Heat Controller Air Conditioner BD 101 User Manual

HEAT CONTROLLER, INC.  
Through-The-Wall  
Air Conditioning  
Models: BD-81  
BD-101  
BD-123  
BDE-103  
BDE-123  
Important Information  
• Please read carefully and thoroughly this manual before operating this unit.  
• Contact a qualified sevice technician for installation, repair and maintenance of this unit.  
• The appliance is not intended for use by young children or those who require supervision.  
Young children should be supervised to ensure that they do not play with the appliance.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3 SPECIFICATIONS  
1.3.1 FOR BD-81/BD-101  
MODELS  
BD-81  
BD101  
REMARK  
ITEMS  
POWER SUPPLY  
1Ø, 115V, 60Hz  
COOLING CAPACITY (Btu/h)  
8,000  
800  
10,000  
INPUT  
(W)  
(A)  
1,050  
9.8  
RUNNING CURRENT  
E.E.R  
7.5  
(Btu/w.h)  
10.0  
9.5  
REFRIGERANT (R-22) CHARGE(g)  
380(13.2 OZ)  
410(14.5 OZ)  
INDOOR (°C)  
OPERATING  
26.7(DB) 19.4(WB)  
35(DB) 23.9(WB)  
TEMPERATURE  
OUTDOOR (°C)  
LOUVERED-  
FIN TYPE  
EVAPORATOR  
CONDENSER  
FAN, INDOOR  
FAN, OUTDOOR  
2 ROW 12 STACKS  
2 ROW 17 STACKS, L-BENDED TYPE  
TURBO FAN  
PROPELLER TYPE FAN WITH SLINGER-RING  
3/3  
FAN SPEEDS, FAN/COOLING  
FAN MOTOR  
6 POLES  
OPERATION CONTROL  
ROOM TEMP. CONTROL  
ELECTRIC  
THERMISTOR  
VERTICAL LOUVER(RIGHT & LEFT)  
HORIZONTAL LOUVER(UP & DOWN)  
AIR DIRECTION CONTROL  
CONSTRUCTION  
TOP-DOWN  
EXTERNAL OVERLOAD PROTECTOR  
COMPRESSOR  
PROTECTOR  
FAN MOTOR  
INTERNAL THERMAL PROTECTOR  
1.6m (3WIRE WITH GROUNDING)  
POWER CORD  
ATTACHMENT PLUG(CORD-CONNECTED TYPE)  
SPLASHED BY FAN SLINGER  
DRAIN SYSTEM  
NET WEIGHT  
DIMENSION  
(lbs/kg)  
(inch)  
(mm)  
72/33  
79/36  
21  
13  
21  
24 /32 x 14 /32 x 19 /32  
626 x 366 x 499  
(W x H x D)  
7
17  
23  
25 /8 x 15 /32 x 16 /32  
SLEEVE DIMESION  
(W x H x D)  
(inch)  
(mm)  
OPTIONAL  
PART  
656 x 394 x 425  
20  
SLEEVE DEPTH  
(inch)  
510  
WITH FRONT GRILLE  
(mm)  
—3—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3.2 FOR BD-123  
MODELS  
BD-123  
REMARK  
ITEMS  
1Ø, 208/ 230V, 60Hz  
11,400/11,700  
POWER SUPPLY  
COOLING CAPACITY  
INPUT  
(Btu/h)  
1,200/1,230  
(W)  
(A)  
6.2/5.8  
RUNNING CURRENT  
E.E.R.  
9.5  
(Btu/W.h)  
26.7 (DB) 19.4 (WB)  
35 (DB) 23.9 (WB)  
INDOOR (°C)  
OUTDOOR (°C)  
OPERATING  
TEMPERA-TURE  
465(16.4 OZ)  
REFRIGERANT (R-22) CHARGE(g)  
EVAPORATOR  
2 ROW 11 STACKS  
LOUVERED-  
FIN TYPE  
2 ROW 17 STACKS, L-BENDED TYPE  
TURBO FAN  
CONDENSER  
FAN, INDOOR  
PROPELLER TYPE FAN WITH SLINGER-RING  
3/3  
FAN, OUTDOOR  
FAN SPEEDS (FAN/COOLING/HEATING)  
FAN MOTOR  
6 POLES  
ELECTRIC  
OPERATION CONTROL  
ROOM TEMP. CONTROL  
THERMISTOR  
VERTICAL LOUVER (RIGHT & LEFT)  
HORIZONTAL LOUVER (UP & DOWN)  
TOP-DOWN  
AIR DIRECTION CONTROL  
CONSTRUCTION  
EXTERNAL OVERLOAD PROTECTOR  
INTERNAL THERMAL PROTECTOR  
1.6m (3 WIRE WITH GROUDING)  
ATTACHMENT PLUG (CORD-CONNECTED TYPE)  
SPLASHED BY FAN SLINGER  
80/37  
COMPRESSOR  
PROTECTOR  
FAN MOTOR  
POWER CORD  
DRAIN SYSTEM  
NET WEIGHT  
(lbs/kg)  
(inch)  
(mm)  
(inch)  
(mm)  
(inch)  
(mm)  
21  
13  
21  
24 /32 x 14 /32 x 19 /32  
DIMENSION  
626 x 366 x 499  
(W x H x D)  
7
17  
23  
25 /8 x 15 /32 x 16 /32  
SLEEVE DIMESION  
(W x H x D)  
OPTIONAL  
PART  
656 x 394 x 425  
20  
SLEEVE DEPTH  
WITH FRONT GRILLE  
510  
—4—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.3.3 FOR BDE-103/BDE-123  
MODELS  
ITEMS  
BDE-103  
BDE-123  
REMARK  
1Ø, 208/ 230V, 60Hz  
POWER SUPPLY  
9,800/10,000  
1,030/1,050  
5.2/4.7  
11,400/11,700  
1,200/1,230  
6.2/5.8  
CAPACITY  
INPUT  
(Btu/h)  
(W)  
COOLING  
HEATING  
RUNNING CURRENT (A)  
9.5  
9.5  
E.E.R.  
(Btu/W.h)  
(Btu/h)  
(W)  
9,200/11,200  
2,900/3,500  
14.0/15.3  
CAPACITY  
INPUT  
RUNNING CURRENT (A)  
26.7 (DB) 19.4 (WB)  
35 (DB) 23.9 (WB)  
21.1 (DB) 15.6 (WB)  
INDOOR (°C)  
COOLING  
OPERATING  
TEMPERA-  
TURE  
OUTDOOR (°C)  
INDOOR (°C)  
HEATING  
8.3 (DB)  
440(15.5 OZ)  
2 ROW 12 STACKS  
2 ROW 17 STACKS, L-BENDED TYPE  
6.1 (WB)  
465(16.4 OZ)  
2 ROW 11 STACKS  
OUTDOOR (°C)  
REFRIGERANT (R-22) CHARGE(g)  
EVAPORATOR  
LOUVERED-  
FIN TYPE  
CONDENSER  
TURBO FAN  
PROPELLER TYPE FAN WITH SLINGER-RING  
1/ 2/ 2  
FAN, INDOOR  
FAN, OUTDOOR  
FAN SPEEDS (FAN/COOLING/HEATING)  
FAN MOTOR  
6 POLES  
ROTARY SWITCH  
OPERATION CONTROL  
ROOM TEMP. CONTROL  
THERMOSTAT  
VERTICAL LOUVER (RIGHT & LEFT)  
HORIZONTAL LOUVER (UP & DOWN)  
TOP-DOWN  
AIR DIRECTION CONTROL  
CONSTRUCTION  
ELECTRIC HEATER  
COMPRESSOR  
3.5KW, 208/230V  
EXTERNAL OVERLOAD PROTECTOR  
INTERNAL THERMAL PROTECTOR  
FUSE LINK, BIMETAL THERMOSTAT  
1.6m (3 WIRE WITH GROUDING)  
ATTACHMENT PLUG (CORD-CONNECTED TYPE)  
SPLASHED BY FAN SLINGER  
PROTECTOR  
FAN MOTOR  
ELECTRIC HEATER  
POWER CORD  
DRAIN SYSTEM  
80/36  
81/37  
NET WEIGHT  
(lbs/kg)  
(inch)  
(mm)  
(inch)  
(mm)  
(inch)  
(mm)  
21  
13  
21  
24 /32 x 14 /32 x 19 /32  
626 x 366 x 499  
DIMENSION  
(W x H x D)  
7
17  
23  
25 /8 x 15 /32 x 16 /32  
SLEEVE DIMESION  
(W x H x D)  
OPTIONAL  
PART  
656 x 394 x 425  
20  
SLEEVE DEPTH  
WITH FRONT GRILLE  
510  
—5—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.4 FEATURES  
• Designed for cooling only.  
