Haier Air Conditioner AE122BCAAA H2EM 18H03 User Manual

Free Combination Multi-split Type  
Room Air Conditioner  
AE122BCAAA  
Contents  
(H2EM-18H03)  
Before Use  
Operation Points--------------------------1  
Name of Parts ----------------------2-3  
Safety Precautions---------------------4-5  
Operation Instruction  
Fan Operation-----------------------------6  
Auto, Cooling, Dehumidifying,  
Heating Operation---------------------7  
Timer On/Off Function---------------8  
Timer On-Off Function --------------9  
Sleep Function-----------------------10  
User's Attentions---------------------11  
Maintenace  
Maintenance--------------------------12  
Troubleshooting----------------------13  
Installation of Indoor Unit  
Installation Instruction----------14-16  
-
Installation Procedure ----------17-26  
No. 0010572805  
Please read this manual carefully before  
using  
Please keep this manual for future use  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Name of Parts  
Indoor unit  
Fan  
Motor  
Electric box  
Air outlet grille  
Evaporator  
Drain pan  
Wire controller  
Mode Fan Speed Swing  
Temperature  
AUTO  
Clock  
Timer  
Set  
Sleep  
**  
**  
Aux. Heat Fileter Reset  
Reset  
ON/OFF  
2
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Before starting the unit, please read the following ìSafety Precautionsî carefully to guarantee the normal  
operation of the system.  
The following lists two kinds of safety precautions ìWarningî and ìNoticeî. For the items that the improper  
use may cause death or serious injury are listed in ìWarningî volume. However, sometimes the items listed  
in ìNoticeî volume may also cause serious accidents. So, these two volumes are the important contents  
related to safety, they must be observed.  
Do equip with  
grounding wire  
Do follow the  
instruction  
Do not do like this  
After carefully reading this manual, please keep in hand for reference. If the air conditioner is given to a new user,  
this manual should be attached with unit to the new user.  
Installation Safety Precautions  
Warning  
The system should be applied to  
places as office, restaurant,  
residence and the like.  
The system should be installed by your  
dealer or a professional installer.  
Installation by yourself is not encouraged.  
Because improper installation could cause  
water leakage, electric shock and fire  
accident.  
Application to inferior environment  
such as workshop, it may cause  
equipment malfunction and serious  
injury or death.  
Notice  
Make sure the system is grounded.  
Drain pipe should be arranged  
A creepage breaker must be  
installed at the installation place  
properly to provide a smooth  
drainage.  
ON  
OFF  
Grounding wire should never be  
connected to gas pipe, city water  
pipe, lightning conductor rod or  
the telephone line. If the grounding  
wire is not set properly, it may cause  
Unless the circuit breaker is  
installed, it may cause  
electric shock.  
If the pipe is arranged improperly,  
furniture or the like may be  
damaged by the leaked water.  
Operation safety precautions  
Warning  
Do not let the cold wind blow to  
human body for a long time.  
When any abnormal condition (scorching  
smell or others) is found, stop operation  
immediately and turn off the power switch.  
Then consult your dealer.  
It may affect the physical condition  
or cause some health problems.  
If continuing the operation without removing the  
cause, it may cause trouble, electric shock or fire.  
Notice  
Do not handle switches with a wet hand.  
It may cause electric shock.  
Do not use water to clean the air conditioner.  
It may cause electric shock.  
4
Download from Www.Somanuals.com. All Manuals Search And Download.  
Safety Precautions  
Notice  
Do not put or use any spray  
The system should never be used for  
any other purposes than intended such  
as for preservation of food, flora and  
fauna, precision devices or work of  
art.  
Do not put the fire devices in  
the places, which the air from  
the air conditioner can directly  
blow.  
near the air conditioner, and  
do not directly spray to the  
air conditioner.  
Otherwise it may cause  
fire.  
It may cause the fire devices  
cannot burn completely.  
Itmaycausedeteriorationofthearticles.  
Do not install the system where the air  
outlet may directly reach the flora and fauna.  
Only use the proper specified fuse.  
If use metal wire  
or copper wire to replace the fuse, it  
may cause trouble and fire accident.  
It will not be good for their health.  
Do not use the power When operating the system When cleaning, please  
switch to turn of or off the  
air conditioner.  
stop the unit and cut off  
the power first.  
simultaneously with a combustion  
apparatus, indoor air must be ventilated  
frequently.  
ON  
Do not perform  
cleaning, when the  
indoor fan motor is  
rotating in high speed.  
OFF  
Insufficient ventilation may cause  
the danger of lack of oxygen.  
It may cause fire  
or Creepage.  
Do not put the water  
containers, such  
Do not use such equipment as  
awater heater, etc., around the  
indoor unit or the  
as vase, on  
the unit.  
wire controller.  
If the water enters into the unit  
and damages the electric  
insulation material,it may  
cause electric shock.  
If the system is operated at the vicinity of such  
equipment that generates steam, condensed water may  
drip during cooling operation or it may cause Creepage  
or short-circuit.  
Safety precautions when moving, reinstalling and repairing the air conditioner  
Warning  
When moving the air conditioner to another  
installation place, please contact the dealer  
or the professional installer.  
Do not refit the air conditioner. When repair  
is needed, please contact your dealer.  
Improper moving and reinstallation may  
cause water leakage, electric shock and  
fire accident.  
Improper repair may cause water leakage,  
electric shock and fire accident.  
