DUCT TYPE AIR CONDITIONER
Operation manual
Installation manual
AD842AHEAA
AU84NATEAA
No. 0150504624 B
Please read this operation manual before using the air conditioner.
Please keep this manual carefully and safely.
Download from Www.Somanuals.com. All Manuals Search And Download.
Cautions
Disposal of the old air conditioner
Before disposing an old air conditioner that goes out of use, please make sure it's inoperative and safe. Unplug the air
conditioner in order to avoid the risk of child entrapment.
It must be noticed that air conditioner system contains refrigerants, which require specialized waste disposal. The valuable
materials contained in a air conditioner can be recycled. Contact your local waste disposal center for proper disposal of
an old air conditioner and contact your local authority or your dealer if you have any question. Please ensure that the
pipework of your air conditioner does not get damaged prior to being picked up by the relevant waste disposal center,
and contribute to environmental awareness by insisting on an appropriate, anti-pollution method of disposal.
Disposal of the packaging of your new air conditioner
All the packaging materials employed in the package of your new air conditioner may be disposed without any danger to
the environment.
The cardboard box may be broken or cut into smaller pieces and given to a waste paper disposal service. The wrapping
bag made of polyethylene and the polyethylene foam pads contain no fluorochloric hydrocarbon.
All these valuable materials may be taken to a waste collecting center and used again after adequate recycling.
Consult your local authorities for the name and address of the waste materials collecting centers and waste paper disposal
services nearest to your house.
Safety Instructions and Warnings
Before starting the air conditioner, read the information given in the User's Guide carefully. The User's Guide contains very
important observations relating to the assembly, operation and maintenance of the air conditioner.
The manufacturer does not accept responsibility for any damages that may arise due to non-observation of the following
instruction.
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier.
Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's
Guide.
For the purpose of safety, the air conditioner must be properly grounded in accordance with specifications.
Always remember to unplug the air conditioner before opening inlet grill. Never unplug your air conditioner by pulling on
the power cord. Always grip plug firmly and pull straight out from the outlet.
All electrical repairs must be carried out by qualified electricians. Inadequate repairs may result in a major source of
danger for the user of the air conditoiner.
Do not damage any parts of the air conditioner that carry refrigerant by piercing or perforating the air conditioner's tubes
with sharp or pointed items, crushing or twisting any tubes, or scraping the coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result in serious eye injuries.
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet
and swing louver.
Do not allow children to play with the air conditioner. In no case should children be allowed to sit on the outdoor unit.
2
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
Before starting to use the system, read carefully this"SAFETY PRECAUTIONS" to ensure a proper operation of the system.
Safety precautions described here are classified to " WARNING" and " CAUTION". Precautions which are shown
in the column of " WARNING" means that an improper handing could lead to a grave result like a death, serious injury,
etc. However, even if precautions are shown in the column of " CAUTION", a very serious problem could occur depending
on situation. Make sure to observe these safety precautions faithfully because they are very important information to ensure
the safety.
Symbols which appear frequently in the text have following meanings.
Strictly prohibited.
Observe instructions faithfully.
Provide a positive grounding.
When you have read through the manual, keep it always at hand for read consultation. If the operator is replaced, make
sure to hand over this manual to the new operator.
CAUTIONS FOR INSTALLATION
WARNING
The system should be applied to places as office, The system should be installed by your dealer or When you need some optional devices such as a
restaurant, residence and the like.
a professional installer.
humidifier, electric heater, etc., be sure to use the
products which are recommended by us. These
devices should be attached by a professional
installer.
Installation by yourself is not encouraged because
it could cause such problems as water leakage,
electrical shock or fire accident by some improper
handing.
Installation by yourself is not encouraged because
it could cause such problems as water leakage,
electrical shock or fire accident by some improper
handing.
Application to inferior environment such as an
engineering shop, could cause equipment
malfunction and serious injury or death.
CAUTION
Do not install nearby the place where may have Depending on the place of installation, a circuit
leakage of flammable gas. breaker may be necessary.
Drain pipe should be arranged to provide a positive
draining.
ON
OFF
If the gas leakes and gathers around, it may cause Unless the circuit breaker is installed, it could
the fire. cause elecrical shocks.
If the pipe is arranged improperly, furniture or the
likes may be damaged by leaked water.
Where strong winds may prevail, the system should Install on the place where can endure the weight Make sure the system is grounded.
be fixed securely to prevent a collapse.
of air conditioner.
Bodily injury could result by a collapse.
Bodily injury could result by a careless installation. Grounding cable should never be connected to a
gas pipe, city water pipe, lightning conductor rod
or grounding cable of telephone. If the grounding
cable is not set properly, it could cause electric
shocks.
CAUTIONS FOR TRANSFER OR REPAIR
WARNING
Modification of the system is strictly prohibited. When the system needs a When the air conditioner is relocated, contact your dealer or a professional
repair, consult your dealer. installer.
Improper practice of repair could cause water leakage, electric shock or fire. Improper practice of installation could cause water leakage, electric shock
or fire.
3
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
CAUTIONS FOR OPERATION
WARNING
You should refrain from exposing your body directly Do not poke the air inlet or outlet with a bar, etc. When any abnormal condition (scorching smell or
to cool wind for a long time.
others) is found, stop the operation immediately
and turn off the power switch. Then consult your
dealer.
If you continue the operation without removing the
It could affect your physical condition or cause Since the internal fan is operating with a high cause, it could result in a trouble, electric shock
some health problems.
speed, it could cause an injury.
or fire.
CAUTION
The system should never be used for any other Do not handle switches with a wet hand.
purposes than intended such as for preservation
of food, flora and fauna, precision devices or work
of art.
Combustion apparatus should not be placed
allowing a direct exposure to wind of air conditioner.
