REMOTE CONTROLLER  
MANUAL  
DVC/DVH Series  
Inverter Single Zone  
Ductless Mini-Split  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller  
DVC/DVH Remote Controller  
Remote Control Instructions  
The remote controller can be used to control and operate the unit  
The remote’s signal can transmit up to 26 ft. (8 m) away.  
Any obstructions between the signal of the remote control and the  
indoor unit can interfere, limiting the capacity of the signal.  
When a button is pressed on the remote control, the indoor unit  
will emit a “beep”, which indicates that the command has been  
received and transmitted to the indoor unit.  
26 ft.(8 m)  
!
CAuTION  
• The air conditioner will not operate if curtains, doors or other materials block the signal from the  
remote control to the unit.  
• Avoid spilling any liquid into the remote.  
• Do not expose to direct sunlight or heat.  
• If the infrared signal receiver on the indoor unit is exposed to direct sunlight, the air conditioner  
may not function properly. Use curtains to prevent the sunlight from interferring with the  
receiver’s signal.  
• If other electrical appliances signals react to the signal sent by the remote controller relocate  
these appliances.  
• When replacing batteries, do not use old batteries  
•If you do not use the remote for a prolonged period of time, remove the batteries. Otherwise  
they may leak and damage the remote  
Battery Specification  
To use the remote control, it is necessary to install two (R03/LR03x2) alkaline AAA batteries.  
Battery Replacement  
1. Batteries should be replaced when there is not a “beep” heard from the indoor unit or the signal  
indicator light does not illuminate when buttons are pressed on the remote or when the indoor unit  
does not respond to the remote controls commands.  
2. To replace the batteries:  
A. Remove the cover by pressing and sliding off.  
B. Remove the old batteries and insert the new batteries, placing the (+) and (-) ends correctly.  
C. Reattach the cover by sliding it back into position.  
NOTE: When the batteries are removed, the remote controller erases all user settings. After inserting  
new batteries, the remote controller must be reprogrammed for any user specific settings.  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
DVC/DVH Remote Controller  
Heat Controller  
Remote Controller Specifications  
Model  
RG52B/BGEu  
3.0V  
Rated Voltage  
Signal Transmission Distance  
Operating Environment  
26ft (8m) with full batteries  
23°F~ 140°F (-5~60°F)  
Performance Features  
1. Operating Modes: AUTO, COOL, DRY, HEAT  
(heat pump models only) and FAN.  
2. 24 hour timer  
3. Temperature Range Selection: 62°F~ 86°F.  
4. LCD (Liquid Crystal Display)  
NOTE: Remote controller can be set to display degrees in °C  
or °F. To alternate between unit of measure, press and hold  
the temp  
and  
button at the same time. Release  
buttons when the unit of measure changes. Repeat the  
process to revert back to the previous unit of measure.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller  
DVC/DVH Remote Controller  
Functions  
1
2
ON/OFF  
Press this button to power on, which starts the unit’s  
operation. Push the button again to power off, which  
stops the unit’s operation.  
MODE  
Each time this button is pressed, a mode is selected in  
a sequence of AUTO, COOL, DRY, HEAT*, and FAN  
then repeat.  
*
*Heat mode is applicable to heat pump models only.  
3
4
FAN  
Press to select the fan speed in four intervals:  
SLEEP  
Press this button to activate the SLEEP mode. Press it  
again to deactivate. This feature can only be selected  
when the unit is in COOL, HEAT*, or Dry mode. Use this  
feature for the most comfortable temperature control  
while you sleep and your body temperature rises.  
*Heat mode is applicable to heat pump models only.  
5
TuRBO  
Activates or deactivates the Turbo function. Press this  
button for Turbo function. Turbo function enables the  
unit to reach the set temperature in the shortest time. In  
the cooling mode, the unit will blow cold air at a super  
high fan speed. In heating mode*, the unit will blow hot  
air a super high fan speed.  
*Heat mode is applicable to heat pump models only.  
6
SELF CLEAN  
This function helps to keep the inside of the unit dry and  
prevents mold from forming. It is particularly useful at  
the end of the season when the unit will not be in use  
for a long period of time. Press the self clean button to  
initiate the self cleaning function.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
DVC/DVH Remote Controller  
Heat Controller  
Functions  
7
TEMP uP (  
)
Push this button to increase the indoor temperature set  
point in 1°F increments up to 86°F.  
TEMP DOWN (  
)
Push this button to decrease the indoor temperature set  
point in 1°F increments down to 62°F.  
8
SHORTCuT  
• Used to restore the current settings or resume the  
previous setting.  
• The first time the unit is powered on and the  
SHORTCUT button is pressed, the unit will operate in  
AUTO mode, 80°F set temp, and auto fan speed.  
• Pushing this button will automatically revert back to  
the previous settings including operating mode, set  
temperature, fan speed level and sleep feature (if  
activated) and transmit the signal to the unit.  
