Model VA
Reach In Unit Cooler
APPLICATION
The Model VA unit cooler is a deluxe unit designed for use in
small reach-ins, back bar and under counter refrigerators, and
many other applications where a small, compact unit is
required. The thermal expansion valve mounts inside the unit.
The unit can be mounted from the ceiling or off the back wall
or end walls.
• Internal junction box for electrical connection.
• Pigtail leads in junction box.
• Motors are thermally protected and permanently lubricated.
FEATURES
• Textured aluminum cabinet.
• Molded Lexan® fan guard.
• Optional corrosion-resistant coated coil available (VAK) for
optimum protection in corrosive environments.
• UL listed for the United States and Canada; UL classified to
NSF standards.
• Improved drain pan overlaps coil surface to catch all
condensate.
• Stainless steel screws - prevent rust streaks.
• Plate-type aluminum fins with full collars on expanded
copper tubes.
• Expansion valve mounts inside cabinet.
Performance/Electrical Data
MOTOR DATA
115/1/60
QTY TOTAL FLA TOTAL FLA INLET
CONNECTIONS (INCHES) APPROX.
SHIP WT.
(LBS.)
MODEL
BTUH
10˚F TD CFM
208-230/1/60
COIL
VA
06
08
12
SUCTION DRAIN
600
800
135
130
265
245
1
1
1
2
0.8
0.8
1.6
1.0
0.4
0.4
0.8
0.5
1/2FN
1/2FN
1/2FN
1/2FN
3/8ID
3/8ID
3/8ID
1/2ID
1/2OD
1/2OD
1/2OD
1/2OD
9
9
14
11
1200
1700
17
DIMENSIONAL DATA
MODEL
DIMENSIONS (INCHES)
VA
06
08
12
A
B
C
D
—
—
—
9
E
—
—
—
21/2
F
H
J
K
W
45/16
45/16
41/2
51/4
131/4
131/4
183/4
143/4
45/16
45/16
55/16
51/4
33/8
33/8
33/8
4
67/8
67/8
8
51/4
51/4
47/8
613/16
81/8
81/8
81/8
121/2
121/4
18
17
93/4
101/2
14
NOMENCLATURE
VA (K) 08 B E
VA = Reach-In
Unit Cooler
K = Coated Coil
(Optional)
Size
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Model C
High Profile Reach In Unit Cooler
APPLICATION
Here is the ideal unit for refrigerated reach-ins. It mounts to
the top of the refrigerator and discharges cold air against the
back wall. With this air flow pattern, the air is not blasted on
the product but is diffused along the back wall and then
gently drawn across the product as it returns to the unit. Thus
uniform temperatures are maintained throughout the
refrigerator. In addition, door sweating and refrigeration loss
due to door opening is greatly reduced because the air is not
discharged against the doors.
FEATURES
• Textured aluminum cabinet.
• Molded Lexan® fan guard.
• Drain fitting at 45-degree angle so drain can be run through
bottom or back of refrigerator.
• Full collar aluminum fins on expanded copper tubes.
• Internal junction box with pigtail leads for electrical
connection.
• Aluminum hangers automatically space the unit the correct
distance from the back wall.
• Motors are thermally protected and permanently lubricated.
• Stainless steel screws - prevent rust streaks.
• Room for expansion valve inside unit.
• UL listed for the United States and Canada; UL classified to
NSF standards.
• Knockouts in sides and top plus openings in rear provide
maximum flexibility for electrical connection.
• Optional corrosion-resistant coated coil available (Model CK)
for optimum protection in corrosive environments.
Performance/Electrical Data
MOTOR DATA
115/1/60
QTY TOTAL FLA TOTAL FLA INLET
CONNECTIONS (INCHES) APPROX.
SHIP WT.
MODEL
BTUH
10˚F TD CFM
208-230/1/60
COIL
C
13
17
23
30
†43
SUCTION DRAIN
(LBS.)
