BEFORE USE  
1.  
READ THIS ENTIRE INSTRUCTION MANUAL BEFORE USE  
Keep your ORIGINAL purchase  
receipt.  
Your receipt is your proof of  
purchase and may be necessary  
for warranty service.  
! ATTENTION !  
This manual describes installation, operation, and maintenance of the  
portable air conditioner product.  
If you need assistance, please call:  
CUSTOMER SERVICE  
1-517-787-2100  
FOR FUTURE REFERENCE, PLEASE RECORD THE FOLLOWING:  
Model No.: ________________________________________________  
Serial No.:_________________  
Date of Purchase: _______________________________  
3
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
QUICK SET UP  
2.  
Unpack the unit:  
Remove the foam cap.  
Check to see if unit is complete  
including all parts and  
accessories (Ref. Section 6,  
Parts & Accessories).  
With two people, lift and  
remove the unit from the  
foam packing base  
without tilting the unit.  
Remove the plastic bag.  
Place the unit UPRIGHT to  
allow the refrigerant and oil to  
stabilize. Wait 3 hours before  
using. (Ref. Section 7,  
Safety).  
Test LCDI Plug. (Ref. Section  
7, Safety Rules).  
Attach air inlet and air outlet hose. Follow instructions per Section 8,  
Installation.  
Plug the unit into a properly grounded 15 Amp, 115V AC, circuit. (Ref.  
Section 7, Safety Rules).  
Follow Section 9, Operation to set preferred function mode. When  
Water-Full indicator illuminates, empty the residual condensate water. (Ref.  
Section 10, Drain Excess Condensate Water).  
Handle your unit with care. Move it gently. Always keep air filter clean.  
Do not cover air inlet grid and air outlet grid.  
4
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INTRODUCTION  
3.  
This Portable Air Conditioner is designed for improving living and working  
comfort by adjusting the temperature and humidity in a room. Its mobility  
makes it easy to use in various rooms.  
This unit is provided with one outside air inlet hose and one hot-air outlet hose  
to enhance cooling performance. This unit has an Auto Restart function. In  
case of power failure, the unit will restart in the last setting selected when  
power resumes.  
To ensure the optimal efficiency of the air conditioner, keep doors and windows  
closed. In order to optimize the functioning of your air conditioner, close  
window coverings to minimize sun load in the room.  
This unit has a three-minute compressor delay protection circuit  
SUGGESTIONS FOR USE  
4.  
1. This unit is designed for use indoors only and is not intended for outdoor  
use.  
2. Do not locate the unit where furniture or other objects can obstruct the  
cooling airflow on back or above unit.  
3. Prevent any kink or sharp bend in the air inlet and hot-air outlet hoses.  
4. Unit must always be used in an upright position.  
5. After unpacking, place the unit upright to allow the refrigerant and oil to  
stabilize. Wait 3 hours before using.  
6. Place the unit on the floor not on a table or other elevated surface.  
7. Keep the filter clean.  
5
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SPECIFICATIONS  
5.  
PE-91A / PE-121A  
115V / 60 Hz  
9000 / 12000  
3412 / 4265  
10.0 / 11.5  
8.7 / 10.9  
Electrical Supply  
Cooling Capacity (BTUH)  
Heating Capacity (BTUH)  
Cooling Amps  
Heating Amps  
Dehumidifying Capacity (Pts/Hr)  
Refrigerant  
2.5 / 2.8  
R22  
Fan Speeds  
Low / Med / Hi  
210  
Airflow (CFM)  
Noise Level dB(A)  
51 / 52  
Net Weight (lb)  
85.5 / 87.5  
19.1(W) x 19.4(D) x 31.9(H)  
71  
Product Dimension (in)  
Max. Length of Air Inlet and Outlet Hose (in)  
Programming Timer (hr)  
1 - 24  
6
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PARTS & ACCESSORIES  
6.  
Upper drain port  
Lower drain port  
(Rubber plug inside)  
7
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY  
7.  
Connection to the main electrical supply must comply with local and national  
electrical codes.  
