Hearth and Home Technologies Stove CB1200 B User Manual

R
CLASSIC BAY 1200 PELLET STOVE  
Owner’s Manual  
Portland  
Tested and  
Listed by  
O-T L  
Oregon USA  
Installation and Operation  
C
US  
OMNI-Test Laboratories, Inc.  
Model:  
CB1200-B  
NOTICE  
DO NOT DISCARD THIS MANUAL  
Read, understand and  
follow these instruc-  
tions for safe installa-  
tion and operation.  
Leave this manual with  
party responsible for use  
and operation.  
• Important operating and  
maintenance instruc-  
tions included.  
WARNING  
WARNING  
HOT SURFACES!  
Please read this entire manual  
before installation and use of this  
pellet fuel-burning room heater.  
Failure to follow these instructions  
could result in property damage,  
bodily injury or even death.  
Glass and other surfaces are  
hot during operation AND  
cool down.  
Hot glass will cause burns.  
Do not touch glass until it is cooled  
Do not store or use gasoline or other flam-  
mable vapors and liquids in the vicinity of this  
or any other appliance.  
NEVER allow children to touch glass  
Keep children away  
CAREFULLY SUPERVISE children in same room as  
• Do not overfire - If any external part starts to  
glow, you are overfiring. Reduce feed rate.  
Overfiring will void your warranty.  
fireplace.  
Alert children and adults to hazards of high  
temperatures.  
High temperatures may ignite clothing or other  
• Comply with all minimum clearances to com-  
bustibles as specified. Failure to comply may  
cause house fire.  
flammable materials.  
Keep clothing, furniture, draperies and other flammable  
materials away.  
CAUTION  
CAUTION  
Tested and approved for wood pellets and shelled  
field corn fuel only. Burning of any other type of fuel  
voids your warranty.  
Check building codes prior to installation.  
Installation MUST comply with local, regional, state and national  
codes and regulations.  
Consult local building, fire officials or authorities having jurisdic-  
tion about restrictions, installation inspection, and permits.  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
TABLE OF CONTENTS  
Section 8: Operating Instructions  
Section 1: Listing and Code Approvals  
A. Appliance Certifications ......................4  
B. Mobile Home Approved ......................4  
C. Glass Specifications............................4  
D. Electrical Rating..................................4  
E. BTU & Efficiency Specifications..........4  
A. Fuel Size & Material............................22  
B. General Operation Information ...........22  
C. Before Your First Fire .........................23  
D. Starting Your First Fire........................23  
E. Fire Characteristics.............................23  
F. Feed Rate Adjustment .......................23  
G. Ignition Cycles ....................................24  
H. Frequently Asked Questions...............24  
Section 2: Getting Started  
A. Design, Installation & Location  
Considerations....................................5  
B. Fire Safety ..........................................5  
C. Tools & Supplies Needed...................6  
D. Inspect Appliance & Components.......6  
Section 9: Troubleshooting ............................25-27  
Section 10: Maintaining & Servicing Appliance  
A. Proper Shutdown Procedures.............28  
B. Quick Reference Maintenance Chart..28  
C. General Maintenance & Cleaning.......28-31  
D. High Ash Fuel Content Maintenance ..32  
E. Blower Replacement...........................32-33  
F. Baffle Removal....................................33  
G. Igniter Replacement............................33  
H. Glass Replacement.............................34  
Section 3: Dimensions & Clearances  
A. Appliance Dimensions ........................7  
B. Clearances to Combustibles...............8  
C. Hearth Requirements..........................9  
Section 4: Vent Information  
A. Chimney & Exhaust Connection.........10  
B. Venting Termination Requirements ....10  
C. Equivalent Feet of Pipe.......................11  
D. Pipe Selection Chart............................11  
Section 11: Reference Material  
A. Component Functions & Locations.....35-36  
B. Component Locations (Drawings) ......37  
C. Exploded Drawings.............................38-40  
D. Service Parts & Accessories...............41-43  
E. Service & Maintenance Log................44  
F. Homeowner’s Notes ...........................45  
G. Warranty Policy...................................46-47  
H. Contact Information.............................48  
Section 5: Venting Systems  
A. Alcove .................................................12  
B. Through the Wall.................................13  
C. Vertical................................................14  
D. Through the Wall & Vertical ................14  
E. Masonry ..............................................15  
F. Alternate Masonry...............................15  
Section 6: Mobile Home..................................16  
Section 7: Appliance Set-Up  
A. Outside Air Kit, Rear & Floor ..............17  
B. Top Vent Adapter ...............................18  
C. Rear Vent & Rear to Top Vent Adapter.18  
D. Brick Set .............................................19  
E. Brick Clip ............................................19  
F. Log Set Placement..............................20  
G. Grille Assembly...................................20  
H. Logo Installation..................................20  
I. Door Installation..................................21  
J. Thermostat Installation........................21  
Page 3  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Listing and Code Approvals  
1
A. Appliance Certification  
E. BTU & Efficiency Specifications  
Model  
CB1200 Pellet Stove  
OMNI Test Laboratories, Inc.  
061-S-21-4  
Solid Fuel Room Heater/Pellet Fuel  
BurningType  
Emissions Rating  
*BTU Output  
0. 9 grams/hr  
14,000 - 40,000 / hr  
.
Laboratory  
Report No.  
Type  
Heating Capacity  
up to 2,500 sq. ft. depending  
on climate zone  
Hopper Capacity  
Fuel  
Shipping Weight  
80 lbs  
Wood Pellets or Shelled Corn  
349 lbs  
Standard  
ASTM E1509-95, ULC S627-M93 and  
ULC/ORD-C1482-M1990 Room Heater  
Pellet Fuel Burning type and (UM) 84-  
HUD, Mobile Home Approved.  
*BTU output will vary, depending on the brand of fuel you  
use in your stove. Consult your Quadra-Fire dealer for  
best results.  
State Listing Colorado, Listed 09-13-05  
B. Mobile Home Approved  
NOTE: Hearth & Home Technologies, manufacturer of  
this appliance, reserves the right to alter its products,  
their specifications and/or price without notice.  
This appliance is approved for mobile home installations  
when not installed in a sleeping room and when an outside  
combustion air inlet is provided. The structural integrity of  
the mobile home floor, ceiling, and walls must be maintained.  
The appliance must be properly grounded to the frame of  
the mobile home and use only Listed pellet vent Class “L”  
or “PL” connector pipe. A Quadra-Fire Outside Air Kit must  
be installed in a mobile home installation.  
C. Glass Specifications  
This appliance is equipped with 5mm ceramic glass. Replace  
glass only with 5mm ceramic glass. Please contact your  
dealer for replacement glass.  
NOTE: This installation must conform with local codes. In  
the absence of local codes you must comply with the ASTM  
E1509, ULC S627-M93, ULC/ORD-C-1482-M1990, (UM)  
84-HUD  
D. Electrical Rating  
115 VAC, 60 Hz, Start 4.1 Amps, Run 1.1 Amps  
Page 4  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Getting Started  
2
A
. Design, Installation & Location  
Considerations  
B. Fire Safety  
Maintain the designated clearances to combustibles. Insu-  
lation must not touch the chimney. You must maintain the  
designated air space clearance around the chimney. This  
space around a chimney is necessary to allow natural heat  
removal from the area. Insulation in this space will cause  
a heat buildup, which may ignite wood framing. NOTE:  
Clearances may only be reduced by means approved  
by the regulatory authority having jurisdiction.  
1. Appliance Location  
Consideration must be given to safety, convenience, traffic  
flow, and the fact that the appliance will need a chimney and  
chimney connector. It is a good idea to plan your installation  
on paper, using exact measurements for clearances and floor  
protection, before actually beginning the installation.  
If you are not using an existing chimney, place the appliance  
in a location to maintain a clear passage for the installation  
of any listed and approved pellet venting system. This appli-  
ance may be vented vertically or horizontally.  
To provide reasonable fire safety, the following should be  
given serious consideration:  
1. Install at least one smoke detector on each floor of  
your home to ensure your safety. They should be  
located away from the heating appliance and close  
to the sleeping areas. Follow the smoke detector  
manufacturer’s placement and installation instructions,  
and be sure to maintain regularly.  
Maintain specified vent clearance to comubstible require-  
ments listed by the pellet manufactures venting instructions  
and all clearance to combustivles listed in this manual.  
Check with your local building code agency before you begin  
your installation. Be sure local building codes do not super-  
sede UL specifications and always obtain a building permit  
so that insurance protection benefits cannot be unexpectedly  
cancelled. If any assistance is required during installation,  
please contact your local dealer.  
2. A conveniently located Class A fire extinguisher  
to contend with small fires resulting from burning  
embers.  
3. A practiced evacuation plan, consisting of at least 2  
escape routes.  
We recommend that a qualified building inspector and your  
insurance company representative review your plans before  
and after installation.  
4. A plan to deal with a hopper fire as follows:  
In the event of a hopper fire:  
2. Thermostat Location  
a. Evacuate the house immediately.  
b. Notify the fire department  
The thermostat’s location will have some effect on the  
appliance’s operation. When the thermostat is located close  
to the appliance, it may require a slightly higher temperature  
setting to keep the rest of the house comfortable. If the  
thermostat location is in an adjacent room or on a different  
floor level, you will notice higher temperatures near the  
appliance.  
WARNING  
Fire Hazard.  
Do not operate appliance before reading  
and understanding operating instructions.  
Failure to operate appliance properly may  
cause a house fire.  
CAUTION  
Do NOT connect this unit to a chimney flue servicing  
another appliance.  
Do NOT connect to any air distribution duct or system.  
Page 5  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
C. Tools And Supplies Needed  
D. Inspect Appliance & Components and  
Pre-Use Check List  
Tools and building supplies normally required  
for installation, unless installing into an existing  
masonry fireplace:  
1.  
2.  
Place the appliance in a location near the  
final installation area and follow the proce-  
dures below:  
Open the appliance and remove all the parts  
and articles packed inside the Component  
Pack. Inspect all the parts and glass for ship-  
ping damage. Contact your dealer if any irregu-  
larities are noticed.  
Reciprocating Saw  
Channel Locks  
Hammer  
Safety Glasses  
Framing Square  
Electric Drill & Bits (1/4”)  
1/4” Self-Tapping Screws  
Phillips Screwdriver  
Tape Measure  
Plumb Line  
May also need:  
Vent Support Straps  
Venting Paint  
Level  
Framing Material  
Hi-temp Caulking Material  
Gloves  
3.  
All safety warnings have been read and fol-  
lowed.  
4.  
5.  
6.  
7.  
This Owner’s Manual has been read.  
Floor protection requirements have been met.  
Venting is properly installed.  
The proper clearances from the appliance and  
chimney to combustible materials have been  
met.  
The masonry chimney is inspected by a profes-  
sional and is clean, or the factory built metal  
chimney is installed according to the manufac-  
turer’s instructions and clearances.  
The chimney meets the required minimum  
height.  
WARNING  
Inspect appliance and components for  
damage. Damaged parts may impair safe  
operation.  
8.  
Do NOT install damaged components.  
Do NOT install incomplete components.  
Do NOT install substitute components.  
Report damaged parts to dealer.  
9.  
10.  
11.  
All labels have been removed from the glass  
door.  
Plated surfaces have been wiped clean, if  
applicable.  
Thermostat or remote has been installed.  
A power outlet is available nearby.  
WARNING  
Fire Risk.  
Hearth & Home Technologies disclaims any  
responsibility for, and the warranty will be  
voided by, the following actions:  
12.  
13.  
Installation and use of any damaged appliance.  
Modification of the appliance.  