5
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation instruction  
Fan operation  
Turn on the unit  
1
Press the ON/OFF button to turn on the  
unit The LCD display of the wire  
controller will show the previous  
working state (except for Timer, Sleep,  
Swing mode), the operation indicator  
light on the wire controller will light up.  
Fan Speed Swi ng  
Mode  
2
Temper at ur e  
3
Set  
Cl ock  
Ti mer  
Sl eep  
2
Choose of working mode  
Press MODE button, each press the working  
mode will change as the following sequence:  
AUTO COOLING DEHUMIDIFYING  
HEATING FAN,  
Aux. Heat  
Fi l et er Reset  
Reset  
4
ON/ OFF  
1
AUTO COOLING DEHUMIDIFYING HEATING FAN  
Choose FAN operation.  
3
Adjusting FAN SPEED  
Press the FAN SPEED button to change fan  
speed:  
LOW FAN MED FAN HIGH FAN  
LOWFAN MEDFAN HIGHFAN  
Choose the desired fan speed  
Turn off the unit  
4
Press the ON/OFF button to turn off the unit.  
The wire controller only shows the clock and  
room temperature.  
About FAN operation  
FAN operation refers the air conditioner does not perform COOLING and HEATING  
operation, but FAN operation. In this mode, the air conditioner cannot perform  
AUOT FAN operation, and does show the temperature value on the wire controller.  
6
Download from Www.Somanuals.com. All Manuals Search And Download.  
then choose AUTO, COOLING, DEHUMID  
IFYING, HEATING operation.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Operation instruction  
Timer On/Off function  
Before using TIMER function, calibrate the clock first (referring to page 3). When you wake up in  
the morning, before going back to home after work or after going to bed, you can let your air conditioner  
automatically turn on or turn off.  
1. Turn on the unit  
After turning on the unit, set the desired working mode.  
The LCD of the wire controller will show working mode.  
(except for Timer, Sleep, Swing)  
Fan Speed Swi ng  
Mode  
Temper at ur e  
2. Set of TIMER mode  
Press the TIMER button to change the TIMER mode,  
each press the TIMER mode will change as the following  
sequence:  
Set  
Cl ock  
Ti mer  
Sl eep  
**  
. Heat  
Fi l et er Reset  
Reset  
ON  
AM  
OFF  
ON  
OFF  
Blank  
AM  
PM  
PM  
ON/ OFF  
Timer Off Timer On-Off  
Timer On  
Then choose the timer mode as you need  
(TIMER ON or TIMER OFF.)  
At this time the ON or OFF will flash.  
3. Set time  
Press the time adjusting button  
Each press, the set time increases 10 minutes. If depress the button, the time will increase  
rapidly.  
Each press, the set time decreases 10 minutes. If depress the button, the time will decrease rapidly.  
This LCD will show the time set, the time can be adjusted within 24h.  
(AM stands for morning, PM stands for afternoon).  
4. Confirm the time  
After calibration of the clock, press SET button to confirm time.  
At this time, the ON or OFF will not flash.  
The time displayed is: at x oíclock x minutes the unit will be turned on  
(TIMER ON) or turned off (TIMER OFF).  
Cancel TIMER  
Press the TIMER button several times until the TIMER mode display  
disappears.  
Hints:.  
After power failure, the clock should be calibrated again.  
The wire controller has memory function, when you use this function  
for the second time, if the time set is the same as the previous one, you  
just need to choose the TIMER mode then press the SET button to confirm.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Timer On-Off function  
Operation instruction  
1.  
After turning on the unit,  
set the proper working mode  
The LCD of the wire controller  
will show working mode.  
**  
**  
**  
(except for Timer, Sleep, Swing)  
**  
2.  
Set of TIMER mode  
**  
**  
**  
**  
Press the TIMER button to change the TIMER  
mode, each press the TIMER mode will change  
as the following sequence:  
**  
6
5
**  
**  
**  
ON  
OFF  
ON  
OFF  
AM  
AM  
PM  
PM  
**/ **  
Then choose the TIMER ON-OFF mode.  
At this time the ON will flash.  
Set the TIMER ON time  
3.  
Press the time adjusting button  
Each press, the set time increases 10 minutes. If depress the button,  
the time will increase rapidly.  
Each press, the set time decreases 10 minutes. If depress the button,  
the time will decrease rapidly.  
The LCD shows the time set.  
It can be adjusted arbitrarily in 24 hours. (AM refers to morning,  
4. Confirm the time  
After adjusting time, press SET button to confirm time.  
At this time, the ON will not flash, OFF begins to flash.  
The time displayed is: at x oíclock x minutes the unit will be turned  
Set the TIMER OFF time  
5.  
Press the TIME button, the adjustment method is the same as  
the one of setting TIMER ON time.  
6.  
Confirm the time of TIMER OFF  
After adjusting time, press SET button to confirm time.  
At this time, the OFF will not flash.  
The time displayed is: at x oíclock x minutes the unit  
will be turned off.  
Cancel TIMER  
Press the TIMER button several times until the TIMER mode display disappears.  
According to the sequence of TIMER ON & TIMER OFF setting, you can realize  
turning on unit first, then turning off unit.  
9
Download from Www.Somanuals.com. All Manuals Search And Download.  
Sleep operation  
Operation instruction  
Before going to bed, you can press the SLEEP button, the air conditioner will operate  
in comfort sleep mode to make you have a sound sleep.  
