Heath Zenith Home Security System CB 2011 User Manual

OPERATION  
Mode:  
Test  
Auto  
On-Time:  
5 Sec  
Works: Day Night  
x
x
x
x
Motion Sensor  
1, 5, 20 min.  
Until Dawn*  
Manual  
Light Control with  
Protective Lamp  
Shields  
Model CB-2011  
* resets to Auto Mode at dawn.  
Note:When first turned on wait about 1 1/2 minutes for  
the circuitry to calibrate.  
TEST  
Put ON-TIME switch on the sensor  
bottom to TEST.  
ON-TIME  
Features  
TEST 1 5 20  
• Turns on lighting when motion is detected.  
• Automatically turns lighting off.  
• Photocell keeps the lighting off during daylight hours.  
AUTO  
ON-TIME  
Put the ON-TIME switch in the 1, 5,  
or 20 minute position.  
This package includes:  
TEST 1 5 20  
Lamp  
Holders  
MANUAL MODE  
Mounting Strap  
Manual mode only works at night  
because daylight returns the sensor  
to AUTO.  
Rubber Plug  
Flipthelightswitchoffforonesecond  
thenbackontotogglebetweenAUTO  
and MANUAL MODE.  
1 Second OFF  
then...  
Cover  
Plate  
Sensor  
Plastic Hanger  
Gasket  
Light Control  
Manual mode works only with the  
ON-TIME switch in the 1, 5, or 20  
position.  
... back on.  
Mounting Bolt  
Mode Switching Summary  
2 Wire  
Connectors  
6 Screws  
(3 sizes included)  
TEST  
Move ON-TIME Switch to  
1, 5 or 20 minutes  
AUTO  
Flip light switch off for  
one second then back  
on*  
2 PAR Lamps  
MANUAL MODE  
Requirements  
• The Light Control requires 120-volts AC.  
• If you want to use the Manual Mode, the control must  
be wired through a switch.  
Some codes require installation by a qualified  
electrician.  
* If you get confused while switching modes, turn the  
power off for one minute, then back on. After the  
calibration time the control will be in the AUTO mode.  
• This product is intended for use with the enclosed  
gasket and with a junction box marked for use in wet  
locations.  
© 2003 DESA Specialty Products™  
598-1111-01  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Loosen the clamp screw in  
thesensorballjointandgen-  
tly rotate the sensor.  
Clamp  
Screw  
TEST AND ADJUSTMENT  
Turn on the circuit breaker and light switch.  
1
Walk through the coverage  
area noting where you are  
whenthelightsturnon.Move  
the sensor head up, down,  
or sideways to change the  
coverage area. Keep the  
sensor at least 1" (2.5 cm)  
away from the lamps.  
NOTE: Sensor has a 1 /2 minute warm up period  
before it will detect motion. When first turned  
onorwhenswitchingmodeswait11/2 minutes.  
Ball  
Joint  
Turn the RANGE control to the mid position and the  
ON-TIME control to the TEST position.  
Aim Sensor  
Down for Short  
Coverage  
Adjust the RANGE as  
needed.RANGEsettoohigh  
MAX  
may  
increase  
false  
ON - TIME  
triggering.  
Secure the sensor head's  
aim by tightening the  
clamp screw. Do not over-  
tighten the screw.  
MIN  
Aim Sensor  
Higher for Long  
Coverage  
TEST 1  
5
2 0  
RANGE  
MINUTES  
Bottom of Sensor  
Set the amount of TIME you want the lights to stay  
on after motion is detected (1, 5, or 20 minutes).  
Avoid aiming the sensor at:  
• Objects that change temperature rapidly, such as  
heating vents and air conditioners. These heat  
sources could cause false triggering.  
SPECIFICATIONS  
• Areas where pets or traffic may trigger the control.  
Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft.  
(30.5 m) with Range Boost.  
Nearby large, light-colored objects reflecting light  
may trigger the shut-off feature. Do not point other  
lights at the sensor.  
[varies with surrounding  
temperature]  
Sensing Angle . . . . . . Up to 240°  
Electrical Load. . . . . . Up to 300 Watts Maximum In-  
candescent [Up to 150 Watts  
240°  
Maximum each lamp holder].  
8 ft.  
(2.4 m)  
Power Requirements. 120 VAC, 60 Hz  
Operating Modes. . . . TEST, AUTO and MANUAL  
MODE  
70 ft.  
(21 m) (30.5 m)  
Boosted  
100 ft.  
Time Delay . . . . . . . . 1 , 5, 20 minutes  
DESA Specialty Products™ reserves the right to  
discontinue products and to change specifications at  
any time without incurring any obligation to incorporate  
new features in products previously sold.  
Maximum Range  
Maximum  
Coverage Angle  
The detector is less sensitive to motion directly towards it.  
Motion  
Motion  
Least Sensitive  
598-1111-01  
Sensor  
Most Sensitive  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLESHOOTING GUIDE  
SYMPTOM  
POSSIBLE CAUSE  
SYMPTOM  
POSSIBLE CAUSE  
Lights will  
not come  
on.  