16
17
1300
1700
2300
3000
4300
235
250
265
480
520
1
1
1
2
2
1.0
1.0
1.0
2.0
2.0
0.5
0.5
0.5
1.0
1.0
1/2FN
1/2FN
1/2FN
1/2FN
1/2FN
3/8ID
3/8ID
3/8ID
1/2ID
1/2ID
1/2OD
1/2OD
1/2OD
1/2OD
1/2OD
22
27
40
†Size 43 uses external equalized expansion valve.
DIMENSIONAL DATA
MODEL
DIMENSIONS (INCHES)
C
13
17
23
30
43
A
B
C
D
13/8
13/8
7/8
1
W
125/8
155/8
211/8
261/8
365/16
123/8
123/8
123/8
123/8
----
117/16
147/16
211/16
2513/16
----
141/4
171/4
223/4
273/4
38
----
NOMENCLATURE
C (K) 43 B F
C = High Profile
Unit Cooler
Vintage
A = 115/1/60
B = 208-230/1/60
K = Coated Coil
(Optional)
Size
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Model BTO
Twin Flow Reach In Unit Cooler
APPLICATION
Twin flow unit coolers are ideal for temperatures of 35°F and
higher. Box temperatures are kept more constant throughout
and fresh products last longer. Seven sizes are available with
BTUH from 900 to 5,500 at 10° TD. Larger BTO sizes are
suitable for large reach-in and small step-in or walk-in
coolers.
FEATURES
• Compact two-way design with medium velocity air flow.
• Coils are copper tube with aluminum fins.
• Expansion valve mounts inside the cabinet.
• Mounts flush to the ceiling and draws air in through the fan
and discharges out both sides.
• Air pattern reduces air loss when doors are opened and the
medium velocity reduces product drying.
• Textured aluminum cabinet.
• Stainless steel fasteners.
• Molded Lexan® fan guards - safety approved.
• Internal junction box is provided for electrical connection.
• Motors are thermally protected and permanently lubricated.
• UL listed for the United States and Canada; UL classified to
NSF standards.
• Optional corrosion-resistant coated coil available (Model
BTOK) for optimum protection in corrosive environments.
• Drain pan and fan panel is easily removed for installation
and servicing.
Performance/Electrical Data
BTO(K)
MODEL
MOTOR DATA
BTUH
115/1/60 208-230/1/60
NOMENCLATURE
BTO K 09 A E
NO. 10
°
T.D. 15°T.D. CFM QTY TOTAL FLA TOTAL FLA
09
13
18
25
35
45
55
900
1350 130
1950 240
2700 255
3750 460
5250 425
6750 550
8250 730
1
2
1
2
2
2
1
0.8
1.6
1.0
2.0
2.0
2.0
2.1
0.4
0.8
0.5
1.0
1.0
1.0
1.1
BTO = Twin Flow
Vintage
1300
1800
2500
3500
4500
5500
Unit Cooler
A = 115/1/60
K = Coated Coil
B = 208-230/1/60
(Optional)
Size
DIMENSIONAL DATA
BTO(K)
APPROX.
SHIP
MODEL CONNECTIONS (INCHES)
DIMENSIONS (INCHES)
WT.
(LBS.)
12
14
15
23
24
34
34
NO.
