Harbor Freight Tools Metal Detector 94138 User Manual

Hand Wand  
Metal Detector  
94138  
ASSEMBLY AND OPERATING INSTRUCTIONS  
Due to continuing improvements, actual product may differ slightly from the product described herein.  
3491 Mission Oaks Blvd., Camarillo, CA 93011  
Copyright © 2006 by Harbor Freight Tools®. All rights reserved. No portion of this  
manual or any artwork contained herein may be reproduced in any shape or form  
without the express written consent of Harbor FreightTools.  
For technical questions and replacement parts, please call 1-800-444-3353  
Download from Www.Somanuals.com. All Manuals Search And Download.  
6. Maintain tools with care. Keep tools maintained and clean for better and  
safer performance. Follow instructions for maintenance and changing  
accessories.The handle must be kept clean, dry, and free from oil and grease  
at all times.  
7. Disconnect power.Turn off tool when not in use.  
8. Avoid unintentional starting. Be sure the switch is in the Off position when  
not in use and before replacing battery.  
9. Stay alert. Watch what you are doing, use common sense. Do not operate  
any tool when you are tired.  
10. Check for damaged parts. Before using this tool, any part that appears  
damaged should be carefully checked to determine that it will operate properly  
and perform its intended function. Check for any condition that may affect  
proper operation. Any part that is damaged should be properly repaired or  
replaced by a qualified technician. Do not use the wand if the switch does not  
turn On and Off properly.  
11. Guard against electric shock. Prevent body contact with grounded surfaces  
such as pipes, radiators, ranges, and refrigerator enclosures.  
12. Do not operate this tool if under the influence of alcohol or drugs. Read  
warning labels on prescriptions to determine if your judgment or reflexes are  
impaired while taking drugs. If there is any doubt, do not operate the wand.  
13. Maintenance. For your safety, service and maintenance should be performed  
regularly by a qualified technician. If the wand is to be stored for an extended  
period of time, remove the battery to prevent damage.  
14. People with pacemakers should consult their physician(s) before using this  
product. Electromagnetic fields in close proximity to a heart pacemaker could  
cause interference to or failure of the pacemaker.  
15. Harbor Freight Tools can not guarantee accuracy of this device.  
16. Check battery strength frequently, lower battery strength can affect the  
performance of this device.  
NOTE: This wand is water resistant, but not water proof. If exposed to prolonged  
rain or wet conditions, it is likely to be damaged. Protect this tool from exposure to  
water, and wipe it off immediately if it becomes wet.  
Warning:The warnings, cautions, and instructions discussed in this instruction  
manual cannot cover all possible conditions and situations that may occur. It  
must be understood by the operator that common sense and caution are factors  
which cannot be built into this product, but must be supplied by the operator.  
SKU 94138 Download from Www.SomanuPalsa.cgoem3. All Manuals Search And Download.  
Unpacking  
When unpacking, check to make sure the following parts are included.  
Hand Held Metal DetectorWand  
Carrying Case  
If any parts are missing or broken, please call Harbor Freight Tools at the number  
on the cover of this manual.  
Operation  
First install one 9 volt battery (not included).  
1. Slide open the battery compartment cover,  
located at the base of the handle.  
2. If there is an old battery in place, remove it.  
Insert one 9 volt battery (not included) into the  
battery compartment. Be sure that the polarity  
of the battery matches the correct poles  
marked “+” and “-”. If the battery is installed  
improperly, the detector can be damaged.  
3. Slide the battery compartment cover back  
in place. Be sure it is closed tight.  
The battery compartment  
NOTE: This hand wand metal detector has a  
low battery warning system.  
When the battery starts to get low, the detector will make a “chirping” sound  
instead of the normal steady tone when encountering metal. Also, the LED  
light will flash on and off rapidly when near metal. In this situation, replace the  
battery.  
NOTE: You may use rechargeable batteries with this detector (not included).  
If using rechargeable Nickle-Cadmium battery, you may use a recharging unit  
(not supplied) plugged into the recharge jack.  
WARNING: Do not attempt to recharge Alkaline or other non-rechargeable  
batteries; they may explode.  
SKU 94138 Download from Www.SomanuPalsa.cgoem4. All Manuals Search And Download.  
Basic operation of the hand wand metal detector:  
1. Slide the ON / OFF switch to the ON position to turn the detector on. Slide it  
to the OFF position to turn it OFF. When the detector is turned ON, it will  
“chirpbriefly.  
2. When not in use, turn the switch to OFF to conserve battery life.  
3. To detect metal, pass the scanner near the search area. If metal is detected,  
you will hear a high pitched tone, and the LED light will come on. The sound  
and light warnings will stop if the detector is moved away from the metal. The  
detector will emit a long tone for large objects and a short tone for small objects.  
NOTE: Before using the detector, always test it by turning it on and scanning a  
small piece of metal, such as a coin. Be sure the warning sound is a smooth,  
continuous tone, and the light shines steadily. A chirping sound and flashing  
light indicate low battery strength. Replace the battery before using.  