It could cause deterioration of food or other problems. It could cause electric shocks.
Incomplete combustion could occur on the apparatus.
Make sure to use a fuse of proper electric rating.
Do not wash the air conditioner with water.
Do not install the system where the air outlet
reaches directly the flora and fauna.
Use of steel or copper wire in place of a fuse is
strictly prohibited because it could result in a trouble
or fire accident.
It could cause electric shocks.
It will not be good for their health.
Neither stand on the air conditioner nor place It is strictly prohibited to place a container of
something on it. combustible gas or liquid near the air conditioner is removed.
or to spray it directly with the gas or liquid.
Do not operate the system while the air outlet grill
There are risks of falling or injury by collapsed object. It could cause a fire accident.
There is a risk of injury.
Do not use the power switch to turn on or off the Do not touch the air outlet section while the swing Do not use such equipment as a water heater, etc.
system.
louver is operating.
around the indoor unit or the wire controller.
ON
OFF
If the system is operated at the vicinity of such
equipment which generates steam, condensed
water may drip during cooling operation or it could
cause a fault current or short-circuit.
It could cause a fire or water leakage.
There is a risk of injury.
When operating the system simultaneously with Check occasionally the support structure of the Do not place any objects on or climb on the unit.
a combustion apparatus, indoor air must be
ventilated frequently.
unit for any damage after a use of long period of
time.
If the structure is not repaired immediately, the
unit could topple down to cause a personal injury.
Insufficient ventilation could cause an oxygen
deficiency accident.
When cleaning the system, stop the operation
and turn off the power switch.
Do not put water containers on the unit such as a Do not try to repair or reconstruct by yourself.
flower vase, etc.
If the water enters into the unit and damages the
electric insulation material, it may cause electric
shock.
Cleaning should never be done while the internal
fans are running with high speed.
4
Download from Www.Somanuals.com. All Manuals Search And Download.
Safety Precautions
The machine is adaptive in following situation
1. Applicable ambient temperature range:
Maximum:
Minimum:
32 C / 23 C
18 C / 14 C
D.B / W.B
D.B / W.B
Indoor
Cooling
Heating
Maximum:
Minimum:
D.B / W.B
D.B
43 C / 26 C
15 C
Outdoor
Indoor
Maximum:
Minimum:
D.B
D.B
27 C
15 C
Maximum:
Minimum:
D.B / W.B
D.B / W.B
24 C / 18 C
-7 C / -8 C
Outdoor
2. If the supply cord is damaged, it must be replaced by the manufacturer or its service agent or a similar qualified person.
3. If the fuse on indoor unit PC board is broken, please change it with the type of T. 3.15A /250V.
If the fuse on outdoor unit PC board is broken, please change it with the type of T. 6.3A /250V.
4. The wiring method should be in line with the local wiring standard.
5. The power cable and connecting cable are self-provided.
The power cable should be 5G 6.0mm2 .
The connecting cable should be 4G 1.5mm2.
All the cables shall have got the European authentication certificate. During installation, when the connecting cables
break off, it must be assured that the grouding wire is the last one to be broken off.
6. The breaker of the air conditioner should be all-pole switch; and the distance between its two contacts should be no
less than 3mm.
7. The indoor unit installation height is at least 2.5m.
NOTE:
Installation and maintenance must be meet the local installation and maintenance instructions and should operate by the
experienced special installation and maintenance technicians. Otherwise we dont take any duty of the units damage or
injure to the person caused by improper operation.
WARNING!
1.The sharp edges and corners and coil surface have the danger to injury. Please avoid of them.
2.Its very danger to remove the units and power supply wire, because it can cause injury and death. Cut off all the power
supply before maintenance.
5
Download from Www.Somanuals.com. All Manuals Search And Download.
Parts and Functions
Indoor Unit
Air outlet
Duct
Duct
Drain pipe
Air inlet
Outdoor Unit
Air outlet
Air inlet
Air inlet
6
Download from Www.Somanuals.com. All Manuals Search And Download.
Heating Mode
"HOT KEEP" function
"HOT KEEP" is operated in the following cases.
When heating is started:
In order to prevent blowing out of cool wind, the indoor unit fan stopped according to the room temperature which heating
operation is started. Wait for approx. 2 to 3 minute, and the operation will be automatically changed to the ordinary heating
mode.
Defrosting operation (in the heating mode):
When it is liable to frost, the heating operation is stopped automatically for 5 to 12 minutes once per approx. one hour,
and defrosting is operated. After defrosting is completed, operation mode is automatically changed to ordinary heating
operation.
When the room thermostat is actuated:
When room temperature increases and room temperature controller actuates, the fan speed is automatically
changed to stop under low temperature condition of indoor heat exchanger. When room temperature
decreases, air conditioner automatically changes over to ordinary heating operation.
Warming Operation
Heat pump type warming
With the heat pump type warming, the mechanism of heat pump that concentrate heat of outdoor air with the help of
refrigerant to warm the indoor space, is utilized.
Defrosting operation
When a room is warmed with a heat pump type air conditioner, frost accumulates on the heat exchanger of outdoor unit
along with the drop of indoor temperature. Since the accumulated frost reduces the effect of warming, it is necessery to
automatically switch the operation to the defrosting mode. During the defrosting operation, heating operation is interrupted.
Atmospheric temperature and warming capacity
Warming capacity of heat pump type air conditioner decreases along with the drop of outdoor temperature.
When the warming capacity is not sufficient, it is recommended to use another heating implement.
Period of warm-up
Since the heat pump type air conditioner employs a method to circulate warm winds to warm
the entire space of a room, it takes time before the room temperature rises.
It is recommendable to start the operation a little earlier in a very cold morning.
7
Download from Www.Somanuals.com. All Manuals Search And Download.
Care and Maintenance
Points to observe
Do not touch with wet hand.