Installation other than as instructed by Hearth & Home  
Technologies.  
Installation and/or use of any component part not approved  
by Hearth & Home Technologies.  
Operating appliance without fully assembling all  
components.  
Operating appliance without legs attached (if supplied with  
unit).  
Do NOT Overfire  
Or any such action that may cause a fire hazard.  
Page 6  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Dimensions and Clearances  
3
A. Appliance Dimensions  
4-5/8 in  
20- 7/16 in.  
(519mm)  
8-1/6 in.  
(205mm)  
(118mm)  
12-3/8 in  
(314mm)  
14-1/4 in  
(362mm)  
C
L
5.0 in  
(127mm)  
2-1/2 in  
(64mm)  
C
L
25-3/4 in.  
(654mm)  
27-5/8 in.  
(692mm)  
28-1/2 in. (724mm)  
Figure 7.2 - Top View with Top Vent Adapter  
Figure 7.1 - Top View  
28-1/2 in.  
(724mm)  
25-3/4 in.  
(629mm)  
31-5/8 in.  
(803mm)  
C
L
10-3/4 in.  
(273mm)  
8-1/16 in.  
(205mm)  
24-3/4 in.  
(629mm)  
26-1/2 in.  
(673mm)  
Figure 7.3 - Side View  
Figure 7.4 - Front View  
Page 7  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
B. Clearances to Combustibles (UL and ULC)  
Inches Millimeters  
Alcove Installation  
Minimum Alcove Height  
Minimum Alcove Width  
Maximum Alcove Depth  
Minimum Alcove Side Wall  
44  
40-1/2  
36  
1117  
1029  
915  
A
C
6
152  
Top of Unit to Combustibles 12-1/2  
318  
B
C
WARNING  
Fire Risk.  
Inches Millimeters  
Straight Back Against  
Wall  
Comply with all minimum clearances to  
combustibles as specified.  
Back Wall to Appliance  
2
6
51  
A
B
Failure to comply may cause house fire.  
Side Wall to Appliance  
152  
Inches Millimeters  
51  
Corner Installation  
Walls to Appliance  
2
C
NOTE:  
Illustrations reflect typical installations and are FOR  
DESIGN PURPOSES ONLY.  
Illustrations/diagrams are not drawn to scale.  
Actual installation may vary due to individual design  
preference.  
Installations with:  
3 to 3 inch Top Vent Adapter and  
3 to 6 inch Offset Adapter Kit  
D
G
F
E
G
Inches Millimeters  
Vertical Installation  
Back Wall to Flue Pipe  
3
6
76  
D
E
F
Side Wall to Top  
152  
191  
Back Wall to Appliance  
7.5  
Inches Millimeters  
51  
Corner Installation  
Walls to Appliance  
2
G
Page 8  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
C. Hearth Pad Requirements (UL and ULC)  
Use a non-combustible floor protector, extending beneath  
appliance and to the front, sides and rear as indicated.  
Measure front distance “M” from the surface of the glass  
door.  
L*  
K
K
M
Figure 9.1  
Inches Millimeters  
Hearth Pad Requirements  
Sides  
Back  
Front  
2
2
6
51  
51  
K
L*  
M
152  
*L Exception for Horizontal Installations:  
USA INSTALLATIONS: A non-combustible floor protec-  
tion is recommended extending beneath the flue pipe  
when installed with horizontal venting or under the top  
vent adapter with vertical installation.  
CANADA INSTALLATIONS:  
A
non-combustible floor  
protection extending beneath the flue pipe is required  
with horizontal venting or under the top vent adapter with  
vertical installation.  
Must extend 2 inches (51mm) beyond each  
side of pipe (shaded area)  
Figure 9.2  
Page 9  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Vent Information  
4
B. Venting Termination Requirements  
A. Chimney and Exhaust Connection  
1. Chimney & Connector: Use 3 or 4 inch (76-102mm)  
diameter type "L" or "PL" venting system. It can be  
vented vertically or horizontally.  
CAUTION  
Do not terminate vent in any enclosed or semi-enclosed  
area such as a carport, garage, attic, crawl space, under a  
sun deck or porch, narrow walkway or closely fenced area,  
or any location that can build up a concentration of fumes  
such as a stairwell, covered breezeway, etc.  
2. Mobile Home: Approved for all Listed pellet vent. If  
using the 3 inch (76mm) vertical top vent adapter Kit  
or the 3 to 6 inch (76-152mm) top vent offset adapter,  
use Listed double wall flue connector. A Quadra-Fire  
outside air kit must be used with manufactured home  
installations.  
1. Termination must exhaust above air inlet elevation. It is  
recommended that at least 60 inches (1524mm) of verti-  
cal pipe be installed when appliance is vented directly  
through a wall. This will create a natural draft, which  
will help prevent the possibility of smoke or odor venting  
into the home during a power outage. It will also keep  
exhaust from causing a nuisance or hazard by exposing  
people or shrubs to high temperatures. The safest and  
preferred venting method is to extend the vent vertically  
through the roof.  
3. Residential: The 3 inch (76mm) vertical top vent  
adapter kit and the 3 to 6 inch (76-152mm) top vent  
offset adapter are tested to use 24 gauge single wall flue  
connector or Listed double wall flue connector to Class  
AListed metal chimneys, or masonry chimneys meeting  
national and/or local codes for solid fuel appliances.  
4. INSTALL VENT AT CLEARANCES SPECIFIED BY THE  
VENT MANUFACTURER.  
5. Secure exhaust venting system to the appliance with at  
least 3 screws. Also secure all connector pipe joints with  
at least 3 screws through each joint.  
2. Distance from doors and opening windows, or gravity or  
ventilation air inlets into building:  
a. Not less than 48 inches (1219mm) below;  
b. Not less than 48 inches (1219mm) horizontally  
from;  
NOTE: All pipe must be welded seam pipe whenever  
possible. Seal pipe joints with high temperature silicone  
(500°F [260°C] minimum rated only).  
c. Not less than 12 inches (305mm) above.  
3. Distance from permanently closed windows:  
NOTE: If burning shelled field corn, you must use  
approved venting specifically designed for corn. Follow  
the instructions from the venting manufacturer.  
a. Not less than 12 inches (305mm) below, horizontally  
from or above.  
4. Distance between bottom of termination and grade  
should be 12 inches (305mm) minimum. This is con-  
ditional upon plants in the area, and nature of grade  
surface. The grade surface must be a non-combustible  
material (i.e., rock, dirt). The grade surface must not be  
lawn. Distance between bottom of termination and public  
walkway should be 84 inches (2134mm) minimum.  
WARNING  
Fire Hazard.  
Only LISTED venting components may be  
used.  
NO OTHER vent components may be used.  
5. Distance to combustible materials must be 24 inches  
(610mm) minimum. This includes adjacent buildings,  
fences, protruding parts of the structure, roof overhang,  
plants and shrubs, etc.  
Substitute or damaged vent components may  
impair safe operation.  
6. Termination Cap Location (Home Electrical Service)  
Side-to-side clearance is to be the same as minimum  
clearance to vinyl inside corners.  
WARNING  
Vent surfaces get HOT, can cause burns if  
touched. Noncombustible shielding or guards  
may be required.  
Clearance of a termination cap below electrical service  
shall be the same as minimum clearance to vinyl soffits.  
Clearance of a termination cap above electrical service  
will be 12 inches (305mm) minimum.  
Location of the vent termination must not obstruct or  
interfere with access to the electrical service.  
Page 10  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
WARNING  
C. Equivalent Feet of Pipe  
Improper installation, adjustment, alteration, service or  
maintenance can cause injury or property damage. Refer  
to the owner’s information manual provided with this appli-  
ance. For assistance or additional information consult a  
qualified installer, service agency or your dealer.  
The table below can help you calculate the equivalent feet  
of pipe which is a method used to determine pellet vent size.  
Figure 11.1.  
Example of 3 Elbow-Rear Vent Termination Calculaton  
2 ft.  
Pellet Venting  
Component  
# of  
Feet of Multipled  
Equivalent  
Feet  
Components  
Equivalent Feet  
Elbows  
Pipe  
By  
X
o
90 Elbow or Tee  
3
5
3
15  
3 ft.  
o
45 Elbow  
X
Horizontal Pipe  
Vertical Pipe  
7
2
X
X
1
0.5  
7
1
2 ft.  
Total Equivalent Feet  
23  
Note: This is a generic example and is not  
intended to represent any specific fuel type.  
2 ft.  
Figure 11.1  
D. Pipe Selection Chart  
30  
20  
4 in. (102mm) Diameter Pipe Only  
The chart will help you in determining proper  
venting size according to the equivalent feet of  
pipe calculated above and the altitude above sea  
level of this installation. Figure 11.2.  
Example 1  
Equivalent Pipe  
Length In Feet  
Locate the calculated equivalent feet of pipe on  
the vertical left side of the chart. Move to the  
right horizontally on the chart until you reach  
your altitude above sea level.  
Example 2  
10  
If you fall below the diagonal line, 3 or 4 inch (76  
to 102mm) pipe may be used. If it is anywhere  
above the diagonal line, a 4 inch (102mm) diam-  
eter pipe is required.  
3 in. or 4 in. (76mm or 102mm) Diameter Pipe  
0
1
2
3
4
5
6
7
8
9
10  
ALTITUDE IN THOUSANDS OF FEET  
The chart reveals that a 90° elbow is 5 times as  
restrictive to the flow of exhaust gases under  
positive pressure as 1 foot of horizontal pipe, and  
a foot of horizontal pipe is twice as restrictive as  
a foot of vertical pipe.  
Figure 11.2  
Example 1: If the equivalent length of pipe is 23  
feet with altitude of 8,000 feet you must use 4 inch  
(102mm) diameter type “L” or “PL” vent.  
Example 2: If the equivalent length of pipe is 12 feet  
with altitude of 6,000 feet you may use 3 or 4 inch (76  
to 102mm) diameter type “L” or “PL” vent  
WARNING  
Fire Risk.  
Do NOT pack insulation or other  
combustibles between firestops.  
ALWAYS maintain specified clearances  
around venting and firestop systems.  
Install firestops as specified.  
Failure to keep insulation or other material  
away from vent pipe may cause fire.  
Page 11  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Venting Systems  
5
A. Alcove  
A
C
D
B
Figure 12.1  
Inches Millimeters  
Alcove Installation  
Minimum Alcove Height  
Minimum Alcove Width  
Maximum Alcove Depth  
Minimum Alcove Side Wall  
44  
40-1/2  
36  
1117  
1029  
915  
A
B
C
D
6
152  
not shown Top of Unit to Combustibles 12-1/2  
318  
All minimums listed are to a combustible surface.  
NOTE:  
Illustrations reflect typical installations and are FOR  
DESIGN PURPOSES ONLY.  
Illustrations/diagrams are not drawn to scale.  
Actual installation may vary due to individual design  
preference.  
Page 12  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
B. Through The Wall  
NOTE:  
Horizontal termination cap must be a minimum of 12 inches.  
(305mm) from the wall. Approved for mobile home instal-  
lations. Must use 3 or 4 inch (76-102mm) “L” or “PL” listed  
pellet venting or listed double wall pipe and a Quadra-Fire  
outside air kit in mobile homes.  
In Canada, where passage through a wall or partition of  
combustible construction is desired, the installation shall  
conform to CAN/CSA-B365  
2 in.  
Straight Out  
(51mm)  
Minimum  
6 in.  
(152mm)  
Minimum  
From Glass  
Horizontal  
Termination  
Cap  
Wall  
Thimble  
12 in.  
(305mm)  
Minimum  
Non-combustible Hearth Pad  
Figure 13.1  
45 Degree  
Illustration shows venting going in both directions.  
