Hasselblad Power Supply Flextight 343 User Manual

User's Guide  
Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Table of Contents  
3
Table of Contents  
Hardware Reference - Flextight 343  
Warnings and Restrictions  
System Requirements  
5
6
6
7
8
9
Front Panel  
Back Panel & Connectors  
Cut-Away View  
Setting up the Scanner  
10  
10  
10  
11  
Environmental Requirements  
Electrical Requirements  
Installation Procedure, FireWire Interface  
Operating the Scanner  
13  
Resolutions  
14  
14  
True Optical Resolutions  
The Light Tube  
Orientation of the Light Tube  
Replacing the Light Tube  
16  
16  
17  
Cleaning the External Surface of the Scanner  
Disposal  
19  
19  
20  
21  
22  
Technical Specifications  
FCC Notice  
CE - Declaration of Conformity  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
5
Hardware Reference - Flextight  
343  
This manual provides important information about using your Flextight  
343 scanner.  
Topics include:  
Important warnings and restrictions  
System requirements  
Diagrams of the front panel, rear panel, and internal structure of the  
Flextight 343 scanner  
Installation instructions  
Environmental requirements  
Electrical requirements  
Operating instructions  
Maintenance advice  
Disposal instructions  
Technical specifications  
Declarations of FCC and CE regulation conformity  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
6
Warnings and Restrictions  
Warnings and Restrictions  
Read all of the included documentation before attempting to install  
and use the scanner.  
Do not touch the originals and/or the original holder while scanning.  
Do not start scanning or previewing until an original holder with an  
original has been mounted.  
The original holder is only to be mounted or removed when the drum  
is in the load position.  
When you turn on the scanner, the drum will roll to the load position,  
if it is not there already. Do not touch the scanner while the drum is  
rotating.  
Do not place your fingers or any other object into the scanner while it  
is connected to power.  
Before servicing or opening the scanner, the power supply must be  
disconnected from the mains (unplugged). It is not sufficient simply to  
press the on/off button.  
Install the scanner in a location where children can not get to it. It  
contains small openings and moving parts that can cause injury.  
System Requirements  
Below are the basic hardware requirements for the PC or Macintosh  
system to which the scanner is to be connected.  
For information about the processor, operating system, RAM and  
harddisk requirements please refer to the “Software Reference” manual,  
that comes with the FlexColor software.  
Screen resolution of 800 x 600 pixels with true colors (24-bits).  
Mouse or other pointing device.  
FireWire interface  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
7
Front Panel  
Front Panel  
C
D
A
B
E
Figure 1: Front panel features of Flextight 343  
A
Feed Table: place original holders here for scanning. The table can  
be folded up to keep dust from entering the scanner and to keep it  
out of the way.  
B
C
Light Area: for viewing originals. The grid helps you to align the  
originals.  
Indicator light: The indicator can light up in 3 different colors  
indicating the following:  
Green (Power/Ready) - remains lit when ready to scan. Flashes  
when first installed to indicate that firmware must be loaded (it will  
be loaded automatically when you run FlexColor).  
Yellow (Motor Drive) - when drum is repositioning.  
Red (Scanning) - when scanning. Do not touch the scanner while  
the indicator is red. If the light is flashing when not scanning, then  
an error has occurred - please contact your Flextight dealer for  
assistance.  
D
E
Power Switch: press to turn the unit on/off.  
Original Holder Clasp: all original holders slide into a slot here and  
are held in place by magnets.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
8
Back Panel & Connectors  
Back Panel & Connectors  
A
B
FireWire  
346  
Figure 2: Back panel features of Flextight 343  
A
B
Power Cable Socket: plug the power cable into this socket.  
FireWire Interface Sockets: plug a FireWire cable (max. 6 m) here  
and connect it to your computer. You can use the second plug to  
connect another device (hard disk, printer etc.) to the FireWire chain.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
9
Cut-Away View  
Cut-Away View  
A
B
C
D
FLEXTIGHT  
ORIGINAL  
HOLDER  
E
Figure 3: Cut-away view of Flextight 343  
A
B
C
CCD Plate: this platform contains the light sensor.  
Optics: focuses the image of the original on the CCD.  
Drum: rotates the original into the scanner and steps it past the CCD  
line of focus.  
D
E
Light Tube: illuminates the transparent originals. The tube also  
provides the light for the feed table.  
