Harman Stove Company Stove Harman Stove The Harman Magnum Stoker User Manual

Installation & Operating Manual  
The Harman Magnum Stoker  
Tested by:  
DO NOT BURN WET COAL.  
R15  
OMNI-TEST Laboratory  
SAFETY NOTICE  
PLEASE READ THIS ENTIRE MANUALBEFORE YOUINSTALL AND USE YOURNEW ROOM HEATER. FAILURE TO  
FOLLOW INSTRUCTIONS MAY RESULT IN PROPERTYDAMAGE, BODILYINJURY, OR EVEN DEATH.  
FOR USE IN THE U.S. AND CANADA.  
IF THIS HARMAN STOVE IS NOT PROPERLY INSTALLED,AHOUSEFIREMAYRESULT. FORYOURSAFETY, FOLLOW  
INSTALLATIONDIRECTIONS.  
CONTACT LOCAL BUILDING OR FIRE OFFICIALSABOUT RESTRICTIONSAND INSTALLATIONINSPECTION  
REQUIREMENTS INYOUR AREA.  
CONTACT YOUR LOCAL AUTHORITY (SUCHAS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE  
PREVENTION BUREAU,ETC.) TO DETERMINE THENEED FORA PERMIT.  
CETTEGUIDE D'UTILISATIONEST DISPONIBLEENFRANCAIS.CHEZVOTRECONCESSIONNAIRE DEHARMANSTOVE  
COMPANY.  
SAVETHESEINSTRUCTIONS.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
3
INTRODUCTION  
ThisallnewdesignbyHarmanfeaturestheVerti-FlowStokerSystem.  
THERMOSTAT  
This unique system provides a very wide range ofheat output. The  
Verti-FlowStokercanoperatefrom5000toover85,000btu'sautomatically.  
Thisunit hasa100pound coalcapacityandcan provide85,000btu's  
for17hoursorstretchout toover100hourswhen lessheat isrequired.  
Athermostatisusedtoregulatetheheatoutputofthestove. Whenno  
heatisneeded,thestokerstopsandonlyrunstomaintainthefire. Ifheatis  
needed,thethermostatcanturnonthestokeratanytime. Afterthethermostat  
issatisfied,thestokerwillturnofffortwelveminutesandthenrunforfour  
minutes.  
100 LBS.  
COAL  
The fourminutes "on" and twelveminutes "off" is a settingthat will  
performwellundermostconditions.This"on"and"off"timecanbechanged  
toprovidemoreorlessheatduringthemaintenancecycle.  
WARNINGS  
This unit must be connected to a chimney capable ofprovidinga .04  
minimumdraftreading.WARNING!!Ifthechimneyhasnodraft,coalgases  
mayescapefromtheunitandstovepipe.Thesegasesaretoxicand can be  
fatal. It is recommended that a gas detector be installed to warn of this  
condition. Checkwithyourlocalstovedealerforpurchasingagasdetector.  
Never sleep in the same  
room with any coal  
burning stove.  
TESTING INFORMATION  
This unit hasbeen tested and approved by OMNI-TESTLabo-  
ratoriesinaccordancetothelistedcodes.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
4
READ THIS  
Always empty hopper when not burning for more than a  
week. When left standing for long periods with wet coal,  
the pusher block will rust and corrode, causing it to  
seize. If the stoker is then turned " on" , damage to the  
pusher assembly and feed motor will result. This will be  
considered neglect and will void the warranty on those  
parts. Always check to see if moving parts are free  
before using if the unit has not been burned for a period  
of time. This can best be determined by shaking the  
adjuster rod.  
Damp Coal  
Wet Coal  
Freshly delivered coal is watered down  
to eliminate dust when loading and unloading.  
Wet rice coal does not flow as well as damp or  
dry coal. We do not recommend burning wet  
coal, however, we realize if it's the only coal you  
have it is better to burn it than freeze. If you  
must burn wet coal, the feed rate must be in-  
creased in order to get the same size fire. As the  
wet coal in the hopper dries out, the feed rate  
must be decreased. If you don’t, the feeder will  
over-fire the stove and waste coal. Doing this  
once or twice a year will not damage your stove  
as long as it is hot and burning. The damage is  
caused when the hopper has wet coal in it when  
the stove is cold. This will cause rust and corro-  
sion and it is totally the operator’s fault.  
Usually after the coal dries for three  
or four days, depending on conditions, it will  
flow very well and feed properly. Feed rate  
will be the same as dry coal.  