Before using this function, you should calibrate the clock first, otherwise, the SLEEP  
function will be out of order.  
Use of SLEEP function  
After turning on the unit, setting the working mode, then press SLEEP button to  
make the air conditioner have the previous Sleep time (powered on for the first  
time or after performing Sleep is 1h). The Sleep symbol will appear. Press time  
/ button, you can choose between 1~8h. Each press, it may increase/decrease  
1h and will display in the humidity area with ì xhî , and display ì Timer Offî in  
Timer Off area and the time to turn off; press Sleep button again to cancel Sleep  
SLEEP operation stops  
SLEEP operation starts  
Operation modes  
1.In COOLING, DEHUMIDIFYING operation  
about 6 hours  
Increase 1  
*
1 hour later in SLEEP operation, the temperature  
will increase 1C from the set temperature, another  
1 hour later increase another 1C, then the unit  
will operate continuous for 6 hours, then it turns  
off automatically. The temperature is higher than  
set temperature to prevent you from getting a cold.  
1hour  
Increase 1  
*
1hour  
Set temperature  
turn off  
In COOLING and DEHUMIDIFYING operation  
Set temperature  
turn off  
1hour  
2.In HEATING operation  
Decrease2*  
1hour  
1 hour later in SLEEP operation, the temperature  
will decrease 2C from the set temperature, another  
1 hour later increase another 2C, then the unit  
will operate continuous at this temperature for 3  
hours, then it increases 1C, after operating at this  
temperature for another 3 hours, the unit  
will turn off automatically. The temperature is  
lower than set temperature to prevent you from  
feeling uncomfortable during sleep.  
Decrease2*  
About 3 hours  
Increase 1  
*
3 hours  
SLEEP operation stops  
SLEEP operation starts  
In HEATING operation  
Mode Fan Speed  
Temper at ur e  
Swi ng  
Set  
Cl ock  
Ti mer  
Sl eep  
3.In AUTO operation  
Set  
Fi l et er Reset  
Aux. Heat  
Reset  
The air conditioner will operate in the relative Sleep  
operation according to the operation mode.  
ON/ OFF  
4.In FAN operation  
SLEEP operation cannot be applied.  
Note:  
After setting Sleep function, it is not permitted to adjust clock.  
The Sleep time is less than 8h, after reaching the set time, the unit will automatically stop.  
Set Sleep function after setting ì Timer Offî function, the air conditioner will perform Sleep function.  
After setting Sleep function, the Timer function cannot be set.  
Set Sleep function after setting ì Timer Onî function, the Sleep function can only be set in the set time  
of Timer On.  
10  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Usersí Attention  
If do not use the air conditioner for a  
long time, it is necessary to cut off  
power.If do not cut off power, the unit  
may consume power. In order to protect  
the unit, before using  
Do not press tightly with the LCD part of  
the wire controller to avoid damage of it.  
Set proper room temperature  
Not too low or high and make every  
people in the room feel comfortable.  
the air conditioner  
Cut off  
power  
again, turning on  
the power at least  
Heating  
18-23*  
Cooling  
26-28*  
12 hours in advance.  
The windows should be hung with  
curtains or blinds.  
Do not let the cold air blows  
directly to human  
body for a long time  
and do not make the  
room temperature  
Do not let the sun  
shine directly shine  
in the room; do not  
let the outdoor air enter room.  
Otherwise, it may cause  
The articles must keep dry cannot  
be put under the  
uncomfortable or bad to your health.  
indoor unit.  
The room should  
often ventilate.  
After a long-time  
of using air  
conditioner, the  
room must be ventilated.  
When the humidity is  
over 80% or the drainage  
outlet is blocked, the  
Do not put articles around the air  
inlet and outlet.  
This kind of obstacle  
can lower the efficiency  
of the air conditioner  
As the character of Heat Pump air  
conditioner, the heating capacity will  
decrease with the outside temperature drops.  
In actual use, the difference of  
outdoor temperature, room size,  
room structure and direction will  
make the capacity and power  
consumption change of the unit.  
Do not keep the doors and  
windows open  
Otherwise, it may lower the  
efficiency of the air conditioner.  
Television, radio and acoustics, etc.  
equipment should keep  
over 1m from indoor  
unit and wire controller.  
Otherwise, they may  
The airflow cannot  
directly blow to the pets  
and plants.Otherwise,  
the petsand plants  
will be harmed  
disturb the image and cause noise.  
The air conditioner can only be  
used in air conditioning. It can  
not be used in other purpose.  
Do not use the air conditioner in  
some specific purpose,  
such as storage or prot  
ect food, animals,  
In actual installation, because of the  
influence of neighboring noise and  
reflection, the noise of the unit  
generally will be higher than the  
written value.  
Do not put any heating devices under  
the indoor unit.  
The heat may cause the  
deformation of indoor unit.  
plants, precise  
instrument and  
artwork, otherwise,  
the quality of them may be declined.  
11  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Maintenance  
When maintaining, do turn off the manual power switch.  
Daily cleaning  
Clean air conditioner and wire controller  
Use soft cloth to dry clean  
If there is too much dirt on the air conditioner panel,  
please soak the cloth with water, and then clean it.  
(The wire controller cannot use water to clean, it  
should use dry cloth to clean.)  
It is forbidden to use gasoline, diluent, eradicator  
powder and chemical dishcloth etc. to clean,  
otherwise it may cause deformation and crack.  