1. Do not damage the power cord.  
2. Never lay this unit down. Operate in upright position only.  
3. Be sure that air inlets and outlets are not blocked or covered up.  
4. Never place anything on top of the unit.  
5. Do not use this product outdoors.  
6. Never connect the unit to a defective outlet.  
7. Plug the unit into a properly grounded 15 Amp, 115V AC circuit. Check  
your breaker box to determine which circuit the outlet is on. A dedicated  
circuit is recommended.  
8. Make sure that the unit is correctly connected before turning on the unit.  
9. Do not use the plug as a disconnecting means.  
10.DO NOT USE AN EXTENSION CORD for this unit.  
11.Do not use an adapter plug to a two slot outlet unless proper grounding of  
the outlet and/or ground wire is verified. Consult an Electrician.  
12.Do not bend or crush the air inlet or air outlet hoses.  
13.Do not allow children to play near the unit.  
14.Do not place the power cord under a carpet.  
15.Keep the area around the exhaust port/air inlet and air outlet hoses  
sufficiently clean and make sure that it is not congested.  
16.For any repairs, refer directly to our Customer Service Department.  
Repairs carried out by unqualified people may cause damage or may  
even be dangerous and may void the warranty.  
DO NOT:  
Place objects inside the air outlet or air inlet grid.  
Use this unit inside closets or cabinets.  
Repair, disassemble and/or modify the unit by yourself.  
Use this unit in proximity to inflammable and/or explosive substances.  
Operate this unit without filter.  
Before cleaning this unit, make sure that it is unplugged. Do not wash the unit  
with water, gasoline or solvents of any kind. (See Section 11).  
To avoid the risk of shock, the product should never be used in bathrooms,  
shower rooms, or in any other steamy or wet areas.  
Do not use the unit on a table as the unit is supported by wheels. Place unit on  
level floor.  
8
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
SAFETY (continued)  
7.  
This unit is provided with Leakage Current Detection and Interruption circuit  
(LCDI) built into the plug of the power supply cord. This device provides  
protection to reduce the risk of fire due to arcing faults in the power supply  
cord. Before use, follow the “Plug Testing Instructions” to ensure that the  
LCDI circuit functions properly.  
PLUG TESTING INSTRUCTIONS:  
1. Press Test Button.  
It should trip.  
2. Press Reset Button  
firmly for use. Reset  
Button may require  
pressure to engage.  
(Plug on unit may vary from picture.)  
DO NOT USE IF ABOVE TEST FAILS  
Do not use the TEST and RESET buttons as an on/off switch. They are  
only meant to be used for periodically checking the LCDI plug.  
CALL CUSTOMER SERVICE IF TEST FAILS.  
Replace defective cords only with genuine replacement parts from  
Heat Controller.  
9
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
8.  
When this portable air conditioner operates in the cool mode, fresh outdoor air  
must be directed into the unit and hot air must be exhausted out of the room to  
complete heat exchange of the condenser. When the unit operates in FAN or  
HEAT mode, no outdoor air is used hence it is not necessary to complete  
window kit installation.  
Installation Kit:  
Telescoping Window Panel Kit  
Air Inlet & Air Outlet Hose (2 sets)  
Unit with Hoses Attached  
Cover the Exhaust Port When Unit Not in Use  
There are two exhaust ports at the back of the unit. Cover the exhaust ports  
when unit is not in use. To ready unit for installation, remove the exhaust port  
cover by turning in a counter-clockwise direction.  
10  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
INSTALLATION  
8.  
8.1 Installation Procedures  
1. Measure the window the unit will be installed into and adjust the telescoping  
Window Panels to fit into the window. If window is either too wide or too  
tall, fill the remaining space with foam or other appropriate material. Make  
sure that the holes on the Window Panel are exposed for connection of  
Window Kit Adaptor.  
2. Screw the hose clockwise into the Terminal End, and the other end of the  
hose to the Window Kit Adaptor. Apply same procedures to both air inlet  
hose and air outlet hose.  
3. Secure the Terminal End to the Exhaust Port. Apply same procedures to  
both air inlet hose and air outlet hose.  
4. Connect the Window Kit Adaptor to each of the holes on the Window Panel.  
VERTICAL  
HORIZONTAL  
11  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
9.  
