Hearth and Home Technologies Ventilation Hood ST1175 User Manual

Installation  
Instructions  
 
Models:  
ST1175  
Termination Cap  
These chimney termination caps have been tested for use with specific Hearth & Home Technologies Inc. (HHT) fireplaces  
and is a fireplace part. Refer to the fireplace installation isntructions for the correct accessories to be used. Check with  
your local building code agency before you begin installation to ensure compliance with local codes, including the need  
for permits and follow-up inspections. If you encounter any problems regarding code approvals, or if you need clarification  
of any of the instructions contained here, contact the Heatilator Technical Services Dept., Hearth & Home Technologies  
Inc., 1-800-927-6841 or 1-888-427-3973.  
Item  
1a  
1b  
2
Description  
Termination Cap - Top  
Termination Cap - Base  
Slip Section  
Qty  
1
1
1
1
1a  
1b  
3
Fastener Package  
3
FEET  
Note: The ST1175 is designed for use  
with the SL1100 Series pipe.  
CHASE TOP  
MAX. 4-3/4 in.  
(121 mm)  
CAUTION  
2
Sharp Edges  
Wear protective gloves and safety  
glasses during installation.  
Note: An arrow () found in the text signifies change in  
content.  
1. Assemble the SL1100 Series chimney Sections to within 4-3/4 in.  
(121 mm) below the top of the chase.  
2. Remove the top by taking out the four screws that secure it to the  
corner posts. If the top is not screwed on, proceed to Step 3.  
WARNING  
3. Center the partially disassembled base of the termination cap  
over the chimney (inside the chase). Drop the double walled slip  
section through the flanged opening in the base of the termina-  
tion cap so it telescopes both the inner and the outer chimney  
sections.  
Fire Risk  
Intended for use with a metal chase  
top.  
Use of combustible materials will cause a  
fire hazard.  
4. Adjust the termination cap so the slip section does not bind the  
chimney section. Rotate the cap so it is square with the chase  
and mark the position using the holes provided in the feet as a  
guide.  
5. Drill through the chase top using a 1/8 in. (3 mm) diameter drill  
bit at the marked locations. Securely attach the cap to the chase  
using the screws provided in the fastener package.  
WARNING  
Fire Risk  
You must use the slip section provided with  
this chimney top.  
6. Assemble the top of the termination cap and replace and tighten  
all the screws.  
Single wall or other variations from the  
slip section MUST NOT be used.  
7. Caulk all screws or nails on the chase top. Periodic re-caulking  
may be needed to prevent leaks from developing.  
Substitute parts may increase temperatures  
to adjacent combustible materials.  
Hearth & Home Technologies Inc. • ST1175 Termination Cap • 34502 Rev E • 01/05  
1
Download from Www.Somanuals.com. All Manuals Search And Download.  

Greenheck Fan Ventilation Hood 462102 User Manual
Grizzly Saw G8976 User Manual
Grundig CRT Television T55 830 text User Manual
Hatco Food Warmer FR2 Series User Manual
Honeywell Smoke Alarm IPGSM DPC User Manual
Hotpoint Double Oven UY46 User Manual
HP Hewlett Packard All in One Printer PSC 2310 User Manual
HP Hewlett Packard Switch 2600 Series User Manual
Husqvarna Brush Cutter 327LDX series User Manual
Husqvarna Chainsaw 225LD User Manual