Hearth and Home Technologies Indoor Fireplace 823 0170 User Manual

R
Isle Royale  
Non-Catalytic, Top-load, Wood Heater  
Portland  
Tested and  
Listed by  
O-T L  
Oregon USA  
Models:  
823-0170  
823-0290  
C
US  
OMNI-Test Laboratories, Inc.  
This manual contains instructions for Installation, Operation & Maintenance.  
Please read this entire manual before you install and use your new room heater. Failure to follow  
instructions may result in property damage, bodily injury, or even death.  
IMPORTANT SAFETY NOTES:  
1) When installing your stove, particular attention should be paid to fire protection. If this room heater is not  
properly installed, a house fire may result. To reduce the risk of fire, follow the installation instructions. Contact  
local building or fire officials or authority having jurisdiction about restrictions, installation inspection and  
permit requirements in your area.  
2) CAUTION: Never use gasoline or gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar liquids to  
start or “freshen up” a fire in this heater. Keep all such liquids well away from heater while it is in use.  
3) During operation, if any part of the stove starts to glow, the stove is in an overfired condition. Close the air controls  
completely until the glowing has stopped. OVERFIRING VOIDS YOUR WARRANTY!  
4) Cool ashes should be disposed of carefully, using a metal container.  
5) Do not burn wet or green wood. Store wood in a dry location.  
6) DO NOT BURN GARBAGE OR FLAMMABLE FLUIDS SUCH AS GASOLINE, NAPHTHA OR ENGINE  
OIL. Do not burn treated wood, or wood with salt (driftwood, etc.). Burning materials other than wood  
(including charcoal) under adverse conditions may generate carbon monoxide in the home, resulting in  
illness or possible death.  
7) Do not permit creosote or soot to accumulate excessively in the chimney or inside the firebox.  
8) Check your chimney system thoroughly when installing into an existing metal or masonry chimney. Seek  
professional advice if in doubt about its condition.  
9) Do not connect this unit to a chimney flue already serving another appliance.  
10) Comply with all minimum clearances to combustibles as shown in this manual for this appliance.  
11) Build fire on brick firebox floor. Do not use grates, andirons or other methods to support fuel.  
12) HOT WHILE IN OPERATION! Keep children, pets, clothing and furniture away. Contact can cause skin burns.  
13) Do not connect to any air distribution duct or system  
14) RISK OF FIRE! Do not operate with stove door open, without the firescreen, or ash removal system door open.  
15) For further information refer to NFPA 211 (USA) or CAN/CSA-B365 (Canada).  
16) Do not operate without fully assembling all components. Burning your stove without the legs attached (if supplied  
with unit) will void your warranty, and could present a serious safety hazard  
17) Do not oeprate with broken glass..  
PRIOR TO FIRST FIRE: Remove all labels from glass. Clean plated surfaces with a glass cleanser and soft  
cloth to prevent staining from fingerprint oils.  
SAVE THESE INSTRUCTIONS  
1445 North Highway  
Colville, WA 99114-2008  
250-5763C September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
TABLE OF CONTENTS  
PRE-USE CHECK LIST  
Serial Number Label Location.................................2  
Pre-Use Checklist.....................................................3  
Listings & Safety Notices ........................................4  
Dimensions ...............................................................5  
Vent Specifications...................................................5  
Clearances  
Top & rear vent installations.................................6  
Floor protection....................................................7  
Locating your stove..............................................8  
Alternate floor protection calculation....................8  
Installation  
1.  
Place the unit in a location near the final instal-  
lation area and follow the procedures below.  
2.  
Open the stove and remove all the parts and  
articles packed inside. Inspect all the parts and  
cast iron body for shipping damage. Contact  
your dealer if any irregularities are noticed.  
3.  
All safety warning have been read and fol-  
lowed.  
4.  
5.  
6.  
7.  
This Owner's Manual has been read.  
Floor protection requirements have been met.  
Chimney connector is properly installed.  
Reversible flue collar............................................9  
Rear flue deflector cover plate.............................9  
Chimney height requirements & draft ..................10  
2-10-3 Rule ..........................................................10  
Flue & venting systems........................................11  
Chimney connector..............................................11  
Masonry chimney.................................................11  
Solid pack chimney with  
The proper clearances from the stove and chim-  
ney to combustibles materials have been met.  
8.  
The masonry chimney is inspected by a pro-  
fessional and is clean, or the factory-built  
metal chimney is installed according to the  
manufactuer'rs instrucitons and clearances.  
9.  
The chimney meets the required minimum  
height.  
Metal supports as a thimble.............................12-13  
Masonry fireplace.................................................14  
Metal prefabricated chimney................................15  
Mobile home installation ......................................16  
Outside air kit installation.....................................17  
Optional Blower ...................................................17  
Operation  
10.  
11.  
All labels have been removed from the glass  
doors.  
Plated surfaces have been wiped clean.  
Over-firing Your Appliance ...................................18  
Burning process...................................................18  
Air controls...........................................................19  
Heat output setting...............................................20  
Operation of top-load option ................................20  
Building a fire .......................................................21  
Opacity.................................................................21  
Burn rates ............................................................22  
Wood selection and storage.................................22  
Blower operating instructions...............................22  
Maintenance  
CAUTION!  
DO NOT TILT THE UNIT ON THE CAST IRON LEGS.  
Lift the unit upright and place it into position on the floor  
protector.  
Creosote formation & removal .............................23  
Chimney cleaning ................................................23  
Ash removal.........................................................23  
Overfring ..............................................................23  
Firebrick ...............................................................23  
Glass care & replacement....................................24  
Plated Surfaces....................................................24  
Brick replacement ................................................25  
Door & gasket .....................................................25  
Service & Maintenance Log.....................................26  
Exploded views.........................................................27  
Service Part & Accessories.....................................28  
Warranty................................................................30-31  
Contact Information .................................................32  
Page 3  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
LISTINGS and SAFETY NOTICES  
FIRE SAFETY: To provide reasonable fire safety, the following  
should be given serious consideration:  
These installation instructions describe the installation and opera-  
tion of the QUADRA-FIRE ISLE ROYALE woodstove. This stove  
meets the U.S. Environmental ProtectionAgency’s 1990 particulate  
emission standards. The stove is listed by OMNI-Test Laborato-  
ries, Inc. to UL Safety Standard 1482, and ULC S627, and (UM)  
84-HUD., Report number 061-S-18-2. This stove is approved for  
mobile home installations when not installed in a sleeping room and  
when an outside combustion air inlet is provided. The structural  
integrity of the mobile home floor, ceiling, and walls must be main-  
tained. The stove must be properly grounded to the frame of the  
mobile home and only use listed double-wall pipe. Outside Air Kit,  
Part 831-1780 must be installed in a mobile home installation.  
1. Install at least one smoke detector on each floor of your  
home to ensure your safety. They should be located away  
from the heating appliance and close to the sleeping areas.  
Follow the smoke detector manufacturer’s placement and  
installation instructions, and be sure to maintain regularly.  
2.  
3.  
4.  
Aconveniently located ClassAre extinguisher to contend  
with small fires resulting from burning embers.  
A practiced evacuation plan, consisting of at least two  
escape routes.  
Check with your local building code agency before you begin your  
installation to ensure compliance with local codes, including the  
need for permits and follow-up inspections. Be sure local build-  
ing codes do not supersede UL specifications and always obtain  
a building permit so that insurance protection benefits cannot be  
unexpectedly cancelled. If any assistance is required during instal-  
lation, please contact your local dealer.  
A plan to deal with a chimney fire as follows:  
In the event of a chimney fire:  
A. Notify fire department.  
B. Prepare occupants for immediate evacuation.  
C. Close all openings into the stove.  
D. While awaiting fire department, watch for ignition of  
adjacent combustibles from overheated stove pipe,  
hot embers or sparks from the chimney.  
Inspect and clean vent system frequently in accordance with the  
instructions contained in this manual. Do not connect this unit to  
a chimney serving another appliance.  
When using optional Blower, Part 831-1701, route power cord away  
from unit. Do not route cord under or in front of appliance.  
VENTING SYSTEM  
The venting system consists of a chimney connector and a  
chimney. These get extremely hot during use. Temperatures  
inside the chimney may exceed 2000°F (1100°C) in the event of  
a creosote fire. To protect against the possibility of a house fire,  
the chimney connector and chimney must be properly installed  
and maintained. An approved thimble must be used when a  
connection is made through a combustible wall to a chimney.  
A chimney support package must be used when a connection  
is made through the ceiling to a prefabricated chimney. These  
accessories are absolutely necessary to provide safe clearances  
to combustible wall and ceiling material. Follow venting  
manufacturer’s clearances when installing venting system.  
Do not elevate fire. Build wood fire directly on firebrick.  
Do not overfire - if heater or chimney connector glows, you are  
overfiring. Stove thermometer recommended.  
Operate only with the door closed unless using a firescreen. Open  
only to add fuel to the fire. Operating with the door open can cause  
hot embers or sparks to fall out and a fire may result.  
INSTALLATION MATERIALS NEEDED FOR YOUR SAFETY  
CHIMNEY CONNECTOR (also known as flue pipe or stove pipe):  
The chimney connector joins the stove to the chimney (see page  
11). It must be 6 inch (152mm) minimum diameter 24 MSG black  
or blued steel, or an approved air-insulated double wall venting  
pipe.  
THIMBLE: A manufactured or site-constructed device installed in  
combustible walls through which the chimney connector passes  
to the chimney (see page 11-12). It is intended to keep the  
walls from igniting.  
This stove may be connected to a lined masonry chimney or a  
listed high temperature prefabricated approved metal chimney.  
Do not connect it to a chimney serving another appliance. To do  
so will affect the safe operation of both appliances.  