9.1 Control Panel and Display  
Dry Mode  
NOTE: To toggle the displayed temperature between °C and °F, press the  
ON/OFF button for approximately 20 seconds and then release. (The °F printed  
on the Control Panel will remain unchanged.)  
.
12  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
9.  
9.2 Remote Controller  
FAN SPEED  
ON OFF  
TEMP/TIME  
MODE  
MODE  
TIMER  
Fig. Remote Controller  
The buttons on the Remote Controller perform the same functions as the  
equivalent button on the Control Panel.  
The Remote Controller uses lithium battery Model CR2025. Install battery  
before using the Remote Controller.  
13  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
9.  
9.3 Auto, Cool, Heat, Dry, Fan Mode  
You can operate the unit using the Control Panel on the unit, or with the  
Remote Controller.  
Auto Mode:  
1. Plug the Power Cord into the power outlet.  
2. Turn on the unit by pressing the ON/OFF Button on the Control Panel.  
3. Press the Mode Button until the signal “  
“ appears on the display.  
4. Select the fan speed by using the FAN button.  
During the AUTO mode, the unit will operate in HEAT mode when the room  
temperature is below 70°F.  
The unit will operate in FAN only mode when the room temperature is between  
70°F and 80°F.  
The unit will operate in COOL mode when the room temperature is above 80°F.  
Cool Mode:  
1. Plug the Power Cord into the power outlet.  
2. Turn on the unit by pressing the ON/OFF Button on the Control Panel.  
3. Press the Mode Button until the signal  
appears on the display.  
4. Set the room temperature to your desired room temperature with  
Temperature Changing Button.  
5. Set temperature range from 64°F to 90°F.  
6. Recommended temperature for your comfort: is 82°F to 86°F.  
7. Select fan speed by pressing the FAN Button.  
14  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
9.  
9.3 Auto, Cool, Heat, Dry, Fan Mode  
Heat Mode:  
1. Plug the Power Cord into the power outlet.  
2. Turn on the unit by pressing the ON/OFF Button on the Control Panel.  
3. Press the Mode Button until signal “  
“ appears on the display.  
4. Set the room temperature to your desired room temperature with  
Temperature Changing Button.  
Then set temperature range from 60°F to 82°F.  
We recommend temperature for your comfort between 69°F to 75°F.  
5. Select the fan speed by pressing the Fan Speed Button. It is  
recommended to use a low fan setting.  
The Heating Function is provided by an electric heat element. The  
compressor will not operate in HEAT Mode. It is not necessary to connect any  
of the exhaust hoses to the unit.  
Dry Mode:  
1. Plug the Power Cord into the power outlet.  
2. Turn on the unit by pressing the ON/OFF Button on the Control Panel.  
3. Press the Mode Button until the signal “  
“ appears on the display.  
4. Set the room temperature to your desired room temperature with  
temperature change button.  
5. Keep the windows and the doors closed to aid the effectiveness.  
6. The unit will only operate at low fan speed in Dry Mode. It is  
recommended not to install the exhaust hose for the best dehumidifying  
effect; however, the room may become too warm for comfort. In this case,  
the exhaust hose should be used.  
NOTE: The unit will not perform dehumidifying when the room temperature  
is lower than 64°F.  
Fan Only Mode:  
1. Plug the Power Cord into the power outlet.  
2. Turn on the unit by pressing the ON/OFF Button on the Control Panel.  
3. Press the Mode Button until signal  
appears on the display.  
4. Select the fan speed by pressing the Fan Speed Button.  
15  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
9.  
9.4 Timer Setting Procedure  
ON-TIMER Program Setting:  
When the unit is OFF, you can program the ON TIMER to start the unit after desired  
number of hours. Procedure:  
Preset  
Press TIMER  
button. Digit  
“3” will flash  
on LED  
Press  
or  
10-second  
pause after  
Number of hours on LED  
display will count down as  
time lapses. When the  
display shows “0” , meaning  
programmed hour expires, the  
product will start operation in  
the preset mode. If you do  
not preset mode before  
setting ON TIMER, the unit  
will start in the mode of last  
operation.  
desired  
operation  
mode.  
pressing  
button to  
desired  
hours.  
or  
button  
display.  
signals  
TIMER LED  
indicator will  
illuminate.  
completion of  
timer  
Number  
of hours  
will  
programming.  
appear  
on LED  
HOW TO CANCEL ON-TIMER Program Setting:  
Press TIMER button.  