• Side air-intake, side cooled-air discharge.  
• Built in adjustable THERMISTOR and THERMOSTAT.  
• Washable one-touch filter.  
• Powerful and quiet cooling.  
• Top-down chassis for the simple installation and service.  
• Compact size.  
1.5 CONTROL LOCATIONS  
1.5.1 COOLING ONLY MODEL  
• OPERATION  
REMOTE CONTROL SIGNAL RECEIVER  
TEMPERATURE SETTING  
Use this button to automatically control the temperature of  
the room.  
The temperature can be set within a range of 60°F to 86°F by  
increments of 1°F.  
POWER  
To turn the air conditioner ON, push this button.  
To turn the air conditioner OFF, push the button again.  
This button takes priority over any other button.  
When you first turn it on, the unit is in cool mode, at High  
fan speed, and set at a temperature setting of 72°F.  
TIMER  
- SHUT-OFF TIME  
You will usually use shut-off time while you sleep.  
With unit running, use Timer to set number of hours until  
shut-off.  
For your sleeping comfort, once Time is set, the  
Temperature setting will raise 2°F after 30 min., and 2°F  
after another 30 min.  
Every time you push Timer button, it advances the Timer  
setting as follows: 1 Hour  
maximum.  
FAN SPEED  
Every time you push this button, it advances the setting as  
follows:  
{High ¡ Low ¡ Med ¡ High}  
....  
¡
2 Hours ¡¡ ¡ 12 Hours  
- START TIME  
With unit not running, use Timer to set number of hours  
before unit starts.  
Every time you push Timer button, it advances the Timer  
¡
.....  
setting as follows: 1 Hour  
maximum.  
¡
2 Hours  
¡
¡
12 Hours  
MODE  
-
Every time you push this button, the air conditioner alternates between COOL, MONEY SAVER® and FAN.  
- MONEY SAVER:  
The fan stops when the compressor stops cooling. Approximately every 3 minutes the fan will turn on and the unit will  
check the room air to determine if cooling is needed.  
• VENTILATION  
Push the lever to the "CLOSE" position to cool, heat or  
recirculate room air only.  
Pull the lever to the "OPEN" position to exhaust smoke or  
stale air from the room.  
This feature is best used in conjunction with the FAN ONLY  
PULL OPEN / PUSH CLOSE  
position.  
—6—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1.5.2 COOLING AND HEATING MODEL  
OPERATION  
Off  
- Turns the air conditioner off.  
Fan Only - The low fan speed operation without cooling (heating).  
Low Cool - Cooling with the low speed fan operation.  
High Cool - Cooling with the high speed fan operation.  
Low Heat - Heating with the low speed fan operation.  
High Heat - Heating with the high speed fan operation.  
Turn the Temperature Knob to the desired setting. The central position is a normal  
setting for average conditions. You can change this setting, if necessary, in  
accordance with your temperature preference.  
The thermostat automatically controls cooling or heating, but the fan runs  
continuously whenever the air conditioner is in operation. If the room is too warm,  
turn the thermostat control clockwise. If the room is too cool, turn the thermostat  
control counterclockwise.  
CAUTION  
A slight burning odor may come from the unit  
when first switching to HEAT after the cooling  
season is over. This odor, caused by fine dust  
particles on the heater, will disappear quickly.  
This is normal operation.  
When the air conditioner has been operating in the  
cooling or heating mode and is turned off or set to the fan  
only position, wait at least 3 minutes before resetting to  
the cooling operation again.  
7—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. DISASSEMBLY INSTRUCTIONS  
Prior to disassembling the unit, make sure that the POWER switch is set to OFF and the power cord is  
unplugged from the wall receptacle.  
2.1 MECHANICAL PARTS  
2.1.1 FRONT GRILLE  
1. Open the inlet grille downward.  
2. Remove the screw which fastens the front grille.  
3. Pull the front grille from the right side.  
4. Remove the front grille. (See Fig. 1)  
5. Re-install the component by referring to the  
removal procedure.  
Figure 1  
2.1.2 CABINET  
1. After disassembling the FRONT GRILLE, remove  
the 9 screws which fasten the cabinet at the both  
sides and the top. (See Fig. 2)  
Keep these for later use.  
Figure 2  
2.1.3 CONTROL BOX  
1. Remove the front grille. (Refer to section 2.1.1)  
2. Remove the screw which fasten the control  
box. (See Fig. 3)  
3. Pull the control box from the barrier.(See Fig.3)  
4. Discharge the capacitor by placing a 20,000 ohm  
resistor across the capacitor terminals.  
5. Disconnect two wire housings in the control box.  
6. Pull the control box forward completely.  
7. Re-install the components by referring to the  
removal procedure. (See Fig. 3)  
Figure 3  
(Refer to the circuit diagram found on pages  
29~30 in this manual and on the control box.)  
8—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2 AIR HANDLING PARTS  
2.2.1 ORIFICE, HEATER ASSY AND  
TURBO FAN  
1. Remove the front grille. (Refer to section 2.1.1)  
2. Remove the cabinet. (Refer to section 2.1.2)  
3. Remove the 2 screws which fasten the  
evaporator at the left side and the right side.  
(See Fig. 4)  
4. Move the evaporator sideward carefully.  
5. Remove the 2 terminals carefully  
(See Fig. 5, Electric Heater Model only)  
6. Remove the 4 screws which fasten the orifice.  
(See Fig. 5)  
Figure 4  
7. Remove the orifice. (See Fig. 5)  
Figure 5  
8. Using handheld pliers, remove the clamp which  
secures the turbo fan. (See Fig. 6)  
Figure 6  
9. Remove the turbo fan with pliers or your hand,  
without touching blades. (See Fig. 7)  
10. Re-install the components by referring to the  
removal procedures, above.  
Figure 7  
2.2.2 FAN  
1. Remove the cabinet. (Refer to section 2.1.2)  
2. Remove the brace and shroud cover.  
(Refer to section 2.2.1)  
3. Remove the 6 screws which fasten the condenser.  
4. Move the condenser sideways carefully.  
5. Using handheld pliers, remove the clamp which  
secures the fan.  
6. Remove the fan. (See Fig. 8)  
7. Re-install the components by referring to the  
removal procedures, above.  
Figure 8  
9—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.2.3 SHROUD  
1. Remove the fan. (Refer to section 2.2.2)  
2. Remove the screw which fastens the shroud.  
3. Remove the shroud. (See Fig. 9)  
4. Re-install the components by referring to the  
removal procedures, above.  
2.3 ELECTRICAL PARTS  
2.3.1 MOTOR  
1. Remove the cabinet. (Refer to section 2.1.2)  
2. Remove the clamp cord and disconnect the wire  
housing in control box. (Refer to section 2.1.3)  
3. Remove the turbo fan. (Refer to section 2.2.2)  
4. Remove the fan. (Refer to section 2.2.2)  
5. Remove the 4 or 2 screws which fasten the motor.  
(See Fig. 10)  
Figure 9  
6. Remove the motor.  
7. Re-install the components by referring to the  
removal procedures, above.  
