Harbor Freight Tools Water Pump 46750 User Manual

DIRTY WATER SUBMERSIBLE  
PUMP - STAINLESS STEEL  
46750  
ASSEMBLY AND OPERATING INSTRUCTIONS  
3491 Mission Oaks Blvd., Camarillo, CA 93011  
Copyright © 2001 by Harbor Freight Tools®. All rights reserved. No portion of  
this manual or any artwork contained herein may be reproduced in any shape  
or form without the express written consent of Harbor Freight Tools.  
For technical questions and replacement parts, please call 1-800-444-3353  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6.  
7.  
8.  
Keep children away. Children must never be allowed in the work area. Do not let  
them handle machines, tools, or extension cords.  
Store idle equipment. When not in use, tools must be stored in a dry location to  
inhibit rust. Always lock up tools and keep out of reach of children.  
Dress properly. Do not wear loose clothing or jewelry as they can be caught in  
moving parts. Protective, electrically nonconductive clothes and nonskid footwear are  
recommended when working. Wear restrictive hair covering to contain long hair.  
9.  
Use eye and ear protection. Always wear ANSI approved impact safety goggles.  
10. Do not overreach. Keep proper footing and balance at all times. Do not reach over  
or across electrical cables or frames.  
11. Stay alert. Watch what you are doing, use common sense. Do not operate any tool  
when you are tired.  
12. Check for damaged parts. Before using any tool, any part that appears damaged  
should be carefully checked to determine that it will operate properly and perform its  
intended function. Check for alignment and binding of moving parts; any broken parts  
or mounting fixtures; and any other condition that may affect proper operation. Any  
part that is damaged should be properly repaired or replaced by a qualified  
technician. Do not use the tool if any switch does not turn On and Off properly.  
13. Replacement parts and accessories. When servicing, use only identical  
replacement parts. Use of any other parts will void the warranty. Only use accessories  
intended for use with this tool. Approved accessories are available from Harbor  
Freight Tools.  
14. Use proper power outlet. This pump has a three prong plug. The third prong (round)  
is the ground. Plug the pump cord only into a three-prong, Ground Fault Circuit  
Interrupter receptacle. Cutting off the ground prong will result in a safety hazard and  
void the warranty.  
15. Using Extension Cords. An extension cord up to 50 feet must have a wire size of 18  
AWG; up to 100 feet must have a wire size of 16 AWG. Do not submerge extension  
cords or make contact with water.  
16. Use the right tool for the job. Do not attempt to force a small tool or attachment to  
do the work of a larger industrial tool. There are certain applications for which this tool  
was designed. Do not modify this tool and do not use this tool for a purpose for which  
it was not intended.  
17. Do not operate tool if under the influence of alcohol or drugs. Read warning  
labels on prescriptions to determine if your judgment or reflexes are impaired while  
taking drugs. If there is any doubt, do not operate the tool.  
18. Pacemaker safety warning. People with pacemakers should consult with their  
physician(s) before using this product; operation of equipment in close proximity to a  
heart pacemaker could cause interference or failure of the pacemaker.  
Note: Performance of this tool may vary depending on variations in local line voltage. Exten-  
sion cord usage may also affect tool performance.  
SKU 46750  
Page 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Warning: The warnings, cautions, and instructions discussed in this instruction manual  
cannot cover all possible conditions and situations that may occur. It must be under-  
stood by the operator that common sense and caution are factors which cannot be  
built into this product, but must be supplied by the operator.  
Unpacking  
When unpacking, check to make sure all parts are included. Refer to the Parts Diagram at  
the end of this manual. If any parts are missing or broken, please call Harbor Freight Tools  
at the number on the cover of this manual.  
Operation  
1.  
2.  
Connect drain hose to the Output Tie-in (30) discharge fitting.  
This hose should be long enough to drain away from the reservoir being pumped. See  
installation examples on the next page.  
If the pump needs to be lowered into a pool or other deep reservoir, attach a rope to  
the pump handle and lower into position. Never suspend the pump from the power  
cord or discharge pipe.  
The pump should rest on a flat, level, and solid foundation. Never operate on earth,  
clay, sand, or gravel surfaces. Keep the pump inlet opening clear of debris. If the drain  
piping runs in excess of 10 feet, it is recommended to use a check valve (not  
included) to prevent back flow. To avoid air locks in the pump, drill an 1/8 inch hole in  
the piping, between the check valve and the pump. Refer to the top-right illustration on  
the next page.  
Warning: Never use the line cord to carry the pump. Do not run the pump dry. It will  
increase wear to the unit and cause possible seal damage.  
3.  
Connect the Power Cable to the Ground Fault Interrupter receptacle to begin  
pumping.  
Caution: The Float Switch must be floating in water for the pump to operate. It is meant  
to shut off intermittently. Do not attempt to manipulate the switch to keep the pump  
running continuously. Doing so will damage the pump.  
Warning: Never allow the power cord or extension cord connection (if used) to come in  
contact with ground water.  
SKU 46750  
Page 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Ground Fault  
Circuit Interrupter  
DANGER  
Electrical  
Connection  
ON  
H2O  
H2O  
H2O  
H2O  
DANGER Never Touch Switch (#11)  
or Water During Pump Operation  
1/8” HOLE  
Recommended  
Check Valve  
Removing Underground  
Water Accumulated From  
Rain Gutter  
ON  
H2O  
H2O  
OFF  
ON - OFF Switch  
Operation  
House Sump  
SKU 46750  
Page 5  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
S Y M P TO M  
C AU S E  
S O LU T IO N  
N o power  
Im p ellerblocked  
Check pow ersource;R esetG FCI  
Free im peller(see M aint.)  
