Hearth and Home Technologies Ventilation Hood TR342 User Manual

Installation  
Instructions  
TM  
Models:  
TR342, TR344, TV342  
Round Termination Cap and  
Storm Collar  
These chimney termination caps have been tested for use with specific Hearth & Home Technologies inc. fireplaces and  
are UL listed as fireplace parts. Refer to the installation instructions supplied with the fireplace for the correct accessories  
to be used. Check with your local building code agency before you begin installation to ensure compliance with local codes,  
including the need for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you  
need clarification of any of the instructions contained here, contact the Heatilator Technical Services Dept., Hearth & Home  
Technologies Inc., phone 1-800-927-6841 or 1-888-427-3973.  
Note: An arrow () found in the text signifies change in content.  
CAUTION  
Sharp Edges  
Wear protective gloves and safety  
glasses during installation.  
Description  
Termination Cap  
Storm Collar  
Qty  
1
1
Fastener Package  
1
32 in.  
(813 mm)  
32-3/8 in.  
(822 mm)  
34-1/4 in.  
(870 mm)  
15-3/4 in.  
(400 mm)  
34-3/8 in.  
(873 mm)  
TV342  
TR342  
TR344  
Note: The chimney must extend at least 3 ft (.91 m) above the highest point where it passes through the roof and at least  
2 ft (.61 m) above any portion of the building within 10 ft (3.05 m). These minimum distances comply with national code  
construction requirements but do not guarantee smoke free operation.  
Hearth & Home Technologies Inc. • TR342/TR344 Term Cap • 31445 Rev H • 03/06  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  
B. TR342 and TV342 Telescoping Round Termination Cap  
The uppermost chimney section must terminate no more than 14-1/2 in. (368 mm) below the top of the flashing collar on  
the chase top. See Figure 3 for additional details.  
Position the telescoping round termination cap above the collar of the chase top and lower the cap assembly until the  
stainless steel telescoping slip section engages a minimum of 4 in. (102 mm) into the uppermost chimney section. Push  
the termination cap down until the three support brackets contact with the chase top collar.  
Attach the three support brackets to the chase top collar with the screws provided.  
Wrap the storm collar around the outer slip section.  
Fasten the ends of the storm collar together with a  
screw at the bottom and a nut and bolt through the  
Storm Collar  
2 in. (51 mm) min.  
clamp lock at the top. Slide the storm collar down  
until it contacts the chase top and tighten the clamp  
lock.  
Flashing Collar  
Caulk the gaps between the outer slip section  
and the top of the storm collar to prevent leaks.  
Any seams along the storm collar must also be  
sealed.  
14-1/2 in.  
(368 mm) max.  
Note: To protect against the effect of corrosion  
on those parts exposed to the weather, the  
termination cap can be painted with a rust-  
resistant paint.  
Top of Pipe  
1-1/2 in. (38 mm) min.  
overlap  
Figure 3  
I
nstalling TR342, TV342 Round Telescoping Termination Cap  
(TR342 shown)  
C. Shrouds  
Field Constructed Shrouds  
-
Different shroud designs have been tested for Hearth Technologies fireplace systems using the TR342 and TR344  
termination caps. These shrouds may be field constructed if the dimensional requirements specified in Table 1 are  
maintained. Some examples are shown in Figure 4. These shrouds must be constructed from a minimum .018 in.  
(26 ga) thick aluminized steel. The wire mesh is optional but recommended and must be .018 in. thick minimum  
aluminized steel with a maximum 1/2 in. (13 mm) mesh opening.  
-
The TR-TVK Round Termination Top Vent Kit is available to reduce the minimum sizes required for shrouds. See  
Table 1.  
17-1/2 in.  
(444 mm)  
Dia. centered  
3/4 in.  
(19 mm)  
17-1/2 in.  
(444 mm)  
Dia. centered  
*
3-3/4 in.  
(95 mm)  
17-1/4 in.  
(438 mm)  
28-1/4 in.  
(718 mm)  
*
3 in. (76 mm)  
(4 sides)  
*
3 in.  
(76 mm)  
*
*
2 in.  
