Halsey Taylor Indoor Furnishings HRFG ERA User Manual

HRFG - ER*A HRFG - SR*A HRFG - SER*A  
Halsey Taylor Owners Manual  
Refrigerated Marblyte Fountains with Back Panel  
Installer  
To assure you install this model easily and correctly, PLEASE  
READ THESE SIMPLE INSTRUCTIONS BEFORE STARTING  
THE INSTALLATION. CHECK YOUR INSTALLATION FOR  
COMPLIANCE WITH PLUMBING, ELECTRICAL AND OTHER  
APPLICABLE CODES. After installation, leave these instruc-  
tions inside the fountain for future reference.  
IMPORTANT  
ALL SERVICE TO BE PERFORMED BY AN AUTHORIZED SERVICE PERSON  
IMPORTANT! INSTALLER PLEASE NOTE.  
THE GROUNDING OF ELECTRICAL EQUIPMENT SUCH AS TELEPHONE, COMPUTERS, ETC. TO  
WATER LINES ISACOMMON PROCEDURE. THIS GROUNDING MAY BE IN THE BUILDING OR MAY  
OCCURAWAY FROM THE BUILDING. THIS GROUNDING CAN CAUSE ELECTRICALFEEDBACK  
INTOAFOUNTAIN, CREATINGAN ELECTROLYSIS WHICH CAUSESAMETALLIC TASTE ORAN  
INCREASE IN THE METAL CONTENT OF THE WATER. THIS CONDITION ISAVOIDABLE BY USING  
THE PROPER MATERIALSAS INDICATED.ANY DRAIN FITTINGS PROVIDED BYTHE INSTALLER  
SHOULD BE MADE OF PLASTIC TO ELECTRICALLY ISOLATE THE FOUNTAIN FROM THE BUILDING  
PLUMBING SYSTEM.  
97716C (Rev. A - 5/02)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HRFG - ER*A HRFG - SR*A HRFG - SER*A  
HRFG-SER ROUGH-IN  
LEGEND:  
A = 3/8" O.D. TUBE WATER OUTLET  
B = 3/8" O.D. TUBE WATER INLET  
C = 1-1/4" O.D. WASTE TUBE (NOT INCLUDED)  
FIG. 2  
97716C (Rev. A - 5/02)  
PAGE 3  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HRFG - ER*A HRFG - SR*A HRFG - SER*A  
INSTALLATION INSTRUCTIONS  
1. Install remote chiller. Remove front panel of chiller. Remove and discard cardboard inner pack from be  
tween compressor and side panel. Slide chiller onto the shelf and position it to the left within the guides  
on the shelf.  
NOTE: Building construction must allow for adequate air flow on both sides, top, and back of chiller. A  
minimum of 4" (102mm) on both sides and top is required. See chiller instructions for additional instructions.  
2. Make water supply connections. Attach an unplated copper water inlet line and a service stop (not  
provided) to the chiller. Inlet port is marked on the chiller (3/8" O.D. copper tube). Bend the copper tube  
(provided) at an appropriate length from chiller to opening in frame. Install a 3/8" O.D. tube tee fitting (pro  
vided) on the marked chiller outlet port. Turn on the water supply and flush the line thoroughly.  
3. Hang the upper panel on the mounting frame hanger. Align holes in the panel with the holes in the  
mounting frame. Be sure that panel is engaged with hanger at top of frame before releasing it.  
4. Install fountain. Remove access cover plate on underside of fountains and save the screws. Mount the  
fountains to the upper panel and the wall frame with (4) 5/16" x 1-1/4" (32mm) long bolts, washers, and nuts.  
Tighten securely, but do not overtighten. Over tightening will crack the Marblyte Fountain.  
NOTE: The short fountain should be mounted to the upper left hand side of the panel.  
5. Remove elbow from end of p-trap and attach it to drain tube. Re-attach elbow to p-trap and cut waste  
tube to required length using plumbing hardware and trap as a guide.  
6. Make connection between remote chiller outlet tube and fountain strainer. Insert the water inlet line  
into inlet side of strainer by pushing it in until it reaches a positive stop, approximately 3/4" (19mm). Turn on  
water supply and check for leaks. Newly installed water supply line should be insulated after leak check is  
completed. DO NOT SOLDER TUBES INSERTED INTO THE STRAINER AS DAMAGE TO THE O-RINGS  
MAY RESULT.  
7. These products are designed to operate on 20-105 PSIG supply line pressure. If inlet pressure is above  
105 PSIG, a pressure regulator must be installed in the supply line. Any damage caused by reason of  
connecting these products to supply line pressures lower than 20 PSIG or higher than 105 PSIG is not  
covered by warranty.  
8. Make electrical connections to the chiller. See chiller instructions.  
9. Check stream height from bubbler. Stream height is factory set at 45-50 PSI. If supply pressure varies  
greatly from this, remove items 5 & 13 (See Figure 6, Page 6) by loosening set screw (item 10) and adjust  
the screw on regulator (item 9). Clockwise adjustment will raise stream height and counter-clockwise  
adjustment will lower stream height. For best adjustment stream height should be approximately 1-1/2"  
(38mm) above the bubbler guard (See Figure 5, Page 5).  
10. Mount lower panel. Loosen the (2) #10-24 x 5/8" (16mm) screws at frame bottom lip. Slide upper tongue  
of lower panel under lower edge of already installed upper panel. Tighten previously loosened screws  
securely.  
11. Replace bottom access panel to fountain basin using screws provided. Tighten securely.  
Care and Maintenance of Halsey Taylor Marblyte Fountains  
Marblyte provides an exremely durable, nonporous surface which resists staining. Care is very  
simple. Routine cleaning with a soft sponge or cloth, or with water or non-abrasive aerosol foam  
cleaner, is all that is normally needed to give many years of trouble free service. Cleaners left  
standing on the fountain surface can dull the surface finish. Be certain to rinse all cleaning agents  
completely and polish with a soft cloth.  