Damp coal also should not be left in  
the hopper of a cold stove.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
5
PACKING LIST  
Parts inside feeder box  
Pusher block  
adjuster rod  
Restricter Plate  
wing nut  
thermostat  
adjuster tube  
control box  
adjuster  
Inside bag  
(2) terminals for thermostat wire  
(4) 8-32 x 1/2 screws and nuts  
motor cover  
Parts inside stove  
(2) grate inserts  
main feeder body  
firebricks  
Parts inside hopper box  
grate holder  
hoppersupport  
hopper lid  
distribution blower  
combustion blower  
scraper  
assembly  
hopper  
ash pan  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6
ASSEMBLY  
adjuster rod  
Pusher  
block  
slot  
First,anotetoyou,thecustomer.  
ThissectiononAssemblyisinthemanualforyourinformation  
shouldyoueverneedtomoveyourunitandtohelpyouunder-  
standhoweachpartisinstalled.  
ItisnotintendedbyHarmanStoveCompanythatyou  
assemblethisunit. ThisjobistobeperformedbyyourHarman  
Dealerwhohasbeentaughthowtoassembleandexplainthe  
operationofyournewstokertoyou.  
dust tray  
feed indicator  
fig 1  
Yourdealerwillalsotake adraft readingwith thestoker  
burning. Thisreadingmustberecordedonthewarrantycouponin  
ordertoactivateyourwarranty.  
The assembly and set-up arefree. However, we do not  
wishtoimplythatdeliveryandinstallationarefree.  
adjuster tube  
wing nut  
adjuster  
fig 2  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
7
Feeder  
Beginassemblybyslidingthepusherblockwiththe  
adjusterrodfromthefrontthroughtheslotshownin fig.1.  
Besurethepusherblockisturnedwiththeboltholeto  
Blowers  
feedindicatorside.  
Next,holdpusherblockin themostrearward posi-  
gasket  
tionandslidetheadjustertubeovertheadjusterroduntilit  
bottomsoutonthepusherblock. Threadtheadjuster  
overtheadjusterrod.Threadwingnutontheendofthe  
adjusterrod.  
Make sure the gasket is in place on the feeder  
Control Box  
openingontherearoftheunit,asshowninfig3.Insertthe  
stokerintotheopeningintherearoftheunit.Boltfastand  
tighten with (2)5/16X 11/4bolts.  
fig 3  
Installthesmallerofthetwoblowersonthebottom  
ofthefeederbyslidingitinto thebracketasfarasitwill  
go.Installrestricterplateonblowerasshownbelowin  
Fig. 4.  
thermostat  
Slidethe largerblowerintoplaceon thebottomrear  
Cleanout Scraper  
Install scraper as shown below with locking nut  
on each side of the scraper. Tighten nuts when in the  
rear most position to assure alignment. Cycle rod in  
and out to clean unit.  
lock nut  
scraper  
Restricter Plate  
Control Box  
Small blower  
Largeblower  
fig 4  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
8
Hopper  
Install hopper support on top rear of stoker.  
Note that bolt holes in hopper support are slotted for adjust-  
ment. Insert small end of hopper into the hopper slot on the feeder  
as shown. Push top of hopper under the hopper support, causing  
the slot on the bottom side of the support to hook onto the hopper.  
The hopper support will spring up slightly for the hopper to go  
under. If you have difficulty getting the hopper under, adjustment  
may be necessary. Use slotted holes shown at left. Now the feed  
motor cover can be installed.  
hoppersupport  
slotted holes  
Grate  
The grate is composed of four pieces:the grate holder, (2)  
grate inserts, and grate angle. The grate angle is bolted to the  
grate holder with (2) 3/8 X 1 1/4 bolts. Before installing the grate  
holder, 3/8" round gasket must be checked in the groove on the  
botton side of the grate holder, as shown in fig. 7. Check to be sure  
the gasket has not been damaged.  
Grate insert  
fig 5  
.
The grate holder must be installed through the top door  
opening after the feeder has been installed.  
Grate  
angle  
Locate the flange at the rear of the grate holder into the slot  
on the feeder as shown below. Bolt the front end down with the  
1/4 x 20 Allen bolt and nut provided. The rear end will be locked  
in place by the flange. Before tightening the bolt be sure the grate  
holder is back as far as possible and centered side to side on the  
feeder opening.  
Install grate inserts as shown at left. Divide the spaces  
between the inserts equally and be sure they are not tight. The  
spaces are needed for expansion.  