WARNING! NEVER DRAW OUTSIDE COMBUSTION AIR FROM A  
WALL, FLOOR OR CEILING CAVITY OR FROM ANY ENCLOSED  
SPACE SUCH AS AN ATTIC OR GARAGE.  
CHIMNEY SYSTEMS:  
1. APPROVED MASONRY(see specifications on page 14) with  
at least 5/8 inch (16mm) fire clay lining joined with refractory  
cement or other listed system suitable for use with wood  
stoves.  
WARNING ! DO NOT ATTEMPT TO OPERATE THIS WOODSTOVE  
WITHOUT READING AND UNDERSTANDING THESE OPERATING  
INSTRUCTIONS THOROUGHLY. FAILURE TO OPERATE THIS  
APPLIANCE PROPERLY MAY CAUSE A HOUSE FIRE.  
2. PREFABRICATED 6 inch (152mm) listed high temperature  
(UL 103 HT or ULC S629) chimney. Components required  
by manufacturers for installation such as the chimney support  
base, firestop (as appropriate), attic insulation shield, insulated  
tee, etc., are necessary to assure a safe chimney installation.  
Use only components manufactured for the chimney. Chimney  
installation should meet NFPA 211 standards.  
WARNING ! THE OUTSIDE SURFACES OF THIS UNIT WILLBECOME  
ExTREMELY HOT DURING USE. ALWAYS KEEP CHILDREN AWAY  
WHILE IT IS OPERATING AND DO NOT LET ANYONE OPERATE  
THIS APPLIANCE UNLESS THEY ARE FAMILIAR WITH THESE  
OPERATION INSTRUCTIONS.  
Page 4  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
DIMENSIONS  
SIDE VIEW  
FRONT VIEW  
22-3/4" (578mm)  
29" (737mm)  
16-3/4"  
(425mm)  
C
L
30"  
(762mm)  
30" (762mm  
26-7/16"  
(570mm)  
8-1/4"  
(210mm)  
16-1/2"  
(419mm)  
28-3/4" (730mm)  
24-5/8" (625mm)  
VENT SPECIFICATIONS:  
Single Wall: Six inch (6") (152mm) diameter, minimum 24 MSG black or blued steel connector pipe, with a listed factory-built  
chimney type UL103 HT* suitable for use with solid fuels, or a masonry chimney, and the referenced clearances.  
Double Wall/Mobile Home: Six inch (6”) (152mm) diameter, listed double wall air insulated connector pipe with listed  
factory-built UL103 HT* Class “A” chimney, or a masonry chimney (Mobile Home must be equipped with a spark arrestor),  
and the referenced clearances. Use only double-wall connector pipe, Dura-Vent DVL, Selkirk metalbestos DS, Security DL  
double wall connector or any listed double-wall connector pipe.  
*In Canada must comply with CAN/ULC-S629 or the 650° Factory-built chimney.  
Page 5  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
CLEARANCES TO COMBUSTIBLES (UL and ULC)  
C
A
B
H
8" max  
D
ceiling  
G
Ceiling  
G
mantel  
G
C
L
26-7/16"  
(672mm)  
E
F
I
F
E
MINIMUM CLEARANCES TO COMBUSTIBLE MATERIALS In Inches & (Millimeters)  
NOTE: "A" ,"C" and "F" Dimensions are to the inside diameter of the flue collar.  
OMNI Test Laboratories, Inc Report Ntumber 061-S-18-2  
A
C
I
B
E
F
D
G
H
FOR TOP VENT INSTALLATIONS:  
SINGLE WALL PIPE  
18 (457)  
18 (457)  
16 (406)  
53 (1346)  
53 (1346)  
28 (711)  
12 (305)  
22 (558)  
6 (153)  
33 (838)  
29 (737)  
16 (406)  
22 (558)  
18 (457)  
15 (381)  
13 (333)  
DOUBLE WALL PIPE  
14 (356)  
14 (356)  
INSTALLATION: ALCOVE Six inch (6") (152mm) diameter listed Double Wall air insulated connector pipe with UL 103 HT listed  
factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be equipped with a spark arrestor). Maximum depth of Alcove  
shall be no more than 48 inch(1220mm). Please refer to the clearances below for minimum Alcove height requirements to top of unit.  
18 (457)  
53 (1346)  
N/A  
14 (356)  
29 (737)  
N/A  
14 (356)  
18 (457)  
13 (333)  
DOUBLE WALL PIPE  
FOR REAR VENT INSTALLATIO  
NS:  
IN A MASONRY FIREPLACE OR THROUGH THE WALL: Six inch (6") (152mm) diameter listed double wall air insulated  
connector pipe with UL 103HT listed factory-built Class "A" chimney, or a masonry chimney. (Mobile Home must be  
equipped with a spark arrestor). Additonal specifications include a maximum 8 inch (203mm) deep mantel without  
heat shield and the following clearances.  
A
C
F
B
D
E
G
H
I
ceiling  
mantel  
N/A  
36 (914)  
14 (356)*  
N/A  
N/A  
N/A  
33 (838)  
22 (558)  
14 (356) 9 (229)  
0 (00) In Masonry Wall  
N/A)  
*
(G mantel) with shield spaced 1 inch (25mm) away from bottom mantel surface.  
Page 6  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
FLOOR PROTECTION  
The floor must be non-combustible material, extending beneath heater and to the front, sides and rear as indicated. The  
floor must be non-combustible or otherwise adequately protected from radiant heat given off by the unit and from sparks  
and falling embers. A layer of thin brick or ceramic tile over a combustible floor is not sufficient. See Alternate floor protec-  
tion calculation sample on page 8.  
In USA installations, it is necessary to install a floor protector 16 inches in front and 8 inches to both sides of the loading  
door. See *exception below.  
In Canada, similar floor protection must be provided 18 inches (457mm) in front and 8 inches (203mm) from the sides and  
rear of the stove. See *exception below.  
*ExCEPTION: Non combustile floor protections must extend beneath the flue pipe when installed with horizontal venting  
and extend 2 inches (51mm) beyond each side.  
203mm (8")  
203mm  
(8")  
203mm  
(8")  
Fuel loading door  
1251mm  
(49-1/4")  
Minimum  
39-1/4"  
Minimum  
16" from glass - std legs  
8"  
457mm (18")  
CANADA  
USA  
1137mm (44-3/4")  
Minimum  
36-3/4"  
Minimum  
51"  
51"  
must extend  
length of flue and  
2" (51mm)  
beyond each  
side of pipe  
USA - Required  
CANADA - Recommended  
USA Installations  
Page 7  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Calculating Alternate Floor Protection  
LOCATING YOUR STOVE  
Material  
WHEN LOCATING YOUR STOVE consider safety, conve-  
nience, traffic flow, and the fact that the stove will need a  
chimney and chimney connector. It is a good idea to plan  
your installation on paper, using exact measurements for  
clearances and floor protection, before actually beginning the  
installation. If you’re not using an existing chimney, place the  
stove where there will be a clear passage for a factory-built  
listed chimney through the ceiling and roof.  
Thermal Conductivity: k value  
The k value indicates the amount of heat (in BTU’s) that will flow  
in 1 hour through 1 square foot of a uniform material 1 inch thick  
for each degree (F) of temperature difference from one side of  
the material to the other. The LOWER the k factor means less  
heat is being conducted through the non-combustible material  
to the combustible material beneath it. The k value of a mate-  
rial must be equal or smaller then the required k value to be  
acceptable.  
AVOID FIRE: Maintain the designated clearances to combus-  
tibles. Insulation must not touch the chimney. You must main-  
tain the designated air space clearance around the chimney.  
This space around a chimney is necessary to allow natural  
heat removal from the area. Insulation in this space will  
cause a heat buildup, which may ignite wood framing. NOTE:  
Clearances may only be reduced by means approved by  
the regulatory authority having jurisdiction.  
(BTU) (inch)  
(foot2 (hour) (oF)  
Thermal Resistance: R value  
The R value is a measure of a material’s resisteance to  
heat transfer. R value is convenient when more than one  
material is used since you can add the R values together,  
whereas you can not do this for k value. The HIGHER the R  
factor means less heat is being conducted through the non-  
combustible material to the combustible material beneath it.  
The R value of a material must be equal or larger then the  
required R value to be acceptable.  
WE RECOMMEND that you have a qualified building inspec-  
tor and your insurance company representative review your  
plans before and after installation.  
Converting k to R:  
Divide 1 by k and multiply the results times the thickness in  
inches of the material.  
R = 1/k x inches of thickness  
Converting R to k:  
Divide the inches of thickness by R.  
k = inches of thickness/R  
Calculatons:  
Example: Floor protection requires k value of 0.84 and 3/4 inch  
thick.  
Alternative material has a k value of 0.6 and is 3/4 inch thick.  
Divide 0.6 by .75 = k value of 0.80. This k value is smaller than  
0.84 and therefore is acceptable.  
Page 8  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
REAR FLUE DEFLECTOR COVER PLATE  
REVERSIBLE FLUE COLLAR  
This cover plate is used when the flue collar is turned for a  
rear vent application.  
The flue collar is reversible for either a top or rear venting  
installation. The unit is shipped with the flue collar in the top  
vent position.  
Please note this cover plate will not  
work with the Low-Profile Kit  
CONVERTING COLLAR FOR REAR VENT INSTALLATION  
1. Remove 5 Phillips head screws from the rear shield, lift  
shield up and set aside.  
2. Remove bolts from each side of the flue transition (2  
total). (Place your free hand in flue opening to locate  
and retrieve nuts attached to bolts.)  
3. Turn vent to horizontal position. Inspect sealant to ensure  
a leak free application.  
4. Re-assemble in reverse order.  
Mounting Screws  
1. After the flue collar has been reversed for a rear vent  
installation, install the cover plate on the stove with the  
two screws provided.  