09
INLET SUCTION DRAIN
A
B
C
D
4
4
4
4
4
6
6
E
F
G
H
J
K
L
M
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 FN
1/2 ID
1/2 ID
1/2 ID
1/2 ID
1/2 ID
1/2 ID
1/2 ID
1/2 OD
1/2 OD
1/2 OD
1/2 OD
1/2 OD
5/8 OD
5/8 OD
161/8 191/8
161/8 191/8
161/8 191/8
79/16
79/16
79/16
25/16
25/16
25/16
99/16 23/4 47/8 41/2 85/8 21/2 25/8
99/16 23/4 53/4 41/2 85/8 21/2 25/8
99/16 23/4 53/4 41/2 85/8 21/2 25/8
13
18
25
35
181/8 261/8 111/16
181/8 261/8 111/16
211/8 291/8 119/16
211/8 291/8 119/16
25/16 131/16 23/4 63/4 51/2 121/8 31/2 25/8
25/16 131/16 23/4 63/4 51/2 121/8 31/2 25/8
45*
55*
37/16 149/16 31/2 91/4
37/16 149/16 31/2 81/2
8
8
135/8 53/8 41/4
135/8 53/8 41/4
* Sizes 45 and 55 use external equalized expansion valve.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Model TA
Thin Profile Air Defrost Reach In Unit Cooler
APPLICATION
Model TA is a thin profile unit which mounts in the top of a
refrigerator and makes the entire top shelf area usable. The
attractive low silhouette makes this unit cooler particularly
desirable for display type refrigerators. It can also be used in
back bars, under counter cabinets or wherever space is at a
premium.
For 35˚ to 45˚F fixtures at 10˚F to 15˚F TD applications with 16
hours maximum compressor run time per day.
FEATURES
• Textured aluminum cabinet.
• Molded Lexan® fan guards and fan blades.
• Internal junction box for electrical connection.
• UL listed for the United States and Canada; UL classified to
NSF standards.
• Drain fitting mounted at 45-degree angle so drain can be run
through the back or bottom of refrigerator.
• Optional corrosion-resistant coated coil available (Model
TAK) for optimum protection in corrosive environments.
• Stainless steel screws.
• Motors thermally protected and permanently lubricated.
• Convenient, moisture-proof motor plug.
Performance/Electrical Data
MOTOR DATA
115/1/60
QTY
CONNECTIONS (INCHES)
COIL
APPROX.
SHIP WT.
(LBS.)
14
17
MODEL
TA
10
BTUH
10°F TD
1000
1300
1700
2300
3000
4300
5500
208-230/1/60
TOTAL FLA TOTAL FLA
CFM
120
170
210
330
360
540
650
INLET
SUCTION
3/8ID
DRAIN
1
2
2
3
3
4
5
0.8
1.6
1.6
2.4
2.4
3.2
4.0
0.4
0.8
0.8
1.2
1.2
1.6
2.0
1/2FN
1/2FN
1/2FN
1/2FN
1/2FN
1/2FN
1/2FN
1/2OD
1/2OD
1/2OD
1/2OD
1/2OD
1/2OD
1/2OD
13
17
23
30
†43
†55
3/8ID
3/8ID
21
28
33
44
3/8ID
1/2ID
5/8ID
5/8ID
53
† Models 43 and 55 use external equalized expansion valve.
Dimensional Data
MODEL
DIMENSIONS (INCHES)
TA
10
13
17
23
30
43
55
A
B
14
14
15
15
15
15
15
C
D
E
101/2
101/8
111/8
13
13
13
13
F
H
J
K
L
M
W
145/8
185/8
221/8
293/4
381/8
511/2
511/2
15/16
15/16
15/16
15/16
15/16
15/16
15/16
131/2
131/2
141/2
141/2
141/2
141/2
141/2
113/8
101/4
12
41/2
41/2
41/2
41/2
41/2
41/2
63/4
87/8
21/2
91/2
111/4
101/4
93/4
131/4
11
15/16
15/16
15/16
15/16
15/16
15/16
15/16
43/8 161/2
83/8
43/8 201/2
93/8
43/8
24
207/8
293/4
483/4
49
103/4
103/4
103/4
103/4
43/8 315/8
43/8
40
43/8 533/8
43/8 533/8
NOMENCLATURE
TA (K) 17 B E
TA= Thin Profile
Air Defrost
Vintage
A = 115/1/60
B = 208-230/1/60
K = Coated Coil
(Optional)
Size
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Model TL
Thin Profile Electric Defrost Reach In Unit Cooler
APPLICATION
The TL low temperature unit cooler has a completely
automatic defrost system. Mounted in the top of a
refrigerator, its extremely compact cabinet makes it possible
to utilize the entire top shelf area for storage. Having a
normal operating range of +15°F to -20°F, this unit is ideally
suited for such applications as commercial freezers, ice cream
boxes, and bakery freezers.
