Statement of Agency Compliance
This device complies with part 15 of the FCC Rules. Operation is subject to the
following two conditions: (1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that
may cause undesired operation.
FCC Class B Compliance Statement
This equipment has been tested and found to comply with the limits for a Class
B digital device pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential
installation. This equipment generates, uses, and can radiate radio frequency
energy and, if not installed and used in accordance with the instructions, may
cause harmful interference to radio communications. However, there is no
guarantee that interference will not occur in a particular installation. If this
equipment does cause harmful interference to radio or television reception,
which can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one or more of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
• Consult the dealer or an experienced radio or television technician for
help.
Caution: Any changes or modifications made to this device that are not
expressly approved by Hand Held Products may void the user’s authority to
operate the equipment.
Note: To maintain compliance with FCC Rules and Regulations, cables
connected to this device must be shielded cables, in which the cable shield
wire(s) have been grounded (tied) to the connector shell.
Canadian Notice
This equipment does not exceed the Class B limits for radio noise emissions as
described in the Radio Interference Regulations of the Canadian Department of
Communications.
Le present appareil numerique n’emet pas de bruits radioelectriques depassant
les limites applicables aux appareils numeriques de la classe B prescrites dans
le Reglement sur le brouillage radioelectrique edicte par le ministere des
Communications du Canada.
Download from Www.Somanuals.com. All Manuals Search And Download.
The CE mark on the product indicates that the system has been
tested to and conforms with the provisions noted within the 89/336/
EEC Electromagnetic Compatibility Directive and the 73/23/EEC
Low Voltage Directive.
For CE-related inquiries, please contact:
Hand Held Products
Nijverheidsweg 9
5627 BT Eindhoven
The Netherlands
Hand Held Products shall not be liable for use of our product with equipment (i.e.,
power supplies, personal computers, etc.) that is not CE marked and does not
comply with the Low Voltage Directive.
UL and cUL Statement
UL listed UL1950 and CSA 22.2 No.950. cUL listed UL1950 and CSA 22.2 No
950.
LED Safety Statement
This device has been tested in accordance with EN60825-1 LED safety, and has
been certified to be under the limits of a Class 1 LED device.
Aimer Beam Safety Statement (IT5800 Option only)
This device has been tested in accordance with and complies
with EN60825-1: 1994+A11+A2 and 21 CFR 1040.10 and
1040.11, except for deviations pursuant to Laser Notice No.
50, dated July 26, 2001.
LASER LIGHT, DO NOT STARE INTO BEAM, CLASS 2 LASER PRODUCT,
1.0 mW MAX OUTPUT: 650nM.
Caution: Use of controls or adjustments or performance of procedures
other than those specified herein may result in hazardous
radiation exposure.
TÜV Statement
TÜV or GS marked to EN60950 and EN60825-1.
C-Tick Statement
Conforms to AS/NZS 3548. C-Tick number: N10410.
Download from Www.Somanuals.com. All Manuals Search And Download.
Mexico
Patents
Certified
Please refer to the IT5600/5800 packaging for patent information.
Solids and Water Protection
The IT5600 has a rating of IP41, immunity of foreign particles and dripping water.
The IT5800 has a rating of IP54, immunity of windblown dust penetration and
splashing water.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
IT5600/5800 ......................................................................... 1-1
IBM 4683 Ports 5B, 9B, and 17 Interface...................... 1-8
IBM SurePos................................................................ 1-10
Chapter 2 - Terminal Interfaces
Terminal ID .......................................................................... 2-1
Supported Terminals............................................................. 2-2
Keyboard Country ................................................................ 2-4
Keyboard Style ..................................................................... 2-5
Keyboard Modifiers.............................................................. 2-6
i
Download from Www.Somanuals.com. All Manuals Search And Download.
Wand Emulation Transmission Rate............................ 2-12
Wand Emulation Idle ................................................... 2-13
Chapter 3 - Output
Hands Free Time-Out ........................................................... 3-5
Reread Delay ........................................................................ 3-5
User-Specified Reread Delay......................................... 3-6
Aimer Beam Delay (Aimer Beam option only).................... 3-7
User-Specified Aimer Beam Delay................................ 3-7
Aimer Mode (Aimer Beam option only) .............................. 3-7
Aimer Beam Time-Out (Aimer Beam option only) ............. 3-8
Centering Window................................................................ 3-8
ii
Download from Www.Somanuals.com. All Manuals Search And Download.
Output Sequence Editor................................................ 3-11
Suffix Selections............................................................. 4-4
Intercharacter, Interfunction, and Intermessage Delays ....... 4-4
Data Format Editor Introduction........................................... 5-1
Other Programming Selections ...................................... 5-2
Chapter 6 - Secondary Interface
IT5600 Models...................................................................... 6-1
IT5800 Models...................................................................... 6-1
Enabling the Secondary Interface ......................................... 6-1
Secondary RS-232 Connection............................................. 6-2
iii
Download from Www.Somanuals.com. All Manuals Search And Download.
Secondary Code 39 Wand Emulation................................... 6-2
Laser Emulation Transmission Rate..................................... 6-3
Code 93 Message Length............................................. 7-11
Code 93 Code Page...................................................... 7-11
Code 2 of 5.......................................................................... 7-12
Code 2 of 5 Message Length........................................ 7-12
IATA Code 2 of 5 Message Length............................. 7-13
Matrix 2 of 5....................................................................... 7-13
Matrix 2 of 5 Message Length ..................................... 7-14
iv
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN 13 Addenda Separator................................. 7-25
ISBN Translate............................................................. 7-25
EAN/JAN 8......................................................................... 7-26
EAN/JAN 8 Check Digit.............................................. 7-26
EAN/JAN 8 Addenda................................................... 7-26
EAN/JAN 8 Addenda Required ................................... 7-27
EAN/JAN 8 Addenda Separator................................... 7-27
v
Download from Www.Somanuals.com. All Manuals Search And Download.
PosiCode Message Length........................................... 7-34
Codablock F Message Length...................................... 7-35
Code 49............................................................................... 7-37
Code 49 Message Length............................................. 7-37
Chapter 9 - Utilities
To Add a Test Code I.D. Prefix to All Symbologies............ 9-1
Resetting the Standard Product Defaults.............................. 9-1
Temporary Visual Menu 2003 Configuration ...................... 9-2
Chapter 10 - Visual Menu 2003
Visual Menu 2003 Introduction.......................................... 10-1
Installing Visual Menu 2003 from the Web................. 10-1
vi
Download from Www.Somanuals.com. All Manuals Search And Download.
Query Commands......................................................... 11-2
Responses ..................................................................... 11-2
Chapter 12 - Product Specifications
IT5600 Product Specifications............................................ 12-1
Maintenance........................................................................ 13-1
Chapter 14 - Customer Support
Product Service and Repair................................................. 14-1
Online Product Service and Repair Assistance ............ 14-2
Technical Assistance........................................................... 14-2
Online Technical Assistance ........................................ 14-2
Limited Warranty................................................................ 14-2
vii
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A - Appendix A
Symbology Chart..................................................................A-1
ASCII Conversion Chart (Code Page 1252).........................A-2
Code Page Mapping of Printed Bar Codes...........................A-4
viii
Download from Www.Somanuals.com. All Manuals Search And Download.
1
Getting Started
IT5600/5800
The IT5600 and IT5800 mark a new performance level for handheld scanners.
Both the IT5600 and IT5800 are powered by Hand Held Products AdaptusTM
Imaging Technology. The performance of Adaptus technology delivers
aggressive read rates and depths of field on 1D, stacked linear, and matrix
codes.
Designed for today’s demanding retail and commercial environments, the
IT5600 offers a superior reading range, durability, and the ability to read poor
quality bar codes. Linear imaging technology is defined by a bright and sharply
focused aiming line, high resolution imaging, and fast reading speed. The
IT5600 is comfortable to hold, easy to use, rugged, and excellent for retail
applications, as well as for all general scanning applications.
The IT5800 handheld industrial image reader is the first industrial class reader to
be powered by Hand Held Products Adaptus imaging technology. Adaptus
technology allows you to read bar codes at ranges up to 82 inches on paper
labels. In addition, this technology allows your IT5800 to pick up and process
your bar code image 270 times per second. Although the IT5800 uses the same
general ergonomic design as the IT5600, the IT5800 is built to withstand your
toughest industrial applications.
About This Manual
This User’s Guide provides installation and programming instructions for the
IT5600/5800. Product specifications, dimensions, warranty, and customer
support information are also included.
Hand Held Products bar code scanners are factory programmed for the most
common terminal and communications settings. If you need to change these
settings, programming is accomplished by scanning the bar codes in this guide.
An asterisk (*) next to an option indicates the default setting.
Unpacking the Scanner
After you open the shipping carton containing the IT5600/5800, take the
following steps:
•
•
•
Check to make sure everything you ordered is present.
Check for damage during shipment. Report damage immediately to the
carrier who delivered the carton.
IT5600/IT5800 User’s Guide
1 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
IT5600 Models
Note: The Hand Held Products IT5600 scanner may be used with many
interfaces, which are described in this user’s guide. Refer to the chart
below to determine the models that can be used with the interface you are
using. Refer to Chapter 6 for programming information regarding
Secondary Interfaces.
The chart below lists the IT5600 scanner models. “SR” indicates “Standard
Range” linear optics.
Secondary
Interfaces
Models
Primary Interfaces
5600SRX00
5600SR030
TTL Level 232
Laser Emulation
True RS-232
True RS-232, True RS-232
serial wedge
5600SRX50
Keyboard wedge, TTL level
232, TTL level 232 serial
Wand Emulation, TTL
level 232
wedge, IBM 4683, wand emula-
tion, USB keyboard, USB HID,
USB retail (IBM SurePOS)
IT5800 Models
Note: The Hand Held Products IT5800 scanner may be used with many
interfaces, which are described in this user’s guide. Refer to the chart
below to determine the models that can be used with the interface you are
using. Refer to Chapter 6 for programming information regarding
Secondary Interfaces.
The chart below lists the IT5800 scanner models. “SR” indicates “Standard
Range” linear optics. If the product number has the number one (1) as the last
character, the unit contains the aimer beam option (e.g., 5800SR001).
Secondary
Interfaces
Models
Primary Interfaces
5800SR00X
5800SR03X
TTL Level 232
Laser Emulation
True RS-232
True RS-232, True RS-232
serial wedge
1 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Secondary
Interfaces
Models
Primary Interfaces
5800SR05X
Keyboard wedge, TTL level
232, TTL level 232 serial
Wand Emulation, TTL
level 232
wedge, IBM 4683, wand emula-
tion, USB keyboard, USB HID,
USB retail (IBM SurePOS)
IT5600/5800 Scanner Identification
IT5600/IT5800 User’s Guide
1 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Scanner When Powered by Host
(Keyboard Wedge)
A scanner can be connected between the keyboard and PC as a “keyboard
wedge,” plugged into the serial port, or connected to a portable data terminal in
wand emulation or non decoded output mode. The following is an example of a
keyboard wedge connection:
1. Turn off power to the terminal/computer.
2. Disconnect the keyboard cable
from the back of the terminal/
computer.
Disconnect
3. Connect the
appropriate
interface
3
cable to the
scanner and
to the
terminal/
computer.
2
1
4. Turn the terminal/computer power back on. The scanner beeps.
5. Verify the scanner operation by scanning a bar code from the Sample
Symbols in the back of this manual. The scanner beeps once.
IT5600/IT5800 User’s Guide
1 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Reading Techniques
The scanner has a view finder that projects a bright red aiming beam that
corresponds to its horizontal field of view. The aiming line should be centered
horizontally over the bar code; it will not read if the aiming line is in any other
direction.
Good Read
Bad Read
Bad Read
The best focus point for reading most code densities is about 5 inches (12.7 cm)
from the unit. To read single or multiple symbols (on a page or on an object),
hold the imager at an appropriate distance from the target, pull the trigger, and
center the aiming line on the symbol.
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your scanner, or you’ve
changed some options and want the factory settings restored, scan the
Standard Product Default Settings bar code below.
Standard Product Default Settings
The Menu Commands starting on page 11-5 lists the factory default settings for
each of the commands (indicated by an asterisk (*) on the programming pages).
Plug and Play
Plug and Play bar codes provide instant scanner set up for commonly used
interfaces.
1 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: After you scan one of the codes, power cycle the host terminal to have the
interface in effect.
Keyboard Wedge Connection
IT5600 scanners are factory programmed for a keyboard wedge interface to an
IBM PC AT with a USA keyboard. If this is your interface and you do not need to
modify the settings, skip to Chapter 3 - Output.
If you programmed the scanner for a different terminal interface and you want to
change to an IBM PC AT and compatibles keyboard wedge interface, scan the
bar code below.
Note: The following bar code also programs a carriage return (CR) suffix.
IBM PC AT and Compatibles
with CR suffix
Laptop Direct Connect
For most laptops, scanning the Laptop Direct Connect bar code allows
operation of the scanner in parallel with the integral keyboard. The following
Laptop Direct Connect bar code selects terminal ID 03, programs a carriage
return (CR) suffix and turns on Emulate External Keyboard (page 2-5).
Laptop Direct Connect
with CR suffix
RS-232
The RS-232 Interface bar code is used when connecting to the serial port of a
PC or terminal. The following RS-232 Interface bar code also programs a
carriage return (CR) and a line feed (LF) suffix, baud rate, and data format as
indicated below. It also changes the trigger mode to manual.
Option
Setting
Baud Rate
Data Format
38400 bps
8 data bits, no parity bit, 1 stop bit
RS-232 Interface
IT5600/IT5800 User’s Guide
1 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Wand Emulation Plug & Play
In Wand Emulation mode, the imager decodes the bar code then sends data in
symbologies to Code 39.
The Same Code Format transmits UPC, EAN, Code 128 and Interleaved 2 of 5
without any changes, but converts all other symbologies to Code 39.
The Wand Emulation Plug & Play Code 39 Format bar code below sets the
terminal ID to 61. The Wand Emulation Plug & Play Same Code Format bar
code sets the terminal ID to 64. These Plug & Play bar codes also set the
Transmission Rate to 25 inches per second, Output Polarity to black high, and
Idle State to high. (If you want to change the terminal ID only, without changing
any other imager settings, please refer to Wand Emulation Connection on page
2-11.)
Wand Emulation (Code 39 Format)
Wand Emulation Same Code
IBM 4683 Ports 5B, 9B, and 17 Interface
Scan one of the following “Plug and Play” codes to program the 56/5800SR050
for IBM 4683 Port 5B, 9B, or 17.
Note: After scanning one of these codes, you must power cycle the cash
register.
IBM 4683 Port 5B Interface
IBM 4683 Port 9B HHBCR-1 Interface
IBM 4683 Port 9B HHBCR-2 Interface
IBM 4683 Port 17 Interface
1 - 8
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Each bar code above also programs the following suffixes for each symbology:
Symbology
EAN 8
Suffix
0C
EAN 13
16
UPC A
0D
UPC E
0A
Code 39
00 0A 0B
00 0D 0B
00 0A 0B
00 18 0B
Interleaved 2 of 5
Code 128 *
Code 128 **
* Suffixes programmed for Code 128 with IBM 4683 Port 5B, IBM 4683 Port 9B HHBCR-1,
and IBM 4683 Port 17 Interfaces
**Suffixes programmed for Code 128 with IBM 4683 Port 9 HHBCR-2 Interface
IT5600/IT5800 User’s Guide
1 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Scanner with USB
A scanner can be connected to the USB port of a computer.
1. Connect the appropriate interface cable to the scanner and to the computer.
2. The scanner beeps.
3. Verify the scanner operation by scanning a bar code from the Sample
Symbols in the back of this manual.
Note: The following USB “Plug and Play” codes are supported on specific
IT5600 and IT5800 models. Refer to IT5600 Models and IT5800
Models on page 1-2 to determine if this interface applies to your scanner.
IBM SurePos
Scan one of the following “Plug and Play” codes to program the IT5600/5800 for
IBM SurePos (USB Handheld scanner) or IBM SurePos (USB Tabletop
scanner).
1 - 10
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: After scanning one of these codes, you must power cycle the cash
register.
IBM SurePos (USB Handheld Scanner) Interface
IBM SurePos (USB Tabletop Scanner) Interface
Each bar code above also programs the following suffixes for each symbology:
Symbology
EAN 8
Suffix
0C
EAN 13
16
UPC A
0D
UPC E
0A
Code 39
Interleaved 2 of 5
Code 128
00 0A 0B
00 0D 0B
00 18 0B
USB PC or Macintosh Keyboard
Scan one of the following codes to program the IT5600/5800 for USB PC
Keyboard or USB Macintosh Keyboard. Scanning these codes adds a CR and
selects the terminal ID (USB PC Keyboard - 124, USB Macintosh Keyboard -
125).
USB Keyboard (PC)
USB Keyboard (Mac)
USB HID
Scan the following code to program the IT5600/5800 for USB HID bar code
USB HID Bar Code Scanner
IT5600/IT5800 User’s Guide
1 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
USB Com Port Emulation
The driver will use the next available Com Port number. Apple® Macintosh
computers recognize the imager as a USB CDC class device and automatically
uses a class driver. Scanning the code below changes the terminal ID to 130.
USB Com Port Emulation
Note: No extra configuration (e.g., baud rate) is necessary.
CTS/RTS Emulation
On
* Off
ACK/NAK Mode
On
* Off
Connecting the Scanner with Serial Wedge
The IT5600/5800 uses True and TTL signal levels to wedge into an RS-232 serial
network. Use only IT5600/5800 serial wedge cables to prevent damage to the
scanner. Refer to Connecting the Scanner with RS-232 Serial Port on page 2-8
to set the baud rate and communications protocol.
1. Turn off power to the computer.
2. Disconnect the existing serial cable from the computer.
3. Connect the appropriate interface cable to the scanner.
1 - 12
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: For the scanner to work properly, you must have the correct cable for your
type of computer.
To Host
5
4
3
6
4. Plug the serial connector into the serial port on your computer. Tighten the
two screws to secure the connector to the port.
screws.