1. Light switch is turned off.  
2. Flood light is loose or burned out.  
3. Fuseisblownorcircuitbreakeristurned  
off.  
4. Daylight turnoff is in effect (recheck  
after dark).  
5. Incorrect circuit wiring, if this is a new  
installation.  
6. Re-aim the sensor to cover desired  
area.  
Lights stay  
on continu-  
ously.  
1. A flood lamp is positioned too close to  
the sensor or pointed at nearby ob-  
jects that cause heat to trigger the  
sensor. (Reposition the lamp away  
from the sensor or nearby objects.)  
2. Light Control is pointed toward a heat  
source like an air vent, dryer vent, or  
brightly-paintedheat-reflectivesurface.  
(Reposition sensor. Reduce Range.)  
3. Light Control is in Manual Mode.  
(Switch to Auto.)  
Lights come 1. Light Control may be installed in a  
on in  
daylight.  
relatively dark location.  
2. Light Control is in Test. (Set control  
switch to an ON-TIME position.)  
Lights flash  
on and off.  
1. Heat or light from the lamps may be  
turning the Light Control on and off. (Re-  
positionthelampsawayfromthesensor.)  
2. Heat being reflected from other ob-  
jects may be affecting the sensor.  
(Reposition sensor.)  
3. Light Control is in the Test mode and  
warming up. (Flashing is normal un-  
der these conditions. Turn Boost off.)  
Lights come 1. Light Control may be sensing small ani-  
on for no  
apparent  
reason.  
malsorautomobiletraffic(re-aimsensor).  
2. Range is set too high. (Reduce Range  
setting.)  
Lights flash  
once, then  
stay off in  
1. Sensor is detecting its own lights.(Re-  
position lamps to keep area below the  
sensor relatively dark.)  
Manual Mode.  
TECHNICAL SERVICE  
(Do Not Send Products)  
If you experience a problem, follow this guide. You may also want to visit our Web site at: www.desatech.com. If the  
problem persists, call* for assistance at 1-800-858-8501, 7:30 AM to 4:30 PM CST (M-F). You may also write* to:  
DESA Specialty Products™  
P.O. Box 90004, Bowling Green, KY 42102-9004  
ATTN: Technical Service Specialty Products  
* If contacting Technical Service, please have the following information available: Model Number, Date of  
Purchase, and Place of Purchase.  
No Service Parts Available for this Product  
15 YEAR LIMITED WARRANTY  
This is a “Limited Warranty” which gives you specific legal rights. You may also have other rights which vary from state to state  
or province to province.  
Foraperiodoffifteenyearsfromthedateofpurchase, anymalfunctioncausedbyfactorydefectivepartsorworkmanshipwillbecorrected  
at no charge to you. Light bulbs are not covered. To obtain a refund or a replacement, return the product to the place of purchase.  
Not Covered - Repair service, adjustment and calibration due to misuse, abuse or negligence, light bulbs and other expendable items  
are not covered by this warranty. Unauthorized service or modification of the product or of any furnished component will void this warranty  
initsentirety.Thiswarrantydoesnotincludereimbursementforinconvenience,installation,setuptime,lossofuse,orunauthorizedservice.  
This warranty covers only DESA Specialty Products™ assembled products and is not extended to other equipment and  
components that a customer uses in conjunction with our products.  
THIS WARRANTY IS EXPRESSLY IN LIEU OF ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING ANY  
WARRANTY, REPRESENTATION OR CONDITION OF MERCHANT ABILITY OR THAT THE PRODUCTS ARE FIT FOR ANY  
PARTICULAR PURPOSE OR USE, AND SPECIFICALLY IN LIEU OF ALL SPECIAL, INDIRECT, INCIDENTAL, OR  
CONSEQUENTIAL DAMAGES.  
REPAIR OR REPLACEMENT SHALL BE THE SOLE REMEDY OF THE CUSTOMER AND THERE SHALL BE NO LIABILITY  
ON THE PART OF DESA SPECIALTY PRODUCTS™ FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL  
DAMAGES, INCLUDING BUT NOT LIMITED TO ANY LOSS OF BUSINESS OR PROFITS, WHETHER OR NOT FORESEE-  
ABLE. Some states or provinces do not allow the exclusion or limitation of incidental or consequential damages, so the above  
limitation or exclusion may not apply to you. Retain receipt for warranty claims.  
598-1111-01  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Saw G8622 User Manual
Haier Water Heater QBJ1 130A58E User Manual
Hamilton Beach Coffee Grinder 840107900 User Manual
HANNspree Flat Panel Television MAC 001056 User Manual
Harman Kardon Stereo Amplifier TA260 User Manual
Hotpoint Cooktop CIO 640 DD Z User Manual
HP Hewlett Packard Network Router 3577A User Manual
Hunter Fan Outdoor Ceiling Fan 21100 User Manual
Husqvarna Automobile HUV4420 User Manual
Impex Fitness Equipment SB 670 User Manual