Maintenance after the using season  
In a sunny day and FAN mode, let the unit operate about half a day to make  
the inner part of the unit dry.  
Turn off the operation switch of the air conditioner, cut off the power switch.  
Otherwise, even the air conditioner is in OFF state, it will consume certain  
power.  
Clean the air filer and the system of indoor unit, wash and clean the outdoor  
unit, and use dustcoat to cover the unit.  
Maintenance before the using season  
Check if there are any obstacles in the air inlet and outlet  
of indoor and outdoor unit to avoid the working  
efficiency drop.  
Please do install the air filter and insure it is not dirty.  
Otherwise, the unit is damaged or has trouble due to  
Please check first  
the dust entry into the unit.  
In heating, in order to protect the compressor in starting the unit, please switch  
on the power switch of the unit 12 hours in advance before using it, and in  
using season, please always keep the power switch in ON state.  
12  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Troubleshooting  
Before as the special repair center for help, please check the following items of the air  
conditioner  
Symptom  
Hear the sound of  
water flow  
Cause  
The water flow sound when operation starts; during operation and shortly  
after operation stops, in 2-3 minutes shortly after the operation starts,  
sometimes the sound becomes louder. This is the sound of refrigerant flow  
and the draining sound of condensate water.  
In DEHUMIDIFYING,  
no air sent out or cannot  
change the fan speed.  
In DEHUMIDIFYING operation, when the room temperature is 2 C higher  
than the set temperature, despite of the set FAN SPEED the air conditioner  
will operate in LOW FAN SPEED.  
Because the smells generated by wall, carpet, furniture,clothes, cigarette  
and cosmetic, etc. attached on the air conditioner.  
Having peculiar smell  
in the out air  
In order to prevent the oil and refrigerant from resorting in the indoor  
unit, there is refrigerant flow in very short time, so they give out ì Sha,  
Shaî , ì Gulu, Guluî . Additionally, when the other indoor units perform  
HEATING operation, sometimes white vapor appears; when the other  
indoor units perform COOLING operation, cold air appears.  
The stopped indoor unit  
gives out sound, white  
vapor or cold air.  
If there is the following symptom and check they are the following causes,  
please solve them according to the below given methods.  
Symptom  
Causes  
Solution  
The fuse is blown out or the  
breaker is open-circuit.  
The unit does  
not work  
Change fuse or close breaker  
Once the unit starts,  
it stops immediately  
The air inlet or outlet of indoor and  
outdoor unit is blocked  
The air inlet or outlet of indoor  
and outdoor unit is blocked  
Improper set temperature  
The fan speed is set too low  
Remove the obstacle  
Remove the obstacle  
Abnormal  
COOLING or  
HEATING  
Refer to page 7  
Refer to page 7  
Close them  
Doors or windows are open  
Direct sunshine. (COOLING)  
Hang curtains or blinds before window  
Too much people in room (COOLING)  
Toomanyheatsourcesinroom(COOLING)  
Trouble Contents  
Code Displayed  
Indoor temperature sensor trouble  
F1  
F2  
F4  
Inner pipe coil sensor trouble (thin pipe)  
Inner pipe coil sensor trouble (thick pipe)  
High pressure trouble (pressure)  
Drainage trouble  
F5  
F6  
If after the above checking and treatment, the air conditioner still cannot work normally, or  
find the following phenomena, please stop the unit and contact the commissioned service  
center.  
The fuse or breaker is often blown out or open circuit.  
In COOLING or DEHUMIDIFYING, there is water leakage.  
Abnormal operation or abnormal sound be heard.  
The display screen of the wire controller shows trouble code indicating the unit has  
trouble.  
13  
Download from Www.Somanuals.com. All Manuals Search And Download.  
When Troubles Occur  
Before installing, do read this ì Safety precautionsî carefully to guarantee theproper installation.  
The below attentive matters are divided into ì Warningî and ì Noteî two parts. When the wrong  
installation occur, it is very possible death and severe injury and other serious accidents will happen.  
For those items are listed in ì Warningî part. But even the items listed in ì Noteî part can also  
cause serious accidents. Above all,both the two parts are very important contents related to safety,  
so they must be obeyed.  
After finishing the installation work, do test run to verify everything is normal. After that please explain  
the using and maintenance methods to the user. Additionally, give this installation manual and operation  
manual to the user and ask them to keep it properly.  
Warning  
The commissioned repair center shall do the installation work. If you do the installation work by  
yourself, the improper installation will cause water leakage, electric shock fire and other accidents.  
The installation work shall be in line with what the installation manual specified. If installation is not  
proper, water leakage, electric shock, fire and other accidents will occur.  
Install the air conditioner to a place where can definitely stand its weight. The air conditioner can  
not be installed on a nonmetal bracket (such as theft guard net). Places not firm enough will cause  
drop down of unit resulting in body hurt.  
The installation work shall be preventive to typhoon and earthquake. If the installation work is  
not met with the requirements, overturn of the unit will occur resulting in accidents.  
Using the specified cable to do wiring work and connecting firmly and properly. Fix the connecting  
part of the terminals to prevent it from the external force. Improper connection and fixing will cause  
heating and fire etc. accidents.  
Wiring shall be kept in correct shape avoiding extrusion. After installation, the electric box cover and  
the external panel shall not nip the wire. Improper installation will cause heating and fire etc. accidents.  