Bend Flange Down  
2. Bend the cover plate flange down.  
3. Secure the cover plate with the remaining two screws.  
Page 9  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Three factors work together as a system to create the flue  
draft; 1) availability of combustion air; 2) heat generated  
from the fire, and 3) diameter and height of the flue system..  
Increasing or decreasing any one of them will affect the  
other two and thus change the amount of draft in the entire  
system.  
CHIMNEY HEIGHT REQUIREMENTS / DRAFT  
To be sure that your stove burns properly, the chimney draft  
(static pressure) should be approximately -.04” water column  
(W.C.) during a low burn and -.10” W.C. during a high burn,  
measured 6 inches (152mm) above the top of the stove after  
one hour of operation at each burn setting.  
Asource of air (oxygen) is necessary in order for combustion  
to take place. The combustion air enters the firebox below  
the ash catcher and is directed to the upper front of the fire-  
box. These openings are regulated by the Primary Air Slide  
Control and Start-up Air Control, (see page 18 for operation  
of these controls). It is important to realize that whatever  
combustion air is consumed by the fire must be replaced.  
If you are using room air, the air is replaced via air leakage  
that occurs around windows and under doors, etc. However,  
in most newly constructed houses, mobile homes, or even  
existing homes that are fitted with tightly sealed doors and  
windows, the area from which the combustion air is taken  
is relatively air tight. In these cases, an outside air source  
must be made available to feed combustion air from outside  
the home into the stove. An Outside Air Kit is available as  
an option, Part 831-1780. The kit is a requirement for mobile  
home installations.  
NOTE: These are guidelines only, and may vary somewhat  
for individual installations.  
The stove was designed for and tested on a 6 inch (152mm)  
chimney, 12 ft.-14 ft. (360-420cm) high, measured from the  
base of the stove. The further your stack height or diameter  
varies from this configuration, the possibility of performance  
problems increases. In addition, exterior conditions such as  
roof line, surrounding trees, prevailing winds and nearby hills  
can influence stove performance.  
A masonry chimney or a listed factory-built UL103 HT Class  
“A” chimney must be the required height above the roof  
and any other nearby obstructions. The chimney must be  
at least 3 ft. (91cm) higher than the highest point where it  
passes through the roof and at least 2 ft. (61cm) higher than  
the highest part of the roof or structure that is within 10 ft.  
(305cm) of the chimney, measured horizontally. See 2-10-3  
Rule below.  
A specific volume of air, determined by the diameter and  
height of the chimney connector and chimney, is contained  
within the flue system. As heat from the fire enters the flue,  
it warms this air causing it to rise. The air moving up the  
flue draws smoke and more heated air from the fire with it,  
thus establishing draft. The amount of draft depends on the  
temperature of the heated air and the volume of air that is  
contained in the flue system.  
These are safety requirements and are not meant to  
assure proper flue draft.  
We recommend using a minimum total system height of 12  
ft. (360cm), measured from the flue collar to the top of the  
chimney (not including chimney cap).  
If the fire is difficult to start, and smoke spills out of the door,  
or you find it hard to establish and maintain a moderately  
high burn rate, then the flue draft is too low and corrective  
measures must be taken.  
2-10-3 RULE  
2 ft Min (61cm)  
3 ft Min  
If you still suspect you have a low draft problem, it may be  
necessary to increase the volume of air in your flue system.  
Since the diameter of your flue system is matched with the  
size of the flue collar and should not be changed, the height  
of the system will need to be increased. Add chimney a little  
at a time until the draft improves, and ensure that the flue  
collar and venting section are sealed.  
(91cm)  
10 ft Min  
(305cm)  
Your local dealer is the expert in your geographic area and  
can usually make suggestions or discover problems that will  
easily correct your flue draft problem, allowing your wood-  
stove and its flue system to operate correctly and provide  
safe and economical heat for your home.  
A proper amount of flue draft is required to assure the safe  
and efficient operation of the this woodstove. Flue draft is  
measured as negative pressure in the chimney. The amount  
of negative pressure determines the strength of the draft.  
This draft performs two important roles in the operation of  
the woodstove. It draws the combustion air into the firebox,  
and pulls the smoke out of the chimney.  
Page 10  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
The flue should be checked to determine that it is not too large  
FLUE SYSTEMS  
for the stove. NFPA 211 allows the cross-sectional area of  
the flue to be no more than 3 times the cross-sectional area  
of the flue collar of the stove (28 x 3 = 84 square inches). It  
is recommended that a chimney with a larger diameter be  
relined, since the oversized flue can cause poor performance  
and contribute to the accumulation of creosote. (See page 10  
for more information about troubleshooting draft problems).  
There are two separate and different parts to a flue system: the  
chimney connector and the chimney itself.  
1. Single wall connector or stovepipe. This must be at least  
24 gauge mild steel or 26 gauge blue steel. The sections  
must be attached to the stove and to each other with the  
crimped (male) end pointing toward the stove. See Figure  
11A. All joints, including the connection at the stove collar,  
should be secured with three sheet metal screws. Make  
sure to follow the minimum clearances to combustibles as  
set out on pages 6 and 7 of this manual. Where passage  
through the wall, or partition of combustible construction  
is desired, the installation shall conform to CAN/CSA-  
B365.  
CAUTION! DO NOT CONNECT THIS UNIT TO A  
CHIMNEY FLUE SERVING ANOTHER APPLIANCE.  
When connecting the stove through a combustible wall to a  
masonry chimney, special methods are needed. There are  
several ways to make this connection, including the construc-  
tion of a masonry thimble. This installation shall conform to  
CAN/CSA-B365. Check with your local building authorities  
or consult the National Fire Protection Association (NFPA  
211). Refer to Figure 12B (page 12) and Figures 13A &  
13B (page 13).  
2. Factory-built listed chimney connector (vented). A listed  
connector (vented) must be used when installing this unit  
in a mobile home. A listed chimney and listed connector  
must be used. they must conform to each other to ensure  
a proper fit and seal.  
Wood Stud 2"  
(51mm)  
Clearance  
Fireclay liner 5/8"  
from chimney  
(16mm) Minimum  
wall  
or Equivalent.  
CRIMPED  
END  
TOWARDS  
STOVE  
FLUE  
GAS  
DIRECTION  
Header  
Figure 11A - Chimney Connector  
MASONRY CHIMNEY  
Fireclay liner 5/8"  
(16mm) Minimum  
or Equivalent.  
For optimal performance, masonry chimneys used to vent this  
appliance should be lined with a 6 inch stainless steel liner.  
Installations into a clay flue without a stainless steel liner may  
reduce efficiency, cause the glass to darken, and produce  
excessive creosote.  
Sill support  
Ensure that a masonry chimney meets the minimum standards  
of the National Fire Protection Association (NFPA) Standard  
211. It must have at least a 5/8 inch (16mm) fire clay liner or  
a listed chimney liner system. See Figure 11B. Make sure  
there are no cracks, loose mortar or other signs of deteriora-  
tion and blockage. It is best to have the chimney inspected  
by a professional and be sure to have the chimney cleaned  
before the stove is installed and operated.  
Thimble Assembly:  
12" (305mm) of brick  
separation between  
clay liner and  
combustibles.  
Figure 11B  
WARNING! IF INSTALLING THIS MODEL TO A MASONRY CHIMNEY, ALWAYS BE SURE THE CHIMNEY IS IN GOOD CONDITION AND THAT IT  
MEETS THE MINIMUM STANDARDS OF THE NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) STANDARD 211.  
THIS APPLIANCE IS MADE WITH A 6 INCH/152mm DIAMETER CHIMNEY CONNECTOR AS THE FLUE COLLAR ON THE UNIT. CHANGING  
THE DIAMETER OF THE CHIMNEY CAN AFFECT DRAFT AND CAUSE POOR PERFORMANCE. IT IS NOT RECOMMENDED TO USE  
offSetS or elbowS at altitudeS aboVe 4000 feet aboVe Sea leVel or when there are other factorS that affect  
FLUE DRAFT.  
Page 11  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE  
For the method of installation to a masonry chimney shown in Figures 13A & 13B, (page 13) it will be necessary to purchase  
a 12 inch (305mm) long 8 inch (203mm) inside diametert, section of prefabricated listed solid pack chimney to use as a  
thimble. Purchase a wall spacer, trim collar, and a wall band manufactured to fit the chimney section you purchase.  
The safety features of this system are two fold: 1) a 2 inch (51mm) air space between the chimney section and combustible  
wall; and, 2) the 1 inch (25mm) air space around the chimney connector as it passes through the chimney section to the  
chimney.  
The location of the opening through the wall to the chimney must leave a minimum 18 inches (457mm) vertical clearance  
between the connector pipe and the ceiling to prevent the ceiling from catching fire.  
Measure as shown in Figure 12A. Cut an opening in the wall large enough to accommodate the outside dimension of the  
chimney section plus the minimum air space specified by its manufacturer. It may be necessary to cut the wall studs and  
install a header and a sill frame to maintain the wall support. The hole in the chimney must have at least an 8 inch (203mm)  
diameter fire clay liner or equivalent, secured with refractory mortar. If it is necessary to cut a hole in the chimney liner, use  
extreme care to keep it from shattering.  
FIRECLAY FLUE LINER  
WITH AIR SPACE  
CONCRETE CAP  
C
L
RAFTER  
26-7/16"  
(570mm)  
FLASHING  
1" (25mm)  
CLEARANCE  
WITH FIRESTOP  
CEILING JOIST  
EAVE  
COMBUSTIBLE WALL  
1" (25mm)  
CLEARANCE  
Wall  
Center of Hole  
Opening  
THIMBLE,  
12" (305mm)  
OF BRICK  
Center Line  
SHEATHING  
Center Line  
FLOOR PROTECTOR  
Add the 26-7/16 inches (671mm), center-line  
measurement to the depth measurement of  
your floor protector. Mark this combined mea-  
surement at the correct wall location for your  
installation, maintaining minimum clearance to  
combustibles.  