FEATURES
• Electric defrost insures positive heat source.
• Built-in fan delay allows coil to be chilled before returning
to the normal cooling cycle.
• Stainless steel screws.
• Defrost terminates on coil temperature eliminating
excessive defrost period.
• Motors are thermally protected and permanently lubricated.
• Internal junction box for electrical connection.
• Defrost termination and fan delay control, terminal block
and junction box are mounted inside the cabinet.
• Plate type aluminum fins with full collars - copper tubes.
• Coils are dehydrated and sealed.
• Textured aluminum cabinet.
• Molded Lexan® fan guards - safety approved.
• Easy to install and maintain.
• Knockouts provided on sides for electrical connections -
opening in rear for coil connections.
• UL listed for the United States and Canada; UL classified to
NSF standards.
Performance/Electrical Data
BTUH 10˚F TD
MODEL +20˚F -10˚F
MOTOR DATA
115/1/60 208-230/1/60
HEATER DATA
115/1/60 208-230/1/60 COIL
CONNECTIONS (INCHES) APPROX.
SHIP WT.
INLET SUCTION DRAIN (LBS.)
TL
09
SST SST CFM QTY TOTALFLA
TOTALFLA WATTS AMPS
AMPS
2.1
2.6
1050
900 110
1
2
2
1
3
2
3
0.8
1.6
1.6
1.0
0.4
0.8
0.8
0.5
1.2
1.0
1.5
475
600
700
1100
1430
1600
1950
4.1
5.2
1/2FN
1/2FN
1/2FN
1/2FN
1/2FN
1/2FN
1/2FN
3/8ID
3/8ID
1/2ID
1/2ID
5/8ID
5/8ID
7/8ID
1/2OD
1/2OD
1/2OD
1/2OD
1/2OD
1/2OD
1/2OD
14
19
23
24
27
38
53
12
16
21
28
*35
*53
1380 1200 210
1780 1600 210
2400 2100 240
3200 2800 335
4000 3500 420
6100 5300 595
6.1
9.6
3.0
4.8
-----
-----
-----
-----
-----
-----
5.7
7.0
8.5
* These models use external equalized expansion valves.
DIMENSIONAL DATA
MODEL
DIMENSIONS (INCHES)
TL
09
12
16
21
28
35
53
A
B
14
14
C
D
E
F
H
J
K
L
M
43/8
43/8
43/8
43/8
43/8
6
N
---
---
---
---
---
P
1
1
1
W
145/8
185/8
221/8
221/8
293/4
353/4
461/2
15/16
15/16
15/16
15/16
15/16
15/16
11/8
131/2 101/2
131/2 101/8
141/2 111/8
161/2 141/2
113/8
101/4
12
41/2
41/2
41/2
63/4
63/4
63/4
63/4
87/8
83/8
93/8
21/2
91/2
111/4
15/16
15/16
15/16
15/16
15/16
15/16
11/2
161/2
201/2
24
15
161/2
15
187/8
203/4
331/4
44
117/8 171/4
11/2
24
141/2
161/2 141/2
161/2 141/2
13
93/4
97/8
1
11/2
11/2
315/8
383/8
491/8
161/2
161/2
115/8 183/8
115/8 303/8
51/8
51/8
6
NOMENCLATURE
TL 12 A F
TL = Thin
Vintage
Profile
Electric
Defrost
A = 115/1/60
B = 208-230/1/60
Size
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Model KMK
Mullion Reach In Unit Cooler
APPLICATION
The KMK Mullion is ideal for under-counter reach-in
refrigerators. The thin line design allows the unit to be
mounted behind the mullion with sufficient clearance for
tray slides. A down flow fan arrangement is used with air
drawn in at the top and discharged at the bottom. This
design provides superior air circulation and insures
uniform temperature throughout the cabinet.