Grate holder  
fig 6  
firebricks  
Install firebricks  
asShown  
Gasket  
IMPORTANT  
Be sure the grate holder  
is centered and back as  
far as possible.  
fig 7  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
9
Top View  
Front  
18"  
34"  
barometric  
damper  
8"  
16"  
34"  
8"  
minimum 4"  
IMPORTANT  
UseonlyU.L.approvedfloor  
board  
Clearance to Combustibles  
IMPORTANT  
INSTALLATION  
Takedraft readingbetweenthe  
barometricdamperandthe  
stove.Dothisonpilotmode.  
Place the stoker a minimum of 4" to a com-  
bustible wall from the rear of the hopper and a  
minimum of 34" from the sides. The stove should  
be placed on a noncombustible floor. Install a 6"  
stove pipe from flue opening to chimney with a  
barometric damper. Secure all pipe joints with  
sheet metal screws. Plug power cord into a 120  
volt receptacle.  
draft  
adjustment  
Refer to the section on operation to light a  
fire. With the stove burning and stabilized set  
barometric damper at .04 to .06 on the draft meter.  
We do not expect you to own a draft meter. There-  
fore, have your dealer do set-up and fine tuning.  
If your chimney will not produce .04 on the  
draft meter, a draft inducer should be installed by  
your dealer. The draft inducer will provide the  
additional draft needed for proper operation.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Fine Tuning Draft  
10  
With fire burning and stablized  
take draft reading in flue pipe and note  
the reading. Next take a reading in the  
fire box by removing the bolt in the front  
center of the unit.  
While watching the draft meter,  
close the restricter plate on the combus-  
tion blower slowly, until the needle  
reads about the same as it did on the  
flue. An example would be a flue read-  
ing of .05 and a firebox reading of .02.  
Close the restricter plate until the  
firebox reading is .04 to.05. Closing the  
restricter plate will reduce the positive  
pressure from the blower and increase  
the negative pressure in the firebox.  
WARNING!  
If draft is at .00, carbon monoxide  
will escape into the room. Too  
much carbon monoxide can kill  
you.  
Timer settings shown above will perform well in most cases.  
Verti-Flow Stoker Control  
This section describes the features and opera-  
tions of The Harman Verti-Flow Stoker Control.  
The timers are adjustable from 0 minutes to 15  
minutes in 1 minute steps. There are red lights on the  
front panel to show proper operation of the timer.  
One indicator shows power is applied to the unit.  
The other 3 indicators show when power is available  
at the adjacent receptacle.  
The stoker control will be mounted on the side  
panel of the feeder directly below the coal hopper.  
The three receptacles and switch will be facing  
forward. The power cord, 3 AMP fuse access port  
and the thermostat connections to the rear.  
The top receptacle provides power to the coal  
feeder motor. Thus, the plug from the coal feeder  
motor should be inserted into this receptacle.  
The center receptacle provides power for the  
combustion blower motor. Thus, the plug from the  
combustion blower should be inserted into this  
receptacle.  
The bottom receptacle provides power for the  
distribution blower motor. Thus, this final receptacle  
should be connected to the plug from the distribution  
blower motor.  
Restricter Plate  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
11  
ofthe stove. NOTE: The bolt holes onthe blowers are not  
used.  
Installthecontrolboxonmountingpadprovidedonthe  
side ofthe stoker with (4) #8-32bolts. NOTE:The recep-  
taclesgotowardthefront.  
Plugthegearmotorintothetop,thesmallcombustion  
blowerintothemiddle,andthelargedistributionblowerinto  
thebottomreceptacleonthecontrolboxasshown.Moreon  
thecontrollater.  
Thethermostatconnectionsonthebackpanelofthe  
StokerControlare.25inchmalequickconnectterminals.  
Thematingconnectors(supplied)shouldbe.25inchfemale  
quickconnectorterminals. Thewireshouldbenosmaller  
than22gauge.  
Thethermostatconnectionsshouldonlybeconnected  
acrossthethermostatswitchinsidethethermostatunit.This  
switchisthetypewhichopens(turnsoff)whenthesetpoint  
temperatureisreached,andcloses(turnson)whentheroom  
temperaturefallsbelowthetemperature. (Thisisthetype  
suppliedwiththeunit.)  
Place thermostat in a central location.  
Do not place it in an isolated room with  
poor air circulation  
TheACpowercord shouldbethelastconnection  
made. Thepowercord should be plugged intoa 115AC  
volt60hertzwalloutlet,whichhaspropergroundingavail-  
able. This 115AC voltwalloutlet shouldalso becapable of  
handling3ampsofcurrentbecausethisisthemaximum  
amperagethisunitwilldraw.  