AIRTIGHT  
CLEANOUT DOOR  
Figure 12A  
Figure 12B  
WARNING! ALWAYS FOLLOW CHIMNEY CONNECTOR MANUFACTURER’S INSTRUCTIONS FOR PROPER INSTALLATION.  
CHIMNEY CONNECTOR IS TO BE USED ONLY WITHIN THE ROOM, BETWEEN THE STOVE AND CEILING OR WALL, NEVER  
PASSING THROUGH A COMBUSTIBLE CEILING OR WALL. THE CONNECTOR SHALL NOT PASS THROUGH AN ATTIC OR  
ROOF SPACE, CLOSET OR SIMILAR CONCEALED SPACE, OR A FLOOR, OR CEILING. MAINTAIN MINIMUM CLEARANCES  
TO COMBUSTIBLES AS REFERENCED ON PAGES 6 & 7.  
Page 12  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
SOLID PACK CHIMNEY WITH METAL SUPPORTS AS A THIMBLE (CONT'D)  
First, make the frame for the thimble, ensuring it  
Min. Chimney Clearance  
to Wall Spacer and  
Combustibles - 2" (51mm)  
is no smaller than 14 inches (356mm) square to  
maintain a 2 inch (51mm) air space around the  
chimney section.  
Min. Clearance  
2" (51mm)  
1" (25mm) Air Space  
Attach the wall spacer to the chimney side of the  
frame. Then insert the frame into the opening, toe  
nailing it to the wall studs. Install the wall band in the  
framing to secure the chimney section in place.  
to Chimney Section  
Chimney Flue Liner  
Fireclay  
Liner or  
Equivalent  
Chimney  
Connector  
Insert a single section of chimney connector into the  
chimney through the wall band, being sure it does  
not protrude into the chimney beyond the edge of  
the chimney flue lining.  
Chimney Section  
Trim Collar  
Wall Band  
Wall Spacer  
Masonry Chimney  
Constructed to NFPA 211  
Apply high temperature furnace cement to the end  
of the chimney section and install it over the con-  
nector, through the wall spacer. Tighten the wall  
band to hold the chimney section firmly in place and  
against the chimney.  
Figure 13A  
Install the trim collar on the outside of the opening.  
Check to ensure there is a 1 inch (25mm) air space  
between the connector and the chimney section.  
During installation ensure that a 2 inch (51mm) air  
space to the wood framing is maintained. Do not  
fill this space with insulation. Insulation in this air  
space will cause a heat buildup which may ignite  
the wood framing.  
Fire Clay  
Flue Liner  
with Airspace  
Masonry  
Chimney  
Trim Collar  
Wall Spacer  
Chimney Section  
with 2" (51mm)  
Clearance to  
Wall Band to  
Secure Chimney  
Section  
Combustibles  
Chimney  
Connector  
Wood Studs Used for  
Framing - Spaced 2"  
(51mm) clearance from  
Masonry Chimney  
Figure 13B  
Page 13  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
CONNECTION TO A MASONRY FIREPLACE  
There are several kits available to connect the stove to a  
NOTE: For instances with a fireplace measuring less than  
30 inches in height, Hearth Legs (see Accessories on page  
25) or Horizontal Flue Kit, Part 834-3790, may be ordered  
to complete the masonry fireplace installation.  
masonry fireplace. Look for a listed kit. The kit is an adapter  
which is installed at the location of the fireplace damper. The  
existing damper may have to be removed to allow installation  
of the kit. The key points of this type of stove connection are  
that the connector pipe must extend up the chimney above  
where the fire clay liner starts, and the areas of the kit instal-  
lation and penetration should fit tightly and be sealed with  
high temperature furnace cement unless the kit’s instructions  
state otherwise. figure 14a. The tight fitting installation aids  
the proper draw of the chimney.  
Support Plate & Clamp  
Fireclay liner 5/8"  
(16mm) Minimum or  
Equivalent.  
Listed Rigid  
Stainless Liner  
Carry Stovepipe  
Above the Liner  
Stainless Steel  
Flex Section  
Damper Plate is  
Removed or  
Fastened in Open  
Position  
Stainless Tee with Cleanout  
Stainless Connector Pipe  
Use Damper Adapter or  
Seal With Sheetmetal  
and Sealant  
6
Cleanout  
Figure 14a  
Page 14  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
CONNECTION TO A METAL PREFABRICATED CHIMNEY  
When a metal prefabricated chimney is used, the manufac-  
turer’s installation instructions must be followed precisely.  
It will be necessary to install the ceiling support package  
or wall pass through, “T” section package, firestops (when  
needed), insulation shield, roof flashing, chimney cap, and  
any other materials deemed necessary by the instructions  
of manufacturer of the prefabricated chimney. Maintain  
the proper clearance to the structure as recommended by  
the manufacturer. This clearance is usually a minimum of  
2 inch (51mm), although it may vary by manufacturer or for  
certain components. Follow the manufacturers’ instructions  
carefully.  
Combustible Outside Wall  
Maintain 2" (51mm)  
Clearance Through Eave  
Listed  
Chimney Pipe  
Listed Cap  
2" (51mm)  
Clearance  
Chimney  
Connector  
Listed Chimney  
Flashing  
To Stove  
Insulated "T"  
Wall Support  
Trim Collar  
on Inside  
Wall  
Wall Spacer on  
Outside Wall  
*
Combustible  
Ceiling  
Insulated "T"  
Chimney  
Connector  
There are basically two methods of metal chimney instal-  
lation. One method is to install the chimney inside the  
residence through the ceiling and the roof. Install an attic  
insulation shield to maintain the specified clearance to insu-  
lation. Insulation in this air space will cause a heat buildup  
which may ignite the ceiling joists. This method of installa-  
tion requires, at minimum, a ceiling support package, an  
insulation shield and roof flashing. Figure 15A.  
*
*
Combustible Wall  
Floor  
Protector  
*Refer to Clearances to Combustibles  
The other method is to install an exterior chimney that runs  
up the outside of the residence. See Figure 15B. The  
components illustrated may not look exactly like the system  
you purchase, but they demonstrate the basic components  
necessary for a proper and safe installation.  
Figure 15A - Exterior Chimney  
Listed  
Chimney  
The chimney must be the required height above the roof or  
other obstruction for safety and for proper draft operation.  
The requirement is that the chimney must be at least 3 ft.  
(91cm) higher than the highest point where it passes through  
the roof and at least 2 ft (61cm) higher than the highest part  
of the roof or structure that is within 10 ft. (305cm) of the  
chimney, measured horizontally. (See page 10)  
Attic  
Insulation  
Shield  
Listed Cap  
Combustible  
Ceiling  
Joists  
Maintain 2" (51mm)  
Storm Collar  
Flashing  
Specified  
Clearance  
Chimney  
Connector  
Listed Chimney  
Ceiling Support  
To Stove  
IMPORTANT! FOLLOW MANUFACTUR-  
ERS’ INSTALLATION INSTRUCTIONS AND  
MAINTAIN CLEARANCES AS SPECIFIED  
ON PAGES 6 & 7.  
Combustible Wall  
Chimney  
Connector  
*Refer to Clearances  
to Combustibles  
Floor  
Protector  
In Canada, when using a factory-built chimney,  
make sure it is safety listed, Type UL 103 HT  
CLASS "A" or conforming to CAN/ULC-S629,  
STANDARD FOR 650°C FACTORY-BUILT CHIM-  
NEYS.  
Figure 15B- Interior Chimney  
Page 15  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
MOBILE HOME INSTALLATION  
You must use a Quadra-Fire Outside Air Kit Part 831-1780 for installation in a mobile home.  
1. An outside air inlet must be provided for combustion and must remain  
clear of leaves, debris, ice and/or snow. It must be unrestricted while  
stove is in use to prevent room air starvation which can cause smoke  
Spark Arestor Cap  
spillage and an inability to maintain a fire. Smoke spillage can also  
set off smoke alarms.  
Storm Collar  
2. Stove must be secured to the mobile home structure. Use 1/4 inch  
(6mm) lag bolts with the appropriate length for your installation to secure  
stove through pad and into floor.  
Roof Flashing  
3. Stove must be grounded with #8 solid copper grounding wire  
or equivalent and terminated at each end with N.E.C. approved  
grounding device.  
Joist Shield/Firestop  
Listed Chimney  
Connector  
4. Stove must be installed with an approved UL103 HT ventilated  
chimney connector, UL103 HT chimney, and terminal cap with spark  
arrestor. Never use a single wall connector (stove pipe) in a mobile  
home installation. Use only double-wall connector pipe, Dura-Vent  
DVL, Selkirk metalbestos DS, Security DL double wall connector or  
any listed double wall pipe connector.  
Outside Air Kit Connector  
5. Refer to page 6 of this manual or the Serial Number label on the  
Floor Protector  
back of the stove for clearances to combustibles.  
6. Floor protections requirements on page 7 must be followed  
precisely.  
Outside Air Floor Vent  
7. In Canada, this appliance must be connected to a 6 inch (152mm)  
factory-built chimney conforming to CAN/ULC-629M, STANDARD  
FOR FACTORY BUILT CHIMNEYS. Floor protection referenced on  
page 7 must be followed.  
WARNING: NEVER DRAW COMBUSTION AIR  
FROM A WALL, FLOOR OR CEILING CAVITY  
OR FROM ANY ENCLOSED SPACE SUCH AS  
AN ATTIC OR GARAGE.  