Choose which one is best for your installation.  
12 in. (305mm)  
Minimum  
Wall  
Thimble  
2 in. (51mm)  
Minimum  
12 in.  
(305mm)  
Minimum  
2 in. (51mm)  
Minimum  
Figure 13.2  
Page 13  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
C. Vertical  
We recommend a minimum of 60 in.  
(1524mm) vertical, however above the eave  
is preferred.  
Rain Cap  
Both installations are approved for mobile  
home installations. Must use 3 or 4 inch (76  
to 102mm) “L” or “PL” Listed pellet venting or  
listed double wall pipe and Quadra-Fire out-  
side air kit in mobile homes. Single wall pipe  
is approved for residential installations only.  
Flashing  
Firestop  
24 in. (610mm)  
minimum  
Class A Chimney  
Connector Adapter  
Ceiling Support  
3 in. (76mm)  
Min.  
6 in.  
(152mm)  
Min.  
Top Vent Kit  
Clean-out  
Cover  
Non-combustible Hearth Pad  
Figure 14.1  
Rain Cap  
D. Through The Wall & Vertical  
24 in. (610mm)  
Minimum  
Flashing  
2 in. (51mm) Minimum  
Support Bracket  
every 60 in. (1524mm)  
6 in. (152mm)  
Minimum  
Wall Thimble  
Tee  
Clean-out Cover  
Non-Combustible Hearth Pad  
Figure 14.2  
7014-082D  
Page 14  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
WARNING  
Fire Hazard  
Inspection of Chimney:  
Masonry chimney must be in good condition.  
Meets minimum standard of NFPA 211  
Factory-built chimney must be 6 in. (152mm) UL103 HT.  
E. Masonry  
Fireclay Flue  
Liner with Airspace  
Concrete Cap  
Flashing  
1 in. (25mm) Clearance  
with Firestop  
1 in. (25mm) Clearance  
3 in. (76mm) Minimum  
6 in. (152mm)  
Minimum  
Sheathing  
Cleanout Cover  
Airtight  
Clean-out Door  
Non-Combustible Hearth Pad  
Figure 15.1  
F. Alternate Masonry  
Fireclay Flue Liner  
withAirspace  
Concrete Cap  
Flashing  
1 in. (25mm) Clearance  
with Firestop  
1 in. (25mm)  
Clearance  
2 in. (51mm) Minimum  
6 in. (152mm)  
Minimum  
Sheathing  
Airtight Clean-out Door  
Non-Combustible Hearth Pad  
Figure 15.2  
Page 15  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Mobile Home  
6
A. Mobile Home Installation  
You must use a Quadra-Fire Outside Air Kit  
for installation in a mobile home.  
CAUTION  
Maintain structural integrity of mobile home:  
Floor, wall, ceiling and/or roof.  
Do NOT cut through:  
1. An outside air inlet must be provided for the combustion  
air and must remain clear of leaves, debris, ice and/or  
snow. It must be unrestricted while the appliance is  
in use to prevent room air starvation which causes  
smoke spillage. Smoke spillage can also set off smoke  
alarms.  
Floor joist, wall, studs or ceiling trusses.  
Any supporting material that would affect the structural  
integrity.  
2. The combustion air duct system must be made of  
metal. It must permit zero clearance to combustible  
construction and prevent material from dropping into  
the inlet or into the area beneath the dwelling and  
contain a rodent screen.  
CAUTION  
Never draw outside combustion air from:  
Wall, floor or ceiling cavity  
Enclosed space such as an attic or garage  
3. The appliance must be secured to the mobile home  
structure by bolting it to the floor (using lag bolts).  
Use the same holes that secured the appliance to the  
shipping pallet.  
Spark Arrestor Cap  
Roof Flashing  
4. The appliance must be grounded with #8 solid copper  
grounding wire or equivalent, terminated at each end  
with an NEC approved grounding device.  
Storm Collar  
5. Refer to Clearances to Combustibles and floor pro-  
tection requirements on pages 8 & 9 for listings to  
combustibles and appropriate chimney systems.  
6. Use silicone to create an effective vapor barrier at  
the location where the chimney or other component  
penetrates to the the exterior of the structure.  
7. Follow the chimney manufacturer’s instructions when  
installing the vent system for use in a mobile home.  
Joist Shield/Firestop  
Approved Class “L” o  
“PL” Pellet Vent  
8. Installation shall be in accordance with the Manufactur-  
ers Home & Safety Standard (HUD) CFR 3280, Part  
24.  
WARNING  
Figure 16.1  
Installation must comply with Manufactured Home and  
Safety Standard (HUD), CFR 3280, Part 24.  
WARNING  
Never install in a sleeping room.  
Page 16  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Appliance Set-Up  
7
2. Floor Installation  
a. Remove rear screen and set aside.  
A. Outside Air Kit Instructions  
Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose  
clamps, 1 collar assembly, termination cap assembly, 1  
trim ring, 12 screws.  
Tools Needed: Phillips head screw driver; wire cutters;  
hole saw or jig saw.  
b. Install cover plate over hole in right rear floor.  
c. Cut a 2 inch minimum hole in the floor to accommodate  
flex hose.  
d. Attach hose to termination cap.  
1. Rear Installation  
e. Place rope under pedestal to close off air leaks.  
a. Measure distance from floor to air vent opening in appli-  
ance and mark location on wall.  
Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch  
(64-76mm) opening on inside wall and a 3 to 3-1/2 inch  
(76-89mm) opening on outside of house.  
Screen  
b. Use hose clamp to secure flex pipe to collar assembly.  
c. Slide trim ring over flex pipe and run pipe through wall.  
d. Attach hose to outside termination cap with second  
hose clamp.  
Install Cover Plate  
e. Secure termination cap to outside surface.  
f. Secure trim ring to interior wall.  
Seal Pedestal with 26 in. Rope  
g. Snip corners and remove plate. Figure 17.1.  
Figure 17.3  
h. Align and secure collar assembly with 2 of the 4 holes  
as shown. Figure 17.2.  
Termination  
Cap Assembly  
Hose Clamp  
Trim Ring  
Snip Corners  
and remove  
plate  
Figure 17.1  
Secure Collar  
Flex Hose  
Figure 17.2  
Hose Clamp  
CAUTION  
Never draw outside combustion air from:  
Collar Assembly  
Figure 17.4  
Wall, floor or ceiling cavity  
Enclosed space such as an attic or garage  
Page 17  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
C. Rear Vent and Rear Vent to Top Vent  
Adapter Installation  
B. Top Vent Adapter Installation  
3 to 3 inch Top Vent Adapter  
3 to 6 inch Top Vent Offset Adapter  
Installing the Top Vent Adapter  
1. Put a layer of high temperature silicone on the 3 inch  
(76mm) exhaust outlet.  
2. Slide the top vent adapter onto the rear exhaust outlet  
and adjust the assembly to a vertical position.  
3. Drill 4 holes with #26 drill bit (provided) into the back of  
the appliance using the outer shield as a pattern (make  
sure the assembly is vertical). Figure 18.1  
Clean-Out Cover  
4. Install the 4 mounting screws.  
Figure 18.2 - Rear Vent Adapter  
5. Install the vent pipe into the top vent adapter (be sure  
to silicone all joints).  
6
To clean the top vent adapter, open the clean-out cover.  
See Figure 18.1  
3" - 6"  
Drill holes in back of  
Offset  
Clean-Out Cover  
stove and secure with 4  
Adapter  
screws, 2 on each side.  
o
Figure 18.3 - Rear to Top Vent Adapter - 90  
Clean Out  
Cover  
3" - 3"  
Top Vent  
Adapter  
1. Put a layer of high temperature silicone on the 3 inch  
(76mm) exhaust outlet.  
2. Slide the adapter onto the rear exhaust outlet and adjust  
the assembly to the appropriate position.  
3. Install the vent pipe into the adapter (be sure to silicone  
all joints)  
Figure 18.1  
Page 18  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
E. Brick Clip Installation  
D. Optional Brick Set Installation  
1. Remove the baffle first, follow instructions on page 33.  
WARNING  
2. Slide bottom of left rear brick in first; rotate top edge  
toward rear of appliance and then rotate outer edge  
toward rear of appliance, until brick slides into place.  
Figure 19.1.  
Risk of Injury.  
Brick may have small wires protruding from  
the back of brick.  
3. Repeat with right rear brick.  
1. After the brick set has been installed, 2 brick clips need  
to be installed on the outer edge of each baffle to hold  
the brick set in place.  
4. Place left side brick along left side of firebox, making sure  
chamfered (beveled) back edge of brick fits snugly next  
to rear brick. Figure 19.2.  
2. Remove 2 baffles from the appliance. Slide the baffle up  
and the bottom edge should fall down and then lift the  
baffle out.  
5. Repeat with right side panel.  
6. Complete brick set, correctly installed. Figure 19.3.  
3. Using pliers, bend the brick clip slightly past 90° in the  
direction shown in Figure 19.4.  
4. Position the brick clip as shown in Figure 19.4 and use  
pliers to crimp around the outside edge of the baffle as  
shown in Figure 19.5.  
Note: Figure 19.5 shows the finished shape of the brick  
clip, after being bent around the outside edge of  
the baffle.  
1
5. Slide the baffle back into place making sure that the brick  
clip holds the side brick toward the wall of the firebox.  
Push back on the sides so they will keep the rear bricks  
in place. Repeat for opposite side.  
Figure 19.1  
Approximately  
1 inch from corner  
1
3
2
Outside edge  
of Baffle  
Top outside  
corner of Baffle  
Use pliers to crimp  
Brick Clip around edge  
Figure 19.2  
Figure 19.4  
4
3
2
1
Installed Clip  
Figure 19.5  
Figure 19.3  
Page 19  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
F. Optional Log Set Placement Instructions  
G. Optional Gold or Nickel Grille Assembly  
CAUTION  
CAUTION  
Logs are FRAGILE. Use extreme care when handling or  
Do not open top all the way back so the weight of the  
top is supported by the hinges. It will damage the  
hinges. It will be necessary to prop the top up with  
a supporting brace. You can use the shipping box as  
shown in Figure 1.  
cleaning logs.  
1. Place the front log in first as shown in Figure 20.1. Place  
log between firepot and face of appliance with charred  
area surrounding firepot.  
1. Remove grille from packaging.  
2. Lift top up and place shipping box in vertically.  
3. Place 1 flap of the box lid into opening for stability.  
2. Set the left and right logs onto the front log, placing  
the holes in the base of the left and right logs over the  
locating pins in front log. See Figure 20.2. Ensure that  
the charred ends are facing the firepot.  
4. Align the 3 holes in the stove with the holes in the grille.  
5. Use a Phillips screwdriver to secure in place.  
6. Remove shipping box and lower top.  
Align the 3 hoes in the stove  
with the holes in the grille and  
secure in place.  
Place 1 flap of  
box lid into  
opening for  
stability  
LOCATING PINS  
CAUTION: Do not open top all the way back so the weight is  
supported by the hinges. It will damage the hinges. Prop the  
top up with supporting brace or use shipping box as shown.  
Figure 20.1  
Figure 20.3  
Charred Areas in the Back  
H. Installing Logo (Nickel Only)  
1. Remove logo from packaging.  
2. The logo has 2 studs on the back.  
Top Log  
Right  
3. Install the logo on the lower left side of the center  
panel by pressing the 2 studs into the pre-drilled  
holes. See Figure 20.4.  