To adjust the detector sensitivity:  
The detector is set to optimum sensitivity for most security scanning  
purposes.You can adjust the sensitivity for other applications or as needed.  
1. Remove the rubber cover from the handle by sliding it off.You will see two  
small holes in the middle of the handle. Please refer to diagram on page 6.  
2. Insert the tip of a small, flat blade screwdriver into the 1/8” hole. Turn it slightly  
to engage the adjustment screw inside. Do not adjust the fitting in the second  
hole, which is for factory use only.  
3. Using a test object, adjust the control for the desired sensitivity.Turning the  
screw clockwise increases sensitivity.Turning the screw counterclockwise  
decreases sensitivity. While keeping the detector stationary at a specific  
distance from the test object adjust the screw until the alarm sounds. This is  
your desired sensitivity.  
4. Replace the rubber cover on the handle.  
SKU 94138 Download from Www.SomanuPalsa.cgoem5. All Manuals Search And Download.  
Using the Desensitize Button:  
1. In some cases the detector will be too sensitive.You can decrease  
sensitivity by 50% by pressing and holding the Desensitize Button.  
Charger / Earphone Jack and  
Desensitize Button  
ON / OFF switch  
SKU 94138 Download from Www.SomanuPalsa.cgoem6. All Manuals Search And Download.  
Using an earphone (not included):  
1. For quiet operation, you can use an earphone (not included) that has a 1/8”  
jack.You can hear the alarm through the earphone. Insert the earphone jack  
in the plug in shown on page 6.  
2. Using an earphone jack will silence the normal alarm sound.  
Maintenance  
1. When not in use, turn the detector OFF to save the battery.  
2. If the detector will not be used for several months, remove the battery before  
storage to prevent possible damage caused by leaking battery.  
3. Keep the detector dry. If it gets wet, wipe it off immediately.Your detector is  
not designed for use in the rain or in a wet environment.  
4. Handle the detector with care. If dropped, it can be damaged causing  
unreliable operation.  
5. Do not expose the detector to extreme temperatures.  
6. To clean the detector, wipe it with a damp cloth using clean water or mild  
detergent.  
7. Modifying or tampering with the detector or adjusting the factory adjustment  
can damage the unit.  
CAUTION: Do not open tool or attempt any repair.There are no owner  
repairable components in this tool. If repairs are needed, take this  
detector to a qualified service technician for service.  
SKU 94138 Download from Www.SomanuPalsa.cgoem7. All Manuals Search And Download.  
Schematic Diagram  
TOP SECTION  
Bottom section on page 9.  
NOTE: Replacement parts or accessories specific to this wand are not available from  
Harbor Freight Tools for this item. Replacement batteries, charger and ear jack may  
be available at your local Harbor FreightTools retail outlet, or are commonly available  
from hardware and department stores.  
SKU 94138 Download from Www.SomanuPalsa.cgoem8. All Manuals Search And Download.  
Schematic Diagram (continued)  
BOTTOM SECTION  
Top section on page 8.  
SKU 94138 Download from Www.SomanuPalsa.cgoem9. All Manuals Search And Download.  
WARRANTY CARD  
LIMITED 1 YEAR  
WARRANTY  
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and  
durability standards, and warrants to the original purchaser that this product is free from defects in  
materials and workmanship for the period of one year from the date of purchase. This warranty  
does not apply to damage due directly or indirectly to misuse, abuse, negligence or accidents;  
repairs or alterations outside our facilities; or to lack of maintenance. We shall in no event be liable  
for death, injuries to persons or property, or for incidental, contingent, special or consequential  
damages arising from the use of our product. Some states do not allow the exclusion or limitation  
of incidental or consequential damages, so the above limitation of exclusion may not apply to you.  
To take advantage of this warranty, the product or part must be returned to us with transportation  
charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the  
merchandise. If our inspection verifies the defect, we will either repair or replace the product at our  
election or we may elect to refund the purchase price if we cannot readily and quickly provide you  
with a replacement. We will return repaired products at our expense, but if we determine there is no  
defect, or that the defect resulted from causes not within the scope of our warranty, then you must  
bear the cost of returning the product.  
This warranty gives you specific legal rights and you may also have other rights which vary from  
state to state.  
3491 Mission Oaks Blvd.  
P.O. Box 6009  
Camarillo, CA 93011  
(800) 444-3353  
SKU 94138 Download from Www.SomanuPalsa.cgoem1. A0ll Manuals Search And Download.  

Grizzly Sander G9979 User Manual
Haier Air Conditioner AD182AMEAA User Manual
Harbor Freight Tools Scale 95364 User Manual
Hasbro Motorized Toy Car 85660 User Manual
Hayter Mowers Lawn Mower 15 40 User Manual
Hotpoint Clothes Dryer Aquarius+ User Manual
HP Hewlett Packard Scanner 3400Cse User Manual
HP Hewlett Packard Server 409513 B21 User Manual
IBM Printer LA75P User Manual
IDEAL INDUSTRIES Range BUC5034 User Manual