8. Use silicone to create an effective vapor barrier at the location  
where the chimney or other component penetrates to the exterior  
of the structure.  
CAUTION: THE STRUCTURAL INTEGRITY  
OF THE MOBILE HOME FLOOR, WALL AND  
CEILING/ROOF MUST BE MAINTAINED. (i.e.,  
DO NOT CUT THROUGH FLOOR JOIST, WALL  
STUD, CEILING TRUSS, ETC.)  
9. Follow the chimney and chimney connector manufacturer’s instructions  
when installing the flue system for use in a mobile home.  
NOTE: Offsets from the vertical, not exceeding 45°, are allowed per  
Section 905(a) of the Uniform Mechanical Code (UMC). Offsets  
greater than 45° are considered horizontal and are also allowed,  
providing the horizontal run does not exceed 75% of the vertical  
height of the vent. Construction, clearance and termination must  
be in compliance with the UMC Table 9C. This installation also  
complies with NFPA 211.  
WARNING: DO NOT INSTALL  
IN SLEEPING ROOM.  
NOTE: Top sections of chimney must be removable to allow maximum clearance of 13.5 ft. (411cm) from ground level for  
transportation purposes.  
10. Burn wood only. Other types of fuels may generate poisonous gases (e.g., carbon monoxide).  
11 If unit burns poorly while exhaust blower is on in home, (i.e. kitchen range hood) increase combustion air.  
Page 16  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
OUTSIDE AIR KIT INSTALLATION  
Included in Kit: 1 flex flange; 2 cable ties; oustide air  
termination cap; mounting screws (Discard the remaining  
parts).  
Items Needed for Installation: 4 inch (102mm) diameter  
flex pipe in the length as required for your installation;  
Phillips screwdriver; Silicone sealant; Drills and saws  
necessary for cutting holes through the wall or flooring  
in your home.  
1. Remove all materials from packing box.  
OUTSIDE AIR  
TERMINATION CAP  
(contains rodent screen)  
2. Mount the flex flange (with pipe fitting extending out),  
over the intake air opening at the rear of stove using the  
four mounting screws supplied with kit.  
3. Cut a 4 inch (102mm) minimum hole in the floor or wall  
to accommodate outside air piping. Use 4 inch (102mm)  
metal flex or rigid piping to directly connect outside air to  
the unit or into vented crawl space. (Do not put flex into  
a non-vented crawl space). If using flex tubing attach  
cable ties to secure tubing at both ends. Use the supplied  
termination cap with a rodent screen. Seal between the  
floor or wall and the pipe with silicone to prevent moisture  
penetration.  
FLEX FLANGE  
NOTE: If you plan to install the optional blower and the  
outside air kit, complete installation of the outside  
air kit first.  
INSTALLATION OF OPTIONAL BLOWER  
The blower is shipped fully assembled and ready for installation.  
*The blower speed control for this unit is adjusted at the factory,  
and normally does not require further adjustment.  
1. Remove 3 Phillips head screws from rear of unit.  
2. Using the Phillips head screws, attach blower to lower rear  
of stove, as shown.  
3. Plug blower cord into a grounded outlet. Do not remove  
ground prong from plug. Route power cord to avoid heat  
from the stove, or other damage. Do not route cord under  
or in front of appliance.  
Rear Shield  
4. Adjust the blower speed control to the desired speed.  
Blower Mounting  
Flange  
ADJUSTING THE BLOWER SPEED CONTROL,*  
If Necessary  
NOTE: When the speed control is turned clockwise, it will click on  
to high speed. Turn the speed control clockwise to decrease  
the speed. At full clockwise, the blower should blow gently,  
but should not stop.  
Blower Speed Control  
Blower  
Mounting  
Flange  
1. With the unit plugged in, turn the speed control knob to slow  
(full clockwise).  
2. With a small screwdriver, adjust the blower speed by turning  
the adjustment mechanism through the hole on the side of  
the speed control.  
Rear  
Shield  
3. Adjust the speed so the blower runs slowly, but does not stop.  
Turn clockwise to slow the blower and counterclockwise to  
increase the speed.  
Page 17  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
OPERATING INSTRUCTIONS  
IMPORTANT - PLEASE READ BEFORE USING STOVE  
OVER-FIRING YOUR APPLIANCE  
BURNING PROCESS  
In recent years there has been an increasing concern about  
air quality. Much of the blame for poor air quality has been  
placed on the burning of wood for home heating. In order  
to improve the situation, we at Quadra-Fire have developed  
cleaner-burning wood stoves that surpass the requirements  
for emissions established by our governing agencies. These  
wood stoves, like any other appliances, must be properly  
operated in order to insure that they perform the way they  
are designed to perform. Improper operation can turn most  
any wood stove into a smoldering environmental hazard.  
WARNING  
Fire Risk  
Do not over-fire.  
Over-firing may ignite creosote or will damage  
the stove and chimney.  
To prevent over-firing your stove, DO NOT:  
Use flammable liquids  
Overload with wood  
Burn trash or large amounts of scrap lumber  
Permit too much air to the fire  
KINDLING or 1st STAGE  
It helps to know a little about the actual process of burning in  
order to understand what goes on inside a stove. The first  
stage of burning is called the kindling stage. In this stage, the  
wood is heated to a temperature high enough to evaporate  
the moisture which is present in all wood. The wood will  
reach the boiling point of water (212°F / 100C) and will not  
get any hotter until the water is evaporated. This process  
takes heat from the coals and tends to cool the stove.  
1. Symptoms of Over-Firing  
Symptoms of over-firing may include one or more of the  
following:  
• Chimney connector or appliance glowing  
• Roaring, rumbling noises  
• Loud cracking or banging sounds  
• Metal warping  
Fire requires three things to burn: fuel, air and heat. So,  
if heat is robbed from the stove during the drying stage,  
the new load of wood has reduced the chances for a good  
clean burn. For this reason, it is always best to burn dry,  
seasoned firewood. When the wood isn’t dry, you must open  
the air controls and burn the stove at a high burn setting for  
a longer time to start it burning. The heat generated from the  
fire should be warming your home and establishing the flue  
draft, not evaporating the moisture out of wet, unseasoned  
wood, resulting in wasted heat.  
• Chimney fire  
2. What To Do if Your Stove is Over-Firing  
• Immediately close the door and air controls to reduce  
air supply to the fire.  
• If you suspect a chimney fire, call the fire department  
and evacuate your house.  
• Contact your local chimney professional and have  
your stove and stove pipe inspected for any damage.  
The air control to the right of the stove is called the Start-Up  
Air Control; it is used during the kindling stage of burning.  
It must be closed (pulled out) after the first 5 to 15 minutes.  
Figure 18A.  
• Do not use your stove until the chimney professional  
informs you it is safe to do so.  
Hearth & Home Technologies WILL NOT warranty stoves  
that exhibit evidence of over-firing. Evidence of over-firing  
includes, but is not limited to:  
2nd STAGE  
The next stage of burning, the secondary stage, is the period  
when the wood gives off flammable gases which burn above  
the fuel with bright flames. During this stage of burning it is  
very important that the flames be maintained and not allowed  
to go out. This will ensure the cleanest possible fire. If you  
are adjusting your stove for a low burn rate, you should  
close down the air to the point where you can still maintain  
some flame. If the flames tend to go out, the stove is set  
too low for your burning conditions. The air control slide in  
the center of the stove, beneath the ashcatcher, is the one  
used to adjust the stove for burn rates. This is called the  
Primary Air Slide Control.  
• Warped air tube  
• Deteriorated refractory brick retainers  
• Deteriorated baffle and other interior components  
Page 18  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
FINAL STAGE  
The final stage of burning is the charcoal stage. This occurs  
when the flammable gases have been mostly burned and  
only charcoal remains. This is a naturally clean portion of  
the burn. The coals burn with hot blue flames.  
It is very important to reload your stove while enough lively  
hot coals remain in order to provide the amount of heat  
needed to dry and rekindle the next load of wood. It is best  
to open the air controls for a short while before reloading.  
This livens up the coalbed. Open door slowly so that ash  
or smoke does not exit stove through opening. You should  
also break up any large chunks and distribute the coals so  
that the new wood is laid on hot coals.  
Air quality is important to all of us, and if we choose to use  
wood to heat our homes we should do so responsibly. To  
do this we need to learn to burn our stoves in the cleanest  
way possible. Doing this will allow us to continue using our  
wood stoves for many years to come.  
AIR CONTROLS  
START-UP AIR SYSTEM  
The combustion air enters at the rear of the firebox through  
the rear air tubes. This air supply is controlled by the Start-  
up Air Control. For more air push control in, for less air pull  
control out.  
PRIMARY AIR SYSTEM  
The primary air enters below the ash catcher and is directed  
to the upper front of the firebox, near the top of the glass  
door and to the lower front of firebox. This preheated  
air supplies the necessary fresh oxygen to mix with the  
unburned gases, helping to create secondary, tertiary and  
quaternary combustions. This air is regulated by the Primary  
Air Slide Control. For more primary air slide control left, for  
less air, slide control to the right.  
Primary Air  
Start-Up Air  
Slide Control  
Control  
Figure 19A  
Primary Slide Control  
OPEN - SLIDE LEFT  
CLOSE - SLIDE RIGHT  
Start-Up Control  
OPEN - PUSH IN  
CLOSED - PULL OUT  
Page 19  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
OPERATING INSTRUCTIONS (Cont’d)  
HEAT OUTPUT SETTINGS  
for maximum operating efficiency with the lowest emissions, follow these operating procedures:  
1. Regardless of desired heat output, when loading stove, burn your Quadra-Fire with both air controls  
wide open for 5 to 15 minutes.  