Top Log, Left  
Front Log  
Figure 20.2  
NOTE:  
Due to the abrasive nature of a pellet appliance fire, the  
logs are not covered under warranty. Any placement varia-  
tion other than shown here can cause excessive heat and  
shall void the appliance warranty.  
Install Logo  
Figure 20.4  
Page 20  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
J. Thermostat Installation  
I. Door Installation  
To install door:  
1. Carefully remove door from packaging.  
1. A 12 volt AC thermostat is required to operate this pellet  
appliance. You may use the included wall mount thermo-  
stat or purchase an optional programmable thermostat  
or remote control. It is equipped with an adjustable  
heat anticipator. The current rating is .05 amps. The  
anticipator needs to be adjusted to the lowest setting  
available.  
2. Line up hinges with hinge pins on appliance body  
, and slide  
door down until it sits securely on pins.  
Figure 21.1.  
3. If door is plated, be sure to clean all plated surfaces and  
glass with a glass cleaner to ensure all oils are removed  
before your first burn.  
2. When mounting a thermostat on a wall, be sure to follow  
your thermostat installation instructions carefully.  
4. Remove all labels from glass before burning appliance.  
NOTE: Thermostat must be mounted level for  
accurate readings. The thermostat should be  
mounted on an inside wall and not in direct line  
with the appliance convection air.  
NOTE: If the thermostat is located too close to the  
appliance, you may need to set the temperature  
setting slightly higher to maintain the desired  
temperature in your home.  
To adjust latches:  
1. Close door securely  
.
2. Place rod in slot on the bracket on the door and close  
latch.  
3. Latch must close tightly enough to ensure an airtight  
seal between the door and the body of the appliance.  
To  
increase tension on the latch, turn the rod clockwise a few  
turns, then attempt to close the latch, until it is snug. Do not  
overtighten; you should be able to close the latch with your  
3. There is a 4 screw terminal block located on the back  
lower left corner of the stove directly above the power  
cord inlet. The center 2 screws are for the thermostat  
wires.  
hand. Figure 21.2  
.
4. After adjusting the latch, place a Phillips head screw driver  
in the end of the rod, and tighten the nut with a wrench.  
This will maintain the correct tension on the rod and latch.  
Hinge P  
in  
Hinge  
Power Outlet  
Figure 21.1  
Rod and nut  
Terminal Block.  
Center 2 screws for  
Thermostat Wires  
Figure 21.3  
CAUTION  
hock hazard.  
Do NOT remove grounding prong from plug.  
Plug directly into properly grounded 3 prong  
receptacle.  
Route cord away from appliance.  
Do NOT route cord under or in front of appliance.  
Rod and nut  
Figure 21.2  
Page 21  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Operating Instructions  
8
A. Fuel Size And Material  
1. Wood Pellets  
B. General Operating Information  
1. Thermostat Calls For Heat  
The appliance is like most modern furnaces; when the  
thermostat calls for heat, your appliance will automatically  
light and deliver heat. When the room is up to temperature  
and the thermostat is satisfied, the red call light will go off  
and the appliance will shut down.  
Fuel pellets are made from sawdust or wood by-products. If the  
source material is hardwood, they can have a higher mineral  
content, creating more ash. Fuels containing bark will also have  
higher ash content. Minerals and other noncombustible materials  
such as sand will turn into a hard, glass-like substance called  
a clinker when heated to the extreme temperatures our firepot  
reaches. This is what forms clinkers in the bottom of the firepot.  
Trees from different areas will vary in mineral content. That is  
why some fuels produce more clinkers than others. Pellets are  
manufactured in either 1/4 inch or 5/16 inch (6-8mm) diameter and  
should be no more than 1-1/2 inches (38mm) in length. Pellet  
lengths may even vary by lot from the same manufacturer which  
is why the feed rate may need to be adjusted occasionally. If you  
burn pellets longer than 1-1/2 inches (38mm) you may have  
an inconsistent fuel feed rate and/or missed ignitions.  
2. Heat Output Controls  
This appliance is equipped with a heat output control  
switch that has three settings or burn rates; low, medium  
and high. The appliance will turn on and off as the  
thermostat demands. When the thermostat calls for heat,  
the appliance will start up on the high setting for the first 4  
minutes and 15 seconds, then automatically switch to the  
burn rate for which it is set. If the appliance is set at one  
of the lower settings, it will run quieter but take longer to  
heat up an area than if it were set at a higher burn rate.  
Regardless of the burn rate, when the area is warm enough  
to satisfy the thermostat, the appliance will shut off.  
Pellet fuel quality can greatly fluctuate. We recommend using  
premium grade fuel with ash content less than 1%. Even in some  
fuel labeled “premium” ash content can vary from bag to bag and  
possibly exceed 1%. High ash fuel, or lack of maintenance, can  
cause the firepot to fill up and thus create a potential for smoking,  
sooting and possible hopper fires.  
3. Fan Speed Switch  
This switch will adjust the speed of the room distribution air  
fan or convection blower on all three settings. This means  
you have six different blower speeds available as there is  
a high and low on each setting.  
Always burn dry fuel. Burning fuel with high moisture content takes  
heat from the fuel and tends to cool the appliance, robbing heat  
from your home. Damp pellet fuel can clog the feed system.  
Heat  
Output  
Fan  
Speed  
We recommend that you buy fuel in multi-ton lots whenever  
possible. Buying large quantities of fuel at once will greatly  
reduce the number of times the feed adjustments will need to be  
made. However, we do recommend trying various brands before  
purchasing multi-ton lots to ensure your satisfaction.  
HIGH  
MED  
LOW  
HIGH  
LOW  
Reset Button Call Light  
WARNING  
Fire Risk.  
High ash fuels, or lack of maintenance,  
can cause the firepot to fill with ash  
and clinker. If the firepot fills to the top,  
immediately shut down the unit and clean.  
Figure 22.1  
Failure to do so could result in smoking,  
sooting and possible hopper fires.  
WARNING  
Fire Hazard.  
2. Shelled Field Corn  
Keep combustible materials, gasoline  
and other flammable vapors and liquids  
clear of appliance.  
Extensive factory and field testing has demonstrated shelled  
field corn to be an efficient and very economical fuel. We  
recommend the use of a 50-50 blend of corn and wood pellets.  
The only change in operation is that the feed rate may require  
a slight adjustment. The BTU output of the appliance varies  
slightly compared to pellets, depending on the quality of the  
corn used. In cases where it is acceptable for the appliance to  
run full time, 100% corn will work after the fire has been started  
using wood pellets.  
Do NOT store flammable materials in the appliance’s  
vicinity.  
Do NOT use gasoline, lantern fuel, kerosene, charcoal  
lighter fluid or similar liquids to start or “freshen up” a  
fire in this heater.  
Keep all such liquids well away from the heater while  
it is in use.  
Combustible materials may ignite.  
Page 22  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
E. Fire Characteristics  
C. Before Your First Fire  
A properly adjusted fire with the heat output control switch set  
on “high” has a short active flame pattern that extends out of  
the firepot approximately 4 to 6 inches (102 to 152mm). If  
the fire has tall flames with black tails and seems somewhat  
lazy, the feed rate will need to be reduced. This is done by  
sliding the fuel adjustment control rod down, which will reduce  
the feed. If the fire is not 4 to 6 inches (102 to 152mm) tall,  
slide the fuel adjustment control rod up to increase the feed.  
Amedium and low setting will give a shorter flame. The flame  
will rise and fall somewhat. This is normal.  
1. First, make sure your appliance has been properly  
installed and that all safety requirements have been met.  
Pay particular attention to the fire protection, venting and  
thermostat installation instructions.  
2. Double check that the ash drawer and firebox are  
empty!  
3. Check the position of the thermocouple, located above  
the firepot, and make sure that it protrudes approximately  
3/4 inch (19mm) into the firepot.  
4. Close the front door.  
F. Feed Rate Adjustment Instructions  
NOTICE: The tip of the thermocouple must be in contact  
with the inside end of the thermocouple cover or missed  
ignitions can occur.  
The feed adjustment control rod is factory set, and should  
be adequate for most fuels. The set screw is located at the  
bottom of the hopper and set loose at the factory so the  
fuel adjustment control rod will slide up and down by only  
loosening the thumb screw at the top. See Figure 23.1. Do  
not re-tighten bottom set screw.  
D. Starting Your First Fire  
1. A thermostat is required for proper operation of this  
appliance, except for corn. At this time, fill the hopper  
with pellets, set the thermostat to its lowest setting. Plug  
the power cord into nearby outlet.  
However, if the flame height is too high or too low, you will  
need to adjust the feed rate. Wait until the appliance has been  
burning for 15 minutes before making your adjustments and  
2. The exhaust blower will stay on for approximately 10  
minutes even though the thermostat is not calling for  
heat. This is normal.  
allow 15 minutes for feed adjustment to take effect.  
1. Loosen the thumb screw. Figure 23.1.  
2. Adjust the fuel adjustment control rod towards the "+"  
symbol to increase the feed rate and flame height or  
towards the "-" symbol, to decrease the feed rate and  
flame height.  
3. Locate the heat output control switch mounted on the  
upper right corner of the right side panel. Switch it to  
the high setting by pushing the top of the switch in, then  
adjust the thermostat to its highest setting. The red call  
light located on the upper right corner of the right side  
panel will be on. This indicates the thermostat is calling  
for heat.  
3. Re-tighten the thumb screw.  
4. The fuel feed system and the igniter should now be on.  
5. For your first fire it will be necessary to press the reset  
button every two minutes until pellets start to drop into  
the firepot, then press button 1 more time. This will fill the  
feed system and allow the appliance to begin dropping  
pellets. The appliance will continue to run as long as the  
thermostat is calling for heat.  
Fuel Adjustment  
Rod  
6. Once the appliance has ignited, let the it burn for  
approximately 15 minutes, then set the thermostat to the  
desired room temperature. Adjust the heat output control  
switch to the desired setting.  
Thumb  
Screw  
Set Screw  
Figure 23.1  
Page 23  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
G. Ignition Cycles  
WARNING  
Fire Risk  
Do NOT operate appliance:  
1. During each ignition cycle, it is normal to see some  
smoke in the firebox. The smoke will stop once the  
fire starts.  
With appliance door open.  
Firepot floor open.  
2. The convection blower will automatically turn on after  
your appliance has reached the set temperature on  
the “high” setting. This blower transfers heat from your  
appliance into the room, and will continue to run after  
the thermostat has stopped calling for heat until the  
appliance has cooled down.  
Cleaning slide plates open.  
Do NOT store fuel:  
Closer than required clearances to com-  
bustibles to appliance  
Within space required for loading or ash  
removal.  
3. Occasionally the appliance may run out of fuel and shut  
itself down. When this happens, the red call light will  
be on. To restart it, fill the hopper and press the reset  
button. (See Figure 22.1, page 22). When you press  
the reset button the red call light will go out. Release  
the button and the light will come back on. You should  
see a fire shortly. If not, follow the instructions on page  
23, of “Starting Your First Fire”.  
Back side of Firepot  
CAUTION  
Odors and vapors released during initial operation.  
Curing of high temperature paint.  
Open windows for air circulation.  
Firepot floor left open  
Odors may be irritating to sensitive individuals.  
Figure 24.1 - DO NOT LEAVE FIREPOT FLOOR OPEN  
H. Frequently Asked Questions  
ISSUES  
SOLUTIONS  
1. Metallic noise.  
1. Noise is caused by metal expanding and contracting as  
it heats up and cools down, similar to the sound pro-  
duced by a furnace or heating duct. This noise does not  
affect the operation or longevity of your insert.  