Turn off the power supply switch.
Do not use hot water or volatile liquid.
Do not
ON
Thinner
use!
Benzine
Tooth powder
OFF
CAUTION
Do not open the inlet grill until fan stops completely.
Fan will continue rotating for a while by the law of inertia after operation is being stopped.
Clean the air filter
1.Clean the air filter by lightly tapping it or with the cleaner. It is more effective to clean the
air filter with water.
If the air filter is very dirty, dissolve neutral detergent in the lukewarm water (approx. 30 C),
rinse the air filter in the water, and thoroughly wash the air filter off the detergent in the plain
water.
2. After drying the air filter, set it up on the air conditioner.
CAUTION
Do not dry the air filter with fire.
Do not run the air conditioner without the air filter.
Care and Cleaning of the unit
Clean with soft and dry cloth.
If it is very dirty, dissolve neutral detergent in the lukewarm water and make the cloth wet with the water.
After wiping, clean off the detergent using clean water.
Post-Season Care
Operate the unit with FAN mode on a fair day for about half a day to dry the inside of the unit well.
Stop operation and turn off the power supply switch. Electric power is consumed even the air conditioner is in stop.
Clean the air filter and set it in the place.
Pre-Season Care
See that there are no obstacles blocking the air inlet and air outlet of both indoor and outdoor units.
Make sure that the air filter is not dirty.
Cut in the power supply switch 12 hours before starting run.
8
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Please check the following things about your air conditioner before making a service call.
Unit fails to start
Is the power source switch Is city supply power in normal? Isn't the signal receiving
Isn't the earth leakage breaker
section exposed to the direct in action?
sunlight or strong illumination?
adjust cut in?
ON
It is dangerous. Turn off the
power supply switch
immediately and contact the
sales dealer.
OFF
Power
stoppage?
Power supply switch is not ON.
Cooling or heating is not sufficient
Is the thermostat adjust as
required?
Isn't the air filter dirty?
Isn't any doors or windows
left open?
Doesn't any obstacle exist at
the air inlet or outlet?
Isn't the swing louver horizontal? (At HEATING mode)
If swing louver is horizontal, the blow wind does not reach floor.
Cooling is not sufficient
Isn't sun-shine invading direct? Isn't any unexpected heating Isn't the room much crowded? The wind does not blow during
load generated?
heating operation
Isn't it warming up?
When the air conditioner does not operate properly after you have checked the above mentioned items or when the following
phenomenon is observed, stop the operation of the air conditioner and contact your sales dealer.
The fuse or breaker often shuts down.
Water drops off during cooling operation.
There is a irregularity in operation or abnormal sound is audible.
When the CHECK lamp (red) flickers, an irregularity has occurred in the air conditioner.
Note:
This unit has a function of automatic restart system after recovering power stoppage. Please contact the sales dealer if it
is not required.
9
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
The followings are not malfunction
Water flowing sound is heard.
When the air conditioner is started, when the compressor starts or stops during
operation or when the air conditioner is stopped, it sometimes sounds "shuru shuru"
or "gobo gobo". It is the flowing sound of the refrigerant, and it is not a trouble.
Shuru
Shuru
Cracking sound is heard.
It smells.
This is caused by heat expansion or contraction of plastics.
Air which blows out from the indoor unit sometimes smells. The smell results from
residents of tobacco smoke or cosmetics stuck inside of unit.
During operation, white fog comes When the air conditioner is used at restaurant etc. where dense edible oil fume always
out of indoor unit.
exists, white fog sometimes blows out of air outlet during operation.
In this case consult sales dealer for cleaning the heat exchanger.
It is switched into the FAN mode To prevent frost from being accumulated on the indoor unit heat exchanger, it is
during cooling.
sometimes automatically switched to the FAN mode but it will soon return to the cooling
mode.
The air conditioner can not be
restarted soon after it stops.
Even if the operation switch is turned on, cooling, dehumidifying or heating is not
operable for three minutes after the conditioner is stopped. Because the protecting
Wait for
circuit is activated. (During this time air conditioner operates in fan
Unit does
not start
three
minutes
mode.)
Air does not blow or the fan speed When it is excessively cooled during dehumidifying, the blower automatically repeats
can not be changed during
dehumidifying
reducing and lowering the fan speed.
During operation, operation mode Isn't the AUTO mode selected?
has changed over automatically. In the case of AUTO mode, operation mode is changed automatically from cooling
to heating or vise-versa according to the room temperature.
Water or steam generates from
the outdoor unit during heating.
This results when frost accumulated on the outdoor unit is removed
(during defrosting operation).
10
Download from Www.Somanuals.com. All Manuals Search And Download.
Troubleshooting
Diagnosis for On-Off models
shows resumable fault, shows it is not resumable fault.
11
Download from Www.Somanuals.com. All Manuals Search And Download.
Precaution for Installation
Safety precautions
Please read these "Safety Precautions" first then accurately execute the installation work.
CAUTION
,
WARNING
Though the precautionary points indicated herein are divided under two headings,
those points which are related to the strong possibility of an installation done in error resulting in death or serious injury
are listed in the section. However, there is also a possibility of serious consequences in relationship to the
and
WARNING
points listed in the CAUTIONsection as well. In either case, important safety related information is indicated, so by all
means, properly observe all that is mentioned.
After completing the installation, along with confirming that no abnormalities were seen from the operation tests, please
explain operating methods as well as maintenance methods to the user (customer) of this equipment, based on the owner's
manual. Moreover, ask the customer to keep this sheet together with the owner's manual.
WARNING
This system should be applied to places as office, restaurant, residence and the like. Application to inferior environment
such as engineering shop could cause equipment malfunction.
Please entrust installation to either the company which sold you the equipment or to a professional contractor. Defects
from improper installations can be the cause of water leakage, electric shocks and fires.