6. Plug the power pack cable into the receptor on the scanner cable.
7. Plug the power pack into a power source.
8. Once the scanner has been fully connected, power up the computer.
To set up the serial wedge terminal ID, use the serial terminal ID 050 and follow
the instructions on page 2-1. Set the port to which you want the scanned data to
transmit. Port 1 corresponds to P1 on the output cable and Port 2 corresponds
to P2 on the output cable. Choosing Both sends scanned data to P1 and P2.
Default = P1.
* P1
P2
IT5600/IT5800 User’s Guide
1 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
1 - 14
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
2
Terminal ID
If your interface is not a standard PC AT, refer to "Supported Terminals" on
page 2-2 through page 2-3, and locate the Terminal ID number for your PC.
Scan the Terminal ID bar code below, then scan the numeric bar code(s) from
the Programming Chart inside the back cover of this manual to program the
scanner for your terminal ID. Scan Save to save your selection.
For example, an IBM AT terminal has a Terminal ID of 003. You would scan the
Terminal ID bar code, then 0, 0, 3 from the Programming Chart inside the back
cover of this manual, then Save. If you make an error while scanning the digits
(before scanning Save), scan the Discard code on the Programming Chart, scan
the Terminal ID bar code, scan the digits, and the Save code again.
Terminal ID
Save
Note: After scanning one of these codes, you must power cycle your computer.
IT5600/IT5800 User’s Guide
2 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Terminals
Terminal
Model(s)
Terminal ID
DEC
DEC
VT510, 520, 525 (PC style)
VT510, 520, 525 (DEC style
LK411)
005
104
Esprit
Heath Zenith
HP
IBM
IBM
200, 400
PC, AT
Vectra
005
003
003
001
002
003 *
XT
PS/2 25, 30, 77DX2
AT, PS/2 30–286, 50, 55SX, 60,
70, 70–061, 70–121, 80
IBM
IBM 102 key
3151, 3161, 3162, 3163, 3191,
3192, 3194, 3196, 3197, 3471,
3472, 3476, 3477
006
IBM 122 key
IBM 122 key
3191, 3192, 3471, 3472
3196, 3197, 3476, 3477, 3486,
3482, 3488
007
008
IBM 122 key
IBM 122 key
IBM DOS/V 106 key
IBM SurePOS
IBM SurePOS
IBM Thinkpad
IBM Thinkpad
IBM Thinkpad
I/O 122 key
ITT
3180
024
114
102
128***
129***
097
106
003
008
007
007
103
001
003
3180 data entry keyboard
PC & Workstation
USB Handheld Scanner
USB Tabletop Scanner
360 CSE, 340, 750
365, 755CV
2676D, 2677C, 2677D
9271
Lee Data
NEC
Olivetti
Olivetti
IIS
98XX Series
M19, M200
M240, M250, M290, M380,
P500
RS-232 True
RS-232 TTL
Serial Wedge
Silicon Graphics
Telex 88 key
000**
000
050
005
025
Indy, Indigoll
078, 078A, 79, 80, 191, 196,
1191,1192, 1471, 1472, 1476,
1477, 1483
Telex 88 key
Telex 102 key
Data Entry Keyboard
112
045
078, 078A, 79, 80, 191, 196,
1191,1192, 1471, 1472, 1476,
1477, 1483
2 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Terminals (Continued)
Terminal
Model(s)
Terminal ID
Telex 122 key
078, 078A, 79, 80, 191, 196,
1191,1192, 1471, 1472, 1476,
1477, 1482, 1483
046
USB PC Keyboard
USB Mac Keyboard
USB Com Port
124***
125***
130
USB HIDPOS
Wand Emulation (Code
39 Format)
131***
061
Wand Emulation (Same
Code Format)
064
* Default for 5600SR010 and 56/5800SR050 models
** Default for 5600SR030 model (applies to 5600SR030 models only)
***Applies to 56/5800SR050 model only. It is best to use the Plug and Play bar codes on
page 1-11 to program these interfaces, rather than scanning the terminal ID listed in this
table.
IT5600/IT5800 User’s Guide
2 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Keyboard Country
Scan the appropriate country code below to program the keyboard for your
country. As a general rule, the following characters are supported, but need
special care for countries other than the United States:
@ | $ # { } [ ] = / ‘ \ < > ~
* United States
Belgium
Denmark
Finland
France
Germany/Austria
Great Britain
Italy
Norway
Spain
Switzerland
2 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
keyboard country support information and applicable interfaces. If you need to
program a keyboard for a country other than one listed above, scan the Program
Keyboard Country bar code below, then scan the numeric bar code(s) for the
appropriate country from the inside back cover, then the Save bar code.
Program Keyboard Country
Keyboard Style
This programs keyboard styles, such as Caps Lock and Shift Lock. Default =
Regular.
Regular is used when you normally have the Caps Lock key off.
* Regular
Caps Lock is used when you normally have the Caps Lock key on.
Caps Lock
Shift Lock is used when you normally have the Shift Lock key on (not common
to U.S. keyboards).
Shift Lock
Automatic Caps Lock is used if you change the Caps Lock key on and off. The
software tracks and reflects if you have Caps Lock on or off (AT and PS/2 only).
This selection can only be used with systems that have an LED which notes the
Caps Lock status.
Automatic Caps Lock
Autocaps via NumLock bar code should be scanned in countries (e.g.,
Germany, France) where the Caps Lock key cannot be used to toggle Caps
Lock. The NumLock option works similarly to the regular Auotcaps, but uses the
NumLock key to retrieve the current state of the Caps Lock.
Autocaps via NumLock
IT5600/IT5800 User’s Guide
2 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Emulate External Keyboard should be scanned if you do not have an external
keyboard (IBM AT or equivalent).
Emulate External Keyboard
Note: After scanning the Emulate External Keyboard bar code, you must power
cycle your computer.
Keyboard Modifiers
This modifies special keyboard features, such as CTRL+ ASCII codes and Turbo
Mode.
Control + ASCII Mode On: The scanner sends key combinations for ASCII
control characters for values 00-1F. Refer to Keyboard Function
Relationships, page 8-1 for CTRL+ ASCII Values. Default = Off
Control + ASCII Mode On
* Control + ASCII Mode Off
Turbo Mode: The scanner sends characters to a terminal faster. If the terminal
drops characters, do not use Turbo Mode. Default = Off
Turbo Mode On
* Turbo Mode Off
Numeric Keypad Mode: Sends numeric characters as if entered from a
numeric keypad. Default = Off
Numeric Keypad Mode On
* Numeric Keypad Mode Off
2 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Automatic Direct Connect Mode: This selection can be used if you have an
IBM AT style terminal and the system is dropping characters. Default = Off
Automatic Direct
Connect Mode On
* Automatic Direct Connect
Mode Off
IT5600/IT5800 User’s Guide
2 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Connecting the Scanner with RS-232 Serial Port
Note: These instructions are for use with the RS-232 power stealer cable.
1. Turn off power to the terminal/computer.
2. Connect the appropriate interface cable to the scanner.
Note: For the scanner to work properly, you must have the correct cable for your
type of terminal/computer.
5
2
4
3
3. Unplug the mouse or keyboard from the computer. Plug the mouse or
keyboard into the power tap on the scanner cable.
4. Plug the power tap into the mouse or keyboard port.
5. Plug the serial connector into the serial port on your computer. Tighten the
two screws to secure the connector to the port.
6. Once the scanner has been fully connected, power up the computer.
All communication parameters between the scanner and terminal must match for
correct data transfer through the serial port using RS-232 protocol. Scanning the
RS-232 interface bar code, programs the scanner for an RS-232 interface at
38,400 baud, parity–none, 8 data bits, 1 stop bit, and adds a suffix of a CR LF.
RS-232 Interface
2 - 8
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 Baud Rate
Baud Rate sends the data from the scanner to the terminal at the specified rate.
The host terminal must be set for the same baud rate as the scanner.
Default = 115,200.
300
600
1200
2400
4800
9600
19200
38400
57,600
* 115,200
IT5600/IT5800 User’s Guide
2 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 Word Length: Data Bits, Stop Bits, and Parity
Data Bits sets the word length at 7 or 8 bits of data per character. If an
application requires only ASCII Hex characters 0 through 7F decimal (text, digits,
and punctuation), select 7 data bits. For applications which require use of the full
ASCII set, select 8 data bits per character. Default = 8.
Stop Bits sets the stop bits at 1 or 2. Default = 1.
Parity provides a means of checking character bit patterns for validity.
Default = None.
7 Data, 1 Stop, Parity Even
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop Parity None
7 Data, 2 Stop, Parity Odd
8 Data, 1 Stop, Parity Even
* 8 Data, 1 Stop, Parity None
8 Data, 1 Stop, Parity Odd
2 - 10
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
RS-232 Handshaking
RS-232 handshaking is a set of rules concerning the exchange of data between
serially communicating devices. Default = RTS/CTS, XON/XOFF and ACK/
NAK Off
RTS/CTS On
* RTS/CTS Off
XON/XOFF On
* XON/OFF Off
ACK/NAK On
Wand Emulation Connection
The Wand Emulation Connection bar codes should be used if you want to
change the terminal ID only, without changing any other imager settings. We
recommend using Wand Emulation Plug & Play bar codes to program your
imager to emulate a wand reader. The Wand Emulation Plug & Play bar codes
change other parameters, in addition to changing the terminal ID. Please refer
to Wand Emulation Plug & Play on page 1-8 for further information.
In Wand Emulation mode, the imager decodes the bar code then sends data in
the same format as a wand imager. The Code 39 Format converts all
symbologies to Code 39.
The Same Code Format transmits UPC, EAN, Code 128 and Interleaved 2 of 5
without any changes, but converts all other symbologies to Code 39. 2D
symbologies are converted to Code 128.
The Code 39 Format bar code below sets the terminal ID to 61, and the Same
Code Format bar code sets the terminal ID to 64.
Code 39 Format
Same Code Format
IT5600/IT5800 User’s Guide
2 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Wand Emulation Transmission Rate
The transmission rate is limited by the terminal’s ability to receive data without
dropping characters. Default = 25 inches/second.
10
* 25
40
80
120
150
200
Wand Emulation Polarity
The Polarity can be sent as standard with black bars high, or reversed with white
bars high. Default = Black High.
* Black High
White High
2 - 12
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Wand Emulation Idle
The idle describes the state of the scanner when no data is being transmitted.
When in Wand Emulation mode, you must set the scanner’s idle state to match
the idle state for the device to which the scanner is connected. Default = Idle
High.
* Idle High
Idle Low
Wand Emulation
Note: Changing primary wand emulation settings also changes the secondary
wand emulation settings (see Secondary Code 39 Wand Emulation on
page 6-2).
Data Block Size
Note: This option is not applicable to Laser Emulation Raw Output (see
Secondary Laser Emulation on page 6-3).
This transmits the data in smaller blocks to prevent buffer overflow. Default = 40.
20
* 40
60
80
IT5600/IT5800 User’s Guide
2 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Delay Between Blocks
Note: This option is not applicable to Laser Emulation Raw Output (see
Secondary Laser Emulation on page 6-3).
This sets the delay time between data blocks. Default = 50ms.
5ms
* 50ms
150ms
500ms
Overall Checksum
Note: This option is not applicable to Laser Emulation Raw Output (see
Secondary Laser Emulation on page 6-3).
When this option is turned on, a computed check character is added at the end
of the entire message. The check character is the character which when
Exclusive-OR’d with every preceding character of the message yields a result of
0x00 (00H). Default = Off.
On
* Off
2 - 14
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
3
Output
Good Read Indicators
Beeper – Good Read
The beeper may be programmed On or Off in response to a good read. Turning
this option off, only turns off the beeper response to a good read indication. All
error and menu beeps are still audible. Default = On.
* On
Off
Beeper Volume – Good Read
The beeper volume codes modify the volume of the beep the scanner emits on
a good read. Default = Medium for the IT5600, High for the IT5800.
Low
Medium
High
Off
Beeper Pitch – Good Read
The beeper pitch codes modify the pitch (frequency) of the beep the scanner
emits on a good read. Default = Medium.
Low (1600 Hz)
* Medium (3250 Hz)
High (4200 Hz)
IT5600/IT5800 User’s Guide
3 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Beeper Duration – Good Read
The beeper duration codes modify the length of the beep the scanner emits on a
good read. Default = Normal.
* Normal Beep
Short Beep
LED – Good Read
The LED indicator can be programmed On or Off in response to a good read.
Default = On.
* On
Off
Number of Beeps – Good Read
The number of beeps of a good read can be programmed from 1 - 9. The same
number of beeps will be applied to the beeper and LED in response to a good
read. For example, if you program this option to have five beeps, there will be
five beeps and five LED flashes in response to a good read. The beeps and LED
flashes are in sync with one another. To change the number of beeps, scan the
bar code below and then scan a digit (1-9) bar code and the Save bar code on
the Programming Chart inside the back cover of this manual. Default = One.
Number of Pulses
3 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Good Read Delay
This sets the minimum amount of time before the scanner can read another bar
code. Default = No Delay.
* No Delay
Short Delay (500 ms)
Medium Delay (1000 ms)
Long Delay (1500 ms)
User-Specified Good Read Delay
If you want to set your own length for the good read delay, scan the bar code
below, then set the delay (from 0-30,000 milliseconds) by scanning digits from
the inside back cover, then scanning Save.
Trigger Modes
Manual/Serial Trigger
You can activate the scanner either by pressing the trigger, or using a serial
trigger command (see Trigger Commands on page 11-4). When in manual
trigger mode, the scanner scans until a bar code is read, or until the trigger is
released.
When in serial mode, the scanner scans until a bar code has been read or until
the deactivate command is sent. In serial mode, the scanner can also be set to
turn itself off after a specified time has elapsed (see Read Time-Out, which
follows).
* Manual/Serial Trigger
IT5600/IT5800 User’s Guide
3 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Read Time-Out
Use this selection to set a time-out (in milliseconds) of the scanner’s trigger when
using serial commands to trigger the scanner. Once the scanner has timed out,
you can activate the scanner either by pressing the trigger or using a serial
trigger command. After scanning the Read Time-Out bar code, set the time-out
duration (from 0-300,000 milliseconds) by scanning digits from the inside back
cover, then scanning Save. Default = 300,000.
Read Time-Out
Manual Trigger, Low Power
The scanner powers down until the trigger is pulled. When the trigger is pulled,
the scanner powers up and operates until there is no triggering for the time set
with the Low Power Time-Out bar code below. There is a delay of up to one
second in operation when the scanner is first triggered, but there is no delay
when operating in low power time-out mode.
Manual Trigger, Low Power
Note: Manual Trigger, Low Power cannot be used with keyboard wedge
applications.
Low Power Time-Out Timer
Scan the Low Power Time-Out bar code to change the time-out duration (in
seconds). Then scan the time-out duration (from 0-300 seconds) from the inside
back cover, and Save. Default = 120 seconds.
If there are no trigger pulls during the “low power time-out timer” interval, the
scanner goes in low power mode. Whenever the trigger is enabled, the “low
power time-out timer” is reset.
Low Power Time-Out
Automatic Trigger
The scanner scans continuously at full power with illumination fully on.
disabled.
Automatic Trigger
3 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Presentation Mode
Note: Presentation mode does not work when a scanner is programmed for the
laser emulation interface.
Note: If the Presentation Mode selection is enabled, the aimer beam option is
disabled.
The LEDs are off until a bar code is presented to the scanner. Then the LEDs
turn on automatically to read the code. Presentation Mode uses ambient light to
detect the bar codes. If the light level in the room is not high enough,
Presentation Mode will not work properly.
Presentation Mode
Hands Free Time-Out
The Automatic Trigger and Presentation Modes are referred to as “hands free”
modes. If the imager’s trigger is pulled when using a hands free mode, the
imager changes to manual trigger mode. You can set the time the imager should
remain in manual trigger mode by setting the Hands Free Time-Out. Once the
time-out value is reached, (if there have been no further trigger pulls) the imager
reverts to the original hands free mode.
Scan the Hands Free Time-Out bar code, then scan the time-out duration (from
0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000
ms.
Hands Free Time-Out
Reread Delay
This sets the time period before the scanner can read the same bar code a
second time. Setting a reread delay protects against accidental rereads of the
same bar code. Longer delays are effective in minimizing accidental rereads at
POS (point of sale). Use shorter delays in applications where repetitive bar code
scanning is required. Default = Medium.
IT5600/IT5800 User’s Guide
3 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Reread Delay only works when in automatic trigger mode (see page 3-4).
Short (500 ms)
* Medium (750 ms)
Long (1000 ms)
Extra Long (2000 ms)
User-Specified Reread Delay
If you want to set your own length for the reread delay, scan the bar code below,
then set the delay (from 0-30,000 milliseconds) by scanning digits from the inside
back cover, then scanning Save.
User-Specified Reread Delay
3 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Aimer Beam Delay (Aimer Beam option only)
The Aimer Beam Delay allows a delay time for the operator to aim the reader
before the standard illumination and decoding starts. The quickset codes sets
the time between when the trigger is pulled and when the decode starts to either
1 or 2 seconds. During the delay time, the aiming beam appears, but the
illumination LEDs won’t turn on until the delay time is over.
* Off (no delay)
1 second
2 seconds
User-Specified Aimer Beam Delay
If you want to set your own length for the duration of the delay, scan the bar code
below, then set the time-out by scanning digits (0 - 4000 ms) from the
Programming Chart inside the back cover of this manual and then scan Save.
Delay Duration
Aimer Mode (Aimer Beam option only)
If you are reading codes in applications that exhibit high ambient light, you can
turn on the aimer beam to assist you in reliably finding and scanning a code.
Select Off if you don’t want to use the aimer beam.
Off
* On
IT5600/IT5800 User’s Guide
3 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Aimer Beam Time-Out (Aimer Beam option only)
Aimer Beam Time-Out powers down the aimer beam after a time-out if the trigger
is still pulled and there isn’t a valid decode. Scan the bar code below, then set
the time-out by scanning digits (from 0 - 240,000 ms) from the Programming
Chart inside the back cover of this manual and then scan Save. Default = 0 (no
time-out)
Time-Out Duration
Centering Window
Use the centering feature to narrow the scanner’s field of view so the scanner
reads only the bar code you want. When centering is turned on, the scanner only
reads codes that intersect or are contained within the centering window you set
up. At least part of a bar code must be within the window to be decoded or output
by the scanner.