Figure 10  
2.3.2 COMPRESSOR  
1. Remove the cabinet. (Refer to section 2.1.2)  
2. Discharge the refrigerant system using a FreonTM  
Recovery System.  
If there is no valve to attach the recovery system  
to, install one (such as a WATCO A-1) before  
venting the FreonTM . Leave the valve in place after  
servicing the system.  
3. Disconnect the 3 leads from the compressor.  
4. After purging the unit completely, unbraze the  
suction and discharge tubes at the compressor  
connections.  
5. Remove the 3 nuts and the 3 washers which  
fasten the compressor. (See Fig. 11)  
6. Remove the compressor.  
Figure 11  
7. Re-install the components by referring to the  
removal procedures, above.  
2.3.3 CAPACITOR  
1. Remove the control box. (Refer to section 2.1.3)  
2. Remove knobs and the tips which fasten the  
display panel.  
3. Disconnect the 2 leads from the rocker switch and  
remove the panel (Energy saver model only).  
4. Remove 2 screws and unfold the control box.  
(See Fig. 12)  
5. Remove the Rotary Switch.  
6. Remove the screw and the clamp which fastens  
the capacitor. (See Fig. 12)  
7. Disconnect all the leads on the capacitor terminals.  
8. Re-install the components by referring to the  
removal procedures, above.  
Figure 12  
10—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.3.4 POWER CORD  
1. Remove the control box. (Refer to section 2.1.3)  
2. Unfold the control box. (Refer to section 2.3.3)  
3. Disconnect the grounding screw from the control  
box.  
4. Disconnect 2 receptacles.  
5. Remove a screw which fastens the clip cord.  
6. Pull the power cord. (See Fig. 13)  
7. Re-install the components by referring to the  
removal procedure, above.  
(Use only one ground-marked hole, , for ground  
connection.)  
8. If the supply cord of this appliance is damaged, it  
must be replaced with the factory-authorized and  
specified cord.  
Figure 13  
2.3.5 THERMOSTAT  
1. Remove the control box. (Refer to section 2.1.3)  
2. Unfold the control box. (Refer to section 2.3.3)  
3. Remove the 2 screws which fasten the thermostat.  
4. Disconnect all the leads of thermostat terminals.  
5. Remove the thermostat. (See Fig. 14)  
6. Re-install the components by referring to the  
removal procedures, above.  
Figure 14  
2.3.6 ROTARY SWITCH  
1. Remove the control box. (Refer to section 2.1.3)  
2. Unfold the control box. (Refer to section 2.3.3)  
3. Remove 2 screws which fasten the rotary switch.  
4. Disconnect all the leads of the rotary switch  
terminals.  
5. Remove the rotary switch. (See Fig. 15)  
6. Re-install the components by referring to the  
removal procedure, above.  
Figure 15  
11—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2.4 REFRIGERATION CYCLE  
CAUTION  
TM  
Discharge the refrigerant system using a Freon  
Recovery System.  
If there is no valve to attach the recovery system,  
install one (such as a WATCO A-1) before  
TM  
venting the Freon . Leave the valve in place  
after servicing the system.  
2.4.1 CONDENSER  
1. Remove the cabinet. (Refer to section 2.1.2)  
2. Remove the brace and the shroud cover.  
(Refer to section 2.2.1)  
3. Remove the 5 screws which fasten the condenser.  
4. After discharging the refrigerant completely into a  
FreonTM Recovery System, unbraze the  
interconnecting tube at the condenser  
connections.  
Figure 16  
5. Remove the condenser.  
6. Re-install the components by referring to the notes  
on pages 13-14. (See Fig. 16)  
2.4.2 EVAPORATOR  
1. Remove the cabinet. (Refer to section 2.1.2)  
2. Discharge the refrigerant completely into a  
FreonTM Recovery System.  
3. Remove the 2 screws which fasten the evaporator  
at the left side and the right side.  
4. Move the evaporator sideward carefully and then  
unbraze the interconnecting tube at the evaporator  
connectors.  
Figure 17  
5. Remove the evaporator.  
6. Re-install the components by referring to the notes  
on pages 13-14. (See Fig. 17)  
2.4.3 CAPILLARY TUBE  
1. Remove the cabinet. (Refer to section 2.1.2)  
2. After discharging the refrigerant completely into  
a FreonTM Recovery System, unbraze the  
interconnecting tube at the capillary tube.  
3. Remove the capillary tube.  
4. Re-install the components by referring to the notes  
on page 13-14.  
12—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTES  
Replacement of the refrigeration cycle.  
1. When replacing the refrigeration cycle, be sure to  
discharge the refrigerant system using a FreonTM  
recovery System.  
6. Recharge as follows :  
1) Refrigeration cycle systems are charged from the  
High-side. If the total charge cannot be put  
in the High-side, the balance will be put in the  
suction line through the access valve which you  
installed as the system was opened.  
2) Connect the charging cylinder as shown in Fig. 18B.  
With valve C open, discharge the hose at the  
manifold connection.  
3) Open valve A and allow the proper charge to  
enter the system. Valve B is still closed.  
4) If more charge is required, the high-side will not  
take it. Close valve A.  
5) With the unit running, open valve B and add the  
balance of the charge.  
a. Do not add the liquid refrigerant to the Low-  
side.  
b. Watch the Low-side gauge; allow pressure to  
rise to 30 lbs.  
c. Turn off valve B and allow pressure to drop.  
d. Repeat steps B and C until the balance of the  
charge is in the system.  
If there is no valve to attach the recovery system,  
install one (such as a WATCO A-1) before venting  
the FreonTM. Leave the valve in place after  
servicing the system.  
2. After discharging the unit completely, remove the  
desired component, and unbrace the pinch-off  
tubes.  
3. Solder service valves into the pinch-off tube ports,  
leaving the valves open.  
4. Solder the pinch-off tubes with Service valves.  
5. Evacuate as follows.  
1) Connect the vacuum pump, as illustrated Fig.  
18A.  
2) Start the vacuum pump, slowly open manifold  
valves A and B with two full turns  
counterclockwise and leave the valves closed.  
The vacuum pump is now pulling through valves  
A and B up to valve C by means of the manifold  
and entire system.  
6) When satisfied the unit is operating correctly,  
use the pinch-off tool with the unit still running  
and clamp on to the pinch-off tube. Using a tube  
cutter, cut the pinch-off tube about 2 inches from  
the pinch-off tool. Use sil-fos solder and solder  
pinch-off tube closed. Turn off the unit, allow it to  
set for a while, and then test the leakage of the  
pinch-off connection.  
CAUTION  
If high vacuum equipment is used, just crack  
valves A and B for a few minutes, then open  
slowly with the two full turns counterclockwise.  
This will keep oil from foaming and being  
drawn into the vacuum pump.  
3) Operate the vacuum pump for 20 to 30 minutes,  
until 600 microns of vacuum is obtained. Close  
valves A and B, and observe vacuum gauge for  
a few minutes. A rise in pressure would  
indicate a possible leak or moisture remaining in  
the system. With valves A and B closed, stop  
the vacuum pump.  
4) Remove the hose from the vacuum pump and  
place it on the charging cylinder. See Fig. 18B.  
Open valve C.  
Discharge the line at the manifold connection.  
5) The system is now ready for final charging.  
13—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Equipment needed: Vacuum pump, Charging cylinder, Manifold gauge, Brazing equipment. Pinch-off tool  
capable of making a vapor-proof seal, Leak detector, Tubing cutter, Hand Tools to remove components, Service  
valve.  
