AC1011S004V0
DE45EM
DE65EM
2013
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
M
Download from Www.Somanuals.com. All Manuals Search And Download.
DE45EM/DE65EM
DE45EM
DE65EM
1.85
1.85
180/150
220/200
57/56
15
57/56
11
R410A/7.4Oz
R410A/8.1Oz
4.2
6.2
480
690
23 1/2
15
21
Unit Dimensions
13 3/8
10 5/8
12
22 1/2
14 3/4
12
25 3/16
16 1/2
14
16.8
17.7
18.6
18.6
910
740
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
3
Download from Www.Somanuals.com. All Manuals Search And Download.
E45 M E6
M
NO other extension cord is permittedꢀ
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
1.Remove the plastic cap at the
rear of the unit.(Keep the rubber
insert well for use later.)(Fig.#1)
2.Tightly screw the purchased
garden hose to the direct drain
opening.(Fig.#2)
3.Position the dehumidifier as close
as you can to the floor drain.
4.Position the opening end of the
drain hose directly over the floor
drain and start the unit.
5.When the direct drain feature is
not being used,remove the drain
hose from the direct drain opening
and plug it with the rubber cap
provided.
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
ꢆ
CURRENT
HUMIDITY
ꢇꢈ
SET
HUMIDITY
Hr
ꢅ ꢄ ꢃ
ꢁ
ꢀ
ꢂ
ꢁ
Signal
The bucket full audible signal can be turned on
and off by pressing the SIGNAL button. The
default setting is set in the ON position. When
the bucket is full, the red BUCKET FULL indicator
light will blink and the alarm will sound 5 times
every 15 minutes.
To turn off the audible signal feature, press the
SIGNAL button once, and the LED display will
show “OF” for 2 seconds. In this setting, when
the bucket is full, the BUCKET FULL indicator light
will blink, but the audible alarm will not sound.
To reactivate the audible signal, press the
SIGNAL button and the LED display to the left
will show “ON” for 2 seconds.
Power
Check Filter Indicator
The "check filter" indicator will flash when the
filter needs to be cleaned. Remove the filter,
wash it, and put it back in. Press "Filter Reset."
The "check filter" indicator will turn off.
Note: Make sure the filter is dry before replacing.
2
Bucket Full Indicator
ꢀ
When the indicator light comes on, automatic flow
control stops the unit.
Turn the unit off by pressing the POWER key.
Check to see if the bucket is full. If so, empty it.
If bucket is not full and indicator light is on, the
bucket is not in the proper position. Remove and
reinstall it.
Current Temp/Timer Set Display
