Hand Wand
Metal Detector
94138
ASSEMBLY AND OPERATING INSTRUCTIONS
Due to continuing improvements, actual product may differ slightly from the product described herein.
3491 Mission Oaks Blvd., Camarillo, CA 93011
Copyright © 2006 by Harbor Freight Tools®. All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor FreightTools.
For technical questions and replacement parts, please call 1-800-444-3353
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Maintain tools with care. Keep tools maintained and clean for better and
safer performance. Follow instructions for maintenance and changing
accessories.The handle must be kept clean, dry, and free from oil and grease
at all times.
7. Disconnect power.Turn off tool when not in use.
8. Avoid unintentional starting. Be sure the switch is in the Off position when
not in use and before replacing battery.
9. Stay alert. Watch what you are doing, use common sense. Do not operate
any tool when you are tired.
10. Check for damaged parts. Before using this tool, any part that appears
damaged should be carefully checked to determine that it will operate properly
and perform its intended function. Check for any condition that may affect
proper operation. Any part that is damaged should be properly repaired or
replaced by a qualified technician. Do not use the wand if the switch does not
turn On and Off properly.
11. Guard against electric shock. Prevent body contact with grounded surfaces
such as pipes, radiators, ranges, and refrigerator enclosures.
12. Do not operate this tool if under the influence of alcohol or drugs. Read
warning labels on prescriptions to determine if your judgment or reflexes are
impaired while taking drugs. If there is any doubt, do not operate the wand.
13. Maintenance. For your safety, service and maintenance should be performed
regularly by a qualified technician. If the wand is to be stored for an extended
period of time, remove the battery to prevent damage.
14. People with pacemakers should consult their physician(s) before using this
product. Electromagnetic fields in close proximity to a heart pacemaker could
cause interference to or failure of the pacemaker.
15. Harbor Freight Tools can not guarantee accuracy of this device.
16. Check battery strength frequently, lower battery strength can affect the
performance of this device.
NOTE: This wand is water resistant, but not water proof. If exposed to prolonged
rain or wet conditions, it is likely to be damaged. Protect this tool from exposure to
water, and wipe it off immediately if it becomes wet.
Warning:The warnings, cautions, and instructions discussed in this instruction
manual cannot cover all possible conditions and situations that may occur. It
must be understood by the operator that common sense and caution are factors
which cannot be built into this product, but must be supplied by the operator.
SKU 94138 Download from Www.SomanuPalsa.cgoem3. All Manuals Search And Download.
Unpacking
When unpacking, check to make sure the following parts are included.
Hand Held Metal DetectorWand
Carrying Case
If any parts are missing or broken, please call Harbor Freight Tools at the number
on the cover of this manual.
Operation
First install one 9 volt battery (not included).
1. Slide open the battery compartment cover,
located at the base of the handle.
2. If there is an old battery in place, remove it.
Insert one 9 volt battery (not included) into the
battery compartment. Be sure that the polarity
of the battery matches the correct poles
marked “+” and “-”. If the battery is installed
improperly, the detector can be damaged.
3. Slide the battery compartment cover back
in place. Be sure it is closed tight.
The battery compartment
NOTE: This hand wand metal detector has a
low battery warning system.
When the battery starts to get low, the detector will make a “chirping” sound
instead of the normal steady tone when encountering metal. Also, the LED
light will flash on and off rapidly when near metal. In this situation, replace the
battery.
NOTE: You may use rechargeable batteries with this detector (not included).
If using rechargeable Nickle-Cadmium battery, you may use a recharging unit
(not supplied) plugged into the recharge jack.
WARNING: Do not attempt to recharge Alkaline or other non-rechargeable
batteries; they may explode.
SKU 94138 Download from Www.SomanuPalsa.cgoem4. All Manuals Search And Download.
Basic operation of the hand wand metal detector:
1. Slide the ON / OFF switch to the ON position to turn the detector on. Slide it
to the OFF position to turn it OFF. When the detector is turned ON, it will
“chirp”briefly.
2. When not in use, turn the switch to OFF to conserve battery life.
3. To detect metal, pass the scanner near the search area. If metal is detected,
you will hear a high pitched tone, and the LED light will come on. The sound
and light warnings will stop if the detector is moved away from the metal. The
detector will emit a long tone for large objects and a short tone for small objects.
NOTE: Before using the detector, always test it by turning it on and scanning a
small piece of metal, such as a coin. Be sure the warning sound is a smooth,
continuous tone, and the light shines steadily. A chirping sound and flashing
light indicate low battery strength. Replace the battery before using.