COMPOUND GAUGE  
CONDENSER  
(HIGH PRESSURE SIDE)  
MANIFOLD  
GAUGE  
A
B
CAPILLARY TUBE  
SEE INSETS  
BELOW  
EVAPORATOR  
(LOW PRESSURE SIDE)  
COMPRESSOR  
HI  
LOW  
A
B
A
B
EXTERNAL  
VACUUM PUMP  
CHARGING  
CYLINDER  
C
Figure 18A-Pulling Vacuum  
Figure 18B-Charging  
14—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3. INSTALLATION  
INSTALLATION HARDWARE  
3.1 INSTALLATION REQUIREMENTS  
If you use an existing wall sleeve, you should measure its  
dimensions.  
2
1
4
5
Install the new air conditioner according to these installation  
instructions to achieve the best performance. All wall sleeves  
used to mount the new air conditioner must be in good  
structural condition and have a compatible rear grille in order  
to securely attach the new air conditioner. (FIG. 19A)  
With the FRIEDRICH USC sleeve, you can maintain the  
best performance of the new air conditioner. (FIG. 19B)  
2 Size options  
7
3
8
6
2 Size options  
19-21/32"  
(499 mm)  
24-21/32"  
(626 mm)  
ITEM NAME OF PARTS  
Q'TY  
1
2
3
4
5
6
7
8
PLASTIC GRILLE  
1
2
2
2
1
2
2
4
14-13/32"  
(366 mm)  
HORIZONTAL INSULATION STRIPS  
AROUND INSULATION STRIPS  
SUPPORT BLOCK  
BAFFLE  
18"(458 mm)  
TRIM FRAME  
Air Conditioner  
FIG. 19A  
SHIM  
PLASTIC NUTS AND WASHER SCREWS  
25-7/8  
"
(656 mm)  
CAUTION  
To avoid risk of personal injury, property damage, or  
product damage due to the weight of this device and sharp  
edges that may be exposed:  
15-17/32"  
(394 mm)  
Air conditioners covered in this manual pose an  
excessive weight hazard. Two or more people are  
Expanded  
aluminum metal grille  
16-23/32"  
(425 mm)  
needed  
to  
move  
and  
install  
the  
unit.  
To prevent injury or strain, use proper lifting and carrying  
techniques when moving unit.  
FRIEDRICH USC Wall Sleeve  
FIG. 20B  
Carefully inspect location where air conditioner will be  
installed. Be sure it will support the weight of the unit  
over an extended period of time.  
ELECTRICAL SERVICE  
Handle air conditioner with care. Wear protective gloves  
whenever lifting or carrying the unit. AVOID the sharp  
metal fins of front and rear coils.  
Check your available electrical service. The power supply  
available must be the same as that shown on the unit  
nameplate (found on left side of cabinet).  
Make sure air conditioner does not fall during installation.  
All models are equipped with a 3-prong service plug to  
provide proper service and safe positive grounding. Do not  
change plug in any way. Do not use an adapter plug. If your  
present wall outlet does not match your plug, call a qualified  
electrician to make the necessary corrections. SAVE  
CARTON for storage and this OWNER'S MANUAL for future  
reference. The carton is the best way to store unit during  
winter or when not in use.  
REQUIRED TOOLS:  
3/8-inch open end  
wrench or adjustable  
wrench  
1/4-inch hex socket  
and ratchet  
Tape measure  
Electric drill  
Tight Fitting gloves  
Standard screwdriver  
Phillips screwdriver  
Pliers  
Sharp knife  
1/4-inch drill bit  
15—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
NOTE: All wall sleeves used to mount the new Air  
Conditioner must be in sound structural condition and  
have a compatible rear grille that securely attaches to  
sleeve, or rear flange that serves as a stop for the Air  
Conditioner.  
3.2 INSTALLATION  
CAUTION  
We strongly recommend the removal of the  
old wall sleeve and the installation of a new  
FRIEDRICH USC Wall Sleeve.  
Remove old air conditioner from existing wall  
2
sleeve.  
If you decide to keep the existing wall sleeve,  
you have to redirect the louvers at the back of  
the wall sleeve illustration. The use of pliers is  
recommended. If you DO NOT redirect, you run  
the risk of poor performance or product failure.  
This is not covered under the terms of the  
FRIEDRICH warranty.  
Clean the interior of an existing sleeve.  
(Do not disturb existing seals or gaskets.)  
3
Wall sleeve must be securely fastened in wall  
4
before installing the air conditioner. Use the nails  
or screws through the sides of the sleeve into wall,  
if needed. Repaint sleeve if needed.  
Prepare the wall sleeve for installation of the unit.  
5
If you plan to use your existing wall sleeve, and it  
is not the FRIEDRICH USC sleeve, use procedure  
B or C below.  
Pick a location which will allow the conditioned air to  
blow into the area you want. Good installation with  
special attention to the proper position of the unit will  
lessen the chance that service will be needed.  
Procedure Brand  
Depth(inches)  
16-23/32  
A
FRIEDRICH USC  
ITEMS IN INSTALLATION HARDWARE  
You may not need all parts in the kit. Discard unused  
parts  
White-Westinghouse  
Frigidaire Carrier  
(52F series)  
16, 17-1/2  
or 22  
ITEM (inches)  
263/ x 161/  
Qty.  
1
1
1
1
1
2
1
2
General Electric  
/Hotpoint  
B
Plastic grille  
4
2
16-7/8  
13/ x 5/ x 273/  
8
8
16  
Horizontal Insulation Strips  
Whirlpool  
17-1/8 or 23  
13/ x 13/ x 273/  
8
8
16  
2
13/ x 3/ x 611/  
Carrier (51S series)  
18-5/8  
16-3/4  
or 19-3/4  
15  
8
4
2
Around Insulation Strips  
13/ x 13/ x 611/  
8
8
Fedders/Emerson  
Emerson/Fedders  
Support Block  
Baffle  
13/ x 13/ x 45/  
4
8
16  
C
14 x 41/2 x 1  
/
8
Shim  
13 x 1 x 3  
/
4
Trim Frame  
Washer Screw  
Nuts(Plastic)  
2
4
4
6
Install new unit into wall sleeve.  
CAUTION: When installation is completed,  
replacement unit MUST have a rearward slope as  
shown.  
HOW TO INSTALL  
Before installing the unit, identify the existing wall sleeve  
from the list below.  
1
UNIT  
Wall Sleeve  
Wall Sleeve Dimensions (inches)  
Brand  
Width  
Height  
Depth  
White-Westinghouse  
Frigidaire  
Carrier (52F series)  
General Electric  
/Hotpoint  
16, 17-1/2  
or 22  
FRONT  
1/4"  
25-1/2 15-1/4  
26 15-5/8  
25-7/8 16-1/2  
27 16-3/4  
16-7/8  
17-1/8  
or 23  
16-3/4  
Whirlpool  
FIG. 20  
Fedders/Emerson  
Friedrich WSC  
or 19-3/4  
FRIEDRICH USC  
Emerson/Fedders  
25-7/8 15-17/32 16-23/32  
26-3/4 15-3/4  
15  
Carrier (51S Series) 25-3/4 16-7/8  
18-5/8  
16—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install the new unit into the wall sleeve.  
3.3 PROCEDURE A  
4
5
If you are using a new USC sleeve in conjunction  
1
To assemble trim, snap the tab of each piece into  
the slot of the other piece as shown below. Slide  
trim over the front of the air conditioner until trim is  
flush with sleeve as shown below.  
with your unit, skip to step 3. Otherwise, install the  
plastic grille from the kit. Cut the plastic grille to fit  
the rear opening of the existing sleeve. Place the  
plastic grille to the inside of the wall sleeve at the  
rear flange.  
Trim (2 ea)  
FIG. 21  
Fasten the 4 washer screws to secure the grille to  
2
Wall  
the wall sleeve. If you need plastic nuts to mount  
plastic grille to the inside of the wall sleeve, there  
are plastic nuts in the installation kit. The nuts are  
installed from the inside of the sleeve and are  
pressed into the square holes of the rear flanges.  