Harsh abrasive cleaners are not required and should not be used.  
Mild abrasives such as liquid automotive cleaning compound or baking soda paste will remove  
simple scratches and stains. Cigarette burns can normally be removed without noticeable effect.  
Deeper scratches or gouges can be corrected with fine grit sandpaper (240 grit then 400 grit) or a  
green Scotchbrite pad.  
To maintain or regain luster and make cleaning easier, periodic applications of automobile wax or  
like products will keep the finish looking like new.  
97716C (Rev. A - 5/02)  
PAGE 4  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HRFG - ER*A HRFG - SR*A HRFG - SER*A  
3/8" O.D. UNPLATED  
COPPER TUBE CONNECT  
COLD WATER SUPPLY  
1/4" O.D. TUBE  
WATER INLET  
TO COOLER  
BUILDING WATER INLET  
NOTE: WATER FLOW  
DIRECTION  
SERVICE STOP  
(NOT FURNISHED)  
FIG. 3  
OPERATION OF QUICK CONNECT FITTINGS  
TUBE IS SECURED  
IN POSITION  
PUSH IN COLLET  
TO RELEASE TUBE  
SIMPLY PUSH IN  
TUBE TOATTACH  
PUSHING TUBE IN BEFORE  
PULLING IT OUT HELPS TO  
RELEASE TUBE  
FIG. 4  
FIG. 5  
PAGE 5  
97716C (Rev. A - 5/02)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HRFG - ER*A HRFG - SR*A HRFG - SER*A  
9
7
2
6
13  
5
10  
BASIN  
26  
16  
FIG. 6  
TOP VIEW  
23  
8
SEE FI
24  
25  
SEE FIG. 6  
19  
FIG. 7  
97716C (Rev. A - 5/02)  
PAGE 6  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HRFG - ER*A HRFG - SR*A HRFG - SER*A  
FIG. 8  
FIG. 9  
PAGE 7  
97716C (Rev. A - 5/02)  
Download from Www.Somanuals.com. All Manuals Search And Download.  
HRFG - ER*A HRFG - SR*A HRFG - SER*A  
PARTS LIST  
ITEMNO.  
PARTNO.  
DESCRIPTION  
1
2
3
4
5
6
7
8
9
10  
11  
12  
13  
14  
Drain  
Retaining Nut  
Strainer  
Tailpipe Ferrule  
Push Button  
Push Button Sleeve  
Regulator Holder  
Bubbler  
Regulator  
Setscrew #6-32 x .31"  
Scr, #10-24 x 1/2 PH TR HD-Z  
Strainer  
Push Button - Extension  
Bottom Cover Plate-Short  
Bottom Cover Plate-Extended  
Back Panel HRF-SER  
Back Panel HRF-ER  
Back Panel HRF-SR  
Hex Nut  
Insert - Threaded  
Bubbler Locknut  
Lower Panel HRF-SER  
Lower Panel HRF-ER  
Union - 3/8" x 1/4"  
Union - 3/8"  
LK464  
15005C  
40038C  
40619C  
45662C  
45738C  
50986C  
51544C  
61313C  
70022C  
112627543890  
55996C  
56087C  
27201C  
27658C  
26839C  
26837C  
26835C  
40045C  
75554C  
70012C  
27026C  
26833C  
70745C  
70870C  
70852C  
55969C  
56053C  
56025C  
56056C  
100322740560  
66399C  
45736C  
15  
16  
17  
18  
19  
20  
21  
22  
23  
Tee - 3/8"  
Fountain-Galaxy Gray(HRFG-S)  
Fountain-Galaxy Gray(HRFG-E)  
Fountain-Black(HRFG-S)  
Fountain-Black(HRFG-E)  
Gasket - Black  
24  
25  
26  
Tube Assy - Reg. to Bubbler  
Nut - Regulator Mounting  
TROUBLE SHOOTING & MAINTENANCE  
Orifice Assy: Mineral deposits on orifice can cause water flow to spurt or not regulate. Mineral deposits may be  
removed from the orifice with a small round file not over 1/8" diameter or small diameter wire.  
CAUTION: DO NOT file or cut orifice material.  
Stream Regulator: If orifice is free of material deposits, regulate flow as instructions on page 4(Step 9). If replace-  
ment is necessary, see parts list for correct regulator part number.  
Actuation of Quick Connect Water Fittings: Cooler is provided with lead-free connectors which utilize an o-ring  
water seal. To remove tubing from the fitting, relieve water pressure, push in on the gray collar while pulling on the  
tubing.(see Fig.4, Page 5) To insert tubing, push tube straight into fitting until it reaches a positive stop,  
approximately 3/4".  
2222 CAMDEN COURT  
OAK BROOK, IL 60523  
630.574.3500  
PRINTED IN U.S.A.  
FOR PARTS, CONTACT YOUR LOCAL DISTRIBUTOR OR CALL 1.800.323.0620  
97716C (Rev. A - 5/02)  
PAGE 8  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Greenway Home Products Indoor Fireplace MEF2808CHG User Manual
Greenway Home Products Water Dispenser GWD5960W User Manual
Grizzly Drill G0514XF User Manual
Grizzly Impact Driver G5346 User Manual
Honeywell Stud Sensor C7089 User Manual
HP Hewlett Packard Laptop Docking Station XB4000 User Manual
HP Hewlett Packard Plumbing Product 4445 95 User Manual
Husqvarna Chainsaw 61 268 272XP User Manual
Husqvarna Trimmer 326RJ User Manual
IBM Computer Drive 22P6959 User Manual