2. Ash buildup on glass.  
3. Glass has turned dirty.  
2. This is normal. Clean the glass.  
3. Excessive build up of ash. The lower burn settings will  
produce more ash, the higher burn settings produce  
less. The more it burns on low the more frequent clean-  
ing of the glass is required.  
4. Fire has tall flames with black tails and is lazy.  
4. The feed rate needs to be reduced or the firepot needs  
cleaning. Heat exchanger of exhaust blower needs  
cleaning.  
5. Smokey start-up or puffs of smoke from the airwash. 5. Either the firepot is dirty or there is too much fuel at  
start-up and not enough air. Close down feed rate 1/4  
inch at a time until this no longer happens.  
6. Large flame at start-up.  
Page 24  
6. This is normal. Flame will settle down once the fire is  
established.  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
With proper installation, operation, and maintenance your appliance will provide years  
of trouble-free service. If you do experience a problem, this troubleshooting guide  
will assist a qualified service person in the diagnosis of a problem and the corrective  
action to be taken. This troubleshooting guide can only be used by a qualified service  
technician.  
Troubleshooting  
9
Possible Cause  
No current to outlet.  
Corrective Action  
Check circuit breaker at service panel.  
Replace fuse.  
Symptom  
Plug in appliance - No  
response.  
.7 amp fuse defective.  
#3 snap disc tripped or defective.  
Control box defective.  
Reset or replace snap disc.  
Replace control box.  
Call light on. No fire.  
No fuel in firepot.  
Out of fuel.  
Check hopper. Fill with fuel.  
Replace snap disc.  
#2 snap disc may be defective.  
Vacuum switch not closing, no vacuum.  
Check exhaust blower is plugged in and  
operating.  
Check vacuum switch is plugged in.  
Check vacuum hose is in good condition,  
clear and connected at both ends.  
Check thermocouple is in good condition  
and plugged in properly.  
Make sure venting system is clean.  
Make sure front door is closed.  
Replace control box.  
Control box defective.  
Call light on. No fire.  
Partially burned fuel in  
firepot.  
Firepot clean-out plate not closed.  
Check that firepot clean-out plate is fully  
closed.  
Firepot is dirty (missed ignition).  
Clean firepot. Make sure there is no clinker  
in the firepot.  
Clinkers may have to be broken up with  
firepot scraper tool or other means.  
Call light on. No fire.  
Unburned pellets in  
firepot.  
Firepot clean-out plate not closed.  
Firepot is dirty.  
Check that firepot clean-out plate is fully  
closed.  
Clean firepot. Make sure there is not a  
clinker in the firepot. Clinkers may have to  
be pushed out of firepot with firepot scraper  
tool or other means.  
Scrape with solid piece of wire.  
Ignition hole blocked.  
Igniter not working.  
Remove ash drawer to see if igniter is  
glowing red on start-up.  
Check igniter wires for good connection.  
Replace igniter using 1/4 inch male /female  
spade connectors.  
Replace control box.  
Control box defective.  
Slow or smoky start-up. Firepot clean-out plate not closed.  
Firepot is dirty.  
Check that firepot clean-out is fully closed.  
Clean firepot. Make sure there is not a  
clinker in the firepot. Clinkers may have to  
pushed out of firepot with firepot scraper  
tool or other means.  
Reduce feed rate using feed rate adjust-  
ment control rod located inside hopper.  
Excessive amount of fuel at start-up.  
Page 25  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Symptom  
Possible Cause  
Corrective Action  
Check for ash build up in unit, includ-  
ing behind rear panels, firebox, heat  
exchanger, exhaust blower and venting.  
Slow or smoky start-up Dirty exhaust and/or venting system.  
(Cont’d)  
Feed system fails to  
start.  
Out of fuel.  
Check hopper, fill with fuel.  
#2 snap disc may be defective.  
Replace snap disc. Firebox door must be  
closed securely.  
Vacuum switch not closing. No vacuum.  
Check exhaust blower is plugged in and  
operating.  
Check vacuum switch is plugged in.  
Check vacuum hose is in good condition,  
clear and connected at both ends.  
Check thermocouple is in good condition  
and plugged in properly.  
Make sure venting system is clean.  
NOTE: High winds blowing into the vent-  
ing system can pressurize the firebox  
causing loss of vacuum.  
Feed system jammed or blocked.  
Empty hopper of fuel. Use a wet/dry  
vacuum cleaner to remove remaining fuel,  
from hopper, including feed tube.  
Check feed chute for obstructions.  
Loosen 2 screws and jiggle feed assembly.  
Feed spring not turning with feed motor.  
Feed motor defective or not plugged in.  
Check that set screw is tight on feed  
spring shaft at end of feed motor.  
Check connections on feed motor, replace  
if defective.  
No call light. Unit  
does not begin start  
sequence.  
Thermostat not set to a high enough tempera-  
ture.  
Adjust thermostat above room tempera-  
ture.  
Snap Disc #3 tripped.  
No power.  
Reset snap disc.  
Connect to power.  
Replace fuse.  
Fuse blown.  
Connections at thermostat and/or appliance not Check connections at thermostat and  
making proper contact.  
appliance.  
Defective thermostat or thermostat wiring.  
Replace thermostat or wiring.  
NOTE: To test thermostat and wiring, use  
a jumper wire at the thermostat block on  
the unit to by-pass thermostat and wiring.  
Control box defective.  
Call light on.  
Replace control box.  
Turn thermostat off.  
If call light does not go out, disconnect  
thermostat wires from unit. If call light  
does go out, thermostat or wires are  
defective.  
Unit fails to shut off.  
Page 26  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Corrective Action  
Symptoms  
Possible Cause  
Convection blower fails to #1 snap disc defective.  
Replace snap disc.  
start.  
Blower not plugged in.  
Check that blower is plugged into wire har-  
ness.  
Blower is defective.  
Replace blower.  
Control box is defective.  
Replace control box.  
Exhaust blower fails to  
start or does not shut off.  
Blower not plugged in.  
Check that blower is plugged into wire har-  
ness.  
Blower is clogged with ash.  
Blower is defective.  
Clean exhaust system.  
Replace blower.  
Replace control box.  
Control box is defective.  
Large, lazy flame, orange Dirty appliance.  
color. Black ash on glass. Poor fuel quality, high ash content.  
Clean unit, including firepot, heat exchang-  
ers and venting system. Remove stainless  
steel baffle from firebox to clean ash from  
on top of baffle. Clean behind rear brick  
panels. Change fuel brand to premium.  
Firepot clean-out plate not completely  
closed.  
Check that firepot clean-out plate is fully  
closed.  
Reduce feed rate using feed rate adjustment  
control rod located inside hopper.  
Excessive amount of fuel.  
Nuisance shutdowns.  
Low flame.  
Increase feed by opening feed rate adjust-  
ment control rod located inside hopper.  
Sawdust buildup in hopper.  
Feed motor is reversing.  
Clean hopper, see page 30.  
Check for good connections between feed  
motor and wire harness.  
Defective thermocouple.  
Defective control box.  
Replace thermocouple.  
Replace control box.  
Firepot more than 1/2 full.  
See page 31 for detailed instructions for  
“High Ash Fuel Content Management”  
Appliance calls for heat.  
Call light illuminates.  
Exhaust blower starts.  
No feed or igniter.  
Thermocouple is defective or not properly  
plugged in.  
Check connections on thermocouple or  
replace if defective.  
A flashing yellow light on the control box  
indicates a problem with the thermocouple.  
Defective control box  
Replace control box.  
Page 27  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Maintaining & Servicing Your Appliance  
10  
C. General Maintenance  
1. Types of Fuel  
A. Proper Shutdown Procedure  
CAUTION  
Depending on the type of fuel you are burning will dictate  
how often you have to clean your firepot.  
hock and Smoke Hazard  
If the fuel you are burning has a high dirt or ash content  
or you are burning shelled field corn, it may be necessary  
to clean the firepot more than once a day.  
Turn down thermostat, let appliance completely  
cool and exhaust blower must be off. Now you  
can unplug appliance before servicing.  
Dirty fuel will cause clinkers to form in the firepot. Aclinker  
is formed when dirt, ash or a non-burnable substance is  
heated to 2000°F (1093°C) and becomes glass-like. See  
D” page 32 in this section for more details on fuels with  
high ash content.  
• Smoke spillage into room can occur if appliance  
is not cool before unplugging.  
• Risk of shock if appliance not unplugged before  
servicing appliance.  
Follow the detailed instructions found in this  
section for each step listed as referenced in the  
chart below.  
Clinker  
Figure 28.1 - Clinker  
B. Quick Reference Maintenance Chart  
Cleaning or Inspection  
Ash Pan  
Frequency  
Every 5 bags of fuel  
Daily Weekly Monthly Yearly  
OR  
X
Ash Removal from Firebox  
More frequently depending on OR  
the fuel type or ash build-up  
X
Beneath Heat Exchanger  
Blower, Combustion (Exhaust)  
Every 1 ton of fuel  
More frequently depending on OR  
the fuel type  
More frequently depending on OR  
the fuel type  
Prior to heating season  
OR  
X
X
X
X
Blower, Convection  
Door Latch Inspection  
Exhaust Path  
OR  
More frequently depending on OR  
ash build-up  
X
X
Firebox - Prepare for Non-Burn Season At end of heating season  
OR  
OR  
OR  
OR  
Firepot - Burning pellets  
Firepot - Burning Corn  
Glass  
Every 3 bags  
Every 1 bag  
When clear view of firepot  
becomes obscure  
X
X
X
Heat Exchanger & Drop Tube  
Hopper  
Every 1 ton of fuel  
Every 1 ton of fuel or when  
changing fuel types  
OR  
OR  
X
X
Top Vent Adapter  
Venting System  
More frequently depending on OR  
the fuel type or ash build-up  
More frequently depending on OR  
the fuel type  
X
X
Page 28  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
2. Cleaning Firepot with Cleaning Rod & Firepot  
Scraper  
4. Cleaning Ash Pan  
Frequency: Weekly or every 5 bags of fuel  
By: Homeowner  
Frequency: Daily or more often as needed  
By: Homeowner  
Locate the ash pan underneath the firepot and using a  
slight pull up and out remove the ash pan. Empty into  
a non-combustible container and re-install ash pan.  
See Disposal of Ashes.  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off. If you are  
just cleaning the firepot, there is no need to unplug the  
appliance.  
5. Disposal of Ashes  
b. Pull firepot cleaning rod OUT and IN a couple of times  
to help shake debris loose. If rod is hard to pull, it may  
be necessary to use your firepot clean-out tool to chip  
away material that has built up on the bottom plate of  
the firepot and to push out any clinkers. Larger clinkers  
may have to be removed from the top of the firepot.  
Corn clinkers can be especially difficult to break up.  
Frequency: As needed  
By: Homeowner  
Ashes should be placed in a metal container with a  
tight-fitting lid. The closed container of ashes should  
be placed on a non-combustible floor or on the ground,  
well away from all combustible materials, pending final  
disposal.  
c. The firepot floor plate must be fully closed when  
finished. See Figure 27.1 on page 27.  
If the ashes are disposed of by burial in soil or otherwise  
locally dispersed, they should be retained in the  
closed container until all cinders have been thoroughly  
cooled.  
WARNING  
Fire Risk.  
WARNING  
NEVER pull firepot cleaning rods or cleaning  
slide plates when appliance is operating. Hot  
pellets may fall into ashpan and may start a  
fire or have mis-starts due to lack of vacuum.  
Heat exchanger cleaning rods may be warm  
to the touch. For safety purposes wear  
gloves.  
3. Ash Removal from Firebox  
Do not pull heat exchanger cleaning rods  
while appliance is operating.  
Frequency: Weekly or more frequently depending on  
ash build-up.  