When setting or moving the air conditioner do not let the air and things alike get into the refrigeration  
system except the specified refrigerant (R22). If air and other things enter, abnormal high pressure  
will occur, which easily cause break and body injuries etc. accidents.  
When installing, do use the accessories or specified parts. If not using the parts specified  
by our company, water leakage, electric shock, fire and refrigerant leakage will occur.  
Do not lead the drain hose to drain where the sulfur gas may be involved. Otherwise,  
the poisonous gas will enter into the indoor.  
During installation, if refrigerant leakage occurs, do the ventilation work immediately.  
As soon as the refrigerant gas meets fire, poisonous gas will be produce.  
After installation, confirm there is no leakage of refrigerant. If the refrigerant gas enters into room  
and meet the air blowing heater, heater or stove etc. fire source, the poisonous gas may be produced.  
Do not install the unit in a place where the combustible gas may be leaked. In any case  
the combustible gas leaks and accumulated around the unit, fire accident will occur.  
The drain hose should be correctly installed according to the installation manual to ensure  
smooth drainage, and take proper heat preservation measure to prevent from dew.  
Improper pipe installation may cause water leakage result in wet the indoor articles.  
Do heat insulation work to the refrigerant gas pipes and liquid pipes to reach the purpose of heat  
preservation. If the heat insulation measure is not sufficient, water generated by condensing dew will  
drip leading to wet the floor and indoor articles.  
Notice  
Do grounding work. Do not connect the grounding wire to gas pipe, tap, lighting rod or  
telephone line. Improper grounding will cause electric shock.  
In some places the creepage breaker shall be installed. If do not install the breaker, electric  
shock may occur.  
After electric installation, power on them to do electric leakage test.  
14  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation instruction  
Notice  
This manual can not include all kinds of conditions, if you have new  
requirements and questions, please contact with local Haier Sales Center.  
Warning  
Before installing the unit, please read this manual carefully. Improper installati  
on may cause accidents and make unit damage or death.  
Installation tools  
1. Screwdriver  
2. Steel saw  
3. 60mm 70mm diameter drill  
5. Spanner (14, 17, 19, 27mm)  
7. Pipe flarer  
4. Spanner (diameter 17,27mm)  
6. Pipe cutter  
8. Knife  
9. Pincers  
11. Tape measure  
10. Leakage detector/soap water  
12. Scraper  
Standard accessories  
The following parts mentioned in this manual are self-provided installation parts.  
A
B
C
D
E
F
Mark  
Pipe  
supportin  
g plate  
Nonbibulous  
thermal insulation  
material  
Connection  
pipe  
Name  
of parts  
Adhesive  
tape  
Plaster  
powder  
Drain hose  
Accessories attached with the unit  
The following lists the accessories attached with the unit, please use them according  
to the installation needs.  
NO.  
2
1
3
4
6
5
Thermal  
insulation pipe  
Wire controller  
Manual  
Gasket  
Signal wire  
Wire clamp  
Shape  
&
name  
**  
**  
**  
A
U
T
O
**  
**  
**  
**  
**  
**  
**  
**  
****  
**  
**/ **  
Amount  
1
8
*
1
2
1
15  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation instruction  
1. Installation of Duct  
1)Duct material  
Type  
Material  
Structural characteristic  
Main use  
Normal thin steel  
Good processing performance and structural hardness  
Good anticorrosive performance  
Generally used in ventilation duct system  
Storm protection system in  
ventilation engineering  
Galvanize steel  
Good processing performance, corrosion resistant,  
uneasily sparkle  
Aluminum orits alloy  
Stainless steel  
Anti-corrosive ventilation  
Anticorrosive, acid-resistant  
engineering in chemical industry  
Aluminum foil soft  
metal duct  
Widely used  
Soft with compression resistant, simple installation  
with vibration resistance  
Sprayed a layer of 0.2~0.4mm plastic on the normal  
thin steel  
Air conditioning system needing  
good dust protection and anti-  
corrosive system under 10~70*  
Plastic compound steel  
Applicable to the ambient condition  
of 0*60 *, ventilation system  
with corrosion of acid gas  
Stiff PVC plastic  
Anti-corrosive, glazed surface, easy production  
With light, high intensity, noncombustible,  
Anti-corrosive, glazed surface, easy  
anti-corrosive, high temperature resistant characteristic production  
Glass fibre reinforced  
plastic  
2) Sectional shape of duct (mainly has rounded and rectangular two shapes)  
a
Rect angul ar duct  
Rounded duct  
d
b
a
b
R=2. 5d  
R*3/ 2b  
3) Connecting mode  
The dimension of rectangular duct is the same as the air outlet of indoor unit,can be directly connected; the rounded  
duct needs to be added with a static pressure box to connect with the air sending outlet of indoor unit; independently  
introduced to respective distributor by rounded duct. In order to meet the requirements of room air conditioner,  
the fan speed in each air outlet of any distributor shall be adjusted to basically the same.  