This versatile design is also adaptable for mounting on the
back wall or ends of a cooler. The method of air circulation
insures minimum box temperature rise when the cabinet
doors are open. Ideal for bottle goods and beverage coolers.
EXCLUSIVE CORROSION-RESISTANT COATING IS STANDARD
The finned coil is protected by a special dip coating that is
baked on. It prevents corrosion of the coil caused by acids
that are present in many food service and storage coolers.
• Motors are thermally protected and permanently
lubricated.
FEATURES
• Textured aluminum cabinets.
• Internal junction box for electrical connection.
• PVC coated fan guard.
• Stainless steel hardware.
• Adjustable air deflector included provides different air
patterns. Air can be directed where it is needed.
• UL listed for the United States and Canada; UL classified to
NSF standards.
• Coils have full collar aluminum fins on expanded copper
tubes.
• Corrosion-resistant coated coil for optimum protection in
corrosive environments.
• Refrigerant connection knockouts provided on both ends
of unit.
• Expansion valve mounts inside the unit.
Performance/Electrical Data
MOTOR DATA
APPROX.
MODEL BTUH
115/1/60 208-230/1/60
CONNECTIONS (IN.) SHIPPING
INLET SUCTION DRAIN WT. (LBS.)
KMK 10 F TD CFM QTY TOTAL FLA TOTAL FLA
°
13
17
23
1300
1700
2300
180
170
255
2
2
3
1.6
1.6
2.4
0.8
0.8
1.2
1/2FN 3/8OD 5/8OD
1/2FN 3/8OD 5/8OD
1/2FN 3/8OD 5/8OD
19
20
28
DIMENSIONAL DATA
MODEL
NOMENCLATURE
DIMENSIONS (INCHES)
KM K 13 A E
KMK = Mullion
Unit Cooler
Vintage
KMK
13
17
H
L
M
9
W
X
Y
Z
17 3/4
19 3/4
19 3/4
16 7/8
16 7/8
23 1/4
15 5/8
15 5/8
22
2 3/4
2 3/4
2 5/16
5 1/2
6 1/2
6 1/2
6 15/16
7 15/16
7 15/16
A = 115/1/60
B = 208-230/1/60
K = Coated
Coil
10
10
23
Size
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Model RAMK
Reverse Air Flow Mullion Reach In Unit Cooler
APPLICATION
The model RAMK is ideal for under-counter reach-in
refrigerators, under-counter drawer type refrigerators and
salad bars. The unit is suitable for mounting behind a mullion
or on a wall. An up flow air pattern is used with air drawn in
at the bottom and discharged out the top. This provides
optimum temperature for drop in trays on salad bars or prep
tables. It also keep drawer stored product in premium
condition.
An adjustable and detachable air deflector/splash protector is
included. The deflector can be adjusted to direct the air up
and out at a 45-degree angle. This feature provides excellent
air distribution over drop in trays or containers. Food in the
trays and containers stays colder, lasts longer, and retains the
desired appearance. The deflector can be adjusted to
distribute air out both sides when used as a mullion unit.
EXCLUSIVE CORROSION-RESISTANT COATING IS STANDARD
• Refrigerant connection knock-outs provided on both ends of
The finned coil is protected by a special dip coating that is
unit.
baked on to prevent corrosion of the coil by acids that are
present in salad dressings, spiced meats and other food
products.
• Expansion valve mounts inside the unit.
• Motors are thermally protected and permanently lubricated.
• Internal junction box for electrical connection.
FEATURES
• Textured aluminum cabinet.