Push cleaning rods IN when done, DO NOT  
leave cleaning rods OUT. Injury can occur.  
By: Homeowner  
a. Allow the appliance to completely cool down. There  
must not be any hot ashes in the firebox during  
cleaning. Turn the thermostat on and then immediately  
off to start the exhaust blower on its cycle time. It will  
pull fly ash out the exhaust instead of into the room.  
6. Cleaning Heat Exchanger Chambers & Drop Tube  
Frequency: Weekly or every 1 ton of fuel  
By: Homeowner  
b. Frequent cleaning of the ash in the firebox will help  
slow down the build-up of ash in the exhaust blower  
and vent system.  
The amount of ash buildup in the firepot will be a good  
guide to determine how often you should clean the heat  
exchangers.  
c. Open door. Remove ash with an ash vacuum or whisk  
broom and small dust pan.  
a. Allow the appliance to completely cool down before  
pulling the cleaning rods. Turn the thermostat on and  
then immediately off to start the exhaust blower on its  
cycle time. It will pull fly ash out the exhaust instead  
of into the room.  
d. This ash is deposited in the same ash pan as the  
firepot debris. The ash pan should be emptied every  
time you clean the firebox. Remember to place the ash  
and debris into a metal or non-combustible container.  
See Disposal of Ashes.  
b. To access the cleaning rods lift the hopper lid. Both  
black bent handle pull rods are located close to the  
face of the appliance to the left and right side.  
WARNING  
c. To clean, pull the rods straight out until it stops,  
approximately 20 inches (508mm). Slide the rods  
OUT and IN a couple of times.  
Disposal of Ashes  
Ashes should be placed in metal container  
with tight fitting lid.  
Ashes should be retained in closed container  
until all cinders have thoroughly cooled.  
Page 29  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
7. Cleaning Beneath Heat Exchanger  
10. Door Latch Inspection  
Frequency: Monthly or after burning 1 ton of fuel  
By: Homeowner  
Frequency: Prior to heating season  
By: Homeowner  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off  
.
b. A more thorough cleaning is needed to remove the  
excess ash that is left behind from the use of the  
cleaning rods for the heat exchanger tubes.  
b.To adjust, open the latch and pivot the holding rod out.  
Loosen the jam nut on the rod.  
c. With a Phillips head screw driver, turn the rod clockwise  
to tighten. The latch handle should snap securely in  
place when adjusted properly.  
c. The ash will be resting on the back of the baffles. This  
will require removing the baffles. Please refer to page  
33 for instructions on removing the baffles.  
d. After adjusting the latch, be sure to tighten the jam nut  
on the rod to hold the adjustment.  
8. Cleaning Exhaust Path  
Frequency: Yearly or more frequently depending on  
ash build-up.  
11. Door Gasket Inspection  
By: Homeowner  
Frequency: Prior to heating season  
By: Homeowner  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off  
b. Open the hinged access door on the left of the appli-  
ance.  
b. To inspect the door rope (gasket), open the door and  
see that the door rope extends approximately 1/8 inch  
(3mm) to 3/16 inch (9.5mm) from the door rope chan-  
nel.  
c. Reach in and unlatch the trap door that is connected  
to the rear of exhaust blower.  
d. Use a small vacuum hose attachment to clean area.  
e. Re-latch and close trap door.  
c. It should show signs of compaction all the way around  
the door where the rope contacts the face of the appli-  
ance. Confirm there are no air leaks.  
NOTE: There are heavy duty vacuum cleaners specifically  
designed for solid fuel appliance cleaning.  
12. Cleaning the Hopper  
9. Cleaning the Glass  
Frequency: Monthly or after burning 1 ton of fuel  
By: Homeowner  
Frequency: When clear view of the firepot becomes  
obscure.  
After burning approximately 1 ton of fuel or changing  
fuels you will need to clean the hopper to prevent saw-  
dust build-up.  
By: Homeowner  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off.  
A combination of sawdust and pellets on the auger  
reduces the amount of fuel supply to the firepot. This  
can result in nuisance shutdowns and mis-starts.  
b. Use a damp paper towel or any nonabrasive glass  
cleaner. Wipe off with dry towel.  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off.  
CAUTION  
b
Empty the hopper of any remaining pellets.  
Handle glass assembly with care.  
c. Vacuum the hopper and feed tube.  
When cleaning glass:  
13. Cleaning Exhaust Blower - Requires No Lubrication  
Avoid striking, scratching or slamming  
glass.  
Frequency: Yearly or as needed  
By: Quality Service Technician/Homeowner  
Task:: Contact your local dealer.  
Do NOT clean glass when it is hot.  
Do NOT use abrasive cleaners.  
Use a hard water deposit glass cleaner on white film.  
Refer to maintenance instructions.  
14. Cleaning Convection Blower - Requires No  
Lubrication  
Frequency: Yearly or as needed  
By: Qualified Service Technician  
Task: Contact your local dealer.  
Page 30  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
17. Preparing Firebox for Non-Burn Season  
15. Soot and Fly Ash: Formation & Need for Removal  
in Exhaust Venting System.  
Frequency: Yearly  
By: Homeowner  
Frequency: Yearly or more frequently depending on  
ash build-up.  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off.  
By: Qualified Service Technician/Homeowner  
b. Remove all ash from the firebox and vacuum thoroughly.  
c. Paint all exposed steel, including cast-iron.  
Be sure the appliance is allowed to cool, has been unplugged  
and the exhaust blower is off.  
The products of combustion will contain small particles of fly  
ash. The fly ash will collect in the exhaust venting system  
and restrict the flow of the flue gases.  
Use the Touch-Up paint supplied with the appliance;  
or,  
Purchase paint from your local dealer.  
At start-up if there is incomplete combustion, or if there is a  
shutdown or incorrect operation of the appliance it will lead  
to some soot formation. This will collect in the exhaust vent-  
ing system.  
Must use a high-temperature paint made specifi-  
cially for heating appliances.  
The venting system may need to be cleaned at least once a  
year or more often depending upon the quality of your fuel  
or if there is a lot of horizontal pipe sections. Ash will build  
up more quickly in the horizontal sections.  
16. Cleaning the Top Vent Adapter  
Frequency: Yearly or more frequently depending on  
ash build-up.  
By: Homeowner  
a. The appliance must be in complete shutdown and  
the exhaust blower should be off. Allow the appli-  
ance to completely cool down.  
b. Open the clean-out cover. See Figure 31.1.  
c. Sweep out any ash build-up.  
NOTE: There are heavy duty vacuum cleaners specifi-  
ically designed for solid fuel appliance cleaning.  
Clean Out  
Cover  
Figure 31.1  
Page 31  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
E. Blower Replacement  
D. High Ash Fuel Content Maintenance  
Frequency: When the ash build-up exceeds more  
than half way up the firepot.  
By: Homeowner  
1. Convection Blower Replacement  
a. Use proper shut down procedures to shut down the  
appliance and let it completely cool.  
b. The convection blower is located at the bottom rear  
of the appliance. If an outside air kit is also installed,  
depending on your particular installation you may or  
may not have to remove the outside air flange. If you  
do, remove the 2 screws using a Phillips head screw-  
driver. You do not need to remove the flex pipe from  
the flange.  
Poor quality pellet fuel, or lack of maintenance, can create  
conditions that make the firepot fill quickly with ashes and  
clinkers.  
This condition makes the appliance susceptible to overfill-  
ing the firepot with pellets which may result in smoking,  
sooting and possible hopper fires. Figure 32.1 shows an  
example where the firepot overfills, pellets back up into the  
feed tube and ash has accumulated in the firebox.  
c. Remove the lower rear screen by removing the 4  
screws securing the screen to the unit.  
An inefficient and non-economical method of burning of  
fuel caused by poor quality pellet fuel is shown in Figure  
32.2.  
d. The motor is mounted on a removable bracket. Remove the  
2 screws just above the motor and the whole assembly will tilt  
down and pull out.  
The correct flame size when good quality, premium pellet  
fuel is burned is shown in Figure 32.3.  
e. Disconnect the wires from the blower. The wires coming  
from the wiring harness are white, red and tan and the  
wires coming from the blower are black, white and red.  
The white connects to white, the red to red and black to  
the tan color wire.  
If the ash buildup exceeds the half way point in the firepot  
IMMEDIATE ATTENTION AND CLEANING IS REQUIRED.  
Pellets Back Up  
Firepot Overfills  
In Feed Tube  
Ash Build Up in Firebox  
Figure 32.1  
Incorrect  
Outside Air  
Flex Hose  
Convection Blower  
Tall, Lazy Flame, Orange in Color  
Figure 32.2  
Figure 32.4  
Correct  
Correct Flame Size, Yellow/White in Color  
Figure 32.3  
Page 32  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
G. Igniter Replacement  
2. Exhaust Blower Replacement  
Remove existing blower:  
a. Use proper shut down procedures to shut down the appli-  
ance and let it completely cool and then unplug it.  
b. Use an 11/32" wrench or nut driver to loosen and remove  
the (6) nuts holding motor mount plate to the blower  
housing on your stove.  
c. Remove washer from beneath the terminal ring on the  
grounding wire.  
d. Pull motor/mounting plate from blower housing.  
Igniter Bracket  
e. Scrape off old gasketing material from blower housing.  
Igniter  
Thumb Screw  
Install new blower:  
Figure 33.1  
f. The blower and blower housing is shipped as a unit. It  
is necessary to separate them at this point if you are  
using the existing blower housing already installed on  
the appliance:  
1. Use proper shut down procedures to shut down the  
appliance and let it completely cool down and then  
unplug it and remove the ash drawer.  
2. Follow instructions to remove the ash drawer found on  
page 29. Remove the access plate directly above it  
by removing the 2 screws just below the ash catcher.  
g. Follow steps 2 and 3 above. Discard or set aside the new  
blower housing.  
h. Carefully remove gasketing from new housing and set  
onto the blower housing.  
3. The wire leads to the igniter are connected to the wire  
harness with 1/4 inch male / female spade connectors.  
These wires will pull forward approximately 4 to 5  
inches (102mm to 127mm). Disconnect the spade  
connections and remove the igniter from the chamber.  
Loosen the thumb screw and slide igniter out.  
Re-install blower to blower housing:  
i. Install blower on housing ensuring that wiring exits facing  
the 8 o’clock position. Place the washer and then the  
grounding wire on nearest mounting plate stud.  
4. Install new igniter into the chamber and tighten the  
thumb screw. Re-connect the wires to the 2 leads with  
the spade connectors.  
j. Use nuts removed in step b to secure blower to hous-  
ing.  
5. Remove right side panel and pull wire leads back  
toward the rear of the appliance to take-up the 4 to 5  
inches (102mm to 107mm) previously pulled out. This  
will keep the wires out of the way of the ash drawer.  
Double check that the igniter wires are clear of any  
movement, i.e. ash drawer, firepot cleaning rod, etc.  
k. Re-connect wiring (use jumper wire if necessary). Re-  
connect power supply.  
F. Baffle Removal  
1. Use proper shut down procedures to shut down the  
appliance and let it completely cool down.  
6. Re-install the ash drawer and side panel and re-connect  
the power.  
2. Open right side panel and then open the door.  
3. The 2 baffles are located at the top inside of firebox.  
4. Place your hand on the baffle and slide it up and the  
bottom edge will fall down and then you can lift the baffle  
out. Repeat for the other side.  
Page 33  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
H. Glass Replacement  
WARNING  
Door Latch  
Glass is 5mm thick high temperature heat-  
resistant ceramic glass.  
Top & Bottom Frame  
DO NOT REPLACE with any other material.  