Execute the installation accurately, based on following the installation manual. Again, improper installations can result
in water leakage, electric shocks and fires.
When a large air-conditioning system is installed to a small room, it is necessary to have a prior planned countermeasure
for the rare case of a refrigerant leakage, to prevent the exceeding of threshold concentration. In regards to preparing
this countermeasure, consult with the company from which you perchased the equipment, and make the installation
accordingly. In the rare event that a refrigerant leakage and exceeding of threshold concentration does occur, there is
the danger of a resultant oxygen deficiency accident.
For installation, confirm that the installation site can sufficiently support heavy weight. When strength is insufficient,
injury can result from a falling of the unit.
Execute the prescribed installation construction to prepare for earthquakes and the strong winds of typhoons and
hurricanes, etc. Improper installations can result in accidents due to a violent falling over of the unit.
For electrical work, please see that a licensed electrician executes the work while following the safety standards related
to electrical equipment, and local regulations as well as the installation instructions, and that only exclusive use circuits
are used.
Insufficient power source circuit capacity and defective installation execution can be the cause of electric shocks and
fires.
Accurately connect wiring using the proper cable, and insure that the external force of the cable is not conducted to
the terminal connection part, through properly securing it. Improper connection or securing can result in heat generation
or fire.
Take care that wiring does not rise upward, and accurately install the lid/service panel. Its improper installation can
also result in heat generation or fire.
When setting up or moving the location of the air conditioner, do not mix air etc. or anything other than the designated
refrigerant (R410A) within the refrigeration cycle.
Rupture and injury caused by abnormal high pressure can result from such mixing.
Always use accessory parts and authorized parts for installation construction. Using parts not authorized by this company
can result in water leakage, electric shock, fire and refrigerant leakage.
CAUTION
Execute proper grounding. Do not connect the ground wire to a gas pipe, water pipe, lightning rod or a telephone ground
wire. Improper placement of ground wires can result in electric shock.
The installation of an earth leakage breaker is necessary depending on the established location of the unit. Not installing
an earth leakage breaker may result in electric shock.
Do not install the unit where there is a concern about leakage of combustible gas.
The rare event of leaked gas collecting around the unit could result in an outbreak of fire.
For the drain pipe, follow the installation manual to insure that it allows proper drainage and thermally insulate it to prevent
condensation. Inadequate plumbing can result in water leakage and water damage to interior items.
12
Download from Www.Somanuals.com. All Manuals Search And Download.
Is the Unit Installed Correctly
Confirm the following items for safe and comfortable use of air conditioner.
The installation work is to be burden on the sales dealer, and do not conduct it by yourself.
Installation place
Avoid installing the air conditioner near the Install the unit at well ventilated place. Install the air conditioner firmly on the
place where possibility of inflammable gas
leakage exists.
foundation that can fully support the weight
of the unit.
Air outlet
Air inlet
Air inlet
If some obstacle exist, it may cause
capacity reduction or noise increase.
Explosion (Ignition) may occur.
If not, it may cause vibration or noise.
Select the place so as not to annoy
neighbor with the hot air or noise.
Snow protection work is necessary
where outdoor unit is blocked up
by snow.
It is advisable not to install the air con-
ditioner at the following special place.
It may cause malfunction, consult the
sales dealer when you have to install
the unit on such a place.
For details consult your sales dealer.
The place where corrosive gas
generates (Hot spring area etc.)
The place where salt breeze blows
(Seaside etc.)
The place where dense soot smoke
exists
The place where humidity is extraordina-
rily high
The place where near the machine
which radiates the electromagnetic wave
The place where voltage variation is
considerably large
Electric work
The electric work must be burden on the authorized engineer with qualification for electric work and grounding work, and
the work must be conducted in accordance with electric equipment technical standard.
The power source for the unit is to be of exclusive use.
An earth leakage breaker should be installed.(This is necessary to prevent electric shock.)
The unit must be grounded.
When you change your address or the installation place
Special technology is required for removal or reinstallation of air conditioner, consult the sales dealer.
Besides, construction expense is charged for removal or reinstallation.
For inspection and maintenance
The capacity of air conditioner will decrease by contamination of inside of unit when it is used for about three years although
depending upon the circumstances under which it is used, and so in addition to the usual maintenance service, special
inspection/maintenance service is necessary. It is recommended to make a maintenance contract (charged) by consulting
your sales dealer.
13
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Indoor Unit
NOTE
All Wiring of this installation must comply with NATIONAL, STATE AND LOCAL REGULATIONS. These instructions
do not cover all variations for every kind of installation circumstance. Should further information be desired or should particular
problems occur, the matter should be referred to your local distributor.
WARNING
BE SURE TO READ THESE INSTRUCTIONS CAREFULLY BEFORE BEGINNING INSTALLATION. FAILURE TO FOLLOW
THESE INSTRUCTIONS COULD CAUSE SERIOUS INJURY OR DEATH, EQUIPMENT MALFUNCTION AND/OR
PROPERTY DAMAGE.
1. Before installation (Before finishing installation, do not throw the attached parts installation needs)
Confirm the way to move the unit to the installation place.
Before moving the unit to the installation place, do not remove their packages. When having to remove the package, use
a soft material or protection board with rope to lift the unit assembly to avoid unit damage or bumping a scrape.
2. Selecting the installation place
(1) The chosen installation place should meet the following requirements and get the users consent.
Place ensures ideal airflow distribution.
The passage of airflow has no obstacles.
When importing outside air, it should be imported directly from outdoors. (if the pipe can not be extended, it also can not
be imported from top)
Place ensures enough space for maintenance.
The pipe length between indoor and outdoor unit is in the permitted limit (referring to outdoor unit installation part).
