Harman Stove Company Stove MARK I User Manual

Installation and Operating Manual  
Magnafire Series Coal Stoves - Mark I, II, and III  
R4  
SAFETY NOTICE  
PLEASE READ THIS ENTIRE MANUAL BEFORE YOU INSTALL OR USE YOUR NEW ROOM HEATER. FAILURE  
TO FOLLOW THESE INSTRUCTIONS MAY RESULT IN PROPERTY DAMAGE, BODILY INJURY, OR EVEN DEATH.  
APPROVED FOR USE IN THE U.S. AND CANADA  
IF THIS HARMAN STOVE IS NOT INSTALLED CORRECTLY, A HOUSE FIRE MAY RESULT. FOR YOUR SAFETY,  
FOLLOW INSTALLATION DIRECTIONS PRECISELY.  
CONTACT LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSPECTION REQUIREMENTS  
FOR YOUR AREA.  
CONTACT YOUR LOCAL AUTHORITY (SUCH AS THE MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT,  
FIRE PREVENTION BUREAU, ETC.) TO DETERMINE THE NEED FOR A PERMIT.  
CETTE GUIDE D’UTILISATION EST DISPONIBLE EN FRANCAIS. CHEZ VOTRE CONCESSIONNAIRE DE HARMAN  
HOME HEATING.  
Save These Instructions  
#3-90-70746  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Introduction  
Thank you for purchasing a Harman Magnafire coal stove. The Magnafire series has been designed  
and built to last. Whether you’re heating a room or heating your whole house, you’ve made the right  
choice. Please read this entire instruction manual before attempting to install or operate your new stove.  
If you have further questions regarding your new stove, contact your Harman dealer. Follow these in-  
structions and you will have many years of warmth and comfort enjoying your new coal stove.  
If you are a first-time coal burner, keep in mind that you will not have instant success with maintaining  
a fire. No one does. Following these instructions should help you with the basic principals.  
Please copy your serial number, from  
the label on the back of your stove, to  
the box below.  
Listed by: OMNI-Test Laboratories, INC  
Report # 135-S-07-4  
THis appliance is also approved for installation into a shop.  
Safety Notice:  
Stove is hot while in operation. Keep combustibles such as furniture, fuel, and  
draperies at least 36 inches away from the appliance.  
Do not leave small children unattended while in the room with this heater.  
Always wear gloves when attending to the stove.  
This stove is not an incinerator. Do not burn garbage, painted or treated wood, or  
flammable liquids like gasoline kerosene, or engine oil.  
3
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Index  
1.  
2.  
3.  
SaFeTy CoNSIderaTIoNS - Warnings to operator of possible dangers, fire hazards and cautions.  
1.1  
1.2  
1.3  
1.4  
Keep children away -- may cause serious burns  
Fuel/Firing Warnings  
Curing Paint  
Mobile Homes  
aSSeMbly & INSTallaTIoN  
2.1  
2.2  
2.3  
2.4  
Unpacking and Inspection of Parts  
locating The Stove  
assembly  
General Information  
VeNTING  
3.1  
3.2  
3.3  
3.4  
Types of Chimneys  
Common Chimney Problems  
What To do If you Have a Problem  
Chimney details  
4.  
5.  
GraTeS  
4.1  
Grate System and Controls  
oPeraTING INSTrUCTIoNS  
5.1  
5.2  
5.3  
5.4  
5.5  
5.6  
Starting a Fire  
loading Fuel  
Increasing Heat From a low Fire  
Shaking ashes  
ashes and ash removal  
Safety  
6.  
PreVeNTIVe MaINTeNaNCe INSTrUCTIoNS  
6.1  
Periodic and everyday Maintenance  
7.  
8.  
9.  
oPTIoNal HoT WaTer CoIl  
WarraNTy INForMaTIoN  
SerVICe ParTS dIaGraMS  
4
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
1. Safety Considerations:  
2. Assembly & Installation:  
1.1 KEEP CHILDREN AWAY - MAY CAUSE  
SERIOUS BURNS.  
2.1 UNPACKING AND INSPECTION OF  
PARTS.  
Inspect the stove for any visible damage. The blower  
and the shaker handle are packaged inside the stove.  
2.2 LOCATING THE STOVE.  
locate the stove as close to the chimney or flue as  
possible while adhering to the recommended clear-  
ances to combustible material. Safe stove clearance  
to combustible walls is 24” to the rear of the stove,  
and 33” to the sides of the stove. In a corner installa-  
tion, you need 24” to the side walls. Clearance to the  
front of the stove, for furniture, etc. is 36”  
Floor protection, for a combustible floor, must  
be a minimum of 3/8” thick non-combustible material.  
The floor protector should extend 8” to either side,  
and 16” in front of the stove. Floor protection should  
also be under any horizontal sections of flue pipe.  
CaUTIoN: all surfaces of the stove are hot while in  
operation. do not touch. Keep Children away. Wear  
gloves while tending stove. Serious burns will result if  
special care is not taken.  
1.2 FUEL / FIRING INFORMATION.  
daNGer! FIre HaZard! do NoT USe CHeMI-  
CalS or FlUIdS To STarT or “FreSHeN UP”  
a FIre. SeVere bodIly INJUry aNd/or a FIre  
IN THe HoMe May reSUlT. do NoT bUrN Gar-  
baGe, GaSolINe, THINNerS, KeroSeNe, or  
FUel oIl, eTC. aN eXPloSIoN, a HoUSe FIre  
or PerSoNal INJUry CoUld reSUlT. KeeP all  
SUCH lIQUIdS Well aWay FroM THe SToVe  
WHIle IN USe.  