2. Regulate burn rate (heat output) by using the Primary Air Slide Control (center under ashcatcher).  
The Start-Up Air Control (on the right) is used for initial start-up and reloading.  
3. Heat output settings are listed below, following 5 to 15 minutes of burning with controls wide open  
(see #1 above):  
4. Burn dry, well-seasoned wood.  
BTU / Hr  
Below 10,000  
10,000 - 15,000  
15,000 - 40,000  
Maximum Heat  
Start-Up Air Control  
Closed after 5 to 15 minutes  
Closed after 5 to 15 minutes  
Closed after 5 to 15 minutes  
Closed after 5 to 15 minutes  
*Primary Air Slide Control  
Slide to right  
1/8 to 1/2" open (slide to left)  
1/2” to 1-1/8" open (slide to left)  
Fully open (all the way left  
NOTE: These are approximate settings, and will vary  
with type of wood or chimney draft. Due to altitude and  
other environmental circumstances, this operation infor-  
mation is a guideline only. Similar burn rates may be  
obtained using other settings unique to your situation.  
WARNING: Do not operate with Start-Up Air  
Control in the open positionin excess of 15  
minutes! Risk of extreme temperatures! Pro-  
longed operation of this stove with the Start-  
Up Air Control in the open position may cause  
the combustible materials around the stove to  
exceed safe temperature limits.  
OPERATING THE TOP LOADING OPTION  
NOTE: This stove is provided with 3 fiber door handles for  
the door, baffle by-pass handle and the top-load-  
ing griddle slot.  
CAUTION! IF THE DOOR HANDLE IS LEFT ON THE  
STOVE DURING OPERATION, IT MAY OVERHEAT  
AND CAUSE BURNS TO YOUR HAND, EITHER  
REMOVE THE HANDLE DURING OPERATION,  
OR WEAR PROTECTIVE GLOVES. ALSO, USE  
CARE WHEN OPERATING THE DRAFT CONTROL  
KNOBS AS THEY ALSO BECOME HOT DURING  
OPERATION.  
CAUTION! SHIPPING BOLTS MUST BE REMOVED  
PRIOR TO REMOVING GRIDDLE.  
1. Using a 7/16 wrench, remove the 2 shipping bolts under-  
neath the griddle before lifting the griddle off of stove.  
2. Open by-pass door by moving the side handle towards  
rear of stove.  
3. Wait 15 seconds to allow smoke to clear out of firebox.  
4. Slowly open top loading door and load unit with fuel.  
5. Close the top door.  
WARNING! ALWAYS OPERATE THIS APPLI-  
ANCE WITH THE DOOR CLOSEDAND LATCHED  
ExCEPT DURING START-UP AND RE-FUELING  
OR WHEN USING THE FIRESCREEN.  
6. Close the by-pass door (move side handle towards front  
of stove.)  
NOTE: See page 21 for operation considerations with  
a blower installed.  
Page 20  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
OPERATING INSTRUCTIONS (Cont’d)  
caution: before lighting your first fire in the stove: 1) make certain that the baffle is correctly posi-  
tioned. It should be resting against the rear support; 2) Follow instructions on page 22 for cleaning  
plated surfaces, and; 3) Remove all labels from glass.front.  
caution: never use gasoline, gasoline-type lantern fuel, kerosene, charcoal lighter fluid, or similar  
liquids to start or “freshen up” a fire in this heater. Keep all such liquids well away from the heater  
while it is in use.  
BUILDING A FIRE  
There are many ways to build a fire. The basic principle is to light easily-ignitable tinder or paper, which ignites  
the fast burning kindling, which in turn ignites the slow-burning firewood. Here is one method that works well:  
1. Place several wads of crushed paper on the firebox floor. Heating the flue with slightly crumpled newspaper before  
adding kindling keeps smoke to a minimum.  
2. Lay small dry sticks of kindling on top of the paper.  
3. Open Start-Up Air Control and Primary Air Slide Control fully. After 5 to 15 minutes, when the fire is well established, gently  
pull Start-Up Air Control forward until resistance is felt. Do not allow control to "spring back" into the open position.  
4. Make sure that no matches or other combustibles are in the immediate area of the stove. Be sure the room is adequately  
ventilated and the flue unobstructed.  
5. Light the paper in the stove. NEVER light or rekindle stove with kerosene, gasoline, or charcoal lighter fluid; the results can  
be fatal.  
6. Once the kindling is burning quickly, add several full-length logs 3 inches (76mm) or 4 inches (102mm) in diameter. Be careful  
not to smother the fire. Stack the pieces of wood carefully: near enough to keep each other hot, but far enough away from  
each other to allow adequate air flow between them.  
7. When ready to reload the stove, add more logs. Large logs burn slowly, holding a fire longer. Small logs burn fast and hot,  
giving quick heat.  
8. Adjust the Start-Up Air Control and Primary Air Slide Control; the more you close down (slide right) the Primary Air Slide Con-  
trol, the lower and slower the fire will burn. The more you open (slide left) the Primary Air Slide Control, the more heat will be  
produced. The Start-Up Air Control is only used for the first 5 to 15 minutes.  
9. As long as there are hot coals, repeating steps 7 and 8 will maintain a continuous fire throughout the season.  
NOTE: The special high temperature paint that your stove is finished with will cure as your stove heats. You will notice an odor  
and perhaps see some vapor rise from the stove surface; this is normal. We recommend that you open a window until the  
odor dissipates and paint is cured.  
NOTE: Stove should be run full open for 15 minutes a day to keep air passages clean.  
WARNING! DO NOT LEAVE THE FIRE UNATTENDED WHEN THE DOOR IS UNLATCHED OR WHEN USING  
THE FIRESCREEN. UNSTABLE FIREWOOD COULD FALL OUT OF THE FIREBOx CREATING A FIRE  
HAZARD TO YOUR HOME.  
OPACITY  
This helps to determine how cleanly your stove is burning. Opacity is measured in percent; 100% opacity is when an object  
is totally obscured by the smoke column from a chimney, and 0% opacity means that no smoke column can be seen. As you  
become familiar with your stove, you should periodically check the opacity of the smoke column emitted from your chimney.  
This will allow you to know how to burn your stove as nearly smoke-free as possible (aim for a goal of 0% opacity).  
Page 21  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
OPERATING INSTRUCTIONS (Cont’d)  
BURN RATES  
STARTING FIRE: Start fire with both controls fully open (Start-up Air Control pushed all the way IN and Primary Slider Control all  
the way to the LEFT.) Close Start-up Air Control after approximately 5 to 15 minutes,  
HIGH: Leave the Primary Air Slide Control fully open. It is important to do this when reloading the stove. Failure to do this could  
result in excessive emissions (opacity).  
After a wood load has been burning for 5 to 15 minutes on High set the controls as listed below to achieve  
the following burn rates:  
MEDIUM HIGH: Close the Primary Slide Control to 1/2 inch to 1-1/8 inches (13mm to 29mm) open. (Slide left to open, right to close).  
Start-Up Air Control is closed.  
MEDIUM LOW: Close the Primary Slide Control to 1/8 inch to 1/4 inch (3mm to 13mm) open. Start-Up Air Control is closed.  
LOW: Gradually close down the Primary Slider ontrol, making sure to maintain flames in the stove. Start-UpAir Control is closed.  
It is very important to maintain flames in your stove during the first few hours of a low burn to avoid excessive air pollution.  
WOOD SELECTION AND STORAGE  
CAUTION: DO NOT STORE WOOD CLOSER THAN THE REQUIRED CLEARANCE TO COMBUSTIBLES OF THE STOVE  
WITHIN THE SPACE REQUIRED FOR FUELING AND ASH REMOVAL  
Burn only dry seasoned wood! This will not only minimize creosote formation, but also provide the most efficient heat  
output. Even dry wood contains at least 15% moisture by weight and should be burned hot enough to keep the chimney  
hot for as long as it takes to maintain particulate (smoke) burning. It is a waste of energy to burn unseasoned wood of any  
variety. The heat generated from the fire should be warming your home and establishing the flue draft, not evaporating  
the moisture out of wet, unseasoned wood, resulting in wasted heat.  
Dead wood lying on the forest floor should be considered wet, and requires full seasoning time. Standing dead wood can  
be considered to be about two-thirds seasoned. To tell if wood is dry enough to burn, check the ends of the logs. If there  
are cracks radiating in all directions from the center, it is dry. If your wood sizzles in the fire, even though the surface is  
dry, it may not be fully cured. Splitting wood before it is stored reduces drying time. Wood should be stacked so that both  
ends of each piece are exposed to air, since more drying occurs through the cut ends than the sides. This is true even with  
wood that has been split. Store wood under cover, such as in a shed, or covered with a tarp, plastic, tar paper, sheets of  
scrap plywood, etc., as uncovered wood can absorb water from rain or snow, delaying the seasoning process.  
OPTIONAL BLOWER OPERATING INSTRUCTIONS  
1. Initial (cold) start-up: Leave blower off until your stove is hot and a good coalbed is established. The blower may be  
turned on approximately 30 minutes after a good coalbed is established.  
2. High burn setting: The blower may be left on throughout the burn at your desired setting.  
3. Medium burn settings: The blower should be left off until a good burn is established, then turned on at your desired  
setting.  
4. Low burn setting: The blower tends to cool off the stove. Leave blower off until burn is well established. Then turn  
on at your desired rate.  
5. The highest blower speed is obtained by turning the speed control on and then adjusting counterclockwise towards  
"OFF" as far as possible without turning the blower off. For a low blower speed, turn the control knob clockwise as far  
as possible.  