5
9
When the dehumidifier is runningꢁit displays the
current temperature.Press the timer key to program
the dehumidifier to turn on or off automatically at a
pre-deter mined time.
Smart Dry
6
This setting compares the set humidity level with
the actual humidity level and adjusts the fan
speed automatically.
Current Humidity/Setting Humidity Display
Displays the current humidity level and adjusts the
humidity to a desired level.
Setting Humidity Range: 40%RH~70%RH
Display Humidity Range: (LO)30%RH~(HI)90%RH
ꢂꢃ
Download from Www.Somanuals.com. All Manuals Search And Download.
$EQRUPLW\ꢀ'LDJQRVH
M
M
ꢉꢁ$EQRUPLW\ꢂ'LDJQRVH
ꢀꢀꢀꢀꢀꢀꢀꢀ:KHQꢀDPELHQWꢀWHPSHUDWXUHꢀVHQVRUꢀDSSHDUꢀVKRUWꢀWURXEOHꢅ(ꢆꢀIDXOWꢀFRGHꢀZLOOꢀEHꢀGLVSOD\HGꢀLQꢀWKHꢀWHPSHUDWXUHꢀ
LQGLFDWRUꢀDQGꢀWKHꢀXQLWꢀRSHUDWLQJꢀZLOOꢀVWRSHGꢀꢄ:KHQꢀWKHꢀFRLOꢀWHPSHUDWXUHꢀVHQVRUꢀDSSHDUꢀVKRUWꢀWURXEOHꢅ(ꢂꢀIDXOWꢀFRGH
ZLOOꢀEHꢀGLVSOD\HGꢀLQꢀWKHꢀWHPSHUDWXUHꢀLQGLFDWRUꢀDQGꢀWKHꢀXQLWꢀZLOOꢀVWRSHGꢀꢄ
)LUVWO\ꢀFKHFNꢀZKHWKH Uꢀ7HUPLQDOꢀ&1ꢁꢀRQꢀ
WKHꢀ LQGRRUꢀ PDLQER DUGꢀ FRQWDFWꢀ ZHOOꢀ RUꢀ
QRW"
3XOOꢀ RXWꢀ WKHꢀ WHUPLQDOV ꢀ RQꢀ WKHꢀ LQGRRUꢀ
PDLQERDUG ꢀDQGꢀUHLQVHUW ꢀWKHPꢄꢀ
12
<(6
3XOOꢀWKHꢀVHQVRUꢀRXWꢀRIꢀWKHꢀPDLQERDUGꢀ
ꢂꢃꢀ 0HDVXUHꢀ WKHꢀ YDOXHꢀ RIꢀ UHVLVWDQFHꢀ
EHWZHHQꢀLWVꢀWZRꢀMXPSHU Vꢀ
<(6
ꢁꢃꢀ 0HDVXU Hꢀ WKHꢀ WHPSHUDWXUHꢀ DWꢀ WKHꢀ
URRPꢀWHPSHUDWXUHꢀVHQVLQJ ꢀKHDGꢄꢀ
&KHFNꢀWKHꢀVSHFLILFDWL RQVꢀRIꢀWKHꢀVHQVRUꢀ
WRꢀ GHFLGHꢀ ZKHWKHUꢀ WKHꢀ VHQVRU ꢀ LVꢀ
GDPDJHGꢀRUꢀQRW"ꢀ
5HSODFH ꢀZLWKꢀQHZꢀVHQVRUꢄꢀ
12
<(6
7KHꢀ,QGRRUꢀ3&%ꢀLVꢀEURNHQꢄꢀ
5HSODFH ꢀZLWKꢀQHZꢀLQGRRUꢀ3&%ꢀ
8
ꢀ
'HKXPLGLILHU
Download from Www.Somanuals.com. All Manuals Search And Download.
$EQRUPLW\ꢀ'LDJQRVH
M
M
ꢀꢀꢀꢀ:KHQꢀWKHꢀXQLWꢀLVꢀ21ꢅWKHꢀNH\ꢀLVꢀIDLOXUHꢇRIHQꢀ21ꢀRUꢀ2))ꢃꢅWKHꢀ(ꢁꢀIDXOWꢀFRGHꢀZLOOꢀEHꢀGLVSOD\HGꢀLQꢀWKHꢀWHPSHUDWXUH
LQGLFDWRUꢀDQGꢀWKHꢀXQLWꢀZLOOꢀEHꢀVWRSHGꢀꢄ
12
&KHFNꢀZKHWKHU ꢀWKHꢀNH\VWURNHꢀFDQ¶Wꢀ
JHWꢀXSꢀZLWKꢀSUHVVXUHꢄꢀ
3&%ꢀLVꢀEURNHQꢅ ꢀUHSODFH ꢀDꢀQHZꢀ3&%ꢄ
<(6
5HSDLUꢀWKHꢀNH\VWURN HVꢀRQꢀHOHFWULFDOꢀ
ER[ꢀ WRꢀ NHHSꢀ WKHPꢀ DZD\ꢀ IURPꢀ WKHꢀ
NH\VWURNHV ꢀRQꢀ3&%ꢄꢀ
9
ꢀ
'HKXPLGLILHU
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
evaporator
condenser
dehumidify
0
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
BUZZ1
R1
ꢃꢄꢄ¡
KPMG09C1-3031
R7
ꢃ.
+5V
C6
R38
N1
CN1 6ꢃꢄ%ꢅ3+ꢆ
+5V
ꢍꢀꢎ.
E1
8050
R26
+5V C30
100uF-16V 0.1uF
ꢃꢄ.
R4
0.1uF
P1
ꢊ.
2SA1037AK
R30
P2
R31
P3
R32
P4
R33
P5
P6
R70
+5V
ꢃꢄ.
8550
ꢃꢄ.
8550
ꢃꢄ.
8550
ꢃꢄ.
8550
8550
ꢃꢄ.
R68
R5
R39
R40
R41
R42
R43
ꢃꢄ.
R29 ꢊ. C7
C5 C3 C2 C4
R64
ꢍꢀꢎ.
ꢍꢀꢎ.
ꢍꢀꢎ.
ꢍꢀꢎ.
ꢍꢀꢎ.
CN24 7-&ꢈꢅꢊ
ꢃꢄ.
ꢃꢄ.