3
Air volume(m/h)  
Air volume-static pressure graph of duct type unit  
4) Installation parameter  
200  
100  
700  
Diameter of dut*mm)  
Rectangular  
H( mm)  
L( mm)  
duct  
800  
*
Out unit static pressure (Pa)  
*
*
30  
1- 2  
*
*
*
*
*
*
Number of duct outlet  
Duct length (m)  
*
*
*
*
*
*
a
*
*
*
4
600  
*
*
b
40/ 38/ 36  
Noise dB(A)  
*
2
Recommendedapplicablearea(m)  
14*25  
25  
c
400  
Partial resistance of distributor(Pa)  
Resistance along duct (Pa/m)  
1. 2  
Static pressure  
value(Pa)  
Air volume-static pressure of duct type unit  
5
10  
15  
20  
25  
30  
0
Static pressure(Pa)  
Air  
0
5
10  
15  
20  
25  
30  
3
Cutline  
volume(m/h)  
Speed  
High speed  
a
*
*
High speed  
Medium speed  
Low speed  
788 763 740  
669 642 615  
543 519 480  
716  
587  
463  
687  
567  
442  
663  
538  
418  
632  
512  
390  
b
c
Medium speed  
Low speed  
*
16  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install indoor unit  
Installation procedure  
Notice  
!
Do not install the air conditioner at the place where  
the combustible gas maybe leak. In case of the leaked  
gas gather around the unit, it may cause fire accident.  
The indoor unit should be installed in the place where the cool air and warm air may  
evenly circulate.  
Avoid the following places:  
Place with too much salinity (coastal area).  
Place with too much sulfuration gas (mainly is the hotspring area,  
the copper pipe and brazed part are easily corroded).  
Place with too much oil (including mechanical oil) and vapor.  
Place using organic solvent.  
Place with machines may generate high frequency electromagnetic waves.  
(The control system may have abnormality)  
Place near the doors or windows that come close to the external high humidity  
air. (may easily form dew)  
Place where the special sprayer may be frequently used.  
On vehicles, boats and ships.  
Place less than 1m away from TV, radio, radio devices and fluorescent lamp.  
Indoor unit  
1. Choose the place where the air from the air conditioner can spread  
throughout the room and where the connection pipe, connection wire  
and drain hose may be easily arranged to the suitable outdoor position.  
2. Choose the place where the vertical distance between the center of air  
outlet and the ground is no more than 2.7m.  
3. The structure of the ceiling should be firm enough to bear the weight of the unit.  
4. The connection pipe, drain hose and connection wire can penetrate  
through the wall and connect indoor and outdoor unit.  
5. The connection pipe and drain hose between indoor and outdoor unit  
should be as short as possible.  
6. The connection flare should be provided by user.  
Safety precautions  
1. For those models with electric heat function, it is forbidden to directly  
connect the air outlet with canvas and material alike inflammable interfaces.  
2. When installing indoor unit, it is necessary to leave a checking hole for  
convenient repair.  
17  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation procedure  
Install indoor unit  
When install the duct hidden type indoor unit, the return air box must be  
designed and installed, as Figure 1, Figure 2.  
The distance between the air outlet of duct and the air outlet of air  
conditioner should be no more than 1m (when the out unit static pressure is 0Pa).  
Low static pressure duct type: max static pressure is 30Pa.  
Buildingroofofinstallation  
*1m  
A
Ceiling  
(Figure 1)  
Unit  
Return air box  
Air out duct  
Return air  
Air supply  
Air ourlet girlle  
There should be  
no obstacles  
Air supply  
Return air box  
(Figure 2)  
Unit  
Return air  
M8 wide expansion screw bolt  
M8 hoisting screw  
A amplified  
(Figure 3)  
Unit  
M8 wide lock washer  
M8 screw nut  
Air supply passage  
C
B
(Figure 4)  
C amplified  
B
B amplified  
B Rivet  
Use screw to  
fix top panel  
Top panel of unit  
Air supply passage  
Air supply passage  
Air outlet grille  
19  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install indoor unit  
Installation procedure  
Install the hoisting screw  
Use M8 or M10 hoisting screw (4, prepare on site) (When the height of hoisting  
screw is more than 0.9m, you must use M10), their gaps refer to the dimension  
of air conditioner, according to the original structure and the following method  
to install.  
wood structure  
Put up the frame wood on the beam and mount the hoisting screws.  
Frame wood  
Beam  
Hoisting screw  
New cement panel  
Use embedded parts and foot screw, etc to mount.  
Iron  
Foot screw  
(Knife type embedded part) (Louver type embedded part)  
(hoisting foot screw for connection pipe)  
Original cement panel  
Use the in hole hinge, in hole  
plug or in hole screw.  
Steel structure  
Suspending bolt  
Directly use angle steel or new angle  
steel for support.  
Hoisting screw  
Angle steel for support  
Suspending of indoor unit  
Fix the cap of hoisting screw on and suspend them on the T groove  
of the hoisting part of the unit.  
Use gradienter to keep the level degree of the unit within 5mm.  
20  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation procedure  
Install indoor unit  
Notice  
*
In order to normally drain water, the drain hose should be mated according to the  
installation manual. In order to avoid dew-forming, thermal insulation treatment  
should be done.Improper connection pipe may cause water enter indoor.  
Requirements:  
The indoor side drain hose should be thermal insulated.  
The parts connected with indoor unit should be thermal insulated. Improper  
thermal insulation may cause dew-forming phenomenon.  
The drain hose should be downwards slant (over 1/100) and there  
should be no S-shaped bend. Otherwise, abnormal sound may occur.  
The horizontal length of the drain hose should be less than 20m. If the  
connection pipe is too long, the supporting frame should be set every  
1.5~2m to prevent pipe from rise and fall.  