Page 22  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
MAINTENANCE  
CREOSOTE  
TO EMPTY THE ASH PAN AND DISPOSE OF ASHES:  
FORMATION AND NEED FOR REMOVAL: When wood is  
burned slowly it produces tar and other organic vapors which  
combine with expelled moisture to form creosote. The creo-  
sote vapors condense in the relatively cool chimney flue of  
a newly-started or a slow-burning fire. As a result, creosote  
residue accumulates on the flue lining. When ignited, this  
creosote creates an extremely hot fire which may damage the  
chimney or even destroy the house. The chimney connector  
and chimney should be inspected at least once every two  
months during the heating season to determine if a creosote  
or soot build-up has occurred. If creosote has accumulated,  
it should be removed to reduce the risk of a chimney fire.  
1. Allow the stove to cool completely.  
2. CAUTION ! Ash coals can remain extremely hot for  
several days. Protect your hands with gloves when  
removing the ash pan.  
3. DO NOT OPERATE WITHASH PAN DOOR OPEN OR  
WITHASH PAN REMOVED. The hinged door will open  
from the right hand side. Pull ash pan out carefully.  
4. Ashes should be placed in a metal container with a  
tight fitting lid. The closed container of ashes should  
be placed on a noncombustible floor or on the ground,  
well away from all combustible materials, pending final  
disposal. If the ashes are disposed of by burial in soil  
or otherwise locally dispersed, they should be retained  
in the closed container until all cinders have thoroughly  
cooled.  
INSPECTION: The chimney connector and chimney should  
be inspected at least once every two months during the heat-  
ing season to determine if a soot or creosote buildup have  
occurred. Inspect the system at the stove connection and  
at the chimney top. Cooler surfaces tend to build creosote  
deposits quicker, so it is important to check the chimney from  
the top as well as from the bottom.  
5. Replace ash pan and close ash door handle.  
REMOVAL: If soot or creosote have accumulated, it should  
be removed to reduce the risk of a chimney fire. Use a brush  
specifically designed for the type of chimney in use. A chim-  
ney sweep can perform this service. It is also recommended  
that before each heating season the entire system be profes-  
sionally inspected, cleaned, and repaired if necessary.  
Prior to brushing the chimney clean, follow these steps to  
ensure that the accumulation of ash and creosote falls directly  
into the firebox for removal.  
Ash Door  
Handle  
Swings Open  
CHIMNEY CLEANING  
1. Remove all ash from the firebox and extinguish all hot  
embers before disposal. Allow the stove to cool com-  
pletely.  
FIREBRICK  
The firebox of your Quadra-Fire stove is lined with high quality  
firebrick, which has exceptional insulating properties. There  
is no need to use a grate; simply build a fire on the firebox  
floor of your stove. Do not operate stove without firebrick.  
2. Close the door tightly and proceed with sweeping the  
chimney.  
3. Sweep the collected ashes into the ash removal box, and  
empty. Clean out the remaining ashes from firebox.  
4. Open top-loading door and vacuum out.  
ASH REMOVAL & DISPOSAL  
The stove is equipped with an ash removal system. We  
recommend emptying the ash pan at least once a week  
when the stove is in constant operation. The amount of ash  
is dependent on the type of wood being burned.  
DO NOT ALLOW ASHES TO BUILD UP IN THE ASHPAN  
UNTIL THEY REACH THE GRATE. THIS WILL LEAD TO  
PREMATURE DETERIORATION OF THE GRATE AND  
MAKE IT DIFFICULT TO EMPTY THE ASH PAN.  
Page 23  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
MAINTENANCE (CONT'D)  
GLASS CARE  
GLASS REPLACEMENT  
Replace with 5mm ceramic glass only  
NOTE: Remove all labels from glass prior to lighting  
the first fire.  
1. Ensure that the fire is out and the appliance is cool to  
the touch.  
This stove is equipped with ceramic, heat-resistant glass,  
which can only be broken by impact or misuse. Do not slam  
the stove door or impact the glass. When closing the door,  
make sure that logs do not protrude against the glass.  
2. Protect a table or counter top with padding or towels.  
3. Remove door with broken glass from the appliance by  
lifting door up and off of the hinges.  
Inspect the glass regularly for cracks or breaks. If you detect  
a crack or break, extinguish the fire immediately and contact  
your Dealer for replacement.  
4. Lay door face down on a table or counter making sure  
handle and handle attachment knob hang over the  
edge of the table top so door lays flat, on a soft sur-  
face.  
A portion of the combustion air entering the firebox is  
deflected down over the inside of the door glass. This air  
flow “washes” the glass, helping to keep smoke from adher-  
ing to its surface. When operated at a low burn rate, less  
air will be flowing over the glass and the smokey, relatively  
cool condition of a low fire will cause the glass to become  
coated. Operating the stove with the Primary Air Control  
all the way open for 15-20 minutes should remove the built  
up coating. If the deposits on the glass are not very heavy,  
normal glass cleaners work well. Heavier deposits may be  
removed by using a damp cloth dipped in wood ashes or by  
using a commercially available oven cleaner. After using an  
oven cleaner, it is advisable to remove any residue with a  
glass cleaner or soap and water. Oven cleaner left on during  
the next firing can permanently stain the glass and damage  
the finish on plated metal surfaces.  
5. Remove the screws from each glass retainer.  
6. Remove the glass.  
7. Position the glass with edges evenly overlapping the  
opening in the front door.  
8. Replace the glass retainers. Be careful not to cross  
thread the screws.  
9. Tighten each retainer just a few turns until each is  
secured. Then continue to tighten each retainer alter-  
nately, a few turns at a time, until the glass panel is  
tightened snugly.  
10. Replace the door on the appliance.  
Do not clean the glass with abrasive materials that may  
scratch or otherwise damage the glass. Scratches on the  
glass can develop into cracks or breaks. Never attempt to  
clean the glass while a fire is in the unit. The best method  
for maintaining clean glass is to operate the stove efficiently  
by using dry well seasoned wood and burning moderate to  
hot fires.  
CARE AND CLEANING OF PLATED SURFACES  
Clean plated surfaces with vinegar or a glass cleaner before  
lighting your first fire.  
CAUTION: Do not use polishes with abrasives as it will  
scratch the surface.  
WARNING !  
DO NOT OPERATE THE WOODSTOVE IF THE  
DOOR GLASS IS BROKEN OR MISSING. DAN-  
GEROUS OVERFIRING CAN OCCUR WHICH CAN  
DAMAGE THE APPLIANCE OR IGNITE CREO-  
SOTE IN THE CHIMNEY, POSSIBLY CAUSING A  
HOUSE FIRE.  
Page 24  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
MAINTENANCE  
FIREBRICK REPLACEMENT  
Ensure that the firebricks are correctly positioned as referenced by diagram below, and that the  
firebox does not contain any broken brick prior to operating the unit.  
1-1/16"  
1
8-1/4"  
1
4
4
5
5
3
4-1/2"  
3-3/4"  
3
3
9"  
3
3
2
2
Ø
1-1/2"  
5
9"  
Nbr  
1
Brick Size  
9 x 4-1/2 x 1-1/4"  
7 x 1-1/4 x 1-1/4"  
Qty  
2
5"  
2
2
4-1/2"  
3
9 x 4-12/ x 1-1/4" w/cut  
9 x 3-3/4" x 1-1/4"  
4
4
2
5
9 x 4-12/ x 1-14" w/hole  
2
Use Part 832-0550 when ordering individual brick. Please provide brick dimensions or copy this page and  
mark the desired brick and take it to your authorized dealer.  
DOOR & GASKET  
Periodically check the door gasket for proper seal.  
As the gasket compresses or “seats” during use,  
it may become necessary to adjust or tighten the  
door latch either by removing spacer washers,  
Latch Cam  
Door Cross Section  
(example)  
Locknut  
shown below (at least one washer must be left  
Handle  
in place) or, by replacing the gasket material as  
wear or damage to the gasket material can cause  
air leakage into the firebox resulting in overfiring  
and loss of efficiency. A replacement gasket is  
available from your dealer.  
Teflon Washer  
DO NOT REMOVE  
Spacing Washers  
Square Key  
Page 25  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Service & Maintenance Log  
Date of Service  
Performed By  
Description of Service  
Page 26  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Exploded Views  
3
4
6
7
5
8
2
9
10  
11  
12  
1
13  
14  
17  
16  
15  
20  
19  
18  
* Part number list on following page.  
Page 27  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Service Parts  
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on the Quadra-Fire web site  
at www.quadrafire.com. When ordering, supply serial and model numbers to ensure correct part.  
Item  
#
Part Description  
Alphabetical Order  
SKU  
Andiron Brackets, Pair  
Andirons with Brackets  
Ash Removal System Handle Assembly  
Ash Box Hinge  
832-3610  
844-8980  
472-5060  
434-0310  
29125  
Ash Lip Must specify color.  
Ash Pan  
434-0330  
434-0300  
834-4100  
SRV434-5010  
434-0370  
434-0080  
834-4040  
434-0110  
434-0100  
831-1701  
821-0110  
434-7060  
812-4900  
Ash Removal Door  
Ash Removal Grate  
Baffle Assembly  
11  
9
Baffle Back Plate  
Baffle Control Cam  
Baffle Repair Kit  
Baffle, Cast  
Baffle, Lever  
Blower Assembly  
Blower Cord with Speed Control  
Blower Cover Plate, Rear Vent  
Blower Only, Service  
Brick Retainer  
434-0460  
834-3860  
SRV434-0620  
832-0550  
32084  
1
Brick Set  
Bricks with Hole (2)  
Brick, Single, Uncut, Pumice  
Cam Latch  
20  
Component Pack, Matte Black  
MBK: 434-5160  
PMH: 434-5220  
(Includes Owner’s Manual; Griddle Handle; Fiber Handle; Warranty Card; Touch-up Paint)  
Control System Control Rod  
Door Hinge, Left  
31940  
434-0470  
Door Hinge, Right  
434-0480  
13  
13  
14  
14  
Door, Left, Matte Black  
844-9640MBK  
844-9650POR  
844-9680MBK  
844-9690POR  
434-0650  
Door, Left, Porcelain (Must specify color).  