8”  
This heater is approved for burning coal only.  
Use of any other fuel, except for the purpose of coal  
ignition, is a violation of U.S. law.  
8”  
8”  
When and if the chimney pipe or connector  
reaches 500˚ f. (maximum temperature), the stove is  
being over-fired. It is recommended that you use mag-  
netic thermometers on the stove and flue connector,  
to ensure safe operation.  
16” from glass  
Floor Protector  
This stove consumes air when it is burning.  
If your house is especially tight, It is advisable that a  
nearby window be opened slightly while burning the  
stove.  
Information in this manual is manufacturer’s  
recommendations. If there is a discrepancy between  
these recommendations and your local code require-  
ments, you must follow local codes.  
1.3 CURING PAINT.  
during the first few hours of burning, a blue smoke will  
be observed rising from the painted surfaces of the  
stove. This is the paint being cured, and will disap-  
pear over time. Increase the amount of fresh air in the  
room during this initial break-in period. This may be  
achieved by opening doors or windows.  
1.4 MOBILE HOMES.  
This stove is not approved for use in mobile /manu-  
factured homes.  
5
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation  
2.3 ASSEMBLY.  
2.4 GENERAL INFORMATION.  
Slide the blower into the slotted bracket on the rear  
of the stove. The blower will rest at the bottom of the  
slot.  
Installation Checklist:  
a. Have your stove installed by a trained installer.  
Preferably one who is certified by the National Fire-  
place Institute or similar certification agency.  
b. before starting Installation, check for proper clear-  
ance to combustibles where the stove is going to be  
located.  
C. Never vent a solid fuel burning appliance into a flue  
serving another appliance.  
d. Have the chimney inspected and thoroughly  
cleaned. Inspect that it is a Class “a” chimney either  
masonry or factory built. If it is a manufactured chim-  
ney, ensure that it is installed as per the manufactur-  
ers requirements. be sure that the chimney is tall  
enough. Solid fuel chimneys fall under a general rule,  
16 ft. minimum height, 2 ft. taller than anything within  
10 ft., and 3 ft. above where it passes through the  
roof line. The chimney must be capable of a minimum  
.06 inches of water column of draft when the stove is  
burning.  
The shaker handle bolts onto the shaker block using  
the bolts and lock washers provided.  
The draft control is bolted through the hole in the  
center of the ash door as shown below. The knob  
should spin freely and open to a distance of about 1/4  
inch from the door surface, while being able to close  
against the face of the door.  
The viewing glass is installed between the door and  
the window frame. The glass gasket is installed only  
on the sides of the glass panel. The top and bottom of  
the glass are open to provide air-wash and secondary  
air to the firebox. The glass frame is secured to the  
door with four bolts.  
The Mark II and Mark III also have a top trim piece  
which bolts onto the top of the door.  
be sure the frame bolts and trim bolts are secured.  
e. limit the amount of connector pipe. Position the  
stove as close to the flue as possible. (8 ft. or less)  
No more than two 90° elbow fittings should be used.  
any horizontal connector pipe should have at least 1/4  
in. of rise per foot in length. a barometric damper may  
be installed to prevent excessive or erratic draft.  
MANUAL DAMPERS OR “HEAT SAVERS” MUST  
NEVER BE INSTALLED IN THE FLUE PIPE. IM-  
PROPER OPERATION COULD RESULT IN DEATH.  
6
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Venting  
3.2 COMMON CHIMNEY PROBLEMS  
Where an existing chimney is used, it must be large  
enough to provide a draft adequate for removing the  
gaseous products of combustion. The cross-sectional  
area of the chimney must be at least 25 percent  
greater than that of the connector. as a general rule,  
common 8” X 8” flue liner has an actual interior cross-  
sectional area of 42 to 49 inches. This is adequate for  
a 6 inch stove connector, which matches the appli-  
ance flue collar.  
In order to have a properly operating heating system,  
the chimney needs to be capable of providing suf-  
ficient draft. The minimum required draft is .06 inches  
of water column (WC). To measure the draft, drill a  
hole in the connector pipe and attach a draft meter.  
First, check the draft above the barometric damper (if  
installed). Then check it below the barometric damper  
and make your damper adjustment to where it opens  
to prevent the draft from going higher than the .06  
in WC. If the chimney is incapable of supplying the  
necessary draft, it will need to be improved. Whether  
it needs to be raised to a taller height, a flue liner  
installed, or a different style of cap placed on the top,  
the improvement method will need to be determined.  
IMPORTANT! The connector pipe must be construct-  
ed of 24 gauge material or thicker.  
3. Venting & Chimneys:  
3.1 TYPES OF CHIMNEYS  
The chimney is one of the most important, yet the  
most neglected and misunderstood portion of any  
solid fuel burning appliance installation. do not con-  
nect your stove to a chimney flue that already serves  
another heating device.  
Reasons for insufficient draft;  
a) leaking chimney- air leaking in around a loose fit-  
ting cleanout door, joints or seams in connector pipe  
are not secured properly, cracks or other defects in  
masonry.  
b) Improper chimney height - Chimney does not  
extend to a sufficient height above the roof line. (re-  
member the 3 ft.-2 ft.-10 ft. rule)  
C) obstructions in the chimney - Make sure the chim-  
ney has been cleaned. different animals have been  
known to build nests in chimneys.  