The indoor unit, outdoor unit, electric wire and connection wire is at least 1m away from television and radio. This is to
avoid the image disturbance and noise caused by the above-mentioned home appliance. (Even if 1m away, if the
electromagnetic wave is too strong, it can also cause noise.)
(2) The height of ceiling
The indoor unit can install on the ceiling, which height is no more than 3m.
(3) Install and use the hoisting screw. Check if the installation place can bear the weight of unit assembly. If not
certain, strengthen it before install the unit.
Over 100
Air out
Over 900
Checking meatus
(600x600)
Air in
Ceiling
14
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Indoor Unit
3. Preparation before installation
(1) The position relation among hoisting screw (unit: mm)
1700
1510
360
250
Down side
Up side
1510
(2) If necessary, cut the opening installation and checking needed on the ceiling. (If has ceiling)
Before installation, finish the preparation work of all the pipes (refrigerant, drainage) and wire (wire controller connection
wire, indoor and outdoor unit connection wire) of indoor unit, so that after installation, they can be immediately connected
with outdoor unit.
Cut the opening on the ceiling. Maybe it needs to strengthen the ceiling to keep the ceiling even and flat and prevent the
ceiling from vibration. For details, please consult to the builder.
(3) Hanger bolts installation
Use care of the piping direction when the unit is installed.(Use M10 screw
bolt)
Hole-in anchor
Hole-in plug
Insert
In order to bear the weight of the unit, for existed ceiling, using foundation
screw bolt; For new ceiling, using burying embedded screw bolt, burying
screw bolt or spot supplied other parts.
Concrete
Before going on installation, adjust the gaps with ceiling.
Hanging bolt M10
4. Installing indoor unit
Hanging bolt
Fix the indoor unit to the hanger bolts.
If required, it is possible to suspend the unit to the beam, etc. Directly by use
of the bolts without using the hanger bolts.
M10 nut
M10 washer
Note
M10 spring washer
Main unit
When the dimensions of main unit and ceiling holes does not match, it can
be adjusted with the slot holes of hanging bracket.
Adjusting to the levelness
(a)
Adjust the out-of levelness using a level or by the following method.
Make adjustment so that the relation between the lower surface of the unit
proper and water level in the hose becomes as given below.
Piping side
Supply water
Water level
(b)
Unless the adjustment to the levelness is made properly, malfunctioning or
failure of the float switch may occur.
0~5 mm
(0~0.2")
PVC hose
Bring the piping side slightly lower
15
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Indoor Unit
5. Drain Piping
(a)
Drain piping should always be in a downhill grade (1/50~1/100) and avoid riding across an elevation or making traps.
Good piping
Improper piping
Suspension
bolts
1.5m ~ 2m
Avoid riding across an elevation
Keep free from traps
Air vent
Do not pipe under water
A downhill grade
of 1/100 or more
Heat
insulation
Stage
(b)
(c)
When connecting the drain pipe to unit, pay suffcient attention
not to apply excess force to the piping on the unit side. Also,
fix the piping at a point as close as possible to the unit.
difference
Drain hose
part
Drain socket
Drain socket
Pipe cover(large)
[for insulation]
(accessory)
VP-25 joint
(field purchased)
Main unit
For drain pipe, use hard PVC general purpose pipe VP-
25(I.D.1") which can be purchased locally. When
connecting, insert a PVC pipe end securely into the drain
socket before tightening securely using the attached drain
hose and clamp. Adhesive must not be used connection of
the drain socket and drain hose (accessory).
VP-25
(field purchased)
Drain hose
(accessory)
Clamp
(accessory)
Adhesion Pipe cover [for insulation]
(field purchased)
Pipe cover(small) [for insulation]
(accessory)
(d)When constructing drain piping for several units, position the
common pipe about 100 mm below the drain outlet of each
unit as shown in the sketch. Use VP-30(11/4") or thicker pipe
for this purpose.
Secure the elevation as high as possible (approx. 100 mm)
VP-30
A downhill grade of 1/100 or more
(e)The stiff PVC pipe put indoor side should be heat insulated.
(f) Avoid putting the outlet of drain hose in the places with irritant gas generated. Do not insert the drain hose directly into
drainage, where the gas with sulfur may be generated.
(g)Set a backwater bend in the middle of drain hose as figure
shown.
Because the drain spout is at the position, which negative
pressure may occur. So with the rise of water level in the drain
pan, water leakage may occur. In order to prevent water
leakage, we designed a backwater bend.
The structure of backwater bend should be able to be cleaned.
H1=100mm or the static pressure of
air sending motor
H2=1/2H1 (or between 50~100mm)
As the right figure shown, use T type joint. The backwater
bend is set near the air conditioner.
Drainage Test
(1) Conduct a drainage test after completion of the electrical work.
(2)
During the trial, make sure that drain flows properly through the piping and that no water
leaks from connections.
In case of a new building, conduct the test before it is furnished with the ceiling.
Be sure to conduct this test even when the unit is installed in the heating season.
(3)
(4)
Procedures
Supply about 1000 cc of water to the unit through the air outlet using a feed water pump.
Check the drain while cooling operation.
(1)
(2)
16
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Indoor Unit
6. Installation of air suction and discharging duct
Please consult the after-sales service personnel for the choosing and installation of suction inlet, suction duct, discharging
outlet and discharging duct. Calculating the design drawing and outer static pressure, and choose the discharging duct
with proper length and shape.
muffler cavity (air sending)
Enlarging chart of profile chart A
Sacking joint
Insulation
A
Air volume adjuster
Air conditioner
main unit
Checking meatus
Ceiling
Air outlet
Vibration resistance hook
Air suction grille with air filter
The length difference among every duct is limited below 2:1.
Reduce the length of duct as possible as can.
Bad example
Bad example
Good example
Reduce the amount of bend as possible as can.
