Heart Home Collectables Blower GFK 210 User Manual

GFK-210 Blower System  
- Installation and Operating Instructions -  
This blower is carefully engineered and must be installed  
1.0 INTRODUCTION  
only as specied. If you modify it or any of its components,  
you may cause a re hazard and will void the WARRANTY.  
In addition, such action may void the coverage provided  
by the owner's home insurance.  
The GFK-210 Blower System has been designed to circu-  
late room air through the replace to enhance heat output.  
The GFK-210 blower system operates on 120 VAC, 60 Hz  
power. This is available through a receptacle in the factory  
installed power cord assembly. The power cord is located  
in the controls compartment of the replace.  
CAUTION: All wiring should be done by a qualied electri-  
cian and shall be in compliance with local codes and with  
the National Electric Code ANSI/NFPA NO. 70-current (in  
the United States), or with the current CSAC22.1 Canadian  
Electric Code (in Canada).  
Avariable speed control is provided with the blower system  
to provide quiet forced air ow at the desired speeds. A  
temperature sensor switch, which automatically turns the  
blower ON/OFF, is also provided with this kit.  
CAUTION! DO NOT connect 110-120 VAC wiring to the  
gas control valve of the replace.  
NOTICE: The variable speed control and temperature  
sensor switch are not used with some remote control  
systems.  
WARNING! Risk of Shock! Turn electrical power off at  
the circuit breaker before beginning this installation.  
4.0 INSTALLING THE BLOWER (Metal Inserts)  
2.0 CHECK CONTENTS OF SHIPPING CARTON  
1. Remove factory-installed blower brackets by removing  
four screws. Brackets are only used for the FireBrick  
inserts. See Figure 2.  
Compare CONTENTS OF CARTON in Figure 1 with the  
actual parts received. If any parts are missing or damaged,  
contact your dealer before starting installation. Do not install  
a damaged blower kit.  
2. Remove appliance from wall.  
3. Remove access panel by removing four screws. See  
Figure 3.  
4. Screw blowers to access panel on rear of insert with  
four screws. See Figure 4.  
5. Plug the blower cord into the blower receptacle. Con-  
nect the white, black, and green spade connectors  
from blower cord harness to each blower. See Figure  
1 and Figure 6.  
WING  
NUT  
060-872  
6. Bundle and zip tie any wires to keep them from contact-  
ing the fan blades. See Figure 6, Detail A.  
BLOWER CORD  
2206-068  
7. Reinstall access panel.  
TEMPERATURE  
SENSOR  
SWITCH  
NOTE: Install the blower using the access panel located on  
the back side of the appliance.  
CONTROL  
KNOB  
046-018A  
100-512  
CONTROL  
NUT  
060-814  
VARIABLE SPEED CONTROL  
2206-800  
Figure 1  
3.0 INSTALLATION PRECAUTIONS  
The GFK-210 Blower Kit is tested and safe when installed in  
accordance with this installation manual. It is your responsi-  
bility to read all instructions before starting installation and to  
follow these instructions carefully during installation to assure  
maximum benet from, and safe operation of, the blower.  
Figure 2 Remove Blower Brackets  
Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
1
5.0 INSTALLING THE VARIABLE SPEED  
6.0 RECOMMENDED OPERATING PROCE-  
DURES WHEN VARIABLE SPEED CONTROLAND  
TEMPERATURE SENSOR SWITCH ARE USED  
Ignite the re in the replace with the variable speed control  
switch in an "ON" position. The fan will automatically turn  
on when the temperature sensor switch closes at approxi-  
mately 110O F. Heated air will be delivered at the outlet  
grille. The fan will continue to operate after the replace  
is turned OFF until the temperature sensor switch opens.  
CONTROL AND TEMPERATURE SENSOR SWITCH  
If using a remote control system that utilizes a blower  
(fan) control, disregard steps 1-3 and follow remote con-  
trol installation instructions.  
NOTICE! The sensor switch and rheostat are not used  
if the blower is controlled with the RC300 remote control.  
1. Remove the knob and locknut from the variable speed  
control. Slide the variable speed control behind the  
control panel. With the stem sticking out of the pre-  
punched hole, attach the locknut tightly and reattach  
the knob on the stem. See Figure 4. Turn the speed  
control switch to the "ON" position.  