The stove must be connected to its own flue. a mini-  
mum 8” X 8” is necessary for proper operation.  
Under no circumstances should a manual flue damper  
be installed in the smoke pipe between the stove and  
the chimney.  
CaUTIoN! THe CHIMNey MUST be a “ClaSS a”  
CHIMNey IN Good WorKING CoNdITIoN. THe  
USe oF alUMINUM “TyPe b” GaS VeNT For  
SolId FUelS IS NoT oNly UN-SaFe bUT IT IS  
ProHIbITed by THe NaTIoNal FIre ProTeC-  
TIoN aGeNCy (NFPa) Code.  
d) Trees or other topographical barriers - Trees that  
are taller than the house can cause the air currents to  
flow downward over the peak of the roof. This would  
lead to a down draft effect on the chimney. This can  
also be caused by adjacent buildings or fixtures. It  
could even be from a different peak on the same  
structure.  
There are three types of “Class a” chimneys;  
1) Masonry with a tile liner, including brick,  
block, stone, etc. It must be supported by a ground-  
level foundation.  
Wind direction  
2) Insulated “Class a” manufactured chimney,  
listed and certified by a national test agency.  
3) Triple-walled metal “Class a” chimney, listed  
and certified by a national test agency.  
If your masonry chimney has not been used for some  
time, have it inspected by a qualified person (building  
inspector, fire department personnel, etc.). If a listed  
and certified manufactured chimney is to be used,  
make certain it is installed in accordance with the  
manufacturers instructions and all local codes.  
a coal stove can perform only as well as its venting  
system will allow it to.  
7
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Venting & Grates  
e) Improperly sized flue - Too small of a chimney is  
4. Grates  
incapable of moving the volume of air necessary. Too  
large of a flue could have trouble warming up to cre-  
ate the necessary upward flow.  
F) Chimney offsets - offset chimneys should be  
avoided if possible. Not only can the offset affect draft,  
it is also a place for debris to collect over time.  
G) Too many elbows - The flue connector has more  
than two elbows in it. Sometimes, depending on  
overall chimney performance, one elbow could be too  
many.  
4.1 GRATE SYSTEM AND CONTROLS.  
The Grates are made of heavy-duty cast iron. The  
function of the grate system is to support the coal  
while allowing air flow through the fire. The grate sys-  
tem also allows removal of the ashes by shaking them  
through the grates.  
The grates are removable without the use of tools,  
once the fire bricks are removed, the grates simply  
lift out. lift the right end higher to disengage from the  
shaking link. To re-install the grates, lower them, one  
at a time, left end first, be sure the grate hooks into  
the grate link as you drop it into place.  
H) Vent sharing - No more than one heating appliance  
shall vent into a single flue.  
Stove body  
THe MoST IMPorTaNT THING To reMeMber  
aboUT CHIMNeyS IS THeIr Need For MaIN-  
TeNaNCe aNd CleaNING. IF a CHIMNey IS NoT  
CleaNed oN a FreQUeNT baSIS, IT WIll aF-  
FeCT draFT, aS Well aS be a CoNTrIbUTING  
FaCTor To a PoTeNTIal CHIMNey FIre.  
Grates  
Grate Link  
3.3 WHAT TO DO IF YOU HAVE A PROBLEM.  
If you have a chimney fire:  
1. Be sure everyone is out of the house.  
2. Call the fire department.  
Shaker Handle  
3. Close the draft control on the ash door and  
make sure both doors on the stove are closed  
and latched.  
4. Do not put water on the fire, this will cause un-  
necessary damage to the stove and flue.  
5. Have the chimney inspected and repaired prior  
to building another fire.  
Shaker Bar  
your grates will last forever, as long as you keep your  
ashes cleaned out of the stove. When ashes are left  
pile-up against the grates, the air-flow is blocked. With  
no air flow through the grates, they will begin to sag  
from the intense heat.  
The grates are designed to accommodate three differ-  
ent sizes of anthracite coal. Pea is defined as being  
able to fit through a round screen hole of 9/16” to 7/8”.  
Nut or Chestnut is defined as being able to fit through  
a round screen hole of 7/8” to 1½”. Finally , Stove coal  
which is 1½” to 2½” in size. Pea or Nut you’ll find work  
the best for starting a fire, while all three sizes burn  
just as well.  
Smoke puffs out of stove;  
a) Check previous suggestions for insufficient draft.  
b) Check draft control for proper operation.  
C) Chimney may be too low. Increase height.  
d) add more fresh air to the room. your home may be  
so tight that there is not enough oxygen getting to the  
fire.  
e) remember, open the draft control and crack the  
door open slightly before reloading or checking the  
fire.  
The external shaker handle allows for greater safety  
from burns, and the convenience of needing no extra  
tools.  
F) Check the ashes. The ash pan and firebox may be  
overloaded with ashes.  
G) Check the chimney cleanout door to ensure it  
closes properly.  