Use heat insulation material to bind and seal the part connecting main unit
and the flare part of air discharging duct. Perform duct installation work,
before the fitment of ceiling.
7. Calculation method of the dimension of the simple quadrate air duct
Presuming the unit length friction impedance of the duct is 1Pa/m, when
the dimension of one side of the air duct is fixed as 250mm, as shown
below:
A
Air conditioner
A
AD842AHEAA
B
A
Static pressure Equipped with
Air volume
Duct
box
air filter (bought)
A
B
2400m3/h(40m3/min)
600m3/h(10m3/min)
250x560(mmxmm)
250x190(mmxmm)
The calculation of duct resistance (the simple calculation is as follow table)
Straight part
Bend part
Calculate as per 1m length 1Pa, 1Pa/m
Each bend takes as a 3~4m long straight duct
Calculate as 25Pa
Air out part
Static pressure box
Calculate as 50Pa/each
Air inlet grille (with air filter) Calculate as 40Pa/each
The chosen chart of simple duct
Note:1Pa/m=0.1mmAg/m
Shape
Item
m3/h(m3/n)
1,800(30)
2000
Square duct
Shape Square duct
Item
Dimension
(mmxmm)
Air volume
Dimension
(mmxmm)
Air volume
m3/h(m3/n)
100
200
300
400
500
600(10)
800
250 x 60
250 x 90
250 x 430
250 x 470
250 x 560
250 x 650
250 x 740
250 x 830
250 x 920
250 x 1000
250 x 1090
250 x 1180
250 x 120
250 x 140
250 x 170
250 x 190
250 x 230
250 x 270
250 x 310
250 x 350
250 x 390
2400
3,000(50)
3,500
4,000
4,500
5,000
5,500
1,000
1,200(20)
1,400
1,600
6,000(100)
17
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Indoor Unit
8. The attentive matters in installation of air suction and discharging duct
Special air discharging outlet
Recommend to use anti-frost and sound-absorbing duct. (locally bought)
The duct installation work should be finished before the fitment of ceiling.
The duct must be heat insulated.
Use screw bolt to fix
The specific air-discharging outlet should be installed at the place where the
airflow can be reasonably distributed.
Duct
The surface should leave a checking meatus for checking and maintenance.
Air
Air
9. The examples of improper installation
Do not use air in duct and take the ceiling inner side instead. The result is
because of the irregular outer air mass, strong wind and sunshine, the humidity
is increased.
There may be water drop on the outside of duct. For cement and other new
constructions, even if not taking ceiling inner side as duct, the humidity will
also be so high. At this time, use glass fiber to perform heat preservation to
the whole. (use iron net to bind the glass fiber)
Maybe exceeding the unit operation limit (for example: when indoor dry bulb
temperature is 35 C, wet bulb temperature 24 C), it may lead to overload of
compressor.
Affected by the capacity of air discharging fan, the strong wind in the outer
duct and wind direction, when unit air sending volume exceeds the limit, the
discharged water of heat exchanger will overflow, leading to water leakage.
Air discharging fan
Improper example
11. Refrigerant pipe
The air side pipe, liquid side pipe must be faithfully heat insulated, if no heat insulation, it may cause water leakage.
The outdoor unit has been charged with refrigerant.
When connect the pipe to the unit or dismantling the pipe from the unit, please follow the figure shown, use spanner
and torque spanner together.
When connect cone nut, the inner side and outside of cone nut should paste with refrigerant oil. Use hand to twist 3-4
rings, then fasten with spanner.
Referring to Table I to confirm the fasten torque. (too tight may damage nut leading to leakage)
Check if the connection pipe leaks, then do heat insulation treatment, as below figure shown.
Only use seal cushion to bind the joint part of air pipe and heat insulation parts.
Paste the refrigerant oil here
Torque spanner
Middle size seal cushion (accessory)
Table I
(Use seal cushion to
bind the pipe joint)
Cone
dimension
A (mm)
Specification Tighten torque
of pipe
Cone
Clamp
R0.4~0.8
Heat insulation (accessory)
12.7mm
50 N.m
1.2~2.0
(for liquid pipe)
Spanner
A
Heat insulation (accessory)
(for gas pipe)
Pipe joint
Cone nut
Gas pipe
Liquid pipe
80
510
Liquid pipe
Gas pipe
Electric box
Upper
Air inlet
Air outlet
Down side
530
Drain hose connection mouth
VP25 PVC pipe
18
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Outdoor Unit
1. Selecting the installation place
Warning
It should be installed at places where it is firm enough to withstand the weight of the air conditioner to prevent falling.
Typhoon and earthquake prevention. It should be installed according to specific requirements. Inappropriate installation
may lead to accidents.
Dimension of outdoor unit
1000
660
750
660
Installtion space
Blow out
(1)During installation, connect the outdoor unit and align the mounting surface
(See the figure on the right). Mount the electric distribution device on the
external side of the unit in accordance to the installation instructions for
electric distribution device.
Absorb in
Absorb in
Absorb in
Working, repair surface
(2)To ensure good performance of the machine and facilitate installation and
maintenance, adequate space must be reserved (See figure on the right).
>300mm
>1000mm
(front side)
>20mm
>20mm
>20mm >20mm
Note:
Obstacles should be 2000mm off the top of the outdoor unit. Obstacles nearby
should be 400mm lower than the top of the unit.
A vertical view of the outdoor unit
2. Delivery of outdoor unit
Wire rope
Protection cushion
As there is no protective package for the outdoor unit, so the following points
merit attention:
(1)When forklift is used, insert the fork into the holes in the base plate.
(2)When crane is used, lift the unit with 4 pieces of steel rope with diameter
above 6 mm.
(3)Put protective materials between the cable and the unit to prevent deformation
and damage of the surface.