Number of hours will  
flash on LED display  
Press TIMER button again.  
ON-TIMER program  
cancelled.  
Number of hours will disappear on  
LED display. TIMER LED  
indicator light will turn off.  
OFF-TIMER Program Setting:  
Press TIMER  
button. Digit  
“3” will flash on  
LED display.  
TIMER LED  
indicator will  
illuminate.  
10-second pause after  
When the  
Press  
or  
programmed hour  
expires, the product  
will stop.  
button to  
pressing  
or  
your desired  
button signals  
hours.  
completion of timer  
programming. Indicator  
will illuminate.  
Number of  
hours will  
appear on LED  
display.  
HOW TO CANCEL OFF-TIMER Program Setting:  
Press TIMER button.  
Number of hours will  
flash on LED display  
Press TIMER button again.  
TIMER LED indicator will turn off.  
Set temperature will appear on  
LED display.  
OFF-TIMER program  
cancelled.  
16  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
OPERATION  
9.  
9.5 Air Flow Direction Control  
Horizontal Swing Strip  
H-SWING  
Press  
button. The horizontal swing strip controls the up-down  
air direction and will move up and down automatically. Release  
H-SWING button when the horizontal strip comes to your desired direction.  
Vertical Swing Strip  
V-SWING  
Press  
button once. The vertical strip controls left/right air  
direction and will swing left and right automatically. Press the V-SWING  
button again when the vertical strip comes to your desired direction, the  
vertical strip will stop.  
17  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
DRAIN EXCESS CONDENSATE WATER  
10.  
Condensate Disposal:  
Under normal operating conditions, this unit is designed to dispose of  
condensate collected via an internal system that pumps water onto the hot  
condenser coil for re-evaporation. It is then expelled to the outdoors via the  
air outlet hose. If the unit is operated for prolonged periods during very high  
humidity conditions, this system may become overwhelmed and the unit will  
shut off. Excess water must be drained from the unit before it will restart.  
Lower Drain Port  
Upper Drain Port  
Drain Water from Upper Drain Port:  
Procedures: Connect the Water Drain House to the Upper Drain Port  
allowing water to flow to a water bucket.  
(See above illustration).  
Remember to reinstall the cap on Upper Drain Port after draining water. The  
Upper Drain Port can be used if a floor drain or some other means of  
disposing of condensate is not available.  
Drain Water from Lower Drain Port:  
(Before Long Term Storage Only)  
Procedures: Remove the Rubber Drain Plug on Lower Drain Port.  
Connect the Water Drain Hose to allow water to drain to a floor drain or other  
water outlet. Remember to reinstall the Rubber Drain Plug after draining  
water.  
18  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
11.  
MAKE SURE POWER SUPPLY IS SWITCHED OFF AND THE PLUG IS  
PULLED OUT OF THE POWER OUTLET BEFORE ANY MAINTENANCE IS  
PERFORMED.  
Do not immerse the unit in water or other liquids.  
Do not pour liquids onto the unit.  
Clean the Filter  
If the filter is blocked with dust, the airflow volume will reduce and the cooling  
effect will be reduced.  
It is recommended to clean the filter once every two weeks or as  
needed.  
Remove the filter from the back of the unit by pulling straight up. Wash  
the filter gently with warm water (about 104°F.)  
Dry it thoroughly and then place it back into the product.  
Do not bend the filter.  
Clean Exterior Surface of the Unit  
Clean with a damp sponge.  
Dry it with a clean, soft cloth.  
Never use alcohol or any product containing solvents.  
Long-Term Storage  
At the end of the season, or when you do not plan to use the unit for an  
extended period of time, we recommend that you take the following steps:  
1. Drain water from the lower drain port.  
2. Clean the filter.  
3. Store the power cord  
Upper Drain Port  
Lower Drain Port  
19  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MAINTENANCE  
11.  
11.1 Storing the Power Cord  
To avoid damage to the power cord when the unit is not in use, always store the  
power cord at the back of the unit in its original location (as shown in the figure  
below).  