• When this button is pressed for more than 2  
seconds, the system will automatically restore the  
current operation settings including operating mode,  
set temperatures, fan speed and sleep feature (if  
activated).  
9
TIMER ON  
Press the button to initiate the auto-on timer sequence.  
Each press will increase the auto-on timer setting in  
30 minutes increments. When the set time displays 10,  
each addition time the button is pressed, it will increase  
the auto-on timer setting in 60 minute increments. To  
cancel the auto-on timer program, simply adjust the  
auto-on time to 0.0.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller  
DVC/DVH Remote Controller  
Functions  
10  
TIMER OFF  
Press the button to initiate the auto-off timer sequence.  
Each press will increase the auto-timer setting in  
30 minutes increments. When the set time displays  
10, each additional time the button is pressed it will  
increase the auto-timer setting in 60 minute increments.  
To cancel the auto-timer program, simply adjust the  
auto-off timer to 0.0.  
11  
DIRECT  
Press this button to direct the airflow by selecting the  
position of the louver on the unit. Each time the button  
is pressed the louver will open/close by 6° increments.  
NOTE: If the louver moves in a position that could affect  
the cooling or heating (heat pump models only) of the  
air conditioner, the unit will alter the direction of the  
louver angle automatically.  
12  
SWING  
Press this button to start/stop the auto swing feature,  
which the louver oscillates up and down.  
NOTE: If the louver oscillates or moves in a position  
that could affect heating (heat pump models only) or  
cooling of the air conditioner, the unit will automatically  
adjust the louver position.  
13  
FOLLOW ME  
Push this button to initiate the Follow Me mode. In  
follow me mode, the temperature sensor built into the  
remote control senses the room temperature in place of  
the sensor inside the indoor unit. This allows the remote  
control to control the temperature of the room where  
it is present. This feature helps prevent temperature  
stratification. When in follow me mode, the remote  
control display will show the actual room temperature it  
senses.  
14  
LED  
Disables/Activates the indoor \Display. When pushing  
the button, the indoor screen is cleared, press it again  
to turn on the light of the display.  
7
Download from Www.Somanuals.com. All Manuals Search And Download.  
DVC/DVH Remote Controller  
Heat Controller  
Remote Control Display  
MODE  
Displays the current operation mode. Including auto (  
),  
cool (  
auto (  
), dry (  
).  
), heat* (  
), fan (  
) and back to  
*Applicable to heat pump models only  
TRANSMISSION INDICATOR  
This transmission indicator lights when remote controller  
transmits signals to the indoor unit.  
ON/OFF  
Shows when unit is on.  
TIMER ON  
Displays when TIMER ON time is set.  
TIMER OFF  
Displays when TIMER OFF time is set.  
SLEEP  
Displays when in SLEEP MODE.  
FOLLOW ME  
Displayed when FOLLOW ME function is activated.  
TEMP./TIMER DISPLAY  
Displays the set temperature (62°F~86°F). When the  
operating mode is set to FAN, no set temperature is  
displayed. In TIMER mode, set the ON and OFF time settings  
are displayed.  
FAN  
Displays the FAN speed, AUTO (no display) and three  
fan speed levels “  
(MED) “  
” (LOW )“  
” (HIGH) can be indicated. The fan  
speed is AUTO when the operating mode is in AUTO or DRY.  
8
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller  
DVC/DVH Remote Controller  
Remote Operation  
AuTO OPERATION  
1. Press the MODE button to select Auto.  
2. Press the UP/DOWN button to set the desired  
temperature. The temperature can be set within a  
range of 62°F~86°F in 1°F increments.  
• In Auto mode, the unit will automatically select  
Cool, Fan or Heat* modes be sensing the  
difference between the actual ambient room  
temperature and the set temperature on the remote  
controller.  
• In the Auto mode, you can not charge the fan  
speed. It is being automatically controlled.  
COOLING/HEATING/FAN OPERATION  
If Auto mode is uncomfortable, you can manually  
override the setting by putting the unit in COOL, HEAT*,  
or FAN** ONLY mode.  
1. Press the MODE button to select COOL, HEAT*  
(pump) or FAN** mode.  
2. Press the temp UP/DOWN button to set the desired  
temperature. The temperature can be set within a  
range of 62°F~86°F in 1°F increments.  
3. Press the FAN button to select the fan speed in four  
steps - Auto, Low, Med, or High.  
NOTE  
* Heat mode is applicable to heat pump models only.  
** In the FAN mode, the set temperature is not  
displayed on the remote controller and you are not  
able to control the room temperature either. In this  
case, only the fan speed can be changed.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
DVC/DVH Remote Controller  
Heat Controller  
Remote Operation  
DRY OPERATION  
The DRY mode will automatically select the amount of  
dehumidification based on the difference between the  
set temperature and actual room temperature. The fan  
speed is automatically set to low.  