Base panel
Wire rope
19
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Outdoor Unit
3. Mounting outdoor unit
(1)The distance between two connections must not be less than 20mm.
Refer to the following figure for the distance between the foundation bolts.
20mm
20mm
20mm
1100
Through hole(15x20)
M12 foot screw bolt
4 screws each unit
(2)When the refrigerant pipe is connected from the bottom of the unit, the unit
should be raised at least 500mm(see the figure right)
Refrigerant tube
(3)In snowy regions, snow-proof facilities should be used (see the figure right).
(Poor snow-proof facilities may lead to damage.To avoid inconveniences, the
unit should be raised and snow-proof covers should be installed at the air
inlet and outlet.)
Air inlet snow-
proof cover
Air outlet snow-
proof cover
Air inlet snow-proof cover
(4)During installation, anti-vibration rubber pads should be used between the
machine and the bracket.
20
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Outdoor Unit
4. Connection of refrigerant pipe
Warning
During installation, if refrigerant leakage occurs, ventilation measures must be taken. When refrigerant meets with fire,
hazadous gas will be produced.
After installation, make sure that there is no refrigerant leakage. Refrigerant, if meeting with heaters and stoves, ect. in
the room, may produce hazardous gas.
Connection of refrigerant pipe
(1)The joints of the refrigerant pipe are inside the unit. Take off the access
hole cover in front of the unit.
(2)The pipe can be connected from the front or bottom of the outdoor unit.
Tube fixing
panel
M6
(3)Remove the L-shaped pipe from the valve by welding and connect the
M4
accessory pipe to the valve.
Base plate
T
Access hole cover
(4)In the case of front connection, cut the accessory pipe at the height of the
fixing panel. Then join the pipe with an elbow and let it go through the fixing
panel. For the convenience of maintenance, bend the pipe down (once) and
then connect pipe to the right or left.
(5)In the case of bottom connection, join the pipe with accessory pipe through
the holes in the base plate of the outdoor unit, and connect pipe the left or
right or the back.
ube to the back
ube to the tight
T
ube to the tight
T
ube to the left
T
ube to the left
T
(6)During welding, the gas pipe valve must be cooled down with a wet cotton cloth.
(7)The maximum connnection pipe is 50 meters, the maximum drop difference between indoor unit and outdoor unit is 30
meters.
(8)It should install the liquid check-ring and accumulator according to the outdoor unit and indoor unit position.(see the
following figures)
Fig.1 Outdoor unit below the indoor unit.
Fig. 2 Outdoor unit is above the indoor unit
Liquid check-ring
indoor unit
outdoor unit
Accumulator ( a set
per 6 meters)
outdoor unit
indoor unit
During welding of the distribution pipe
(1).In case of brazing weld of joint, nitrogen must be filled in the pipe to prevent oxidization.
(2).The refrigerant pipe should be newly-made and clean. During installation, do not let water and other substance into the pipe.
(3).Use two spanners to tighten the connecting nut. One spanner will make loose connection.
(4).The torque moment should conform to the specified value. (Refer to the below)
Torque moment for tightening the nut
Torque moment for
tightening up (N.m)
Torque moment for
pre-installation (N.m)
Tube diameter (mm)
12.70
.
.
53.9(5.5kgf m)
49.0(5.0kgf m)
5. Outdoor unit pipelines connection
According to the pipeline connection method, connect the distribute pipes and inlet & outlet liquid pipes.
21
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Outdoor Unit
6. Leak Test
Leak test must be made after connection of the refrigerant pipe according to the following diagram.
Close all the gas and liquid valves.To prevent nitrogen gas from invading the outdoor circulating system, close the valve
tightly before pressure increase,(Both the gas and liquid valves must be tightly closed.)
Every cooling system must be charged slowly from the gas and liquid valves.
It must be charged from the gas and liquid valves.
Note:
Never use oxygen, flamable and poisonous gases for the leak test.
Low-pressure gauge High-pressure gauge
Three-way valve fully closed
(gas side)
VL VH
Indoor
Outdoor
Gauge distributor
Tightly
closed
Solder
joint
Solder joint
Access hole
Copper pipe
6.4
Tightly
closed
Tightly
closed
Solder joint
Relief valve
Access hole
6.4
Copper pipe
Indoor unit
Outdoor unit
Three-way valve fully closed
liquid side
Detailed diagram of the three-way valve
(Gas side )access hole
To the gauge distributor
(Gas side)three-way valve
(Liquid side)access hole
To the unit
(Liquid side)three-way valve
Field tube
installation
Field tube
installation
(1)Pressurize for more than 3 minutes under 0.3MPa(3.0kg/cm2g)
(2)Pressurize for more than 3 minutes under 1.5MPa(15kg/cm2g). Serious leakage may be found.
(3)Pressurize for more than 24 hours under 3.0MPa(3.0kg/cm2g). Small leakage may be found.
Check if the pressure decrease
If the pressure does not decrease, then the test passes.
If the pressure decrease, check for leakage.
There will be a 0.01MPa(0.1kg/cm2g) pressure change for every 1 C ambient temperature change during the 24-hour
pressure charge. It should be corrected during the test.
Check for leakage
In the case of pressure decrease during steps (1) to (3), check the joints with the ear, hand or soapsuds for leakage. Repair
it by welding or tighten the connecting nut up.
22
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Outdoor Unit
7. Pipe Vacuumizing
Use vacuum pump to evacuate the air. Never use the refrigerant for the evacuation.
Drain off the nitrogen gas after the leak test and then connect the vacuum pump as shown in the figure below.
The vacuum pumping must be done from both the liquid and gas inlets.