To change the left or right edge of the centering window, scan Centering On, then
scan one of the following bar codes. Then scan the percent you want to shift the
centering window using digits on the inside back cover of this manual. Scan
Save. Default Centering = 40% for Left, 60% for Right.
Centering On
* Centering Off
Left of Centering Window
Right of Centering Window
3 - 8
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The figure below illustrates the percentage range from 1 to 100%.
40%
60%
30%
70%
80%
20%
90%
10%
0%
100%
Example: If you have two bar codes next to one another and the centering
window is set to 40% left edge and 60% right edge, only the bar
code that intersects that window will be decoded.
Decoded bar code
40%
60%
30%
70%
80%
20%
90%
10%
0%
100%
IT5600/IT5800 User’s Guide
3 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Output Sequence Overview
Require Output Sequence
When turned off, the bar code data will be output to the host as the scanner
decodes it. When turned on, all output data must conform to an edited sequence
or the scanner will not transmit the output data to the host device.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Output Sequence Editor
This programming selection allows you to program the scanner to output data
(when scanning more than one symbol) in whatever order your application
requires, regardless of the order in which the bar codes are scanned. Reading
shown below. These are the defaults. Be certain you want to delete or clear all
Note: To make Output Sequence Editor selections, you’ll need to know the code
I.D., code length, and character match(es) your application requires. Use
the Alphanumeric symbols (inside back cover) to read these options.
To Add an Output Sequence
1. Scan the Enter Sequence symbol (see Multiple Symbols, page 3-13).
2. Code I.D.
On the Symbology Chart on page A-1, find the symbology to which you want
to apply the output sequence format. Locate the Hex value for that symbol-
ogy and scan the 2 digit hex value from the Programming Chart (inside back
cover).
3. Length
Specify what length (up to 9999 characters) of data output will be acceptable
for this symbology. Scan the four digit data length from the Programming
Chart. (Note: 50 characters is entered as 0050. 9999 is a universal num-
ber, indicating all lengths.) When calculating the length, you must count any
programmed prefixes, suffixes, or formatted characters as part of the length
(unless using 9999).
4. Character Match Sequences
On the ASCII Conversion Chart (Code Page 1252), page A-2, find the Hex
value that represents the character(s) you want to match. Use the Program-
ming Chart to read the alphanumeric combination that represents the ASCII
characters. (99 is the Universal number, indicating all characters.)
5. End Output Sequence Editor
Scan F F to enter an Output Sequence for an additional symbology, or Save
to save your entries.
Other Programming Selections
•Discard
This exits without saving any Output Sequence changes.
3 - 10
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Output Sequence Editor
Enter Sequence
Default Sequence
Require Output Sequence
When an output sequence is Required, all output data must conform to an edited
sequence or the scanner will not transmit the output data to the host device.
When it’s On/Not Required, the scanner will attempt to get the output data to
conform to an edited sequence, but if it cannot, the scanner transmits all output
data to the host device as is.
When the output sequence is Off, the bar code data is output to the host as the
scanner decodes it.
Note: This selection is unavailable when the Multiple Symbols Selection is
turned on.
Required
On/Not Required
* Off
Output Sequence Example
In this example, you are scanning Code 93, Code 128, and Code 39 bar codes,
but you want the scanner to output Code 39 1st, Code 128 2nd, and Code 93
3rd, as shown below.
IT5600/IT5800 User’s Guide
3 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: Code 93 must be enabled to use this example.
A - Code 39
B - Code 128
C - Code 93
You would set up the sequence editor with the following command line:
SEQBLK62999941FF6A999942FF69999943FF
The breakdown of the command line is shown below:
SEQBLKsequence editor start command
62 code identifier for Code 39
9999 code length that must match for Code 39, 9999 = all lengths
41 start character match for Code 39, 41h = “A”
FF termination string for first code
6A code identifier for Code 128
9999 code length that must match for Code 128, 9999 = all lengths
42 start character match for Code 128, 42h = “B”
FF termination string for second code
69 code identifier for Code 93
9999 code length that must match for Code 93, 9999 = all lengths
43 start character match for Code 93, 43h = “C”
FF termination string for third code
To program the previous example using specific lengths, you would have to
count any programmed prefixes, suffixes, or formatted characters as part of the
length. If you use the example on page 3-11, but assume a <CR> suffix and
specific code lengths, you would use the following command line:
SEQBLK62001141FF6A001242FF69001143FF
3 - 12
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
The breakdown of the command line is shown below:
SEQBLK sequence editor start command
62
code identifier for Code 39
0011
41
FF
Code 39 code length (9) plus CR suffix (2) = 11
start character match for Code 39, 41h = “A”
termination string for first code
6A
code identifier for Code 128
0012
42
FF
Code 128 code length (10) plus CR suffix (2) = 12
start character match for Code 128, 42h = “B”
termination string for second code
69
code identifier for Code 93
0011
43
FF
Code 93 code length (9) plus CR suffix (2) = 11
start character match for Code 93, 43h = “C”
termination string for third code
Multiple Symbols
Note: This feature does not work when the scanner is in Low Power mode.
When this programming selection is turned On, it allows you to read multiple
symbols with a single pull of the scanner’s trigger. If you press and hold the
trigger, aiming the scanner at a series of symbols, it reads unique symbols once,
beeping (if turned on) for each read. The scanner attempts to find and decode
new symbols as long as the trigger is pulled. When this programming selection
is turned Off, the scanner will only read the symbol closest to the aiming beam.
On
* Off
No Read
With No Read turned On, the scanner sends an “NR” to the host if you pull and
release the trigger without reading a code (e.g., bad bar code). If No Read is
turned Off, the “NR” will not be sent to the host.
On
* Off
IT5600/IT5800 User’s Guide
3 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
If you want a different notation than “NR,” for example, “Error,” or “Bad Code,”
you can edit the output message using the Data Formatter (page 5-5). The hex
code for the No Read symbol is 9C.
Video Reverse
Video Reverse is used to allow the scanner to read bar codes that are inverted.
The “Off” bar code below is an example of this type of bar code.
Note: If additional menuing is required, Video Reverse must be disabled to read
the menu bar codes and then re-enabled after menuing is completed.
On
* Off
3 - 14
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
4
Data Editing
Prefix/Suffix Overview
When a bar code is scanned, additional information is sent to the host computer
along with the bar code data. This group of bar code data and additional,
user-defined data is called a “message string.” The selections in this section are
used to build the user-defined data into the message string.
Prefix and Suffix characters are data characters that can be sent before and after
scanned data. You can specify if they should be sent with all symbologies, or
only with specific symbologies. The following illustration shows the breakdown
of a message string:
Prefix
1-11
alpha numeric
characters
Scanned Data
Suffix
1-11
alpha numeric
characters
variable length
Points to Keep In Mind
•
It is not necessary to build a message string. The selections in this chapter
are only used if you wish to alter the default settings. Default prefix = None.
Default suffix = None.
•
•
A prefix or suffix may be added or cleared from one symbology or all
symbologies.
You can add any prefix or suffix from the ASCII Conversion Chart (Code Page
1252) on page A-2, plus Code I.D. and AIM I.D.
•
•
You can string together several entries for several symbologies at one time.
Enter prefixes and suffixes in the order in which you want them to appear on
the output.
IT5600/IT5800 User’s Guide
4 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
To Add a Prefix or Suffix:
the Appendix A) for the symbology to which you want to apply the prefix
or suffix. For example, for Code 128, Code ID is “j” and Hex ID is “6A”.
Step 3. Scan the 2 hex digits from the Programming Chart inside the back
cover of this manual or scan 9, 9 for all symbologies.
Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page
1252) on page A-2, for the prefix or suffix you wish to enter.
Step 5. Scan the 2 digit hex value from the Programming Chart inside the back
cover of this manual.
Step 6. Repeat Steps 4 and 5 for every prefix or suffix character.
Step 7. To add the Code I.D., scan 5, C, 8, 0.
To add AIM I.D., scan 5, C, 8, 1.
To add a backslash (\), scan 5, C, 5, C.
Note: To add a backslash (\) as in Step 7, you must scan 5C twice – once to
create the leading backslash and then to create the backslash itself.
Repeat Steps 1-6 to add a prefix or suffix for another symbology.
Example: Add a Suffix to a specific symbology
To send a CR (carriage return)Suffix for UPC only:
Step 1. Scan Add Suffix.
Step 2. Determine the 2 digit hex value from the Symbology Chart (included in
the Appendix A) for UPC.
Step 3. Scan 6, 3 from the Programming Chart inside the back cover of this
manual.
Step 4. Determine the hex value from the ASCII Conversion Chart (Code Page
1252) on page A-2, for the CR (carriage return).
Step 5. Scan 0, D from the Programming Chart inside the back cover of this
manual.
Step 6. Scan Save, or scan Discard to exit without saving.
4 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
You can clear a single prefix or suffix, or clear all prefixes/suffixes for a
select is deleted from the symbology you want. When you Clear All Prefixes
(Suffixes), all the prefixes or suffixes for a symbology are deleted.
Step 1. Scan the Clear One Prefix or Clear One Suffix symbol.
Step 2. Determine the 2 digit Hex value from the Symbology Chart (included in
the Appendix A) for the symbology from which you want to clear the pre-
fix or suffix.
Step 3. Scan the 2 digit hex value from the Programming Chart inside the back
cover of this manual or scan 9, 9 for all symbologies.
Your change is automatically saved.
To Add a Carriage Return Suffix to all Symbologies
Scan the following bar code if you wish to add a carriage return suffix to all
symbologies at once. This action first clears all current suffixes, then programs
a carriage return suffix for all symbologies.
Add CR Suffix
All Symbologies
Prefix Selections
Add Prefix
Clear One Prefix
Clear All Prefixes
IT5600/IT5800 User’s Guide
4 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Suffix Selections
Add Suffix
Clear All Suffixes
Function Code Transmit
When this selection is enabled and function codes are contained within the
scanned data, the scanner transmits the function code to the terminal. Charts of
these function codes are provided in Supported Interface Keys starting on
page 8-3. When the scanner is in keyboard wedge mode, the scan code is
converted to a key code before it is transmitted. Default = Enable.
* Enable
Disable
Intercharacter, Interfunction, and Intermessage Delays
Some terminals drop information (characters) if data comes through too quickly.
Intercharacter, interfunction, and intermessage delays slow the transmission of
data, increasing data integrity.
Each delay is composed of a 5 millisecond step. You can program up to 99 steps
(of 5 ms each) for a range of 0-495 ms.
4 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed between the
transmission of each character of scanned data. Scan the Intercharacter Delay
bar code below, then scan the number of milliseconds and the SAVE bar code
using the Programming Chart inside the back cover of this manual.
Prefix
Scanned Data
Suffix
1
2
3
4
5
Intercharacter Delay
Intercharacter Delay
To remove this delay, scan the Intercharacter Delay bar code, then set the
inside the back cover of this manual.
Note: Intercharacter delays are not supported in USB serial emulation.
User Specified Intercharacter Delay
An intercharacter delay of up to 495 milliseconds may be placed after the
transmission of a particular character of scanned data. Scan the Delay Length
bar code below, then scan the number of milliseconds and the SAVE bar code
using the Programming Chart inside the back cover of this manual.
Next, scan the Character to Trigger Delay bar code, then the 2-digit hex value
for the ASCII character that will trigger the delay ASCII Conversion Chart (Code
Page 1252) on page A-2.
Delay Length
Character to Trigger Delay
To remove this delay, scan the Delay Length bar code, and set the number of
steps to 0. Scan the SAVE bar code using the Programming Chart inside the
back cover of this manual.
IT5600/IT5800 User’s Guide
4 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Interfunction Delay
An interfunction delay of up to 495 milliseconds may be placed between the
transmission of each segment of the message string. Scan the Interfunction
Delay bar code below, then scan the number of milliseconds and the SAVE bar
code using the Programming Chart inside the back cover of this manual.
Prefix
STX
Scanned Data
3 4
Suffix
CR
1
HT
2
5
LF
Interfunction Delays
Interfunction Delay
number of steps to 0. Scan the SAVE bar code using the Programming Chart
inside the back cover of this manual.
Intermessage Delay
An intermessage delay of up to 495 milliseconds may be placed between each
scan transmission. Scan the Intermessage Delay bar code below, then scan
the number of milliseconds and the SAVE bar code using the Programming
Chart inside the back cover of this manual.
1st Scan Transmission 2nd Scan Transmission
Intermessage Delay
Intermessage Delay
To remove this delay, scan the Intermessage Delay bar code, then set the
number of steps to 0. Scan the SAVE bar code using the Programming Chart
inside the back cover of this manual.
4 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
5
Data Formatting
You may use the Data Format Editor to change the scanner’s output. For
example, you can use the Data Format Editor to insert characters at certain
points in bar code data as it is scanned. The selections in the following pages
are used only if you wish to alter the output. Default Data Format setting = None.
Normally, when you scan a bar code, it gets outputted automatically; however
when you do a format, you must use a “send” command (see Send Commands
on page 5-2) within the format program to output data.
Multiple formats may be programmed into the scanner. They are stacked in the
order in which they are entered. However, the following list presents the order
in which formats are applied:
1. Specific Term ID, Actual Code ID, Actual Length
2. Specific Term ID, Actual Code ID, Universal Length
3. Specific Term ID, Universal Code ID, Actual Length
4. Specific Term ID, Universal Code ID, Universal Length
5. Universal Term ID, Actual Code ID, Actual Length
6. Universal Term ID, Actual Code ID, Universal Length
7. Universal Term ID, Universal Code ID, Actual Length
8. Universal Term ID, Universal Code ID, Universal Length
If you have changed data format settings, and wish to clear all formats and return
to the factory defaults, scan the Default Data Format code on page 5-4.
To Add a Data Format
Step 1. Scan the Enter Data Format symbol (page 5-4).
Step 2. Primary/Alternate Format
Determine if this will be your primary data format, or one of 3 alternate
one bar code using a different data format. After the one bar code has
been read, the scanner reverts to the primary data format. See page 5-
5.) If you are programming the primary format, scan 0 using the Pro-
gramming Chart inside the back cover of this manual. If you are pro-
gramming an alternate format, scan 1, 2, or 3, depending on the
alternate format you are programming.
Step 3. Terminal Type
Refer to the Supported Terminals Chart (page 2-2) and locate the Ter-
minal ID number for your PC. Scan three numeric bar codes on the
IT5600/IT5800 User’s Guide
5 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
inside back cover to program the scanner for your terminal ID (you must
enter 3 digits). For example, scan 0 0 3 for an AT wedge.
Note: The wildcard for all terminal types is 099.
Step 4. Code I.D.
In the Appendix A, find the symbology to which you want to apply the
data format. Locate the Hex value for that symbology and scan the 2
digit hex value from the Programming Chart inside the back cover of
this manual.
Step 5. Length
Specify what length (up to 9999 characters) of data will be acceptable
ming Chart inside the back cover of this manual. (Note: 50 characters is
entered as 0050. 9999 is a universal number, indicating all lengths.)
Step 6. Editor Commands
Refer to the Format Editor Commands Chart (page 5-2). Scan the sym-
bols that represent the command you want to enter. 94 alphanumeric
characters may be entered for each symbology data format.
Step 7. Scan Save from the Programming Chart inside the back cover of this
manual to save your entries.
Other Programming Selections
•
Clear One Data Format
This deletes one data format for one symbology. If you are clearing the
primary format, scan 0 from the Programming Chart inside the back cover of
this manual. If you are clearing an alternate format, scan 1, 2, or 3, depending
on the alternate format you are clearing. Scan the Terminal Type (refer to the
Supported Terminals Chart on page 2-2), Code I.D. (refer to the Symbology
Chart on page A-1), and the bar code data length for the specific data format
that you want to delete. All other formats remain unaffected.
•
•
Save from the Programming Chart inside the back cover of this manual
This exits, saving any Data Format changes.
This exits without saving any Data Format changes.
Data Format Editor Commands
Send Commands
F1 Send all characters followed by “xx” key or function code, starting from cur-
rent cursor position. Syntax = F1xx (xx stands for the hex value for an
ASCII code, see ASCII Conversion Chart (Code Page 1252) on page A-2.)
F2 Send “nn” characters followed by “xx” key or function code, starting from
current cursor position. Syntax = F2nnxx (nn stands for the numeric value
5 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
ASCII code. See ASCII Conversion Chart (Code Page 1252) on page A-2.)
F3 Send up to but not including “ss” character (Search and Send) starting from
current cursor position, leaving cursor pointing to “ss” character followed by
“xx” key or function code. Syntax = F3ssxx (ss and xx both stand for the
hex values for ASCII codes, see ASCII Conversion Chart (Code Page
1252) on page A-2.)
F4 Send “xx” character “nn” times (Insert) leaving cursor in current cursor posi-
tion. Syntax = F4xxnn (xx stands for the hex value for an ASCII code, see
ASCII Conversion Chart (Code Page 1252) on page A-2, and nn is the
numeric value (00-99) for the number of times it should be sent.)
E9 Send all but the last “nn” characters, starting from the current cursor posi-
tion. Syntax = E9nn (nn is the numeric value (00-99) for the number of
characters that will not be sent at the end of the message.)
Move Commands
F5 Move the cursor ahead “nn” characters from current cursor position.
Syntax = F5nn (nn stands for the numeric value (00-99) for the number of
characters the cursor should be moved ahead.)
characters the cursor should be moved back.)
F7 Move the cursor to the beginning of the data string. Syntax = F7.
Search Commands
F8 Search ahead for “xx” character from current cursor position, leaving cursor
2.)
2.)
E6 Search ahead for the first non “xx” character from the current cursor posi-
tion, leaving cursor pointing to non “xx” character. Syntax = E6xx (xx
stands for the hex value for an ASCII code, see ASCII Conversion Chart
(Code Page 1252) on page A-2.