0.1uF
0.1uF0.1uF0.1uF0.1uF
C1
*1'
,54
Humidity
Temp/Timer
1
2
SMART HI
LOW T_ON T_OFF FULL FLTER
0.1uF
26&ꢃ
CN25
2
1
7-&ꢈꢅꢊ
C19
LED1
ZN013
LED2
ZN013
LED3 LED4 LED5 LED6 LED7 LED8 LED9
1
32
31
30
29
28
27
26
25
24
23
22
21
20
19
18
17
IRQ
ADC12
PTA7
2
3
4
30pF
PTA0
VSS
•
•
•
•
•
•
•
RST
OSC1
PTA5
XT1 C21 R44
5
OSC2
PTD4/T1CH0
PTD5/T1CH1
PTD2/ADC9
PTA4
30pF ꢃ0
6
7
PTA1
+5V
R61
C17
+5V
VDD
8
0.1uF
PTA2
9
+5V
PTA3
PTD3/ADC8
PTB0/ADC0
PTB1/ADC1
3.3K
10
11
12
13
14
15
16
8
9
PTB7/ADC7
PTB6/ADC6
E
COM
7C
7
10
11
12
13
14
15
16
R15
R14
R16
R17
R20
R19
R18
10K
R53
R52
R51
R50
R49
R48
R47
ꢂꢂꢄ¡
ꢂꢂꢄ¡
ꢂꢂꢄ¡
ꢂꢂꢄ¡
ꢂꢂꢄ¡
ꢂꢂꢄ¡
ꢂꢂꢄ¡
7B
6B
5B
4B
3B
2B
1B
6
10K
PTB5/ADC5 PTD1/ADC10
6C
5
10K
PTD7/RXD
PTD6/TXD
PTB2/ADC2
PTB3/ADC3
5C
4
10K
4C
3
2
1
1K
1K
1K
PTE0/T2CH0 PTD0/ADC11
3C
PTE1/T2CH1
PTB4/ADC4
2C
1C
R46 R9
IC1
0&ꢇꢈ+&ꢉꢄꢈ-/ꢈ&63(ꢅ6',3ꢂꢊ
C8
+5V
3.3K 3.3K
IC2
0.1uF E3
TVS1
100uF-16V HTVSB7.0CA-100
+5V
CN23
7-&ꢈꢅꢊ
R63
3.3K
ꢋꢌ9
'$7$
1
2
R21
ꢃ.
C11
SW1 SIGNAL
SW2 SPEED
SW3 TIMER
SW4 UP
SW5 DOWN
SW6 FLTER RESET SW7 POWER
R58
0.001uF
TSTC-2L˄6*6*5˅ TSTC-2L˄6*6*5˅ TSTC-2L˄6*6*5˅ TSTC-2L˄6*6*5˅ TSTC-2L˄6*6*5˅ TSTC-2L˄6*6*5˅ TSTC-2L˄6*6*5˅
ꢈꢀꢊ.fꢃˁ
+5V
R65
R60
R57
R6
R56
R55
R66
R59
ꢃ.fꢃˁ
ꢃ.fꢃˁ
ꢃꢀꢌ.fꢃˁ
ꢃꢀꢌ.fꢃˁ
ꢊ.fꢃˁ
ꢂ.fꢃˁ
ꢂꢀꢉ.fꢃˁ
ꢈꢀꢊ.fꢃˁ
+5V
+5V
C18
IC5 AT24C02B-DIP8
CN20
R69 R35
R67
R71
C10
8
7
6
5
1
+5V
ꢃ.
ꢃꢄ. ꢃꢄ.
ꢃꢄ.