• Adjustable air deflector included provides different air
patterns. Air can be directed where its needed.
• PVC coated fan guard.
• Stainless steel hardware.
• UL listed for the United States and Canada; UL classified to
NSF standards.
• Corrosion-resistant coated coil for optimum protection in
corrosive environments.
• Coils have full collar aluminum fins on expanded copper
tubes.
Performance/Electrical Data
MOTOR DATA
APPROX.
MODEL BTUH
115/1/60 208-230/1/60
CONNECTIONS (IN.) SHIPPING
INLET SUCTION DRAIN WT. (LBS.)
KMK 10 F TD CFM QTY TOTAL FLA TOTAL FLA
°
13
17
23
1300
1700
2300
180
170
255
2
2
3
1.6
1.6
2.4
0.8
0.8
1.2
1/2FN 3/8OD 5/8OD
1/2FN 3/8OD 5/8OD
1/2FN 3/8OD 5/8OD
19
20
28
NOMENCLATURE
DIMENSIONAL DATA
MODEL
DIMENSIONS (INCHES)
RAM K 13 A E
RAM = Reverse
Air Flow
Mullion
Vintage
RAMK
13
17
H
L
M
9
W
X
Y
Z
17 3/4
19 3/4
19 3/4
16 7/8
16 7/8
23 1/4
15 5/8
15 5/8
22
2 3/4
2 3/4
2 5/16
5 1/2
6 1/2
6 1/2
6 15/16
7 15/16
7 15/16
A = 115/1/60
B = 208-230/1/60
Unit Cooler
10
10
23
K = Coated
Coil
Size
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Model U
Dual Aire Reach In Unit Cooler
FEATURES
•
•
•
•
Textured aluminum cabinet.
Full collar aluminum fins on expanded copper tubes.
Detachable drain pan that is easy to clean.
Molded 3-prong motor connector to save installation time
and expense.
APPLICATION
The U unit cooler is used wherever a small, compact unit is
required. It can be mounted on the ceiling or wall. The model
U unit draws air through the front and discharges it out both
sides to insure proper distribution of cool air and thus maintain
a uniform box temperature.
•
•
•
Motors are thermally protected and permanently
lubricated.
Optional coated coil available (Model UK) for optimum
protection in corrosive environments.
All sizes UL-component recognized and NSF approved.
Performance/Electrical Data
MOTOR DATA CONNECTIONS (In.) APPROX.
115/1/60V 208-230/1/60V COIL SHIPPING
MODEL BTUH CAPACITY
U
09
12
15
10°TD 15°TD CFM TOTAL FLA
TOTAL FLA
INLET SUCTION WT. (LBS.)
850
1150
1500
1275
1725
2250
190
250
310
.45
.45
1.10
.55
.55
.55
1/2 FN
1/2 FN
1/2 FN
3/8 ID
3/8 ID
3/8 ID
9
10
14
PHYSICAL DATA
MODEL
DIMENSIONS (In.)
U
09
12
15
H
W
D
A
6
12
12
B
4
4
4
C
8 1/2
8 1/2
9 1/2
11 1/2
17 1/2
17 1/2
8 7/8
8 7/8
10 7/8
3 1/2
9 1/2
9 1/2
DIMENSIONAL DIAGRAM
NOMENCLATURE
U (K) 09 0
U = Dual Aire
Unit Cooler
0 = 115/1/60
1 = 208-230/1/60
K = Coated Coil
(Optional)
Size
1 0
Download from Www.Somanuals.com. All Manuals Search And Download.
Models BBM/BBL
Back Bar Reach In Unit Cooler
APPLICATION
The BB models are compact, wall-mounted units whose low
height makes them ideal for undercounter reach-in or drawer-
type fixtures. The unit draws air in at the bottom and
discharges out the front. An optional air deflector is included
and can be mounted over the center of the fan to direct air up
and out. The deflector can be field-formed to direct the air
where needed, usually onto drop-in trays of condiments in
salad bar or sandwich preparation fixtures. An S-type
mounting angle is included to position the unit 3/4" off the
wall which gives optimum air circulation and performance.