E7 Search back for the first non “xx” character from the current cursor position,
leaving cursor pointing to non “xx” character. Syntax = E7xx (xx stands for
the hex value for an ASCII code, see ASCII Conversion Chart (Code Page
1252) on page A-2.)
FB Suppress all occurrences of up to 15 different characters, starting at the cur-
rent cursor position, as the cursor is advanced by other commands. When
the FC command is encountered, the suppress function is terminated. The
cursor is not moved by the FB command. Syntax = FBnnxxyy . .zz where
nn is a count of the number of suppressed characters in the list and xxyy ..
IT5600/IT5800 User’s Guide
5 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
zz is the list of characters to be suppressed. (xx stands for the hex value for
an ASCII code, see ASCII Conversion Chart (Code Page 1252) on page A-
2.)
FC Disables suppress filter and clear all suppressed characters. Syntax = FC.
E4 Replaces up to 15 characters in the data string with user specified charac-
tax = E4nnxx xx yy yy ...zz zz where nn is the total count of both
1
2
1
2
1
2
characters to be replaced plus replacement characters; xx defines charac-
1
ters to be replaced and xx defines replacement characters, continuing
2
through zz and zz .
1
2
E5 Terminates character replacement. Syntax = E5.
FE Compare character in current cursor position to the character “xx.” If char-
acters are equal, increment cursor. If characters are not equal, no format
match. Syntax = FExx (xx stands for the hex value for an ASCII code, see
ASCII Conversion Chart (Code Page 1252) on page A-2.)
EC Check to make sure there is an ASCII number at the current cursor position.
If character is not numeric, format is aborted. Syntax = EC.
ED Check to make sure there is a non-numeric ASCII character at the current
cursor position. If character is numeric, format is aborted. Syntax = ED.
Data Format Editor
Enter Data Format
* Default Data Format
Clear One Data Format
Clear All Data Formats
Save
Discard
5 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Data Formatter
When Data Formatter is turned off, the bar code data is output to the host as read
(including prefixes and suffixes). Choose one of the following options. Default =
Data Formatter On.
* Data Formatter On,
but Not Required
Data Formatter Off
When Data Formatter is required, all input data must conform to an edited format
or the scanner does not transmit the input data to the host device.
Data Format On, Format Required
Alternate Data Formats
Alternate formats allow you “single shot” capability to scan one bar code using a
different data format than your primary format. When data formats are
programmed (see page 5-1), you must input whether you are programming the
primary format, or an alternate format numbered 1, 2, or 3.
An alternate format is initiated by scanning one of the 3 alternate format bar
codes below. The scanner will scan the next bar code, formatting the data with
the selected alternate format, then revert immediately to the primary format.
Alternate Data Format 1
Alternate Data Format 2
Alternate Data Format 3
IT5600/IT5800 User’s Guide
5 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
5 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
6
Secondary Interface
By switching secondary interface cables, the IT5600/5800 scanner, for example,
can communicate with a portable data terminal (secondary interface) in addition
to the host terminal (primary interface). See the tables below for the secondary
interfaces for each IT5600/5800 model.
IT5600 Models
Secondary
Interfaces
Models
Primary Interfaces
5600SRX00
5600SRX30
TTL Level 232
Laser Emulation
True RS-232
True RS-232, True RS-232
serial wedge
5600SRX50
Keyboard wedge, TTL level
232, TTL level 232 serial
Wand Emulation, TTL
level 232
wedge, IBM 4683, wand emula-
tion, USB keyboard, USB HID,
USB retail (IBM SurePOS)
IT5800 Models
The chart below lists the IT5800 scanner models. “SR” indicates “Standard
Range” linear optics. If the product number has the number one (1) as the last
character, the unit contains the aimer beam option (e.g., 5800SR001).
Secondary
Interfaces
Models
Primary Interfaces
5800SR000
5800SR030
TTL Level 232
Laser Emulation
True RS-232
True RS-232, True RS-232
serial wedge
5800SR05X
Keyboard wedge, TTL level
232, TTL level 232 serial
Wand Emulation, TTL
level 232
wedge, IBM 4683, wand emula-
tion, USB keyboard, USB HID,
Enabling the Secondary Interface
The secondary interface can be programmed at any time.
IT5600/IT5800 User’s Guide
6 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
You can temporarily disable the secondary interface, but still retain the
secondary interface settings in the imager’s memory by scanning the Disable
bar code below. To re-enable the secondary interface, scan the Enable bar
code. Default =Disable.
* Disable
Enable
Secondary RS-232 Connection
All communication parameters between the scanner and terminal must match for
correct data transfer through the serial port using RS-232 protocol.
RS-232 programmable selections are used by both the primary and secondary
interfaces. Changing an RS-232 parameter (e.g., baud rate or parity), while in
primary or secondary mode will affect both interfaces. If you want to change the
RS-232 settings, refer to the Connecting the Scanner with RS-232 Serial Port
section on pages 2-8 to 2-11.
RS-232 Interface
Secondary Code 39 Wand Emulation
In Wand Emulation mode, the scanner decodes the bar code then sends data in
the same format as a wand scanner. The Code 39 Format converts all
symbologies to Code 39. The Same Code Format transmits UPC, EAN, Code
128 and Interleaved 2 of 5 without any changes, but converts all other
symbologies to Code 39. These codes set the transmission rate to 25 inches per
second and the output polarity to black, high.
The Code 39 Format bar code below sets the terminal ID to 61, and the Same
Code Format bar code sets the terminal ID to 64.
Wand Emulation
Code 39 Format
Wand Emulation
Same Code Format
6 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Secondary Laser Emulation
Use this selection when connecting to a secondary terminal with integral
decoding. This also sets the transmission rate to 36 scans per second, the
polarity to white high, and deletes all prefixes and suffixes.
* Laser Emulation
Same Code Output
When you scan the following bar code, the imager sends the raw data edges to
the host for host decoding. This also sets the transmission rate to 36 scans per
second and the polarity to white high.
Laser Emulation
Raw Output
When you scan the following bar code, the scanner decodes and re-encodes the
data and sends the data to the host as Code 39.
Laser Emulation
Code 39 Output
Laser Emulation Transmission Rate
The transmission rate is limited by the terminal’s ability to receive data without
dropping characters. Default = 36 scans/second.
* 36
100
IT5600/IT5800 User’s Guide
6 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Laser Emulation Polarity
The Polarity can be sent as standard with white bars high, or reversed with black
bars high. Default = White High.
* White High
Black High
Laser Emulation Idle
The idle describes the state of the scanner when no data is being transmitted.
When in Non Decoded mode, you must set the scanner’s idle state to match the
idle state for the device to which the scanner is connected. Default = Idle High.
Idle Low
* Idle High
Secondary Trigger Mode
Manual Trigger: You must press the scanner trigger to scan. When not
scanning, idle power is maintained. Default = Manual Trigger.
* Manual Trigger
Automatic Trigger: The scanner scans continuously at full power.
Automatic Trigger
Presentation Mode: The LEDs are off until a bar code is presented to the
Mode uses ambient light to detect the bar codes.
Presentation Mode
6 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Manual Trigger, Low Power: Scan the Manual Trigger, Low Power bar code
below and the scanner “sleeps” until the trigger is pulled. When the trigger is
pulled, the scanner wakes up and operates at normal power until there is no
triggering for the time set with the Low Power Time-Out bar code. Then, the
scanner goes to “sleep” again.
Manual Trigger, Low Power
Low Power Time-Out: Scan the Low Power Time-Out bar code to change the
time-out duration. Then scan the time-out duration (from 0-300 seconds) from
the inside back cover and Save. Default = 120 seconds.
Low Power Time-Out
Hands Free Time-Out
The Automatic Trigger and Presentation Modes are referred to as “hands free”
modes. If the imager’s trigger is pulled when using a hands free mode, the
imager changes to manual trigger mode. You can set the time the imager should
remain in manual trigger mode by setting the Hands Free Time-Out. Once the
time-out value is reached, (if there have been no further trigger pulls) the imager
reverts to the original hands free mode.
Note: If you change the time-out duration for the secondary interface, the
duration of the primary interface will also be changed.
Scan the Hands Free Time-Out bar code, then scan the time-out duration (from
0-300,000 milliseconds) from the inside back cover, and Save. Default = 5,000
ms.
Hands Free Time-Out
IT5600/IT5800 User’s Guide
6 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
6 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
7
Symbologies
Introduction
This programming section contains the following menu selections. Refer to
Chapter 11 for settings and defaults.
•
•
•
•
•
•
•
•
•
•
•
•
•
All Symbologies
China Post
•
•
•
•
•
•
•
•
•
•
•
•
•
IATA Code 2 of 5
Interleaved 2 of 5
Korea Post
Matrix 2 of 5
Coupon Code
MSI
Codabar
Codablock F
Code 2 of 5
Code 11
Code 16K
Plessey Code
PosiCode
RSS-14
Code 39
Code 32 Pharmaceutical (PARAF)
Code 49
Telepen
Code 93
Trioptic
Code 128
UPC-A
EAN/JAN
UPC-E
All Symbologies
If you want to decode all the symbologies allowable for your scanner, scan the
All Symbologies On code. If on the other hand, you want to decode only a
particular symbology, scan All Symbologies Off followed by the On symbol for
that particular symbology.
All Symbologies On
All Symbologies Off
IT5600/IT5800 User’s Guide
7 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Message Length
You are able to set the valid reading length of some of the bar code symbologies.
If the data length of the scanned bar code doesn’t match the valid reading length,
the scanner will issue an error beep. You may wish to set the same value for
minimum and maximum length to force the scanner to read fixed length bar code
data. This helps reduce the chances of a misread.
EXAMPLE:Decode only those bar codes with a count of 9-20 characters.
Min. length = 09
Max. length = 20
EXAMPLE:Decode only those bar codes with a count of 15 characters.
Min. length = 15 Max. length = 15
For a value other than the minimum and maximum message length defaults,
scan the bar codes included in the explanation of the symbology, then scan the
digit value of the message length and Save bar codes on the Programming Chart
inside the back cover of this manual. The minimum and maximum lengths and
the defaults are included with the respective symbologies.
7 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Codabar
Codabar
<Default All Codabar Settings>
* On
Off
Codabar Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You
may either transmit, or not transmit Start/Stop characters.
Default = Don’t Transmit.
Transmit
* Don’t Transmit
Codabar Check Character
Codabar check characters are created using different “modulos.” You can
program the scanner to read only Codabar bar codes with Modulo 16 check
characters. Default = No Check Character.
No Check Character indicates that the scanner reads and transmits bar code
data with or without a check character.
When Check Character is set to Validate and Transmit, the scanner will only
read Codabar bar codes printed with a check character, and will transmit this
character at the end of the scanned data.
IT5600/IT5800 User’s Guide
7 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Character is set to Validate, but Don’t Transmit, the unit will only
read Codabar bar codes printed with a check character, but will not transmit the
check character with the scanned data.
* No Check Character
Validate Modulo 16, but
Don’t Transmit
Validate Modulo 16 and Transmit
Codabar Concatenation
Codabar supports symbol concatenation. When you enable concatenation, the
scanner looks for a Codabar symbol having a “D” start character, adjacent to a
symbol having a “D” stop character. In this case the two messages are
concatenated into one with the “D” characters omitted. Default = On.
Character
Start
Stop
Start
Stop
Codabar
A12D
D34A
Select Require to prevent the scanner from decoding a single “D” Codabar
symbol without its companion. This selection has no effect on Codabar symbols
without Stop/Start D characters.
* On
Off
Require
7 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Codabar Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 2-60. Minimum Default = 4, Maximum Default = 60.
Minimum Message Length
Maximum Message Length
Code 39
< Default All Code 39 Settings >
Code 39
* On
Off
Code 39 Start/Stop Characters
Start/Stop characters identify the leading and trailing ends of the bar code. You
may either transmit, or not transmit Start/Stop characters. Default = Don’t
Transmit.
Transmit
* Don’t Transmit
IT5600/IT5800 User’s Guide
7 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 39, continued
Code 39 Check Character
No Check Character indicates that the scanner reads and transmits bar code
data with or without a check character.
When Check Character is set to Validate, but Don’t Transmit, the unit only
reads Code 39 bar codes printed with a check character, but will not transmit the
check character with the scanned data.
When Check Character is set to Validate and Transmit, the scanner only reads
Code 39 bar codes printed with a check character, and will transmit this character
at the end of the scanned data. Default = No Check Character.
* No Check Character
Validate, but Don’t Transmit
Validate and Transmit
Code 39 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 0-48. Minimum Default = 0, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 39, continued
Code 39 Append
This function allows the scanner to append the data from several Code 39 bar
codes together before transmitting them to the host computer. When this
function is enabled, the scanner stores those Code 39 bar codes that start with
a space (excluding the start and stop symbols), and does not immediately
transmit the data. The scanner stores the data in the order in which the bar
codes are read, deleting the first space from each. The scanner transmits the
appended data when it reads a Code 39 bar code that starts with a character
other than a space. Default = Off.
On
* Off
Code 32 Pharmaceutical (PARAF)
Code 32 Pharmaceutical is a form of the Code 39 symbology used by Italian
pharmacies. This symbology is also known as PARAF.
IT5600/IT5800 User’s Guide
7 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Note: Trioptic Code must be turned off to scan Code 32 Pharmaceutical codes.
On
* Off
Full ASCII
If Full ASCII Code 39 decoding is enabled, certain character pairs within the bar
code symbol will be interpreted as a single character. For example: $V will be
decoded as the ASCII character SYN, and /C will be decoded as the ASCII
character #. Default = On.
NUL %U
SOH $A
STX $B
ETX $C
EOT $D
ENQ $E
ACK $F
BEL $G
BS $H
HT $I
DLE $P
DC1 $Q
DC2 $R
DC3 $S
DC4 $T
NAK $U
SYN $V
ETB $W
CAN $X
EM $Y
SUB $Z
ESC %A
FS %B
GS %C
RS %D
US %E
SP
!
SPACE
/A
/B
/C
/D
/E
/F
/G
/H
/I
0
1
2
3
4
5
6
7
8
9
:
0
@
A
B
C
D
E
F
%V
A
B
C
D
E
F
P
Q
R
S
T
U
V
W
X
Y
Z
[
P
‘
%W
+A
+B
+C
+D
+E
+F
+G
+H
+I
p
q
r
+P
+Q
+R
+S
+T
1
Q
a
b
c
d
e
f
“
2
R
#
$
%
&
‘
3
S
s
t
4
T
5
U
u
v
w
x
y
z
{
+U
+V
+W
+X
+Y
+Z
6
V
7
G
H
I
G
H
I
W
X
g
h
i
(
8
)
9
Y
LF $J
VT $K
FF $L
CR $M
SO $N
*
/J
/Z
%F
%G
%H
%I
%J
J
J
Z
j
+J
+
,
/K
/L
;
K
L
K
L
%K
%L
%M
%N
%O
k
l
+K
+L
%P
%Q
%R
%S
<
=
>
?
\
|
-
-
M
N
O
M
N
O
]
m
n
o
+M
+N
}
.
.
^
~
SI
$O
/
/O
_
+O DEL %T
Character pairs /M and /N decode as a minus sign and period respectively.
Character pairs /P through /Y decode as 0 through 9.
* Full ASCII On
Full ASCII Off
7 - 8
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 39 Code Page
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the bar
code being scanned was created using a code page that is different from the one
the host program is expecting. If this is the case, scan the bar code below, select
the code page with which the bar codes were created from the chart, Code Page
Mapping of Printed Bar Codes on page A-4, and scan the value and the SAVE
bar code from the Programming Chart inside the back cover of this manual. The
data characters should then appear properly.
Code 39 Code Page
Interleaved 2 of 5
< Default All Interleaved 2 of 5 Settings >
Interleaved 2 of 5
* On
Off
Check Digit
No Check Digit indicates that the scanner reads and transmits bar code data
with or without a check digit.
IT5600/IT5800 User’s Guide
7 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
When Check Digit is set to Validate, but Don’t Transmit, the unit only reads
Interleaved 2 of 5 bar codes printed with a check digit, but will not transmit the
check digit with the scanned data.
When Check Digit is set to Validate and Transmit, the scanner only reads
Interleaved 2 of 5 bar codes printed with a check digit, and will transmit this digit
at the end of the scanned data. Default = No Check Digit.
* No Check Digit
Validate, but Don’t Transmit
Validate and Transmit
Interleaved 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
7 - 10
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 93
Code 93
< Default All Code 93 Settings >
* On
Off
Code 93 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Minimum Message Length
Code 93 Code Page
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the bar
code being scanned was created using a code page that is different from the one
the host program is expecting. If this is the case, scan the bar code below, select
the code page with which the bar codes were created from the chart, Code Page
Mapping of Printed Bar Codes on page A-4, and scan the value and the SAVE
bar code from the Programming Chart inside the back cover of this manual. The
data characters should then appear properly.
Code 93 Code Page
IT5600/IT5800 User’s Guide
7 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 2 of 5
Code 2 of 5
<Default All Code 2 of 5 Settings>
On
* Off
Code 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
IATA Code 2 of 5
<Default All Code IATA 2 of 5 Settings>
7 - 12
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
IATA Code 2 of 5, continued
On
* Off
IATA Code 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 1-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
Matrix 2 of 5
<Default All Matrix 2 of 5 Settings>
Matrix 2 of 5
On
* Off
IT5600/IT5800 User’s Guide
7 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Matrix 2 of 5 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
Code 11
<Default All Code 11 Settings>
Code 11
On
* Off
Check Digits Required
This option sets whether 1 or 2 check digits are required with Code 11 bar codes.
Default = Two Check Digits.
One Check Digit
* Two Check Digits
7 - 14
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 11, continued
Code 11 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 1-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
Code 128
<Default All Code 128 Settings>
Code 128
* On
Off
IT5600/IT5800 User’s Guide
7 - 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 128, continued
ISBT 128 Concatenation
In 1994 the International Society of Blood Transfusion (ISBT) ratified a standard
for communicating critical blood information in a uniform manner. The use of
ISBT formats requires a paid license. The ISBT 128 Application Specification
describes 1) the critical data elements for labeling blood products, 2) the current
recommendation to use Code 128 due to its high degree of security and its
space-efficient design, 3) a variation of Code 128 that supports concatenation of
neighboring symbols, and 4) the standard layout for bar codes on a blood product
label. Use the bar codes below to turn concatenation on or off. Default =Off.