VCC A0
1
2
3
4
0.1uF
0.01uF
2
GND
TXD
RXD
TEST A1
3
SCL A2
4
R2
ꢃꢄꢄ¡
ꢃꢄꢄ¡
R54
R3
ꢌꢇꢄ¡
SDA VSS
5267-04A
11
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
IC4
D4
1N4007
FUSE1
T3. 15A/250VAC
+12V
MC7805(1A-5V)
+5V
C20
CX1
1
3
0.1uF-275Vac
Vin
Vout
L
C9
D2
D3
1N4007
1N4007
0.1uF
E2
N
E5
CON1
RV1
D5
1N4007
2200uF-35V
220uF-25V 0.1uF
CN11
250
TVR 14561*-560V
T1
ꢍꢈꢄPPꢅꢃꢄꢅ%ꢃꢄ%ꢅ3+
BCY-4-01BK(12V-300mA-115Vac)
+5V
GND
+5V
R22
1
2
3
4
5
6
7
8
9 10
10K
)8//
IC3
I1
ULN2003-SOP16
C24
1
2
3
4
5
6
7
8
O1
O2
O3
O4
O5
O6
O7
16
15
14
13
12
11
10
R23
1K
CN5 CN6
0.1uF
I2
I3
I4
I5
I6
I7
'ꢃꢈꢎꢏꢈ$ꢐ 'ꢃꢈꢎꢏꢈ$ꢐ
+12V
C13 C16 C15 C14
0.1uF0.1uF 0.1uF 0.1uF
9
GND COM
+12V
E9
C12
K2
100uF-25V
0.1uF
K1
K3
K4
+5V
+5V
+80,',7<
ꢈꢉꢊ1ꢅꢃ$&ꢅ&ꢏ$&ꢊꢌꢄ9ꢅꢌ$ꢐ
ꢈꢉꢃ:3ꢅꢃ$ꢅ&ꢏ$&ꢊꢌꢄ9ꢅꢊꢌ$ꢐ
R36
R37
CN2
CN4
1K
1K
CN3
1
1
2
ꢈꢉꢊ1ꢅꢃ$&ꢅ&ꢏ$&ꢊꢌꢄ9ꢅꢌ$ꢐ
ꢈꢉꢊ1ꢅꢃ$&ꢅ&ꢏ$&ꢊꢌꢄ9ꢅꢌ$ꢐ
2
E7
4.7uF-50V
uF-
+5V
R34
1K
R24
R25
E8
RC1
RC2
5.1K
5.1K
4.7uF-50V
ꢂꢄꢄ9ꢅꢃꢊꢄ¡ꢅꢃꢄꢂ
ꢂꢄꢄ9ꢅꢃꢊꢄ¡ꢅꢃꢄꢂ
CN10
D187(8A)
CN8
CN7
CN9
'ꢃꢈꢎꢏꢈ$ꢐ
'ꢃꢈꢎꢏꢈ$ꢐ
D250(10A)
9$/9(
+,
/2:
&203
1
12
Download from Www.Somanuals.com. All Manuals Search And Download.
M
M
ꢄꢄꢃꢄꢌꢃꢊꢌꢈꢄ
:,5,1*ꢆ',$*5$0
%ꢑꢆ%/$&.
%/ꢑꢆ%/8(
%5ꢑꢆ%52:1
<ꢑꢆ<(//2:
*ꢑꢆ*5((1
5ꢑꢆ5('
%ꢏ%5ꢐ
*ꢏ<ꢒ*ꢐ
:ꢏ%/ꢐ
%/
B
:ꢑꢆ:+,7(
5
)$1
+(50
&$3$&,725
&2035(6625
:
0
&
&
:
6
+($7
3527(&725
%
%
ꢃ
5ꢏ
05
ꢐ
)$1ꢆ02725
0
3,3(7(03ꢀ
6(1625
+
0
/
ꢍ
Y
5
%/
ꢊ
75$16)250(5
ꢂ
&1ꢊ &1ꢍ
&1ꢇ &1ꢌ
7(03ꢀ
5220
6(1625
&1ꢂ
+,
&1ꢈ
&1ꢎ
/2:
%/
%/
12
&
NC
)86(ꢃ
7ꢂꢀꢃꢌ$
ꢊꢌꢄ9$&
1
&1ꢃꢃ
&1ꢃꢄ
'&)
)/2$7
6:,7&+
&21ꢃ
&1ꢃ
+80,',7<
6(1625
&21752/
ꢆ%2$5'
127(ꢑꢆ
ꢃꢆ%(&$86(ꢆ2)ꢆ',))(5(17ꢆ&2035(6625
7+(ꢆ3$57ꢆꢆꢆꢆ0$<ꢆ127ꢆ%(ꢆ86('ꢀ
ꢃ
ꢊꢆ%(&$86(ꢆ2)ꢆ',))(5(17ꢆ02'(/6
7+(ꢆ3$57ꢆꢆꢆꢆ0$<ꢆ127ꢆ%(ꢆ86('ꢀ
ꢊ
13
Download from Www.Somanuals.com. All Manuals Search And Download.
The End
DE45EM/DE65EM
Sincere Forever
Haier Group
Haier Industrial Park, No.1, Haier Road
Edited by: GuanLi
DingCheng
266101, Qingdao, China
E-mail: [email protected]
Tel: +86 532 88936935
Signed by:WangRuoFeng
Approved by: ZhangPeng
Factory Model NO. DE45EM/DE65EM
Some models may have an additional
letter after the model number.
Domestic Air Conditioner
Download from Www.Somanuals.com. All Manuals Search And Download.
|