Alternate material may shatter and cause  
injury.  
Center Posts  
Glass  
• Remove door from appliance and place face down  
on a protected surface to avoid scratching the door.  
Side  
Frame  
• Remove all door rope.  
1. Replacing Center Glass  
NOTE: DO NOT LET Air Wash Spacers fall down from  
top frame when removing and replacing center  
glass.  
Figure 34.1  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off.  
b. Using a nut driver remove the (5) bottom nuts and  
remove the bottom glass frame. Figure 34.2.  
Remove Door Latch First  
and then Side Frame  
c. Slightly bend up and out of the way the 2 center posts  
and slide the glass out the bottom.  
d. Slide new glass in, reposition the 2 center posts and  
re-install bottom glass frame.  
Door Frame  
e. Re-rope the door.  
shown with no  
Glass or Glass  
Frames  
2. Replacing Side Glass  
NOTE: When removing the side glass with the door  
latch, you must remove the door latch first  
before removing the side frame. Use a pow-  
ered Phillips head screw driver to remove the  
4 screws.  
Remove 5 nuts from Bottom Frame  
a. Be sure the appliance is allowed to cool, has been  
unplugged and the exhaust blower is off.  
Figure 34.2  
b. Remove side glass frame.  
c. Loosen the top and bottom frame and slightly bend  
up and out of the way.  
WARNING  
d. Slide glass out the side and slide new glass in.  
Handle glass with care.  
e. Re-install the side glass frame and tighten the top  
and bottom frames.  
Inspect the gasket to ensure it is  
undamaged.  
Do NOT strike, slam or scratch glass.  
Do NOT operate appliance with glass  
assembly removed.  
f. Re-install the door latch, if applicable, and re-rope  
the door.  
Do NOT operate with glass cracked, broken or scratched.  
Page 34  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Reference Materials  
11  
When describing the location of a component,  
it is always AS YOU FACE THE FRONT OF  
THE APPLIANCE.  
A. Component Function & Location  
1. Control Box  
a. The control box is located under a small cover in the  
right rear corner of the inside of the hopper.  
7. Heat Exchangers  
The heat exchangers transfer hot air from the exhaust system  
into convection air. Lift the stove top to access the heat  
exchangers. There are 2 clean out rods located under the  
heat exchangers.  
b. There is a light located inside of the control box. The  
internal light will turn green when the appliance has  
ο
°
reached a temperature of 200 F (93 C) in the firepot  
and will turn red when it reaches 600 F (315 C).  
o
°
8. Heat Output Switch  
c. There is also an internal blue light located in the upper  
left corner of the control box. When you plug in the  
appliance the blue light will automatically start blinking  
1 blink every 10 seconds for the first 60 seconds and  
then will stop.  
The heat output switch is located on the upper right side panel.  
The function of the heat ouput switch is to regulate the burn  
rates; low, medium, and high settings.  
9. Igniter  
The igniter is mounted on the base of the firepot. Combustion  
air travels over the red hot igniter creating super heated air  
that ignites the pellets.  
NOTE:  
Do NOT open the control box. This will void the  
warranty. If you need to plug in or remove the control  
box you must first unplug the appliance.  
10. Junction Box And Wiring Harness  
The junction box is located on the right side of the appliance,  
behind the interior shield. The junction box and wiring harness  
are replaced as one component.  
2. Convection Blower  
The convection blower is mounted at the bottom rear of the  
appliance. There are 2 impellers, one on each side of the  
motor. The convection blower pushes heated air through the  
heat exchange system into the room.  
11. Power Supply  
The power outlet is located on the back of the appliance,  
lower right corner. Check the wall receptacle for 120 volt,  
60 Hz (standard current). Make sure the outlet is grounded  
and has the correct polarity. A good surge protector is  
recommended.  
3. Combustion (Exhaust) Blower  
The combustion blower is mounted on the lower left side  
on rear of appliance. The blower is designed to pull the  
exhaust from the appliance and push it out through the  
venting system.  
12. Red Call Light  
The red call light is on the front of the junction box, next to the  
reset button. The function of the red call light is to indicate  
that the thermostat is calling for heat.  
4. Feed System  
The feed system is located in the hopper under the feed  
motor cover box on the left side of the appliance and can  
be removed as an entire assembly. The assembly includes  
the feed motor, mounting bracket, bearing and feed spring  
(auger). The hollow feed spring (auger) pulls pellets up the  
feed tube from the hopper area and drops them down the  
feed chute into the firepot.  
13. Reset Button  
The reset button is located on the right side of the apppliance  
next to the red call light. The function of the button is to  
momentarily open the thermostat circuit, which restarts the  
system.  
14. Thermocouple  
5. Firepot  
The thermocouple is located on top of the firepot inside  
the thermocouple cover (ceramic protection tube). The  
thermocouple sends a millivolt signal to the control box  
indicating the preset temperatures of the green and red lights  
have been obtained.  
The firepot is made of high quality ductile iron and has a  
cleaning pull-out rod. The floor of the firepot opens for  
cleaning when you pull out the rod. Be sure that the floor  
returns to a completely closed position or your appliance will  
not operate properly.  
15. Thermostat  
6. Fuse  
The appliance is designed to run on a 12 volt AC thermostat.  
The heat anticipator should be set on the lowest setting  
available.  
The fuse is located on the front of the junction box on the  
right side of the appliance. The fuse will blow should a short  
occur and shut off power to the appliance.  
Page 35  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
16. Snap Disc #1 (Convection Blower) 145°F  
box from inside the hopper. If the fire tries to burn back  
Snap disc #1 is located on the right side of the appliance on into the feed system or push exhaust up the feed tube, this  
the top of the heat exchanger box. There are 2 purple wires snap disc will shut the entire system off. This disc must be  
connected to it. This snap disc turns the convection blower manually reset.  
on and off as needed. Power is always present at snap disc  
19. Vacuum Switch  
#1.  
The vacuum switch is located on the left side of the appliance  
behind the inner shield. This switch turns the feed system on  
17. Snap Disc #2 (Thermostat Override) 200°F  
Snap disc #2 is also located on the right side of the appliance when vacuum is present in the firebox. The vacuum switch  
between snap disc #1 and convection blower. There are 2 is a safety device to shut off the feed motor if the exhaust  
yellow wires connected to it. This snap disc will turn off the or the heat exchanger system is dirty or plugged or if the  
feed system, which will turn off the appliance if an overfire firebox door is open.  
condition should occur or if the convection blower should fail  
20. Wiring Harness  
to operate.  
See Figure 36.1 below.  
18. Snap Disc #3 (Back Burn Protector) 250°F  
Snap disc #3 is mounted on the back of the auger tube in the  
right side of the appliance just below the feed motor and has  
a red reset button. To access it remove the feed motor cover  
Female  
Male  
Heat  
Output  
Switch  
Thermocouple  
Thermostat  
Block  
Feed  
Motor  
Vacuum  
Switch  
Capacitor  
Blower  
Speed  
Snap  
Disc #2  
Yellow  
Purple  
Red  
Orange  
White  
Blue  
Snap  
Disc #1  
Convection  
Blower  
Black  
Black  
Yellow  
Red  
Purple  
Gray  
Blue  
High Temp  
High Temp  
Exhaust  
Blower  
Call Light  
Reset  
Button  
Fuse  
Snap  
Disc #3  
Igniter  
Figure 36.1  
Page 36  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
B. Component Locations  
Cleaning Rods  
Heat  
Output  
Fan  
Speed  
HIGH  
HIGH  
LOW  
MED  
LOW  
Reset Button Call Light  
Heat Exchanger Tubes  
Figure 37.3  
Figure 37.1  
Power Outlet  
Outside Air  
Flex Hose  
Terminal Block.  
Center 2 screws for  
Thermostat Wires  
Convection Blower  
Figure 37.2  
Figure 37.4  
Page 37  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
C. Exploded Views  
Nbr  
1
Description  
Door Frame  
Part Number  
not sellable  
510-5400  
8
7
2
Glass Assembly, Center  
Glass Assembly, Sides  
Glass Frame Post  
3
510-5410  
6
4
not sellable  
not sellable  
410-4912  
5
Glass Frame Side  
5
4
6
Door Latch Bracket  
Glass Frame Spacer  
Glass Frame, Top & Bottom  
Hinge, Female  
9
7
not sellable  
not sellable  
450-2910  
3
8
9
2
1
Glass Size Center: 13-7/8” wide x 11” high  
Glass Size Sides: 5-1/8” wide x 11” high  
Figure 38.1 - Door, Face, Glass & Door Latch Assembly  
Nbr  
Description  
Part Number  
7000-223  
47  
13 Thumb Screw  
14 Thermocouple  
812-0210  
42 Firepot Pull Rod (Linkage)  
43 Firepot, EZ Clean  
44 Igniter Bracket  
812-3850  
SRV7000-226  
not sellable  
SRV7000-226  
812-1322  
14  
48  
43  
45 Igniter (Heating Element)  
47 Thermocouple Cover  
48 Thermocouple Holder  
812-3171  
44  
13  
42  
45  
Figure 38.2 - Firepot, Igniter & Thermocouple  
Page 38  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
36  
35  
37  
29  
34  
38  
30  
33  
28  
32  
27  
39  
31  
48  
26  
47  
42  
40  
43  
44  
45  
41  
46  
25  
23  
24  
Figure 38.1  
Nbr  
23 Door Assembly  
24 Ash Pan  
25 Panel Access, Front (Firepot)  
26 Latch, Draw  
27 Director, Air, Large  
Nbr  
36 Baffle, Left  
37 Curtain Mount, Side, Left  
38 Curtain, Side, Left  
39 Curtain, Pedestal, Left  
40 Blower, Combustion (Exhaust)  
41 Gasket, Exhaust Blower  
42 Firepot Pull Rod Assembly (Linkage)  
43 Firepot, EZ Clean  
44 Igniter Bracket (Thumb Screw), not sellable  
45 Igniter, (Heating Element)  
46 Exhaust Plenum Trap Door  
47 Thermocouple, Cover  
Description  
Description  
28 Director, Air, Small  
29 Grille, Louvers  
30 Knob, Heat Exchanger Rods  
31 Brick, Right Side, not sellable  
32 Brick, Right Rear, not sellable  
33 Brick, Left Rear, not sellable  
34 Brick, Left Side, not sellable  
35 Baffle, Right  
48 Thermocouple Holder  
Page 39  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
66  
68  
67  
69  
72  
71  
64  
65  
62  
63  
70  
61  
60  
73  
74  
77  
76  
75  
56  
59  
55  
54  
58  
53  
52  
51  
57  
Figure 39.1  
Nbr  
Description  
Nbr  
65 Control Box  
66 Cover, Control Box  
67 Feed Adjustment Plate with Rod  
68 Cover, Feed Motor  
69 Feed Motor & Spring Assembly  
70 Curtain, Air Deflector, Left  
71 Hopper Lid  
Description  
51 Exhaust Plenum Clean-Out Plate  
52 Snap Disc, #1, 145-40 degree  
53 Blower, Convection  
54 Convection Air Plenum, not sellable  
55 Snap Disc, #2, 200 degree  
56 Curtain Mount, Side, Right  
57 Exhaust Plenum Plate, not sellable  
58 Curtain, Pedestal, Right  
72 Hopper Lid Handle  
59 Curtain, Side, Right  
73 Top Only  
60 Panel Access, Lower Rear Screen  
61 Curtain, Air Deflector, Right  
62 Latch, Magnet for Side Air Deflector Curtain  
63 Panel Access, Upper Rear Screen  
64 Vacuum Switch  
74 Hopper Access Plate  
75 Heat Shield Extension, Top  
76 Snap Disc, #3, 250 degree  
77 Junction Box & Wire Harness  
Page 40  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
D. Service Parts and Accessories  
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on the Quadra-  
Fire web site at www.quadrafire.com. When ordering, supply serial and model numbers to ensure  
correct service parts.  
