switch. Some codes require installation by a qualified elec-  
trician.  
OR  
OFF AUTO  
ON  
Features include:  
Color of screw  
may be different  
for the common  
Lights  
turn on  
and off.  
Jumper is  
correct. Go  
to next page.  
• 1500 motion detection angle  
Jumper  
Yes  
• Adjustable on-time from 5 sec. to 20 min.  
• Adjustable photocell  
• Works with incandescent and rapid start fluorescent lighting  
• Works with motors up to 1/8 hp.  
• Slide switch selectable OFF, ON AND AUTO modes.  
No  
Common Switch Lug  
Hot Wire  
Included are: • The sensor switch • Cover plate • 4 wire connectors • 2 large screws • 2 small screws.  
To Brown wire  
of MSS  
(note Color)  
Hot Wire  
Move one end of the jumper  
wire to the previously  
Flip the switch with the  
jumper wire to the  
other position.  
To Red wire  
of MSS  
(note color)  
INSTALLATION  
30'  
unconnected terminal.  
WARNING: For indoor use only.  
SELECT A LOCATION  
Flip the unjumpered switch  
on and off.  
Remove the jumpered  
switch from the  
junction box.  
3-Way Switch Wiring Diagram  
NEW APPLICATION  
Choose a location where the motion sensor has a clear view of  
the entire area where occupant motion may occur.  
15'  
RETROFIT APPLICATION  
Motion sensing switch will replace existing wall switch. Use only  
where the existing switch location provides a clear view of the  
occupied area.  
0'  
Typical Plan View of Coverage  
Turn the power  
off at the  
circuit breaker.  
Lights  
turn on  
and off.  
Jumper is  
Yes  
No  
correct. Go  
GENERAL APPLICATION INFORMATION  
The detector is more sensitive to motion across the front of the sensor than to motion towards the sensor.  
to next page.  
Questions? Call 1-800-435-4448 8:00 AM to 6:30 PM Eastern Time, weekdays  
The detector senses heat in motion and possible heat sources that change temperature quickly. Therefore, to  
avoid false triggering, avoid placing the sensor where it will be aimed at air conditioners, heaters, and other  
sources of heat or cold.  
598-1107-01  
- 4 -  
- 2 -  
- 3 -  
• Connect the 3-Way Motion Sensing Switch as shown in the diagram below:  
Single Switch Installation  
TROUBLESHOOTING  
ADJUSTMENTS  
HOT  
Replace  
switch with MSS  
If you have a problem with your Wall Switch, first follow this guide. If the problem persists, call the  
customer service hotline at 1-800-435-4448 between 8:00 AM and 6:30 PM ET weekdays.  
• For single switch installations,  
TIME  
LIGHT LEVEL  
connect the wall switch as shown  
here.  
LOAD  
SYMPTOM  
POSSIBLE CAUSE  
SYMPTOM  
POSSIBLE CAUSE  
Hot Wire  
There are  
6
preset selections for the  
The sensor can be prevented from turning on lights  
when there is already enough light in the room. Use a  
small phillips screw driver to set the light level using this  
diagram as a guide. In the fully clock-  
Black  
amount of time the lights stay on: Test (5  
seconds), 1, 5, 10, 15, and 20 minutes. Use  
a small, phillips screw driver to adjust the  
TIME control (see Figure 4). Turn the TIME  
control until it “snaps” into the desired time  
position.  
Brown  
Light does not come 1. Circuit breaker or fuse is  
Light does not turn  
off.  
1. Incorrect wiring.  
2. MODE switch is set to  
ON instead of AUTO.  
3. Motion is still present.  
4. Delay set by TIME  
control has not  
¨
on in the AUTO  
mode.  
turned off.  
2. If the lamp being controlled  
has another switch, it may  
be turned off.  
3. Bulb is defective.  
4. LIGHT control is set too far  
Add  
Jumper  
Wire  
Jumpered Wire  
wise position, the sensor turns on  
lights even in full daylight. In the fully  
counter-clockwise position, the sen-  
sor only turns on lights when the sur-  
OFF AUTO  
ON  
Hot Wire  
Green ground wire to  
junction box screw or  
grounding wire  
expired.  
BLACK  
rounding light level is very low.  
OFF AUTO  
ON  
Dark (low light level)  
toward the DARK position.  
MODE switch is set to OFF  
instead of AUTO.  
Any Light Level  
1. Heating or cooling ob-  
jects (such as air  
Light comes on for  
no reason in the Auto  
mode.  
Green ground wire to  
junction box screw or  
grounding wire  
5.  
To adjust the photocell:  
+
Red  
• When the light in the room is at the  
level you want the lights to turn on,  
set the switch to the AUTO position.  
• Put the TIME control to the 5 sec-  
ond position.  
• Put the LIGHT control to the mini-  
mum dark (fully counter-clockwise)  
position.  