To adjust the detector sensitivity:
The detector is set to optimum sensitivity for most security scanning
purposes.You can adjust the sensitivity for other applications or as needed.
1. Remove the rubber cover from the handle by sliding it off.You will see two
small holes in the middle of the handle. Please refer to diagram on page 6.
2. Insert the tip of a small, flat blade screwdriver into the 1/8” hole. Turn it slightly
to engage the adjustment screw inside. Do not adjust the fitting in the second
hole, which is for factory use only.
3. Using a test object, adjust the control for the desired sensitivity.Turning the
screw clockwise increases sensitivity.Turning the screw counterclockwise
decreases sensitivity. While keeping the detector stationary at a specific
distance from the test object adjust the screw until the alarm sounds. This is
your desired sensitivity.
4. Replace the rubber cover on the handle.
SKU 94138 Download from Www.SomanuPalsa.cgoem5. All Manuals Search And Download.
Using the Desensitize Button:
1. In some cases the detector will be too sensitive.You can decrease
sensitivity by 50% by pressing and holding the Desensitize Button.
Charger / Earphone Jack and
Desensitize Button
ON / OFF switch
SKU 94138 Download from Www.SomanuPalsa.cgoem6. All Manuals Search And Download.
Using an earphone (not included):
1. For quiet operation, you can use an earphone (not included) that has a 1/8”
jack.You can hear the alarm through the earphone. Insert the earphone jack
in the plug in shown on page 6.
2. Using an earphone jack will silence the normal alarm sound.
Maintenance
1. When not in use, turn the detector OFF to save the battery.
2. If the detector will not be used for several months, remove the battery before
storage to prevent possible damage caused by leaking battery.
3. Keep the detector dry. If it gets wet, wipe it off immediately.Your detector is
not designed for use in the rain or in a wet environment.
4. Handle the detector with care. If dropped, it can be damaged causing
unreliable operation.
5. Do not expose the detector to extreme temperatures.
6. To clean the detector, wipe it with a damp cloth using clean water or mild
detergent.
7. Modifying or tampering with the detector or adjusting the factory adjustment
can damage the unit.
CAUTION: Do not open tool or attempt any repair.There are no owner
repairable components in this tool. If repairs are needed, take this
detector to a qualified service technician for service.
SKU 94138 Download from Www.SomanuPalsa.cgoem7. All Manuals Search And Download.
Schematic Diagram
TOP SECTION
Bottom section on page 9.
NOTE: Replacement parts or accessories specific to this wand are not available from
Harbor Freight Tools for this item. Replacement batteries, charger and ear jack may
be available at your local Harbor FreightTools retail outlet, or are commonly available
from hardware and department stores.
SKU 94138 Download from Www.SomanuPalsa.cgoem8. All Manuals Search And Download.
Schematic Diagram (continued)
BOTTOM SECTION
Top section on page 8.
SKU 94138 Download from Www.SomanuPalsa.cgoem9. All Manuals Search And Download.
WARRANTY CARD
LIMITED 1 YEAR
WARRANTY
Harbor Freight Tools Co. makes every effort to assure that its products meet high quality and
durability standards, and warrants to the original purchaser that this product is free from defects in
materials and workmanship for the period of one year from the date of purchase. This warranty
does not apply to damage due directly or indirectly to misuse, abuse, negligence or accidents;
repairs or alterations outside our facilities; or to lack of maintenance. We shall in no event be liable
for death, injuries to persons or property, or for incidental, contingent, special or consequential
damages arising from the use of our product. Some states do not allow the exclusion or limitation
of incidental or consequential damages, so the above limitation of exclusion may not apply to you.
To take advantage of this warranty, the product or part must be returned to us with transportation
charges prepaid. Proof of purchase date and an explanation of the complaint must accompany the
merchandise. If our inspection verifies the defect, we will either repair or replace the product at our
election or we may elect to refund the purchase price if we cannot readily and quickly provide you
with a replacement. We will return repaired products at our expense, but if we determine there is no
defect, or that the defect resulted from causes not within the scope of our warranty, then you must
bear the cost of returning the product.
This warranty gives you specific legal rights and you may also have other rights which vary from
state to state.
3491 Mission Oaks Blvd.
•
P.O. Box 6009
•
Camarillo, CA 93011
•
(800) 444-3353
SKU 94138 Download from Www.SomanuPalsa.cgoem1. A0ll Manuals Search And Download.
|