FIG. 24  
or  
FIG. 22  
CAUTION  
Ensure that the inside of the sleeve is thoroughly  
3
Air conditioners covered in this manual pose  
an excessive weight hazard. Two or more  
people are needed to move and install the  
unit.  
clean. Remove the backing from the Horizontal  
Insulation strip 13/ x 3/ x 273/16 and attach that to  
8
8
the inside bottom of the sleeve as shown below.  
Remove the backing from the Around Insulation  
strip 13/ x 3/ x 611/ and attach that to the inside  
8
4
2
To prevent injury or strain, use proper lifting  
and carrying techniques when moving unit.  
When handling the air conditioner, be careful  
to avoid cuts from sharp metal fins on front  
and rear coils.  
front of the sleeve as shown below.  
Around Insulation  
Make sure air conditioner does not fall during  
removal.  
Horizontal Insulation  
FIG. 23  
17—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remove the backing from the Horizontal Insulation  
strip 13/ x 5/ x 273/16 and attach that to the inside  
3.4 PROCEDURE B  
4
8
8
Redirect the louvers at the back of the wall sleeve  
to 60° angle as shown in the FIG 25. The use of  
1
bottom of the sleeve as shown below. Remove the  
backing from the Around Insulation strip 13/ x 3/ x  
8
4
pliers is recommended.  
611/ and attach that to the inside front of the  
2
sleeve as shown below.  
7 5  
/
"
16  
60°  
60°  
Rear Louvers  
Around Insulation  
(Top View)  
Horizontal Insulation  
FIG. 25  
FIG. 28  
If the wall sleeve already has a rear grille, skip to  
step 4. If the wall sleeve does not have a rear grille  
or louvered panel, install the plastic grille from the  
kit. Cut the plastic grille to 25-1/2" wide and 15-1/4"  
high. Place the plastic grille to the inside of the wall  
sleeve at the rear flange.  
2
If the depth of your existing wall sleeve is less than  
or equal to 18", skip to step 7. Otherwise, cut the  
baffles and the support blocks according to length  
"A" in the table below.  
5
A
Length "A"  
(inches)  
Depth"D" of the existing  
wall sleeve (inches)  
Support  
Block  
18-5/8  
3/4  
1-3/4  
4
18  
D
18-5/8  
D
19-3/4  
Baffle  
19-3/4  
D
22  
A
FIG. 29  
Remove the backing from the support blocks and  
attach them to the inside of the wall sleeve as  
shown FIG 30. Slide the baffle into slots of the  
support blocks.  
6
Place the plastic grille  
FIG. 26  
Fasten the 4 washer screws to secure the grille to  
the wall sleeve. If you need plastic nuts to mount  
plastic grille to the inside of the wall sleeve, there  
are plastic nuts in the installation kit. The nuts are  
installed from the inside of the sleeve and are  
pressed into the square holes of the rear flanges.  
3
(7 5/16")  
Wall  
Baffle  
Wall  
Sleeve  
Front  
Support  
Block  
or  
FIG. 30  
FIG. 27  
Fasten the screws  
Install the new unit into the wall sleeve.  
7
18—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
PROCEDURE B  
To assemble trim, snap the tab of each piece into  
8
the slot of the other piece as shown below. Slide  
trim over the front of the air conditioner until trim is  
flush with sleeve as shown below.  
Trim (2 ea)  
Wall  
FIG. 31  
CAUTION  
Air conditioners covered in this manual pose  
an excessive weight hazard. Two or more  
people are needed to move and install the unit.  
To prevent injury or strain, use proper lifting  
and carrying techniques when moving unit.  
When handling the air conditioner, be careful  
to avoid cuts from sharp metal fins on front  
and rear coils.  
Make sure air conditioner does not fall during  
removal.  
19—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Remove the backing from the Horizontal Insulation  
strip 13/ x 13/ x 273/16 and attach that to the inside  
3.5 PROCEDURE C  
4
8
8
Redirect the louvers at the back of the wall sleeve  
to 60° angle as shown in the FIG 32. The use of  
1
bottom of the sleeve as shown below. Remove the  
backing from the Around Insulation strip 13/ x 13/ x  
8
8
pliers is recommended.  
611/ and attach that to the inside front of the  
2
sleeve as shown below.  
7 13  
/
"
16  
60°  
60°  
Rear Louvers  
Around Insulation  
(Top View)  
Horizontal Insulation  
FIG. 32  
If the wall sleeve already has a rear grille, skip to  
step 4. If the wall sleeve does not have a rear grille  
or louvered panel, install the plastic grille from the  
kit. Cut the plastic grille to 26-1/2" wide and 15-1/2"  
high. Place the plastic grille to the inside of the wall  
sleeve at the rear flange.  
FIG. 35  
2
If the depth of your existing sleeve is less than or  
equal to 18, skip to step 7. Otherwise, cut the  
baffles and the support blocks according to Length  
"A" in the table below.  
5
A
Length "A"  
(inches)  
Depth"D" of the existing  
wall sleeve (inches)  
Support  
Block  
18-5/8  
3/4  
1-3/4  
4
18  
D
18-5/8  
D
19-3/4  
Baffle  
19-3/4  
D
22  
A
FIG. 36  
Remove the backing from the support blocks and  
attach them to the inside of the wall sleeve as  
shown FIG 37. Slide the baffle into slots of the  
support blocks  
Place the plastic grille  
FIG. 33  
6
Fasten the 4 washer screws to secure the grille to  
the wall sleeve. If you need plastic nuts to mount  
plastic grille to the inside of the wall sleeve, there  
are plastic nuts in the installation kit. The nuts are  
installed from the inside of the sleeve and are  
pressed into the square holes of the rear flanges.  
3
(7 13/16")  
Wall  
Baffle  
Wall  
Sleeve  
Front  
Support  
Block  
or  
FIG. 34  
FIG. 37  
Fasten the screws  
20—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
To assemble trim, snap the tab of each piece into  
the slot of the other piece as shown below. Slide  
trim over the front of the air conditioner until trim is  
flush with sleeve as shown below.  
PROCEDURE C  
9
Remove the backing from the 13" shim strips and  
7
attach them as shown below in Fig. 39. The higher  
portion of shim is to be placed in front of the rib on  
the base of wall sleeve.  
1" high  
3/4" High  
FIG. 38  
Trim (2 ea)  
Shim (2EA)  
Wall  
6"  
6"  
FIG. 39  
Install the new unit into the wall sleeve  
8
FIG. 40  
CAUTION  
Air conditioners covered in this manual pose an  
excessive weight hazard. Two or more people  
are needed to move and install the unit.  
To prevent injury or strain, use proper lifting and  
carrying techniques when moving unit.  
When handling the air conditioner, be careful to  
avoid cuts from sharp metal fins on front and  
rear coils.  
Make sure air conditioner does not fall during  
removal.  
21—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3.4 ELECTRICAL REQUIREMENTS  
3.4.1 ELECTRICAL DATA (FOR 115V MODEL)  
Line Cord Plug  
Use Wall Receptacle  
Power Supply  
Do not under any  
circumstances cut  
or remove the  
grounding prong  
from the plug.  
Use 15 AMP time  
delay fuse or 15 AMP  
circuit breaker.  
Parallel  
type  
Power supply cord with  
3-prong grounding plug  
Standard 125V, 3-wire grounding  
receptacle rated 15A, 125V AC  
USE OF EXTENSION CORDS  
Because of potential safety hazards, we strongly discourage the use of an extension cord. However, if you wish  
to use an extension cord, use a CSA certified/UL-listed 3-wire (grounding) extension cord, rated 15A, 125V.  
3.4.2 ELECTRICAL DATA (FOR 230/208V MODEL)  
Line Cord Plug  
Use Wall Receptacle  
Power Supply  
Do not under any  
circumstances cut  
or remove the  
grounding prong  
from the plug.  