20  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
TROUBLE SHOOTING  
12.  
Problem  
Cause  
Solution  
Power failure or plug is not  
correctly inserted in the socket  
Circuit breaker or line fuse has  
been tripped  
Restore the power supply or  
reset LCDI  
The unit doesn’t run  
Call your Electrician  
Power supply voltage is too low  
Call your Electrician  
The unit has only fan,  
no cooling even  
though it is in the  
cooling mode  
The room temperature is not at  
working range  
Check your room temperature  
The set temperature is too high  
Re-set the temperature to a lower  
temperature  
The filter is dirty and obstructed  
Evaporator air is blocked  
Clean the filer  
Remove the blockage  
Check both of the ducts  
The unit seems to do  
little cooling or does  
not cool quickly  
The air intake and outlet ducts of  
the condenser side are obstructed  
There is direct sunshine into room Close the curtains or blinds  
The unit is set on dehumidifying  
mode  
Set at cooling mode  
Set at low fan speed  
Re-set the fan speed at high  
speed  
Windows or doors are open.  
Close all of the windows and  
doors when the unit is working  
Turn on other cooling unit  
Turn off these products  
The unit has worked  
for a long time, but the  
room is not cold  
enough  
Too many people in the room  
Something else in the room  
produces heat  
The room is not well insulated,  
such as sunrooms, garages,  
attics, etc.  
The unit is not sitting evenly  
Place the unit on an even surface  
Change the position  
Too noisy  
The floor underneath the unit is  
uneven  
The unit stops cooling The environment is too wet and  
Empty the water inside the unit.  
suddenly, only the fan the condensate water in the unit is Connect a pipe to the upper drain  
works and the  
full  
port (refer to drawing in PARTS  
Of Unit) at the back of the unit  
then restart the unit. Wait for  
approximately 1 hour to let  
condensor side fan blow out the  
water  
Water-Full indicator  
display on the  
control pane is on  
21  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13.  
WIRING DIAGRAM  
Swi ng Mot or  
For Ver t i cal  
Swi ng St r i p  
Swi ng Mot or  
For Hor i zont al  
Swi ng St r i p  
Pr ot ect or  
Fan Mot or For  
Condensor Si de  
Mot or For  
Evapor at or Si de  
C
C1: Runni ng Capaci t or  
For Fan Mot or of  
Condensor Si de  
C2: Runni ng Capaci t or  
For Compr essor  
C3: Runni ng Capaci t or  
For Fan Mot or of  
Evapor at or Si de  
Compr essor  
C1  
C3  
WATER  
PUMP  
SM  
SM  
S
Cut - of f  
Cut - of f  
R
C2  
5C  
Temper at ur e  
Li mi t  
H
AC- N  
HI  
MI  
LI  
WATER  
L
NO  
5C  
UP/ DOWN  
COM  
El ec t r i c al  
He at e r  
Fuse  
3. 15A  
COM  
LEFT/ RI GHT  
Temper at ur e  
Li mi t  
NO  
Mai n  
Cont r ol l er PCB  
N
L
G
3C  
POWER  
SUPPLY  
Room  
Temper at ur e  
Sensor  
Wat er Level  
Det ec t or  
4C  
7C  
Si gnal Recei ver PCB  
Tr ansf or mer  
Hr  
Cont r ol Panel  
PCB  
22  
Heat Controller, Inc.  1900 Wellworth Avenue  Jackson, MI 49203  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Design, material, performance data and components  
subject to change without notice.  
1900 Wellworth Ave., Jackson, Michigan 49203 • Ph. 517-787-2100 • Fax 517-787-9341  
THE QUALITY LEADER IN CONDITIONING AIR  
01/07  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Accessories PD210478D User Manual
Grizzly Lathe G0482 User Manual
Grizzly Saw G0513 User Manual
Haier Freezer HFV160 User Manual
Hans Grohe Plumbing Product 06672XX0 User Manual
HP Hewlett Packard Time Clock HP UX User Manual
Huawei Cell Phone Pillar M615 User Manual
Husqvarna Chainsaw 315 320 User Manual
IBM Network Card DAS16 User Manual
IBM Personal Computer DISA e collaboration User Manual