NOTICE! During operation, ensure that all wiring is  
kept away from the blower wheel (fan blades).  
Various conditions (such as replace model, type of re-  
place installation, outside air temperature vs. inside air  
temperature) can contribute to the length of the time the  
blower remains on after the replace is turned OFF. The  
blower can be turned off manually with the speed control  
switch.  
2. Slide the temperature sensor switch onto the blower  
stud located on the bottom of the combustion box. See  
Figure 3. Secure the temperature sensor switch with  
the wing nut provided.  
WARNING! Risk of Injury! DO NOT contact the blower  
wheel (fan blades) during operation.  
NOTICE: The blower stud is located on the bottom of the  
combustion box. See Figure 5.  
NOTICE:The temperature sensor switch must be installed  
so that the sensor switch is facing the combustion box  
surface. See Detail A of Figure 5.  
7.0 MAINTENANCE  
Periodically check the replace and remove any dust, dirt  
or obstructions.  
3. Connect the variable speed control and the temperature  
sensor switch to the power cord. See Figure 6.  
8.0 REPLACEMENT PARTS AND CUSTOMER  
SERVICE  
4. Gather the loose wires underneath the appliance and  
use the zip ties to restrain them and keep them away  
from the blower wheel (fan blades). See Figure 6,  
Detail A.  
Replacement parts and service may be obtained through  
your dealer.  
Hardware Bag: SRV107-570A  
5. Turn the 110-120 VAC service "ON" at the circuit  
breaker.  
VARIABLE  
SPEED  
CONTROL  
TEMPERATURE  
SENSOR  
SWITCH  
BLOWER  
STUD  
DETAIL A  
COMBUSTION BOX SURFACE  
BLOWER STUD  
TEMPERATURE SENSOR SWITCH  
Figure 5  
Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
PLUG  
120V EXISTING  
OUTLET  
BLOWER  
NOTE: IF ANY OF THE ORIGINAL  
WIRE AS SUPPLIED WITH THE  
APPLIANCE MUST BE REPLACED,  
IT MUST BE REPLACED WITH  
TYPE 1050 C RATED WIRE.  
DETAIL A  
POWER CORD  
TEMPERATURE  
SENSOR  
BLOWER  
CORD  
SWITCH  
CONTROL  
PANEL  
DETAIL A  
TO VALVE BRACKET  
(GROUND)  
GRN  
VARIABLE  
SPEED  
CONTROL  
ORG  
TO VALVE  
(RHEOSTAT)  
BRN  
BLACK  
RED  
ZIP TIES  
PLUG INTO 120V  
EXISTING OUTLET  
POWER  
CORD  
DC REGULATOR  
RECEPTACLE  
VARIABLE SPEED  
CONTROL  
BLK  
BLK  
BLK  
BLK  
WHT  
GRN  
BLK  
BLK  
GRN  
BLOWER  
CORD  
BLK  
BLOWERS  
BLOWER  
RECEPTACLE  
TEMPERATURE  
SENSOR SWITCH  
BLK  
GRN  
BLK  
GRN  
BLK  
WHT  
Figure 6. Fan Wiring Diagram - Metal Insert Without RC200/RC300  
4
Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
2. Plug two cord assembly spade connectors together.  
3. Unplug fan cord assembly from standard cord assembly.  
9.0 Fan Wiring with Remote  
This appliance may be used with an RC200 or RC300  
remote control. See Figure 7.  
4. Install fuse wire assembly in series between the black  
lead wires of the fan cord and black lead wire on each  
blower. See Figure 7.  
1. Remove cord assembly spades from rheostat and  
sensor switch.  
5. Plug fan cord assembly into AUX300 module.  
NOTICE: Fan speed and operation are controlled by the  
remote control. The sensor switch and rheostat are no  
longer needed.  
6. Plug AUX300 module into the standard cord assembly.  
NOTE: IF ANY OF THE ORIGINAL  
WIRE AS SUPPLIED WITH THE  
APPLIANCE MUST BE REPLACED,  
IT MUST BE REPLACED WITH TYPE  
PLUG  
1050 C RATED WIRE.  
120V EXISTING  
BLOWER  
OUTLET  
STEP 5  
NOTE: USE ZIPTIES TO RESTRAIN  
THE LOOSE WIRES UNDERNEATH  
THE APPLIANCE AND KEEP THEM  
AWAY FROM THE BLOWER WHEEL  
(FAN BLADES).  