Use 15 AMP  
time delay fuse or  
circuit breaker.  
Tandem  
type  
Power supply cord with  
3-prong grounding plug  
Standard 250V, 3-wire grounding  
receptacle rated 15A, 250V AC  
Do not under any  
circumstances cut  
or remove the  
grounding prong  
from the plug.  
Use 20 AMP  
time delay fuse or  
circuit breaker.  
Perpendicular  
type  
Refer to the nameplate  
Power supply cord with  
3-prong grounding plug  
Standard 250V, 3-wire grounding for correct fusing.  
receptacle rated 20A, 250V AC  
All wiring should be made in accordance with local electrical codes and regulations.  
NOTE : Aluminum house wiring may pose special problems. Consult a qualified electrician.  
3.4.3 ELECTRICAL SAFETY  
IMPORTANT GROUNDING INSTRUCTIONS  
Air conditioner has a three-prong grounding plug on its power supply cord, which must be plugged into properly grounded  
three-prong wall receptacle for your protection against possible shock hazard.  
FUSE Use a time-delay fuse or circuit breaker. Refer to the nameplate for proper power supply requirements.  
208, 230, and 208/230 VOLT UNITS  
These units are equipped with a three-prong grounding plug on the power supply cord, which must be plugged into a matching  
properly grounded three-prong wall receptacle for your protection against possible shock hazard. If such an outlet is not  
present, one must be installed by a qualified electrician in accordance with the National Electrical Code and local codes and  
ordinances.  
NOTE: DO NOT USE AN EXTENSION CORD on 208, 230, and 208/230 Volt units.  
22—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4. TROUBLESHOOTING GUIDE  
4.1 OUTSIDE DIMENSIONS  
24-21/32"  
19-21/32"  
(626mm)  
(499mm)  
4.2 PIPING SYSTEM  
CONDENSER COILS  
FAN  
CAPILLARY TUBE  
COMPRESSOR  
MOTOR  
TURBO FAN  
EVAPORATOR COILS  
: REFRIGERANT FLOW  
Following is a brief description of the important components and their functions in the refrigeration system.  
Refer to Fig. 41 to follow the refrigeration cycle and the flow of the refrigerant in the cooling cycle.  
ROOM AIR CONDITIONER  
CYCLE OF REFRIGERATION  
EVAPORATOR COILS  
CONDENSER COILS  
VAPOR INLET  
SUCTION LIME  
COOL LOW PRESSURE VAPOR  
HOT  
DISCHARGED  
AIR  
COMPLETE LIQUID  
BOIL OFF POINT  
COOLED  
AIR  
ROOM AIR HEAT LOAD  
OUTSIDE COOLING  
AIR FOR REFRIGERANT  
PASS THROUGH  
MOTOR  
COMPRESSOR  
OIL  
LIQUID  
PRESSURE  
DROP  
LIQUID OUTLET  
HIGH PRESSURE VAPOR  
(LIQUID REFRIGERANT)  
LIQUID PEFRIGERANT  
CAPILLARY TUBE  
LOW PRESSURE VAPOR  
Figure 41  
23—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4.3 TROUBLESHOOTING GUIDE  
In general, possible trouble is classified in two causes.  
The one is called Starting Failure which is caused from an electrical defect, and the other is Ineffective Air  
Conditioning caused by a defect in the refrigeration circuit and improper application.  
Unit is running but cooling is ineffective  
Ineffective Cooling  
Check cold air circulation  
for smooth flow.  
Check outdoor coil  
(heat exchanger) & the fan  
operation.  
Check heat load increase.  
Unexpected residue  
Overloaded Circuit  
Dirty indoor coil  
(Heat exchanger)  
Check gas leakage.  
Repair gas leak.  
Malfunction of fan  
Clogged air filter  
Check inside gas pressure.  
Replacement of unit if the  
unit is beyond repair.  
Obstruction at air outlet  
Adjusting of refrigerant  
charge  
Stop auto air-swing  
Malfunction of compressor  
Correct above troubles  
Replacement of  
compressor  
Check clogging in  
refrigeration circuit.  
Satisfactory operation with  
temperature difference of  
inlet & outlet air ; 44.6~50˚F  
Repair clogging in  
refrigeration circuit.  
24—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fails to Start  
Check power source.  
Check circuit breaker  
and fuse.  
Check control switch  
setting.  
Gas leakage at feeler bulb  
of thermostat  
Check control switch.  
Only compressor fails to  
start.  
Only fan fails to start.  
Improper wiring.  
Drop in power voltage.  
Improper thermostat setting  
Defect of fan motor  
capacitor.  
Defective compressor  
capacitor.  
Loose terminal connection.  
Improper wiring  
Irregular motor resistance  
(
).  
Irregular motor insulation  
).  
Check capacitor.  
Replacement.  
(
Replacement of fan motor  
Regular but fails to start  
Irregular motor resistance ( )  
Irregular motor insulation ( )  
Replacement of compressor  
(locking of rotor, metal)  
Replacement of compressor  
(Motor damaged)  
25—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPLAINT  
CAUSE  
REMEDY  
Fan motor will not run.  
No power  
Check voltage at outlet. Correct if none.  
Power supply cord  
Rotary switch  
Check voltage to rotary switch. If none, check  
power supply cord. Replace cord if circuit is open.  
Check switch continuity. Refer to wiring diagram  
for terminal identification. Replace switch if  
defective.  
Wire disconnected or  
connection loose  
Connect wire. Refer to wiring diagram for terminal  
identification. Repair or replace loose terminal.  
Capacitor (Discharge  
Test capacitor.  
capacitor before testing.)  
Replace if not within ±10% of manufacturer's  
rating. Replace if shorted, open, or damaged.  
Will not rotate  
Fan blade hitting shroud or blower wheel hitting  
scroll. Realign assembly.  
Units using slinger ring condenser fans must  
have 1/4 to 5/16 inch clearance to the base. If it is  
hitting the base, shim up the bottom of the fan  
motor with mounting screw(s).  
Check fan motor bearings; if motor shaft will not  
rotate, replace the motor.  
Fan motor runs  
intermittently  
Revolves on overload.  
Check voltage. See limits on page 27. If not within  
limits, call an electrician.  
Test capacitor.  
Check bearings. Does the fan blade rotate freely?  
If not, replace fan motor.  
Pay attention to any change from high speed to  
low speed. If the speed does not change, replace  
the motor.  
Fan motor noise.  
Grommets  
Fan  
Check grommets; if worn or missing, replace them.  
If cracked, out of balance, or partially missing,  
replace it.  
Turbo fan  
If cracked, out of balance, or partially missing,  
replace it.  
Loose set screw  
Worn bearings  
Tighten it.  
If knocking sounds continue when running or  
loose, replace the motor. If the motor hums or  
noise appears to be internal while running,  
replace motor.  
26—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
COMPLAINT  
CAUSE  
REMEDY  
Compressor will not run,  
but fan motor runs.  
Voltage  
Wiring  
Check voltage. See the limits on the preceding.  
page. If not within limits, call an electrician.  
Check the wire connections, if loose, repair or  
replace the terminal. If wires are off, refer to wiring  
diagram for identification, and replace. Check wire  
locations. If not per wiring diagram, correct.  
Rotary  
Check for continuity, refer to the wiring diagram  
for terminal identification. Replace the switch if  
circuit is open.  
Thermostat  
Check the position of knob If not at the coldest  
setting, advance the knob to this setting and  
restart unit.  
Check continuity of the thermostat. Replace  
thermostat if circuit is open.  
Capacitor (Discharge  
capacitor before  
servicing.)  
Check the capacitor.  
Replace if not within ±10% of manufacturers  
rating. Replace if shorted, open, or damaged.  
Check the compressor for open circuit or  
ground. If open or grounded, replace the  
compressor.  
