OPERATION
Mode:
Test
Auto
On-Time:
5 Sec
Works: Day Night
x
x
x
x
Motion Sensor
1, 5, 20 min.
Until Dawn*
Manual
Light Control with
Protective Lamp
Shields
Model CB-2011
* resets to Auto Mode at dawn.
Note:When first turned on wait about 1 1/2 minutes for
the circuitry to calibrate.
TEST
Put ON-TIME switch on the sensor
bottom to TEST.
ON-TIME
Features
TEST 1 5 20
• Turns on lighting when motion is detected.
• Automatically turns lighting off.
• Photocell keeps the lighting off during daylight hours.
AUTO
ON-TIME
Put the ON-TIME switch in the 1, 5,
or 20 minute position.
This package includes:
TEST 1 5 20
Lamp
Holders
MANUAL MODE
Mounting Strap
Manual mode only works at night
because daylight returns the sensor
to AUTO.
Rubber Plug
Flipthelightswitchoffforonesecond
thenbackontotogglebetweenAUTO
and MANUAL MODE.
1 Second OFF
then...
Cover
Plate
Sensor
Plastic Hanger
Gasket
Light Control
Manual mode works only with the
ON-TIME switch in the 1, 5, or 20
position.
... back on.
Mounting Bolt
Mode Switching Summary
2 Wire
Connectors
6 Screws
(3 sizes included)
TEST
Move ON-TIME Switch to
1, 5 or 20 minutes
AUTO
Flip light switch off for
one second then back
on*
2 PAR Lamps
MANUAL MODE
Requirements
• The Light Control requires 120-volts AC.
• If you want to use the Manual Mode, the control must
be wired through a switch.
• Some codes require installation by a qualified
electrician.
* If you get confused while switching modes, turn the
power off for one minute, then back on. After the
calibration time the control will be in the AUTO mode.
• This product is intended for use with the enclosed
gasket and with a junction box marked for use in wet
locations.
© 2003 DESA Specialty Products™
598-1111-01
Download from Www.Somanuals.com. All Manuals Search And Download.
❒
❒
Loosen the clamp screw in
thesensorballjointandgen-
tly rotate the sensor.
Clamp
Screw
TEST AND ADJUSTMENT
❒
Turn on the circuit breaker and light switch.
1
Walk through the coverage
area noting where you are
whenthelightsturnon.Move
the sensor head up, down,
or sideways to change the
coverage area. Keep the
sensor at least 1" (2.5 cm)
away from the lamps.
NOTE: Sensor has a 1 /2 minute warm up period
before it will detect motion. When first turned
onorwhenswitchingmodeswait11/2 minutes.
Ball
Joint
❒
Turn the RANGE control to the mid position and the
ON-TIME control to the TEST position.
Aim Sensor
Down for Short
Coverage
❒
❒
❒
Adjust the RANGE as
needed.RANGEsettoohigh
MAX
may
increase
false
ON - TIME
triggering.
Secure the sensor head's
aim by tightening the
clamp screw. Do not over-
tighten the screw.
MIN
Aim Sensor
Higher for Long
Coverage
TEST 1
5
2 0
RANGE
MINUTES
Bottom of Sensor
Set the amount of TIME you want the lights to stay
on after motion is detected (1, 5, or 20 minutes).
Avoid aiming the sensor at:
• Objects that change temperature rapidly, such as
heating vents and air conditioners. These heat
sources could cause false triggering.
SPECIFICATIONS
• Areas where pets or traffic may trigger the control.
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.
(30.5 m) with Range Boost.
• Nearby large, light-colored objects reflecting light
may trigger the shut-off feature. Do not point other
lights at the sensor.
[varies with surrounding
temperature]
Sensing Angle . . . . . . Up to 240°
Electrical Load. . . . . . Up to 300 Watts Maximum In-
candescent [Up to 150 Watts
240°
Maximum each lamp holder].
8 ft.
(2.4 m)
Power Requirements. 120 VAC, 60 Hz
Operating Modes. . . . TEST, AUTO and MANUAL
MODE
70 ft.
(21 m) (30.5 m)
Boosted
100 ft.
Time Delay . . . . . . . . 1 , 5, 20 minutes
DESA Specialty Products™ reserves the right to
discontinue products and to change specifications at
any time without incurring any obligation to incorporate
new features in products previously sold.
Maximum Range
Maximum
Coverage Angle
The detector is less sensitive to motion directly towards it.
Motion
Motion
Least Sensitive
598-1111-01
Sensor
Most Sensitive
3
Download from Www.Somanuals.com. All Manuals Search And Download.
TROUBLESHOOTING GUIDE
SYMPTOM
POSSIBLE CAUSE
SYMPTOM
POSSIBLE CAUSE
Lights will
not come
on.
1. Light switch is turned off.
2. Flood light is loose or burned out.
3. Fuseisblownorcircuitbreakeristurned
off.
4. Daylight turnoff is in effect (recheck
after dark).
5. Incorrect circuit wiring, if this is a new
installation.
6. Re-aim the sensor to cover desired
area.
Lights stay
on continu-
ously.
1. A flood lamp is positioned too close to
the sensor or pointed at nearby ob-
jects that cause heat to trigger the
sensor. (Reposition the lamp away
from the sensor or nearby objects.)
2. Light Control is pointed toward a heat
source like an air vent, dryer vent, or
brightly-paintedheat-reflectivesurface.
(Reposition sensor. Reduce Range.)
3. Light Control is in Manual Mode.
(Switch to Auto.)
Lights come 1. Light Control may be installed in a
on in
daylight.
relatively dark location.
2. Light Control is in Test. (Set control
switch to an ON-TIME position.)
Lights flash
on and off.
1. Heat or light from the lamps may be
turning the Light Control on and off. (Re-
positionthelampsawayfromthesensor.)
2. Heat being reflected from other ob-
jects may be affecting the sensor.
(Reposition sensor.)
3. Light Control is in the Test mode and
warming up. (Flashing is normal un-
der these conditions. Turn Boost off.)
Lights come 1. Light Control may be sensing small ani-
on for no
apparent
reason.
malsorautomobiletraffic(re-aimsensor).
2. Range is set too high. (Reduce Range
setting.)
Lights flash
once, then
stay off in
1. Sensor is detecting its own lights.(Re-
position lamps to keep area below the
sensor relatively dark.)
Manual Mode.
TECHNICAL SERVICE
(Do Not Send Products)
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the
problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:
DESA Specialty Products™
P.O. Box 90004, Bowling Green, KY 42102-9004
ATTN: Technical Service Specialty Products
* If contacting Technical Service, please have the following information available: Model Number, Date of
Purchase, and Place of Purchase.
No Service Parts Available for this Product
15 YEAR LIMITED WARRANTY
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state
or province to province.
Foraperiodoffifteenyearsfromthedateofpurchase, anymalfunctioncausedbyfactorydefectivepartsorworkmanshipwillbecorrected
at no charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase.
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items
are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty
initsentirety.Thiswarrantydoesnotincludereimbursementforinconvenience,installation,setuptime,lossofuse,orunauthorizedservice.
This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and
components that a customer uses in conjunction with our products.
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY
WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY
PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES.
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY
ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL
DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEE-
ABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you. Retain receipt for warranty claims.
598-1111-01
4
Download from Www.Somanuals.com. All Manuals Search And Download.
|