The pum p w illnotstart  
Therm alprotection shutdow n Allow pum p to cooldown;auto restart  
Entangled FloatSw itch  
Check FloatSw itch  
Pum p subm erged too deep  
Discharge pipe bent  
Reduce subm ersion depth  
Free bends fro m p ipe  
The pum p operates but Suction grid clogged  
C lean suction grid  
pum ps little orno w ater Air locked in suction base  
Turn offpum p for10 seconds  
O ptionalcheck valve stuck or Exam ine check valve  
installed backwards  
Excessive noise or  
vibration  
W orn bearings  
Debris in im peller  
H ave a qualified technician repair  
Clean outim pellerinlet  
W atertem pe rature too h igh  
Neveruse pum p in waterover95  
degrees F.  
Pum p starts and stops  
too frequently  
D efective orentangled Float  
Sw itch  
Replace orreposition sw itch  
W aterbackflow  
Installa check valve atthe outlet  
Maintenance  
Warning: Disconnect power before performing any mainte-  
nance.  
1.  
Periodically clean the suction section of the pump,  
removing any foreign particles. Run in clean water to  
flush out system.  
2.  
3.  
To remove particles stuck on the impeller, remove the  
screws on the Base bottom, and pull Base off.  
Any other maintenance must be done by a qualified  
technician.  
SKU 46750  
Page 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Parts List  
ꢀꢋꢌ ꢍꢎ  
ꢄꢌꢏꢐꢑꢒꢓꢋꢒꢔꢕ  
ꢀꢌꢖꢗꢇ~ꢁꢝꢠ  
'(ꢃꢚꢜ  
;
ꢚꢌꢃꢇ'ꢛꢚꢙꢙ  
ꢚꢌꢃꢇꢓꢁꢡꢚꢃ  
ꢒꢝꢤꢞꢎꢂꢇJꢎꢛꢚꢃ  
~ꢚꢌꢃꢖꢗꢘ  
>
ꢁꢂꢁꢃ  
#
~ꢚꢌꢃꢖꢗꢘ  
E
'ꢂꢌꢂꢁꢃ  
ꢏꢐ  
ꢏꢏ  
ꢏ;  
ꢏꢄ  
ꢏꢆ  
ꢏ>  
ꢏꢔ  
ꢏꢋ  
ꢏ#  
ꢏE  
;ꢐ  
;ꢏ  
;;  
;ꢄ  
;ꢆ  
;>  
;ꢔ  
;ꢋ  
;#  
;E  
ꢄꢐ  
ꢄꢏ  
ꢄ;  
ꢄꢄ  
'(ꢃꢚꢜ  
'ꢜꢖꢂ(ꢛ  
ꢓꢌDꢙꢚꢇꢌꢗꢝꢇꢉꢙꢞꢘ  
?ꢞꢂ  
Jꢎꢛꢚꢃ  
ꢈꢌꢗꢝꢙꢚ  
ꢓꢌꢍꢌ(ꢖꢂꢁꢃ  
ꢓꢌDꢙꢚꢇ/ ꢍꢌ(ꢂꢖꢗꢘ  
'(ꢃꢚꢜ  
Rꢃꢁꢗꢂꢇꢓꢁꢡꢚꢃ  
'ꢚꢌꢙꢚꢝꢇ+ꢌꢂꢚꢣ  
/ ꢍꢚꢙꢙꢚꢃ  
?ꢞꢂ  
'ꢚꢌꢙꢚꢝꢇ+ꢌꢂꢚꢣ  
Jꢎꢛꢚꢃ  
?ꢞꢂ  
Rꢖꢣꢇꢖꢗꢘ  
'ꢚꢌꢙꢚꢝꢇ+ꢌꢂꢚꢣ  
~ꢌꢎꢚ  
'ꢖꢍꢛꢁꢗ  
Qꢞꢂꢍꢞꢂꢇ%ꢖꢚ!ꢖꢗ  
ꢗꢂꢇꢈꢁꢙꢚ  
Jꢎꢛꢚꢃ  
ꢗꢂꢇꢈꢁꢙꢚꢇ?ꢞꢂ  
NOTE: Some parts are listed and  
shown for illustration purposes  
only and are not available individu-  
ally as replacement parts.  
SKU 46750  
Page 7  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Assembly Drawing  
PLEASE READ THE FOLLOWING CAREFULLY  
THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS DIAGRAM IN THIS  
MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER NOR DISTRIBU-  
TOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE  
OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT OR THAT HE OR SHE IS  
QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT. IN FACT, THE MANUFACTURER  
AND/OR DISTRIBUTOR EXPRESSLY STATES THAT ALL REPAIRS AND PARTS REPLACEMENTS  
SHOULD BE UNDERTAKEN BY CERTIFIED AND LICENSED TECHNICIANS AND NOT BY THE  
BUYER. THE BUYER ASSUMES ALL RISK AND LIABILITY ARISING OUT OF HIS OR HER  
REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING  
OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO.  
SKU 46750  
Page 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Haier Dishwasher DW12 EBM User Manual
Hamilton Beach Slow Cooker 33957 User Manual
Harbor Freight Tools Battery Charger 91129 User Manual
Harbor Freight Tools Work Light 95388 User Manual
Heat Glo LifeStyle Outdoor Fireplace PCFM HNG User Manual
Honeywell Smoke Alarm C7015A User Manual
Humax Satellite TV System F2 Green User Manual
Humminbird Switch 531870 1_A User Manual
Hunter Fan Outdoor Ceiling Fan 43506 01 r032907 User Manual
IBM Computer Hardware 6826 User Manual