8
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation  
5. Operating Instructions  
5.3 INCREASING HEAT FROM A LOW FIRE  
5.1 STARTING A FIRE  
every effort should be made to not let a coal fire burn  
so long that it begins to die. This causes the reloading  
process to be much longer, and there is a good possi-  
bility of losing the fire all together. do not shake or stir  
a low fire. open the draft control or the ash door to get  
the maximum air flow. allow the fire to get reasonably  
hot. If there is not enough un-burned coal to renew  
the fire, add a small amount. Continue adding coal  
in small amounts until a full bed is established. Now,  
shake the grates. (see next section “shaking ashes”)  
Place seven or eight sheets of crumpled newspaper  
onto the top of the grates. Next, lay in some small kin-  
dling wood (approximately 3/4” or less) on top of the  
newspaper. layer the kindling in a criss-cross fashion  
to allow for maximum air flow. open the draft control  
to it’s full open position. light the paper nearest the  
center of the door opening and close and latch the  
load door. after two to three minutes, open the load  
door an inch or two for a few seconds, then open it  
completely. This method is good practice to allow  
smoke to clear away from the load door. add a few  
small pieces of firewood when the kindling is burning  
well. Close the door again and be sure the draft con-  
do NoT leaVe THe SToVe UNaTTeNded WITH  
THe door oPeN.  
5.4 SHAKING ASHES  
trol remains open. The ash door itself may be opened Shaking should be done only when there is a hot fire.  
for a short period to accelerate the process.  
The frequency of shaking will depend on the rate of  
burning. Shaking should be done at least once per  
day but best results will come from shaking twice a  
day.  
do NoT leaVe THe SToVe UNaTTeNded WITH  
THe door oPeN.  
When a substantial bed of hot wood coals are built  
up, start adding small amounts of coal on top of the  
When shaking, do just that. do not rock the handle in  
long strokes, just shake it briskly until you see red hot  
burning wood embers. (Pea or Nut sized coal will give ashes fall into the ash pan. rocking the grates may  
the best results when starting a fire.) Keep the draft  
control open through the whole ignition process. as  
the coal begins to free-burn, continue adding small  
amounts until there is a solid bed of burning coal. do  
not add too much at one time as you could smother  
the fire. allow sufficient time between these small  
batches so that the coal can ignite thoroughly before  
allow pieces of coal to jam them in an open position.  
5.5 ASHES AND THEIR REMOVAL  
ashes should never be allowed to accumulate in the  
ash pan. excess ash build up can restrict air flow to  
the fire and can also cause damage to the grates.  
ashes should be placed in a metal container with  
more is added. once a substantial bed is established, a tight fitting lid, pending final disposal. The closed  
fill the firebox to the top of the bricks. a deep bed of  
container of ashes should be placed on a non-com-  
coal will always burn better than a shallow bed. adjust bustible floor or on the ground, well away from any  
the draft control to the desired heat output. you’ll learn combustible materials. If the ashes are disposed of  
over time that the coal fire does not instantly change  
by burial in soil or otherwise locally dispersed, they  
with a turn of the draft control. Make your adjustments should be retained in the sealed container until all  
in small increments and wait for the fire to stabilize.  
The normal range of control settings will be from  
cinders have thoroughly cooled.  
closed, for extended burn times, to one full turn open. CaUTIoN! aSHeS SHoUld NeVer be alloWed  
To aCCUMUlaTe aboVe THe ToP oF THe aSH  
NoTe: If the ash door was opened during the light-  
ing process, it must be closed to prevent over-firing.  
PaN. aSHeS IN CoNTaCT WITH THe boTToM  
oF THe GraTeS aCT aS aN INSUlaTor INTeN-  
over-firing can cause dangerously high temperatures. SIFyING THe HeaT oN THe GraTeS, aNd WIll  
CaUSe THe GraTeS To WarP. GraTe daMaGe  
FroM aSH bUIld UP IS eaSIly reCoGNIZed.  
PleaSe reFer To yoUr WarraNTy To See  
HarMaN SToVeS lIMIT oF lIabIlITy IN CaSeS  
5.2 LOADING  
Coal should never be added unless there is a reason-  
ably hot fire. The coal bed should be bright and vigor-  
ous. If the fire is burning hot and there is a deep bed  
oF abUSe or NeGleCT.  
of hot coals, full loads of coal can be added at any  
Coal produces considerably more ash than wood. For  
time. However, if there is not a deep bed of coals, it is  
equal heat output, coal will produce 7 to 10 times the  
best to add in small batches as during lighting.  
ash of a wood fire.  
9
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
5.6 SAFETY  
To clean the chimney, use a stiff brush with an extend-  
able handle. Start the brush from the top of the chim-  
ney and run it down through the flue. Continue brush-  
ing until the entire length of the chimney is cleaned.  
The debris will collect at the bottom of the chimney.  
open the cleanout door or other access point and  
sweep the collection into a metal container. The con-  
nector pipe can be brushed also, remove it from the  
stove if possible, to eliminate pushing the debris into  
the stove’s spiral chamber.  
Whenever a loading door is opened, it should always  
be cracked slightly to allow oxygen to enter and burn  
any gasses that may be present. Failure to do this  
may result in a sudden ignition of the gasses, leading  
to an explosion.  
a Stove should never be filled with excess coal to  
where the exhaust is impeded. burning coal gener-  
ates carbon monoxide. If the flue gas exit is blocked,  
the carbon monoxide can be forced out of the stove  
and into your living space, with fatal consequences.  
Ashes should be kept in a metal container with  
a tight fitting lid. The closed container of ashes  
should be placed on a non-combustible floor or  
on the ground, well away from all combustible  
materials, pending final disposal. If the ashes are  
disposed of by burial in soil or otherwise locally  
dispersed, they should be kept in the closed con-  
tainer until all cinders have thoroughly cooled. Do  
not use this same container for garbage, debris,  
or lawn waste.  