Basic Theory of Operation  
Afterthestokercontrolisproperlyinstalled,operation  
ofthestovemaybegin.Thestoveoperationiscontrolled  
fromthethermostat. Thismeansiftheroomtemperatureis  
coolerthanthetemperaturesetonthethermostat,thestove  
willbeginoperationwiththestokercontrolintheinactive  
state. Oncetheroomtemperaturereachesthethermostatset  
pointtemperature,thecombustionblowerandcoalfeeder  
willturnoff,butthedistributionblowerwillstilloperate. At  
thispoint,thestokercontrolhastakencontrolofthestove's  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
12  
operation. Thetimerwillcontinuetocontrolthestoveuntil  
theroomtemperaturedropsbelowthethermostatsetpoint  
temperature. Atthistime,thestovewilloperateconstantly  
untiltheroomtemperaturereachesthethermostatsetpoint  
againandthecyclerepeats.  
Itshouldbenotedthatthetimeradjustmentsdohavea  
0minuteposition. Thedefaultconditionsfortheseadjust-  
mentssetfor0minutesareasfollows:"on time"0,"offtime"  
0unitwillrunconstantly;"ontime"greaterthanO,"offtime"  
0,unitwillrunconstantly;"ontime"0,"offtime"greaterthan  
0,unitwillcycleonandoffwiththe"off"timebeingthe  
controllingtimer. Itisnotrecommendedthatthe0minute  
timebeusedonanyoftheadjustments. The0minutetimeis  
aninvalidconditiononthestokercontrol.  
Whenthestokercontrolfirsttakescontrolinthe  
maintenancecycle,twotimersareactivated,the"distribution  
blower"timerandtheunit"off"timer.  
The"distributionblower"timerisanoffdelaytimer.  
Thismeansafterthecombustionblowerandcoalfeederturn  
offthedistributionblowerwilloperateforaprogrammed  
periodoftimebeforeturningoff. Thestokercontroltiming  
rangeforthisfunctionis0minutesto15minutes.  
Thepurposeofhavingtheoffdelaytimerontodistri-  
butionbloweristoexhausttheexcessheatinthestovethat  
isinherentafterthecombustionblowerandcoalfeederturn  
off. Forthis reason,itisnotrecommendedthat a0time  
settingbeused.Thiswillminimizeanypossibilityofover-  
heatingthestove.  
Theothertimer,whichbeginswhenthestokercontrol  
firsttakescontrol,isthe"off"timer.Thisfunctionofthe  
stokercontrolisadjustablefrom0minutesto15minutes.  
Programmingthistimerwithavalveletsthestokertimer  
knowhowlongtokeepthecombustionblowerandthecoal  
feederturnedoffbetweenmaintenancecycles.  
Oncetheofftimerhasfinishedtimingandtheroom  
temperaturehasnotfallenbelowthethermostatsetpoint,the  
"on"timerfunctionwillbegin. Theprogrammablerangefor  
thisfunctionisalso0minutesto15minutes.Oncethe"on"  
timerhasstarted,alloutput(combustionblower,distribution  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
13  
blower,coalfeeder)receptacleswillbecomeactiveforthepro-  
grammedamountoftime.When"on"timerhasfinishedtiming,the  
stokercontrolwillrecycleandthe"distributionblower"timeralong  
withthe"off"timerwillonceagainbecomeactive.  
Thefinaloperatorinterfaceistheswitchonthefrontpanel  
adjacenttothereceptacles. Thisswitchinthe"on"positionallows  
powertothecoalfeedermotorreceptacle. Inthe"off"position,  
powerwillberemovedonlyfromthecoalfeedermotorreceptacle.  
Thisswitchinthe"off"position,willstopthecoalfrommoving  
acrossthegratesandallowforeasylightingofthefire.Oncethe  
firehasbeenestablishedmovetheswitchtothe"on"position.  
How to Operate the Stoker Control  
Thereare fouroperatorinterfaces onthe stokercontrol.  
The operatorinterfaces areone rockerswitch andthree, 16-  
positionrotaryswitches.  
Therockerswitchisapowerswitchthatcontrolsonlythe  
coalfeedermotor. Fornormaloperation,thisswitchshouldbe  
placedinthe"on"position. Thisswitch'soperationcanbeverified  
byasmallredlightabovethecoalfeederreceptaclebeingonwhen  
theswitchison.  
Ifthe stoveneedstobe shutdown,simplyplace therocker  
switchinthe"off"position. Thesmalllightabovethecoalfeeder  
receptaclewillturnoff.  
Theotherthreeswitchesarethecustomer's adjustmentsfor  
thetimers(ontime,offtime,distributionblowertime).These  
switchescanadjusteachtimerindividuallyfrom1minuteto15  
minutesin1minuteincrements. Donotsettimersto0.  