Door, Right, Matte Black  
Door, Right, Porcelain (Must specify color).  
Fiberboard, Baffle  
Fiberboard, Rear  
434-0660  
4
3
5
Flue Shield, Bottom  
434-0680  
Flue Shield, Top  
434-0670  
Flue Transition Assembly  
7006-019  
Gasket, Glass Rope, 1/4”, 10 ft.  
Gasket, Rope, Door  
834-1460  
834-4170  
16  
Glass Assembly  
434-5230  
Page 28  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Service Parts  
IMPORTANT: THIS IS DATED INFORMATION. The most current information is located on the Quadra-Fire web site  
at www.quadrafire.com. When ordering, supply serial and model numbers to ensure correct part.  
Item  
#
Part Description  
Alphabetical Order  
SKU  
17  
6
Glass Retainer Clip  
32178  
Griddle  
834-4190  
434-0440  
834-4000  
834-4080  
7000-114  
SRV433-1380  
834-3850GD  
834-3850NL  
433-1590  
Qty 1: 72171  
834-3790  
32284  
Griddle Hinge  
7
Griddle Tool  
Handle, Baffle, Gold  
Handle, Baffle, Nickel  
Handle, Fiber  
18  
Handle, Replacement Kit, Gold  
Handle, Replacement Kit, Nickel  
Hinge Pin, Nickel, Button Head Rivet  
Hinge Pin, Gold, Button Head Rivet  
Horizontal Flue Kit  
15  
15  
Knob, Air Control  
19  
Latch Cam, Key  
430-1151  
26404MBK  
26404PMH  
832-0661  
832-3360  
434-0500  
842-0370  
434-5150  
434-0050  
832-3380  
434-0640  
Leg, Matte Black  
Leg, Porcelain, Mahogany  
Manifold Clip/Screws (4)  
Manifold Tube Set  
10  
2
Rear Shield  
Speed Control  
Tool Holder Assembly  
Top Plate, Matte Black  
Top Plate, Porcelain (Must specify color).  
Wear Plate, Stainless Steel  
8
8
12  
Accessories  
Part No.  
831-1701  
Blower  
Brackets with Mitten Rod, Gold, WSB2G-2  
Brackets with Mitten Rod,, Black, WSB2-2  
Firescreen, (USA installations only)  
Outside Air Kit  
844-7980  
844-7970  
834-3610  
831-1780  
834-3531  
834-4110  
Warming Shelves, Matte Black, WS3-2 MBK  
Warming shelves, Porcelain Mahogany, WS3-2 PMH  
Page 29  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Warranty Policy  
Hearth & Home Technologies LIMITED WARRANTY  
Hearth & Home Technologies (“HHT”) and its respective brands extends the following warranty for HHT gas, wood,  
pellet and electric appliances purchased from an authorized HHT dealer and installed in the United States of America or  
Canada. Warranty starts with date of purchase by the original owner (End User) except as noted for replacement parts.  
HHT Manufactured Appliances and Venting  
Warranty Period  
Parts Labor  
EPA  
Components Covered  
Gas  
X
Wood  
X
Pellet  
X
Electric  
X
Venting  
X
Wood  
All Parts and Material Except  
as covered by Conditions,  
Exclusion, and Limitations  
listed  
1 Year  
X
Igniters, Electronic Compo-  
nents, and Glass  
Blowers  
X
X
X
X
2 years  
3 years  
X
X
X
Molded Refractory Panels  
X
X
Firepots  
5 years  
3 years  
3 years  
X
X
Castings & Baffles  
Firebox, HHT Chimney, Termi-  
7 years  
X
X
X
X
nation & Heat Exchanger  
10  
1 year  
1 year  
X
years  
Burners, Logs & Refractory  
Limited  
Lifetime  
X
X
Firebox & Heat Exchanger  
All Replacement Parts  
90 Days  
X
X
X
See Conditions, Exclusions, and limitations.  
9-01-08  
CONDITIONS, ExCLUSIONS & LIMITATION OF LIABILITY  
.
This warranty applies to the original owner and is transferable up to two years from date of purchase to the new  
homeowner, provided the purchase was made through an authorized dealer or distributor of HHT, and the appliance  
remains in its original place of installation.  
.
.
.
The maximum amount recoverable under this warranty is limited to the purchase price of the product.  
In no event shall HHT be liable for any incidental or consequential damages caused by defects in the product.  
Adjustments, regular maintenance, cleaning and temporary repairs, or the failure to duplicate the problem in the home  
is not covered under this warranty.  
.
This limited warranty does not extend to or include surface finish on the appliance or terminations, door gasketing,  
glass gasketing, glass discoloration, firebrick, pellet logs, kaowool or other ceramic insulating materials. Rust and/or  
corrosion on any of the metal surfaces, cast iron components, baffles, firepots, doors, or firebox area are not covered  
by this warranty.  
4021-645A 09-01-08  
Page 30  
September 1, 2008  
250-5763C  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
Isle Royale Wood Stove  
Hearth & Home Technologies LIMITED WARRANTY (Cont'd)  
.
.
Noise resulting from minor expansion, contraction, or movement of certain parts is normal and complaints related to  
this noise are not covered by this warranty.  
HHT’s obligation under this warranty does not extend to damages resulting from: (1) installation, operation or main-  
tenance of the appliance not in accordance with the installation instructions; operating instructions and the listing  
agent identification label furnished with the appliance; (2) installation which does not comply with local building codes;  
(3) shipping, improper handling, improper operation, abuse, misuse, accident or unworkmanlike repairs; (4) environ-  
mental conditions, inadequate ventilation or drafting caused by tight sealing construction of the structure or handling  
devices such as exhaust fans or forced air furnaces or other such causes; (5) use of fuels other than those specified  
in the operating instructions; (6) installation or use of components not supplied with the appliance or any other com-  
ponents not expressly authorized and approved by HHT; and/or (7) modification of the appliance not expressly autho-  
rized and approved by HHT in writing.  
.
.
This warranty does not apply to non-HHT venting components, hearth components or other accessories used in con-  
junction with the installation of this product.  
This warranty is void if the appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluo-  
rine, or other damaging chemicals the appliance is subject to prolonged periods of dampness or condensation, or  
there is any damage to the appliance or other components due to water or weather damage which is the result of, but  
not limited to, improper chimney or venting installation.  
.
HHT’s liability under this warranty is limited to the replacement and repair of defective components or workmanship  
during the applicable period. HHT may fully discharge all of its obligations under such warranties by repairing the  
defective component(s) at HHT’s discretion. Shipping costs are not covered under this warranty.  
.
.
Some states do not allow exclusions or limitation of incidental or consequential damages, so those limitations may not  
apply to you. This warranty gives you specific rights; you may also have other rights, which vary from state to state.  
EXCEPT TO THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE  
WARRANTY SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF  
THE WARRANTY SPECIFIED ABOVE.  
This Limited Warranty is effective on all HHT appliances sold after September 01, 2008 and supersedes any and all war-  
ranties currently in existence.  
If warranty service is needed, you should contact your installing dealer. If the installing dealer is unable to provide neces-  
sary parts or components, contact the nearest authorized HHT dealer or supplier.  
4021-645A 09-01-08  
Page 31  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  
R
CONTACT INFORMATION:  
Hearth & Home Technologies  
1445 north highway  
colville, wa 99114  
Division of HNI INDUSTRIES  
www.quadrafire.com  
Please contact your Quadra-Fire dealer with any questions or concerns.  
For the number of your nearest Quadra-Fire dealer,  
call 1-800-926-4356  
CAUTION  
• Do NOT discard this manual.  
• Important operating and maintenance  
instructions included.  
• Read, understand and follow these instruci-  
tons for safe installation and operation.  
• Leave this manual with party responsible for  
use and operation.  
Your Records for Model:  
Isle Royale Wood Stove  
WHERE PURCHASED:  
SERIAL NUMBER:  
DATE PURCHASED:  
DATE INSTALLED:  
__________________  
__________________  
__________________  
_______________________________________  
_______________________________________  
_______________________________________  
TELEPHONE: __________________  
This product may be covered by one or more of the following patents: (United States) 4593510, 4686807, 4766876,  
4793322, 4811534, 5000162, 5016609, 5076254, 5113843, 5191877, 5218953, 5263471, 5328356, 5341794, 5347983,  
5429495, 5452708, 5542407, 5601073, 5613487, 5647340, 5688568, 5762062, 5775408, 5890485, 5931661, 5941237,  
5947112, 5996575, 6006743, 6019099, 6048195, 6053165, 6145502, 6170481, 6237588, 6296474, 6374822, 6413079,  
6439226, 6484712, 6543698, 6550687, 6601579, 6672860, 6688302B2, 6715724B2, 6729551, 6736133, 6748940,  
6748942, D320652, D445174, D462436; (Canada)1297749, 2195264, 2225408; or other U.S. and foreign patents  
pending.  
Page 32  
250-5763C  
September 1, 2008  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Baby Accessories PD247333A User Manual
Hasbro Games 59757 User Manual
Honeywell Wireless Office Headset 9590 User Manual
Hoshizaki Ice Maker DM 180A User Manual
HP Hewlett Packard Air Cleaner 20 Feb User Manual
HP Hewlett Packard Hunting Equipment 54112 User Manual
HP Hewlett Packard Server 8200zl 5400zl 3500yl Series User Manual
Husqvarna Snow Blower ST 276EP User Manual
Husqvarna Spreader 70 PP User Manual
hussman Network Router P N 374511B User Manual