With the exception of start-up or freshening a fire,  
the ash pan door should never be left open. NeVer  
leaVe THe SToVe UNaTTeNded WITH a door  
oPeN. Serious damage to the stove can occur from  
over-heating.  
Coal stoves should not be installed in a chimney that  
has a history of down-draft or flow reversal problems.  
These conditions can cause improper draft, resulting  
in carbon monoxide entering the living space rather  
than being drawn up the chimney. reMeMber!  
Coal GaSeS are ToXIC!  
Sulfur dioxide, sulfur trioxide and other products of  
coal combustion may corrode stainless steel and  
masonry chimneys. Coal with high sulfur content will  
destroy chimneys especially fast if soot is left in the  
flue for extended periods. It is important to clean your  
chimney regularly.  
This is the Spiral  
Chamber which  
must be cleaned  
periodically.  
6. Maintenance  
6.1 PERIODIC AND EVERYDAY MAINTENANCE  
blower: Monthly, remove the blower and clean the  
fan. If there are pets in your house, you may want to  
check this more frequently.  
Secondary air  
enters through the  
air -wash opening  
in the glass frame.  
Grates: Keep ash pan emptied. Twice a day.  
Chimney and connector: avoid chimney fires. on a  
regular schedule, check for creosote and soot build up  
in the venting and the baffle area of the stove. These  
areas must be kept clean.  
Primary air enters  
through the draft  
control.  
Steel brushes are the safest for cleaning metal surfac-  
es. Salt solutions and other chemicals may damage  
the metal surfaces.  
10  
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Water Coil  
7. Optional Hot Water Coil:  
Plumbing Diagrams-  
Washer  
Inside Nut  
Outside Nut  
Packing  
Stove Body  
11  
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Optional Water Coil  
To install the optional hot water coil, Two holes will need to be drilled or cut into the side of the stove. There is  
a template for the hole location(s) that is included with the coil. Keep the holes above the firebricks and toward  
the back of the firebox. This location is best to not interfere with loading.  
Thermo- Siphon Method  
This is the simple and most economical method, however, the hot water tank must be no more than ten feet  
from the stove. The water inlet, where the pressure relief valve is located, must be higher than the top leg of  
the coil. The tank should be elevated, if necessary, to allow for proper thermo-siphon action (the method by  
which water will circulate automatically through the system).  
Circulating Pump Method  
This method is used when the water heater tank can not be located close enough to the stove for the Thermo-  
Siphon Method, or if the water tank is on a lower floor level than the stove. In addition to the circulating pump,  
you may want to add an aquastat to thermostatically control the pump. This is optional and not necessary if the  
pump is left run continuously. another option would be a gate valve placed near the pump to control the rate of  
water flow.  
read and follow all of the instructions that are included with the coil.  
12  
Magnafire Series Coal Stoves  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8. Warranty Information:  
Hearth & Home Technologies Inc.  
LIMITED LIFETIME WARRANTY  
Hearth & Home Technologies Inc., on behalf of its hearth brands (”HHT”), extends the following warranty for  
HHT gas, wood, pellet, coal and electric hearth appliances that are purchased from an HHT authorized dealer.  
WARRANTY COVERAGE:  
HHT warrants to the original owner of the HHT appliance at the site of installation, and to any transferee taking ownership  
of the appliance at the site of installation within two years following the date of original purchase, that the HHT appliance  
will be free from defects in materials and workmanship at the time of manufacture. After installation, if covered compo-  
nents manufactured by HHT are found to be defective in materials or workmanship during the applicable warranty period,  
HHT will, at its option, repair or replace the covered components. HHT, at its own discretion, may fully discharge all of its  
obligations under such warranties by replacing the product itself or refunding the verified purchase price of the product  
itself. The maximum amount recoverable under this warranty is limited to the purchase price of the product. This warranty  
is subject to conditions, exclusions and limitations as described below.  
WARRANTY PERIOD:  
Warranty coverage begins on the date of original purchase. In the case of new home construction, warranty coverage  
begins on the date of first occupancy of the dwelling or six months after the sale of the product by an independent,  
authorized HHT dealer/ distributor, whichever occurs earlier. The warranty shall commence no later than 24 months  
following the date of product shipment from HHT, regardless of the installation or occupancy date. The warranty period for  
parts and labor for covered components is produced in the following table.  
The term “Limited Lifetime” in the table below is defined as: 20 years from the beginning date of warranty coverage for  
gas appliances, and 10 years from the beginning date of warranty coverage for wood, pellet, and coal appliances. These  
time periods reflect the minimum expected useful lives of the designated components under normal operating conditions.  
Warranty Period  
Parts Labor  
HHT Manufactured Appliances and Venting  
EPA  
Components Covered  
Gas  
X
Wood Pellet  
Coal Electric Venting  
Wood  
All parts and material except as  
covered by Conditions,  
Exclusions, and Limitations  
listed  
1 Year  
X
X
X
X
X
X
Igniters, electronic components,  
and glass  
X
X
X
X
X
X
2 years  
X
X
X
Factory-installed blowers  
Molded refractory panels  
3 years  
X
X
Firepots and burnpots  
Castings and baffles  
5 years 1 year  
X
X
Manifold tubes,  
HHT chimney and termination  
7 years 3 years  
X
X
10  
1 year  
years  
X
X
X
Burners, logs and refractory  
Firebox and heat exchanger  
Limited  
3 years  
Lifetime  
X
X
X
X
X
X
X
X
All replacement parts  
beyond warranty period  
90 Days  
X
X
See conditions, exclusions, and limitations on next page.  