On
* Off
Code 128 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 0-80. Minimum Default = 0, Maximum Default = 80.
Minimum Message Length
Code 128 Code Page
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the bar
code being scanned was created using a code page that is different from the one
the host program is expecting. If this is the case, scan the bar code below, select
the code page with which the bar codes were created from the chart, Code Page
Mapping of Printed Bar Codes on page A-4, and scan the value and the SAVE
bar code from the Programming Chart inside the back cover of this manual. The
data characters should then appear properly.
Code 128 Code Page
7 - 16
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 128 Function Code Transmit
By default, Code 128 function codes are not transmitted with Code 128 bar code
data. However, if you wish to transmit Code 128 function codes with the bar code
data, scan the Function Codes On bar code, below.
* Function Codes Off
Function Codes On
Telepen
<Default All Telepen Settings>
Telepen
On
* Off
Telepen Output
Using AIM Telepen Output, the scanner reads symbols with start/stop pattern 1
and decodes them as standard full ASCII (start/stop pattern 1). When Original
Telepen Output is selected, the scanner reads symbols with start/stop pattern 1
and decodes them as compressed numeric with optional full ASCII (start/stop
pattern 2). Default = AIM Telepen Output.
Original Telepen Output
IT5600/IT5800 User’s Guide
7 - 17
Download from Www.Somanuals.com. All Manuals Search And Download.
Telepen Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 1-60. Minimum Default = 1, Maximum Default = 60.
Minimum Message Length
Maximum Message Length
UPC A
<Default All UPC A Settings>
UPC A
* On
Off
UPC A Check Digit
This selection allows you to specify whether the check digit should be transmitted
at the end of the scanned data or not. Default = On.
* On
Off
UPC A Number System
7 - 18
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC A, continued
UPC A Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC A data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
UPC A Addenda Required
When Addenda Required is set to on, the scanner will only read UPC A bar
codes that have addenda. Default = Not Required.
Required
* Not Required
UPC A Addenda Separator
When this feature is on, there is a space between the data from the bar code and
the data from the addenda. When turned off, there is no space.
Default = On.
* On
Off
7 - 20
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC-A/EAN-13 with Extended Coupon Code
Use the following codes to enable or disable UPC-A and EAN-13 with Extended
Coupon Code. Default = On.
* On
Off
UPC E
<Default All UPC E Settings>
UPC E0 and UPC E1
Most U.P.C. bar codes lead with the 0 number system. For these codes, use the
UPC E0 selection. If you need to read codes that lead with the 1 number system,
use the UPC E1 selection. Default = On (UPC E0) and Off (UPC E1).
* UPC E0 On
UPC E0 Off
* UPC E1 On
UPC E1 Off
IT5600/IT5800 User’s Guide
7 - 21
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC E, continued
UPC E0 and UPC E1 Expand
UPC E Expand expands the UPC E code to the 12 digit, UPC A format.
Default = Off.
On
* Off
UPC E0 and UPC E1 Addenda Required
When Addenda Required is set to on, the scanner will only read UPC E bar
codes that have addenda. Default = Not Required.
Required
* Not Required
UPC E0 and UPC E1 Addenda Separator
When this feature is on, there is a space between the data from the bar code and
the data from the addenda. When turned off, there is no space.
Default = On.
* On
Off
7 - 22
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
UPC E, continued
UPC E0 Check Digit
Check Digit specifies whether the check digit should be transmitted at the end of
the scanned data or not. Default = On.
* On
Off
UPC E0 Number System
The numeric system digit of a U.P.C. symbol is normally transmitted at the
beginning of the scanned data, but the unit can be programmed so it will not
transmit it. Default = On.
* On
Off
UPC E0 Addenda
This selection adds 2 or 5 digits to the end of all scanned UPC E data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
IT5600/IT5800 User’s Guide
7 - 23
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN 13
EAN/JAN 13
<Default All EAN/JAN Settings>
* On
Off
EAN/JAN 13 Check Digit
This selection allows you to specify whether the check digit should be transmitted
at the end of the scanned data or not. Default = On.
* On
Off
EAN/JAN 13 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 13 data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
7 - 24
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN 13, continued
EAN/JAN 13 Addenda Required
When Addenda Required is set to on, the scanner will only read EAN/JAN 13 bar
codes that have addenda. Default = Not Required.
Required
* Not Required
EAN/JAN 13 Addenda Separator
When this feature is on, there is a space between the data from the bar code and
the data from the addenda. When turned off, there is no space.
Default = On.
* On
Off
Note: If you want to enable or disable EAN13 with Extended Coupon Code,
refer to UPC-A/EAN-13 with Extended Coupon Code on page 7-21.
ISBN Translate
This selection causes EAN-13 Bookland symbols to be translated into their
equivalent ISBN number format. Default = Off.
On
* Off
IT5600/IT5800 User’s Guide
7 - 25
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN 8
EAN/JAN 8
<Default All EAN/JAN 8 Settings>
* On
Off
EAN/JAN 8 Check Digit
This selection allows you to specify whether the check digit should be transmitted
at the end of the scanned data or not. Default = On.
* On
Off
EAN/JAN 8 Addenda
This selection adds 2 or 5 digits to the end of all scanned EAN/JAN 8 data.
Default = Off for both 2 Digit and 5 Digit Addenda.
2 Digit Addenda On
* 2 Digit Addenda Off
5 Digit Addenda On
* 5 Digit Addenda Off
7 - 26
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
EAN/JAN 8, continued
EAN/JAN 8 Addenda Required
When Addenda Required is set to on, the scanner will only read EAN/JAN 8 bar
codes that have addenda. Default = Not Required.
Required
* Not Required
EAN/JAN 8 Addenda Separator
When this feature is on, there is a space between the data from the bar code and
the data from the addenda. When turned off, there is no space.
Default = On.
* On
Off
MSI
<Default All MSI Settings>
MSI
On
* Off
IT5600/IT5800 User’s Guide
7 - 27
Download from Www.Somanuals.com. All Manuals Search And Download.
MSI, continued
MSI Check Character
Different types of check characters are used with MSI bar codes. You can
program the scanner to read MSI bar codes with Type 10 check characters.
Default = Validate Type 10, but Don’t Transmit.
When Check Character is set to Validate and Transmit, the scanner will only
read MSI bar codes printed with the specified type check character, and will
transmit this character at the end of the scanned data.
When Check Character is set to Validate, but Don’t Transmit, the unit will only
read MSI bar codes printed with the specified type check character, but will not
transmit the check character with the scanned data.
Transmit
Validate Type 10 and Transmit
MSI Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 4-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 28
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Plessey Code
Plessey Code
<Default All Plessey Code Settings>
On
* Off
Plessey Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 4-48. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
RSS-14
< Default All RSS-14 Settings >
IT5600/IT5800 User’s Guide
7 - 29
Download from Www.Somanuals.com. All Manuals Search And Download.
RSS Expanded, continued
RSS Expanded
* On
Off
RSS Expanded Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 4-74. Minimum Default = 4, Maximum Default = 74.
Minimum Message Length
Maximum Message Length
EAN•UCC Emulation
The imager can automatically format the output from any EAN•UCC data carrier
to emulate what would be encoded in an equivalent UCC/EAN-128 or
RSS+Composite symbol. EAN•UCC data carriers include UPC-A and UPC-E,
EAN-13 and EAN-8, ITF-14, UCC/EAN-128, and EAN•UCC RSS and
Composites. If UCC/EAN-128 Emulation is selected, the AIM Symbology
Identifier will be reported as “]C1”. If RSS Emulation is selected, the AIM
Symbology Identifier will be reported as “]e0.” Any application that accepts
EAN•UCC data can be simplified since it only needs to recognize one data carrier
type. Default = EAN•UCC Emulation Off.
RSS Emulation
128 Emulation
* EAN•UCC Emulation Off
IT5600/IT5800 User’s Guide
7 - 31
Download from Www.Somanuals.com. All Manuals Search And Download.
China Post Code
<Default All China Post Code Settings>
China Post Code
On
* Off
China Post Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 2-80. Minimum Default = 4, Maximum Default = 80.
Minimum Message Length
Maximum Message Length
7 - 32
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Korea Post Code
<Default All Korea Post Code Settings>
Korea Post Code
On
* Off
Korea Post Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 2-80. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
IT5600/IT5800 User’s Guide
7 - 33
Download from Www.Somanuals.com. All Manuals Search And Download.
PosiCode
<Default All PosiCode Settings>
PosiCode A and B
* On
Off
You have to have PosiCode A and B on to read any of the PosiCode
symbologies.
A and B On
(No Limited)
A and B and Limited A On
(Limited B Off)
* A and B and Limited B On
(Limited A Off)
PosiCode Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 2-80. Minimum Default = 4, Maximum Default = 48.
Minimum Message Length
Maximum Message Length
7 - 34
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Trioptic Code
Trioptic Code is used for labeling magnetic storage media.
Note: If you are going to scan Code 32 Pharmaceutical codes, Trioptic Code
must be off.
On
* Off
Codablock F
<Default All Codablock F Settings>
Codablock F
On
* Off
Codablock F Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 1-2048. Minimum Default = 1, Maximum Default = 2048.
Minimum Message Length
Maximum Message Length
IT5600/IT5800 User’s Guide
7 - 35
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 16K
Code 16K
<Default All Code 16K Settings>
On
* Off
Code 16K Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 0-160. Minimum Default = 1, Maximum Default = 160.
Minimum Message Length
Maximum Message Length
Code 49
<Default All Code 49 Settings>
7 - 36
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Code 49
* On
Off
Code 49 Message Length
Scan the bar codes below to change the message length. Refer to Message
Length on page 7-2 for additional information. Minimum and Maximum
lengths = 1-81. Minimum Default = 1, Maximum Default = 81.
Minimum Message Length
Maximum Message Length
IT5600/IT5800 User’s Guide
7 - 37
Download from Www.Somanuals.com. All Manuals Search And Download.
7 - 38
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
8
Interface Keys
Keyboard Function Relationships
The following Keyboard Function Code, Hex/ASCII Value, and Full ASCII
“CTRL”+ relationships apply to all terminals that can be used with the scanner.
Refer to page 2-6 enable Control + ASCII mode.
Function Code
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HEX/ASCII Value
Full ASCII “CTRL” +
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
2
A
B
C
D
E
F
G
H
I
HT
LF
J
VT
K
L
FF
CR
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
SUB
ESC
FS
\
GS
]
RS
6
US
-
IT5600/IT5800 User’s Guide
8 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
The last five characters in the Full ASCII “CTRL”+ column ( [ \ ] 6 - ), apply to US
only. The following chart indicates the equivalents of these five characters for
different countries.
Country
United States
Belgium
Codes
[
[
\
<
<
8
Ã
\
]
]
6
6
6
6
6
6
6
6
6
6
6
-
-
Scandinavia
France
8
^
9
$
+
+
. .
]
-
=
-
Germany
Italy
-
Switzerland
United Kingdom
Denmark
Norway
<
¢
\
-
[
8
8
[
-
9
9
]
-
\
-
Spain
\
-
8 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Interface Keys
IBM AT/XT and
PS/2 Compatibles,
WYSE PC/AT
IBM XTs and
Compatibles
IBM, DDC, Memorex
Telex, Harris*
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Supported Keys
Reserved
Enter (KP)
Cap Lock
ALT make
ALT break
CTRL make
CTRL break
CR/Enter
Reserved
Tab
Supported Keys Supported Keys
Reserved
CR/Enter
Caps Lock
Reserved
Reserved
Reserved
Reserved
CR/Enter
Reserved
Tab
Reserved
Enter
F11
F12
F13
F14
F15
New Line
F16
HT
F17
LF
Reserved
Tab
Reserved
Tab
F18
VT
Tab/Field Forward
FF
Delete
CR/Enter
Insert
Delete
CR/Enter
Insert
Delete
CR
Field Exit/New Line
SO
Insert
SI
Escape
F11
Escape
Reserved
Home
F19
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
Error Reset
Home
Home
Print
Print
F20
Back Space
Back Tab
F12
Back Space
Back Tab
Reserved
F1
Back Space
Backfield/Back Tab
F21
F1
F2
F3
F4
F5
F6
F7
F8
F9
F10
F1
F2
F2
F3
F3
F4
F4
SUB
ESC
FS
F5
F5
F6
F6
F7
GS
F8
F8
RS
F9
F9
US
F10
F10
* IBM 3191/92, 3471/72, 3196/97, 3476/77, Telex (all models)
IT5600/IT5800 User’s Guide
8 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Interface Keys
IBM, Memorex Telex (102)* Memorex Telex (88)**
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Supported Keys
Supported Keys
Reserved
Enter
Reserved
Enter
F11
PF10
F12
PF11
F13
PF12
F14
Reserved
Reserved
New Line
Field Forward
Field Forward
Reserved
Field Forward
Delete
F15
New Line
F16
HT
F17
LF
F18
VT
Tab/Field Forward
Delete
Field Exit
Insert
Clear
Error Reset
Home
Print
FF
CR
New Line
Insert
SO
SI
Erase
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
Error Reset
Reserved
Print
Back Space
Back Tab
F19
Back Space
Back Field
Reserved
PF1
F1
F2
PF2
F3
PF3
F4
PF4
SUB
ESC
FS
F5
PF5
F6
PF6
F7
PF7
GS
F8
PF8
RS
F9
PF9
US
F10
Home
* IBM 3196/97, 3476/77, 3191/92, 3471/72, Memorex Telex (all models) with 102
key keyboards
** Memorex Telex with 88 key keyboards
8 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Interface Keys
Esprit 200, 400
ANSI
Esprit 200, 400
ASCII
Esprit 200, 400
PC
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
Supported Keys
Reserved
New Line
N/A
Supported Keys
Supported Keys
Reserved
New Line
N/A
Reserved
New Line
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
N/A
New Line
N/A
New Line
N/A
New Line
N/A
HT
Tab
Tab
Tab
LF
N/A
N/A
N/A
VT
Tab
Tab
Tab
FF
N/A
N/A
Delete
New Line
Insert
Escape
F11
CR
New Line
N/A
New Line
N/A
SO
SI
Escape
F11
Escape
F11
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
Insert
F13
Insert
F13
Home
Print
Back Space
Back Tab
F12
Back Space
Back Tab
F12
Back Space
Back Tab
F12
F1
F1
F1
F2
F2
F2
F3
F3
F3
F4
F4
F4
SUB
ESC
FS
F5
F5
F5
F6
F6
F6
F7
F7
F7
GS
F8
F8
RS
F9
F9
F9
US
F10
F10
F10
IT5600/IT5800 User’s Guide
8 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Supported Interface Keys
Apple Mac/iMac
ASCII
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
HEX
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
7F
Supported Keys
Reserved
Enter/Numpad Enter
CAPS
ALT make
ALT break
CNTRL make
CNTRL break
RETURN
APPLE make
TAB
HT
LF
APPLE break
TAB
VT
FF
Del
CR
RETURN
Ins Help
ESC
SO
SI
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
F11
Home
Prnt Scrn
BACKSPACE
LSHIFT TAB
F12
F1
F2
F3
F4
SUB
ESC
FS
F5
F6
F7
GS
F8
RS
F9
US
F10
DEL
BACKSPACE
8 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
9
Utilities
To Add a Test Code I.D. Prefix to All Symbologies
This selection allows you to turn on transmission of a Code I.D. before the
decoded symbology. (See the Symbology Chart, included in the Appendix
A, page A-1) for the single character code that identifies each symbology.) This
action first clears all current prefixes, then programs a Code I.D. prefix for all
symbologies. This is a temporary setting that will be removed when the unit is
power cycled.
Add Code I.D. Prefix to
All Symbologies (Temporary)
Show Software Revision
Scan the bar code below to output the current software revision, unit serial
number, and other product information.
Show Revision
Show Data Format
Scan the bar code below to show current data format settings.
Data Format Settings
If you aren’t sure what programming options are in your scanner, or you’ve
changed some options and want the standard product default settings restored,
scan the Standard Product Default Settings bar code below.
Standard Product Default Settings
The Menu Commands starting on page 11-5 lists the standard product default
settings for each of the commands (indicated by an asterisk (*) on the
programming pages).
IT5600/IT5800 User’s Guide
9 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Temporary Visual Menu 2003 Configuration
For quick download communication configuration, scan the Visual Menu 2003
bar code to temporarily configure the scanner for Visual Menu 2003 settings.
Refer to Visual Menu 2003 on page 10-1 for additional information about Visual
Menu 2003.
Note: If you have a unit capable of keyboard wedge mode, scan the bar code
below and the unit will communicate in RS-232 mode, allowing it to work
communication, cycle the power.
Visual Menu 2003
Note: If you download new software into a unit, the user-programmed
parameters are retained. If you need to discard user-programmed
settings, scan the Standard Product Default Settings bar code (see
Standard Product Default Settings on page 9-1).
9 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
10
Visual Menu 2003
Visual Menu 2003 Introduction
Visual Menu 2003 provides the ability to configure a scanning device by
connecting the scanner to the com port of a PC. Visual Menu 2003 allows you
to download updates to a scanner’s firmware, change programmed parameters,
and create and print programming bar codes. Using Visual Menu 2003, you can
even set up the configuration for a scanner which is not attached to your PC.
This enables one expert user to establish the configuration settings for all the
devices your company uses, then save these configuration files for others. A
configuration file can be e-mailed or, if you prefer, an expert user can create a
bar code (or series of bar codes) that contains all the customized programming
parameters, and mail or fax the bar code(s) to any location. Users in other
locations can scan the bar code(s) to load in the customized parameters.
To communicate with a scanner, Visual Menu 2003 requires that the PC have at
least one available serial communication port and an RS-232 cable to connect
the port to the device. A power supply, which plugs into the cable, is also
required.