The"on"timeandthe"off"timeshouldbeprogrammedtoa  
minimumtimethatkeepsthecoalburningduringthemaintenance  
cyclingmode. Thedistributionblowertimeshouldbeprogrammed  
foratimewhichislongenoughtomovetheexcessheatfromthe  
stovetotheroomheated. Ifthistimeisprogrammedforalonger  
timethanthe"off"timethedistributionblowerwilloperatecon-  
stantly. Thiswillhavenodamagingeffectonthestokercontrol.  
Recommendedtimersettingstostartare,"on"4minutes,  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
14  
OPERATION  
"off"12minutes,extendtimer2minutes. Youmayfindthatthese  
settingsproducetoomuchheatinpilotmode. Ifso,youcanreduce  
the"on"timeandincreasethe"off"time. However,beawarethat  
you can gotoo farand havethe fire go out. It is bestto adjust one  
minuteatatime.  
Tostart afire youfirst pourrice coalinto thehopper. With the  
thermostatturnedupandthestokerrunning,thecoalwillbeginto  
feedonto thegrate insidethestove. Thisprocess canbe speededup  
byadjustingthefeedratetothemaximumposition. Whenthecoal  
startsto comeup outofthegrate andis almostup tothe areawhere  
theholesstart, turnthefeedratebacktoabout3/8"and turnoffthe  
feedmotorwiththe switchonthe sideofthestoker. Placesome  
feed indicator  
crumblednewspaperandfinekindling(6"to8"long)onthegrateand  
ignite. Whenkindlingisburninggood,addsomericecoalontopof  
it. Afterthecoalisburning,the feedmotorcanbeturnedonandthe  
coalfirewillcontinuetogetlarger. Freshcoalwillcontinuetobe  
pushedontothegrateandasheswillbepushedoffthegrate. The  
feedratemustbeadjustedsothe coalisburnedupandturnedto  
ashesbefore thecoalgets oneinchfrom theend ofthegrate. Too  
highafeedratewillpushunburnedcoaloffthecoalgrate,therefore  
Feed Adjustment  
Adjust feed rate by turning adjuster clockwise to  
increase and counterclockwise to decrease. Each complete  
turn will move the fire about 1".  
The feed indicator on the side of the feeder shows how  
far the pusher moves each stroke. There are dots above the  
indicator spaced 1/8 " apart. A movment of one dot would  
give a low burn, two dots medium and three dots high.  
Lock adjuster with wing nut after adjusting.  
See drawings at left.  
Low feed rate  
WASTING COAL  
POSSIBLE DAMAGE TO UNIT  
Over Fired, No Good  
Max feed rate  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
15  
Cycle in and out  
willnotburncompletely.  
Afterthefireisburningandthefeedrateisadjusted,youcan  
nowsetthethermostattothedesiredtemperature.  
MAINTENANCE  
Witheachhopperofcoalthatisburnedapproximatelyone  
ashpanfullofashesmustberemoved.Failuretoremovetheashes  
willresultinablockedupgrateandthefirewillnotburnproperly.  
Remember,theashpanwillbehot,soalwayswearprotectivegloves.  
Weekly:  
Thesmalltrayinthesideofthestokershouldberemovedand  
emptied.  
Thespringhandlelocatedattherearoftheflue-pipeshouldbe  
cycledinandoutseveraltimes.Thisactioncleanstheinteriorofthe  
heatexchangerandcausesthedusttofallintotheashpan.  
Every3Months:  
Slide open  
clean-out slide  
Thegrate"clean-out"slideshouldbeopenedandreclosedas  
shownindrawingsatleft.  
Inthe"closed"position,besurethe"grate clean-out"plateslide  
isstraightacrossasshown.  
Theeasiestwaytohandlethisslideisthroughtheashdoorwith  
apokerinserted intotheholeat theend.  
Thepurposeofthisoperationistoletanyflyashbuild-upunder  
thegratefallintotheashpan.  
Slide closed  
Thisoperationcanbeperformedwhiletheunitisburning.  
However,youshouldfirstlowerthethermostattolowerthestove  
temperatureandbesureyouarewearingprotectivegloves.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
16  
Thisoperationcanalsobeperformedwhentheunitisnotburning  
byliftingoutthegrateinsertsandremovingflyashwiththevacuum  
cleaner.  
Annually:  
Attheendoftheheatingseasonisthebesttimetoperformannual  
maintenance. Thereasonisrustandcorrosioncanformmuchfasterin  
thehighhumidityofsummer.  