4021-645C 12-29-10  
Page 1 of 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
WARRANTY CONDITIONS:  
This warranty only covers HHT appliances that are purchased through an HHT authorized dealer or distributor. A list of  
HHT authorized dealers is available on the HHT branded websites.  
This warranty is only valid while the HHT appliance remains at the site of original installation.  
Contact your installing dealer for warranty service. If the installing dealer is unable to provide necessary parts, contact  
the nearest HHT authorized dealer or supplier. Additional service fees may apply if you are seeking warranty service  
from a dealer other than the dealer from whom you originally purchased the product.  
Check with your dealer in advance for any costs to you when arranging a warranty call. Travel and shipping charges  
for parts are not covered by this warranty.  
WARRANTY EXCLUSIONS:  
This warranty does not cover the following:  
Changes in surface finishes as a result of normal use. As a heating appliance, some changes in color of interior and  
exterior surface finishes may occur. This is not a flaw and is not covered under warranty.  
Damage to printed, plated, or enameled surfaces caused by fingerprints, accidents, misuse, scratches, melted items,  
or other external sources and residues left on the plated surfaces from the use of abrasive cleaners or polishes.  
Repair or replacement of parts that are subject to normal wear and tear during the warranty period. These parts  
include: paint, wood, pellet and coal gaskets, firebricks, grates, flame guides, light bulbs, batteries and the discolor-  
ation of glass.  
Minor expansion, contraction, or movement of certain parts causing noise. These conditions are normal and com-  
plaints related to this noise are not covered by this warranty.  
Damages resulting from: (1) failure to install, operate, or maintain the appliance in accordance with the installation  
instructions, operating instructions, and listing agent identification label furnished with the appliance; (2) failure to  
install the appliance in accordance with local building codes; (3) shipping or improper handling; (4) improper opera-  
tion, abuse, misuse, continued operation with damaged, corroded or failed components, accident, or improperly/  
incorrectly performed repairs; (5) environmental conditions, inadequate ventilation, negative pressure, or drafting  
caused by tightly sealed constructions, insufficient make-up air supply, or handling devices such as exhaust fans or  
forced air furnaces or other such causes; (6) use of fuels other than those specified in the operating instructions; (7)  
installation or use of components not supplied with the appliance or any other components not expressly authorized  
and approved by HHT; (8) modification of the appliance not expressly authorized and approved by HHT in writing;  
and/or (9) interruptions or fluctuations of electrical power supply to the appliance.  
Non-HHT venting components, hearth components or other accessories used in conjunction with the appliance.  
Any part of a pre-existing fireplace system in which an insert or a decorative gas appliance is installed.  
HHT’s obligation under this warranty does not extend to the appliance’s capability to heat the desired space. Informa-  
tion is provided to assist the consumer and the dealer in selecting the proper appliance for the application. Consider-  
ation must be given to appliance location and configuration, environmental conditions, insulation and air tightness of  
the structure.  
This warranty is void if:  
The appliance has been over-fired or operated in atmospheres contaminated by chlorine, fluorine, or other damaging  
chemicals. Over-firing can be identified by, but not limited to, warped plates or tubes, rust colored cast iron, bubbling,  
cracking and discoloration of steel or enamel finishes.  
The appliance is subjected to prolonged periods of dampness or condensation.  
There is any damage to the appliance or other components due to water or weather damage which is the result of, but  
not limited to, improper chimney or venting installation.  
LIMITATIONS OF LIABILITY:  
The owner’s exclusive remedy and HHT’s sole obligation under this warranty, under any other warranty, express or  
implied, or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specified above. In no  
event will HHT be liable for any incidental or consequential damages caused by defects in the appliance. Some states  
do not allow exclusions or limitation of incidental or consequential damages, so these limitations may not apply to you.  
This warranty gives you specific rights; you may also have other rights, which vary from state to state. EXCEPT TO  
THE EXTENT PROVIDED BY LAW, HHT MAKES NO EXPRESS WARRANTIES OTHER THAN THE WARRANTY  
SPECIFIED HEREIN. THE DURATION OF ANY IMPLIED WARRANTY IS LIMITED TO DURATION OF THE  
EXPRESSED WARRANTY SPECIFIED ABOVE.  
4021-645C 12-29-10  
Page 2 of 2  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9. Service Parts  
Service Parts  
Mark I  
Beginning Manufacturing Date: N/A  
Ending Manufacturing Date: Active  
Magnare Freestanding Coal Stove  
1-70-03224-1 (Black), 1-70-03224-2 (Charcoal), 1-70-03224-3 (Goldenre), 1-70-03224-4 (Metallic Blue),  
1-70-03224-10 (Mojave Red), 1-70-03224-12 (Forest Green)  
1
2
3
4
5
IMPORTANT: THIS IS DATED INFORMATION. When requesting service or replacement  
parts for your appliance please provide model number and serial number. All parts listed  
in this manual may be ordered from an authorized dealer.  