Compressor  
Overload  
Check the compressor overload, if externally  
mounted. Replace if open. (If the compressor  
temperature is high, remove the overload, cool it,  
and retest.)  
ROOM AIR CONDITIONER VOLTAGE LIMITS  
NAME PLATE RATING  
MINIMUM  
MAXIMUM  
126.5V  
253V  
115V  
103.5V  
187V  
208/230V  
27—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
REMEDY  
COMPLAINT  
CAUSE  
Compressor cycles  
on overload.  
Voltage  
Check the voltage. See the limits on the preced-  
ing page. If not within limits, call an electrician.  
Overload  
Check overload, if externally mounted.  
Replace if open. (If the compressor temperature  
is high, remove the overload, cool, and retest.)  
Fan motor  
If not running, determine the cause. Replace if  
required.  
Condenser air flow  
restriction  
Remove the cabinet. inspect the interior surface  
of the condenser; if restricted, clean carefully  
with a vacuum cleaner (do not damage fins) or  
brush. Clean the interior base before  
reassembling.  
Condenser fins  
(damaged)  
If condenser fins are closed over a large area  
on the coil surface, head pressures will increase,  
causing the compressor to cycle. Straighten the  
fins or replace the coil.  
Capacitor  
Test capacitor.  
Wiring  
Refrigerating system  
Air filter  
Check the terminals. If loose, repair or replace.  
Check the system for a restriction.  
If restricted, clean of replace.  
Insufficient cooling or  
heating  
Exhaust damper door  
Unit undersized  
Close if open.  
Determine if the unit is properly sized for the area to  
be cooled.  
Excessive noise.  
Blower or fan  
Copper tubing  
Check the set screw or clamp. If loose or missing,  
correct. If the blower or fan is hitting air guide,  
rearrange the air handling parts.  
Remove the cabinet and carefully rearrange tubing  
not to contact cabinet, compressor, shroud, and  
barrier.  
28—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5. SCHEMATIC DIAGRAM  
5.1 CIRCUIT DIAGRAM  
MODEL : BD-81/BD-101/BD-123  
CN-AC/DC  
CN-AC/DC  
CN-MOTOR  
1
BK  
BL  
RD  
YL  
OR  
GN/YL  
(
)
GN  
MOTOR  
DC PCB  
ASSEMBLY  
CAPACITOR  
YL  
2
F
3
4
TRANS  
(SMPS)  
C
H
(
)
OR BR  
THERMISTOR  
BK  
CN-PWR  
CN-TH1  
RD  
SWITCH  
DC12V  
CN-12V  
(
)
)
WH BL  
FUSE  
250V/T2A  
(
Ribbed  
(115V/T2A)  
(
)
BK BR  
H.V.  
6
5
(
)
CN-HVB  
Plain  
ASSEMBLY  
3
4
GN/YL  
(
)
GN  
RY-COMP  
BK  
RD  
R
S
COMP.  
AC PCB  
ASSEMBLY  
BL  
C
OLP  
AIR FILTER  
ASSEMBLY  
7
WIRING DIAGRAM  
3854A20407A  
PART NO.  
Q'TY  
RE-  
NO.  
DESCRIPTION  
PER SET MARKS  
BD-81  
BD-101  
BD-123  
6411A20028A  
4681A20044H  
6120AR2194F  
6411A20028C  
4681A20044F  
6120AR2194K  
6322AQ9189F  
2520UKCC2CA  
6750U-L031A  
6411A20028B  
4681A20041C  
6120AR2194D  
1
2
3
4
5
6
1
1
1
1
1
1
POWER CORD  
FAN MOTOR  
CAPACITOR  
THERMISTOR  
5416A90007D  
6750A30001N  
2520UKHK2CA  
6750U-058A  
COMPRESSOR  
OVERLOAD PROTECTOR  
29—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
MODEL : BDE-103/BDE-123  
POWER INPUT  
GN/YL  
1
3
BK(BR)  
(Plain)  
WH(BL)  
(Ribbed)  
ROTARY SWITCH  
8
6
4
2
RD  
BL  
7
1
BL  
BK  
L
2
H
BK  
MOTOR  
OR(BR)  
CAPACITOR  
F
YL  
YL  
OR(BR)  
C
THERMOSTAT  
WH  
BK  
4
5
C
H
L
C
H
BK  
RD  
BK  
RD  
R
S
7
COMP  
BL  
BL  
BR(YL)  
C
O.L.P  
RD  
RD  
6
8
FUSE LINK  
HEATER  
BI-METAL  
THERMOSTAT  
WIRING DIAGRAM  
3854AR3563D  
PART NO.  
Q'TY  
RE-  
NO.  
DESCRIPTION  
POWER CORD  
PER SET MARKS  
BDE-103  
BDE-123  
2H00677U  
2H00598F  
1
2
3
4
5
6
7
8
1
1
1
1
1
1
1
1
ROTARY SWITCH  
FAN MOTOR  
4681A20044E  
4681A20041C  
6120AR2359E  
2H01127D  
CAPACITOR  
THERMOSTAT  
2520UKCK2BA  
6750U-L028A  
2520UKHK2CA  
6750U-L058A  
COMPRESSOR  
OVERLOAD PROTECTOR  
ELECTRIC HEATER  
5300A20003A  
30—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. EXPLODED VIEW  
• MODEL: BD-81/BD-101/BD-123/BDE-103/BDE-123  
130900  
749180  
E
G
147582-1  
135500  
268714  
147582-2  
263230  
147581  
268712  
237200  
238310  
C
o
o
y
l
E
n
er  
g
Sa  
v
er  
F
a
n
F1  
F2  
LO  
152302  
135313  
M
W
F
3
H
I
E
D
GH  
T
im  
e
F
r
M
O
D
TEM  
E
P
T
IM  
E
R
F
A
N
435301  
S
P
E
ED  
P
264110  
135312  
352390  
349480  
D
559010  
267110  
349001  
W0CZZ  
148000  
753010  
354210  
F
753011  
W48602  
149980  
346811  
554031  
130410  
349600  
359012  
249950  
W48602  
A
C
B
269310  
266003  
35211A  
352113  
567502  
137215  
554160  
550140  
264110  
352115  
W0CZZ  
149410  
552111  
—31—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7. REPLACEMENT PARTS LIST  
MODEL: BD-81/BD-101  
R: Service Parts  
N: Non Service parts  
PART NO.  
LOCATION  
DESCRIPTION  
REMARK  
NO  
.
BD-81  
BD-101  
G
249950 CONTROL BOX ASSY, SINGLE  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
4995A10089G  
4995A10089H  
268714  
268712  
PWB(PCB) ASSEMBLY, MAIN(AC)  
PWB(PCB) ASSEMBLY, MAIN(DC)  
6871A20343C  
6871A20344C  
264110 POWER CORD ASSY  
263230 THERMOSTAT ASSY  
W0CZZ CAPACITOR, DRAWING  
267110 REMOTE, CONTROLLER  
237200 PANEL ASSY, CONTROL  
554160 COMPRESSOR  
6411A20028C  
6411A20028C  
6322AQ9189F  
6120AR2194K  
6120AR2194P  
6727A90001A  
3720A10128A  
B
C
2520UAFC2AC  
2520UKCC2CA  
550140 ISOLATOR, COMP  
567502 O.L.P  
4H00982E  
6750U-L005A  
5211A30588C  
5211A20289C  
-
6750U-L031A  
5211A30588E  
5211A20289D  
-
352113  
352115  
TUBE ASSY, DISCHARGE SINGLE  
TUBE ASSY, EVAPORATOR IN  
352115-1 TUBE ASST, EVAPORATOR IN  
35211A TUBE ASSY, SUCTION SINGLE  
552111 TUBE ASSY, CAPILLARY  
352390 AIR GUIDE ASSY  
349001 DAMPER,VENTILATION  
135312 GRILLE ASSY, FRONT  
135313 GRILLE, INLET  
5211A20498A  
5211A20214N  
5211A20494C  
5211A20214L  
D
E
5239A10002E  
4900A20001A  
3531A20121A  
3530A20053A  
4758A20008B  
4758A20009A  
4758A20009B  
5230A20007A  
4948A10006A  
4998A10007B  
147581 LOUVER, HORIZONTAL  
147582-1 LOUVER, VERTICAL  
147582-2 LOUVER, VERTICAL  
152302 FILTER(MESH), A/C  
349480 ORIFICE  
149980 SHROUD  
346811 MOTOR ASSY, SINGLE  
349600 MOUNT, MOTOR  
148000 BRACE  
4681A20044G  
4681A20044F  
4960A20005A  
4800A30002A  
3530A30002A  
5421A20071E  
5900A20009A  
5403A20040P  
5900AR1173A  
3H02932B  
435301 GRILLE, REAR  
354210 EVAPORATOR ASSY, FIRST  
359012 FAN, TURBO  
554031 CONDENSER ASSY, BENT  
559010 FAN ASSY, AXIAL  
W48602 CLAMP, SPRING  
130410 BASE ASSY, SINGLE  
130900 CABINET  
3041A10014X  
3041A10014V  
3090A20003B  
4918A20001A  
749180 TRIM  
32—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R: Service Parts  
N: Non Service parts  
MODEL: BD-123  
PART NO.  
