Hearth and Home Technologies Ventilation Hood ST1175 User Manual |
Installation
Instructions
��
Models:
ST1175
Termination Cap
These chimney termination caps have been tested for use with specific Hearth & Home Technologies Inc. (HHT) fireplaces
and is a fireplace part. Refer to the fireplace installation isntructions for the correct accessories to be used. Check with
your local building code agency before you begin installation to ensure compliance with local codes, including the need
for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarification
of any of the instructions contained here, contact the Heatilator Technical Services Dept., Hearth & Home Technologies
Inc., 1-800-927-6841 or 1-888-427-3973.
Item
1a
1b
2
Description
Termination Cap - Top
Termination Cap - Base
Slip Section
Qty
1
1
1
1
1a
1b
3
Fastener Package
3
FEET
Note: The ST1175 is designed for use
with the SL1100 Series pipe.
CHASE TOP
MAX. 4-3/4 in.
(121 mm)
CAUTION
2
Sharp Edges
•
Wear protective gloves and safety
glasses during installation.
Note: An arrow () found in the text signifies change in
content.
1. Assemble the SL1100 Series chimney Sections to within 4-3/4 in.
(121 mm) below the top of the chase.
2. Remove the top by taking out the four screws that secure it to the
corner posts. If the top is not screwed on, proceed to Step 3.
WARNING
3. Center the partially disassembled base of the termination cap
over the chimney (inside the chase). Drop the double walled slip
section through the flanged opening in the base of the termina-
tion cap so it telescopes both the inner and the outer chimney
sections.
Fire Risk
•
Intended for use with a metal chase
top.
Use of combustible materials will cause a
fire hazard.
4. Adjust the termination cap so the slip section does not bind the
chimney section. Rotate the cap so it is square with the chase
and mark the position using the holes provided in the feet as a
guide.
5. Drill through the chase top using a 1/8 in. (3 mm) diameter drill
bit at the marked locations. Securely attach the cap to the chase
using the screws provided in the fastener package.
WARNING
Fire Risk
You must use the slip section provided with
this chimney top.
6. Assemble the top of the termination cap and replace and tighten
all the screws.
•
Single wall or other variations from the
slip section MUST NOT be used.
7. Caulk all screws or nails on the chase top. Periodic re-caulking
may be needed to prevent leaks from developing.
Substitute parts may increase temperatures
to adjacent combustible materials.
Hearth & Home Technologies Inc. • ST1175 Termination Cap • 34502 Rev E • 01/05