Stocked  
at Depot  
ITEM  
DESCRIPTION  
COMMENTS  
PART NUMBER  
1-10-08145A  
1-00-00139-1  
1-00-00139-4  
4-00-00038-1  
3-00-00038-4  
3-40-7251050  
4-00-00109-1  
3-00-00109-4  
3-40-00086-3-3  
1-10-01001  
1
Load Door - Roped  
Door Kit Assembly  
Black classic  
No longer available  
Cast  
Door Kit Assembly (Gold)  
Glass Frame  
2
No longer available  
Glass Frame (Gold)  
Rect Glass 7-1/4” X 10-1/2”  
Draft Control  
Y
Cast  
No longer available  
Pkg of 3  
Draft Control (Gold)  
Spring Handle 1/2”  
3
4
5
Short Shaker Handle Weldment  
Ash Door - Roped  
Y
1-10-08143A  
Additional service parts on following page  
02/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Parts  
Mark I  
Beginning Manufacturing Date: N/A  
Ending Manufacturing Date: Active  
IMPorTaNT: THIS IS daTed INForMaTIoN. When requesting service or replacement  
parts for your appliance please provide model number and serial number. all parts listed  
in this manual may be ordered from an authorized dealer.  
Stocked  
at Depot  
ITEM  
DESCRIPTION  
COMMENTS  
PART NUMBER  
ash Pan  
baffle  
1-10-65127  
2-00-00503b  
3-21-07584  
1-00-900450125  
2-00-01006  
1-00-00836  
4-00-00042  
1-00-00036  
4-30-00138b  
1-00-53500  
1-00-98187  
3-00-00193  
3-00-00203  
3-00-00208  
4-00-00044P  
1-10-02015W  
2-00-01037-1  
2-00-01037-2  
Y
blower - 75cfm, 7ft Cord  
brick 9” X 4-1/2” x 1-1/4”  
brick bracket  
Y
Y
Pkg of 7  
brick Set  
Y
Y
Y
Y
Y
Y
Y
Y
Y
door Handle - Cast  
door latch  
4 Sets  
door Pin 3/8 x 1-7/8 (ash Pan & load door)  
Gasket 1/2” round rope (load door - ash door )  
Gasket, 5/8” Channel(Glass)  
Grate Holder 2 - Cast  
Grate link 2 - Cast  
Pkg of 4  
Mag Grate 15” - Cast (2 per)  
Mag leg - Cast  
Shaker bar Weldment 1-1/2”  
Shaker block  
Y
Y
Y
Shaker Handle Mount  
02/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Parts  
Mark II  
Beginning Manufacturing Date: N/A  
Ending Manufacturing Date: Active  
Magnafire Freestanding Coal Stove  
1-70-03225-1 (Black), 1-70-03225-2 (Charcoal), 1-70-03225-3 (Goldenfire), 1-70-03225-4 (Metallic Blue),  
1-70-03225-10 (Mojave Red), 1-70-03225-12 (Forest Green)  
1
2
3
4
5
IMPorTaNT: THIS IS daTed INForMaTIoN. When requesting service or replacement parts for  
your appliance please provide model number and serial number. all parts listed in this manual may  
be ordered from an authorized dealer.  
Stocked  
at Depot  
ITEM  
DESCRIPTION  
COMMENTS  
PART NUMBER  
1-10-08140a  
1-00-00141-1  
1-00-00141-4  
4-00-00037-1  
3-00-00037-4  
3-40-8501494  
3-40-450850  
4-00-00109-1  
3-00-00109-4  
3-40-00086-3-3  
1-10-01001  
1
load door - roped  
Y
door Kit assembly  
Classic black  
No longer available  
Cast  
door Kit assembly (Gold)  
Glass Frame  
2
No longer available  
Glass Frame (Gold)  
rect Glass 8-1/2” X 14-15/16”  
rect Glass 4-1/2” X 8-1/2” (Triple Frame)  
draft Control  
Y
Y
Cast  
No longer available  
Pkg of 3  
draft Control (Gold)  
Spring Handle 1/2”  
3
4
5
Short Shaker Handle Weldment  
ash door  
Y
Y
Cast  
4-00-00213d  
additional service parts on following page.  
02/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Parts  
Mark II  
Beginning Manufacturing Date: N/A  
Ending Manufacturing Date: Active  
IMPorTaNT: THIS IS daTed INForMaTIoN. When requesting service or replacement parts for  
your appliance please provide model number and serial number. all parts listed in this manual may  
be ordered from an authorized dealer.  