• Knockouts are conveniently located for refrigerant lines.
• Screws are hardened, stainless steel with a bright zinc
plating.
• Expansion valve mounts inside the cabinet and connections
are sweat-type.
• Motors are thermally protected and permanently lubricated.
• Master units include the basic unit plus factory mounted
Sporlan FV1/5C, R-22, 1/4” x 1/2” sweat expansion valve,
Sporlan E3S, 1/4” x 1/4” sweat solenoid, and Ranco A-30
temperature control. Also right-hand piping extended 8" -
12" outside the housing, sealed and pressurized to 20 - 30
PSI. A 1/4” O.D. liquid feed to slave is included.
• Slave units include the basic unit plus factory mounted
Sporlan FV1/5C, R-22, 1/4” x 1/2” sweat expansion valve
with left-hand piping extended 8" - 12" outside the housing,
sealed and pressurized to 20 - 30 PSI.
The BBM (medium temperature) model is designed for 35° to
40° F. fixture temperature with off-cycle defrost. The unit is
designed to operate at 10° to 17° TD and 16 hours per day
compressor run time.
The BBL (low temperature) model is designed for 0° to -10° F
fixture temperature, and has automatic electric defrost. The
unit is designed to operate at 8° to 15° TD with 18 hours per
day compressor runtime. The BBL has an incoloy sheath
heater embedded in the bottom fin surface for efficient and
fast defrosting. A drain pan heater is included to insure
complete condensate drainage. A disc-type sealed defrost
termination/fan delay control is mounted and wired. Field
connectors are located at the terminal board.
FEATURES
• Molded Lexan® fan blades and guards.
• Coils have copper tubes with aluminum fins, mechanically-
bonded for efficient heat transfer. The coils are dehydrated
and sealed.
• Textured aluminum cabinet.
NOMENCLATURE
Performance/Electrical Data
MOTOR DATA
115/60/1
DEFROST HEATERS
115/60/1 208-230/60/1
BB L S 10 A A
BB = Back Bar
MODEL BTUH
208-230/60/1
Revision
Unit Cooler
BB
L10
M11
L15
M16
10
°
F TD CFM QTY HP
TOTAL FLA TOTAL FLA WATTS
AMPS
2.7
---
AMPS
1.4
---
A = 115/1/60
B = 208-230/1/60
1,000
1,100
1,500
1,600
90
90
1
1
2
2
1/150
1/150
1/150
1/150
0.8
0.8
1.6
1.6
0.4
0.4
0.8
0.8
275
---
L = Low Temp Unit
M = Med. Temp Unit
180
180
350
---
3.5
---
1.7
---
Blank = Standard Unit
S = Slave Unit
Size
M = Master Unit
Dimensional Data
APPROX.
MODEL
BB
L10
M11
L15
M16
DIMENSIONS (INCHES)
SHIPPING
WT. (LBS.)
W
A
B
18
C
171/2
171/2
24
D
E
F
TYPICAL
SECTION
OF SANDWICH
STATION
MODEL BBM
193/4
193/4
261/4
261/4
191/8
191/8
255/8
255/8
71/16
71/16
413/16
413/16
----
----
85/8
85/8
165/8
165/8
231/8
231/8
17
16
20
19
18
241/2
241/2
24
1 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Visit our web site at www.heatcraftrpd.com
for Technical Literature Online.
Since product improvement is a continuing effort at Chandler, we
reserve the right to make changes in specifications without notice.
A Product Line of
Heatcraft Inc. Refrigeration Products
2175 West Park Place Blvd.
Stone Mountain, GA 30087
(770) 465-5600 • Fax (770) 465-5990
1 2
Download from Www.Somanuals.com. All Manuals Search And Download.
|