Original Holder: an original holder is shown mounted and with the  
magnetic top layer held open.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
10  
Setting up the Scanner  
Setting up the Scanner  
Environmental Requirements  
Set up the scanner in a location that fulfils the following requirements:  
Keep the scanner away from sources of heat, such as direct sunlight or  
a radiator. Warm temperatures will degrade the quality of your scans -  
for best results, work in a cool environment.  
The scanner must be operated away from sources of strong  
electromagnetic interference. Although the scanner complies with all  
regulations governing electromagnetic immunity and Hasselblad has  
taken every reasonable step to make the unit immune to  
electromagnetic interference, it is still a precision electronic device so  
strong radio waves can interfere with your scans.  
The surface on which the scanner is placed must be stable and free  
from vibrations. If the scanner is shaken or moved while scanning,  
your results may be affected.  
If the scanner has been in a colder environment (e.g. outside or in  
storage) just before you set it up in a warmer room, then wait about  
two hours before using it - otherwise, condensation may form, which  
will prevent the scanner from operating correctly.  
Avoid using the scanner in areas where there is a high level of dust.  
To prevent dust from getting into the scanner, always close the feed  
table when the scanner is not in use.  
Electrical Requirements  
The Flextight 343 power supply requires a mains voltage of between 100  
and 240 V AC at a frequency of 50 to 60 Hz. This is within the normal  
wall-socket power standards of most countries. Do not attempt to use  
Flextight 343 with any power source outside the specified range.  
The scanner and all devices attached to the scanner (computer, monitor,  
and FireWire devices, etc.) must be grounded (i.e. use a three-point  
electrical connection).  
Note that the power supply may emit a low hissing sound when  
plugged in but not connected to the scanner. This is normal and will not  
damage the power supply or scanner.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
11  
Setting up the Scanner  
Installation Procedure, FireWire Interface  
1. Place the scanner on a table near your computer with the front  
facing away from you. Make sure that the location you choose meets  
all environmental - and electrical requirements as described on page  
10.  
2. When using a FireWire interface connection, it is not necessary to  
switch of your computer and other connected units. Connect a  
FireWire cable from one of the FireWire connectors on your scanner  
(see “Back Panel & Connectors” on page 8) to either the computer's  
FireWire connector or to a free FireWire connector on any other  
FireWire device already connected to your computer.  
3. Connect the round connector from your power supply to the round  
power supply socket on the back of the scanner.  
4. IMPORTANT: Make sure that the wall socket you are planning to  
use meets the electrical requirements outlined earlier.  
Plug the Flextight 343 power supply into a wall socket. Note that the  
power supply may emit a low buzzing sound when plugged in. This  
is normal and will not damage the power supply or scanner.  
5. Turn the scanner around so that the front is facing you.  
6. Your system is assembled. Turn on your computer and install the  
FlexColor image scanning software.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
12  
Operating the Scanner  
F
G
H
A
B
FLEXTIGHT  
ORIGINAL  
HOLDER  
PA  
TENT  
J
PENDING  
C
D
E
Figure 4: Operating the Flextight 343 scanner  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
13  
Operating the Scanner  
Operating the Scanner  
(See Figure 4 opposite).  
1. It is assumed that the scanner and FlexColor software have been  
properly installed.  
2. Pull the feed table (B) down to scan position.  
3. Press the power button (G) on the front of the scanner to switch it  
on. The indicator light (F) button will start flashing green, indicating  
that no firmware has been downloaded yet. It will be downloaded  
automatically later when you first run the FlexColor program.  
4. Turn on your computer and launch the FlexColor program. The  
indicator light (F) will stop flashing indicating that firmware has  
been downloaded to the scanner.  
5. Select the original holder (D) that matches your original.  
6. Place the original holder with the slotted tab facing into the scanner.  
The flexible magnetic layer (C) must face upwards and the holder  
must fit between the guides (A) on both sides of the feed table.  
7. Slide the holder gently into the original holder clasp (H) at the  
scanner entrance. It will slip about ½ cm (1/4 inch) into it. Do not  
press too hard. It slips in very easily and is held in place by a pair of  
magnets. To remove the holder, simply pull it gently backwards.  
8. Lift the magnetic layer (C) of the original holder and place your  
original (E) with the emulsion side up. The original must completely  
fill the hole with no edges showing and with a minimum overlap of  
2mm along each edge. Also, no edges of the original must extend  
past the outer edges of the holder. Use the grid in the light area (J) of  
the feed table (B) to help line up the image.  
9. Lay the top layer of the holder down flat over the original. The top  
layer (C) is magnetic, which will hold the original in place.  