BD-123  
LOCATION  
DESCRIPTION  
REMARK  
NO  
.
G
249950 CONTROL BOX ASSY, SINGLE  
4995A10089L  
6871A20343D  
6871A20344C  
6411A20028B  
6322AQ9189F  
6120AR2194D  
6727A90001A  
3720A10128A  
2520UKHK2CA  
4H00982E  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
268714  
268712  
RPWB(PCB) ASSEMBLY, MAIN(AC)  
PWB(PCB) ASSEMBLY, MAIN(DC)  
264110 POWER CORD ASSY  
263230 THERMOSTAT ASSY  
W0CZZ CAPACITOR, DRAWING  
267110 REMOTE CONTROLLER  
237200 PANEL ASSY, CONTROL  
554160 COMPRESSOR  
B
C
550140 ISOLATOR, COMP  
567502 O.L.P  
6750U-L058A  
5211A30588A  
5211A20904A  
5211A20904B  
5211A30587A  
5211A20214K  
5239A10002E  
4900A20001A  
3531A20121A  
3530A20053A  
4758A20008B  
4758A20009A  
4758A20009B  
5230A20007A  
4948A10006A  
4998A10007B  
4681A20041C  
4960A20008A  
4800A30002A  
3530A30002A  
5421A20060A  
5900A20009A  
5403A20040H  
5900AR1173A  
3H02932B  
352113  
352115  
TUBE ASSY, DISCHARGE SINGLE  
TUBE ASSY, EVAPORATOR IN  
352115-1 TUBE ASST, EVAPORATOR IN  
35211A TUBE ASSY, SUCTION SINGLE  
552111 TUBE ASSY, CAPILLARY  
352390 AIR GUIDE ASSY  
349001 DAMPER VENTILATION  
135312 GRILLE ASSY, FRONT  
135313 GRILLE, INLET  
D
E
147581 LOUVER, HORIZONTAL  
147582-1 LOUVER, VERTICAL  
147582-2 LOUVER, VERTICAL  
152302 FILTER(MESH), A/C  
349480 ORIFICE  
149980 SHROUD  
346811 MOTOR ASSY, SINGLE  
349600 MOUNT, MOTOR  
148000 BRACE  
435301 GRILLE, REAR  
354210 EVAPORATOR ASSY, FIRST  
359012 FAN, TURBO  
554031 CONDENSER ASSY, BENT  
559010 FAN ASSY, AXIAL  
W48602 CLAMP, SPRING  
130410 BASE ASSY, SINGLE  
130900 CABINET  
3041A10014T  
3090A20003B  
4918A20001A  
749180 TRIM  
33—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R: Service Parts  
N: Non Service parts  
MODEL: BDE-103/BDE-123  
PART NO.  
LOCATION  
DESCRIPTION  
REMARK  
NO  
.
BDE-103  
BDE-123  
A
249950  
264110  
266003  
269310  
W0CZZ  
149410  
137215  
554160  
550140  
567502  
352113  
352115  
CONTROL BOX ASSY, SINGLE  
POWER CORD ASSY  
SWITCH, ROTARY  
4995A20131V  
2H00677U  
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
R
2H00598F  
THERMOSTAT ASSY  
CAPACITOR, DRAWING  
KNOB ASSY  
2H01127D  
6120AR2359E  
4941A30005B  
3721A20049F  
PANEL ASSY, CONTROL  
COMPRESSOR  
B
C
2520UKCK2BA  
2520UKHK2CA  
ISOLATOR, COMP  
4H00982E  
O.L.P  
6750U-L028A  
5211A30588B  
5211A20289C  
-
6750U-L058A  
5211A30588A  
5211A20904A  
5211A20904B  
5211A30587A  
5211A20214K  
TUBE ASSY, DISCHARGE SINGLE  
TUBE ASSY, EVAPORATOR IN  
352115-1 TUBE ASST, EVAPORATOR IN  
35211A  
552111  
352390  
349001  
135312  
135313  
147581  
TUBE ASSY, SUCTION SINGLE  
TUBE ASSY, CAPILLARY  
AIR GUIDE ASSY  
5211A20498B  
5211A20214L  
D
E
5239A10002F  
4900A20001A  
3531A20121B  
3530A20053A  
4758A20008B  
4758A20009A  
4758A20009B  
5230A20007A  
5301A20011A  
5300A20003A  
4948A10006A  
4998A10007B  
DAMPER,VENTILATION  
GRILLE ASSY, FRONT  
GRILLE, INLET  
LOUVER, HORIZONTAL  
147582-1 LOUVER, VERTICAL  
147582-2 LOUVER, VERTICAL  
152302  
753010  
753011  
349480  
149980  
346811  
349600  
148000  
435301  
354210  
359012  
554031  
559010  
W48602  
130410  
130900  
749180  
FILTER(MESH), A/C  
HEATER ASSY  
F
HEATER ASSY, ELECTRIC  
ORIFICE  
SHROUD  
MOTOR ASSY, SINGLE  
MOUNT, MOTOR  
BRACE  
4681A20044E  
4960A20005A  
4800A30002A  
3530A30007A  
5421A20071E 5421A20060A  
5900A20009B  
5403A20040P 5403A20040H  
4681A20041C  
4960A20008A  
GRILLE, REAR  
EVAPORATOR ASSY, FIRST  
FAN, TURBO  
CONDENSER ASSY, BENT  
FAN ASSY, AXIAL  
CLAMP, SPRING  
BASE ASSY, SINGLE  
CABINET  
5900AR1173A  
3H02932B  
3041A10014V  
3041A10014T  
3090A20003B  
4918A20001A  
TRIM  
34—  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Specifications and performance data subject to change without notice.  
HEAT CONTROLLER, INC.  
1900 WELLWORTH AVENUE JACKSON, MICHIGAN 49203  
THE QUALITY LEADER IN CONDITIONING AIR  
P/No.: 3828A20040D  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Impact Driver H0582 User Manual
GSI Outdoors Clothes Dryer PNEG 951 User Manual
Hamilton Beach Slow Cooker 33969 User Manual
Harbor Freight Tools Thermometer 94233 User Manual
Honeywell Barcode Reader 9520 40 User Manual
Hoshizaki Ice Maker F 801MAH C User Manual
Hotpoint Range RGB790DEP User Manual
HP Hewlett Packard Computer Drive BC745A User Manual
HP Hewlett Packard Personal Computer 120 113 User Manual
HP Hewlett Packard Personal Computer VS825UT User Manual