Item #  
24  
Parts (Alphabetical Order)  
Part No.  
812-4050  
Ash Pan  
36  
Baffle Assembly, Left  
Baffle Assembly, Right  
Baffle Center  
510-5350  
510-5360  
812-3440  
812-3370  
812-3381  
225-0120  
812-4030  
410-4912  
7001-045  
35  
53  
40  
Blower, Convection  
Blower, Exhaust  
Bolt, Firepot, 1-1/4” long  
Bracket, Door Hinge  
Bracket, Door Latch  
Collar Assembly, Outside Air Kit  
Component Pack (Includes firepot clean-out tool, touch-up paint, power cord & wiring harness  
to the thermostat and manual, owner’s manual, warranty card, consumer’s view card and  
“How-To-Operate” DVD)  
812-3630  
65  
66  
68  
37  
56  
70  
61  
Control Box  
SRV7000-205  
410-6321  
410-5311  
410-5251  
410-5261  
410-4992  
410-5105  
410-5391  
812-3840  
812-3800  
410-4912  
410-4871  
812-4100  
812-4170  
812-4421  
812-3690  
230-2150  
410-7172  
SRV7037-024  
812-3351  
414-0290  
812-3850  
812-3850  
812-0380  
834-1460  
842-2350  
240-0812  
510-0530  
510-5400  
510-5410  
Cover, Control Box  
Cover, Feed Motor  
Curtain Mount, Side, Left  
Curtain Mount, Side, Right  
Curtain, Air Deflector, Left  
Curtain, Air Deflector, Right  
39,58 Curtain, Pedestal, Sides (interchangeable)  
38  
59  
6
Curtain, Side, Left  
Curtain, Side Right  
Door Latch Bracket  
51  
46  
67  
Exhaust Plenum Clean-Out Plate  
Exhaust Plenum Trap Door  
Feed Adjustment Plate with Rod  
Feed Motor  
69  
Feed Motor & Spring Assembly  
Feed Motor Capacitor Jumper  
Feed Motor Mount  
Feed Spring Only  
43  
42  
Firepot, EZ Clean  
Firepot Floor (Slide Plate)  
Firepot Pull Rod Assembly (Linkage)  
Firepot Rod/Linkage  
Fuse .7 amp, Junction Box  
Gasket, Ash Pan, 10 ft  
Gasket, (Rope) Door, cut to size, 7-1/2 ft  
Gasket, Exhaust Blower  
Gasket, Firepot  
41  
2
3
Glass Assembly, Center  
Glass Assembly, Left or Right, 1 pc  
Page 41  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Item #  
Service Parts (Alphabetical Order)  
Part No.  
Grille, Bar, Bottom  
410-8330  
72  
75  
Handle, Hopper Lid  
200-0110  
812-3500  
410-5322  
450-2910  
450-2810  
410-4901  
812-3811  
SRV7000-154  
200-0831  
229-0640  
812-3821  
226-0090  
7001-045  
811-0570  
7001-044  
410-5413  
410-6220  
410-5161  
410-5413  
410-4352  
812-1180  
230-0060  
230-0900  
230-1290  
812-3910  
7001-044  
812-0210  
812-1322  
812-3171  
7000-223/24  
812-3940  
SRV410-4980  
7000-166  
SRV7000-447  
Heat Output Control Switch, (Rocker Switch), 3 position  
Heat Shield Extension, Top  
Hinge, Female, Door  
Hinge, Male, Door  
71  
45  
77  
Hopper Lid  
Igniter, Loop (Heating Element), 6 inches  
Junction Box & Wire Harness  
Knob, Firepot Pull Rod  
Latch, Draw  
62  
Latch, Magnet for Side Air Delfector Curtain  
Nut, Firepot, 1/4-20  
Outside Air Collar Assembly  
Outside Air Floor  
Outside Air Termination Cap  
Panel Access, Bottom Rear Screen  
Panel Access, Feed Motor  
Panel Access, Front (Firepot)  
Panel Access, Bottom Screen  
Panel Access, Top Rear Screen  
Power Cord  
60  
25  
63  
52  
55  
76  
Snap Disc, #1, 145-40 Degree  
Snap Disc, #2, 200 Degree  
Snap Disc, #3, 250 Degree  
Switch, Rocker (Fan Speed)  
Termination Cap Assembly, Outside Air  
Thermocouple  
16  
47  
48  
12  
Thermocouple Cover  
Thermocouple Holder with Set Screw  
Thumb Screw, Pkg of 24  
Top Assembly with Hopper Lid  
Top Only  
73  
64  
Vacuum Switch  
Wire Harness  
Page 42  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Accessories  
Part No.  
811-0601  
Brick, Set, 4 pc  
Log Set, 3 pc  
811-0592  
Door Assembly, Black  
Door Assembly, Gold  
Door Assembly, Nickel  
Grille Assembly, Black  
Grille Assembly, Gold  
Grille Assembly, Nickel  
Outside Air Kit, Floor  
Outside Air Kit, Rear  
DR-CB12-BK  
DR-CB12-GD  
DR-CB12-NL  
LVGRL-CB12-NL  
LVGRL-CB12-GD  
LVGRL-CB12-MBK  
811-0570  
811-0872  
Rear to Top Vent Adapter, 90o  
Thermostat, Mechanical  
811-0620  
811-0610  
Thermostat, Programmable  
Top Vent Adapter, 3 in x 3 in  
Top Vent Offset Adapter Collar, 3 in x 6 in  
811-0520  
811-0580  
812-3570  
Appliance  
Part No.  
Classic Bay 1200 Freestanding Pellet Stove  
CB1200-B  
Page 43  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
E. Service And Maintenance Log  
Date of Service  
Performed By  
Description of Service  
Page 44  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
F. Homeowner’s Notes  
Page 45  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
G. Warranty Policy  
Hearth & Home Technologies LIMITED WARRANTY  
Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood,  
pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or  
Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.  
Warranty Period  
Parts Labor  
HHT Manufactured Appliances and Venting  
EPA  
Components Covered  
Gas  
X
Wood  
X
Pellet  
X
Electric  
X
Venting  
X
Wood  
All Parts and Material Except  
as covered by Conditions,  
Exclusion, and Limitations  
listed  
1 Year  
X
Igniters, Electronic Compo-  
nents, and Glass  
Blowers  
X
X
X
X
2 years  
3 years  
X
X
X
Molded Refractory Panels  
X
X
Firepots  
5 years  
3 years  
3 years  
X
X
Castings & Baffles  
Firebox, HHT Chimney, Termi-  
nation & Heat Exchanger  
7 years  
X
X
X
X
10  
1 year  
1 year  
X
years  
Burners, Logs & Refractory  
Limited  
Lifetime  
X
X
Firebox & Heat Exchanger  
All Replacement Parts  
90 Days  
X
X
X
See Conditions, Exclusions, and limitations.  
CONDITIONS, EXCLUSIONS & LIMITATION OF LIABILITY  
9-01-08  
This warranty applies to the original owner and is transferable up to two years from date of purchase to the new  
homeowner, provided the purchase was made through an authorized dealer or distributor of HHT, and the appliance  
remains in its original place of installation.  
The maximum amount recoverable under this warranty is limited to the purchase price of the product.  
In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product.  
Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the  
home is not covered under this warranty.  
This limited warranty does not extend to or include surface finish on the appliance or terminations, door gasketing,  
glass gasketing, glass discoloration, firebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or  
corrosion on any of the metal surfaces, cast iron components, baffles, firepots, doors, or firebox area are not covered  
by this warranty.  
Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to  
4021-645A 09-01-08  
Page 46  
7014-082D  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CB 1200 Pellet Stove  
Hearth & Home Technologies LIMITED WARRANTY (Cont’d)  
this noise are not covered by this warranty.  
HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main-  
tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing  
agent identification label furnished with the appliance; (2) installation which does not comply with local building codes;  
(3) shipping, improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environ-  
mental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure or handling  
devices such as exhaust fans or forced air furnaces or other such causes; (5) use of fuels other than those specified  
in the operating instructions; (6) installation or use of components not supplied with the appliance or any other compo-  
nents not expressly authorized and approved by HHT; and/or (7) modification of the appliance not expressly autho-  
rized and approved by HHT in writing.  
This warranty does not apply to non-HHT venting components, hearth components or other accessories used in con-  
junction with the installation of this product.  
This warranty is void if the appliance has been over-fired or operated in atmospheres contaminated by chlorine,  
fluorine, or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation, or  
there is any damage to the appliance or other components due to water or weather damage which is the result of, but  
not limited to, improper chimney or venting installation.  
HHT’s liability under this warranty is limited to the replacement and repair of defective components or workmanship  
during the applicable period. HHT may fully discharge all of its obligations under such warranties by repairing the  
defective component(s) at HHT’s discretion. Shipping costs are not covered under this warranty.  
Some states do not allow exclusions or limitation of incidental or consequential damages, so those limitations may not  
apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state.  
EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE  
WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF  
THE WARRANTY SPECIFIED ABOVE.  
This Limited Warranty is effective on all HHT appliances sold after September 01, 2008 and supersedes any and all war-  
ranties currently in existence.  
If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide neces-  
sary parts or components, contact the nearest authorized HHT dealer or supplier.  
4021-645A 09-01-08  
Page 47  
September 1, 2008  
7014-082D  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CONTACT INFORMATION:  
Hearth & Home Technologies  
1445 North Highway  
Colville, WA 99114  
Division of HNI INDUSTRIES  
Please contact your Quadra-Fire dealer with any questions or concerns.  
For the number of your nearest Quadra-Fire dealer  
visit our website at www.quadrafire.com  
NOTICE  
DO NOT DISCARD THIS MANUAL  
Read, understand and  
follow these instruc-  
tions for safe installa-  
tion and operation.  
Leave this manual with  
party responsible for use  
and operation.  
• Important operating and  
maintenance instruc-  
tions included.  
We recommend that you record the following pertinent  
information for your CB1200-I PELLET STOVE  
Date purchased/installed:  
Serial Number:  
Location on appliance:  
Dealer phone:  
Dealership purchased from:  
Notes:  
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876, 4793322, 4811534,  
5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983, 5429495, 5452708, 5542407,  
5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237, 5947112, 5996575, 6006743, 6019099,  
6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079, 6439226, 6484712, 6543698, 6550687, 6601579,  
6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940, 6748942, 6769426, 6774802, 6796302, 6840261, 6848441, 6863064,  
6866205, 6869278, 6875012, 6880275, 6908039, 6919884, D320652, D445174, D462436; (Canada) 1297749, 2195264, 2225408,  
2313972; (Australia) 780250, 780403, 1418504 or other U.S. and foreign patents pending.  
7014-082D  
Septemer 1, 2008  
Page 48  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grindmaster Coffeemaker P200 User Manual
Groupe SEB USA T FAL Toaster Neftis User Manual
Haier Dishwasher DW12 PFE1 ME User Manual
Hamilton Beach Cookware Cookie Press and Cake Food Decorator User Manual
Hamilton Beach Electric Grill 840081800 User Manual
Harbor Freight Tools Air Compressor 40134 User Manual
Hunter Fan Outdoor Ceiling Fan 41736 User Manual
Husqvarna Trimmer 325CX User Manual
IKEA Microwave Oven MW6 User Manual
Impex Home Gym PHC 700 User Manual