Removeallcoalfromhopper.  
Removeallashes.  
Removeandcleanfluepipe.  
Checkchimneyandcleanifnecessary.  
è
IMPORTANT  
Removehopperandcheckforrustatbottomedges.Ifrustis  
found,removeitwithafileorsandpaperandpainttheareawith spray  
paintavailablefromyourdealer.  
Checkthefeederforrustandcorrosionwherethehopperfitsinto  
it.  
Checkthe pusherblocktosee ifitmoves freely.This canbest be  
donebyshakingtheadjusterrod.Ifitdoesnotmovefreely,itshouldbe  
removedandcleaned.Alsoremoveanyrustorcorrosionfromthearea  
wherethepusherblockslidesandspraywithWD-40orotherrust  
preventingspray. Toremovepusherblock--Removecover,remove  
wingnut,adjuster,andadjustertube.Removemotormountwithmotor  
inplaceandcordstillattached.Swingpusherassemblyupashighasit  
willgo.RemovefeedindicatorfromsidewithAllenwrench. Nowthe  
pusherblockcan beremoved. To reinstall--justreverse the  
procedure.Ifthepusherblockcannotbemoved,callyour  
dealer.  
è
IMPORTANT  
Alwaysemptyhopperwhennotburningformorethana  
week. Whenleftstandingforlongperiodswithwetcoal,the  
pusherblockwillrustandcorrode,causingittoseize. Ifthe  
stokeristhenturned"on",damagetothepusherassemblyand  
feedmotorwillresult. Thiswillbeconsideredneglectandwill  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
17  
voidthewarrantyonthoseparts. Alwayschecktoseeifmovingparts  
arefreebeforeusingiftheunithasnotbeenburnedforaperiodoftime.  
Thiscanbestbedeterminedbyshakingtheadjusterrod.  
TROUBLE-SHOOTING  
FEEDING PROBLEMS  
Wet Coal --Wet coal does not flow the same as dry coal. There-  
fore,the feedratewillchangewith wetcoal.Ifitistoo wet,it maynot  
feed at all. Wet coalcan also cause a sulfurodor.  
WrongSizeCoal--The Verti-FlowSystemisdesigned toburn  
rice(orbuckwheatcoalifriceis notavailable)Ifbuckwheatcoalis  
burned,raise thedraftsettingfrom.04to.06. Largercoalwillnotfeed  
orburnproperly.  
HopperBlocked--Sometimeswood, paper,orotherforeign  
objectsaccidentlyendupinyourcoalbinandcanslowdownorblock  
theflowofcoal. Youmayhave toemptythehopperto findtheblock-  
age.  
PusherOutOfAdjustment--Thiscanhappenwhenmorethan  
onepersontends thestoker. One persondoesnottellotherswhat  
adjustmentsweremade.  
GasAlarmBuzzesorSulfurOdorExists--Asulfursmellmaybe  
noticedwhenthetopdoorisopenedduringoperationwithwetor  
dampcoal. Thisisnormal.However,itisnotrecommendedthatwet  
coalbeused orthe topdoorbe openedformore than afew seconds  
whileburningtoinspectthefire.  
Lackofdraftoradowndraftinthechimneywillcausegasesto  
escapefromtheunit. Nostovewillfunctionproperlywithoutdraft.Any  
draftproblemshouldbecorrectedbeforeuse.  
Adraftinducermaybeinstalledtoincreasedraftinmarginal  
situations.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
18  
Theinstallationshouldbeperformedbyyourdealerwhoisfactory  
trainedtocorrectanyproblemoninitialstart-up. Afterproperinstallation,  
manyyearsoftrouble-freeoperationcanbeexpected.  
Stoker ControlTrouble-Shooting  
Thistrouble-shootingguideisdesignedtohelpthecustomerfindbasic  
problemsexternaltothestokertimer.Ifaproblemcannotbelocatedby  
usingthisguide,servicingofthestokercontrolorreplacementmaybe  
required. Thisshouldbedonebyqualifiedpersonnel.  
PROBLEM:Nomotorsorlightswillturnon.  
Checkthe AC powercord to the stokercontrol.  
Checkthe3ampfuseonthe sidepanelofthe stokertimer.(Replace  
onlywitha3amp slowblowfuse.)  
PROBLEM:Lightsonthestokercontrolareon,butmotorswillnot  
operate.  
ChecktheACpowerplugsfromthemotors(aretheysecurely  
pluggedintothecorrectoutlet.)  
PROBLEM:Oneofthemotorswillnotoperate.  