Note: If you already have a copy of Visual Menu, please note that older versions
of Visual Menu will not work with the IT5600/5800. You must use Visual
Menu 2003 with the IT5600/5800.
Visual Menu 2003 Operations
The Visual Menu 2003 program performs the following operations:
•
•
Displays all configuration data, and saves the information to a file on your PC.
Configures the device to meet your specific requirements. Visual Menu 2003
has all the programming parameters which are available via programming bar
codes in this User’s Guide.
•
•
Creates and prints a clone bar code which contains the program and
configuration data from one device. This bar code can then be used to
program additional devices with the same parameters.
Selects a device from a list, then performs offline or online file configuration
for that device.
Installing Visual Menu 2003 from the Web
2. Click in the Quick Search text box and enter Visual Menu 2003.
3. Click on Search Now.
4. Click on the entry for Visual Menu 2003.
5. When prompted, select Save File, and save the files to the
c:\windows\temp directory.
IT5600/IT5800 User’s Guide
10 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
6. Once you have finished downloading the file, exit the web site.
7. Using Explorer, go to the c:\windows\temp file.
8. Double click on the Visualmenu2003.exe file. Follow the screen prompts to
install the Visual Menu 2003 program.
9. To start Visual Menu 2003, from the Start Menu click on Programs, Visual
Menu2003, Visual Menu2003.
Note: If you wish, you can create a shortcut to the Visual Menu 2003 executable
on your desktop.
10 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
11
Serial Programming Commands
The serial programming commands can be used in place of the programming bar
codes. Both the serial commands and the programming bar codes will program
the IT5600/5800. For complete descriptions and examples of each serial
programming command, refer to the corresponding programming bar code in
this manual.
The device must be set to an RS-232 interface (see page 1-7). The following
commands can be sent via a PC com port using terminal emulation software.
Conventions
The following conventions are used for menu and query command descriptions:
parameterA label representing the actual value you should send as part of a
command.
[option] An optional part of a command.
{Data} Alternatives in a command.
bold
Names of menus, menu commands, buttons, dialog boxes, and
windows that appear on the screen.
Menu Command Syntax
Menu commands have the following syntax (spaces have been used for clarity
only):
Prefix Tag SubTag {Data} [, SubTag {Data}] [; Tag SubTag {Data}] […] Storage
Prefix
Tag
Three ASCII characters: SYN M CR (ASCII 22,77,13).
A 3 character case-insensitive field that identifies the desired menu
command group. For example, all RS-232 configuration settings
are identified with a Tag of 232.
SubTag
A 3 character case-insensitive field that identifies the desired menu
command within the tag group. For example, the SubTag for the
RS-232 baud rate is BAD.
Data
The new value for a menu setting, identified by the Tag and Sub-
Tag.
Storage
A single character that specifies the storage table to which the
mand’s operation on the device’s volatile menu configuration table.
A period (.) performs the command’s operation on the device’s
non-volatile menu configuration table. Use the non-volatile table
only for semi-permanent changes you want saved through a power
cycle.
IT5600/IT5800 User’s Guide
11 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Query Commands
Several special characters can be used to query the device about its settings.
^
?
*
What is the default value for the setting(s).
What is the device’s current value for the setting(s).
What is the range of possible values for the setting(s). (The de-
vice’s response uses a dash (-) to indicate a continuous range of
values. A pipe (|) separates items in a list of non-continuous val-
ues.)
Tag Field Usage
When a query is used in place of a Tag field, the query applies to the entire set
of commands available for the particular storage table indicated by the Storage
field of the command. In this case, the SubTag and Data fields should not be
used because they are ignored by the device.
SubTag Field Usage
When a query is used in place of a SubTag field, the query applies only to the
subset of commands available that match the Tag field. In this case, the Data
field should not be used because it is ignored by the device.
Data Field Usage
When a query is used in place of the Data field, the query applies only to the
specific command identified by the Tag and SubTag fields.
Concatenation of Multiple Commands
Multiple commands can be issued within one Prefix/Storage sequence. Only the
Tag, SubTag, and Data fields must be repeated for each command in the
sequence. If additional commands are to be applied to the same Tag, then the
new command sequence is separated with a comma (,) and only the SubTag and
Data fields of the additional command are issued. If the additional command
requires a different Tag field, the command is separated from previous
commands by a semicolon (;).
Responses
The device responds to serial commands with one of three responses:
ACK Indicates a good command which has been processed.
ENQ Indicates an invalid Tag or SubTag command.
NAK Indicates the command was good, but the Data field entry was out of the
allowable range for this Tag and SubTag combination, e.g., an entry for a
minimum message length of 100 when the field will only accept 2
characters.
11 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
When responding, the device echoes back the command sequence with the
status character inserted directly before each of the punctuation marks (the
period, exclamation point, comma, or semicolon) in the command.
Examples of Query Commands
In the following examples, a bracketed notation [ ] depicts a non-displayable
response.
Example: Example #1:What is the range of possible values for Codabar
Coding Enable?
Enter:
cbrena*.
Response: CBRENA0-1[ACK]
This response indicates that Codabar Coding Enable (CBRENA) has a range of
values from 0 to 1 (off and on).
Example: Example #2: What is the default value for Codabar Coding Enable?
Enter:
cbrena^.
Response: CBRENA1[ACK]
This response indicates that the default setting for Codabar Coding Enable
(CBRENA) is 1, or on.
Example: Example #3: What is the device’s current setting for Codabar
Coding Enable?
Enter:
cbrena?.
Response: CBRENA1[ACK]
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on.
Example: Example #4: What are the device’s settings for all Codabar
selections?
Enter:
cbr?.
Response: CBRENA1[ACK],
SSX0[ACK],
CK20[ACK],
CCT1[ACK],
MIN2[ACK],
MAX60[ACK],
DFT[ACK].
This response indicates that the device’s Codabar Coding Enable (CBRENA) is
set to 1, or on;
the Start/Stop Character (SSX) is set to 0, or Don’t Transmit;
the Check Character (CK2) is set to 0, or Not Required;
concatenation (CCT) is set to 1, or Enabled;
the Minimum Message Length (MIN) is set to 2 characters;
the Maximum Message Length (MAX) is set to 60 characters;
and the Default setting (DFT) has no value.
IT5600/IT5800 User’s Guide
11 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Trigger Commands
You can activate and deactivate the scanner with serial trigger commands.
First, the scanner must be put in Manual/Serial Trigger Mode either by scanning
Serial Menu Command (page 11-8). Once the scanner is in serial trigger mode,
the trigger is activated and deactivated by sending the following commands:
Activate:SYN T CR
Deactivate:SYN U CR
The scanner scans until a bar code has been read, until the deactivate com-
mand is sent, or until the serial time-out has been reached (see Read Time-
Out on page 3-4 for a description, and the serial command on page 11-8).
Resetting the Standard Product Defaults
If you aren’t sure what programming options are in your scanner, or you’ve
changed some options and want the factory settings restored, scan the
Standard Product Default Settings bar code below.
Standard Product Default Settings
The chart on the following pages lists the factory default settings for each of the
menu commands (indicated by an asterisk (*) on the programming pages).
11 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Menu Commands
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Factory Default Settings
Default
DEFALT
Terminal Interfaces
003 (5600SR010 and
56/5800SR050 models)
000 (5600SR030 and 000
models)
2-2
Terminal ID
TERMID###
*USA
KBDCTY0
KBDCTY1
KBDCTY8
KBDCTY2
KBDCTY3
KBDCTY4
KBDCTY7
KBDCTY5
KBDCTY9
KBDCTY10
KBDCTY6
KBDSTY0
KBDSTY1
KBDSTY2
KBDSTY6
2-4
2-4
2-4
2-4
2-4
2-4
2-4
2-4
2-4
2-4
2-4
2-5
2-5
2-5
2-5
Belgium
Denmark
Finland
France
Program Keyboard Country
Germany/Austria
Great Britain
Italy
Norway
Spain
Switzerland
*Regular
Caps Lock
Shift Lock
Automatic Caps Lock
Keyboard Style
Emulate External
Keyboard
KBDSTY5
2-6
*Control + ASCII Off
Control + ASCII On
*Turbo Mode Off
KBDCAS0
KBDCAS1
KBDTMD0
KBDTMD1
KBDNPS0
KBDNPS1
KBDADC0
KBDADC1
PAP232
2-6
2-6
2-6
2-6
2-6
2-6
2-7
2-7
2-8
Turbo Mode On
Keyboard Modifiers
*Numeric Keypad Off
Numeric Keypad On
*Auto Direct Conn. Off
Auto Direct Conn. On
RS-232
Serial Port Connection
IT5600/IT5800 User’s Guide
11 - 5
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
300 BPS
232BAD0
232BAD1
232BAD2
232BAD3
232BAD4
232BAD5
232BAD6
232BAD7
232BAD8
232BAD9
2-9
2-9
2-9
2-9
2-9
2-9
2-9
2-9
2-9
2-9
600 BPS
1200 BPS
2400 BPS
4800 BPS
9600 BPS
19200 BPS
38400 BPS
57600 BPS
*115200 BPS
Baud Rate
7 Data, 1 Stop, Parity Even
2-10
232WRD3
7 Data, 1 Stop, Parity None
7 Data, 1 Stop, Parity Odd
7 Data, 2 Stop, Parity Even
7 Data, 2 Stop, Parity None
7 Data, 2 Stop, Parity Odd
8 Data, 1 Stop, Parity Even
*8 Data, 1 Stop, Parity None
8 Data, 1 Stop, Parity Odd
*RTS/CTS Off
232WRD0
232WRD6
232WRD4
232WRD1
232WRD7
232WRD5
232WRD2
232WRD8
232CTS0
232CTS1
232XON0
232XON1
232ACK0
232ACK1
TERMID64
TERMID61
2-10
2-10
2-10
2-10
2-10
2-10
2-10
2-10
2-11
2-11
2-11
2-11
2-11
2-11
2-11
2-11
Word Length: Data Bits,
Stop Bits, and Parity
RTS/CTS On
*XON/XOFF Off
RS-232 Handshaking
XON/XOFF On
*ACK/NAK Off
ACK/NAK On
Same Code Format
Code 39 Format
Wand Emulation Connec-
tion
11 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
10
WNDSPD0
WNDSPD1
WNDSPD2
WNDSPD3
WNDSPD4
WNDSPD5
WNDSPD6
WNDPOL0
WNDPOL1
WNDIDL0
WNDIDL1
WNDBLK0
WNDBLK1
WNDBLK2
WNDBLK3
WNDDLY0
WNDDLY1
WNDDLY2
WNDDLY3
2-12
2-12
2-12
2-12
2-12
2-12
2-12
2-12
2-12
2-13
2-13
2-13
2-13
2-13
2-13
2-14
2-14
2-14
2-14
*25
40
Wand Emulation Transmis-
sion Rate
80
120
150
200
*Black High
White High
Idle Low
*Idle High
20
Wand Emulation Polarity
Wand Emulation Idle
*40
Wand Emulation Data
Block Size
60
80
5ms
*50ms
150ms
500ms
Wand Emulation Delay
Between Blocks
Wand Emulation Overall
Checksum
*Off
On
WNDCHK0
WNDCHK1
2-14
2-14
Output Selections
Off
BEPBEP0
BEPBEP1
BEPLVL0
3-1
3-1
3-1
3-1
3-1
3-1
3-1
3-1
3-1
Beeper - Good Read
*On
Off
Low
BEPLVL1
Beeper Volume - Good
Read
Medium (Default for IT5600)
High (Default for IT5800)
Low (1600) (min 400Hz)
*Medium (3250)
High (4200) (max 9000Hz)
BEPLVL2
BEPLVL3
BEPFQ11600
BEPFQ13250
BEPFQ14200
Beeper Pitch - Good Read
(Frequency)
IT5600/IT5800 User’s Guide
11 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
*Normal Beep
Short Beep
Off
BEPBIP0
3-2
3-2
3-2
3-2
3-2
3-2
3-3
3-3
3-3
3-3
Beeper Duration - Good
Read
BEPBIP1
BEPLED0
BEPLED1
BEPRPT1
BEPRPT#
DLYGRD0
DLYGRD500
DLYGRD1000
DLYGRD1500
LED - Good Read
*On
*1
Number of Beeps - Good
Read
Range 1 - 9
*No Delay
Short Delay (500 ms)
Medium Delay (1000 ms)
Long Delay (1500 ms)
Good Read Delay
User-Specified Good Read
Delay
DLYGRD####
#
Range 0 - 30,000 ms
*Manual/Serial Trigger
3-3
3-3
3-4
3-4
3-4
TRGMOD0
TRGSTO####
TRGMOD2
TRGLPT###
Read Time-Out (0 - 300,000
ms) *300,000
Manual Trigger, Low Power
Low Power Time-Out (0 - 300
seconds) *120
Trigger Mode
Automatic Trigger
Presentation Mode
TRGMOD1
TRGMOD3
3-4
3-5
Hands Free Time-Out (0-
300,000 seconds) *5000
TRGPTO####
##
3-5
Short (500 ms)
DLYRRD500
DLYRRD750
DLYRRD1000
DLYRRD3000
3-6
3-6
3-6
3-6
*Medium (750 ms)
Long (1000 ms)
Reread Delay
Extra Long (2000 ms)
User-Specified Reread
Delay
DLYRRD####
#
Range 0 - 30,000 ms
3-6
1 second
SCNDLY1000
SCNDLY2000
SCNDLY0
3-7
3-7
3-7
3-7
3-7
3-7
2 seconds
Aimer Delay
Aimer Mode
*Off (no delay)
Delay Duration (0 - 4000ms)
SCNDLY####
SCNAIM0
Off
*On
SCNAIM2
11 - 8
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Time-Out Duration (0 -
240,000 ms) *0
SCNADR####
##
Aimer Beam Time-Out
3-8
Centering On
DECWIN1
DECWIN0
DECLFT###
DECRGT###
SEQBLK
3-8
*Centering Off
3-8
Centering
Left of Centering Window *40
3-8
Right of Centering Window *60
3-8
Enter Sequence
3-11
3-11
3-11
3-11
3-11
3-14
3-14
3-13
3-13
3-13
3-13
Output Sequence Editor
Require Output Sequence
Default Sequence
SEQDFT
Required
SEQ_EN2
SEQ_EN1
SEQ_EN0
SHOTGN1
SHOTGN0
SHWNRD1
SHWNRD0
VIDREV1
On/Not Required
*Off
On
Multiple Symbols
No Read
*Off
On
*Off
On
Video Reverse
*Off
VIDREV0
Prefix/Suffix Selections
Add CR Suffix to All Symbologies
VSUFCR
4-3
4-3
4-3
4-3
4-4
4-4
4-4
4-4
4-4
4-5
4-5
4-5
4-6
4-6
Add Prefix
PREBK2##
PRECL2
Prefix
Suffix
Clear One Prefix
Clear All Prefixes
Add Suffix
PRECA2
SUFBK2##
SUFCL2
Clear One Suffix
Clear All Suffixes
*Enable
SUFCA2
RMVFNC0
RMVFNC1
DLYCHR##
DLYCRX##
DLY_XX###
DLYFNC##
DLYMSG##
Function Code Transmit
Intercharacter Delay
Disable
Delay Length
User Specified Intercharac-
ter Delay
Character to Trigger Delay
Interfunction Delay
Intermessage Delay
IT5600/IT5800 User’s Guide
11 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Data Formatter Selections
*Default Data Format (None)
DFMDF3
DFMBK3##
DFMCL3
DFMCA3
DFM_EN0
DFM_EN1
DFM_EN2
VSAF_1
5-4
5-4
5-4
5-4
5-5
5-5
5-5
5-5
5-5
5-5
Enter Data Format
Data Format Editor
Clear One Data Format
Clear All Data Formats
Off
Data Formatter
*On, but Not Required
On, Required
1
2
3
Alternate Data Formats
VSAF_2
VSAF_3
Secondary Interface Selections
*Disable
2IF_EN0
2IF_EN1
6-2
6-2
Enabling the Secondary
Interface
Enable
Secondary RS-232 Con-
nection
RS-232 Interface
2IFTYP0
6-2
Same Code Format
Code 39 Format
2IFTYP64
2IFTYP61
6-2
6-2
Secondary Code 39 Wand
Emulation
*Laser Emulation Same Code
Output
PAPHLC
PAP088
PAP087
6-3
6-3
6-3
Secondary Laser Emula-
tion
Laser Emulation Raw Output
Laser Emulation Code 39
Output
*36
HLCSPD0
HLCSPD1
HLCPOL0
HLCPOL1
HLCIDL0
HLCIDL1
2IFTRG0
2IFTRG1
2IFTRG3
2IFTRG2
2IFLPT###
6-3
6-3
6-4
6-4
6-4
6-4
6-4
6-4
6-4
6-5
6-5
Laser Emulation Transmis-
sion Rate
100
Black High
Laser Emulation Polarity
Laser Emulation Idle
*White High
Low
*High
*Manual Trigger
Automatic Trigger
Presentation Mode
Manual Trigger, Low Power
Low Power Time-Out *120
Secondary Trigger Mode
11 - 10
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Symbologies
All Symbologies Off
All Symbologies On
ALLENA0
ALLENA1
7-1
7-1
All Symbologies
Default All Codabar
Settings
Codabar
Codabar
CBRDFT
7-3
Off
CBRENA0
CBRENA1
CBRSSX0
CBRSSX1
CBRCK20
CBRCK21
CBRCK22
CBRCCT0
CBRCCT1
CBRCCT2
CBRMIN##
CBRMAX##
7-3
7-3
7-3
7-3
7-4
7-4
7-4
7-4
7-4
7-4
7-5
7-5
*On
*Don’t Transmit
Transmit
Codabar Start/Stop Char.
Codabar Check Char.
*No Check Char.
Validate, But Don’t Transmit
Validate, and Transmit
Off
Codabar Concatenation
*On
Require
Minimum (2 - 60) *4
Maximum (2 - 60) *60
Codabar Message Length
Code 39
Default All Code 39
Settings
C39DFT
7-5
Off
C39ENA0
C39ENA1
C39SSX0
C39SSX1
C39CK20
7-5
7-5
7-5
7-5
7-6
Code 39
*On
*Don’t Transmit
Transmit
Code 39 Start/Stop Char.