(51 mm)  
* See Table 1 for measurements  
Figure 4  
Shroud Dimensions  
Installation of the Shroud  
Center the hole in the bottom pan (if required) of the shroud over the termination cap and lower the shroud down to  
the chase top.  
Be sure to keep the shroud centered over the chimney termination and fasten the shroud to the chase top with  
screws.  
Be sure to caulk or seal around the screw heads to prevent leaks.  
Hearth & Home Technologies Inc. • TR342/TR344 Term Cap • 31445 Rev H • 03/06  
3
Download from Www.Somanuals.com. All Manuals Search And Download.  
TABLE 1  
TV342  
TR342/TR344*  
TV11/TV11T  
TR11/TR11T*  
(* with TR-TVK installed)  
TS345/T445  
(Top Vent)  
TR342/TR344  
TR442/TR444  
TR442/TR444*  
(* with TR-TVK installed)  
Shroud  
TR11/TR11T  
OPEN TOP with solid sides and 3 in. (76 mm) opening at the bottom  
28 x 28 in.  
32 x 32 in.  
Mnimum Base  
Dimensions  
23 in. x 23 in.  
(584 x 584 mm)  
26 x 26 in.  
(660 x 660 mm)  
26 x 26 in.  
(660 x 660 mm)  
(711 x 711 mm)  
(813 x 813 mm)  
with Radiation Shield  
with Radiation Shield  
Minimum Top  
Dimensions  
20 x 20 in.  
(508 x 508 mm)  
25 x 25 in.  
(635 x 635 mm)  
23 x 23 in.  
(584 x 584 mm)  
29 x 29 in.  
(737 x 737 mm)  
23 x 23 in.  
(584 x 584 mm)  
MAILBOX STYLE with open ends and 3 in. (76 mm) opening at the bottom of the sides.  
28 x 30 in.  
26.5 x 28 in.  
(673 x 711 mm)  
with Radiation Shield  
34 x 34 in.  
(711 x 762 mm)  
with Radiation Shield or  
34 x 34 in.  
Minimum Base  
Dimensions  
28 x 30 in.  
(711 x 762 mm)  
N/A  
N/A  
(864 x 864 mm)  
with Radiation Shield  
(864 x 864 mm)  
28 1/4 in.  
(718 mm)  
27 1/2 in.  
(699 mm)  
28 1/4 in.  
(718 mm)  
27 1/2 in.  
(699 mm)  
Minimum Height  
ROOFED STYLE with 12 x 22 in. (264 sq. in.) (305 x 559 mm) opening on each side and 3 in. (76 mm) space between the  
radiation shield and chase top.  
27 x 27 in.  
27 x 27 in.  
34 x 34 in.  
34 x 34 in.  
Minimum Base  
Dimensions  
N/A  
N/A  
(686 x 686 mm)  
(686 x 686 mm)  
(864 x 864 mm)  
(864 x 864 mm)  
with Radiation Shield  
with Radiation Shield  
with Radiation Shield  
with Radiation Shield  
23 in.  
(584 mm)  
23 in.  
(584 mm)  
23 in.  
(584 mm)  
23 in.  
(584 mm)  
Minimum Height  
Minimum Height is measured from the bottom of the termination cap:  
Minimum height is established with the bottom of the termination cap 7 in. (178 mm) above the chase top. Minimum height must increase  
accordingly for any height above 7 in. (178 mm).  
All dimensions are INSIDE dimensions.  
4
Hearth & Home Technologies Inc. • TR342/TR344 Term Cap • 31445 Rev H • 03/06  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Blood Pressure Monitor 3A1331C User Manual
Haier Air Conditioner HWF05XC5 User Manual
Haier Washer HWM90 287S User Manual
Hamilton Beach Toaster 22811 User Manual
Harbor Freight Tools Tool Storage 47418 User Manual
Hotpoint Freezer HUT161I User Manual
HTC Cell Phone ONESTMB User Manual
Huawei Cell Phone M865 User Manual
Husqvarna Tiller 650RTTA User Manual
Icom Fish Finder EX 2714 User Manual