1. Press the MODE button to select DRY mode.  
2. Press the UP/DOWN buttons to set the desired  
temperature. The temperature can be set within a  
range of 62°F~86°F in 1°F increments.  
NOTE  
• In the Dry mode, you can not change the fan speed. It  
is ceing automatically controlled.  
• Due to the difference between the set temperature  
and the actual room temperature, the unit will  
automatically switch between COOL and FAN only  
mode while in DRY mode.  
ADJuSTING AIR FLOW DIRECTION  
Use the SWING or DIRECT button to adjust the desired  
airflow direction.  
1. When the DIRECT button is pushed the horizontal  
louver changes in 6° degree angle increments.  
2. When the SWING button is pushed the louver  
oscillates.  
NOTE  
When the louver oscillates or moves in a position that  
could affect the cooling or heating (heat pump models  
only) of the air conditioner, the unit will automatically  
change the louver direction.  
1
2
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller  
DVC/DVH Remote Controller  
Remote Operation  
TIMER OPERATION  
Press the TIMER ON button to set the time the unit  
should automatically turn on. Press the TIMER OFF  
button to set the time the unit should automatically turn  
off.  
1. Press the TIMER ON button. The remote controller  
show TIMER ON, the last Auto-on set time and the  
“H” icon will be shown on the LCD display. Now it is  
ready to reset the Auto-on time to START operation.  
2. Push the TIMER ON button again to set desired Auto-  
on time. Each time you press the button, the time  
increases by half an hour between 0 and 10 hours  
and by one hour between 10 and 24 hours.  
3. After setting the TIMER ON, there will be a one  
second delay before the remote controller transmits  
the signal to the air conditioner. Then, after  
approximately another 2 seconds, the “H” icon will  
disappear and the set temperature will re-appear on  
the LCD display.  
TO SET THE AuTO-OFF TIME  
1. Press TIMER OFF button. The remote controller  
show TIMER OFF, the last Auto-off setting time  
and the “H” icon will be shown on the LCD display  
area. Now it is ready to reset the LCD display area.  
Now it is ready to reset the Auto-off time to stop the  
operation.  
2. Push the TIMER OFF button again to set desired  
Auto-off time. Each time you press the button, the  
time increases by half an hour between 0 and 10  
hours and by one hour between 10 and 24 hours.  
3. After setting the TIMER OFF, there will be a one  
second delay before the remote controller transmits  
the signal to the air conditioner. Then, after  
approximately another 2 seconds, the signal “H” will  
disappear and set the temperature will re-appear on  
the LCD display.  
1
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DVC/DVH Remote Controller  
Heat Controller  
Remote Operation  
SLEEP FuNCTION  
The sleep function enables the unit to automatically  
change the temperature by 2°F per hour for the first two  
hours, then will remain steady for the next 5 hours, after  
that the unit will stop operating. SLEEP mode creates  
comfortable temperatures and saves energy.  
1. When the SLEEP mode is selected while in COOL  
mode, the temperature increases to create the  
most uncomfortable conditions while your body  
temperature rises when you sleep. When SLEEP  
is selected while in HEAT* mode, the temperature  
deceases to ensure you don’t get too hot while your  
body temperature rises when you sleep.  
NOTE  
The SLEEP function is only selectable when  
the unit is in COOL, HEAT* or AUTO modes.  
* Heat pump is applicable to heat pump models only.  
1
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller  
DVC/DVH Remote Controller  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DVC/DVH Remote Controller  
Heat Controller  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Heat Controller  
DVC/DVH Remote Controller  
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DVC/DVH Remote Controller  
Heat Controller  
Design, material, performance specifications and components  
subject to change without notice.  
ꢀꢁꢂꢂꢃ:HOOZRUWKꢃ$YHꢄꢅꢃ-DFNVRQꢃ0,ꢃꢆꢁꢇꢂꢈꢃꢃ‡ꢃꢃ3Kꢄꢃꢉꢀꢊꢋꢊꢌꢊꢋꢇꢀꢂꢂꢃꢃ‡ꢃꢃZZZꢄKHDWFRQWUROOHUꢄFRP  
ꢃꢃ  
16  
07/2013  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Monitor 2M17 User Manual
Greenheck Fan Gas Heater 470654 User Manual
Haier Air Conditioner HSU 18LE03 User Manual
Hamilton Beach Iron 19701 User Manual
HANNspree Flat Panel Television JT02 37E1 User Manual
Hasbro Motorized Toy Car 06842 06853 User Manual
Hotpoint Refrigerator MSZ User Manual
HP Hewlett Packard Car Amplifier 463A User Manual
HP Hewlett Packard Power Supply Power Management System User Manual
IKEA Indoor Furnishings AA 54067 4 User Manual