10. Go to your computer and follow the directions given in the  
FlexColor software manual to take a preview, make settings, and  
take the final scan.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
14  
Resolutions  
Resolutions  
True Optical Resolutions  
The table below shows the true optical resolutions (in ppi) available with  
each of the original holders. When scanning at one of the resolution  
settings listed, one pixel in the scanner’s image sensor corresponds  
exactly to one pixel in the final image. If you use a resolution setting  
other than those listed, then interpolation (resizing) must be applied.  
Resolutions (PPI)  
Original  
Max.  
3200  
3200  
3200  
3200  
3200  
½
1/3  
1/4  
800  
800  
800  
800  
800  
1/6  
533  
533  
533  
533  
533  
1/12  
24 x 36  
36 x 24  
60 x 60  
60 x 90  
60 x 120  
1600  
1600  
1600  
1600  
1600  
1067  
1067  
1067  
1067  
1067  
267  
267  
267  
267  
267  
Table 1: True Optical Resolutions  
To avoid activating the resizer, select a zoom setting that gives one of the  
results listed in Table 1. When resizing is applied, the scans take longer  
and image quality is slightly reduced. The impact on the image quality  
will vary according to the amount of interpolation required and the  
contents of your original.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
15  
Resolutions  
Example: For an output resolution of 300 ppi, take the true resolution  
shown in Table 1, divide by 300 and multiply by 100%. Enter the result  
in the Zoom field in the main FlexColor window.  
Zoom Setting  
Original  
Max.  
½
1/3  
1/4  
1/6  
Res.  
1/12  
Res.  
Resolution  
Res.  
Res.  
Res.  
3200  
x100%  
300  
24 x 36  
533% 356% 266% 178%  
89%  
= 1067%  
1067%  
1067%  
1067%  
1067%  
36 x 24  
60 x 60  
60 x 90  
60 x 120  
533% 356% 266% 178%  
533% 356% 266% 178%  
533% 356% 266% 178%  
533% 356% 266% 178%  
89%  
89%  
89%  
89%  
Table 2: Zoom settings for true optical resolution at 300 ppi output  
Note that when the Zoom field is set to an appropriate value for the  
selected original size (as shown in the table above), then the PPI pop-up  
menu shows an underline beneath each setting that will result in a scan  
taken with a true resolution (no interpolation).  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
16  
The Light Tube  
The Light Tube  
Orientation of the Light Tube  
Flextight 343 contains a light tube that illuminates your originals while  
scanning. The light tube is fitted with a reflective sleeve, which must be  
aligned correctly inside the scanner. The sleeve helps direct the light to  
achieve maximum illumination of the original. When you replace the  
light tube, you must make sure the sleeve is aligned correctly.  
Sometimes the sleeve is glued into place when the scanner is first  
shipped from the factory, but when you replace a light tube, the sleeve  
will not be glued; it will be tight so that it can not slip freely, but you will  
be able to rotate it manually if you try. The correct orientation of the  
sleeve is shown in Figure 5.  
Illuminate original/CCD  
Transmission Lamp  
Illuminate  
Feed table  
light area  
Align the sleeve with the  
pins as shown. Note that  
the long top slot should line  
up between the two pins  
Figure 5: Light tube sleeve alignment as seen from the left side of the scanner  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
17  
The Light Tube  
Replacing the Light Tube  
If your scans are suddenly coming out black (or all white if you are  
scanning negatives), then the light tube may be defective or misaligned.  
Follow procedure below to replace a tube:  
1. Get the appropriate replacement light tube (ask your Flextight dealer  
or see specification in “Technical Specifications” on page 20).  
2. Turn off and unplug the scanner from the primary power supply.  
3. IMPORTANT: Let the light tube cool down for app. 10 minutes  
before proceeding.  
4. Lay the scanner down on its back, with the bottom facing you.  
5. Use a 2.5 mm allen key to remove the screws located at each of the  
four corners of the bottom panel (see Figure 6), then remove the  
bottom panel.  
1
3
4
2
Figure 6: To remove the bottom panel, remove the four screws at the  
positions shown. The numbers indicate the order in which they  
should be tightened when panel is replaced.  
continues...  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
18  
The Light Tube  
6. The light tube is clearly visible, as shown in Figure 7. Hold each end  
of the light tube between your thumb and index finger. Rotate the  
light tube until it comes free and pull it away from the scanner. Note  
that the light tube sockets allow the tube to be rotated all the way  
around, but they click into position at each quarter turn. The light  
tube is locked in place in all but one of these four positions, so you  
may need to try up to three positions before the light tube comes  
free.  
Feed Table (closed)  
The holes in the light tube  
sleeve must point forwards,  
towards the feed table.  