• Wait for the lights to turn off.  
Turn the LIGHT adjustment clock-  
wise in very small steps and wait 2  
seconds before moving your hand  
in front of the sensor. Repeat until  
the lights controlled by the sensor  
come on. The light will now come  
on when the light level is at or below  
the present level and motion is  
detected.  
vents, appliances, or  
drafts through the wall  
box) are causing false  
triggering.  
2. Switch on the sensor  
has been turned off  
and back on.  
5
10  
Red & Brown  
6. Poor connection.  
1
15  
1. Motion has stopped in the  
room.  
TIME control is set for too  
short a delay.  
3-Way with Two Motion Sensors  
If you want to have motion sensors at both 3-way switches, connect them as shown below. The minimum  
Lights do not stay  
on in the Auto mode.  
Test  
20  
3-Way Motion Sensor Wiring Diagram  
T I M E  
L I G H T  
2.  
wattage may increase to 100 W for fluorescent and 50 W for incandescent lighting.  
• Mount the MSS into the junction box with the two junction box screws.  
• Turn the circuit breaker back on.  
• Preset the controls: Time to min. (fully CCW), Photo Adjustment fully clockwise. Cover the lens with masking  
tape.  
• With the motion sensor in the "ON" position, turn the remote switch on and off several times. Go to step 1, 2,  
or 3, depending on results.  
5 Seconds  
20 Minutes  
3. There was a momen-  
tary power interrup-  
tion. The light will turn  
off automatically when  
the "on" time expires.  
Common Switch Lug  
HOT  
HOT  
SPECIFICATIONS  
Electrical input................................................................................................................................120V, 60 Hz  
Fluorescent Load...........................................................(2) 30 Watt minimum 400 Watt maximum Rapid Start  
Motor Load.............................................................................................................................1/8 HP maximum  
Incandescent.........................................................................................................................500W at 120V AC  
On-Time..........................................................................................Adjustable approximately 5 sec. to 20 min.  
Photocell Sensor.......................................................................................From dull daylight to less than 1 FC.  
Coverage...............................................................................up to 15 ft. at 1500, up to 30 ft. in front of the sensor  
WARNING: Shut off all power at fuse box or circuit breaker before beginning installation.  
Exchange  
3-Way  
Switch  
3-Way  
Switch  
Test again.  
Go to 2 or 3.  
If light does  
not turn on:  
Red & Black  
wires on  
1.  
2.  
3.  
Complete Installation  
• Replace control panel cover and install the decorative wall plate. In installations where the GE motion sensor  
switch is combined with other switches or outlets on an expanded box, a combination wall plate will need to  
be purchased. Various combination wall plates are available at Home Centers and Electrical Supply Stores.  
MSS Control  
Existing Wiring Diagram  
Exchange  
Red & Brown  
wires on  
If light turns  
on in only one  
position of  
HOT  
Test again.  
Go to 1 or 3.  
Red & Brown  
WARNING  
Red &  
Brown  
• Slide the switch a couple of times to make sure it operates freely.  
remote switch:  
MSS Control  
Risk of electric shock  
• Shut off power at fuse box or  
circuit breaker before installation  
• Use indoors only  
If light turns  
on with  
remote switch  
in either  
position:  
Set sensor to "AUTO". Wait for the  
unit to warm up (up to 1 min.). If the  
remote switch can turn the lights on,  
it's OK. Otherwise:  
USE  
HOT  
OFF AUTO  
ON  
OFF AUTO  
ON  
Black  
Black  
MODE Selection Switch  
Moving the switch selects one of three modes of operation: OFF, AUTO, ON  
Risk of fire  
• Do not exceed electrical ratings  
Green ground wire to  
junction box screw or  
grounding wire  
OFF: Lights stay off.  
Exchange Red & Brown wires  
on MSS Control. Remove the  
tape. Go to the next page.  
AUTO: Lights come on for time set when motion is detected and the light level is below the set level or when  
3-way switch is manually switched.  
Dual 3-Way Motion Sensor Wiring Diagram  
Res. #8143555  
ON: Lights stay on continuously. Flipping 3-way switch has no effect.  
- 7 -  
- 6 -  
- 8 -  
- 5 -  
Download from Www.Somanuals.com. All Manuals Search And Download.  

GPX Refrigerator 1409 0319 10 User Manual
Graco Inc Pressure Washer 308 507 User Manual
Groupe SEB USA T FAL Iron FV9330 User Manual
Hans Grohe Plumbing Product 06041000 User Manual
Hasbro Robotics 81057 Asst User Manual
Honeywell Automobile HCM 3060 User Manual
HP Hewlett Packard Computer Drive X510 User Manual
HP Hewlett Packard Welder storage works User Manual
Huffy Fitness Equipment M790054 User Manual
Husqvarna Lawn Mower 11C User Manual