Code 39 Check Char.
*No Check Char.
Validate, But Don’t
Transmit
C39CK21
C39CK22
7-6
7-6
Validate,
and Transmit
Minimum (0 - 48) *0
C39MIN##
C39MAX##
C39APP0
C39APP1
C39B320
C39B321
7-6
7-6
7-7
7-7
7-8
7-8
Code 39 Message Length
Code 39 Append
Maximum (0 - 48) *48
*Off
On
*Off
On
Code 32 Pharmaceutical
(PARAF)
IT5600/IT5800 User’s Guide
11 - 11
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Off
C39ASC0
C39ASC1
7-8
7-8
Code 39 Full ASCII
Interleaved 2 of 5
Interleaved 2 of 5
*On
Default All Interleaved
2 of 5 Settings
I25DFT
7-9
Off
I25ENA0
I25ENA1
I25CK20
7-9
*On
7-9
*No Check Char.
7-10
Interleaved 2 of 5 Check
Digit
Validate, But Don’t
Transmit
I25CK21
7-10
Validate, and Transmit
Minimum (2 - 80) *4
Maximum (2 - 80) *80
I25CK22
7-10
7-10
7-10
I25MIN##
I25MAX##
Interleaved 2 of 5 Message
Length
Default All Code 93
Settings
Code 93
Code 93
C93DFT
7-11
Off
C93ENA0
C93ENA1
C93MIN##
C93MAX##
7-11
7-11
7-11
7-11
*On
Minimum (0 - 80) *0
Maximum (0 - 80) *80
Code 93 Message Length
Code 2 of 5
Default All Code 2 of 5
Settings
R25DFT
7-12
*Off
R25ENA0
R25ENA1
R25MIN##
R25MAX##
7-12
7-12
7-12
7-12
Code 2 of 5
On
Minimum (1 - 48) *4
Maximum (1 - 48) *48
Code 2 of 5 Message
Length
Default All IATA Code 2 of 5
Settings
IATA Code 2 of 5
IATA Code 2 of 5
A25DFT
7-13
*Off
A25ENA0
A25ENA1
A25MIN##
A25MAX##
7-13
7-13
7-13
7-13
On
Minimum (1 - 48) *4
Maximum (1 - 48) *48
IATA Code 2 of 5 Message
Length
Default All Matrix 2 of 5
Settings
Matrix 2 of 5
Matrix 2 of 5
X25DFT
7-13
*Off
On
X25ENA0
X25ENA1
7-13
7-13
11 - 12
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Minimum (1 - 80) *4
Maximum (1 - 80) *80
X25MIN##
X25MAX##
7-14
7-14
Matrix 2 of 5 Message
Length
Default All Code 11
Settings
Code 11
Code 11
C11DFT
7-14
*Off
C11ENA0
C11ENA1
C11CK20
C11CK21
C11MIN##
C11MAX##
7-14
7-14
7-14
7-14
7-15
7-15
On
1 Check Digit
*2 Check Digits
Minimum (1 - 80) *4
Maximum (1 - 80) *80
Code 11 Check Digits
Required
Code 11 Message Length
Code 128
Default All Code 128
Settings
128DFT
7-15
Off
128ENA0
128ENA1
ISBENA1
ISBENA0
128MIN##
128MAX##
128DCP
7-16
7-15
7-16
7-16
7-16
7-16
7-16
7-17
7-17
7-16
7-16
Code 128
*On
On
ISBT Concatenation
*Off
Minimum (0 - 80) *0
Code 128 Message Length
Code 128 Code Page
Maximum (0 - 80) *80
Code 128 Code Page
*Off
On
128FNX0
128FNX1
ISBENA0
ISBENA1
Code 128 Function Code
Transmit
*Off
On
ISBT Concatenation
Telepen
Default All Telepen
Settings
TELDFT
7-17
*Off
TELENA0
TELENA1
TELOLD0
TELOLD1
TELMIN##
TELMAX##
7-17
7-17
7-17
7-17
7-18
7-18
Telepen
On
*AIM Telepen Output
Original Telepen Output
Minimum (1 - 60) *1
Maximum (1 - 60) *60
Telepen Output
Telepen Message Length
UPC A
Default All
UPC A Settings
UPADFT
7-18
IT5600/IT5800 User’s Guide
11 - 13
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Off
UPAENA0
UPAENA1
UPACKX0
UPACKX1
UPANSX0
UPANSX1
UPAAD20
UPAAD21
UPAAD50
UPAAD51
UPAARQ0
UPAARQ1
UPAADS0
UPAADS1
7-18
7-18
7-18
7-18
7-19
7-19
7-20
7-20
7-20
7-20
7-20
7-20
7-20
7-20
UPC A
*On
Off
UPC A Check Digit
UPC A Number System
UPC A 2 Digit Addenda
UPC A 5 Digit Addenda
UPC A Addenda Required
*On
Off
*On
*Off
On
*Off
On
*Not Required
Required
Off
UPC A Addenda
Separator
*On
Default All UPC E
Settings
UPC E
UPEDFT
7-21
Off
UPEEN00
UPEEN01
UPEEN10
UPEEN11
UPEEXP0
UPEEXP1
UPECKX0
UPECKX1
UPENSX0
UPENSX1
UPEAD20
UPEAD21
UPEAD50
UPEAD51
UPEARQ0
UPEARQ1
UPEADS0
UPEADS1
7-21
7-21
7-21
7-21
7-22
7-22
7-23
7-23
7-23
7-23
7-23
7-23
7-23
7-23
7-22
7-22
7-22
7-22
UPC E0
*On
Off
UPC E1
*On
*Off
UPC E Expand
On
Off
UPC E Check Digit
UPC E Number System
UPC E 2 Digit Addenda
UPC E 5 Digit Addenda
UPC E Addenda Required
*On
Off
*On
*Off
On
*Off
On
*Not Required
Required
Off
UPC E Addenda
Separator
*On
11 - 14
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Default All EAN/
JAN 13 Settings
EAN/JAN 13
EAN/JAN 13
E13DFT
7-24
Off
E13ENA0
E13ENA1
E13CKX0
E13CKX1
E13AD20
E13AD21
E13AD50
E13AD51
E13ARQ0
E13ARQ1
E13ADS0
E13ADS1
E13ISB0
E13ISB1
7-24
7-24
7-24
7-24
7-24
7-24
7-24
7-24
7-25
7-25
7-25
7-25
7-25
7-25
*On
Off
EAN/JAN 13 Check Digit
*On
*Off
EAN/JAN 13 2 Digit
Addenda
On
*Off
EAN/JAN 13 5 Digit
Addenda
On
*Not Required
EAN/JAN 13 Addenda
Required
Required
Off
EAN/JAN 13 Addenda
Separator
*On
*Off
ISBN Translate
EAN/JAN 8
On
Default All EAN/
JAN 8 Settings
EA8DFT
7-26
Off
EA8ENA0
EA8ENA1
EA8CKX0
EA8CKX1
EA8AD20
EA8AD21
EA8AD50
EA8AD51
EA8ARQ0
EA8ARQ1
EA8ADS0
EA8ADS1
CPNENA0
CPNENA1
MSIDFT
7-26
7-26
7-26
7-26
7-26
7-26
7-26
7-26
7-27
7-27
7-27
7-27
7-27
7-21
7-27
EAN/JAN 8
*On
Off
EAN/JAN 8 Check Digit
*On
*Off
EAN/JAN 8 2 Digit
Addenda
On
*Off
EAN/JAN 8 5 Digit
Addenda
On
*Not Required
EAN/JAN 8 Addenda
Required
Required
Off
EAN/JAN 8 Addenda
Separator
Off
Coupon Code
MSI
*On
Default All MSI Settings
IT5600/IT5800 User’s Guide
11 - 15
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
*Off
On
MSIENA0
MSIENA1
7-27
7-27
MSI
*Validate Type 10, but Don’t
Transmit
MSICHK0
MSICHK1
7-28
7-28
MSI Check Character
Validate Type 10 and
Transmit
Minimum (4 - 48) *4
Maximum (4 - 48) *48
Default All Plessey Settings
*Off
MSIMIN##
MSIMAX##
PLSDFT
7-28
7-28
7-29
7-29
7-29
7-29
7-29
MSI Message Length
Plessey Code
PLSENA0
PLSENA1
PLSMIN##
PLSMAX##
Plessey Code
On
Minimum (4 - 48) *4
Maximum (4 - 48) *48
Plessey Message Length
RSS-14
Default All
RSS-14 Settings
RSSDFT
7-30
Off
RSSENA0
RSSENA1
7-30
7-30
RSS-14
*On
Default All RSS-14
Limited Settings
RSS Limited
RSLDFT
7-30
Off
RSLENA0
RSLENA1
7-30
7-30
RSS Limited
*On
Default All RSS-14
Expanded Settings
RSS Expanded
RSS Expanded
RSEDFT
7-31
Off
RSEENA0
RSEENA1
RSEMIN##
RSEMAX##
EANEMU2
EANEMU1
EANEMU0
7-31
7-31
7-31
7-31
7-31
7-31
7-31
*On
Minimum (4 - 74) *4
Maximum (4 - 74) *74
RSS Emulation
128 Emulation
*EAN•UCC Emulation Off
RSS Expanded Msg.
Length
EAN•UCC Emulation
Default All China Post Code
Settings
China Post Code
China Post Code
CPCDFT
7-32
*Off
On
CPCENA0
CPCENA1
7-32
7-32
11 - 16
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Serial
Setting
* Indicates default
Command
# Indicates a
numeric entry
Selection
Page
Minimum (2 - 80) *4
Maximum (2 - 80) *80
CPCMIN##
CPCMAX##
7-32
7-32
China Post Code Msg.
Length
Default All Korea Post Code
Settings
Korea Post Code
Korea Post Code
KPCDFT
7-33
*Off
KPCENA0
KPCENA1
KPCMIN##
KPCMAX##
POSDFT
7-33
7-33
7-33
7-33
7-34
7-34
7-34
7-34
7-34
7-34
7-34
7-34
7-35
7-35
On
Minimum (2 - 80) *4
Maximum (2 - 80) *48
Default All PosiCode Settings
Off
Korea Post Code Msg.
Length
PosiCode
POSENA0
POSENA1
POSLIM0
POSLIM1
POSLIM2
POSMIN##
POSMAX##
TRIENA0
*On
PosiCode
A and B On
A and B and Limited A On
*A and B and Limited B On
Minimum (2 - 80) *4
Maximum (2 - 80) *48
*Off
PosiCode Msg. Length
Trioptic Code
Codablock F
Codablock F
On
TRIENA1
Default All Codablock F Set-
tings
CBFDFT
7-35
*Off
CBFENA0
CBFENA1
CBFMIN####
CBFMAX####
16KDFT
7-35
7-35
7-35
7-35
7-36
7-36
7-36
7-36
7-36
7-36
7-37
7-37
7-37
7-37
On
Minimum (1 - 2048) *1
Maximum (1 - 2048) *2048
Default All Code 16K Settings
*Off
Codablock F Msg. Length
Code 16K
16KENA0
Code 16K
On
16KENA1
Minimum (0 - 160) *1
Maximum (0 - 160) *160
Off
16KMIN###
16KMAX###
Code 16K
Code 49
Code 49
C49ENA0
C49ENA1
C49MIN##
C49MAX##
*On
Minimum (1 - 81) *1
Maximum (1 - 81) *81
Code 49
IT5600/IT5800 User’s Guide
11 - 17
Download from Www.Somanuals.com. All Manuals Search And Download.
11 - 18
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
12
Product Specifications
IT5600 Product Specifications
Parameter
Specification
Dimensions (Typical):
Height
6.2 inches (15.7 cm)
5.3 inches (13.5 cm)
3.2 inches (8.1 cm)
6.5 ounces (185 g)
Length
Width
Weight
Light Source
Scan Rate
630 nM visible red LED
270 scans per second in most usages
65 degrees
Skew Angle
Pitch Angle
65 degrees
Horizontal Velocity
Scan Contrast
Voltage Requirements
Current Draw (Max):
2 inches (5 cm) per second
20% minimum
4.5 to 12VDC at scanner
Scanning
235mA
142mA
235mA
127mA
210mA
120mA
Standby
68mA
48mA
68mA
48mA
60mA
49mA
Inrush
Low Power
5600SR000 Model @5Vdc
350mA
100µA
@12Vdc
5600SR010/050 Model @5Vdc
@12Vdc
-
-
350mA
100µA
-
-
5600SR030 Model @5Vdc
@12Vdc
350mA
-
100µA
-
Temperature Ranges:
Operating
32° F to +122° F (0° C to +50° C)
-40° F to +140° F (-40° C to +60° C)
0 to 95% non-condensing
Storage
Humidity
Operational after 50 drops from 6 feet
(1.8 m) to concrete
Mechanical Drop
Vibration
Withstands 5G peak from 22 to 300 Hz
15 kV to any external surface
ESD Sensitivity
Sealant Rating
FCC Class B, CE EMC Class B, CE Low
Agency Compliance
Voltage Directive, EN60825-1 LED Safety; Class 1,
UL, cUL, TÜV Certified to EN60950, C-Tick, NOM
IT5600/IT5800 User’s Guide
12 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
IT5600 Depth of Field
Minimum Bar Maximum Near Minimum Far Field
Width
Field
(no ambient lighting)
13 mil 100% UPC
1 in (2.5 cm)
24 in (61 cm)
7.5 mil Code 39
10 mil Code 39
13 mil Code 39
15 mil Code 39
20 mil Code 39
55 mil Code 39
4 in (10 cm)
2 in (5 cm)
14 in (36 cm)
18 in (46 cm)
24 in (61 cm)
28 in (71 cm)
36 in (91 cm)
44 in (112 cm)
1 in (2.5 cm)
1 in (2.5 cm)
1 in (2.5 cm)
4 in (10.2 cm)
12 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
IT5800 Product Specifications
Parameter
Specification
Dimensions (Typical):
without aimer
with aimer
Height
6.4 inches (16.3 cm)
5.3 inches (13.5 cm)
3.2 inches (8.1 cm)
7.5 ounces (213 g)
630 nm visible red LED
6.5 inches (16.5 cm)
5.3 inches (13.5 cm)
3.2 inches (8.1 cm)
8.4 oz. (238 g)
Length
Width
Weight
Light Source
Aimer Beam Light Source
Scan Rate
Class 2 Laser Product, 1.0 mW Max Output:650 nm
270 scans per second in most usages
65 degrees
Skew Angle
Pitch Angle
65 degrees
Horizontal Velocity
Scan Contrast
Voltage Requirements
Current Draw (Max):
2 inches (5 cm) per second
20% minimum
4.5 to 12VDC at scanner
Scanning
235mA
142mA
235mA
127mA
210mA
120mA
Standby
68mA
48mA
68mA
48mA
60mA
49mA
Inrush
Low Power
5800SR00X Model @5Vdc
350mA
100µA
@12Vdc
5800SR05X Model @5Vdc
@12Vdc
-
-
350mA
100µA
-
-
5800SR03X Model @5Vdc
@12Vdc
350mA
-
100µA
-
Temperature Ranges:
Operating
Storage
-22° F to +122° F (-30° C to +50° C)
-40° F to +140° F (-40° C to +60° C)
0 to 95% non-condensing
Humidity
Operational after 50 drops from 6.5 feet (2 m) to
concrete @ -22° F (-30° C)
Mechanical Drop
Vibration
Withstands 5G peak from 22 to 300 Hz
15 kV to any external surface
ESD Sensitivity
Sealant Rating
IP 54 (Water and Dust Resistant)
FCC Class B, CE EMC Class B, CE Low
Agency Compliance
Voltage Directive, EN60825-1 LED Safety; Class 1,
UL, cUL, TÜV Certified to EN60950, C-Tick, NOM
IT5600/IT5800 User’s Guide
12 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
IT5800 Depth of Field
Min. Bar
Width
Max.
Near Field
Min. Far Field
(25 Lux lighting)
Min. Far Field
(300 Lux lighting)
13 mil 100% UPC
2.5 in (6.4 cm)
26 in (66 cm)
28 in (71 cm)
7.5 mil Code 39
15 mil Code 39
20 mil Code 39
55 mil Code 39
6.5 in (16.5 cm)
2.5 in (6.4 cm)
1.5 in (3.8 cm)
4 in (10.2 cm)
14 in (36 cm)
30 in (76.2 cm)
39 in (99.1 cm)
63 in (160 cm)
15 in (38 cm)
31 in (78.7 cm)
42 in (107 cm)
82 in (208 cm)
12 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Cable Pinouts
Keyboard Wedge
otscrhandle
12 - 6
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Cable Pinouts
Wand Emulation
ostcrhandle
IT5600/IT5800 User’s Guide
12 - 7
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Cable Pinouts
Serial Output
1
otscrhandle
12 - 8
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Standard Cable Pinouts
USB
ostcrhandle
IT5600/IT5800 User’s Guide
12 - 9
Download from Www.Somanuals.com. All Manuals Search And Download.
12 - 10
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
13
Maintenance
Repairs
Repairs and/or upgrades are not to be performed on this product. These
services are to be performed only by an authorized service center. Please see
Customer Support on page 14-1 for further information.
Maintenance
The IT5600/5800 provides reliable and efficient operation with a minimum of
care. Although specific maintenance is not required, the following periodic
checks ensure dependable scanner operation:
Cleaning the Scanner’s Window
Reading performance may degrade if the scanner’s window is not clean. If the
window is visibly dirty, or if the scanner isn’t operating well, clean the window with
a soft cloth or lens tissue dampened with water (or a mild detergent- water
solution or alcohol). If a detergent solution is used, rinse with a clean lens tissue
dampened with water only.
The scanner’s housing may also be cleaned the same way.
Caution:
!
Do not submerge the imager in water. Do not use
abrasive wipes or tissues on the imager’s window –
abrasive wipes may scratch the window.
Never use solvents (e.g., acetone, benzene, ether, or
phenol-based agents) on the housing or window –
solvents may damage the finish or the window.