Light Tube  
Figure 7: Bottom view of the scanner with the bottom panel removed  
7. Install a new light tube following the reverse of the procedure you  
used when removing it. Make sure the sleeve is aligned correctly  
with the scanner as shown in Figure 5. Rotate the light tube and/or  
adjust the sleeve as necessary.  
8. Replace the bottom panel by holding it in place and tightening the  
screws in an opposite-diagonal sequence (e.g. top-left, bottom-right,  
top-right, bottom-left) as indicated in Figure 6.  
9. Turn on the scanner and check function of the new tube.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
19  
Cleaning the External Surface of the Scanner  
Cleaning the External Surface of the Scanner  
If the external surface of the scanner becomes dirty, then clean it with a  
damp cloth. Be careful not to get any moisture inside the scanner or on  
any of the connectors. Do not use alcohol or other solvents.  
Disposal  
If you need to dispose of the scanner, it must be delivered to an  
authorized waste plant for electronics equipment.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
20  
Technical Specifications  
Technical Specifications  
Power Connector:  
24 VDC  
60W  
Power Consumption  
Max. 60 W during operation  
Power Requirements  
100-240V AC, 1.3A, 50-60Hz  
Interface to Computer  
FireWire (IEEE 1394)  
Front Panel  
One multifunction switch (on/off switch) and status light  
Drum Force  
1kg (2.2lbs)  
Operating Environment  
Operating Temperature: 10 - 35°C (50 - 95°F)  
Recommended Working Temperature: 10 - 25°C (50 - 77°F)  
Relative Humidity: 20 - 80% RH (no condensation)  
Storage Environment  
Temperature: 0 - 50°C (32 - 122°F)  
Relative humidity: 20 - 80% RH (no condensation)  
Originals  
Transparencies from 35mm to 60x180 mm, < 1mm thick  
Light Tube  
OSRAM L6W/25 Universal White  
Dimensions  
Height: 400 mm (15.7")  
Width:  
Depth:  
265 mm (10.4")  
245 mm (9.6")  
(feed table closed)  
370 mm (14.6") (feed table in scan position)  
Weight  
7 kg (15.5 lbs)  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
21  
FCC Notice  
FCC Notice  
This equipment has been tested and found to comply with the limits for  
a Class A digital device, pursuant to Part 15 of the FCC Rules. These  
limits are designed to provide reasonable protection against harmful  
interference when the equipment is operated in a commercial  
environment. This equipment generates, uses, and can radiate radio  
frequency energy and, if not installed and used in accordance with the  
instruction manual, may cause harmful interference to radio  
communications. Operation of this equipment in a residential area is  
likely to cause harmful interference in which case the user will be  
required to correct the interference at his own expense.  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Hardware Reference - Flextight 343  
22  
CE - Declaration of Conformity  
CE - Declaration of Conformity  
HASSELBLAD A/S  
HEJREVEJ 30  
DK - 2400 COPENHAGEN NV  
TELEPHONE +45 7026 0800  
TELEFAX +45 7026 0900  
REG./VAT NO. 18635445  
Declaration of conformity  
Application of Council Directives: ................. 89/336/EEC amended by 92/31/EEC,  
93/68/EEC. 91/157/EEC.  
C73/23/EEC amended by 93/68/EEC.  
Standards to which Conformity is declared: EN61000-6-1 2001, EN61000-6-3 2001  
and EN60950:2000.  
Manufacturer: ........................................... Hasselblad A/S  
Hejrevej 30  
DK-2400 Copenhagen NV/  
Denmark  
Type of Equipment: .................................... Desktop CCD scanner  
Model name: ............................................ Flextight 343  
The undersigned, hereby declare that the equipment specified above conforms to the  
above Directives and Standards.  
Place ....................................................... Copenhagen NV  
Date ........................................................ September 12th, 2004  
Full name ................................................. Christian Poulsen  
Position .................................................... CEO  
Signature  
User's Guide - Flextight 343  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Cell Phone M10E User Manual
Greenheck Fan Air Conditioner ERVe User Manual
Grizzly Grinder G9928 User Manual
Grizzly Impact Driver H6186 User Manual
Hamilton Beach Slow Cooker 33966 User Manual
Harman Kardon Home Theater System 950 0321 001 User Manual
Hotpoint Double Oven UY46X2 User Manual
Husqvarna Motorcycle SM 400 450 R 2004 User Manual
Hypertec Carrying Case TAN3706HY User Manual
IKEA Dishwasher DW45 User Manual