Low-pressure gauge High-pressure gauge
Three-way valve fully closed
(gas side)
VL VH
Indoor
Tightly
Outdoor
Gauge distributor
6.4Copper pipe
6.4Copper pipe
Access hole
Solder
joint
closed
Solder joint
P
Tightly
closed
Tightly
closed
Vacuum pump
Solder joint
Access hole
Indoor unit
Outdoor unit
Three-way valve fully closed
liquid side
Detailed diagram of the three-way valve
(Gas side) access hole
To the gauge distributor
(Gas side) three-way valve
(Liquid side)access hole
To the unit
(Liquid side)three-way valve
Field tube
Field tube
installation installation
Use a vacuum pump with high degree of vacuum(below-755mmHg) and large volume displacement (above 40L/min).
The pumping time depends on the length of the connecting pipe. Generally, it takes about 2-3 hours. Make sure that the Y-shaped
valves on both the gas and liquid sides are closed before pumping.
If the vacuum can no reach-755mmHg within 2 hours, continue pumping for another 1 hour.
If the vacuum can no reach-755mmHg after more than 2 hour's pumping, close the valves VL and VH on the gauge distributor
and stop pumping. One hour later, check the vacuum again. If the vacuum has changed, it means there is a leakage. Repair it.
After the above steps, replace the vacuum pump with the refrigerant pump and refill refrigerant.
23
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Outdoor Unit
8. Refrigerant charge
After finished vacuum the system, change the vacuum to the refrigerant pump, charging the refrigerant.
Calculation of the the refrigerant charge
When the unit ships out of the factory, charge the refrigerant not including the construction procedure charged parts.
The calculation of the refrigerant charging:
When the connection pipe (L) <=5 meters, not need to add refrigerant ;
When the connection pipe (L) >5 meters, we need recharge the 100g refrigerant per add 1 meter.
That is, the quantity of refrigerant charging=(L-5)¡`100(g)
Refill refrigerant
When the outdoor valve is shut, fill the refrigerant from the access hole at the gas and liquid sides.
If the required filling is impossible, open all the gas and liquid valves, then slightly shut the gas valve, run the compressor
and fill the refrigerant from the access hole at the gas side. Now adjust the gas valve to control the refrigerant flow, which
will be gasified during absorption by the system.
If there is insufficient refrigerant in the system caused by leaks, refill it after the remaining refrigerant is recollected.
Open all valves
Open all the valves of the outdoor unit.
Heat isolation of the pipes
Separate isolation should be made for the liquid and gas pipes.
Materials used for the pipe isolation at the gas side must withstand above 120 C temperature.
Calculation of refrigerant density
Calculation will be made according to the following methods:
(1)Total refrigerant content of each system (kg) = content of 1 outdoor system + refilled refrigerant
Content of 1 outdoor system: Factory filled refrigerant
Refilled refrigerant: Filled content during installation according to the diameter and length of the liquid piping.
(2)Calculation of the minimum room sapce (m3).
(3)Calculation of refrigerant density
Total refrigerant content
Minimum room space
Refrigerant density: 0.3(kg/m3)
Preventive measures against excess of critical value
(1) Make ventilation holes
Ventilation holes should be built above and under the door. The area of each
hole should not be smaller than 0.15% of the room space. Holes can be made
directly in the wall.
(2) Reduce the filling content of refrigerant
Ventilation fan and gas leak alariming device
By shortening the distance between the indoor and outdoor units, filling content
of refrigerant can be reduced.
By reducing the capacity of the outdoor unit.
When outdoor unit be made up of several units, the outdoor capacity of each
system should reduce. So the refrigerant content of system reduce.
(3) Install ventilation fans.
The gas leak alarming
Users can install uninterrupted ventilation fans to keep the refrigerant density
device should be
under the critical value.
installed at refrigerant
gas stagnation areas
If uninterrupted ventilation is impossible,a combined fanning and alarming
device should be installed in its stead (through which immediate ventilation
is possible when leak occurs). (See the figure Right)
An example
24
Download from Www.Somanuals.com. All Manuals Search And Download.
Installation Precedure
Electrical Wiring
WARNING
DANGER OF BODILY INJURY OR DEATH
TURN OFF ELECTRIC POWER AT CIRCUIT BREAKER OR POWER SOURCE BEFORE MAKING ANY ELECTRIC
CONNECTIONS.
GROUND CONNECTIONS MUST BE COMPLETED BEFORE MAKING LINE VOLTAGE CONNECTIONS.
Precautions for Electrical wiring
Electrical wiring work should be conducted only by authorized personnel.
Do not connect more than three wires to the terminal block. Always use round type crimped terminal lugs with insulated
grip on the ends of the wires.
Use copper conductor only.
Selection of size of power supply and interconnecting wires.
Select wire sizes and circuit protection from table below. (This table shows 20 m length wires with less than 2% voltage drop.)
Power source
wire size
Circuit breaker
Earth leakage breaker
Switch Leak
breaker(A) current(mA)
Item
Phase
3
Switch breaker
Overcurrent protector
rated capacity (A)
(minimum)
Model
(A)
(mm2)
AU84NATEAA
40
30
6.0
40
30
Wiring connection
Make wiring to supply power to the outdoor unit, so that the power for the indoor unit is supplied by terminals.
Connecting cable and power cable are self-provided.
Indoor unit
terminal block
1
1
2
2
3
3
Y/G
Power supply
380-400V, 3N~, 50Hz
Outdoor unit
terminal bolck
L1 L2 L3 N
25
Download from Www.Somanuals.com. All Manuals Search And Download.
Download from Www.Somanuals.com. All Manuals Search And Download.
HAIER GROUP
Qingdao Haier Air Conditioner Electric Co., Ltd.
Address: Haier Garden, Qianwangang Road, Economic Development Zone,
Qingdao, Shandong 266500, P.R.China
Download from Www.Somanuals.com. All Manuals Search And Download.
|