Stocked  
at Depot  
ITEM  
DESCRIPTION  
COMMENTS  
PART NUMBER  
ash Pan  
baffle  
1-10-00722  
2-00-00360b  
3-21-07584  
1-00-900450125  
2-00-01006  
1-00-00837  
4-00-00042  
1-00-00036  
4-30-00138a  
1-00-53500  
1-00-98187  
3-00-00193  
3-00-00203  
3-10-49201  
4-00-00034-1  
3-00-00034-4  
3-00-00211  
Y
blower - 75cfm, 7ft Cord  
brick 9” X 4-1/2” x 1-1/4”  
brick bracket  
Y
Y
Pkg of 7  
brick, Set of cut  
Y
Y
Y
Y
Y
Y
Y
Y
door Handle  
Cast  
door latch  
4 Sets  
Pkg of 4  
door Pin 3/8 x 2-1/4 (load door)  
Gasket 1/2” round rope (load door - ash door)  
Gasket, 5/8” Channel (glass)  
Grate Holder - Cast  
Qty 2 req  
Qty 2 req  
Grate link 2 - Cast  
Hot Water Coil  
load door Top  
Cast  
No longer available  
Qty 2 req  
load door Top (Gold)  
Mag Grate 20” - Cast  
Y
Mag leg - Cast  
4-00-00044P  
1-10-02015W  
2-00-01037-1  
2-00-01037-2  
4-30-00138b  
3-30-0101-100  
3-30-1125-100  
Shaker bar Weldment 1-1/2”  
Shaker block  
Y
Y
Y
Y
Y
Y
Shaker Handle Mount  
Short door Pin 3/8 x 1-7/8 (ash Pan)  
5/16” Zinc Plated Split lock Washer  
5/16-18 x 3/4” Grade 5 Zinc Plated Hex Cap Screw  
Pkg of 4  
Pkg of 100  
Pkg of 100  
02/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Parts  
Mark III  
Beginning Manufacturing Date: N/A  
Ending Manufacturing Date: Active  
Magnafire Freestanding Coal Stove  
1-70-03227-1 (Black), 1-70-03227-2 (Charcoal), 1-70-03227-3 (Goldenfire), 1-70-03227-4 (Metallic Blue),  
1-70-03227-10 (Mojave Red), 1-70-03227-12 (Forest Green)  
1
2
3
4
5
IMPorTaNT: THIS IS daTed INForMaTIoN. When requesting service or replacement  
parts for your appliance please provide model number and serial number. all parts listed  
in this manual may be ordered from an authorized dealer.  
Stocked  
at Depot  
ITEM  
DESCRIPTION  
COMMENTS  
PART NUMBER  
1-10-08140a  
1-00-00141-1  
1-00-00141-4  
4-00-00037-1  
3-00-00037-4  
3-40-450850  
3-40-8501494  
4-00-00109-1  
3-00-00109-4  
3-40-00086-3-3  
1-10-01001  
1
load door - roped  
door Kit assembly  
Y
Classic black  
No longer available  
Cast  
door Kit assembly (Gold)  
Glass Frame  
2
No longer available  
Glass Frame (Gold)  
rect Glass 4-1/2” X 8-1/2” (Triple Frame)  
rect Glass 8-1/2” X 14-15/16”  
draft Control  
Y
Y
Cast  
No longer available  
Pkg of 3  
draft Control (Gold)  
Spring Handle 1/2”  
3
4
5
Short Shaker Handle Weldment  
ash door  
Y
Y
Cast  
4-00-00213d  
additional service parts on following page  
02/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service Parts  
Mark III  
Beginning Manufacturing Date: N/A  
Ending Manufacturing Date: Active  
IMPorTaNT: THIS IS daTed INForMaTIoN. When requesting service or replacement  
parts for your appliance please provide model number and serial number. all parts listed  
in this manual may be ordered from an authorized dealer.  
Stocked  
at Depot  
ITEM  
DESCRIPTION  
COMMENTS  
PART NUMBER  
ash Pan  
baffle  
1-10-00723  
2-00-00378b  
3-21-13584  
1-00-900450125  
2-00-01006  
1-00-00838  
4-00-00042  
1-00-00036  
4-30-00138b  
4-30-00138a  
1-00-98187  
1-00-53500  
3-30-2001-50  
3-00-00194  
3-00-00204  
3-10-49201  
4-00-00034-1  
3-00-00034-4  
3-00-00211  
Y
blower - 135cfm, 7ft Cord  
brick 9” X 4-1/2” x 1-1/4”  
brick bracket  
Y
Y
Pkg of 7  
brick, Set of cut  
Y
Y
Y
Y
Y
Y
Y
Y
Y
Y
door Handle  
Cast  
door latch  
4 Sets  
Pkg of 4  
Pkg of 4  
door Pin 3/8 x 1-7/8 (ash Pan)  
door Pin 3/8 x 2-1/4 (load door)  
Gasket 5/8” Channel (Glass)  
Gasket 1/2” round rope (load door - ash door)  
1/4-20 x 1/2” Grade 8.2 Zinc Sae Flange bolt  
Grate Holder - Cast  
Pkg of 50  
Qty 3 req  
Qty 4 req  
Grate link - Cast  
Hot Water Coil  
load door Top  
Cast  
No longer available  
Qty 3 req  
load door Top (Gold)  
Mag Grate 20” - Cast  
Mag leg - Cast  
Y
4-00-00044P  
1-10-02015W  
2-00-01037-1  
2-00-01037-2  
2-00-01100-1d  
Shaker bar Weldment 1-1/2”  
Shaker block  
Y
Y
Y
Shaker Handle Mount  
Side brick angle  
02/11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service & Maintenance Log  
Date Of Service  
Performed By  
Description Of Service  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Service & Maintenance Log  
Date Of Service  
Performed By  
Description Of Service  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Proudly Printed On 100% Recycled Paper  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grundig Stereo System CDS 6580 A SPCD User Manual
Harman Kardon Stereo System AVR 125 User Manual
Harrington Hoists Personal Lift ED1050 User Manual
Hasbro Electronic Keyboard 87 001 User Manual
HP Hewlett Packard Server 512485 B21 User Manual
H P Products All in One Printer PRO 8500 User Manual
HTC Cell Phone SAPP100 User Manual
Hunter Fan Air Cleaner 30075 User Manual
Hyundai Portable DVD Player H CMD4004 User Manual
Impex Home Gym SB 208 User Manual