Inspecting Cords and Connectors
Inspect the scanner’s interface cable and connector for wear or other signs of
operation. Contact your Hand Held Products distributor for information about
cable replacement. Cable replacement instructions are on page 13-2.
IT5600/IT5800 User’s Guide
13 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Replacing the Interface Cable
The standard interface cable is attached to the scanner with an 10-pin modular
connector. When properly seated, the connector is held in the IT5600/5800
scanner’s handle by a flexible retention tab. The interface cable is designed to
be field replaceable.
•
Order replacement cables from Hand Held Products or from an authorized
distributor.
•
When ordering a replacement cable, specify the cable part number of the
original interface cable.
To Replace the IT5600 Interface Cable:
1. Turn the power to the host system
OFF.
2. Disconnect the scanner’s cable from
the terminal or computer.
3. Locate the small hole on the side of
the scanner’s handle (IT5600/5800).
This is the cable release.
4. Straighten one end of a paper clip.
5. Insert the end of the paper clip into the
small hole and press in. This
depresses the retention tab, releasing
the connector. Pull the connector out
while maintaining pressure on the
paper clip, then remove the paper clip.
Cable
Release
6. Replace with the new cable.
Insert the connector into the opening
and press firmly. The connector is
keyed to go in only one way, and will click into place.
13 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
To Replace the IT5800 Interface Cable:
1. Turn the power to the host system
OFF.
2. Disconnect the imager’s cable from
the terminal or computer.
3. Use a screwdriver to unscrew the cord
lock from the base of the imager if in
use.
4. Locate the small hole on the side of
the imager’s handle. This is the cable
release.
Cable
Release
5. Straighten one end of a paper clip.
6. Insert the end of the paper clip into the
small hole and press in. This
depresses the retention tab, releasing
the connector. Pull the connector out
while maintaining pressure on the
paper clip, then remove the paper clip.
Cord lock
7. Replace with the new cable.
Insert the connector into the opening
and press firmly. The connector is keyed to go in only one way, and will click
into place.
8. If the cord lock is used, screw it back in place over the cord.
Troubleshooting
The scanner automatically performs self-tests whenever you turn it on. If your
scanner is not functioning properly, review the following Troubleshooting Guide
to try to isolate the problem.
Is the power on? Is the red aiming illumination line on?
If the red aiming illumination line isn’t illuminated, check that:
•
•
•
The cable is connected properly.
The host system power is on (if external power isn’t used).
The trigger works.
Is the scanner having trouble reading your symbols?
If the scanner isn’t reading symbols well, check that the symbols:
•
•
Aren’t smeared, rough, scratched, or exhibiting voids.
Aren’t coated with frost or water droplets on the surface.
IT5600/IT5800 User’s Guide
13 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
•
Are enabled in the scanner or in the decoder to which the scanner connects.
Is the bar code displayed but not entered?
The bar code is displayed on the host device correctly, but you still have to press
a key to enter it (the Enter/Return key or the Tab key, for example).
You need to program a suffix. Programming a suffix enables the scanner to
output the bar code data plus the key you need (such as “CR”) to enter the data
into your application. Refer to Prefix/Suffix Overview on page 4-1 for further
information.
Does the scanner read the bar code incorrectly?
If the scanner reads a bar code, but the data is not displayed correctly on the host
screen:
•
The scanner may not be programmed for the appropriate terminal interface.
For example, you scan “12345” and the host displays “@es%.”
Reprogram the scanner with the correct Plug and Play or Terminal selection
bar code. See Chapter 1 and Chapter 2.
•
The scanner may not be programmed to output your bar code data properly.
For example, you scan “12345” and the host displays “A12345B.”
7.
The scanner won’t read your bar code at all.
1. Scan the sample bar codes in the back of this manual. If the scanner reads
the sample bar codes, check that your bar code is readable.
Verify that your bar code symbology is enabled (see Chapter 7).
2. If the scanner still can’t read the sample bar codes, scan All Symbologies on
page 7-1.
If you aren’t sure what programming options have been set in the scanner, or if
you want the factory default settings restored, scan Resetting the Standard
Product Defaults on page 11-4.
13 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
14
Customer Support
Product Service and Repair
Hand Held Products provides service for all its products through service centers
throughout the world. To obtain warranty or non-warranty service, return the unit
to Hand Held Products (postage paid) with a copy of the dated purchase record
attached. Contact the appropriate location below to obtain a Return Material
Authorization number (RMA #) before returning the product.
North America
Hand Held Products Corporate Offices
Telephone: (800) 782-4263, Option 3
Fax: (704) 566-6015
E-mail: [email protected]
America Latina
Hand Held Products America Latina
Teléfono: (239) 263-7600
Fax: (239) 263-9689
E-mail: [email protected]
Brazil
Hand Held Products Brazil
Telephone: +55 (21) 2176-0250
Fax: +55 (21) 2176-0249
E-mail: [email protected]
Europe, Middle East, and Africa
Hand Held Products Europe
Telephone:+ 31 (0) 40 29 01 633
Fax: + 31 (0) 40 2901631
E-mail: [email protected]
Asia Pacific
Hand Held Products Asia/Pacific
Telephone: +852-2511-3050
Fax: +852-2511-3557
E-mail: [email protected]
Japan
Hand Held Products Japan
Telephone: +81-3-5770-6312
Fax: +81-3-5770-6313
E-mail: [email protected]
IT5600/IT5800 User’s Guide
14 - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
Online Product Service and Repair Assistance
You can also access product service and repair assistance online at
Technical Assistance
If you need assistance installing or troubleshooting your scanner, please call
your Distributor or the nearest Hand Held Products technical support office:
North America/Canada:
Telephone:
Fax number:
E-mail:
(800) 782-4263, option 4 (8 a.m. to 6 p.m. EST)
(315) 685-4960
Europe, Middle East, and Africa:
Telephone-
European Ofc: Int+31 (0) 40 29 01 600
U.K. Ofc:
E-mail:
Int+44 1925 240055
Asia Pacific:
Telephone:
E-mail:
Int+852-3188-3485 or 2511-3050
America Latina:
Teléfono:
E-mail:
(704) 998-3998, opción 8
Online Technical Assistance
Limited Warranty
Hand Held Products, Inc. ("Hand Held Products") warrants its products to be free
from defects in materials and workmanship and to conform to Hand Held
Products’ published specifications applicable to the products purchased at the
time of shipment. This warranty does not cover any Hand Held Products product
which is (i) improperly installed or used; (ii) damaged by accident or negligence,
including failure to follow the proper maintenance, service, and cleaning
schedule; or (iii) damaged as a result of (A) modification or alteration by the
purchaser or other party, (B) excessive voltage or current supplied to or drawn
from the interface connections, (C) static electricity or electro-static discharge,
(D) operation under conditions beyond the specified operating parameters, or (E)
repair or service of the product by anyone other than Hand Held Products or its
authorized representatives.
14 - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
This warranty shall extend from the time of shipment for the duration published
by Hand Held Products for the product at the time of purchase ("Warranty
Period"). Any defective product must be returned (at purchaser’s expense)
during the Warranty Period to Hand Held Products’ factory or authorized service
center for inspection. No product will be accepted by Hand Held Products
without a Return Materials Authorization, which may be obtained by contacting
Hand Held Products. In the event that the product is returned to Hand Held
Products or its authorized service center within the Warranty Period and Hand
Held Products determines to its satisfaction that the product is defective due to
defects in materials or workmanship, Hand Held Products, at its sole option, will
either repair or replace the product without charge, except for return shipping to
Hand Held Products.
EXCEPT AS MAY BE OTHERWISE PROVIDED BY APPLICABLE LAW, THE
FOREGOING WARRANTY IS IN LIEU OF ALL OTHER COVENANTS OR
WARRANTIES, EITHER EXPRESSED OR IMPLIED, ORAL OR WRITTEN,
INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTIES OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE.
Hand Held Products’ RESPONSIBILITY AND PURCHASER’S EXCLUSIVE
REMEDY UNDER THIS WARRANTY IS LIMITED TO THE REPAIR OR
REPLACEMENT OF THE DEFECTIVE PRODUCT. IN NO EVENT SHALL
Hand Held Products BE LIABLE FOR INDIRECT, INCIDENTAL, OR
CONSEQUENTIAL DAMAGES, AND, IN NO EVENT, SHALL ANY LIABILITY
OF Hand Held Products ARISING IN CONNECTION WITH ANY PRODUCT
SOLD HEREUNDER (WHETHER SUCH LIABILITY ARISES FROM A CLAIM
BASED ON CONTRACT, WARRANTY, TORT, OR OTHERWISE) EXCEED
THE ACTUAL AMOUNT PAID TO Hand Held Products FOR THE PRODUCT.
THESE LIMITATIONS ON LIABILITY SHALL REMAIN IN FULL FORCE AND
EFFECT EVEN WHEN Hand Held Products MAY HAVE BEEN ADVISED OF
THE POSSIBILITY OF SUCH INJURIES, LOSSES, OR DAMAGES. SOME
STATES, PROVINCES, OR COUNTRIES DO NOT ALLOW THE EXCLUSION
OR LIMITATIONS OF INCIDENTAL OR CONSEQUENTIAL DAMAGES, SO
THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU.
All provisions of this Limited Warranty are separate and severable, which means
that if any provision is held invalid and unenforceable, such determination shall
not affect the validity of enforceability of the other provisions hereof. Use of any
peripherals not manufactured/sold by Hand Held Products voids the warranty.
This includes but is not limited to: cables, power supplies, cradles, and docking
stations. Hand Held Products, Inc. extends these warranties only to the first end-
users of the products. These warranties are nontransferable.
The limited duration of the warranty for the IT5600 is for five (5) years.
The limited duration of the warranty for the IT5800 is for three (3) years.
IT5600/IT5800 User’s Guide
14 - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
14 - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Appendix A
Symbology Chart
Code AIM Hex
Code AIM Hex
Symbology
Symbology
ID
ID
ID
ID
ID
ID
Q
]X0
51
61
71
66
68
6F
62
3C
f
66
China Post
Codabar
IATA 2 of 5
Interleaved 2 of 5
Korea Post
Matrix 2 of 5
MSI
]Rm
]lm
a
q
f
e
65
3F
6D
67
9C
6E
57
]Fm
]Om
]Rm
]Hm
]Km
]Am
]X0
?
]X0
]X0
Codablock F
Code 2 of 5
Code 11
m
g
h
o
b
<
]Mm
Code 16K
Code 39
No Read
n
]P0
Plessey Code
Code 32 Pharma-
ceutical (PARAF)
W
]pm
PosiCode
l
6C
Reduced Space
Symbology (RSS-
14, RSS Limited,
RSS Expanded)
y
79
]Tm
]em
Code 49
i
69
6A
49
44
t
74
3D
63
63
Code 93
Telepen
]Gm
]Cm
]C1
]Bm
]X0
j
=
c
c
Code 128
Trioptic Code
UPC-A
I
UCC/EAN-128
]E0
]E3
D
]E4
UPC-A with
Extended Coupon
Code
EAN/JAN-8
d
d
64
64
E
45
99
EAN/JAN-13
UPC-E
]E0
]E3
]E0
EAN-13 with
Extended
Coupon Code
Note: “m” represents the AIM modifier character. Refer to International
Technical Specification, Symbology Identifiers, for AIM modifier character
details.
Note: Prefix/Suffix entries for specific symbologies override the universal (All
Refer to Data Editing beginning on page 4-1 and Data Formatting beginning on
page 5-1 for information about using Code ID and AIM ID.
IT5600/IT5800 User’s Guide
A - 1
Download from Www.Somanuals.com. All Manuals Search And Download.
ASCII Conversion Chart (Code Page 1252)
Note:
This table applies to U.S. style keyboards. Certain characters may differ depending on your
Country Code/PC regional settings.
Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char
0
00
01
02
03
04
05
06
07
08
09
0A
0B
0C
0D
0E
0F
10
11
NUL
SOH
STX
ETX
EOT
ENQ
ACK
BEL
BS
32
33
34
35
36
37
38
39
40
41
42
43
44
45
46
47
48
49
50
51
52
53
54
55
56
57
58
59
60
61
62
63
20
21
22
23
24
25
26
27
28
29
2A
2B
2C
2D
2E
2F
30
31
32
33
34
35
36
37
38
39
3A
3B
3C
3D
3E
3F
64
65
66
67
68
69
70
71
72
73
74
75
76
77
78
79
80
81
82
83
84
85
86
87
88
89
90
91
92
93
94
95
40
41
42
43
44
45
46
47
48
49
4A
4B
4C
4D
4E
4F
50
51
52
53
54
55
56
57
58
59
5A
5B
5C
5D
5E
5F
@
A
B
C
D
E
F
G
H
l
96
97
98
99
60
61
62
63
‘
1
!
a
b
c
d
e
f
2
“
3
#
$
%
&
‘
4
100 64
101 65
102 66
103 67
104 68
105 69
106 6A
107 6B
108 6C
109 6D
110 6E
5
6
7
g
h
i
8
(
9
HT
)
10
11
12
13
14
15
16
17
18
19
20
21
22
23
24
25
26
27
28
29
30
31
LF
*
J
j
VT
+
,
K
L
k
l
FF
CR
-
M
N
O
P
Q
R
S
T
U
V
W
X
Y
Z
[
m
n
o
p
q
r
SO
.
SI
/
111
6F
DLE
DC1
DC2
DC3
DC4
NAK
SYN
ETB
CAN
EM
0
1
2
3
4
5
6
7
8
9
:
112 70
113 71
114 72
115 73
116 74
117 75
118 76
119 77
120 78
121 79
122 7A
123 7B
124 7C
125 7D
126 7E
127 7F
12
13
14
15
16
17
18
19
1A
1B
1C
1D
1E
1F
s
t
u
v
w
x
y
z
{
SUB
ESC
FS
;
<
=
>
?
\
|
GS
]
}
RS
^
~
US
_
A - 2
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Dec Hex Char Dec Hex Char Dec Hex Char Dec Hex Char
128
129
130
131
132
133
134
135
136
137
138
80
81
82
83
84
85
86
87
88
89
8A
€€
160 A0
161 A1
162 A2
163 A3
164 A4
165 A5
166 A6
167 A7
168 A8
169 A9
170 AA
192 C0
193 C1
194 C2
195 C3
196 C4
197 C5
198 C6
199 C7
200 C8
201 C9
202 CA
À
Á
Â
Ã
Ä
Å
Æ
Ç
È
É
Ê
224
225
226
227
228
229
230
231
232
233
234
E0
E1
E2
E3
E4
E5
E6
E7
E8
E9
EA
à
á
â
ã
ä
å
æ
ç
¡
‚
¢
£
¤
¥
¦
ƒ
„
…
†
‡
ˆ
§
¨
è
é
ê
‰
Š
©
ª
«
¬
-
139
140
141
142
143
144
145
146
147
148
149
150
151
152
153
154
8B
8C
8D
8E
8F
90
91
92
93
94
95
96
97
98
99
9A
‹
171 AB
172 AC
173 AD
174 AE
175 AF
176 B0
177 B1
178 B2
179 B3
180 B4
181 B5
182 B6
183 B7
184 B8
185 B9
186 BA
203 CB
204 CC
205 CD
206 CE
207 CF
208 D0
209 D1
210 D2
211 D3
212 D4
213 D5
214 D6
215 D7
216 D8
217 D9
218 DA
Ë
Ì
235
236
237
238
239
240
241
242
243
244
245
246
247
248
249
250
EB
EC
ED
EE
EF
F0
F1
F2
F3
F4
F5
F6
F7
F8
F9
FA
ë
ì
Œ
Í
í
Ž
®
¯
°
Î
î
Ï
ï
Ð
Ñ
Ò
Ó
Ô
Õ
Ö
×
Ø
Ù
Ú
ð
ñ
ò
ó
ô
õ
ö
÷
ø
ù
ú
‘
±
²
’
“
³
”
´
•
µ
¶
·
–
—
˜
¸
™
š
¹
155
156
157
158
159
9B
9C
9D
9E
9F
›
187 BB
188 BC
189 BD
190 BE
191 BF
»
219 DB
220 DC
221 DD
223 DF
Û
Ü
Ý
ß
251
252
253
254
255
FB
FC
FD
FE
FF
û
ü
ý
þ
ÿ
œ
¼
½
¿
ž
Ÿ
IT5600/IT5800 User’s Guide
A - 3
Download from Www.Somanuals.com. All Manuals Search And Download.
Code Page Mapping of Printed Bar Codes
Code pages define the mapping of character codes to characters. If the data
received does not display with the proper characters, it may be because the bar
code being scanned was created using a code page that is different from the one
the host program is expecting. If this is the case, select the code page with which
the bar codes were created. The data characters should then appear properly.
Note: The Code Page option is available for Code 39, Code 93, and Code 128.
Code Page
1
Standard
CP ISO646
ISO 2022
Description
2 (Default)
Automatic National Replacement
Characters
3
CP Binary
82
83
ISO 2022 11 Swe
ISO 2022 69 Fra
Swedish Replacement Characters
French/Belgium Replacement Charac-
ters
81
ISO 2022 25 Fra
French/Belgium Replacement Charac-
ters
84
85
86
87
88
89
90
ISO 2022 11 Ger
ISO 2022 11 Ita
ISO 2022 11 Swi
ISO 2022 11 UK
ISO 2022 11 Dan
ISO 2022 11 Nor
ISO 2022 11 Spa
German Replacement Characters
Italian Replacement Characters
Swiss Replacement Characters
British Replacement Characters
Danish Replacement Characters
Norwegian Replacement Characters
Spanish Replacement Characters
A - 4
IT5600/IT5800 User’s Guide
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
Sample Symbols
Code 39
Codabar
BC321
Code 93
A13579B
Code 2 of 5
123456-9$
Matrix 2 of 5
123456
6543210
RSS-14
(01)00123456789012
Download from Www.Somanuals.com. All Manuals Search And Download.
Hand Held Products, Inc.
700 Visions Drive
P.O. Box 208
Skaneateles Falls, NY 13153-0208
56-5800-UG Rev C