Checkifthelight abovethereceptacle islit. Checkthe ACpower  
plugfromthemotor(isitsecurelypluggedintothecorrectoutlet.)  
PROBLEM:Themotorsarecyclingonandoff,butnotinthecorrect  
order.  
ChecktheACpowerplugsfromthemotors(aretheysecurely  
pluggedintothecorrectoutlet.)  
PROBLEM:Coalfeedermotorwillnotturnon.  
Checkiftheredlightislit,ifnot,checkifthefeedmotorswitchis  
turnedon.  
PROBLEM:Themotorsturnonandoffasprogrammed,butthe  
roomtemperatureisbelowthethermostatsetting.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
19  
Checktheconnectionsfromthestokercontroltothethermostat.  
Checkthethermostatforproperoperation.  
PROBLEM:Themotorsdonotturnoffevenwhentheroomtempera-  
tureisabovethethermostatsetpoint.  
Checkthattheprogrammedofftimeisnotfor0minutes.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
20  
Feeder Parts  
8
7
1
C
J
9
G
H
16  
G
D
15  
G
G
6
10  
C
J
3
13  
J
7
D
14  
F
12  
2
11  
E
I
22  
A
B
18  
21  
4
D
C
B
B
17  
20  
L
A
K
K
19  
5
K
A
A
1. (2)grate inserts  
2. grate holder  
3. grate angle  
16. motor cover  
17. cam arm cover  
18. cam arm  
A (4) 1/4 x 5/8  
B (3) 1/4 " nut  
C (3) 3/8 x 1 1/4  
4. feeder body  
5. clean-out slide  
6. pusher arm  
7. (2) pillow block bearings  
8. feed motor  
19. dust tray  
D (3) 3/8 flat washer  
E (2) 3/8 nuts  
20. feed indicator  
21. cam bearing  
22. gasket  
F (1) 1/4 x 1 1/4 Allen  
G (4) 10-32 x 5/8 Allen  
H (1) 8-32 screw and nut  
I (1) 1/4 x 1/2 grade 8  
J (3) 5/16 x 3/4  
9. capacitor  
10. motor mount  
11. pusher block  
12. adjuster rod  
13. adjuster tube  
14. adjuster  
K (3) 5/16 nuts  
L (1) 1/4 x 5/8 button head  
15. wing nut  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
21  
Domestic hot water coil hookup  
temperature  
pressure  
relief valve  
aquastst  
automatic air  
valve  
valve  
electric hot water heater  
circulator pump  
valve  
Cut holes with 1 1/8" hole saw where  
shown . Install coil with hardware provided.  
Hook up as shown above. If distance between  
unit and tank is less than 10 feet the circula-  
tor pump and aquastat are not needed. Aq-  
uastat is to turn on pump when water reaches  
about 140 degrees in systems over 10 feet  
apart.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
22  
Hot Air Duct Option  
6" starting collar  
Important  
Don't forget to retighten the  
bolt after removing the  
plate.  
Your stoker has a built-in feature that lets you take the air that normally blows out from the front and  
puts it out the top into a 6" duct.  
To do this, remove the 6" round plate from the top of the unit by removing the bolt located in the top of  
the firebox. A 3/4" wrench will fit the bolt. Remove the plate from the front by using the small handle on the  
plate. Turn bolt all the way in and tighten.  
Next, block off the front blower opening with a piece of heavy fiberglass rope. Insert rope through the  
6" duct opening and push front to block off the front air passage.  
Now, install a 6" starting collar in the 6" hole and run duct to desired room.  
NOTE: THIS DUCT OPTION IS INTENDED TO SUPPLY ONE REGISTER ONLY,  
WITH A MAXIMUM DISTANCE OF 20 FEET FROM UNIT.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  
23  
HARMAN GOLD WARRANTY  
6 YEAR TRANSFERABLE LIMITED WARRANTY  
(Residential)  
1 YEAR LIMITED WARRANTY (Commercial)  
Harman Stove Company warrants its products to be free from defects in material or workmanship, in normal  
use and service, for a period of 6 years from the date of sales invoice and for mechanical and electrical failures, in  
normal use and service, for a period of 3 years from the date of sales invoice.  
If defective in material or workmanship, during the warranty period, Harman Stove Company will, at its option,  
repair or replace the product as described below.  
The warranty above constitutes the entire warranty with respect to Harman Stove Company products.  