For the centralized connection pipe, please perform work as the following Figure shown.  
Pay attention not to exerting external force to the connection part of the drain hose.  
1. 5m*2m  
Supporting frame  
As large as possible (about 10cm)  
S-shaped bend  
Downward slant over 1/100  
VP30  
Downward slant over 1/100  
Thermal insulation material  
user self-provided)  
wall  
outside  
Slant  
Drain hose (user self-provided)  
Material of connection pipe and thermal insulation  
Material of connection pipe  
Material of thermal insulation  
Stiff PVC pipe VP 20mm (inside diameter)  
Foam polyethylene pipe, thickness over 10mm  
Confirm drainage  
Perform test run to insure the condition of drainage, the connection part of the connection  
should not leak water. The confirmation must be performed even if install in winter.  
21  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Install indoor unit  
Installation procedure  
!
warning  
During installation, if refrigerant leakage occurs, please immediately take ventilation measure.  
If the refrigerant gas meet the fire, it may generate poisonous gas.  
After finishing installation work, please make sure there is no refrigerant leakage. If the leaked  
refrigerant gas meet heater and oven, etc. fire sources, it may generate poisonous gas.  
Permitted length and fall of connecting pipe  
Depending on the outdoor units, for details, please refer to the attahed manual of outdoor unit.  
Material and dimension of connecting pipe  
Material of connecting pipe  
Phospor deoxy copper seamless pipe used in air conditioner (TP2)  
Gas side  
12.7  
6.35  
Dimension of connecting pipe  
( mm)  
Liquid side  
Two spanners operation  
Connection of refrigerant pipe  
Perform connection of flared pipe to connect all the refrigerant pipes.  
The connection of indoor unit connecting pipe must be performed by  
two spanners.  
For installation torque, please refer to the following table.  
External diameter of  
conneting pipe(mm)  
Installation torque (N.m)  
Tightening torque (N.m)  
11. 8( 1. 2kgf . m)  
49. 05( 5. 0kgf . m)  
13. 7(1. 4kgf. m)  
53. 9(5. 5kgf. m)  
6. 35  
12. 7  
22  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation procedure  
1. Connection of pipe  
Connection of pipe  
Connection method  
The connecting pipe max length of KRD-32N is 15m, and the max fall between indoor and outdoor unit is 5m;  
the connnecting pipe max length of KDR-70N is 50m, the max fall between indoor and outdoor unit is 30m.  
The max fall between two indoor units in one system is 10m.  
Nut  
Joint  
In order to guarantee the efficiency, the pipe should be  
as short as possible.  
Spanner  
Daub the refrigerant oil on the joint and the flared nut.  
When bending the pipes, give the roundness as large  
as possible, to avoid crashing the pipes.  
Spanner  
To connect the pipe, fit the center and use hand to screw  
the nut, then use spanner to tighten the nut, as shown in figure.  
Pay attention not to let alien matters, such as  
sand, vapor get into the pipe.  
The connection of indoor unit pipe must be  
performed by using two spanners.  
If do not fit the center and screw the  
nut hard, the screw thread may be  
damaged, which will cause  
refrigerant leakage.  
2.The additional charging amount of refrigerant  
The additional charging of refrigerant (R22) should be complied with the installation manual  
of outdoor unit. It must use measurer to quantificationally charge. The a dditional charging  
amount must be complied with the specified amount.Requirements: Both excessive charging  
and less charging of refrigerant will cause the compressor trouble. It must be complied with  
the specified amount.  
3. For discharging, please refer to outdoor unit  
4.Leakage detection  
Use leakage detector or soap water to check if the connected part of the  
connection pipe and the valve cap leak.  
5.Thermal insulation treatment  
The thermal insulation of connection pipe should be performed at both gas side and  
liquid side. In COOLING, both liquid side and gas side are in low temperature, in  
order to prevent dew from forming, thermal insulation should be done.  
The thermal insulation material at the gas side must use the material with the heat  
resistant temperature over 120 C.  
The connected part of indoor unit connection pipe should be thermal insulated.  
The cut upward  
(Attached Figure)  
On-site connection pipe side  
Indoor unit  
Accessorial thermal insulation pipe  
23  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation procedure  
Electric wiring  
Note:  
All the wires should be copper core wires.  
The power cable of indoor unit should be equipped according to the operation manual of indoor unit.  
Before finishing vacuumizing the refrigerant pipe system, do not supply power to indoor unit.  
When connecting the indoor & outdoor wire, check the number of the indoor & outdoor terminals, the  
terminals with the same number connected together with same one wire.  
Incorrect wiring will damage the controller of the air conditioner or make the unit work abnormally.  
The air conditioner must use special power circuit and special air switch (40A), groundign wire. The  
wiring work should be done by a qualified electrician according to the national wiring rule.  
The creepage breaker must be installed. The grounding line and the null line of the receptacle must be  
strictly separated. It is incorrect to connect the null line with the grounding line.  
The connection type of power cord is Y connection. If the soft power cord is damaged, to avoid risk,  
it must be replaced by the manufacturer or their specific repair department or similar professional worker.  
Wiring method  
1.The wiring method of orbicular terminal  
For the connection wire which end is orbicular  
terminal, its wiring method is as the right figure  
shown. Dismantle the screw and put it through the  
The wiring method of orbicular terminal  
ring at the end of the connection wire, then connect  
it to the terminal block and tighten the screw.  