STEPS  
1 & 2  
STEPS  
3 & 5  
SENSOR SWITCH  
WHT (2)  
GRN (2)  
BLK (2)  
BLK (2)  
GRN (2)  
BLK (2)  
SPEED CONTROL  
(RHEOSTAT)  
NOTE: SENSOR SWITCH AND  
RHEOSTATSPEED CONTROLMUST  
BE REMOVED FROM CIRCUIT IF  
SYSTEM IS CONTROLLED WITH  
RC200/300 REMOTE.  
PLUG INTO 120V  
EXISTING OUTLET  
BLK  
GRN  
WHT  
GRN  
BLK  
DC REGULATOR  
RECEPTICLE  
BLK  
BLOWERS  
AUX 300 MODULE  
FAN  
FUSE WIRE  
ASSEMBLY  
TO CONTROL  
MODULE  
FUSE WIRE  
ASSEMBLY  
BLK  
BLK  
BLK  
BLK  
GRN  
WHT  
GRN  
BLK  
BLOWER  
RECEPTICLE  
Figure 7. Fan Wiring Diagram - Metal Insert with RC200/RC300 Remote  
Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
10.0 INSTALLING THE BLOWER (FireBrick Inserts)  
1. Remove appliance from wall.  
2. Disconnect power by shutting off circuit breaker or  
unplugging appliance power cord from its receptacle.  
3. Remove access panel from lower rear of the replace  
insert. See Figure 8.  
4. Attach blower to base with two screws. See Figure  
9. Connect white and green wires from blower wire  
assembly to each blower. See Figure 9. Connect the  
fuse wire assembly in series between black wires of  
blower wire assembly and each blower. See Figure  
10.  
BLOWER  
ACCESS PANEL  
5. Insert plug from blower cable assembly into AUX300  
receptacle. See Figure 10.  
POWER CORD  
6. Bundle and zip tie loose wires to keep them from con-  
tacting blower impeller blades  
Figure 8. Remove Access Panel  
7. Position the right and left blower assembly into the rear  
opening. Take care to ensure that blower housing or its  
motor is clear of any adjacent metal. This will ensure  
that no undue noise occurs during blower operation.  
8. Reinstall access panel.  
9. Reconnect power to the insert and install into wall.  
Figure 9. Attach Blower to Base  
6
Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Note: if any of the original wire as  
supplied with the appliance must  
be replaced, it must be replaced  
with type 105 °C rated wire.  
PLUG TO  
EXISTING  
OUTLET  
BLOWERS  
Note: use zip ties to restrain  
the loose wires underneath the  
appliance and keep them away  
from the blower wheel (fan blades).  
PLUG INTO 120V  
EXISTING OUTLET  
BROWN  
RED  
BLACK  
DC REGULATOR  
RECEPTACLE  
GROUND (TO VALVE BRACKET)  
GREEN (TO VALVE)  
ORANGE (TO VALVE)  
BLK  
WHT  
GRN  
BLK  
BLK  
GRN  
BLK  
BLOWERS  
BLOWER  
RECEPTACLE  
FUSE WIRE  
ASSEMBLY  
BLK  
FUSE WIRE  
ASSEMBLY  
BLK  
GRN  
WHT  
BLK  
GRN  
BLK  
Figure 10. Fan Wiring Diagram - FireBrick Inserts  
Please contact your Hearth & Home Technologies dealer  
with any questions or concerns.  
Hearth & Home Technologies Inc.  
7571 215th Street West, Lakeville, MN 55044  
For the location of your nearest  
www.reside.com  
Hearth & Home Technologies dealer,  
please visit www.reside.com.  
Hearth & Home Technologies • GFK-210 Blower System Instructions 2206-938 Rev. H • 7/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7

Haier Dehumidifier DE45EJ User Manual
Haier Washer HW70 B14266 User Manual
Haier Washer XPB50 ASP User Manual
Haier Washer XQBM30 22 User Manual
Havis Shields Laptop C 3090 User Manual
Healthrider Treadmill HRTL08010 User Manual
Honeywell Burner M9481 User Manual
Honeywell Frozen Dessert Maker 5080 User Manual
Huffy Bicycle M0012 User Manual
Hyundai Car Satellite Radio System CD MP3 Receiver User Manual