HARMAN STOVE COMPANY MAKES NO OTHER WARRANTY, EXPRESSED OR IMPLIED, INCLUDING  
“ANY” WARRANTY OF MERCHANTABILITY, OR WARRANTY OF FITNESS FOR A PARTICULAR  
PURPOSE. No employee, agent, dealer, or other person is authorized to give any warranty on behalf of Harman Stove  
Company. This warranty does not apply if the product has been altered in any way after leaving the factory. Harman  
Stove Company and its agents assume no liability for “resultant damages of any kind” arising from the use of its  
products. In addition, the manufacturer and its warranty administrator shall be held free and harmless from liability  
from damage to property related to the operation, proper or improper, of the equipment.  
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE  
HEREOF.  
THESE WARRANTIES APPLY only if the device is installed and operated as recommended in the user’s  
manual.  
THESE WARRANTIES WILL NOT APPLY if abuse, accident, improper installation, negligence, or use  
beyond rated capacity causes damage.  
HOW TO MAKE A CLAIM - Any claim under this warranty should be made to the dealer from whom this  
appliance was purchased. Then contact is made with manufacturer, giving the model and serial numbers, the date of  
purchase, your dealer’s name and address, plus a simple explanation of the nature of the defect. Extra costs such as  
mileage and overtime are not covered. Nuisance calls are not covered by these warranties.  
THIS WARRANTY IS LIMITED TO DEFECTIVE PARTS - REPAIR AND/OR REPLACEMENT  
AT HARMAN STOVE COMPANY’S OPTION AND EXCLUDES ANY INCIDENTAL AND CONSE-  
QUENTIAL DAMAGES CONNECTED THEREWITH.  
WARRANTY EXCLUSIONS: Failure due, but not limited to, fire, lightning, acts of God, power failures and/or  
surges, rust, corrosion and venting problems are not covered. Damage and/or repairs including but not limited to;  
remote controls, filters, fuses, knobs, glass, ceramic brick panels, ceramic fiber afterburners, door packing, tile,  
ceramic log sets, paint, batteries or battery back-up and related duct work are not covered. Also excluded from this  
warranty are consumable or normal wear items including but not limited to; flame guides, grates, coal bars, after-  
burner hoods, fire brick, gaskets. Additional exclusions for corn stoves are burnpot housing weldment, burnpot grate  
weldment (pellet or corn), burnpot front plate (pellet or corn), burnpot front plate lock, corn auger extension, ceramic  
insert, and ceramic insert plate. Additional or unusual utility bills incurred due to any malfunction or defect in equip-  
ment and the labor cost of gaining access to or removal of a unit that requires special tools or equipment are not  
covered. Maintenance needed to keep the stove in “good operating condition” is not covered. This includes, but is  
not limited to, cleaning, adjustment of customer controls and customer education. Labor, materials, expenses and/or  
equipment needed to comply with law and/or regulations set forth by any governmental agencies are not covered.  
This Warranty provides specific legal rights and the consumer may have other rights that vary from state to  
state.  
In the event of change in ownership, the remaining portion of this warranty may be transferred to the new  
owner by sending the new owner information and a transfer fee of $25.00 US to the Harman Stove Company.  
PLEASE READ THE LITERATURE BY THE MANUFACTURER FOR THE VARIOUS ACCESSORY  
DEVICES. THE MANUFACTURER WARRANTS THESE ACCESSORY DEVICES, NOT HARMAN STOVE  
COMPANY OR THEIR WARRANTY ADMINISTRATOR. FURTHERMORE, THESE ACCESSORY DEVICES  
MUST BE INSTALLED AND USED ACCORDING TO THE RECOMMENDATIONS OF THE MANUFAC-  
TURER.  
REMEDIES - The remedies set forth herein are exclusive and the liability of seller with respect to any contract  
or sale or anything done in connection therewith, whether in Contract, in tort, under any warranty, or otherwise, shall  
not, except as herein expressly provided, exceed the price of the equipment or part of which such liability is based.  
CLARIFY - The above represents the complete warranty, which is given in connection with stoves, manufac-  
tured by Harman Stove Company. No other commitments, verbal or otherwise, shall apply except by a written  
addendum to this warranty.  
DO NOT BURN WET COAL  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Grizzly Drill G0705 User Manual
Halfords Pressure Washer HP 1400 User Manual
Hasbro Games 03488 User Manual
Heat Glo LifeStyle Indoor Fireplace GRAND I35 User Manual
HP Hewlett Packard Photo Scanner 30 130 User Manual
HP Hewlett Packard Weather Radio HP4916A User Manual
Hunter Fan Fan 22437 User Manual
Husqvarna Lawn Mower YTH210XP User Manual
Ikelite Digital Camera S5 IS User Manual
Impex Home Gym TSA 5000 User Manual