Correct pressing  
Wrong pressing  
2.The wiring method of straight terminal  
For those connection wires whose end are  
Terminal block  
not orbicular terminals, their wiring method  
is:Loosen the connecting screw, insert the  
Wireholdingclamp  
end of the wire directly into theterminal  
block, and then tighten screw. Pull the wire  
(Sketch map)  
outwards slightly to confirm it is held tightly.  
3.Pressing method of connection wire:  
After wiring, the connection wire must be pressed with wire holding clamp. The  
wire holding clamp should press on the out cover of the connection wire. As the  
right figure shown:  
The indoor and outdoor unit shall respectively use special power circuit.  
The indoor units connected with the same outdoor unit, its creepage breaker and switch shall be  
connected to the same power circuit.  
The communication wire of indoor and outdoor unit is 2-core twisted-pair with polarity. (as right  
figure shown)  
The indoor and outdoor unit shall respectively use special power circuit.  
P
P
P
P
1 2 3 4  
Q
Q
Q
Q
Outdoor unit 1PH, 220V~,50Hz  
OK  
NO  
24  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation procedure  
Install wire controller  
****  
1. Remove the upper cover of wire controller  
*****  
The PC board is installed on the back cover of  
wire controller. When remove the upper cover,  
pay attention not to damage PC board.  
**  
*****  
2. Install wire controller  
Drill 2 wall holes according to the position of the 2 screw holes on the back cover of wire controller,  
then hit wood in the wall holes. Put the 2 screw holes on the back cover of wire controller properly to  
its corresponding wood, then use wood screws to fix the back cover on the wall.  
Note:  
Install the back cover of wire controller on the even wall as possible as can. When tightening  
the wood screw, do not use to tight force, otherwise the wire controller may be damaged.  
Switch  
Mark ON  
OFF  
Inverter  
Fixed frequency  
1
2
3
4
Note:  
When connecting wire, please keep  
a certain distance between signal  
wire and electric wire. (over  
10mm)  
Have rise and drop  
Swing  
No rise and drop  
No Swing  
The collection temperature  
of panel  
The collection temperature  
of main panel  
Under this series, the switch is set as:  
1.ON 2. OFF 3. OFF 4.OFF  
Dimension of signal wire:  
Type of wire  
Shield wire (4 cords)  
3. Indoor unit wire connection  
0. 33 mm 2  
Dimension  
Connect the terminals (A, B, C, D,) on the wire  
controller to the terminals on the indoor PC panel  
(A, B, C, D,) respectively.  
The connection between indoor  
unit and wire controller and  
indoor unit and outdoor unit  
should use shield wire. And the  
two ends of the shield wire  
should be grounded, otherwise,  
the disturbance will cause unit  
abnormal operation.  
Arrange wire from this part  
AB  
CD  
Back cover  
wire controller  
Upper cover of  
wire controller  
Shield wire  
Grounded  
Note:  
Confirm the connection part of terminals is firm and will not touch shield wire.  
4. Cover the wire controller upper cover  
Pay attention not to press the connection wire.  
Note: Do not touch PC board by hand.  
25  
Download from Www.Somanuals.com. All Manuals Search And Download.  
Installation procedure Other instruction and test  
Other instruction  
Set of the air sending of the fan motor  
Before leaving factory, the rotation speed of fan motor has already been set at standard choice.  
When the indoor unit uses free air sending and not needing to connect with duct, the fan speed  
of indoor unit is set at standard choice. When the indoor unit needs to connect with duct, please  
according to the following figure shown to change the connection of the connector installed on  
the side of electric box.  
The relative relation between  
fan speed and static pressure  
Standard air sending  
(Before leaving factory)  
High fan speed air sending  
Control box side  
Control box side  
Unit: Pa  
Standard  
Connector(White)  
White  
High fan speed  
Connector(White)  
Red  
fan speed  
0
30  
Fan motor side  
Fan motor side  
Cut and flaring method  
Use pipe cutter to cut the pipe, the  
burrs must be removed.  
After inserting the flarer,  
perform flared nut.  
Connecting pipe  
Liquid pipe  
Gas pipe  
Dimension  
Pipe diameter  
A( mm)  
6. 35mm(  
1
/
4")  
0.8~1.5  
1.0~1.0  
12. 7mm( 1/ 2")  
Incorrect  
Correct  
Flarer  
A
Slant  
Broken  
Burrs Uncompleted Too long  
The following items must be noticed carefully during installation.  
After finishing installation, performing checking.  
After installing the refrigerant pipe, drain hose and electric wire properly,  
perform test run to ensure the system not have trouble.  
Test run  
It is necessary the installer perform the test run for one time  
to check if the unit works normally.  
26  
Download from Www.Somanuals.com. All Manuals Search And Download.  

Graco Inc Paint Sprayer 233700 User Manual
Gravely Barcode Reader 927060 RM1028 User Manual
Greenheck Fan Ventilation Hood FSD 331 User Manual
Groupe SEB USA T FAL Coffeemaker 8819 User Manual
Hasbro Games EKara User Manual
Hasbro Games Giggle Game User Manual
Heat Controller Universal Remote B SMA SMH09 12 18SC User Manual
Hotpoint Ventilation Hood KSO89CX S User Manual
Hubbell Work Light SM 24 User Manual
IDEAL INDUSTRIES Boiler CXSi 110 User Manual